Skip to main content

A prototype public docket site for the Connecticut Public Utilities Regulatory Authority

Utility Dockets and Filings

Compilations of discovery responses

Files31

Search terms highlighted
Eversource rate increase is on 144 pages across 21 files of the text below, highlighted. Go to the first matchClear highlighting
Words on different pages
15 pages match
Words on different pages

Text of ALLCO Set 3_COMBINED.pdf

Extracted from the file · 23 pages · 55,777 characters

Text of ALLCO Set 2_COMBINED.pdf

Extracted from the file · 38 pages · 81,182 characters

Text of ALLCO Set 1_COMBINED.pdf

Extracted from the file · 27 pages · 46,644 characters

Text of ALLCO Set 6_COMBINED.pdf

Extracted from the file · 9 pages · 18,340 characters

Text of AMTRAK Set 2_COMBINED.pdf

Extracted from the file · 2 pages · 3,025 characters

Text of AMTRAK Set 1_COMBINED.pdf

Extracted from the file · 5 pages · 4,881 characters

Text of AMTRAK Set 3_COMBINED.pdf

Extracted from the file · 34 pages · 101,991 characters

Text of CIEC Set 2_COMBINED.pdf

Extracted from the file · 1 page · 1,005 characters

Text of CIEC Set 1_COMBINED.pdf

Extracted from the file · 19 pages · 26,023 characters

Text of CIEC Set 3_COMBINED.pdf

Extracted from the file · 4 pages · 5,355 characters

Text of CLF-SC Set 1_COMBINED.pdf

Extracted from the file · 56 pages · 132,578 characters

Text of CLF Set 1_ COMBINED.pdf

Extracted from the file · 20 pages · 38,243 characters

Text of CLF-SC Set 2_COMBINED.pdf

Extracted from the file · 7 pages · 17,131 characters

Text of EOE Set 3_COMBINED.pdf

Extracted from the file · 11 pages · 23,418 characters

Text of EOE Set 2_COMBINED.pdf

Extracted from the file · 22 pages · 42,455 characters

Text of EOE Set 1_COMBINED.pdf

Extracted from the file · 200 pages · 332,382 characters

Text of EOE Set 4_COMBINED.pdf

Extracted from the file · 70 pages · 139,575 characters

Text of ICC Set 1_COMBINED.pdf

Extracted from the file · 30 pages · 51,093 characters

2 pages match
  1. Page 1 of 30

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set OCC-13 Date Issued September 02, 2026 OCC-544 Page 1 of 2 Date Filed: September 16, 2026 Witness: Donald J. Scacco Jr., Christopher E. Colorio, and Mark P. Baldwin Request from: Office of Consumer Counsel Question: Referring to Exhibit CLP-STORM-1 at 41. The Company states that it “does not apply a specific formula” to correlate forecast damage locations to crew quantity. Please explain the method used to translate expected damage into crew requirements, including the role of professional judgment. Response: The Company does not use a formula to “correlate” forecast damage locations to crew quantity because this implies that the Company has access to a forecast of damage locations that is sufficiently predictive of the actual damage locations that will occur within the context of any given weather system for the Company to rely on the “correlation” outcome, which is not the case. The Company’s experience and expertise is that the damage prediction models are not sufficiently accurate to cause the Company to rely conclusively on those predictions for crew sourcing. For example, an issue for the damage prediction models is that damage occurs on a localized basis, whereas Connecticut has not historically hosted weather stations in a sufficient number of locations to provide localized historical weather data that could be used by damage prediction models to potentially refine the output of the models. Methodologically, the damage prediction models do not yet have a level of reliability and accuracy to form a substantial or primary basis of crew sourcing. As stormy conditions are approaching the Eversource distribution system, the Company’s analytical exercise therefore is to gather, study and evaluate the approaching weather conditions and associated forecasts and to align those forecasts with an event level in the Event Level Matrix. At each event level, there is a correlation between the number of trouble spots and a range of resource needs for that particular weather impact. The Event Level Matrix is founded on key operational assumptions, including the number of available internal and affiliate crews typically available, typical restoration work durations and expected crew productivity during extended storm operations. As event severity increases, the response organization and resource commitments scale accordingly, including the addition of external mutual assistance and contractor resources as needed. Once the actual extent of the damage is known in terms of the nature and scope of the damage, then the Company can scale its crew resources to “correlate” with the number of known trouble spots and other necessary response actions. The ERP Event Level Matrix serves as the foundational planning tool, while the Incident Management Team (“IMT”) applies operational experience and expertise to evaluate weather
  2. Page 2 of 30

