Skip to main content

A prototype public docket site for the Connecticut Public Utilities Regulatory Authority

Utility Dockets and Filings

Compilations of discovery responses

Files31

Search terms highlighted
Eversource rate increase is on 144 pages across 21 files of the text below, highlighted. Go to the first matchClear highlighting
Words on different pages
15 pages match
Words on different pages

Text of ALLCO Set 3_COMBINED.pdf

Extracted from the file · 23 pages · 55,777 characters

Text of ALLCO Set 2_COMBINED.pdf

Extracted from the file · 38 pages · 81,182 characters

Text of ALLCO Set 1_COMBINED.pdf

Extracted from the file · 27 pages · 46,644 characters

Text of ALLCO Set 6_COMBINED.pdf

Extracted from the file · 9 pages · 18,340 characters

Text of AMTRAK Set 2_COMBINED.pdf

Extracted from the file · 2 pages · 3,025 characters

Text of AMTRAK Set 1_COMBINED.pdf

Extracted from the file · 5 pages · 4,881 characters

Text of AMTRAK Set 3_COMBINED.pdf

Extracted from the file · 34 pages · 101,991 characters

Text of CIEC Set 2_COMBINED.pdf

Extracted from the file · 1 page · 1,005 characters

Text of CIEC Set 1_COMBINED.pdf

Extracted from the file · 19 pages · 26,023 characters

Text of CIEC Set 3_COMBINED.pdf

Extracted from the file · 4 pages · 5,355 characters

1 page match
  1. Page 11 of 56

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set CLF-SC-01 Date Issued August 28, 2026 CLF-SC-006 Page 1 of 4 Date Filed: September 18, 2026 Witness: Amparo Nieto Request from: CLF and Sierra Club Question: For the Test Year provided by the Company in this rate case, please provide (a.) the Company's calculation of the cost of service (i.e., cost to serve) for each of the following residential customers groups: residential customers whose primary heating is 1. electric resistance, 2. natural gas, 3. delivered fuels (e.g., fuel oil, propane), and 4. other/unknown. Please also provide (b.) a detailed description of the methodology used to develop these cost of service figures, as well as all (c.) data sources, allocators, and assumptions used, in live Microsoft Excel format with all formulae unlocked. If the Company does not possess the information necessary to calculate the cost of service for any of the four customer groups above, please explain in detail why not for each such group. If the Company is unable to produce these figures for the Test Year, but is able to do so for a different time period, please use the same time period used to satisfy CLF-SC-3, and CLF-SC4. Response: The cost of service cannot be calculated for customers differentiated as in the listed groups 2 through 4. Please refer to the Company’s responses to CLF-SC-003 i, CLF-SC-004 ii, and CLFSC-005 iii. Please note, however, in the filed allocated cost of service study, the cost to serve for Rate 5 Residential Space Heating customers has been provided, and the cost to serve for Rate 1 and Rate 7 includes all heating sources, though there is not the ability to differentiate by the groups requested, as the Company does not track such sources or differentiate customer service requirements and characteristics on that basis. Prior Referenced Responses: i CLF-SC-003 Question: For the Test Year in this proceeding, please provide: a. the number of residential electric customers with a heat pump as their primary heating source; b. the total electricity consumption (kWh) of these customers; c. the total electric delivery revenue attributable to these customers, in the aggregate. The Company may provide this information either as a summary table or as the underlying billing and customer data
  2. Page 12 of 56

