Skip to main content

A prototype public docket site for the Connecticut Public Utilities Regulatory Authority

Utility Dockets and Filings

Compilations of discovery responses

Files31

Text of ALLCO Set 3_COMBINED.pdf

Extracted from the file · 23 pages · 55,777 characters

Text of ALLCO Set 2_COMBINED.pdf

Extracted from the file · 38 pages · 81,182 characters

Text of ALLCO Set 1_COMBINED.pdf

Extracted from the file · 27 pages · 46,644 characters

Text of ALLCO Set 6_COMBINED.pdf

Extracted from the file · 9 pages · 18,340 characters

Text of AMTRAK Set 2_COMBINED.pdf

Extracted from the file · 2 pages · 3,025 characters

Text of AMTRAK Set 1_COMBINED.pdf

Extracted from the file · 5 pages · 4,881 characters

Text of AMTRAK Set 3_COMBINED.pdf

Extracted from the file · 34 pages · 101,991 characters

Text of CIEC Set 2_COMBINED.pdf

Extracted from the file · 1 page · 1,005 characters

Text of CIEC Set 1_COMBINED.pdf

Extracted from the file · 19 pages · 26,023 characters

Text of CIEC Set 3_COMBINED.pdf

Extracted from the file · 4 pages · 5,355 characters

Text of CLF-SC Set 1_COMBINED.pdf

Extracted from the file · 56 pages · 132,578 characters

Text of CLF Set 1_ COMBINED.pdf

Extracted from the file · 20 pages · 38,243 characters

Text of CLF-SC Set 2_COMBINED.pdf

Extracted from the file · 7 pages · 17,131 characters

Text of EOE Set 3_COMBINED.pdf

Extracted from the file · 11 pages · 23,418 characters

Text of EOE Set 2_COMBINED.pdf

Extracted from the file · 22 pages · 42,455 characters

Text of EOE Set 1_COMBINED.pdf

Extracted from the file · 200 pages · 332,382 characters

Text of EOE Set 4_COMBINED.pdf

Extracted from the file · 70 pages · 139,575 characters

Text of ICC Set 1_COMBINED.pdf

Extracted from the file · 30 pages · 51,093 characters

Text of OCC Set 13_COMBINED.pdf

Extracted from the file · 30 pages · 61,971 characters

Text of OCC Set 12_COMBINED.pdf

Extracted from the file · 73 pages · 193,636 characters

Text of OCC Set 11_COMBINED.pdf

Extracted from the file · 48 pages · 62,469 characters

Text of OCC Set 10_COMBINED.pdf

Extracted from the file · 51 pages · 90,368 characters

Text of OCC Set 5_COMBINED.pdf

Extracted from the file · 46 pages · 88,105 characters

Text of OCC Set 4_COMBINED.pdf

Extracted from the file · 159 pages · 268,038 characters

Text of OCC Set 3_COMBINED.pdf

Extracted from the file · 93 pages · 113,517 characters

Text of OCC Set 2_COMBINED.pdf

Extracted from the file · 68 pages · 113,929 characters

Text of OCC Set 1_COMBINED.pdf

Extracted from the file · 139 pages · 225,320 characters

  1. Page 27 of 66

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set OCC-14 Date Issued September 08, 2026 OCC-568 Page 1 of 2 Date Filed: September 22, 2026 Witness: David L. Gladey, Lavelle Freeman, John P. Dipaola-Tromba, Jennifer A. Schilling and Elli Ntakou Request from: Office of Consumer Counsel Question: In Exhibit CLP-TSP-3, Page 42, Eversource provides a table with investment categories by year. Please clarify how the following categories are mutually exclusive: a. b. c. d. Reliability Capacity Emergent Asset Health Response: Projects and programs shown in Exhibit CLP-TSP-3, at 42, are placed into a category by the main driver for the scope of work, although the project and/or programs may resolve multiple system concerns. For example the identified need to begin project or program development could be identified as capacity, however, a secondary driver could be asset health. In this instance the investment would be placed in the capacity category corresponding to the main driver of the work, although it resolves multiple system concerns such as asset health. The project and program investments in each of the categories are only accounted for in that category and are not included in additional categories. Exhibit CLP-TSP-3, pages 45 through 95 give additional information to describe the categories noted. a. Reliability projects are work on the system associated with improving or maintaining SAIDI and SAIFI metrics. Projects in this category could also include double pole removals and the smart switch program. b. Capacity projects are created to prevent equipment damage due to thermal overloads which could result in customer outages, while also providing operational flexibility to enable outages to be isolated and restored through alternate sources based on Eversource design criteria. They address peak load and capacity needs across the distribution system. c. Emergent project work includes items identified through routine inspections and maintenance as well as emergent/emergency equipment replacements in a substation or on the overhead and underground distribution system.
  2. Page 28 of 66

