Skip to main content

A prototype public docket site for the Connecticut Public Utilities Regulatory Authority

Utility Dockets and Filings

Compilations of discovery responses

Files31

Search terms highlighted
Eversource rate increase is on 144 pages across 21 files of the text below, highlighted. Go to the first matchClear highlighting
Words on different pages
15 pages match
Words on different pages

Text of ALLCO Set 3_COMBINED.pdf

Extracted from the file · 23 pages · 55,777 characters

Text of ALLCO Set 2_COMBINED.pdf

Extracted from the file · 38 pages · 81,182 characters

Words on different pages
  1. Page 12 of 27

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set ALLCO-01 Date Issued August 20, 2026 ALLCO-010 Page 1 of 1 Date Filed: September 04, 2026 Witness: Brendan J. O’Brien and Garrett J. Murray Request from: ALLCO Question: State the Test Year and projected Rate Year costs of administering the Company’s Connecticut distributed generation interconnection program (including employee and contractor headcount and costs, and any allocations from Eversource Energy Service Company or from Burns & McDonnell or other third-party project management vendors), and identify where those costs appear in the proposed revenue requirement. Response: Please refer to the table below which shows the Test Year and projected Rate Year O&M expenses associated with administering the Company’s Connecticut distributed generation interconnection program including employee and contractor costs and where they appear in the Company’s cost of service. Description Labor Outside Services/Other Admin Costs Total Schedule C-3.5 Payroll C-3.16 Field Ops – OH Lines Test Year $616,047 $640,960 Rate Year $660,100 $682,263 $1,257,007 $1,342,362
  2. Page 13 of 27

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set ALLCO-01 Date Issued August 20, 2026 ALLCO-011 Page 1 of 3 Date Filed: September 04, 2026 Witness: Lavelle A. Freeman, Juan F. Martinez, and Steven C. Osuch Request from: ALLCO Question: Produce the "preliminary analysis" referenced in Exhibit CLP-TSP-3 at 144 supporting the proposed "Avg. Interconnection Fee: < $500/kW," and the workpapers supporting the prospective SHARE fees of $392/kW (Tracy 14M group), $308/kW (Frybrook 13B group), and $192/kW (Campville 14R group) and the associated total distribution investment estimates of $180 million, $30 million, and $65 million (Exhibit CLP-TSP-3 at 146-149). Response: The high-level planning estimates were produced utilizing historical project and unit costs for the preliminary anticipated scopes of these projects. As the SHARE program is a proposed concept, at this time, specific impact studies have not been completed, no level engineering has been performed, and therefore estimates are not available with any more detail than provided in this response. Following PURA’s approval of the SHARE program and the proposed projects, engineering studies would be conducted to develop more detailed scopes and estimates, and project benefits, costs, viability and constructability would evaluated during our internal capital project review and approval process. The SHARE fee represented in the testimony was produced with the following formula: 𝑆𝑆𝑆𝑆𝑆𝑆𝑆𝑆𝑆𝑆 𝐹𝐹𝐹𝐹𝐹𝐹 𝑖𝑖𝑖𝑖 $/𝑘𝑘𝑘𝑘 = Total DER Customer Benefit Upgrade Cost in $M 𝑥𝑥1000 Estimated Enabled Commercial DER Capacity in MVA where 1000 represents the combined unit conversion of Millions of Dollars to Dollars and MVA to kW: $1,000,000 $1000/𝑘𝑘𝑘𝑘 = 1000 kW In these calculations, kW and MW are used synonymously with kVA and MVA given the typical unity power factor of inverter-based generation while substation assets are rated in Volt-Amperes to account for both the apparent and reactive components of capacity of the equipment. A breakdown of the components for the Tracy 14M Group SHARE fee is shown below:
  3. Page 14 of 27

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set ALLCO-01 Date Issued August 20, 2026 ALLCO-011 Page 2 of 3 Project Type Invisible Distribution Station Distribution Line Total: Enabled Capacity: SHARE Fee: Distribution Customer Reliability Benefit $85 Distribution Customer Capacity Benefit $136 $61.0M $44M $35M $140M $24.5M $7M $9M $40M DER Customer Benefit Total Upgrade Cost $85.5M $180M 218 MVA $392 /KW The SHARE fee represented in this table is produced with the following formula: $392/𝑘𝑘𝑘𝑘 = $85.5M 𝑥𝑥1000 218MVA A breakdown of the components for the Frybrook 13B Group is shown below: Project Type Invisible Distribution Station Distribution Line Total: Enabled Capacity: SHARE Fee: Distribution Customer Reliability Benefit $85 Distribution Customer Capacity Benefit $136 $9.1M $11M $0M $20M $7.2M $2M $1M $10M DER Customer Benefit $16.3M 53 MVA $308 /KW Upgrade Cost $30M
  4. Page 15 of 27

