Compilations of discovery responses
Files31
Docket No. 26-05-10 Discovery Compilations September 29 2026.pdf
PDF · 161 KB · 2 pagesText searchable
Download Docket No. 26-05-10 Discovery Compilations September 29 2026.pdfRead the text of Docket No. 26-05-10 Discovery Compilations September 29 2026.pdf
ALLCO Set 5_COMBINED.pdf
PDF · 669 KB · 36 pagesText searchable
Download ALLCO Set 5_COMBINED.pdfRead the text of ALLCO Set 5_COMBINED.pdf
ALLCO Set 4_COMBINED.pdf
PDF · 133 KB · 4 pagesText searchable
Download ALLCO Set 4_COMBINED.pdfRead the text of ALLCO Set 4_COMBINED.pdf
ALLCO Set 3_COMBINED.pdf
PDF · 346 KB · 23 pagesText searchable
Download ALLCO Set 3_COMBINED.pdfRead the text of ALLCO Set 3_COMBINED.pdf
ALLCO Set 2_COMBINED.pdf
PDF · 576 KB · 38 pagesText searchable
Download ALLCO Set 2_COMBINED.pdfRead the text of ALLCO Set 2_COMBINED.pdf
ALLCO Set 1_COMBINED.pdf
PDF · 458 KB · 27 pagesText searchable
Download ALLCO Set 1_COMBINED.pdfRead the text of ALLCO Set 1_COMBINED.pdf
ALLCO Set 6_COMBINED.pdf
PDF · 332 KB · 9 pagesText searchable
Download ALLCO Set 6_COMBINED.pdfRead the text of ALLCO Set 6_COMBINED.pdf
AMTRAK Set 2_COMBINED.pdf
PDF · 123 KB · 2 pagesText searchable
Download AMTRAK Set 2_COMBINED.pdfRead the text of AMTRAK Set 2_COMBINED.pdf
AMTRAK Set 1_COMBINED.pdf
PDF · 190 KB · 5 pagesText searchable
Download AMTRAK Set 1_COMBINED.pdfRead the text of AMTRAK Set 1_COMBINED.pdf
AMTRAK Set 3_COMBINED.pdf
PDF · 649 KB · 34 pagesText searchable
Download AMTRAK Set 3_COMBINED.pdfRead the text of AMTRAK Set 3_COMBINED.pdf
CIEC Set 2_COMBINED.pdf
PDF · 85 KB · 1 pageText searchable
Download CIEC Set 2_COMBINED.pdfRead the text of CIEC Set 2_COMBINED.pdf
CIEC Set 1_COMBINED.pdf
PDF · 351 KB · 19 pagesText searchable
Download CIEC Set 1_COMBINED.pdfRead the text of CIEC Set 1_COMBINED.pdf
CIEC Set 3_COMBINED.pdf
PDF · 188 KB · 4 pagesText searchable
Download CIEC Set 3_COMBINED.pdfRead the text of CIEC Set 3_COMBINED.pdf
CLF-SC Set 1_COMBINED.pdf
PDF · 611 KB · 56 pagesText searchable
Download CLF-SC Set 1_COMBINED.pdfRead the text of CLF-SC Set 1_COMBINED.pdf
CLF Set 1_ COMBINED.pdf
PDF · 289 KB · 20 pagesText searchable
Download CLF Set 1_ COMBINED.pdfRead the text of CLF Set 1_ COMBINED.pdf
CLF-SC Set 2_COMBINED.pdf
PDF · 182 KB · 7 pagesText searchable
Download CLF-SC Set 2_COMBINED.pdfRead the text of CLF-SC Set 2_COMBINED.pdf
EOE Set 3_COMBINED.pdf
PDF · 237 KB · 11 pagesText searchable
Download EOE Set 3_COMBINED.pdfRead the text of EOE Set 3_COMBINED.pdf
EOE Set 2_COMBINED.pdf
PDF · 417 KB · 22 pagesText searchable
Download EOE Set 2_COMBINED.pdfRead the text of EOE Set 2_COMBINED.pdf
EOE Set 1_COMBINED.pdf
PDF · 1.7 MB · 200 pagesText searchable
Download EOE Set 1_COMBINED.pdfRead the text of EOE Set 1_COMBINED.pdf
EOE Set 4_COMBINED.pdf
PDF · 836 KB · 70 pagesText searchable
Download EOE Set 4_COMBINED.pdfRead the text of EOE Set 4_COMBINED.pdf
ICC Set 1_COMBINED.pdf
PDF · 466 KB · 30 pagesText searchable
Download ICC Set 1_COMBINED.pdfRead the text of ICC Set 1_COMBINED.pdf
OCC Set 13_COMBINED.pdf
PDF · 484 KB · 30 pagesText searchable
Download OCC Set 13_COMBINED.pdfRead the text of OCC Set 13_COMBINED.pdf
OCC Set 12_COMBINED.pdf
PDF · 1.0 MB · 73 pagesText searchable
Download OCC Set 12_COMBINED.pdfRead the text of OCC Set 12_COMBINED.pdf
OCC Set 11_COMBINED.pdf
PDF · 482 KB · 48 pagesText searchable
Download OCC Set 11_COMBINED.pdfRead the text of OCC Set 11_COMBINED.pdf
OCC Set 10_COMBINED.pdf
PDF · 542 KB · 51 pagesText searchable
Download OCC Set 10_COMBINED.pdfRead the text of OCC Set 10_COMBINED.pdf
OCC Set 5_COMBINED.pdf
PDF · 511 KB · 46 pagesText searchable
Download OCC Set 5_COMBINED.pdfRead the text of OCC Set 5_COMBINED.pdf
OCC Set 4_COMBINED.pdf
PDF · 1.3 MB · 159 pagesText searchable
Download OCC Set 4_COMBINED.pdfRead the text of OCC Set 4_COMBINED.pdf
OCC Set 3_COMBINED.pdf
PDF · 1.2 MB · 93 pagesText searchable
Download OCC Set 3_COMBINED.pdfRead the text of OCC Set 3_COMBINED.pdf
OCC Set 2_COMBINED.pdf
PDF · 1.7 MB · 68 pagesText searchable
Download OCC Set 2_COMBINED.pdfRead the text of OCC Set 2_COMBINED.pdf
