Compilation of Discovery Responses
Files15
Docket No. 26-05-10 Discovery Compilations October 21 2026.pdf
PDF · 157 KB · 2 pagesText searchable
Download Docket No. 26-05-10 Discovery Compilations October 21 2026.pdfRead the text of Docket No. 26-05-10 Discovery Compilations October 21 2026.pdf
ALLCO Set 7_COMBINED.pdf
PDF · 291 KB · 24 pagesText searchable
Download ALLCO Set 7_COMBINED.pdfRead the text of ALLCO Set 7_COMBINED.pdf
CIEC Set 5_COMBINED.pdf
PDF · 112 KB · 2 pagesText searchable
Download CIEC Set 5_COMBINED.pdfRead the text of CIEC Set 5_COMBINED.pdf
CLF-AC Set 2_COMBINED.pdf
PDF · 394 KB · 18 pagesText searchable
Download CLF-AC Set 2_COMBINED.pdfRead the text of CLF-AC Set 2_COMBINED.pdf
EOE Set 7_COMBINED.pdf
PDF · 1.4 MB · 150 pagesText searchable
Download EOE Set 7_COMBINED.pdfRead the text of EOE Set 7_COMBINED.pdf
NECTA Set 4_COMBINED.pdf
PDF · 409 KB · 14 pagesText searchable
Download NECTA Set 4_COMBINED.pdfRead the text of NECTA Set 4_COMBINED.pdf
NECTA Set 5_COMBINED.pdf
PDF · 533 KB · 27 pagesText searchable
Download NECTA Set 5_COMBINED.pdfRead the text of NECTA Set 5_COMBINED.pdf
OCC Set 22_COMBINED.pdf
PDF · 627 KB · 40 pagesText searchable
Download OCC Set 22_COMBINED.pdfRead the text of OCC Set 22_COMBINED.pdf
OCC Set 23_COMBINED.pdf
PDF · 257 KB · 8 pagesText searchable
Download OCC Set 23_COMBINED.pdfRead the text of OCC Set 23_COMBINED.pdf
OCC Set 25_COMBINED.pdf
PDF · 323 KB · 33 pagesText searchable
Download OCC Set 25_COMBINED.pdfRead the text of OCC Set 25_COMBINED.pdf
OCC Set 26_COMBINED.pdf
PDF · 240 KB · 11 pagesText searchable
Download OCC Set 26_COMBINED.pdfRead the text of OCC Set 26_COMBINED.pdf
PURA Set 6_COMBINED.pdf
PDF · 1.5 MB · 82 pagesText searchable
Download PURA Set 6_COMBINED.pdfRead the text of PURA Set 6_COMBINED.pdf
PURA Set 7_COMBINED.pdf
PDF · 1.4 MB · 141 pagesText searchable
Download PURA Set 7_COMBINED.pdfRead the text of PURA Set 7_COMBINED.pdf
UCONN Set 1_COMBINED.pdf
PDF · 597 KB · 45 pagesText searchable
Download UCONN Set 1_COMBINED.pdfRead the text of UCONN Set 1_COMBINED.pdf
UCONN Set 2_COMBINED.pdf
PDF · 372 KB · 19 pagesText searchable
Download UCONN Set 2_COMBINED.pdfRead the text of UCONN Set 2_COMBINED.pdf
Text of CLF-AC Set 2_COMBINED.pdf
Extracted from the file · 18 pages · 32,497 characters
Text of EOE Set 7_COMBINED.pdf
Extracted from the file · 150 pages · 432,851 characters
Text of NECTA Set 4_COMBINED.pdf
Extracted from the file · 14 pages · 26,843 characters
Text of NECTA Set 5_COMBINED.pdf
Extracted from the file · 27 pages · 51,321 characters
Text of OCC Set 22_COMBINED.pdf
Extracted from the file · 40 pages · 63,151 characters
Text of OCC Set 23_COMBINED.pdf
Extracted from the file · 8 pages · 12,023 characters
Text of OCC Set 25_COMBINED.pdf
Extracted from the file · 33 pages · 57,780 characters
Text of OCC Set 26_COMBINED.pdf
Extracted from the file · 11 pages · 14,212 characters
Text of PURA Set 6_COMBINED.pdf
Extracted from the file · 82 pages · 163,601 characters
Page 26 of 141
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set PURA-07 Date Issued September 22, 2026 UPA-023 Page 4 of 4 Reliability Stable or Improving Reliability Declining Spending average below peer Lower spending is meeting system need. Under-investment signal. Deferred work Most likely where input prices are stable, is showing up as reduced performance. the utility can lock in long-term procurement, load is changing slowly, and assets are not yet at end of life. Spending average above peer Investment catching up or improving Over-investment signal. Spending is not performance. The test is whether each producing results. dollar buys a commensurate benefit. CL&P is not operating in the stable environment described by the “spending below peer average” and “reliability stable or improving” quadrant above (the upper left quadrant). Rather, it is moving toward the “spending below peer average” and “reliability declining” quadrant. Distribution equipment prices have risen well above general inflation, are changing, and much of the asset base is at or near end of life (Ex. CLP-IAP-1, p. 45, l. 18 – p. 46, l. 9; Ex. CLPELP-1, p. 42, ll. 4–20). Blue-sky SAIDI was 77.5 minutes in 2025, against a 2021–2025 average of 71.1 minutes, which indicates that SAIDI may be showing signals of decline (Ex. CLP-TSP-1, p. 76, Table 1), while SAIFI remained flat (Ex. CLP-ELP-1, p. 48, 11ll. 3-9). It is important to note, however, that external factors also affect SAIDI/SAIFI performance and this must be factored into the analysis. Below-average capital spending together with reliability showing initial signs of decline indicates that there is a need for elevated levels of investment in the future. The specific signs Exhibit CLP-IAP-1 relies upon are (page citations are to Ex. CLP-IAP-1 unless noted): 1. Constrained investment period. The Company refrained from increasing its distribution investment in recent years (Ex. CLP-IAP-1, p. 12, ll. 13–16). 