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set ALLCO-01 Date Issued August 20, 2026 ALLCO-011 Page 3 of 3 The SHARE fee represented in this table is produced with the following formula: $16.3M $308/𝑘𝑘𝑘𝑘 = 𝑥𝑥1000 53MVA A breakdown of the components for the Campville 14R Group is shown below: Project Type Invisible Distribution Station Distribution Line Total: Enabled Capacity: SHARE Fee: Distribution Customer Reliability Benefit $36 Distribution Customer Capacity Benefit $59 $28.0M $21M $5M $54M $8.1M $2M $1M $11M DER Customer Benefit $36.1M Upgrade Cost $65M 188 MVA $192 /KW The SHARE fee represented in this table is produced with the following formula: $36.1M $192/𝑘𝑘𝑘𝑘 = 𝑥𝑥1000 188MVA
  5. Page 16 of 27

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set ALLCO-01 Date Issued August 20, 2026 ALLCO-012 Page 1 of 2 Date Filed: September 04, 2026 Witness: Brendan J. O’Brien and Garrett J. Murray Request from: ALLCO Question: Explain how SHARE program investments and SHARE fee revenues would be treated in rate base, depreciation expense, and the revenue requirement, in this docket and prospectively; state whether any SHARE-related capital expenditures are included in the capital additions or five-year investment plan for which recovery is sought in this docket; and identify them. Response: In Docket No. 22-06-29RE01, the Company introduced the Shared Hosting for Advancement of Renewable Energy (“SHARE”) program as a means to cost effectively enable Distributed Energy Resource (“DER”) interconnection and to ensure that interconnection upgrade costs are equitably allocated among DER customers and non-DER customers. In that proceeding, the EDCs (CL&P and The United Illuminating Company) collectively submitted comments in response to PURA’s Notice of Request for Written Comments issued on December 22, 2023. In those comments, the EDCs comments indicated that the following framework would need to be established in order to effectuate the SHARE program: The EDC will recover the costs of the Interconnection Solution through two channels. First, interconnecting customers in the Group will offset the upfront construction or implementation costs through a $/kW Interconnection Solution fee based on the interconnecting facility’s prorata share of the cost of the Interconnection Solution. Interconnecting customers in the Group shall pay a portion of the total Interconnection Solution cost based on technical analysis. This fee will be treated as a contribution in aid of construction (“CIAC”) and will be grossed up for taxes to ensure the full CIAC, plus gross-up, will hold distribution customers harmless on the deferred income tax implication to rate base in each Company’s next rate case. Second, the EDC will recover the remaining Interconnection Solution incurred costs with subsequent recovery from distribution customers through a rate reconciliation mechanism the Authority reviews and approves in the RAM proceeding. Distributed energy resource (DER) facilities that connect to the distribution system at a future time using the newly enabled hosting capacity will pay all of the associated Interconnection Solution fee, which will be flowed through the same rate reconciliation mechanism and credited back to
  6. Page 17 of 27

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set ALLCO-01 Date Issued August 20, 2026 ALLCO-012 Page 2 of 2 distribution customers. Docket 22-06-29RE01, February 14, 2024 EDC comments in response to PURA request for written comments on December 22, 2023. In this proceeding, the Company presented Exhibit CLP-TSP-3 in which it provided three investment scenarios; 1) Sustained Performance, 2) Targeted System Performance, and 3) Advancing the Grid. In this proceeding, the Company has proposed to implement in base rates the capital expenditures associated with the Targeted System Performance scenario presented in Exhibit CLP-TSP-3, which does not include SHARE investments. However, the five-year investment Advancing the Grid plan includes specific investments to upgrade 3 bulk substations, build 2 new bulk substations and add new distribution feeder capacity in three (3) areas of the system to improve hosting capacity for DER integration. The high-level planning estimate for these major upgrades is approximately $275M, which would be allocated equally between DER customers and distribution customers based on a preliminary technical review of benefits (Exhibit CLP-TSP-3 at 146 to 149). Based on anticipated study, engineering, and construction schedules, $47.6M of capital expenditure is included in the five-year investment plan under the Advancing the Grid Investment Scenario (Exhibit CLP-TSP-3 at 9). Should PURA opt to support the Advancing the Grid plan as part of this proceeding, or, in a future proceeding, implement the SHARE program and associated cost recovery as proposed by the EDCs in Docket No. 22-06-29RE01, the gross investments would be reflected in plant in service installed by the Company. As described above, Interconnection Solution fees would be collected as a CIAC which would offset plant in service in rate bae. Depreciation expense would be calculated on the gross plant additions, less the CIAC. The revenue requirement that customers would pay through a rate reconciliation mechanism would be calculated on the gross plant investment, less the CIAC.
  7. Page 18 of 27