OCC Set 1_COMBINED.pdf
PDF · 7.0 MB · 139 pagesText searchable
Download OCC Set 1_COMBINED.pdfRead the text of OCC Set 1_COMBINED.pdf
OCC Set 14_COMBINED.pdf
PDF · 880 KB · 66 pagesText searchable
Download OCC Set 14_COMBINED.pdfRead the text of OCC Set 14_COMBINED.pdf
Text of ALLCO Set 3_COMBINED.pdf
Extracted from the file · 23 pages · 55,777 characters
Text of ALLCO Set 2_COMBINED.pdf
Extracted from the file · 38 pages · 81,182 characters
Text of ALLCO Set 1_COMBINED.pdf
Extracted from the file · 27 pages · 46,644 characters
Text of ALLCO Set 6_COMBINED.pdf
Extracted from the file · 9 pages · 18,340 characters
Text of AMTRAK Set 2_COMBINED.pdf
Extracted from the file · 2 pages · 3,025 characters
Text of AMTRAK Set 1_COMBINED.pdf
Extracted from the file · 5 pages · 4,881 characters
Text of AMTRAK Set 3_COMBINED.pdf
Extracted from the file · 34 pages · 101,991 characters
Text of CIEC Set 2_COMBINED.pdf
Extracted from the file · 1 page · 1,005 characters
Text of CIEC Set 1_COMBINED.pdf
Extracted from the file · 19 pages · 26,023 characters
Text of CIEC Set 3_COMBINED.pdf
Extracted from the file · 4 pages · 5,355 characters
Text of CLF-SC Set 1_COMBINED.pdf
Extracted from the file · 56 pages · 132,578 characters
Text of CLF Set 1_ COMBINED.pdf
Extracted from the file · 20 pages · 38,243 characters
Text of CLF-SC Set 2_COMBINED.pdf
Extracted from the file · 7 pages · 17,131 characters
Text of EOE Set 3_COMBINED.pdf
Extracted from the file · 11 pages · 23,418 characters
Text of EOE Set 2_COMBINED.pdf
Extracted from the file · 22 pages · 42,455 characters
Text of EOE Set 1_COMBINED.pdf
Extracted from the file · 200 pages · 332,382 characters
Text of EOE Set 4_COMBINED.pdf
Extracted from the file · 70 pages · 139,575 characters
Text of ICC Set 1_COMBINED.pdf
Extracted from the file · 30 pages · 51,093 characters
Text of OCC Set 13_COMBINED.pdf
Extracted from the file · 30 pages · 61,971 characters
Text of OCC Set 12_COMBINED.pdf
Extracted from the file · 73 pages · 193,636 characters
Text of OCC Set 11_COMBINED.pdf
Extracted from the file · 48 pages · 62,469 characters
Page 35 of 51
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set OCC-10 Date Issued August 25, 2026 OCC-473 Page 1 of 1 Date Filed: September 15, 2026 Witness: Edward A. Davis and Kimberly R. Parsons Request from: Office of Consumer Counsel Question: (Rate 6 – Residential Space Heating Rate) Refer to Exhibit CLP-RATES-1, at 23-24. Please state whether the Revenue Decoupling Mechanism is designed to capture any revenue shortfall arising from Rate 6 enrollment diluting Rate 1 revenues. If so, explain how Rate 6-driven revenue loss will be treated under the RDM and which customer classes ultimately bear that cost. Response: The Revenue Decoupling mechanism is designed to reconcile differences in aggregated (i.e.,. total) actual vs. targeted revenues, and not specifically to capture such revenue shortfall that may occur. While the question does not define or explain what is meant by diluted revenues, if the context of an assumed difference in revenue is due to the migration of Rate 1 customers to Rate 6, such migration may in a given month result in higher revenue for first block kWh sales, and lower revenue for second block kWh sales, which potentially include both kWh sales that would otherwise have been charged under Rate 1 and kWh sales associated with incremental, new heat pump load. The Company does not agree that Rate 6 enrollment which reflects increased kWh sales would reduce overall revenue compared with revenue under Rate 1 which would exclude such increased kWh sales.Page 36 of 51