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set CLF-SC-01 Date Issued August 28, 2026 CLF-SC-006 Page 2 of 4 necessary to derive it (e.g., anonymized billing-quality data identifying each customer's heating source, together with that customer's kWh consumption and delivery revenue for the period). Please provide this information in CSV format or in live Microsoft Excel format (with all formulae intact). If the Company does not possess the information necessary to produce any of the three items requested (heat pump customer count, consumption, or delivery revenue), please state specifically which item(s) the Company is unable to provide, and explain in detail why not for each. If the Company is not able to produce all three items requested for the Test Year, but is able to do so for a different time period, please provide these figures for the most recent time period available. CLF-SC-003 Response: Since the Company does not track the heating sources of its customers, the Company has evaluated data collected from Energy Efficiency rebates issued to customers who (1) installed a qualifying heat pump at their residence and (2) submitted for a rebate. This information does not represent all customers who may have heat pumps. ii a. Evaluation of data from rebate program which began in 2023 indicates there have been approximately 4,400 customers who have received heat pump rebates that indicate full displacement of other heat sources and use heat pumps as their primary heating source b. The Company does not know the total number of residential electric customers utilizing heat pumps as their primary heating source during the Test Year and accordingly is unable to query those customers’ total kWh consumption or determine or estimate total delivery revenue. c. Refer to the Company’s response to subpart (b), above. CLF-SC-004 Question: For the same Test Year specified in the preceding request, please provide the number of residential electric customers, total electricity consumption (kWh), and total electric delivery revenue, broken out separately for the residential customer groups whose primary heating is: a. electric resistance b. natural gas c. delivered fuels (e.g., fuel oil, propane) d. other/unknown heating sources Please provide this information in the same format requested in the preceding request. If the Company does not possess the information necessary to produce any of the three items requested (customer count, consumption, or delivery revenue) for any of the residential customer categories listed above, please state specifically which items and/or categories the Company is unable to provide, and explain in detail why not for each item and category identified. If the Company is not able to produce all three items requested for each category for the Test Year, but is able to do so for a different time period, please provide these figures for the same time period as is used in CLF-SC-3. CLF-SC-004 Response: Since the Company does not track the heating sources of its customers, the following response used best available data collected from multiple sources to approximate the following amounts for this request.
  3. Page 13 of 56

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set CLF-SC-01 Date Issued August 28, 2026 CLF-SC-006 Page 3 of 4 a. For the Test Year 2025, the Company provided electric service to 135,073 customers on Rate 5 Residential Electric Heating Service. While there may be customers serviced under Rates 1 or 7 who heat with electric resistance, the customer count of Rate 5 provides a definitive measure of those customers with electric space heating. For the Test Year 2025, the total electricity consumption of these customers was approximately 1,594,819,665 kWh For the Test Year 2025, the Company calculated an estimated total delivery revenue, using average Rate 5 delivery rateii for 2025, of approximately $289,698,992. b. The Company estimates that for the Test Year, 2025, there are approximately 31,548 CL&P Residential customers received service under either the Yankee Gas Rate 2 Residential Heating rate or the Yankee Gas Rate 3 Residential Multi-Dwelling rate, and who therefore may be assumed to heat using natural gas. The Company cannot account for any customers who may receive natural gas from any company other than Yankee Gas Company. For the Test Year 2025, the total electricity consumption of these customers was approximately 177,787,876 kWh. For the Test Year 2025, the Company calculated an estimated total delivery revenue, using an average Residential delivery rateii for 2025, of approximately $34,721,972. c. For the Test Year 2025, the Company estimates there are approximately 2,089 CL&P Residential customers who receive service under the Yankee Gas Rate 1 Residential Non-Heating rate that are not on CL&P Rate 5 Residential Electric Heating Service. Therefore, it may be assumed that these customers are heating with delivered fuels (e.g. fuel oil, propane). The Company cannot predict the heating source of any other customers. For the Test Year 2025, the total electricity consumption of these customers was approximately 10,915,087 kWh. For the Test Year 2025, the Company calculated an estimated total delivery revenue, using an average Residential delivery rateii for 2025, of approximately $2,131,716. d. iii This information is not available. CLF-SC-005 Question: For the Test Year provided by the Company in this rate case, please provide (a.) the Company's calculation of the cost of service (i.e., cost to serve) attributable to residential electric customers with a heat pump as their primary heating source, in the aggregate, together with (b.) a detailed description of the methodology used to develop this cost of service figure, as well as (c.) data sources, allocators, and assumptions used, in live Microsoft Excel format with all formulae unlocked. If the Company's cost of service calculations use a different period than the one specified above, please identify the period actually used. If the Company does not possess the information necessary to calculate the cost of service for heat pump customers, please explain in detail why not. If the Company is unable to produce this figure for the Test Year, but is able to do so for a different time period, please use the same time period used to satisfy CLF-SC-3, and CLF-SC-4.
  4. Page 14 of 56

