Compilation of Discovery Responses
Files15
Docket No. 26-05-10 Discovery Compilations October 21 2026.pdf
PDF · 157 KB · 2 pagesText searchable
Download Docket No. 26-05-10 Discovery Compilations October 21 2026.pdfRead the text of Docket No. 26-05-10 Discovery Compilations October 21 2026.pdf
ALLCO Set 7_COMBINED.pdf
PDF · 291 KB · 24 pagesText searchable
Download ALLCO Set 7_COMBINED.pdfRead the text of ALLCO Set 7_COMBINED.pdf
CIEC Set 5_COMBINED.pdf
PDF · 112 KB · 2 pagesText searchable
Download CIEC Set 5_COMBINED.pdfRead the text of CIEC Set 5_COMBINED.pdf
CLF-AC Set 2_COMBINED.pdf
PDF · 394 KB · 18 pagesText searchable
Download CLF-AC Set 2_COMBINED.pdfRead the text of CLF-AC Set 2_COMBINED.pdf
EOE Set 7_COMBINED.pdf
PDF · 1.4 MB · 150 pagesText searchable
Download EOE Set 7_COMBINED.pdfRead the text of EOE Set 7_COMBINED.pdf
NECTA Set 4_COMBINED.pdf
PDF · 409 KB · 14 pagesText searchable
Download NECTA Set 4_COMBINED.pdfRead the text of NECTA Set 4_COMBINED.pdf
NECTA Set 5_COMBINED.pdf
PDF · 533 KB · 27 pagesText searchable
Download NECTA Set 5_COMBINED.pdfRead the text of NECTA Set 5_COMBINED.pdf
OCC Set 22_COMBINED.pdf
PDF · 627 KB · 40 pagesText searchable
Download OCC Set 22_COMBINED.pdfRead the text of OCC Set 22_COMBINED.pdf
OCC Set 23_COMBINED.pdf
PDF · 257 KB · 8 pagesText searchable
Download OCC Set 23_COMBINED.pdfRead the text of OCC Set 23_COMBINED.pdf
OCC Set 25_COMBINED.pdf
PDF · 323 KB · 33 pagesText searchable
Download OCC Set 25_COMBINED.pdfRead the text of OCC Set 25_COMBINED.pdf
OCC Set 26_COMBINED.pdf
PDF · 240 KB · 11 pagesText searchable
Download OCC Set 26_COMBINED.pdfRead the text of OCC Set 26_COMBINED.pdf
PURA Set 6_COMBINED.pdf
PDF · 1.5 MB · 82 pagesText searchable
Download PURA Set 6_COMBINED.pdfRead the text of PURA Set 6_COMBINED.pdf
PURA Set 7_COMBINED.pdf
PDF · 1.4 MB · 141 pagesText searchable
Download PURA Set 7_COMBINED.pdfRead the text of PURA Set 7_COMBINED.pdf
UCONN Set 1_COMBINED.pdf
PDF · 597 KB · 45 pagesText searchable
Download UCONN Set 1_COMBINED.pdfRead the text of UCONN Set 1_COMBINED.pdf
UCONN Set 2_COMBINED.pdf
PDF · 372 KB · 19 pagesText searchable
Download UCONN Set 2_COMBINED.pdfRead the text of UCONN Set 2_COMBINED.pdf
Text of CLF-AC Set 2_COMBINED.pdf
Extracted from the file · 18 pages · 32,497 characters
Text of EOE Set 7_COMBINED.pdf
Extracted from the file · 150 pages · 432,851 characters
Text of NECTA Set 4_COMBINED.pdf
Extracted from the file · 14 pages · 26,843 characters
Text of NECTA Set 5_COMBINED.pdf
Extracted from the file · 27 pages · 51,321 characters
Text of OCC Set 22_COMBINED.pdf
Extracted from the file · 40 pages · 63,151 characters
Text of OCC Set 23_COMBINED.pdf
Extracted from the file · 8 pages · 12,023 characters
Page 8 of 33
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set OCC-25 Date Issued October 05, 2026 OCC-916 Page 1 of 1 Date Filed: October 19, 2026 Witness: Jared A. Lawrence and Timothy W. McGrath Request from: Office of Consumer Counsel Question: (ACCOUNT NUMBERS) If a customer pays into an incorrect account does the customer get a credit on the “correct” account once the error is discovered by the Company? Response: If a customer makes a payment to an incorrect billing account, the Company requires the customer to provide proof of payment. After payment verification is completed, the payment may be moved from the incorrect billing account to the customer's correct billing account to ensure the funds are credited appropriately. If it is confirmed that the customer is impacted by a mixed meter or mixed customer scenario, the billing account is updated as outlined in the Company’s Customer Service Policies provided in the initial filing dated July 14, 2026: - Customer Service Policy 270.3 Investigating and Correcting Mixed Meter Conditions Customer Service Policy 110.3 BackbillingPage 9 of 33
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set OCC-25 Date Issued October 05, 2026 OCC-917 Page 1 of 1 Date Filed: October 19, 2026 Witness: Jared A. Lawrence and Timothy W. McGrath Request from: Office of Consumer Counsel Question: (ACCOUNT NUMBERS) How does the Company prevent incorrect accounts from being created for customers or other potential errors linked to incorrect account numbers? Response: When a customer establishes service, the Company verifies the customer of record and confirms the service address. The customer is then provided a billing account number, and a service account number is created to identify the location where service is being provided.Page 10 of 33