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set OCC-10 Date Issued August 25, 2026 OCC-474 Page 1 of 1 Date Filed: September 08, 2026 Witness: Edward A. Davis and Kimberly R. Parsons Request from: Office of Consumer Counsel Question: (Rate 6 – Residential Space Heating Rate) Please explain how the two volumetric discount levels (4.7 cents/kWh for heating season usage above 700 kWh and 2.8 cents/kWh for all other usage) were derived. Specifically: a. Were the discounts calibrated to the incremental cost of serving heat pump load? If so, please provide the calculation and workpapers in live Excel format with all formulas intact. If not, why not? b. Did the Company consider other discount levels? If so, explain the alternatives considered and why they were ruled out. If not, why not? Response: a. Please refer to Exhibit CLP-RATES-6, at page 2. An Excel version of that exhibit was provided as part of the Company’s filing. Costs and the associated proposed incremental load rate is calibrated with the marginal cost of providing service, as detailed on page 2 of the exhibit. b. Please note, the Company did not develop the 2.8 cents/kWh rate as a discount from the 4.7 cents/kWh rate, so no other level of discount was considered. Rather, the Winter Block 2 Rate is based on the marginal cost of service and reconciling adjustments that allocate a proportional share of the corresponding volumetric rate, as detailed in Exhibit CLP-RATES-6, at page 2.Page 37 of 51
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set OCC-10 Date Issued August 25, 2026 OCC-475 Page 1 of 2 Date Filed: September 08, 2026 Witness: Edward A. Davis and Kimberly R. Parsons Request from: Office of Consumer Counsel Question: (Rate 6 – Residential Space Heating Rate) Refer to Exhibit CLP-RATES-1, at 35-36, which acknowledges that incremental load from EV charging can also benefit from the Rate 6 discount for usage above 700 kWh. a. Was the discount sized to account for this “free rider” effect? If so, how? If not, why not? b. What percentage of Rate 6 enrollees does the Company expect to also have EV charging load? c. Has the Company modeled the revenue impact if a significant share of Rate 6 bill savings is attributable to EV charging rather than heat pump load? If so, provide the associated workpapers in live Excel format with all formulas intact. If not, why not? Response: a. Yes. The Winter Block 2 rate for Rate 6 is based on marginal distribution costs and a reconciling adjustment that effectively marks up the rate on an average load basis to ensure an additional share of demand related distribution costs are charged to incremental load (please refer to the Company’s response to OCC-474 i). As a prerequisite to the rate, a customer must add new heat pump load not already included in the underlying revenue requirement applied in the rate design for Rate 1. By moving fixed cost recovery into the customer charge and the “tier 1” volumetric rates for Distribution, the Winter Block 2 rate that applies to incremental load, whether primarily for the heat pump load or secondarily any other incremental load, we are pricing that block based on, but above marginal cost to ensure positive contribution to distribution costs. Pricing for other components of service including transmission, public benefits and supply are unchanged relative to Rate 1. This helps mitigate the free rider effect. b. The Company does not have such an estimate. c. The Company has not conducted such an analysis. The workpapers provided in Exhibit CLP-RATES-6 may be utilized to estimate bill impacts for various levels of usage, which may be assumed to include incremental heat pump and EV charging load.Page 38 of 51
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set OCC-10 Date Issued August 25, 2026 OCC-475 Page 2 of 2 Prior Referenced Response: i OCC-474 Question: (Rate 6 – Residential Space Heating Rate) Please explain how the two volumetric discount levels (4.7 cents/kWh for heating season usage above 700 kWh and 2.8 cents/kWh for all other usage) were derived. Specifically: a. b. Were the discounts calibrated to the incremental cost of serving heat pump load? If so, please provide the calculation and workpapers in live Excel format with all formulas intact. If not, why not? Did the Company consider other discount levels? If so, explain the alternatives considered and why they were ruled out. If not, why not? OCC-474 Response: a. Please refer to Exhibit CLP-RATES-6, at page 2. An Excel version of that exhibit was provided as part of the Company’s filing. Costs and the associated proposed incremental load rate is calibrated with the marginal cost of providing service, as detailed on page 2 of the exhibit. b. Please note, the Company did not develop the 2.8 cents/kWh rate as a discount from the 4.7 cents/kWh rate, so no other level of discount was considered. Rather, the Winter Block 2 Rate is based on the marginal cost of service and reconciling adjustments that allocate a proportional share of the corresponding volumetric rate, as detailed in Exhibit CLP-RATES-6, at page 2.Page 39 of 51
