    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set OCC-17 Date Issued September 11, 2026 OCC-732 Page 1 of 1 Date Filed: September 28, 2026 Witness: Amparo Nieto Request from: Office of Consumer Counsel Question: (ACOSS) Refer to Exh. CLP-ACOS-1. Does the Company have the data needed to calculate customer-related unit costs separately for multi-family and single-family customers? If so, please provide the data and calculation in a live, unlocked Excel format with all formulas intact, including a breakdown of the costs by FERC account. If not, please specify what additional data would be necessary to perform the calculation. Response: The Company does not have the data to separately calculate customer-related unit costs for single vs multi-family customers.
  2. Page 32 of 45

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set OCC-17 Date Issued September 11, 2026 OCC-733 Page 1 of 2 Date Filed: September 28, 2026 Witness: Amparo Nieto Request from: Office of Consumer Counsel Question: (MCOSS) Refer to Exh. CLP-MCOS-1, at 17-18. In a live, unlocked Excel format with all links and formulas intact, please provide the Company’s probability of peak analysis and all underlying workpapers and data. Response: The Company’s probability of peak analysis was performed with Python and therefore a workpaper is not available for computation of the probability of peak (PoP) analysis. However, the input data used in the Python code is included in OCC-733, Attachment 1. Additionally, an explanation of the main steps followed in calculating the PoP in Python is provided below. 1. The sum of historical hourly Substation Loads from January 2022, to December 2025 across all the distribution substations provided by the Company were grouped by hour type, where each hour defined by month, hour beginning, and weekday vs. weekend/holiday. 2. For each historical year, each hourly load was divided by the average hourly load in that same year. This allows filtering out year-to-year customer growth impacts on load for comparable analyses across years. A delimiter based on the average of the four historical year ratios (for 2022-2025) of the maximum hourly load in the year to the same year’s average hourly load was calculated. This ratio is used later in the analysis to determine a simulated hour’s weight in the PoP calculation. 3. For each hour by day type and month, a Kernel Density Estimation was used to create representative distributions of future gross hourly distribution substation loads, which back into the PV impacts. In particular, the model simulated hourly load distributions 500 times using a truncated version of Gaussian Kernel density estimation (KDE). KDE with a gaussian kernel is a non-parametric method that forms a small probability density function (PDF). The final distribution for a given hour is obtained from adding the sum of these point-based PDFs. 4. To factor in the expected impact of BTM PV generation on near-term load profiles, the analysis considers the cumulative forecasted additions of BTM PV capacity in
  3. Page 33 of 45

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set OCC-17 Date Issued September 11, 2026 OCC-733 Page 2 of 2 Eversource’s CT service area (based on ISO-NE projections through the mid-point of the period 2026 through 2031). Capacity factors from NREL’s National Solar Radiation Database (NSRD) are then applied to annual BTM PV capacity forecasts to yield hourly PV generation projections. The hourly PV data for each hour type is then subtracted from the simulated hourly gross loads to yield hourly distribution net loads. 5. For a given hour and day type, any hour in the simulation with a load > delimeter calculated in step 2 is given a weight of 1 for PoP; other hours are given a weight of zero. The percent of hours of a given type with loads at or above the delimiter across the simulations provides a vector of hourly probabilities for each month. These hourly probabilities are divided by the sum of the probabilities across all hours such that they add up to 1. The resulting PoPs are stated by hour, day type and month.
  4. Page 34 of 45

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set OCC-17 Date Issued September 11, 2026 OCC-734 Page 1 of 1 Date Filed: September 28, 2026 Witness: Edward A. Davis and Kimberly R. Parsons Request from: Office of Consumer Counsel Question: (Residential Customer Charge) Refer to Exh. CLP-RATES-2.13, and Exhibit CLP-RATES-1, at 17, which states “The Company completed the MRCC calculation, as provided in Exhibit CLPRATES-2 2.13. This calculation produced a customer charge of $12.36 for Rate 1.” Please explain why the value of $12.36 differs from the value of $11.09, as shown in row 65 of tab “Exh 2.13, 1 of 19.” Response: Please refer to OCC-735, Attachment 1, for an updated version of the MRCC Exhibit shown in CLP-RATES-2.13. In preparing this response, the Company discovered that when formatting the original document for filing purposes, one of the inputs to the calculation shown on page 12 of 19 was inadvertently deleted. The full corrected detail of the calculation of Current Income Tax is provided in OCC735, Attachment 1, where the calculation begins on Line 18, with Total Gross Plant in Service in the amount of $577,005.
  5. Page 35 of 45

