Compilations of discovery responses
Files31
Docket No. 26-05-10 Discovery Compilations September 29 2026.pdf
PDF · 161 KB · 2 pagesText searchable
Download Docket No. 26-05-10 Discovery Compilations September 29 2026.pdfRead the text of Docket No. 26-05-10 Discovery Compilations September 29 2026.pdf
ALLCO Set 5_COMBINED.pdf
PDF · 669 KB · 36 pagesText searchable
Download ALLCO Set 5_COMBINED.pdfRead the text of ALLCO Set 5_COMBINED.pdf
ALLCO Set 4_COMBINED.pdf
PDF · 133 KB · 4 pagesText searchable
Download ALLCO Set 4_COMBINED.pdfRead the text of ALLCO Set 4_COMBINED.pdf
ALLCO Set 3_COMBINED.pdf
PDF · 346 KB · 23 pagesText searchable
Download ALLCO Set 3_COMBINED.pdfRead the text of ALLCO Set 3_COMBINED.pdf
ALLCO Set 2_COMBINED.pdf
PDF · 576 KB · 38 pagesText searchable
Download ALLCO Set 2_COMBINED.pdfRead the text of ALLCO Set 2_COMBINED.pdf
ALLCO Set 1_COMBINED.pdf
PDF · 458 KB · 27 pagesText searchable
Download ALLCO Set 1_COMBINED.pdfRead the text of ALLCO Set 1_COMBINED.pdf
ALLCO Set 6_COMBINED.pdf
PDF · 332 KB · 9 pagesText searchable
Download ALLCO Set 6_COMBINED.pdfRead the text of ALLCO Set 6_COMBINED.pdf
AMTRAK Set 2_COMBINED.pdf
PDF · 123 KB · 2 pagesText searchable
Download AMTRAK Set 2_COMBINED.pdfRead the text of AMTRAK Set 2_COMBINED.pdf
AMTRAK Set 1_COMBINED.pdf
PDF · 190 KB · 5 pagesText searchable
Download AMTRAK Set 1_COMBINED.pdfRead the text of AMTRAK Set 1_COMBINED.pdf
AMTRAK Set 3_COMBINED.pdf
PDF · 649 KB · 34 pagesText searchable
Download AMTRAK Set 3_COMBINED.pdfRead the text of AMTRAK Set 3_COMBINED.pdf
CIEC Set 2_COMBINED.pdf
PDF · 85 KB · 1 pageText searchable
Download CIEC Set 2_COMBINED.pdfRead the text of CIEC Set 2_COMBINED.pdf
CIEC Set 1_COMBINED.pdf
PDF · 351 KB · 19 pagesText searchable
Download CIEC Set 1_COMBINED.pdfRead the text of CIEC Set 1_COMBINED.pdf
CIEC Set 3_COMBINED.pdf
PDF · 188 KB · 4 pagesText searchable
Download CIEC Set 3_COMBINED.pdfRead the text of CIEC Set 3_COMBINED.pdf
CLF-SC Set 1_COMBINED.pdf
PDF · 611 KB · 56 pagesText searchable
Download CLF-SC Set 1_COMBINED.pdfRead the text of CLF-SC Set 1_COMBINED.pdf
CLF Set 1_ COMBINED.pdf
PDF · 289 KB · 20 pagesText searchable
Download CLF Set 1_ COMBINED.pdfRead the text of CLF Set 1_ COMBINED.pdf
CLF-SC Set 2_COMBINED.pdf
PDF · 182 KB · 7 pagesText searchable
Download CLF-SC Set 2_COMBINED.pdfRead the text of CLF-SC Set 2_COMBINED.pdf
EOE Set 3_COMBINED.pdf
PDF · 237 KB · 11 pagesText searchable
Download EOE Set 3_COMBINED.pdfRead the text of EOE Set 3_COMBINED.pdf
EOE Set 2_COMBINED.pdf
PDF · 417 KB · 22 pagesText searchable
Download EOE Set 2_COMBINED.pdfRead the text of EOE Set 2_COMBINED.pdf
EOE Set 1_COMBINED.pdf
PDF · 1.7 MB · 200 pagesText searchable
Download EOE Set 1_COMBINED.pdfRead the text of EOE Set 1_COMBINED.pdf
EOE Set 4_COMBINED.pdf
PDF · 836 KB · 70 pagesText searchable
Download EOE Set 4_COMBINED.pdfRead the text of EOE Set 4_COMBINED.pdf
ICC Set 1_COMBINED.pdf
PDF · 466 KB · 30 pagesText searchable
Download ICC Set 1_COMBINED.pdfRead the text of ICC Set 1_COMBINED.pdf
OCC Set 13_COMBINED.pdf
PDF · 484 KB · 30 pagesText searchable
Download OCC Set 13_COMBINED.pdfRead the text of OCC Set 13_COMBINED.pdf
OCC Set 12_COMBINED.pdf
PDF · 1.0 MB · 73 pagesText searchable
Download OCC Set 12_COMBINED.pdfRead the text of OCC Set 12_COMBINED.pdf
OCC Set 11_COMBINED.pdf
PDF · 482 KB · 48 pagesText searchable
Download OCC Set 11_COMBINED.pdfRead the text of OCC Set 11_COMBINED.pdf
OCC Set 10_COMBINED.pdf
PDF · 542 KB · 51 pagesText searchable
Download OCC Set 10_COMBINED.pdfRead the text of OCC Set 10_COMBINED.pdf
OCC Set 5_COMBINED.pdf
PDF · 511 KB · 46 pagesText searchable
Download OCC Set 5_COMBINED.pdfRead the text of OCC Set 5_COMBINED.pdf
OCC Set 4_COMBINED.pdf
PDF · 1.3 MB · 159 pagesText searchable
Download OCC Set 4_COMBINED.pdfRead the text of OCC Set 4_COMBINED.pdf
OCC Set 3_COMBINED.pdf
PDF · 1.2 MB · 93 pagesText searchable
Download OCC Set 3_COMBINED.pdfRead the text of OCC Set 3_COMBINED.pdf
OCC Set 2_COMBINED.pdf
PDF · 1.7 MB · 68 pagesText searchable
Download OCC Set 2_COMBINED.pdfRead the text of OCC Set 2_COMBINED.pdf
OCC Set 1_COMBINED.pdf
PDF · 7.0 MB · 139 pagesText searchable
Download OCC Set 1_COMBINED.pdfRead the text of OCC Set 1_COMBINED.pdf
OCC Set 14_COMBINED.pdf
PDF · 880 KB · 66 pagesText searchable