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set OCC-25 Date Issued October 05, 2026 OCC-918 Page 1 of 1 Date Filed: October 19, 2026 Witness: Christopher E. Colorio, Mark P. Baldwin, John G. Griffin and Leanne M. Landry Request from: Office of Consumer Counsel Question: (MS24C - Misprint) Referring to Exhibit ACCT-2 (CLP-3A-1) (MS24C) CONFIDENTIAL, page 445. Why does this page have purple edits on it and who added those edits? Response: Referring to Exhibit ACCT-2 (CLP-3A-1) (MS24C), Outside Contractor- Vendors, Line 163, vendor C C Security Corp., invoice total $200. As part of the invoice review process, the reviewer verifies the service locations, dates of service, and the legitimacy of the charges through confirmation with the personnel responsible for procuring the services. During this review, the reviewer may document the appropriate accounting information to ensure charges are directly assigned to the correct work order. These notations serve as additional evidence that the invoice was reviewed and verified for proper charging prior to approval.Page 11 of 33
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set OCC-25 Date Issued October 05, 2026 OCC-919 Page 1 of 1 Date Filed: October 19, 2026 Witness: John P. Dipaola-Tromba, John G. Griffin and Leanne M. Landry Request from: Office of Consumer Counsel Question: (MS24C - Misprint) Referring to Exhibit ACCT-2 (CLP-3A-8) (MS24C), Confidential page 81. Why does this page have purple edits on it and who added those edits? Response: Referring to Exhibit ACCT-2 (CLP-3A-8) (MS24C), Contractor Outside- Vendor, line 384, vendor McAllen Construction Inc, total invoice amoun of $1,970. As part of the invoice review process, the reviewer verifies the service locations, dates of service, and the legitimacy of the charges through confirmation with the personnel responsible for procuring the services. During this review, the reviewer may document the appropriate accounting information to ensure charges are directly assigned to the correct work order. These notations serve as evidence that the invoice was reviewed and verified for proper charging prior to approval.Page 12 of 33
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set OCC-25 Date Issued October 05, 2026 OCC-920 Page 1 of 1 Date Filed: October 19, 2026 Witness: Christopher E. Colorio, Mark P. Baldwin, John G. Griffin and Leanne M. Landry Request from: Office of Consumer Counsel Question: (MS24C - Misprint) Referring to Exhibit ACCT-2 (CLP-3A-8) (MS24C) Confidential, page 172. Why is there writing outside the boxes on the form? Response: Refer to Exhibit ACCT-2 (CLP-3A-8) (MS24C), Outside Contractors- vendors, line 393, vendor New England Flaggers Services, total invoice amount $2,888. Contractors may include additional notations on their supporting documentation for their own operational or recordkeeping purposes. The presence or absence of such notations on supporting documentation is not determinative of the validity of the charges. As part of the Company's invoice review and approval process, locations, dates of service, and work order assignments are verified with the Company's internal personnel who engaged the contractor to confirm that the services were performed and that the charges are legitimate and properly charged.Page 13 of 33
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set OCC-25 Date Issued October 05, 2026 OCC-921 Page 1 of 1 Date Filed: October 19, 2026 Witness: Christopher E. Colorio, Mark P. Baldwin, John G. Griffin and Leanne M. Landry Request from: Office of Consumer Counsel Question: (MS24C - Revisions) Referring to Exhibit ACCT-2 (CLP-3A-8) (MS24C) Confidential page 77. Why are there cross outs and other revisions on this page and who made them? Response: Refer to Exhibit ACCT-2 (CLP-3A-8) (MS24C), Outside contractor- Vendor, line 383, vendor M J Electric LLC, total invoice amount of $47,874. Invoice 25170108412-1R, was a revised invoice for which discrepancies were identified and subsequently reviewed with the contractor. Upon resolution of those discrepancies, the contractor elected to make handwritten adjustments and annotations directly on the originally submitted invoice and resubmitted the revised document reflecting those changes. The contractor is not prohibited from making such handwritten revisions to an invoice. Notwithstanding the handwritten revisions to the invoice, the invoice remained subject to the Company's standard invoice review and approval process, including validation of supporting documentation, verification of charges, and confirmation that the invoiced amounts were appropriate and accurately billed.Page 14 of 33