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set OCC-13 Date Issued September 02, 2026 OCC-544 Page 2 of 2 forecasts, system conditions, damage information, resource availability, regional and operational constraints. Based on this collective experience and situational awareness, the IMT refines the resource plan and determines the appropriate staging locations, crew allocations, and staffing strategy necessary to support safe and efficient restoration efforts.
  3. Page 3 of 30

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set OCC-13 Date Issued September 02, 2026 OCC-545 Page 1 of 3 Date Filed: September 16, 2026 Witness: Donald J. Scacco Jr., Christopher E. Colorio, and Mark P. Baldwin Request from: Office of Consumer Counsel Question: Referring to Exhibit CLP-STORM-1 at 61-62, 75. The Company concludes that its decisionmaking was reasonable under the circumstances and that the costs were necessary. Please identify any alternative resource plans considered and explain how cost, restoration time, and risk informed the plan selected. Response: The Company’s decision making is guided by the Emergency Response Plan (“ERP”), which is the PURA-approved framework for emergency response and restoration. The ERP is founded on a principle of scalability to align with the nature and scope of the emergency event. Based on the best information reasonably available at the time, the Company develops an event-specific resource plan using the ERP Event Level Matrix (“ELM”). The ELM adheres to the National Incident Management System (“NIMS”) event level classification structure to provide the Company with the ability to scale its emergency response appropriately to the forecasted and actual damage on the electric system. The Company incurs costs to prepare for an oncoming storm system; to respond to public-safety priorities; and to restore customer outages, among other activities for the benefit of customers and local communities. Please refer to Exhibit CLPSTORM-1, at 29-30. Public Act 12-148, An Act Enhancing Emergency Preparedness and Response, requires that ERPs address plans for restoring power to 10%, 30%, 50% and 70% of EDC customers. Within the context of the ELM, a resource plan is developed and deployed. As stated in PURA Docket No. 12-06-09 PURA Establishment Of Performance Standards For Electric And Gas Companies – Final Decision, Appendix A, “[i]n addition to submitting its ERP to the PURA for reviews of emergency plans every two years, on or before July 1st, pursuant to the General Statutes of Connecticut (Conn. Gen. Stat.) §16-32e, each EDC will also file the ERP in full when there have been any material changes in the ERP.” The ERP and ELM do not prescribe a single, fixed resource plan for each emergency event. Rather, these guidelines provide a framework for developing an event-specific resource plan based on the information available concerning the anticipated or actual scope of damage, resource availability, and other circumstances. Depending on the circumstances, the Company may use varying levels of resources and, as additional information becomes available, the Company adjusts its resource deployment plan as appropriate and necessary.
  4. Page 4 of 30

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set OCC-13 Date Issued September 02, 2026 OCC-545 Page 2 of 3 In this context, meeting public-safety needs, minimizing restoration time, and risk assessment are considered together rather than independently. As discussed in the Company’s response to OCC556 i, when procuring external resources, the Company balances cost considerations with the paramount goal of restoring service safely, efficiently and as quickly as possible. The primary decision point is the number and deployment of field crews and support personnel, and there is only one resource plan that is created for purposes of a storm event, which is captured in the Incident Action Plans (“IAP”). However, to create the IAP, numerous decisional factors are involved, and the resource plan will continually evolve through the event based on those decisional factors. In essence, any alternative plan would simply involve fewer crews at a longer restoration time or more crews. Decision points include: Type, scale and timing of weather event expected Confidence level of forecast projections Availability of field crews and the presence of regional need. Skill sets, skill levels, reliability, capabilities and proximity of field crews Number, type and location of forecasted and actual outage and non-outage trouble events and public safety Logistical circumstances Weather circumstances and mobility during restoration Status of internal considerations identified for employees and company systems and equipment Status of external considerations identified by external stakeholders The Company’s decisions in response to the 2024-2025 Storm Events were made within the established ERP and ELM framework and incorporated consideration of the circumstances at the time of each decision. The costs incurred were associated with the resources determined to be reasonably necessary at the time to support safe, efficient, and timely restoration of electric service to the customers, taking into account expected restoration timelines, resource availability, and cost. Across all its decision making, risks such as an unsafe, inefficient or unreasonably prolonged restoration are constantly evaluated. i OCC-556 Question: Referring to Exhibit CLP-STORM-1 at 41. The Company states that it secures the closest available resources to minimize travel time and reduce cost. Please provide comparable rates for contractors, affiliates and mutual-aid crews, and explain how proximity and cost informed resource selection.
  5. Page 5 of 30Match