Download OCC Set 14_COMBINED.pdfRead the text of OCC Set 14_COMBINED.pdf
Text of ALLCO Set 3_COMBINED.pdf
Extracted from the file · 23 pages · 55,777 characters
Text of ALLCO Set 2_COMBINED.pdf
Extracted from the file · 38 pages · 81,182 characters
Page 8 of 27
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set ALLCO-01 Date Issued August 20, 2026 ALLCO-006 Page 1 of 1 Date Filed: September 21, 2026 Witness: Brendan J. O’Brien, Garrett J. Murray, Warren R. Boutin, Leanne M. Landry and Jeffrey D. Turano Request from: ALLCO Question: Separately from the customer deposits and customer advances addressed in OCC-74, OCC-75, and OCC-270, state the total amount of deposits, performance assurance, development period security, operating period security, and bid deposits held by the Company from renewable energy developers, qualifying facilities, and interconnection customers as of the end of the Test Year; identify where such amounts are recorded on the Company’s books; state whether such amounts are treated as cost-free capital, an offset to rate base, or otherwise in the proposed revenue requirement; and state the amount of interest accrued and paid on such amounts in the Test Year. Response: CL&P objects to this request on the ground that it is an improper effort by Allco to use this rate case proceeding to obtain discovery for purposes of a lawsuit that it filed against the Company on August 10, 2026, in the United States District Court for the District of Connecticut (Civil Action No. 3:26-cv-1277), outside of and in contravention of the rules of procedure that govern discovery in that lawsuit. Without waiving said objection, the total amount of performance assurance, development period security and operating period security held by the Company was $14,115,950 as of the end of 2025. These deposits are refundable to project owners upon completion of project milestones or, if forfeited, credited as an offset to program costs recovered through fully reconciling rates approved in the Company’s annual Rate Adjustment Mechanism. As such, the funds are not available to the Company for other purposes and are not reflected in the proposed revenue requirement. Lastly, interest only accrues on a deposit when required under the terms of the agreement and is returned or forfeited with original deposit as described above.Page 9 of 27
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set ALLCO-01 Date Issued August 20, 2026 ALLCO-007 Page 1 of 1 Date Filed: September 14, 2026 Witness: Warren R. Boutin Request from: ALLCO Question: State the number of pending distribution interconnection applications in Connecticut that have been pending for more than one year, more than three years, and more than five years, respectively, as of the most recent date available, and for each application pending more than five years, identify the application number, application date, requested capacity (MW), substation and circuit, and current status. Response: CL&P objects to this request on the ground that it is an improper effort by Allco to use this rate case proceeding to obtain discovery for purposes of a lawsuit that it filed against the Company on August 10, 2026, in the United States District Court for the District of Connecticut (Civil Action No. 3:26-cv-1277), outside of and in contravention of the rules of procedure that govern discovery in that lawsuit. Without waiving said objection, the Company maintains and publishes an active interconnection queue for generators greater than 25 kW. The published queue identifies, among other information, the applicable substation, circuit, queue date, and project capacity. The Company also publishes hosting capacity maps that provide location-specific information, including hosting capacity values and DER currently online or in the queue. The information requested regarding individual projects and the applicable substations and circuits is available through the Company’s publicly available interconnection resources. 1 https://www.eversource.com/residential/about/doing-business-with-us/interconnections/connecticut/connecticutapplication-to-connect. 1Page 10 of 27