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set OCC-14 Date Issued September 08, 2026 OCC-568 Page 2 of 2 d. Asset Health includes the replacement of aging or obsolete equipment that has reached the end of its useful life in order to maintain safe and reliable system performance. Within this scope, key asset types include transformers, switchgear, poles, PILC, conductor, cables, breakers, batteries, reclosers, station service transformers, protective relays, gas monitors, and switches for example. The need for replacement is determined based on inspections, testing, equipment age, safety considerations, operating performance, changes in standards, equipment obsolescence, and spare parts availability.
  3. Page 29 of 66

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set OCC-14 Date Issued September 08, 2026 OCC-569 Page 1 of 3 Date Filed: September 22, 2026 Witness: David L. Gladey, Lavelle Freeman, John P. Dipaola-Tromba, Jennifer A. Schilling and Elli Ntakou Request from: Office of Consumer Counsel Question: In Exhibit CLP-TSP-3, Page 48, Eversource provides a table with investment categories by year. For each line item in the table, please provide a brief description of what investments are included in the line item, as well as how the line item is mutually exclusive from the other rows in the table. Response: Page 48 of Exhibit CLP-TSP-3 gives the general project and program categories to give insights into the Distribution Substation Capital Plan portion of the Targeted System Performance Plan. Projects and programs are placed into a category by the main driver for the scope of work. The identified need to begin project or program development could be identified as capacity and a secondary driver could be asset health. The investment would be placed in the capacity category with that being the main driver of the work although it resolves multiple system concerns. The project and program investments in each of the categories are only accounted for in that category and are not included in additional categories. Aging Infrastructure Replacements: This investment category includes projects and programs that support the replacement of aging or obsolete substation equipment that has reached the end of its useful life in order to maintain safe and reliable system performance. At substations, distribution assets include a range of equipment, depending on the type of station, and can include circuit breakers, bus work, relays, reactors, capacitors, switches, termination structures, control enclosures, protection and control equipment, power supply systems, physical and cyber security assets, cables and connecters, duct bank and cable trench, etc. The need for replacement is determined based on inspections, testing, equipment age, safety considerations, operating performance, changes in standards, equipment obsolescence, and spare parts availability. Inspection/Replacement Failed Equipment: This investment category is similar to Aging Infrastructure Replacements but differs in that it includes equipment replacements that can be completed under the annual funding policies and within a shorter time period than a typical project. Substation Transformer Asset Health: This investment category of projects includes replacement of the distribution substation transformer fleet. These units consist of Bulk transformers and Distribution transformers. Bulk transformers are installed at bulk distribution
  4. Page 30 of 66