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set OCC-13 Date Issued September 02, 2026 OCC-545 Page 3 of 3 OCC-556 Response: When the Company procures external crews to support storm restoration, it evaluates several interrelated factors. The relative importance of each factor depends on the specific circumstances of the storm event. Generally, these factors include: 1. Whether the storm is a regional event. When a storm affects a broader geographic region, utilities may face increased demand and competition for available contractor resources. This can affect both the availability and cost of external crews and may require the Company to make procurement decisions within a limited timeframe. 2. The quantity and type of resources required. The Company determines the quantity and type of external resources needed by considering weather forecasts, anticipated damage, current system conditions, available internal resources, and other relevant information at the time of procurement. The Company’s resource requirements may change as more information about the storm and its impact becomes available. 3. The location and availability of crews. The Company evaluates the location of available crews in relation to its service territory and their ability to mobilize within the necessary timeframe. The proximity of available crews often plays a key role, as crews closer to the service area can typically mobilize faster and charge lower mobilization and demobilization costs. 4. The unit rate and overall cost. The Company considers the unit rate or other applicable pricing for each available crew but does not evaluate the unit rate in isolation. Instead, it considers the anticipated total cost of securing and deploying a crew, including mobilization, demobilization, travel, and other relevant costs. When procuring external resources, the Company balances cost considerations with the importance of restoring service safely, efficiently, and as quickly as possible. Accordingly, the crew with the lowest unit rate may not always represent the lowest total cost or the most suitable resource overall. For example, the Company may secure a crew located closer to its service territory, even if that crew has a higher unit rate than one farther away. A nearby crew may have significantly lower mobilization and demobilization costs and can often begin restoration work sooner. When these factors are considered together, the total cost for the closer crew may be less than that of a more distant crew, despite the higher unit rate. Conversely, during a regional storm event when nearby resources are in high demand or unavailable, the Company may find it necessary or more reasonable to procure crews from farther away. While the Company frequently will prioritize the closest available resources to minimize travel time and reduce costs, it does not select contractors based on a single factor. Instead, the Company reviews all available information and the unique circumstances of each storm event to identify the resource mix that best supports safe, efficient, and timely restoration while accounting for overall cost.
  6. Page 6 of 30

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set OCC-13 Date Issued September 02, 2026 OCC-546 Page 1 of 2 Date Filed: September 16, 2026 Witness: Donald J. Scacco Jr., Christopher E. Colorio, and Mark P. Baldwin Request from: Office of Consumer Counsel Question: For each storm event in the proposal, please provide every resource plan prepared before or during the event, each significant revision, and the contemporaneous approval of any change to the event level or commitment of external crews. Identify the date, time, decisionmaker, resources affected, and reason for each decision. For each storm event in the proposal, please provide every resource plan prepared before or during the event, each significant revision, and the contemporaneous approval of any change to the event level or commitment of external crews. Identify the date, time, decision-maker, resources affected, and reason for each decision. Response: Resource plans are not static and are actively scaled during preparedness and response activities to the appropriate Emergency Response Plan (“ERP”) event level based on the Event Level Matrix (“ELM”). Activities are based on the best available information at the time and are subject to adjustment due to changing conditions, forecasts, and the status and duration of customer outages. Information supporting resource mobilization, demobilization and deployment are tracked in the Incident Action Plan, which is prepared during an event with a frequency depending on the scale of the event and specific circumstances. In Exhibit CLP-STORM-IMT-3 for each storm event, the Company provided the time-stamped Incident Action Plan for each event, which includes: Event summary chart Primary weather forecasts and reports Incident Action Plan, including o Summaries of specific weather conditions o Detailed Restoration Status o Damage Prediction o ERP Classification & Activation o IMT Objectives for the Planning Period o Event Communications o Damage Assessment o Resource Assessment o Restoration Crews Working By Town
  7. Page 7 of 30

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set OCC-13 Date Issued September 02, 2026 OCC-546 Page 2 of 2 o Resource Assessment & Strategy o Logistics & Catering o Safety
  8. Page 8 of 30

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set OCC-13 Date Issued September 02, 2026 OCC-547 Page 1 of 2 Date Filed: September 16, 2026 Witness: Donald J. Scacco Jr., Christopher E. Colorio, and Mark P. Baldwin Request from: Office of Consumer Counsel Question: Referring to Exhibit CLP-STORM-1 at 28. The Company states that outage-model accuracy depends on the quality and confidence of the weather forecasts used as inputs. For each event, provide each weather and outage forecast, actual results, forecast errors, and vendor or model accuracy evaluations. Response: Please refer to Exhibit CLP-IMT-3 for each storm event. The Company receives weather and outage forecasts from multiple forecasting providers and tools that produce a broad range of meteorological parameters and outage projections across the Company's entire service territory. These forecasts are highly dynamic and are routinely updated numerous times before and during an event as weather conditions evolve and additional information becomes available. In addition, both weather forecasts and outage forecasts are probabilistic, rather than deterministic in nature. The forecasts are intended to provide a range of potential outcomes and associated confidence levels based on the best available information at a given point in time, not to predict a single, precise result. As conditions change and forecast uncertainty is reduced or increased, projected weather impacts and outage estimates may change significantly throughout the event's lifecycle. The Company continuously evaluates forecast updates in conjunction with actual system conditions, observed damage, customer outage counts, field assessments, and restoration progress. Based on this ongoing assessment, the Company adjusts staffing levels, contractor requests, resource staging locations, restoration plans, and other operational decisions as appropriate. A retrospective validation study comparing forecasted and actual outcomes on an event-by-event basis would be extremely difficult to perform and would provide limited practical value. Each weather event is unique with respect to storm track, wind speed and duration, precipitation type and intensity, antecedent conditions, vegetation characteristics, asset exposure, and other factors that influence system impacts. Additionally, both weather forecasts and outage projections are iterative products that may change numerous times throughout the event lifecycle. As a result, any comparison of a single forecast to actual outcomes would not adequately reflect how forecasts are used operationally or the evolving nature of event response decision-making. The UConn OPM,
  9. Page 9 of 30