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set ALLCO-01 Date Issued August 20, 2026 ALLCO-008 Page 1 of 1 Date Filed: September 14, 2026 Witness: Lavelle A. Freeman, Juan F. Martinez, and Steven C. Osuch Request from: ALLCO Question: Produce the data and workpapers supporting the statements in Exhibit CLP-TSP-2 at 43 that "about 260 MW is unable to interconnect without major substation upgrades" at eight identified substations and that "over 550 MW of large solar projects are similarly stuck in interconnection queues across all Eversource substations," including a project-level list showing application date, queue position, MW, substation, and circuit for each project comprising those figures. Response: The Company’s analysis indicates that the available DER hosting capacity is constrained at each of the eight identified substations due to applicable substation equipment thermal loading limitations under the applicable system conditions. As a result, additional DER generation at these locations may require substation upgrades to safely and reliably accommodate interconnection. The applicable DER hosting capacity information is provided in ALLCO-008, Attachment 1. The Company maintains and publishes an active interconnection queue for generators greater than 25 kW. The published queue identifies, among other information, the applicable substation, circuit, queue date, and project capacity. The Company also publishes hosting capacity maps that provide location-specific information, including hosting capacity values and DER currently online or in the queue. The information requested regarding individual projects and the applicable substations and circuits is available through the Company’s publicly available interconnection resources. 1 https://www.eversource.com/residential/about/doing-business-with-us/interconnections/connecticut/connecticutapplication-to-connect. 1Page 11 of 27
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set ALLCO-01 Date Issued August 20, 2026 ALLCO-009 Page 1 of 1 Date Filed: September 21, 2026 Witness: Lavelle A. Freeman, Juan F. Martinez, Steven C. Osuch and Warren R. Boutin Request from: ALLCO Question: For the Card Street 11F substation and each circuit it serves (including Circuit 11F14), identify every interconnection application received since January 1, 2015, showing application number, application date, MW, current status, and (for interconnected projects) the date of interconnection approval and energization; and produce all hosting capacity analyses performed for that substation and its circuits since 2015. Response: CL&P objects to this request on the ground that it is an improper effort by Allco to use this rate case proceeding to obtain discovery for purposes of a lawsuit that it filed against the Company on August 10, 2026, in the United States District Court for the District of Connecticut (Civil Action No. 3:26-cv-1277), outside of and in contravention of the rules of procedure that govern discovery in that lawsuit. Without waiving said objection, the Company maintains and publishes an active interconnection queue for generators greater than 25 kW. The published queue identifies, among other information, the applicable substation, circuit, queue date, and project capacity. The Company also publishes hosting capacity maps that provide location-specific information, including hosting capacity values and DER currently online or in the queue. The information requested regarding individual projects and the applicable substations and circuits is available through the Company’s publicly available interconnection resources. 1 https://www.eversource.com/residential/about/doing-business-with-us/interconnections/connecticut/connecticutapplication-to-connect. 1Page 12 of 27
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set ALLCO-01 Date Issued August 20, 2026 ALLCO-010 Page 1 of 1 Date Filed: September 04, 2026 Witness: Brendan J. O’Brien and Garrett J. Murray Request from: ALLCO Question: State the Test Year and projected Rate Year costs of administering the Company’s Connecticut distributed generation interconnection program (including employee and contractor headcount and costs, and any allocations from Eversource Energy Service Company or from Burns & McDonnell or other third-party project management vendors), and identify where those costs appear in the proposed revenue requirement. Response: Please refer to the table below which shows the Test Year and projected Rate Year O&M expenses associated with administering the Company’s Connecticut distributed generation interconnection program including employee and contractor costs and where they appear in the Company’s cost of service. Description Labor Outside Services/Other Admin Costs Total Schedule C-3.5 Payroll C-3.16 Field Ops – OH Lines Test Year $616,047 $640,960 Rate Year $660,100 $682,263 $1,257,007 $1,342,362Page 13 of 27