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set CLF-SC-01 Date Issued August 28, 2026 CLF-SC-006 Page 4 of 4 CLF-SC-005 Response: The Company ACOS study does not calculate the cost to serve a residential customer (assuming the total, or whole house requirements) with a heat pump as their primary heating source. Please refer to the Company’s responses to CLF-SC-003,iii and CLF-SC-004iii. The ACOS study only allocates costs to rate classes with existing customers and billing determinants as defined by such rate classes. Conceivably, a new class or subclass of service would need to be defined and all data similar to that relied upon and used in the filed cost of service study (including but not limited to appropriate load data and distribution facility service, utilization and cost characteristics) for rate classes in that study would be required to conduct a similar allocation of costs among all rate classes reflective of such new class or subclass.
  5. Page 15 of 56

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set CLF-SC-01 Date Issued August 28, 2026 CLF-SC-007 Page 1 of 5 Date Filed: September 18, 2026 Witness: Amparo Nieto Request from: CLF and Sierra Club Question: To the extent the Company is unable to provide the specific cost of service data requested in CLFSC-5, and/or CLF-SC-6, above for any heating source category, please provide a detailed technical description of the methodology the Company would use to calculate cost of service by heating source category, if the Company were asked to do so. This description should be in sufficient technical detail that a third party, given access to the underlying source data, could independently replicate the analysis. Please identify: a. what data sources would be needed (e.g., the Company's ECOSS functionalized/classified costs and allocators, customer billing records, AMI interval data, HVAC equipment or permit records, customer surveys, appliance saturation studies, or similar); b. whether the Company possesses that source data, and if not, who would possess the data; c. the specific analytical steps that would be required to convert that source data into a cost of service figure for each heating source category. Response: a. As briefly described in the response to CLF-SC-006 i, all of the data for a given rate class, with the residential rate classes represented in the filed allocated cost of service study (refer to Exhibit CLP-ACOS-1, and associated exhibits and workpapers) providing a basis upon which the data sources for a class so defined by the question would also need to be developed, and such class would be part of the overall allocated cost study. (i.e, a new rate class would need to be developed, and a [re]allocation of costs among all classes would need to be performed). b. Please refer to the responses to CLF-SC-003 ii, CLF-SC-004 iii, CLF-SC-005 iv, and CLF-SC006. c. Please refer to the response to subpart (a), above. The Company would use the same allocation methods as those used for other rate classes, as appropriate for such new class(es). Details of previously described methods and data development needed include meeting requirements and development of load research and customer cost characteristics, calculation of e the new rate class NCP, customer numbers and customer weighting factors, obtaining and analyzing records and assumptions regarding secondary service characteristics, line transformer and
  6. Page 16 of 56