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set OCC-17 Date Issued September 11, 2026 OCC-735 Page 1 of 1 Date Filed: September 28, 2026 Witness: Edward A. Davis and Kimberly R. Parsons Request from: Office of Consumer Counsel Question: (Residential Customer Charge) Refer to Exh. CLP-RATES-2.13, tab “Exh 2.13, 12 of 19” row 44. Refer also to Exh. CLP-RATES-2.13, tab “Exh 2.13, 1 of 19” row 65. Please explain why the total values on these rows differ. Response: The two values cited should be the same. In preparing the response to this data request, the Company identified three corrections that need to be made in the MRCC Exhibit shown in CLPRATES-2.13: 1. In preparing this response, the Company discovered that when formatting the original document for filing purposes, one of the inputs to the Current Income Tax calculation shown on Page 12 of 19 was inadvertently deleted. The calculation should begin on Line 18 with Total Gross Plant in Service in the amount of $577,005. The omission of this figure reduced the following figures now shown on Page 1 of 19: Current Income Taxes (Line 61), Gross Receipts Tax (Line 62), Total Taxes (Line 64) and the total MRCC (Line 66). 2. The Total Accumulated Depreciation shown on Page 12 of 19 should have been a negative value in the calculation. This change reduces the Total Rate Base. 3. Page 1 of 19 omitted Account 935 in the amount of $4,000. The impact to the MRCC charge is small ($0.00031 per month), however, for the revenue requirement shown on Page 1 to match the revenue requirement shown on Page 12, it must be included. The result of the changes detailed above reduces the calculated MRCC to $11.62 per month from the $12.36 per month figure shown in the Company’s initial filing. Please refer to OCC-735, Attachment 1, for an updated version of the MRCC Exhibit shown in CLP-RATES-2.13.
  6. Page 36 of 45

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set OCC-17 Date Issued September 11, 2026 OCC-736 Page 1 of 2 Date Filed: September 28, 2026 Witness: Edward A. Davis and Kimberly R. Parsons Request from: Office of Consumer Counsel Question: (Residential Customer Charge) Refer to PURA’s December 20, 2017 Decision in Docket No. 1701-12, page 35, which states that the “Authority will operate on the rebuttable presumption that costs in Accounts 920, 921, and 923 are excluded from the MRCC calculation,” and defines specific requirements that EDCs must satisfy in order to include these costs in the MRCC calculation. Please provide the justification for inclusion of these costs, including supporting documentation and workpapers. Response: Please refer to PURA’s April 18, 2018 Decision in Docket No. 17-10-46, page 33, where PURA determined that Eversource was allowed to include a portion of Accounts 920, 921 and 923 in its MRCC calculation: The Authority recognizes that Eversource is structured in such a way that certain labor is performed and expenses are incurred by the Service Company and then shared among the Eversource Companies including CL&P. The Company provided sufficient documentation that costs attributed to FERC Accounts 920, 921, 923 and 930 are directly related to the statutory functions and are thereby includable in the MRCC calculation. The Company also stated that it is part of the Eversource family of companies (Service Company) and relies on the Service Company for a certain amount of labor and expenses that directly support the Statutory Functions. Supplemental TRP Testimony, pp. 7 and 8. In the Supplemental TRP Testimony, the Company wrote: Q. What is the rationale for including the A&G FERC Accounts in the calculation of MRCC? A. As described during hearings in Docket No. 17-01-12, the labor for many employees who work to support at least one of the four MRCC functions for the Service Company (as opposed to the Company directly), is recorded to FERC Account 920. It is vital to capture these costs since they represent real and significant cost responsibility to the Company for labor that is incurred to support includable functions. The exclusion of these costs not
  7. Page 37 of 45

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set OCC-17 Date Issued September 11, 2026 OCC-736 Page 2 of 2 only contradicts the Statute but is also inconsistent with the Decision. As described in discovery responses and direct testimony in Docket 17-01-12, because the Company is part of the Eversource family of companies and relies on the Service Company for a certain amount of labor and expenses that directly support the Statutory defined functions, they should be included in the MRCC calculation. Many of these costs, however, are allocated to CL&P through Service Company charges to Account 920. In fact, the existence of the Service Company configuration allows Eversource to provide the benefits of economies of scale to ratepayers such that the allocated costs to ratepayers is lower than what otherwise would be incurred and allocated on a stand-alone Company basis. It would be inconsistent with the Statute for the Authority to exclude these costs because they arise from the Service Company configuration and in fact, that structure provides great benefit to ratepayers. The Company also believes that since the Office Supplies Expense (FERC Account 921), is allocated to the customer component based on Overhead, it should also be included in the MRCC since Overhead is a direct assigned component based on includable CCCs. For Outside Services expense, the Company utilized the Distribution Plant allocator which is the same methodology used to allocate costs in the Test Year COSS, however, it was updated to only reflect includable MRCC plant. The Company applied the methodology approved in the Company’s last case when preparing the MRCC calculation shown in Exhibit CLP-RATES-2.13.
  8. Page 38 of 45