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set OCC-14 Date Issued September 08, 2026 OCC-569 Page 2 of 3 substations that are directly supplied from the transmission system (typically 115 kV) and step voltage down to distribution levels (typically 23 kV, 13.2 kV, or 4.8 kV). Distribution transformers are installed at distribution substations supplied by other distribution systems (e.g., 23 kV) and step voltages down to supply customers. There are 314 transformers currently installed across CT distribution system. The present fleet average age is 43 years old with the oldest transformer inservice at 85 years old. Based on age records of distribution substation transformers, a portion of the fleet, about 56% have exceeded the 40-year expected service life of a transformer. This means that without repair or replacement, as each transformer ages, their condition is expected to continue declining, increasing the risk of equipment failure. As a result, Eversource continues to prioritize and initiate replacement projects for these transformers within this category of investments. Substation Transformer DSCADA LTC Controls: This investment category was established to track the installation of DSCADA Load Tap Changer (LTC) Automation at all remaining Eversource CT sites currently utilizing the obsolete radio-controlled system for substation LTC voltage reduction. The existing 1970's radio-controlled systems installed on Eversource transformers were obsolete and failing. Replacement radio units are not available as the system components are no longer supported by the manufacturer. The existing radio-controlled system could no longer support the required voltage reduction capability. Switchgear Asset Health: This investment category includes projects including the replacement of substation switchgear units that have aging equipment and deteriorating foundation conditions. These projects are needed to address concerns about long-term reliability, safety, and the ability of the equipment to continue operating as intended. Switchgear condition indicators typically include, but are not limited to, asset age, environmental impacts, short circuit margin, operational integrity (operating location in substation and frequency of operation), general model obsolescence (ability to obtain trained service personnel and replacement parts), and field assessment data (maintenance notifications/issues for breaker components like bushings, mechanism, contacts, and dielectric media). In many cases, the condition of the switchgear itself, combined with structural issues affecting its foundation, increases the risk of equipment failure or service interruptions. Replacing this equipment helps ensure the electric system remains dependable and supports safe operation for utility personnel. These investments also help to maintain service reliability and prepare the electric distribution system to meet future operational needs. Capital Tool Purchases: This investment category includes capital tool purchases to support the field personnel working in electrical substations. Capital tool purchases must meet the capitalization threshold requirement of $500 per unit cost. Exceptions to this $500 threshold include items which are purchased “in bulk” as defined in APS-08 Capital Versus Expense Criteria. Emergent Equipment Failures/Replacements: This investment category is similar to Aging Infrastructure Replacements but differs in that it includes emergent equipment failure replacements
  5. Page 31 of 66

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set OCC-14 Date Issued September 08, 2026 OCC-569 Page 3 of 3 that can be completed under the annual funding policies and within a shorter time period than a typical project. Environmental Equipment Replacements: This investment category includes projects to specifically replace aging oil filled substation equipment such as oil filled circuit breakers and oil filled substation reclosers. If a circuit breaker or recloser does not operate properly, the consequences can include serious safety risks for workers, reduced system reliability, environmental impacts such as oil leaks or spills, and damage to nearby equipment. In the case of a circuit breaker failure, failure to interrupt a fault, or experiences internal failure, the next available circuit breaker must operate. Depending on the design of the substation where the circuit breaker is installed, the severity of its unavailability will vary. When a recloser does not work properly, it can prevent automated systems from responding to problems leading to increased Customer Average Interruption Duration Index (CAIDI) and System Average Interruption Duration Index (SAIDI) minutes. A failed circuit breaker or recloser can also affect planned work, including efforts to safely isolate or restore power to lines and substations. Substation Capacity/System Planning: This investment category includes projects to address normal and emergency substation overloads within the 10-year planning horizon and those created to resolve violations of the Distribution System Planning Guide (DSPG). 1 Solution alternatives are developed with varying levels of complexity and may include a combination of balancing loading across the system, replacing or upgrading limiting equipment, adding new equipment or expanding an existing substation, installing non-wires alternatives, and/or developing a new substation to support the identified needs of the area. Incremental Aging Infrastructure Replacements: This investment category is the incremental funding required to replace additional aging substation equipment beyond what is included in the Sustained Performance Plan to achieve the Targeted System Performance Plan investment. Incremental Substation Transformer Asset Health: This investment category is the incremental funding required to replace additional aging substation transformers beyond what is included in the Sustained Performance Plan to achieve the Targeted System Performance Plan investment. 1 Refer to CLF-SC-023, Attachment 1, for the Eversource Distribution System Planning Guide 2020 Rev. 0.
  6. Page 32 of 66