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set OCC-10 Date Issued August 25, 2026 OCC-476 Page 1 of 2 Date Filed: September 08, 2026 Witness: Edward A. Davis and Kimberly R. Parsons Request from: Office of Consumer Counsel Question: (Rate 6 – Residential Space Heating Rate) Refer to Exhibit CLP-RATES-1, at 36, which states that “additional EV charging during winter months can benefit from and contribute to system efficiency while receiving the benefit of reduced costs reflective of the heating season.” a. If the Company believes that EV charging load can provide the same system benefits as heat pump load during winter months, why did the Company not propose that EV charging customers without heat pumps be eligible for Rate 6? b. Explain whether the Company believes that it is reasonable, from a cost causation and revenue neutrality perspective, for EV charging load to receive a discount during the winter without having to pay higher rates in the summer. Response: a. Rate 6 is designed for incremental winter load associated with adding a heat pump. However, the Company has no way of specifically identifying or differentiating such incremental heat pump load from other incremental load. Moreover, as with other residential rates this design is predicated on annual revenue requirements and average rates, that apply to whole house service. The design of Rate 6 is structured to ensure that the rate applies to the relevant period and includes the incremental load of the heat pump operating during the winter period, and increased system utilization may occur. The primary focus of this rate design is on space heating, and the comparative load that informs characteristics of this incremental load (i.e., that associated with electric space heating, not EV’s) is a comparison of Rate 5 vs. Rate 1 monthly usage. b. On balance the proposal provides a Distribution rate that can support incremental load during the winter period beyond that of heat pumps operating in a heating mode. This rate is not predicated on achieving an overall annual average rate that, due to a reduction in the rate for one period, an offsetting higher rate is required in another period. To ensure revenue neutrality with load across all months prior to consideration of any load increase in the targeted winter period, the proposed design moves a significant share of cost recovery, into the customer charge and the block 1 rate. This facilitates pricing for the incremental load using marginal costs, as fully detailed in Exhibit CLP-RATES 6.Page 40 of 51
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set OCC-10 Date Issued August 25, 2026 OCC-476 Page 2 of 2 It is important to note that comparative load shapes of Rate 1 and Rate 5 indicate that both classes have increased electric load in the summer compared with the average, and while it hasn’t been evaluated, the incremental load during the summer associated with a new heat pump added for electric space heating may already be represented in the summer load characteristics of Rate 1, with no incremental impact to cost of service or average distribution rates. Adding an EV load during the summer would represent an incremental load, and may drive additional costs relative to cooling loads already reflected in such rates. The Rate 7 timeof-day structure offers price signals whereby rates for incremental EV charging load during the summer would be expected to be lower during off-peak periods, and would therefore provide incentive to charge during the off peak and avoid causing additional costs. Given the nature of the Rate 6 design, the Company did not evaluate redesigning rates applicable to the summer period.Page 41 of 51