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set OCC-13 Date Issued September 02, 2026 OCC-547 Page 2 of 2 for example, is continuously updated by UConn to incorporate new data and modeling enhancements intended to improve forecast performance over time. To the extent the request seeks vendor evaluations of model performance, the Company is relying on premier weather forecasting services and sources, including weather reports prepared by the National Weather Service, the State of Connecticut Department of Emergency Management and Homeland Security and several commercial services. Understanding the track record of “accuracy” associated with these sources would provide no value to the Company as “inaccuracy” in the past says nothing about the future, as every event is different and forecasts may be “inaccurate” simply because actual forces of nature behaved differently than forecast, even by sophisticated models not because the model is inherently flawed. No weather forecast is 100% accurate, and weather forecasts do not approach 100% predictive before the actual weather event is occurring whereas the Company needs to be prepared in advance of the onset of the storm event. Event specific assessments of model accuracy were provided in OCC-547, Attachment 1 CONFIDENTIAL through OCC-547, Attachment 6 CONFIDENTIAL, in relation to the UCONN damage prediction model.
  10. Page 10 of 30

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set OCC-13 Date Issued September 02, 2026 OCC-548 Page 1 of 1 Date Filed: September 16, 2026 Witness: Donald J. Scacco Jr., Christopher E. Colorio, and Mark P. Baldwin Request from: Office of Consumer Counsel Question: Referring to Exhibit CLP-STORM-1 at 29-30. The Company states that event levels may be modified as conditions and actual impacts become better understood. For events with impacts below forecast, please explain how the event level and resource plan were reassessed as conditions developed. Response: The Company prepares for an ERP event based on weather forecasts, the potential severity and timing of the event, and other relevant information reasonably available to the Company at the time the relevant decisions are made. As the weather system develops, actual storm impacts may differ from earlier forecasts. There are many variables that can change, including but not limited to: pressure gradient, storm track and intensity, forward speed, timing and movement of frontal boundaries, wind speeds (sustained and gusts), precipitation type and totals, radial ice accretion totals, ambient temperatures, atmospheric instability, soil moisture and ground saturation conditions, river and stream levels, storm duration, geographic extent of impacts, and the interaction of local and mesoscale weather features. Any variation in these factors can significantly affect the timing, location, severity and overall impacts of the event. No weather forecast is 100% accurate. Therefore, the Company will err on the side of caution when impacts appear to be below forecast and maintain preparedness as weather conditions are observed. Once weather forecasts are published with new information, impacts are directly observable and the threat has passed, the Company takes steps to adjust the resource plan, including consideration of the deployment and/or demobilization of on-site resources.

Text of OCC Set 12_COMBINED.pdf

Extracted from the file · 73 pages · 193,636 characters

Text of OCC Set 11_COMBINED.pdf

Extracted from the file · 48 pages · 62,469 characters

Text of OCC Set 10_COMBINED.pdf

Extracted from the file · 51 pages · 90,368 characters

Text of OCC Set 5_COMBINED.pdf

Extracted from the file · 46 pages · 88,105 characters

Text of OCC Set 4_COMBINED.pdf

Extracted from the file · 159 pages · 268,038 characters

Text of OCC Set 3_COMBINED.pdf

Extracted from the file · 93 pages · 113,517 characters

Text of OCC Set 2_COMBINED.pdf

Extracted from the file · 68 pages · 113,929 characters

Text of OCC Set 1_COMBINED.pdf

Extracted from the file · 139 pages · 225,320 characters

Text of OCC Set 14_COMBINED.pdf

Extracted from the file · 66 pages · 143,197 characters

As listed on the current system

Corres. 09/29/2026 [26-05-10] (Keegan Werlin LLP) - Compilations of discovery responses

This filing on the current system (opens in a new tab)