2. Equipment cost inflation. Because of the equipment price increases noted above, a similar nominal budget supports less work over time (p. 45, l. 18 – p. 46, l. 9). 3. O&M pattern. Higher O&M relative to peers, alongside modest capital spending, can be consistent with an aging system that needs more maintenance to stay in service (p. 56, ll. 7–10), although cross-utility O&M comparisons also reflect differences in service territory characteristics, regulatory requirements, company capitalization policy, labor costs and policy-program accounting (pp. 54–56). Increasing emergent failures also take resources away from proactive replacement (Ex. CLP-TSP-1, p. 22, ll. 14–16). 4. Asset condition and reliability. The Company’s planning testimony documents an aging distribution system, with major asset classes at or beyond their expected service lives, rising equipment failures, and reliability that remains in the top quartile but has begun to slip, (Ex. CLP-ELP-1, pp. 42, 48–49; Ex. CLP-TSP-1, p. 35; Ex. CLP-TSP-3, slide 58). The asset-level detail is presented by the Leadership Panel and the System Engineering Panel. The point for the framework is the direction of those indicators. The data show a pattern associated with the underinvestment side of the calibrated range rather than one of stability or overinvestment. Taken together, these signs place CL&P within the calibrated range but moving toward its underinvestment side. Exhibit CLP-IAP-1’s opinion is directed at the framework and at whether the proposed plan sits within the calibrated range; it is not centered on the amount of investment the Company has identified (p. 16, ll. 10–15). The support for the specific amounts proposed is presented in the Company’s planning testimony (Exs. CLP-ELP-1; CLP-TSP-1 through TSP-3) Exhibit CLP-IAP-1 did not rely on separate calculations for this conclusion; it relies on the record evidence cited above, including the LEI benchmarking results and workpapers (Ex. CLP-PBR-3) and the reliability data in Ex. CLP-TSP-1, Table 1.Page 27 of 141
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set PURA-07 Date Issued September 22, 2026 UPA-024 Page 1 of 4 Date Filed: October 06, 2026S Witness: Matthew Nelson and Michael Goldman Request from: Public Utilities Regulatory Authority Question: Reference Application, Ex. CLP-IAP-1, pp. 27–28. Explain how the Authority should determine whether a proposed capital investment is efficient for affordability purposes. Also, provide the following: a. Identify the specific cost, benefit, performance, or alternative-investment information Eversource recommends that the Authority considers in that evaluation; and b. explain how that comparison distinguishes an efficient investment from one that is “prudent and effective but not highly efficient.” Response: Exhibit CLP-IAP-1 uses three distinct terms (p. 28, ll. 9–18): prudent, effective and efficient. An investment is prudent if the decision was reasonable when made. It is effective if it delivers the reliability or service benefit it was meant to achieve. It is efficient if it delivers that benefit at an appropriate cost relative to the alternatives. The concept is that PURA should determine efficiency at three levels: (1) whether each project is the lower-cost way to meet its need; (2) whether the portfolio as a whole funds the highest-value work first within the approved budget; and (3) whether one investment can meet several needs. A. This approach asks that PURA consider the following in determining whether a proposed capital investment is efficient for affordability purposes: • Cost: Project cost estimates, unit costs compared with the Company’s own history and a lifecycle cost, including the O&M the investment avoids or adds. • Benefit: Expected reliability improvement (SAIDI, SAIFI, customer minutes of interruption avoided), monetized customer interruption costs, safety and risk reduction, and capacity needed to meet State policy such as electrification. • Performance: Historical results after installation compared with the forecast benefit (p. 57, ll. 3–8). Those results also feed back into the Company’s benefit-cost model, recalibrating its estimates of reliability benefit per dollar over time.Page 28 of 141