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set CLF-SC-01 Date Issued August 28, 2026 CLF-SC-007 Page 2 of 5 service connections, and, for rate classes affected by differentiation of new classes from which they are derived, a revision and recalculation of all of the similar and relevant cost of service data for those classes would need to be performed. It is critical that any such new class exhibit sufficient, homogenous and differentiated characteristics, and that similarly for the newly differentiated rate class affected by the splitting out of subclass customers to form a new rate class. Of note, further consideration must be given to the impact beyond distribution cost of service to other components of service for which, in particular, class allocations would be affected and revisions to the allocation of costs for those other components of service would need to be revised. Prior Referenced Responses: i CLF-SC-006 Question: For the Test Year provided by the Company in this rate case, please provide (a.) the Company's calculation of the cost of service (i.e., cost to serve) for each of the following residential customers groups: residential customers whose primary heating is 1. electric resistance, 2. natural gas, 3. delivered fuels (e.g., fuel oil, propane), and 4. other/unknown. Please also provide (b.) a detailed description of the methodology used to develop these cost of service figures, as well as all (c.) data sources, allocators, and assumptions used, in live Microsoft Excel format with all formulae unlocked. If the Company does not possess the information necessary to calculate the cost of service for any of the four customer groups above, please explain in detail why not for each such group. If the Company is unable to produce these figures for the Test Year, but is able to do so for a different time period, please use the same time period used to satisfy CLFSC-3, and CLF-SC-4. CLF-SC-006 Response: The cost of service cannot be calculated for customers differentiated as in the listed groups 2 through 4. Please refer to the Company’s responses to CLF-SC-003i, CLF-SC-004i, and CLF-SC-005i. Please note, however, in the filed allocated cost of service study, the cost to serve for Rate 5 Residential Space Heating customers has been provided, and the cost to serve for Rate 1 and Rate 7 includes all heating sources, though there is not the ability to differentiate by the groups requested, as the Company does not track such sources or differentiate customer service requirements and characteristics on that basis. ii CLF-SC-003 Question: For the Test Year in this proceeding, please provide: a.the number of residential electric customers with a heat pump as their primary heating source; b.the total electricity consumption (kWh) of these customers; c.the total electric delivery revenue attributable to these customers, in the aggregate. The Company may provide this information either as a summary table or as the underlying billing and customer data necessary to derive it (e.g., anonymized billing-quality data identifying each customer's heating source, together with that customer's kWh consumption and delivery revenue for the period). Please provide this information in CSV format
  7. Page 17 of 56

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set CLF-SC-01 Date Issued August 28, 2026 CLF-SC-007 Page 3 of 5 or in live Microsoft Excel format (with all formulae intact). If the Company does not possess the information necessary to produce any of the three items requested (heat pump customer count, consumption, or delivery revenue), please state specifically which item(s) the Company is unable to provide, and explain in detail why not for each. If the Company is not able to produce all three items requested for the Test Year, but is able to do so for a different time period, please provide these figures for the most recent time period available. CLF-SC-003 Response: Since the Company does not track the heating sources of its customers, the Company has evaluated data collected from Energy Efficiency rebates issued to customers who (1) installed a qualifying heat pump at their residence and (2) submitted for a rebate. This information does not represent all customers who may have heat pumps. iii a. Evaluation of data from rebate program which began in 2023 indicates there have been approximately 4,400 customers who have received heat pump rebates that indicate full displacement of other heat sources and use heat pumps as their primary heating source b. The Company does not know the total number of residential electric customers utilizing heat pumps as their primary heating source during the Test Year and accordingly is unable to query those customers’ total kWh consumption or query or calculate total delivery revenue. c. Refer to the Company’s response to subpart (b), above. CLF-SC-004 Question: For the same Test Year specified in the preceding request, please provide the number of residential electric customers, total electricity consumption (kWh), and total electric delivery revenue, broken out separately for the residential customer groups whose primary heating is: a.electric resistance b.natural gas c.delivered fuels (e.g., fuel oil, propane) d.other/unknown heating sources Please provide this information in the same format requested in the preceding request. If the Company does not possess the information necessary to produce any of the three items requested (customer count, consumption, or delivery revenue) for any of the residential customer categories listed above, please state specifically which items and/or categories the Company is unable to provide, and explain in detail why not for each item and category identified. If the Company is not able to produce all three items requested for each category for the Test Year, but is able to do so for a different time period, please provide these figures for the same time period as is used in CLF-SC-3. CLF-SC-004 Response: Since the Company does not track the heating sources of its customers, the following response used best available data collected from multiple sources to approximate the following amounts for this request.
  8. Page 18 of 56