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set ALLCO-01 Date Issued August 20, 2026 ALLCO-013 Page 1 of 2 Date Filed: September 14, 2026 Witness: Lavelle A. Freeman, Juan F. Martinez, and Steven C. Osuch Request from: ALLCO Question: With respect to the contemplated "Bul Substation near Hampton" (Exhibit CLP-TSP-3 at 146): state its proposed scope, cost estimate, and in-service timing; identify the in-queue projects it is intended to enable, including their application dates and queue positions; and state how projects with pending applications at the Card Street 11F substation or on Circuit 11F14 — including applications pending since 2017 and 2018 — would be treated under the SHARE proposal, including whether and how amounts previously paid by such earlier-queued customers (deposits, study fees, CIAC, and upgrade payments) would be credited against any SHARE fee. Response: CL&P objects to this request on the ground that it is an improper effort by Allco to use this rate case proceeding to obtain discovery for purposes of a lawsuit that it filed against the Company on August 10, 2026, in the United States District Court for the District of Connecticut (Civil Action No. 3:26-cv-1277), outside of and in contravention of the rules of procedure that govern discovery in that lawsuit. Without waiving said objection, as outlined in Exhibit CLP-TSP-3 at 146, the proposed new bulk substation would be needed to support Tracy 14M, Brooklyn 30Y, and Mansfield 12J. This project is intended to safely and reliably accommodate large-scale DER growth in the area served by the three existing substations, improve system reliability, and resolve capacity constraints due to recent commercial load growth in the region. The preliminary scope of the project includes construction of a new bulk substation with two standard size transformers supplied by transmission sources, and new distribution feeders to pick up loads from the other aforementioned substations in the group, accommodate new loads, connect in-queue DER and enable future DER connections. The project is still in the very early planning stage and no system studies, engineering design or detailed cost estimates have been performed to determine detailed scope, equipment needs, site requirements, resource availability, procurement and construction schedules and myriad other issues that can affect cost and schedule. Therefore, it is not possible, at this preliminary stage, to provide more granularity on scope, cost estimate, and in-service timing than included in Exhibit CLP-TSP-3. If the project were to be constructed today, the in-queue projects it would be intended to enable, including application dates and queue position are available for each of the three substations in the
  8. Page 19 of 27

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set ALLCO-01 Date Issued August 20, 2026 ALLCO-013 Page 2 of 2 published CT DER Queue located on the Company’s Connecticut Application to Connect website. 1 As there are no projects in-queue at the Card Street 11F substation impacted by the preliminary design of this project, it is not possible to say specifically how they would be treated under this SHARE proposal. However, in general, the $/kW SHARE fee would not apply to Level 1 projects. All other projects interconnecting to the group of stations (existing and new) will be required to pay the $/kW SHARE fee which is intended to recover the portion of the cost of common distribution upgrades allocated to DER customers from current (in-queue) and future DER benefiting from those upgrades. This fee does not replace any additional fees associated with interconnection including, but not limited to, application fees, study fees, point-of-interconnection costs or individual or project upgrade requirements identified by a system impact study, such as the installation of a DER Gateway and other project-specific upgrades. If the SHARE Program is approved, the Company will work with stakeholders to develop a Group Study Agreement that outlines how projects with pending applications would be treated including whether and how amounts previously paid by such earlier-queued customers (deposits, study fees, CIAC, and upgrade payments) would be handled. https://www.eversource.com/residential/about/doing-business-with-us/interconnections/connecticut/connecticutapplication-to-connect 1
  9. Page 20 of 27

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set ALLCO-01 Date Issued August 20, 2026 ALLCO-014 Page 1 of 1 Date Filed: September 04, 2026 Witness: Lavelle A. Freeman, Juan F. Martinez, and Steven C. Osuch Request from: ALLCO Question: State whether participation in the SHARE program would be a condition of interconnection for new or pending applications in SHARE target areas, and describe the interconnection path and cost responsibility for a queued project in a SHARE target area that declines to pay the SHARE fee. Response: If the SHARE Program is approved, the Company will work with stakeholders to develop a Group Study Agreement. Based on experience in another jurisdiction, new or pending applications in SHARE target areas would have the option to participate in the SHARE Group Study that determines the Group Solution and associated SHARE fee. If a project elects not to participate in the Group Study, the opt-out project will be queued for study after the Group Study is complete. If there is excess enabled capacity (due to use of standard size equipment) remaining after the Group Study projects have received interconnection agreements (IA), any remaining projects in queue would be eligible to connect and pay the SHARE fee (after their subsequent study). A queued project in a SHARE target area that declines to pay the SHARE fee would be removed from the queue, consistent how a project that declines to pay for the system upgrades identified in a study and outlined in an IA is treated under the current interconnection process.
  10. Page 21 of 27