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set OCC-10 Date Issued August 25, 2026 OCC-477 Page 1 of 1 Date Filed: September 08, 2026 Witness: Edward A. Davis and Kimberly R. Parsons Request from: Office of Consumer Counsel Question: (Rate 6 – Residential Space Heating Rate) Refer to Exhibit CLP-RATES-6, which shows that the Rate 6 customer charge is $30.95/month, in contrast to the Rate 1 customer charge of $12.36/month. Please explain how the differences in volumetric and customer charges between Rate 1 and Rate 6 were determined and whether the higher customer charge on Rate 6 was designed to offset the volumetric discount on a revenue-neutral basis. Provide the associated workpapers in live Excel format with all formulas intact. Response: Please refer to Exhibit CLP-RATES-6, at pages 2-3, for details of both the development of the Rate 6 customer charge and volumetric rates and differences between those and their Rate 1 counterparts. The disaggregation and reallocation of Distribution revenue requirements to the customer charge and block 1 volumetric rate provides the revenue neutral rate design for existing load upon which Rate 1 is designed. The higher customer charge does not reflect a discount to the rate associated with incremental load but rather recovers the share of revenue requirement for load of the class prior to any incremental load. It is set at the marginal customer cost, and in doing so effectively reduces the volumetric rate for the usage associated with only the revenue neutral design. The resulting volumetric rate provides a basis by which to evaluate the design of rates for incremental heat pump load, as shown in the page 2 of the exhibit.Page 42 of 51
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set OCC-10 Date Issued August 25, 2026 OCC-478 Page 1 of 2 Date Filed: September 08, 2026 Witness: Edward A. Davis and Kimberly R. Parsons Request from: Office of Consumer Counsel Question: (Rate 6 – Residential Space Heating Rate) Did the Company consider other rate structures to incentivize heat pump adoption, such as a seasonal TOU rate? If so, provide the alternatives considered and explain why each alternative was ruled out. If not, why not? Response: Yes. The Company’s considerations included a modified version of our current residential TOU rate structure incorporating 2-block and 3-block structures and potentially seasonal adjustments, a straight 3-tier block rate structure and a straight discounted rate structure. The Company also considered which of the various components of rates might be candidates for these alternatives. All alternatives were considered applied as a “whole house” rate, whereby the heat pump load is not a separately metered service or subject to its own separate treatment as a potential rate class. There is no explicit regulatory directive to offer these or other structures, and application of a straight discount rate as has been applied in other jurisdictions raised the prospect of pure discounts with no explicit basis in utility cost of providing service as initial considerations. The Company currently offers a residential TOU rate that it believes provides presents time varying price signals that customers can easily understand and may wish to utilize for adding and operating a new heat pump, and to extend further for other uses in their home, should they choose to manage usage on a TOU (time of day) basis. With an already substantial, annualized time of day price differential, incorporate a seasonal structure adds significant complexity, especially where such seasonality would need to be evaluated extensively and have the greatest potential impact on supply, transmission and public benefits components of rates. The concept of a block rate structure is not new, but rather is informed by previous experience with block rates for new load associated with water heaters and other end use devices. The Company has developed a variation of this approach tailored to support service to incremental heat pump load during winter months. A 3-block structure alone is difficult to apply given variability and inability to measure or standardized heat pump load blocks, and simply not possible to implement. Incorporating a block rate into the current TOU rate structure is very complex and rejected based on the expectation of causing significant customer confusion. Moreover, such a structure is not feasible and impractical to implement. However, the Company believes the current TOU rate remains an option that customers may be interested in when considering heat pump adoption.Page 43 of 51