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set CLF-SC-01 Date Issued August 28, 2026 CLF-SC-007 Page 4 of 5 a. For the Test Year 2025, the Company provided electric service to 135,073 customers on Rate 5 Residential Electric Heating Service. While there may be customers serviced under Rates 1 or 7 who heat with electric resistance, the customer count of Rate 5 provides a definitive measure of those customers with electric space heating. For the Test Year 2025, the total electricity consumption of these customers was approximately 1,594,819,665 kWh For the Test Year 2025, the Company calculated an estimated total delivery revenue, using average Rate 5 delivery rateiii for 2025, of approximately $289,698,992. b. The Company estimates that for the Test Year, 2025, there are approximately 31,548 CL&P Residential customers received service under either the Yankee Gas Rate 2 Residential Heating rate or the Yankee Gas Rate 3 Residential Multi-Dwelling rate, and who therefore may be assumed to heat using natural gas. The Company cannot account for any customers who may receive natural gas from any company other than Yankee Gas Company. For the Test Year 2025, the total electricity consumption of these customers was approximately 177,787,876 kWh. For the Test Year 2025, the Company calculated an estimated total delivery revenue, using an average Residential delivery rateiii for 2025, of approximately $34,721,972. c. For the Test Year 2025, the Company estimates there are approximately 2,089 CL&P Residential customers who receive service under the Yankee Gas Rate 1 Residential Non-Heating rate that are not on CL&P Rate 5 Residential Electric Heating Service. Therefore, it may be assumed that these customers are heating with delivered fuels (e.g. fuel oil, propane). The Company cannot predict the heating source of any other customers. For the Test Year 2025, the total electricity consumption of these customers was approximately 10,915,087 kWh. For the Test Year 2025, the Company calculated an estimated total delivery revenue, using an average Residential delivery rateiii for 2025, of approximately $2,131,716. d. iv This information is not available. CLF-SC-005 Question: For the Test Year provided by the Company in this rate case, please provide (a.) the Company's calculation of the cost of service (i.e., cost to serve) attributable to residential electric customers with a heat pump as their primary heating source, in the aggregate, together with (b.) a detailed description of the methodology used to develop this cost of service figure, as well as (c.) data sources, allocators, and assumptions used, in live Microsoft Excel format with all formulae unlocked. If the Company's cost of service calculations use a different period than the one specified above, please identify the period actually used. If the Company does not possess the information necessary to calculate the cost of service for heat pump customers, please explain in detail why not. If the Company is unable to produce this figure for the Test Year, but is able to do so for a different time period, please use the same time period used to satisfy CLF-SC-3, and CLF-SC-4.
  9. Page 19 of 56

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set CLF-SC-01 Date Issued August 28, 2026 CLF-SC-007 Page 5 of 5 CLF-SC-005 Response: The Company ACOS study does not calculate the cost to serve a residential customer (assuming the total, or whole house requirements) with a heat pump as their primary heating source. Please refer to the Company’s responses to CLF-SC-003iv, and CLF-SC-004iv. The ACOS study only allocates costs to rate classes with existing customers and billing determinants as defined by such rate classes. Conceivably, a new class or subclass of service would need to be defined and all data similar to that relied upon and used in the filed cost of service study (including but not limited to appropriate load data and distribution facility service, utilization and cost characteristics) for rate classes in that study would be required to conduct a similar allocation of costs among all rate classes reflective of such new class or subclass.
  10. Page 20 of 56