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set ALLCO-01 Date Issued August 20, 2026 ALLCO-011 Page 1 of 3 Date Filed: September 04, 2026 Witness: Lavelle A. Freeman, Juan F. Martinez, and Steven C. Osuch Request from: ALLCO Question: Produce the "preliminary analysis" referenced in Exhibit CLP-TSP-3 at 144 supporting the proposed "Avg. Interconnection Fee: < $500/kW," and the workpapers supporting the prospective SHARE fees of $392/kW (Tracy 14M group), $308/kW (Frybrook 13B group), and $192/kW (Campville 14R group) and the associated total distribution investment estimates of $180 million, $30 million, and $65 million (Exhibit CLP-TSP-3 at 146-149). Response: The high-level planning estimates were produced utilizing historical project and unit costs for the preliminary anticipated scopes of these projects. As the SHARE program is a proposed concept, at this time, specific impact studies have not been completed, no level engineering has been performed, and therefore estimates are not available with any more detail than provided in this response. Following PURA’s approval of the SHARE program and the proposed projects, engineering studies would be conducted to develop more detailed scopes and estimates, and project benefits, costs, viability and constructability would evaluated during our internal capital project review and approval process. The SHARE fee represented in the testimony was produced with the following formula: 𝑆𝑆𝑆𝑆𝑆𝑆𝑆𝑆𝑆𝑆 𝐹𝐹𝐹𝐹𝐹𝐹 𝑖𝑖𝑖𝑖 $/𝑘𝑘𝑘𝑘 = Total DER Customer Benefit Upgrade Cost in $M 𝑥𝑥1000 Estimated Enabled Commercial DER Capacity in MVA where 1000 represents the combined unit conversion of Millions of Dollars to Dollars and MVA to kW: $1,000,000 $1000/𝑘𝑘𝑘𝑘 = 1000 kW In these calculations, kW and MW are used synonymously with kVA and MVA given the typical unity power factor of inverter-based generation while substation assets are rated in Volt-Amperes to account for both the apparent and reactive components of capacity of the equipment. A breakdown of the components for the Tracy 14M Group SHARE fee is shown below:Page 14 of 27
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set ALLCO-01 Date Issued August 20, 2026 ALLCO-011 Page 2 of 3 Project Type Invisible Distribution Station Distribution Line Total: Enabled Capacity: SHARE Fee: Distribution Customer Reliability Benefit $85 Distribution Customer Capacity Benefit $136 $61.0M $44M $35M $140M $24.5M $7M $9M $40M DER Customer Benefit Total Upgrade Cost $85.5M $180M 218 MVA $392 /KW The SHARE fee represented in this table is produced with the following formula: $392/𝑘𝑘𝑘𝑘 = $85.5M 𝑥𝑥1000 218MVA A breakdown of the components for the Frybrook 13B Group is shown below: Project Type Invisible Distribution Station Distribution Line Total: Enabled Capacity: SHARE Fee: Distribution Customer Reliability Benefit $85 Distribution Customer Capacity Benefit $136 $9.1M $11M $0M $20M $7.2M $2M $1M $10M DER Customer Benefit $16.3M 53 MVA $308 /KW Upgrade Cost $30MPage 15 of 27
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set ALLCO-01 Date Issued August 20, 2026 ALLCO-011 Page 3 of 3 The SHARE fee represented in this table is produced with the following formula: $16.3M $308/𝑘𝑘𝑘𝑘 = 𝑥𝑥1000 53MVA A breakdown of the components for the Campville 14R Group is shown below: Project Type Invisible Distribution Station Distribution Line Total: Enabled Capacity: SHARE Fee: Distribution Customer Reliability Benefit $36 Distribution Customer Capacity Benefit $59 $28.0M $21M $5M $54M $8.1M $2M $1M $11M DER Customer Benefit $36.1M Upgrade Cost $65M 188 MVA $192 /KW The SHARE fee represented in this table is produced with the following formula: $36.1M $192/𝑘𝑘𝑘𝑘 = 𝑥𝑥1000 188MVAPage 16 of 27
