Discovery Compilation (0CC Set 16).
Filed by Keegan Werlin LLP2 files
Part of docket 26-05-10Files2
Docket No. 26-05-10 Discovery Compilation October 1 2026.pdf
PDF · 154 KB · 1 pageText searchable
Download Docket No. 26-05-10 Discovery Compilation October 1 2026.pdfRead the text of Docket No. 26-05-10 Discovery Compilation October 1 2026.pdf
OCC Set 16_COMBINED.pdf
PDF · 1.2 MB · 148 pagesText searchable
Download OCC Set 16_COMBINED.pdfRead the text of OCC Set 16_COMBINED.pdf
Search terms highlighted
Eversource rate increase is on 13 pages of the text below, highlighted. Go to the first matchClear highlighting
Page 7 of 148
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set OCC-16 Date Issued September 10, 2026 OCC-608 Page 1 of 1 Date Filed: September 24, 2026 Witness: Jared A. Lawrence and Shamus O’Brien Request from: Office of Consumer Counsel Question: (CUSTOMER SERVICE) What pre-pandemic trends in customer perceptions of Eversource has the Company identified? Have there been significant shifts since the onset of the COVID-19 pandemic? Response: Satisfaction trends related to the onset of the COVID-19 pandemic were subsumed early by the impacts of the July 2020 significant increases in energy usage and the accompanying rate increases, and the impacts from Tropical Storm Isaias in August 2020. Customer responses to these events were so significant that it is not feasible to point to satisfaction trends post-pandemic that were isolated to the pandemic itself. However, it can be noted that in the few months between the onset of the pandemic and the events listed above, there was an increase in satisfaction year-over-year compared to the same period in 2019. Among Connecticut electric customers, satisfaction showed a 3.4% increase in the March 2020 to June 2020 period compared to the same time period in 2019.Page 8 of 148
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set OCC-16 Date Issued September 10, 2026 OCC-609 Page 1 of 1 Date Filed: September 24, 2026 Witness: Brendan J. O’Brien, Garrett J. Murray and Christopher Leigh Request from: Office of Consumer Counsel Question: (CYBERSECURITY COSTS) In an unlocked Excel spreadsheet, please identify all costs included in the Test Yar associated with cybersecurity measures, noting the filing/line in which that cost is contained and explaining the work associated with that cost. Response: Please refer to the table below for the cyber security costs included in the Test Year and related description for services provided. These costs are contained within Exhibit CLP-REVREQ-2, WP C-3.8 Line 23 in the Security category and equate to $1.6M of the total $2.0M shown. Vendor Name ALLEGIS GLOBALSOLUTIONS INC Description Overall contractor support within IT Cyber Security Vendor support and maintenance ATLANTIC DATASECURITYLLC related to products (Checkpoint, NetScout), firewalls, etc DRAGOS INC Product maintenance for Rapid Response product. Overall product software maintenance GUIDEPOINT SECURITY for a wide variety of products that includes Crowdstrike, Guardicore, Proofpoint, Tenable, Zscaler, etc. IDEFENDER LLC Product maintenance for Industrial Defender software. Vendor security engineering support for LTIMINDTREE LIMITED overall IT Cyber Security initiatives. TEKSYSTEMS GLOBALSERVICES LLC Vendor security architecture support for overall IT Cyber Security initiatives. Total IT Cyber Security Costs Test Year $64,208 $404,232 $24,079 $929,381 $56,680 $112,006 $26,832 $1,617,418Page 9 of 148
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set OCC-16 Date Issued September 10, 2026 OCC-610 Page 1 of 1 Date Filed: September 25, 2026 Witness: Douglas P. Horton, Sasha P. Lazor and Marianne H. Eichler Request from: Office of Consumer Counsel Question: (VARIABLE PAY) Please refer to EMPLOYEE-CLP-1, Table 8. The “Strategic Financial Incentives and Regulatory Outcomes” are “Regulatory filings, storm cost recovery and strategic positioning.” a. Please explain all specific regulatory filings that factored into this metric; b. Please confirm if “storm cost recovery” referred to Docket No. 25-12-13 and, if so, explain how this was measured to have been met; c. Please explain “strategic positioning” and indicate how this was measured to have been met. Response: a. Please refer to OCC-610, Attachment 1, pages 56-57, for a detailed overview of the factors of this metric. b. Please refer to OCC-610, Attachment 1, page 56, for a detailed overview of storm cost recovery. c. Strategic positioning refers to initiatives that are intended to improve the ways in which the Company operates. For example, in OCC-610, Attachment 1, page 57, “Improve corporate-wide cost structure and financial condition” is described as a goal. This goal was measured to have been met through “resulting in lower cost supply operation while sustaining optimal performance.” This type of performance better positions the Company in the current and subsequent years.Page 10 of 148