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set OCC-14 Date Issued September 08, 2026 OCC-570 Page 1 of 2 Date Filed: September 22, 2026 Witness: David L. Gladey, Lavelle Freeman, John P. Dipaola-Tromba, Jennifer A. Schilling and Elli Ntakou Request from: Office of Consumer Counsel Question: In Exhibit CLP-TSP-3, Pages 40, 46, and 50 Eversource lists forecasted impacts to the system by spending scenario. For each listed impact on slides 40, 46, and 50, please share how Eversource plans to measure and monitor the impact over the 5-year spending period? Response: For reliability performance, the Company will measure and monitor reliability performance using standard and emerging reliability metrics, like SAIDI, SAIFI, CEMI and CELID. These metrics can be calculated with multiple different methodologies; for example, there is a CT-specific calculation for blue-sky SAIDI and SAIFI based on a certain method of delineating major storms. Eversource’s Outage Management System retains all interruption records, with the impacts to these metrics; Customers Impacted and Customer Minutes of Interruption per event. These metrics that measure and monitor reliability performance will be compared to the targets for PBR. For example, SAIDI and SAIFI will be compared to the 2022-2026 historical average plus one standard deviation. Accelerated investments in asset health (replacement of bare overhead Cu conductor, right-of-way rebuilds, and underground paper-in-lead-cable replacement), smart switches and resiliency combined with The Company’s core investment to mitigate SAIDI and SAIFI will drive improvements in reliability for both blue sky and storm performance. For resilience, the Company will monitor performance during major storms, measuring using metrics like all-in SAIDI and number of events. Importantly, major storm performance is a multiinput function where Company actions as well as exogenous factors drive system performance. Other aspects of TSP are also intended to improve storm performance and may be difficult to delineate the impacts of those to resilience metrics. For example, the Company’s proposed routing optimization for storm crews and for its outage prediction models critically impact storm performance. It is important to note that as performance improves, the threshold for major storms becomes higher (i.e., less storms will qualify as major storms), so a normalization to account for the sliding threshold may be required to baseline and compare performance. For distribution automation, the Company will estimate performance benefits of reclosing devices by assuming that each momentary event on these devices would have been a sustained interruption if the protective device was not capable of reclosing automatically. For example, in CLP-TSP-2 p.
  7. Page 33 of 66

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set OCC-14 Date Issued September 08, 2026 OCC-570 Page 2 of 2 30, it is estimated that 1.1M customers were spared from experiencing a sustained interruption in 2025 due to reclosers. Exhibit CLP-TSP-3, Page 46 provides information describing the different investment levels and their general impact to the distribution substation project portfolio. The projects within the Targeted System Performance Plan will be budgeted and monitored throughout their life cycle. The projects initiated will be reviewed against the initiatives noted and tracked through the project approval processes through to completion. Additionally, the transformer average fleet age and oldest age objectives will be tracked periodically to confirm the projects created and completed are moving us toward the set goals.
  8. Page 34 of 66

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set OCC-14 Date Issued September 08, 2026 OCC-571 Page 1 of 2 Date Filed: September 22, 2026 Witness: Douglas P. Horton Request from: Office of Consumer Counsel Question: In Exhibit CLP-AMI-1, Page 27, Eversource “proposes to include AMI capital costs as eligible capital costs to be recovered and reconciled in the proposed PBMRP capital funding mechanism.” However, it proposes to recover incremental O&M costs and legacy meter infrastructure costs using securitization. Please explain why AMI capital costs should not also be recovered using securitization. Response: Please refer to OCC-571, Attachment 1 and OCC-571, Attachment 2, for a comprehensive discussion on the benefits, costs and appropriate use of securitization as a financing instrument for utility costs. Attachment 1 is a report prepared by Atrium Economics that was jointly sponsored by the Company’s Massachusetts operating affiliates and other Massachusetts LDCs. The report was prepared for the purpose of explaining why securitization financing is not an appropriate or viable financing vehicle for ongoing utility investments. Attachment 2 is a legal memorandum prepared by the Company in relation to draft legislation in Massachusetts contemplating the securitization of electric-system upgrades to support electrification and grid-modernization assets. Both reports explain the reasons that securitization is generally not appropriate when costs are ongoing, operational, or “business-as-usual.” Examples include routine capital investments, annual maintenance, or safety-related replacements that occur every year, which would encompass the new metering system and associated back-office information systems that will constitute Advanced Metering Infrastructure on the Company’s system in Connecticut. Outside of certain extraordinary circumstances, operating utility assets cannot be securitized. As explained most directly in Attachment 2, securitization requires establishment of a bankruptcyremote special purpose entity (an “SPE”) that acquires the right to impose and collection the rate reduction bond charge from the related utility through a true sale and then issues bonds secured by a first-priority lien on that right. An investor-owned utility cannot transfer physical assets to a securitization SPE because those assets require continuous capital investment that a passive, limited-purpose entity cannot fund. Instead, securitization is a solution that involves an intangible cash flow right that requires no maintenance or reinvestment, such as in the circumstances of storm
  9. Page 35 of 66