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set ALLCO-01 Date Issued August 20, 2026 ALLCO-012 Page 1 of 2 Date Filed: September 04, 2026 Witness: Brendan J. O’Brien and Garrett J. Murray Request from: ALLCO Question: Explain how SHARE program investments and SHARE fee revenues would be treated in rate base, depreciation expense, and the revenue requirement, in this docket and prospectively; state whether any SHARE-related capital expenditures are included in the capital additions or five-year investment plan for which recovery is sought in this docket; and identify them. Response: In Docket No. 22-06-29RE01, the Company introduced the Shared Hosting for Advancement of Renewable Energy (“SHARE”) program as a means to cost effectively enable Distributed Energy Resource (“DER”) interconnection and to ensure that interconnection upgrade costs are equitably allocated among DER customers and non-DER customers. In that proceeding, the EDCs (CL&P and The United Illuminating Company) collectively submitted comments in response to PURA’s Notice of Request for Written Comments issued on December 22, 2023. In those comments, the EDCs comments indicated that the following framework would need to be established in order to effectuate the SHARE program: The EDC will recover the costs of the Interconnection Solution through two channels. First, interconnecting customers in the Group will offset the upfront construction or implementation costs through a $/kW Interconnection Solution fee based on the interconnecting facility’s prorata share of the cost of the Interconnection Solution. Interconnecting customers in the Group shall pay a portion of the total Interconnection Solution cost based on technical analysis. This fee will be treated as a contribution in aid of construction (“CIAC”) and will be grossed up for taxes to ensure the full CIAC, plus gross-up, will hold distribution customers harmless on the deferred income tax implication to rate base in each Company’s next rate case. Second, the EDC will recover the remaining Interconnection Solution incurred costs with subsequent recovery from distribution customers through a rate reconciliation mechanism the Authority reviews and approves in the RAM proceeding. Distributed energy resource (DER) facilities that connect to the distribution system at a future time using the newly enabled hosting capacity will pay all of the associated Interconnection Solution fee, which will be flowed through the same rate reconciliation mechanism and credited back toPage 17 of 27
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set ALLCO-01 Date Issued August 20, 2026 ALLCO-012 Page 2 of 2 distribution customers. Docket 22-06-29RE01, February 14, 2024 EDC comments in response to PURA request for written comments on December 22, 2023. In this proceeding, the Company presented Exhibit CLP-TSP-3 in which it provided three investment scenarios; 1) Sustained Performance, 2) Targeted System Performance, and 3) Advancing the Grid. In this proceeding, the Company has proposed to implement in base rates the capital expenditures associated with the Targeted System Performance scenario presented in Exhibit CLP-TSP-3, which does not include SHARE investments. However, the five-year investment Advancing the Grid plan includes specific investments to upgrade 3 bulk substations, build 2 new bulk substations and add new distribution feeder capacity in three (3) areas of the system to improve hosting capacity for DER integration. The high-level planning estimate for these major upgrades is approximately $275M, which would be allocated equally between DER customers and distribution customers based on a preliminary technical review of benefits (Exhibit CLP-TSP-3 at 146 to 149). Based on anticipated study, engineering, and construction schedules, $47.6M of capital expenditure is included in the five-year investment plan under the Advancing the Grid Investment Scenario (Exhibit CLP-TSP-3 at 9). Should PURA opt to support the Advancing the Grid plan as part of this proceeding, or, in a future proceeding, implement the SHARE program and associated cost recovery as proposed by the EDCs in Docket No. 22-06-29RE01, the gross investments would be reflected in plant in service installed by the Company. As described above, Interconnection Solution fees would be collected as a CIAC which would offset plant in service in rate bae. Depreciation expense would be calculated on the gross plant additions, less the CIAC. The revenue requirement that customers would pay through a rate reconciliation mechanism would be calculated on the gross plant investment, less the CIAC.