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set CLF-SC-01 Date Issued August 28, 2026 CLF-SC-008 Page 1 of 3 Date Filed: September 18, 2026 Witness: Edward A. Davis and Kimberly R. Parsons Request from: CLF and Sierra Club Question: Please provide the aggregate hourly (or, if hourly is not available, the finest available sub-hourly interval, e.g., 15-minute or 30-minute) electric energy usage (in kWh per interval), summed across all residential electric customers with a heat pump as their primary heating source, for each hour (or interval) of the test year in this proceeding. If interval or AMI data are not available for that exact period, please provide data for the same twelve-month period used to satisfy CLF-SC-3 through CLF-SC-6, and identify the period provided. Monthly or less granular data will not satisfy this request; the resolution requested is hourly or finer. Please provide this information in a machine-readable live Microsoft Excel or CSV format, with one row per timestamp/interval and a labeled timestamp column (not a static image, PDF, or pivoted/merged-cell table), together with a description of how the underlying interval or AMI data were aggregated (e.g., whether the figures reflect gross metered usage or are net of any behind-the-meter generation, and how customers with incomplete interval data, if any, were treated). Please use the same timestamp convention — including time zone, whether intervals are labeled by interval-beginning or interval-ending, and treatment of daylight saving time transitions — in this response and in the responses to CLF-SC9 through 11 below, and identify that convention, so that the results can be directly and unambiguously aligned and summed across heating source categories, rate schedules, and total system load. If the Company does not possess the information necessary to produce this aggregated load profile (including because the Company cannot identify which customers have a heat pump), please explain in detail why not. Response: The Company does not employ AMI meters and does not have the data requested. As has been described and explained in responses to CLF-SC-003 i through CLF-SC-007 ii, the Company does not track or know all residential electric customers with a heat pump as their primary heating source. Moreover, except for the relatively small sample of customers under Rate 1 or Rate 5, and those under Rate 7 where interval data recording meters are employed, the Company does not utilize interval recording meters for the vast majority of residential customers. Rather monthly usage data is recorded and utilized in billing of such customers. Given the very small number of customers with interval meters, an even smaller subset of these customers can be expected to utilize a heat pump as their primary heat source. Class level load research data that provides average hourly loads is developed based on sample data, and therefore does not differentiate fuel source and accordingly does not provide the data requested.

Text of CLF Set 1_ COMBINED.pdf

Extracted from the file · 20 pages · 38,243 characters

Text of CLF-SC Set 2_COMBINED.pdf

Extracted from the file · 7 pages · 17,131 characters

Text of EOE Set 3_COMBINED.pdf

Extracted from the file · 11 pages · 23,418 characters

Text of EOE Set 2_COMBINED.pdf

Extracted from the file · 22 pages · 42,455 characters

Text of EOE Set 1_COMBINED.pdf

Extracted from the file · 200 pages · 332,382 characters

Text of EOE Set 4_COMBINED.pdf

Extracted from the file · 70 pages · 139,575 characters

Text of ICC Set 1_COMBINED.pdf

Extracted from the file · 30 pages · 51,093 characters

Text of OCC Set 13_COMBINED.pdf

Extracted from the file · 30 pages · 61,971 characters

Text of OCC Set 12_COMBINED.pdf

Extracted from the file · 73 pages · 193,636 characters

Text of OCC Set 11_COMBINED.pdf

Extracted from the file · 48 pages · 62,469 characters

Text of OCC Set 10_COMBINED.pdf

Extracted from the file · 51 pages · 90,368 characters

Text of OCC Set 5_COMBINED.pdf

Extracted from the file · 46 pages · 88,105 characters

Text of OCC Set 4_COMBINED.pdf

Extracted from the file · 159 pages · 268,038 characters

Text of OCC Set 3_COMBINED.pdf

Extracted from the file · 93 pages · 113,517 characters

Text of OCC Set 2_COMBINED.pdf

Extracted from the file · 68 pages · 113,929 characters

Text of OCC Set 1_COMBINED.pdf

Extracted from the file · 139 pages · 225,320 characters

Text of OCC Set 14_COMBINED.pdf

Extracted from the file · 66 pages · 143,197 characters

As listed on the current system

Corres. 09/29/2026 [26-05-10] (Keegan Werlin LLP) - Compilations of discovery responses

This filing on the current system (opens in a new tab)