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set OCC-25 Date Issued October 05, 2026 OCC-922 Page 1 of 1 Date Filed: October 19, 2026 Witness: David L. Gladey, John P. Dipaola-Tromba, Leanne M. Landry and Jeffrey D. Turano Request from: Office of Consumer Counsel Question: (Capital Projects) Referring to Exhibit CLP-Additions-1, pages 17-23. Did the Capital Project Authorization Procedures change since 2022? Response: The Capital Project Authorization Policy has not changed since 2022. There were minor changes made to the Project Authorization Policy (APS 1) on May 28, 2024. The May 28, 2024 update was solely to make certain tables, in the Project Authorization Form, excel add-ins instead of manual adding up those tables.Page 15 of 33
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set OCC-25 Date Issued October 05, 2026 OCC-923 Page 1 of 2 Date Filed: October 20, 2026 Witness: David L. Gladey, John P. Dipaola-Tromba, Leanne M. Landry and Jeffrey D. Turano Request from: Office of Consumer Counsel Question: (Capital Projects) Referring to Exhibit CLP-Additions-1, pages 27-29. The Company states that the PAF policy is applied when "the full budget and scope" of a project might not be known. Please explain how the Company makes a determination on whether a project requires a PAF or not during the preliminary stages of a project when the full budget and scope are not yet known. As part of this response, identify if there is a "high-level" or initial project costs developed for this purpose and, if so, explain how this estimate is developed. Response: Projects that will have a total cost of $500K or more will be required to follow the PAF process. The Company uses historical projects as a proxy to identify those projects that would meet or exceed $500K threshold for additional review and process. Please refer to OCC-925 i and OCC-925, Attachments 1 and 2, for the process overview and procedure documents. Prior Referenced Response: i OCC-925 Question: (Capital Projects) Referring to Exhibit CLP-Additions-1, page 28. The Company states, “Projects less than $500,000 in total cost do not have as many opportunities for cost savings because these are smaller, short-term projects with more predictable budgets. These smaller capital projects are more likely to be routine and utilize equipment and materials previously competitively procured by the Company or ESC. This minimizes the potential for cost savings that could result from further review and analysis.” Please describe the "further review and analysis" the company conducts to determine the potential for cost savings. Provide five examples of projects submitted in this proceeding where cost savings were achieved through this review and analysis step. OCC-925 Response: Projects with a total estimated cost of less than $500,000 are typically limited in scope and are generally associated with routine replacement of failed, damaged, or end-of-life equipment. These "break/fix" projects are usually undertaken to restore or maintain the reliability and safe operation of the electric system. Because the equipment being replaced is generally required to perform a specific function and must meet established engineering andPage 16 of 33
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set OCC-25 Date Issued October 05, 2026 OCC-923 Page 2 of 2 operational standards, there are often limited alternative solutions available. As a result, there are generally fewer opportunities for additional cost savings through further review and analysis. For larger capital projects with estimated costs greater than $500,000, the Company conducts a more comprehensive review in accordance with the Distribution Tri State Capital Project Approval Process (Distribution Lines) or Capital Project Approval Process (Distribution Substations). As part of this process, the Company evaluates multiple alternatives and project configurations to identify the solution that best addresses the identified system need while providing the most cost-effective outcome. This review may include evaluation of different engineering designs, equipment options, system configurations, project timing considerations, and operational impacts. The selected alternative is based on an assessment of factors such as reliability, safety, operational