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set OCC-14 Date Issued September 08, 2026 OCC-571 Page 2 of 2 restoration costs, stranded meter costs, stranded generating assets or other costs that are essentially one-time costs that constitute a debt owed by customers to the utility with no ongoing maintenance, repair or investment required or applicable. The primary barrier to the securitization of utility operating assets is the capital maintenance problem. Physical utility infrastructure requires continuous capital investment to maintain operational capability and regulatory compliance. A securitization SPE cannot fund such capital because it cannot raise equity, issue additional debt, borrow, retain earnings, or contract for maintenance work. Physical assets placed in an SPE would inevitably deteriorate and Moody’s has specifically identified asset deterioration as a critical credit risk for utility systems. However, transferring assets to an SPE that are required for a utility to operate would prevent the utility from providing service using assets it controls. Moreover, even if physical assets were placed in the SPE, the SPE would not obtain the AAA credit rating that makes it possible to achieve the beneficial cost for customers. Attachment 1 explains other impacts that would occur for the utility’s cost of capital in the event that this type of financing would apply for utility assets. The transfer to an SPE of the intangible property to the rate reduction bond charge right works in relation to large deferred expenses that a utility may have, such as storm costs or the costs of “stranded” assets, no longer used and useful for utility ratepayers because these types of “assets” do not depreciate, require no maintenance or capital and can be cleanly transferred through a true sale, thereby allowing the SPE to remain purely passive—all while the utility retains and continues to operate its physical system. For AMI, this means that securitization is a possibility for the relatively significant one-time operating expenses that must be incurred to implement AMI across the State of Connecticut, as well as the costs of stranded meter investment. For the remainder of the cost that comes in the form of capital investment, it will not be possible to use securitization as the funding mechanism for that portion of the cost.
  10. Page 36 of 66

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set OCC-14 Date Issued September 08, 2026 OOC-572 Page 1 of 2 Date Filed: September 22, 2026 Witness: Douglas P. Horton and Jared A. Lawrence Request from: Office of Consumer Counsel Question: In Exhibit CLP-AMI-2, Page 87, Eversource states that "Recognizing that the AMI program requires sizable investments, Eversource embraces accountability for executing the program effectively and delivering the expected benefits to customers. Accordingly, Eversource proposes a performance metrics framework to provide transparency into both the success of the AMI deployment and the realization of benefits. In each category, the Company is proposing to report annually on a slate of metrics.” a. Given Eversource’s stated commitment to accountability, please explain what would happen if the company does not achieve the expected performance metrics in the proposed time horizon. Response: As an initial matter, Eversource is fully committed to accountability and expects to have performance metrics that apply to the AMI implementation once it is clear that the AMI implementation plan will move forward and on what terms. In the event that PURA approves the AMI implementation plan on reasonable terms that the Company can work with, then it would be appropriate to structure a performance mechanism around a subset of the scorecard metrics described in pages 87-89 of the Company’s AMI Plan. In particular, the scorecard referenced on page 87 of the AMI Plan will provide transparency for the Company, PURA and other stakeholders to determine what stage the program has reached in relation to expected value; where alternative sources of value may be occurring; and whether program changes need to be made in response to changing conditions. In addition, the Company is interested in exploring a symmetrical incentive/penalty mechanism that would incorporate project milestones and operational success components. The AMI deployment success mechanism would be evaluated by PURA at the completion of the last program milestone included in the mechanism. Milestones to be included in the AMI Deployment Success mechanism could incorporate the following: • CIS Deployment • MDMS Deployment

As listed on the current system

Corres. 09/29/2026 [26-05-10] (Keegan Werlin LLP) - Compilations of discovery responses

This filing on the current system (opens in a new tab)