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set OCC-16 Date Issued September 10, 2026 OCC-611 Page 1 of 1 Date Filed: September 25, 2026 Witness: Sasha P. Lazor and Marianne H. Eichler Request from: Office of Consumer Counsel Question: (VARIABLE PAY) Please refer to EMPLOYEE-CLP-1, Table 8 and the Response to OCC-198, Attachment 1. Each year from 2018 through 2023 had a separate table. Please explain if Table 8 reflects 2024 metrics or 2025 metrics and provide whichever year Table 8 does not reflect. Response: Employee-CLP-1, Table 8, is pulled from the Company’s 2026 Proxy Statement, which covers performance for 2025. 2024 Goals are included in OCC-611, Attachment 1.Page 11 of 148
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set OCC-16 Date Issued September 10, 2026 OCC-612 Page 1 of 1 Date Filed: September 29, 2026 Witness: Sasha P. Lazor and Marianne H. Eichler Request from: Office of Consumer Counsel Question: (VARIABLE PAY) Please refer to EMPLOYEE-CLP-1, Table 8 and the Response to OCC-196, which explains that Table 8 refers to Eversource-level goals. a. Please identify which goals included in Table 8’s “Key Strategic Financial and Regulatory Results” and “Key Strategic Customer and Clean Energy Operational Results” included results from Connecticut and explain how those goals were met. b. Please explain how Connecticut factored into the remaining Operational Performance goals in Table 8 (e.g., what was Connecticut’s average MBI, SAIDI, etc…). Response: a. Please refer to OCC-612, Attachment 1, pages 49-50, of the attached 2026 Proxy Statement for a description of Connecticut results in “Key Strategic Financial and Regulatory Results”. b. Connecticut Operational Performance Goals are as follows: Goal MBI CAIDI SAIDI Target 19.1 113.0 71.0 Result 20.1 129.6 77.6Page 12 of 148
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set OCC-16 Date Issued September 10, 2026 OCC-613 Page 1 of 1 Date Filed: September 24, 2026 Witness: Sasha P. Lazor and Marianne H. Eichler Request from: Office of Consumer Counsel Question: (VARIABLE PAY) Please refer to CLP-EMPLOYEE-3. a. Please confirm that every employee with a rating of “Improvement Needed to be a Successful Contributor” or higher received a variable pay award in the Test Year. b. Please confirm that every employee with a rating of “Improvement Needed to be a Successful Contributor” or higher received a merit raise in the Test Year. Response: a. Every employee with a rating of Successful Contributor or higher received a variable pay award in the Test Year, in accordance with the guidelines. The variable pay guidelines for “Improvement Needed to be a Successful Contributor” range from 0% to 70% of target and, in accordance with those guidelines, there were employees who did not receive a variable pay award. b. Every employee with a rating of Successful Contributor or higher whose salary was below the top of the salary range for their job received a merit raise in the Test Year, in accordance with the guidelines. Those employees with a rating of Successful Contributor whose salaries were at the top of the range received a lump-sum merit award, in accordance with the guidelines. The merit raise guidelines for “Improvement Needed to be a Successful Contributor” range from 0% to 2% and, in accordance with the guidelines, some employees did not receive a merit raise.Page 13 of 148
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set OCC-16 Date Issued September 10, 2026 OCC-614 Page 1 of 1 Date Filed: September 24, 2026 Witness: Marianne H. Eichler Request from: Office of Consumer Counsel Question: (VOLUNTARY SEPARATION) For each employee who voluntarily separated from the Company in 2025, please indicate the employee’s position and the stated reason for separation. Response: Please refer to OCC-614, Attachment 1.Page 14 of 148
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set OCC-16 Date Issued September 10, 2026 OCC-615 Page 1 of 3 Date Filed: September 24, 2026 Witness: David L. Gladey and Steven Lamontagne Request from: Office of Consumer Counsel Question: (POLES) Please refer to Exhibit CLP-TSP-1, p. 27, which states that many wood poles “do not meet current strength standards.” Please clarify: a. Of the total number of poles, what percentage are wood poles? b. What are the sources of the loads on the poles? c. To the extent some loads result from communications wires, has the Company studied the allocation of load attributable to each source (i.e., does the Company know the amount of load associated with each type of wire on the pole)? If so, please provide. d. Would the poles meet current strength standards if they contained only electric lines? Response: The following statement “do not meet current strength standards” is in reference to The Company’s current minimum pole class requirements when setting new poles. The statement does not refer to any pole testing performed under the pole integrity program. The original statement indicated distribution poles that did not meet the current minimum pole class standard. Since then, the Company