requirements, constructability, environmental considerations, and overall project cost. Please refer to OCC-925, Attachment 1 – Distribution Tri-State Capital Project Approval Process Please refer to OCC-925, Attachment 2 – Capital Project Approval Process Please refer to the following projects as examples of projects greater than $500,000 that underwent the alternatives analysis review process and achieved cost savings through the evaluation of multiple project options. The documentation for these projects is included in Exhibit CLP-ADDITIONS-4, as identified in the references below. Additionally, each line reference corresponds directly to the associated supporting folder in Exhibit CLPADDITIONS-6. - CD02190 - Middle River 28M3 Load Relief: Exhibit 4 tab “Project Specifics Post 2022”, line 286 - CD02164- Norwalk 9S27 Normal overload: Exhibit 4 tab “Project Specifics Post 2022”, line 281 - CD02577 - Amazon EV Chargers, Victoria Dr, Monroe: Exhibit 4 tab “Project Specifics Post 2022”, line 374 - CD02153 - Stone Bridge Commons New Service: Exhibit 4 tab “Project Specifics Post 2022”, line 278 - CS00577 - Rockville 14W-6X Transformer Voltage Change: Exhibit 4 tab “Project Specifics Post 2022”, line 416Page 17 of 33
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set OCC-25 Date Issued October 05, 2026 OCC-924 Page 1 of 2 Date Filed: October 20, 2026 Witness: David L. Gladey, John P. Dipaola-Tromba, Leanne M. Landry and Jeffrey D. Turano Request from: Office of Consumer Counsel Question: (Capital Projects) Referring to Exhibit CLP-Additions-1, page 12. Please define the term "flexibility in the budget"; explain what determines whether a project has budget flexibility or not; and identify the components (i.e. project cost categories) of a project budget which are flexible and which are inflexible. Response: The term “flexibility in the budget” is a reference to the overall capital budget, not the budget for a specific project. The term refers to the ability to defer, accelerate, or reprioritize planned capital spending within a given budget period in response to changing system conditions, emerging operational needs, or unforeseen project requirements. Budget flexibility is an important component of managing a large capital portfolio and enables the Company to efficiently allocate capital to projects that provide the greatest near-term benefit to customers and system operations. Whether a specific project has flexibility in relation to the overall budget depends primarily on the urgency of the underlying need, regulatory or compliance requirements, customer commitments, safety considerations, and the potential system impacts associated with delaying the work. Projects that address immediate safety concerns, mandated compliance requirements, emergent reliability issues, customer-driven obligations, or equipment failures generally have limited or no budget flexibility because delays could result in unacceptable operational, safety, or customer impacts. In contrast, projects addressing aging infrastructure that remain in serviceable condition may have greater flexibility because the assets can continue to operate safely and reliably for a period beyond the originally planned replacement date. For aging infrastructure replacement projects, budget flexibility typically exists when asset condition, engineering assessments, operational history and system performance indicate that the asset can remain in service without creating an immediate reliability, safety, or compliance concern. In these situations, The Company may defer a planned replacement project by one or more years with limited near-term impact on customer reliability while continuing to monitor the asset through its normal maintenance and inspection programs. Budget categories that are generally considered more flexible include planned construction expenditures associated with asset replacement programs, such as labor, materials, equipment, and
Text of OCC Set 26_COMBINED.pdf
Extracted from the file · 11 pages · 14,212 characters
Text of PURA Set 6_COMBINED.pdf
Extracted from the file · 82 pages · 163,601 characters
Text of PURA Set 7_COMBINED.pdf
Extracted from the file · 141 pages · 373,939 characters
Text of UCONN Set 1_COMBINED.pdf
Extracted from the file · 45 pages · 105,510 characters
Text of UCONN Set 2_COMBINED.pdf
Extracted from the file · 19 pages · 40,074 characters
As listed on the current system
Corres. 10/21/2026 [26-05-10] (Keegan Werlin LLP) - Compilation of Discovery Responses