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set OCC-17 Date Issued September 11, 2026 OCC-737 Page 1 of 2 Date Filed: September 28, 2026 Witness: Edward A. Davis and Kimberly R. Parsons Request from: Office of Consumer Counsel Question: (Residential Customer Charge) Refer to PURA’s December 20, 2017, Decision in Docket No. 1701-12, pages 35-36, which states that “The Authority finds that costs in Accounts 922, 928, 930, and 931 are outside of the statutory functions and are excluded from the MRCC calculation.” Please explain why the Company has included costs in Account 930 in the calculation of the MRCC. Response: Please refer to PURA’s April 18, 2018, Decision in Docket No. 17-10-46, page 33, where PURA determined that Eversource was allowed to include a portion of Account 930 in its MRCC calculation: The Authority recognizes that Eversource is structured in such a way that certain labor is performed and expenses are incurred by the Service Company and then shared among the Eversource Companies including CL&P. The Company provided sufficient documentation that costs attributed to FERC Accounts 920, 921, 923 and 930 are directly related to the statutory functions and are thereby includable in the MRCC calculation. The Company also stated that it is part of the Eversource family of companies (Service Company) and relies on the Service Company for a certain amount of labor and expenses that directly support the Statutory Functions. Supplemental TRP Testimony, pp. 7 and 8. In the Supplemental TRP Testimony, the Company wrote: Q. What is the rationale for including the A&G FERC Accounts in the calculation of MRCC? A. As described during hearings in Docket No. 17-01-12, the labor for many employees who work to support at least one of the four MRCC functions for the Service Company (as opposed to the Company directly), is recorded to FERC Account 920. It is vital to capture these costs since they represent real and significant cost responsibility to the Company for labor that is
  9. Page 39 of 45

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set OCC-17 Date Issued September 11, 2026 OCC-737 Page 2 of 2 incurred to support includable functions. The exclusion of these costs not only contradicts the Statute but is also inconsistent with the Decision. As described in discovery responses and direct testimony in Docket 17-01-12, because the Company is part of the Eversource family of companies and relies on the Service Company for a certain amount of labor and expenses that directly support the Statutory defined functions, they should be included in the MRCC calculation. Many of these costs, however, are allocated to CL&P through Service Company charges to Account 920. In fact, the existence of the Service Company configuration allows Eversource to provide the benefits of economies of scale to ratepayers such that the allocated costs to ratepayers is lower than what otherwise would be incurred and allocated on a stand-alone Company basis. It would be inconsistent with the Statute for the Authority to exclude these costs because they arise from the Service Company configuration and in fact, that structure provides great benefit to ratepayers. […] The last A&G FERC Account the Company included in the MRCC is the Misc. General Expense (Account 930). Although PURA identified this account as excluded from the calculation, the Company still believes that because the Overhead allocator used (which is based on directly assigned labor) the expense using that allocator should be included in the MRCC calculation. The Company applied the methodology approved in the Company’s last case when preparing the MRCC calculation shown in Exhibit CLP-RATES-2.13.
  10. Page 40 of 45

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set OCC-17 Date Issued September 11, 2026 OCC-738 Page 1 of 2 Date Filed: September 28, 2026 Witness: Amparo Nieto Request from: Office of Consumer Counsel Question: (ACOSS) Refer to Exh. CLP-ACOS-1 regarding the minimum distribution study. Refer also to PURA’s October 28, 2025, Decision in Docket No. 24-10-04, pages 198-199, which states in part that “the minimum system’s load-carrying capacity should be considered when allocating residual demand-related costs.” a. Please explain whether the Company considered the minimum system’s load carrying capacity when allocating demand-related costs. If yes, please provide the workpapers, including assumptions, used for this calculation. b. Please provide the Rate Year load-carrying capacity adjustments in a similar format to Table 81 on page 199 of the Decision in Docket No. 24-10-04. Response: a. The Company did not adjust the Minimum System calculations to revise the demand classification percentage based on the minimum system carrying capability. The ACOS study relies on the traditionally applied MDS approach as applied in prior rate cases and as per the NARUC Manual. The minimum cost is treated as purely customer-related, expressed as a percentage of total asset costs and allocated to all customer classes in the ACOSS on the basis of total customer numbers in the class. While the Company recognizes that each minimum sized asset has some level of load carrying capacity, the adjustment of demand allocations based on unrealized demand would effectively skew the allocation results towards the commercial and industrial classes. These classes use transformers with larger economies of scale and therefore have a lower per kVA cost relative to the smaller transformers. The load carrying capacity method, as ordered in the UI rate case decision, essentially is prone to shift costs to customer classes with lower customer numbers but also with a lower per-kW of transformer capacity because it assumes that the same per-kVA cost applies to every kW of NCP across the board. If the objective of the proposed refinement to the MDS is to more precisely allocate the cost of FERC accounts 365-368 local facilities by customer class, to take into account specific tradeoffs between the cost drivers of investment for each customer classes, a superior approach would be to rely on the results of the marginal cost study as per the class