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set OCC-10 Date Issued August 25, 2026 OCC-478 Page 2 of 2 A primary goal in offering Rate 6 is to provide an understandable and implementable solution that provides immediate benefits to customers adopting heat pump technologies, including providing a rate offering that supports affordability of electric service. The seasonal, 2-block rate structure fits within the framework of existing rate structures (i.e., Rate 1) and targets incremental heating load of new heat pumps for non-electric space heating customers. While there is no way to know and specifically measure what portions of prospective, incremental load are from heat pumps, narrowing the rate design to a 2nd tier during winter periods helps further focus special rates on incremental heat pump load. A straight discount on all kWh rates for many components of service can significantly shift costs to other customers. While proposed Rate 6 provides a lower rate for only the Distribution component of service, it does not simply discount and shift cost recovery to other customers or for an overly broad period for other components of service, and being cost based, closely targets its intended application, incremental heating season load. With Rate 7 TOU rate as one option, the structure presented under proposed Rate 6 provides a simple and beneficial alternative for customers that can be implemented at the conclusion of this case, using current metering and billing capabilities, systems and processes.Page 44 of 51
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set OCC-10 Date Issued August 25, 2026 OCC-479 Page 1 of 1 Date Filed: September 15, 2026 Witness: Edward A. Davis and Kimberly R. Parsons Request from: Office of Consumer Counsel Question: (Rate 6 – Residential Space Heating Rate) Please provide the Company’s summer and winter peak load by customer class under a normal weather scenario, including historical hourly system load data for the past three years. Please also provide: a. Average hourly load by month and season for the residential class b. Coincident peak contribution by customer class for summer and winter peaks. Response: Please refer to OCC-479, Attachment 1, for the Company’s peak load by rate class and coincident peak contribution by rate class for 2023-2025. Please refer to OCC-479, Attachment 2, for the historical hourly load for each rate class for 20232025. Please refer to OCC-479, Attachment 3, for the average hourly load for the residential rate class for the 2023-2025. Note that the data provided is not weather normalized and is provided by rate class. Data has been derived from load research analyses, which rely on extrapolations of sample data for many of the rate classes provided in the attachments, including Residential Rates 1 and 5, and small general service Rates 30 and 35).
Text of OCC Set 5_COMBINED.pdf
Extracted from the file · 46 pages · 88,105 characters
Text of OCC Set 4_COMBINED.pdf
Extracted from the file · 159 pages · 268,038 characters
Text of OCC Set 3_COMBINED.pdf
Extracted from the file · 93 pages · 113,517 characters
Text of OCC Set 2_COMBINED.pdf
Extracted from the file · 68 pages · 113,929 characters
Text of OCC Set 1_COMBINED.pdf
Extracted from the file · 139 pages · 225,320 characters
Text of OCC Set 14_COMBINED.pdf
Extracted from the file · 66 pages · 143,197 characters
As listed on the current system
Corres. 09/29/2026 [26-05-10] (Keegan Werlin LLP) - Compilations of discovery responses