has completed a deeper review of its asset records and identified that 37% distribution poles do not have a verified class rating in Company records and were identified as not meeting the Company’s current minimum pole class requirement. Please refer to the following breakdown: • • • 39% of distribution poles do not meet The Company’s current minimum pole class standard 37% of distribution poles do not have a verified class rating in our asset records 24% of distribution poles meet The Company’s current minimum pole class standard The Company’s pole integrity program is the basis for determining if poles no longer have sufficient strength to remain in-service. Please refer to the Company’s response to information request NECTA-016 i for the Company’s pole inspection process.Page 15 of 148
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set OCC-16 Date Issued September 10, 2026 OCC-615 Page 2 of 3 Prior Referenced Response: i NECTA-016 Question: (Pole Management & SPA) Refer to Exhibit CLP-ADDITIONS-1 at p. 64 (“Replacements are based on annual inspections”). Provide the following: a. b. Describe the Company’s annual inspection process, including the number of poles inspected each year, the data collected during the inspection, the criteria used to determine the integrity of the pole, who performs the inspections, and how the information collected during the inspections is used. Provide all data collected during the most recent annual inspection. NECTA-016 Response: a. The Company performs its routine and annual pole inspection to its custodial wooden poles following a 15year inspection cycle which ended in 2025. This cycle ensured that every custodial pole across 157 towns in Connecticut was inspected at least once within the time frame. Approximately 29,000 to 32,000 poles were inspected using the 15-year cycle. In 2025, the Company reviewed its wood-pole inspection standards and decided to shorten the inspection cycle from 15 years to 10 years. By adopting a more frequent inspection schedule, the Company aims to evaluate each custodial pole every 10 years, allowing issues to be identified earlier and addressing them more proactively. Under the revised 10-year cycle, approximately 41,000 to 42,500 poles will be inspected starting in 2026 and moving forward. The inspection process is based on the age of the pole. A visual inspection is completed for poles with less than 20 years of service. For poles with more than 20 years in service the inspection will include a visual, sound and bore, resistograph testing also known as IML testing, and the application of preservatives “treatment” required to maintain the structural integrity of the pole, and ensure continuous serviceability until the subsequent inspection interval. The number of poles replaced each year due to age, structural deterioration, damage, or end-of-life conditions varies based on the number of rejected poles identified through the annual pole inspection program. Poles classified as “Rejects” cannot remain in service because their remaining strength has fallen below 67% of their original strength or because they exhibit structural or mechanical damage that compromises safe operation. These poles are scheduled for replacement within one year of identification. Poles classified as “Priority Rejects” represent the most critical conditions and cannot remain in service because their remaining strength has fallen below 25% of their original strength and/or they exhibit severe structural or mechanical deterioration that presents an immediate public safety risk and reliability. Priority Reject poles are made safe within 48 hours of identification and are replaced as soon as practicable. Poles classified as “Leaning” are poles that are susceptible to failure and may pose risks to public safety and electric system reliability. Leaning poles occur when soil disturbances, loading from pole attachments, or other external forces alter the pole’s original alignment. These conditions are commonly caused by soil saturation and moisture accumulation, excessive structural loading, vehicle impacts, severe weather, or storm-related damage. Depending on the severity of the condition, findings from the pole inspection processPage 16 of 148
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set OCC-16 Date Issued September 10, 2026 OCC-615 Page 3 of 3 are communicated to the Company on a daily, weekly, or immediate basis to ensure appropriate corrective actions are taken. Currently, GeoForce Utility Technologies is the contractor responsible for performing all pole inspections throughout Connecticut during the 2024-2026 period. The selection of pole inspection contractors follows a competitive bidding process, with the successful bidder typically awarded a three-year inspection cycle contract. b. Please refer to NECTA-009i for the data collected during the most recent pole inspection.
As listed on the current system
Corres. 10/01/2026 [26-05-10] (Keegan Werlin LLP) - Discovery Compilation (0CC Set 16).