Text of ALLCO Set 6_COMBINED.pdf
Extracted from the file · 9 pages · 18,340 characters
Text of AMTRAK Set 2_COMBINED.pdf
Extracted from the file · 2 pages · 3,025 characters
Text of AMTRAK Set 1_COMBINED.pdf
Extracted from the file · 5 pages · 4,881 characters
Text of AMTRAK Set 3_COMBINED.pdf
Extracted from the file · 34 pages · 101,991 characters
Text of CIEC Set 2_COMBINED.pdf
Extracted from the file · 1 page · 1,005 characters
Text of CIEC Set 1_COMBINED.pdf
Extracted from the file · 19 pages · 26,023 characters
Text of CIEC Set 3_COMBINED.pdf
Extracted from the file · 4 pages · 5,355 characters
Text of CLF-SC Set 1_COMBINED.pdf
Extracted from the file · 56 pages · 132,578 characters
Text of CLF Set 1_ COMBINED.pdf
Extracted from the file · 20 pages · 38,243 characters
Text of CLF-SC Set 2_COMBINED.pdf
Extracted from the file · 7 pages · 17,131 characters
Text of EOE Set 3_COMBINED.pdf
Extracted from the file · 11 pages · 23,418 characters
Text of EOE Set 2_COMBINED.pdf
Extracted from the file · 22 pages · 42,455 characters
Text of EOE Set 1_COMBINED.pdf
Extracted from the file · 200 pages · 332,382 characters
Text of EOE Set 4_COMBINED.pdf
Extracted from the file · 70 pages · 139,575 characters
Text of ICC Set 1_COMBINED.pdf
Extracted from the file · 30 pages · 51,093 characters
Text of OCC Set 13_COMBINED.pdf
Extracted from the file · 30 pages · 61,971 characters
Text of OCC Set 12_COMBINED.pdf
Extracted from the file · 73 pages · 193,636 characters
Text of OCC Set 11_COMBINED.pdf
Extracted from the file · 48 pages · 62,469 characters
Text of OCC Set 10_COMBINED.pdf
Extracted from the file · 51 pages · 90,368 characters
Text of OCC Set 5_COMBINED.pdf
Extracted from the file · 46 pages · 88,105 characters
Text of OCC Set 4_COMBINED.pdf
Extracted from the file · 159 pages · 268,038 characters
Text of OCC Set 3_COMBINED.pdf
Extracted from the file · 93 pages · 113,517 characters
Text of OCC Set 2_COMBINED.pdf
Extracted from the file · 68 pages · 113,929 characters
Text of OCC Set 1_COMBINED.pdf
Extracted from the file · 139 pages · 225,320 characters
Text of OCC Set 14_COMBINED.pdf
Extracted from the file · 66 pages · 143,197 characters
As listed on the current system
Corres. 09/29/2026 [26-05-10] (Keegan Werlin LLP) - Compilations of discovery responses