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set ALLCO-01 Date Issued August 20, 2026 ALLCO-015 Page 1 of 1 Date Filed: September 14, 2026 Witness: Andrew C. Belden Request from: ALLCO Question: In addition to the milestone-component information requested in OCC-137, produce the "recent historical performance" data on which the Company based the proposed 35-business-day target for the Level 1 DER Interconnection Processing component of the Customer PIM Suite (Exhibit CLP-CUSTOMER-1 at 35), including, for each year 2020 through 2025, the annual average number of business days from (a) receipt of a complete DER interconnection application to conditional approval, and (b) municipal inspection to issuance of Permission to Operate, reported separately for residential and non-residential projects. Response: Please refer to ALLCO-015, Attachment 1, for the recent historical performance data on which the Company based the proposed 35-business-day target for the Level 1 DER Interconnection Processing component of the Customer PIM Suite. Only residential projects qualify to apply as Level 1 thus, ALLCO-015, Attachment 1, does not include separately reported non-residential data. Although ALLCO-015, Attachment 1, includes the requested range of 2020-2025, note the metric development only considered the years 2022 through 2025, as the implementation of the Residential Renewable Energy Solutions (RRES) program in 2022 necessitated changes to the interconnection application process to include RRES qualification review. Data prior to 2022 is not representative of the current process. The historical data also may contain time in the applicant queue due to tracking capabilities available in those years.

Text of ALLCO Set 6_COMBINED.pdf

Extracted from the file · 9 pages · 18,340 characters

Text of AMTRAK Set 2_COMBINED.pdf

Extracted from the file · 2 pages · 3,025 characters

Text of AMTRAK Set 1_COMBINED.pdf

Extracted from the file · 5 pages · 4,881 characters

Text of AMTRAK Set 3_COMBINED.pdf

Extracted from the file · 34 pages · 101,991 characters

Text of CIEC Set 2_COMBINED.pdf

Extracted from the file · 1 page · 1,005 characters

Text of CIEC Set 1_COMBINED.pdf

Extracted from the file · 19 pages · 26,023 characters

Text of CIEC Set 3_COMBINED.pdf

Extracted from the file · 4 pages · 5,355 characters

Text of CLF-SC Set 1_COMBINED.pdf

Extracted from the file · 56 pages · 132,578 characters

Text of CLF Set 1_ COMBINED.pdf

Extracted from the file · 20 pages · 38,243 characters

Text of CLF-SC Set 2_COMBINED.pdf

Extracted from the file · 7 pages · 17,131 characters

Text of EOE Set 3_COMBINED.pdf

Extracted from the file · 11 pages · 23,418 characters

Text of EOE Set 2_COMBINED.pdf

Extracted from the file · 22 pages · 42,455 characters

Text of EOE Set 1_COMBINED.pdf

Extracted from the file · 200 pages · 332,382 characters

Text of EOE Set 4_COMBINED.pdf

Extracted from the file · 70 pages · 139,575 characters

Text of ICC Set 1_COMBINED.pdf

Extracted from the file · 30 pages · 51,093 characters

Text of OCC Set 13_COMBINED.pdf

Extracted from the file · 30 pages · 61,971 characters

Text of OCC Set 12_COMBINED.pdf

Extracted from the file · 73 pages · 193,636 characters

Text of OCC Set 11_COMBINED.pdf

Extracted from the file · 48 pages · 62,469 characters

Text of OCC Set 10_COMBINED.pdf

Extracted from the file · 51 pages · 90,368 characters

Text of OCC Set 5_COMBINED.pdf

Extracted from the file · 46 pages · 88,105 characters

Text of OCC Set 4_COMBINED.pdf

Extracted from the file · 159 pages · 268,038 characters

Text of OCC Set 3_COMBINED.pdf

Extracted from the file · 93 pages · 113,517 characters

Text of OCC Set 2_COMBINED.pdf

Extracted from the file · 68 pages · 113,929 characters

Text of OCC Set 1_COMBINED.pdf

Extracted from the file · 139 pages · 225,320 characters

Text of OCC Set 14_COMBINED.pdf

Extracted from the file · 66 pages · 143,197 characters

As listed on the current system

Corres. 09/29/2026 [26-05-10] (Keegan Werlin LLP) - Compilations of discovery responses

This filing on the current system (opens in a new tab)