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set PURA-07 Date Issued September 22, 2026 UPA-024 Page 2 of 4 • Alternatives: Repair versus replacement, non-wires alternatives, deferral with a stated risk, different technology, and bundling of work to reduce mobilization and outage costs. • Prioritization: The rationale for ranking work, such as customer benefit per dollar within the budget. The Company’s benefit-cost model evaluates historic outages zone by zone rather than circuit by circuit, uses the Company’s data on upgrades made over the past 20 years to estimate SAIDI and SAIFI benefits per dollar, and can be run against a stated reliability objective (Ex. CLP-TSP-1, p. 34, ll. 6–16). The Company’s model compares work types at the device level, including reconductoring and backbone and lateral automation (TSP-1 p. 60, ll. 3–7). Resiliency work is ranked using an AllIn SAIDI model that combines blue-sky and grey-sky SAIDI with a 1-in-10-year catastrophic storm (Ex. CLP-ELP-1, p. 62, ll. 16–22; p. 72, ll. 10–18). • Multi-Needs: Efficiency also includes whether one investment can meet several needs. Replacing an aging asset with one sized for expected load, such as electrification, can avoid a second investment later, while like-for-like replacement can be the lower-cost choice where that need is not expected. The Company’s plan targets locations with multiple needs, such as asset health, capacity, voltage and reliability, so that one investment resolves them together (Ex. CLP-TSP-3, slide 34). • Metrics: The Company’s plan also uses cost-efficiency metrics such as dollars per customer-minute of interruption saved, risk-based analytics that weigh the probability and consequence of failure, and planning at the protection-device (zone) level (Ex. CLP-TSP-3, slide 34). To track efficiency after investments are made, the Company has also proposed reporting metrics for capital expense per customer and per line mile, alongside its reliability performance incentive mechanisms, as sponsored by the Leadership Panel (Ex. CLP-ELP-1, p. 103, ll. 10–16; Ex. CLP-ELP-3). The Company’s planning applies this comparison. For each zone, the model identifies the most cost-effective upgrade, which could be anything from tree trimming to a full rebuild (Ex. CLPTSP-1, p. 34, ll. 16–18). For capacity projects, planners use every available load transfer among stations before upgrading a substation transformer (TSP-1 p. 34, l. 21 – p. 35, l. 3). The Company’s resiliency proposal illustrates the comparison. Spacer cable reconductoring delivers nearly twothirds of the resiliency benefit of undergrounding for about one-third of the cost (Ex. CLP-ELP-1, p. 63, ll. 14–18). The hardening program is projected to avoid approximately 12.4 million customer-minutes of interruption per year, about $37.1 million per year at the Company’s estimate of $3 per customer-minute (ELP-1 p. 64, ll. 8–11). B oth undergrounding and spacer cable would be effective; spacer cable is the more efficient choice for most zones.Page 29 of 141
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set PURA-07 Date Issued September 22, 2026 UPA-024 Page 3 of 4 B. Distinguishing “efficient” from “prudent.” The benefit of an investment is harder to measure than its cost. Refer to Ex. CLP-TSP-1, p. 86, ll. 4–7. The benefit-cost analysis reduces uncertainty; it does not eliminate it. Distribution assets serve customers for decades, and decisions about them are made with the information available today. Not every capital investment is made to improve measured reliability. Connecting new customers, adding capacity to serve load growth or to host distributed generation, and relocating facilities for public works projects are required to provide service, and their benefit does not appear in outage metrics. Further the benefits of a reliability or resiliency investment depend on events whose location and timing cannot be known in advance, so a sound investment may show little measurable benefit over a narrow period. For that reason, effectiveness is better assessed over time and across the system than project by project. The reliability metrics the Company proposes measure performance at the system level (Ex. CLP-ELP-3). The Company refines its estimates as performance data accumulate. The benefits of an asset that may be in service for decades are spread across the many outages it helps avoid. Efficiency asks the further question of whether the same benefit could have been obtained at lower cost, or whether a higher-value project was displaced. An investment can be prudent and effective but not highly efficient where, for example, an asset is replaced when a targeted repair would have maintained performance, or where a project with lower benefit per dollar is funded ahead of one with higher benefit per dollar. The comparison that distinguishes efficient from effective is therefore made when the work is planned: the ranking of projects by benefit per dollar and the consideration of lower-cost alternatives. Cost-efficiency must also be looked at with a long-term lens. Without programmatic or technological changes, PURA should expect the marginal benefit per dollar to decline over time as the highest-value work is completed. A declining ratio across the plan is not by itself evidence of inefficiency; the relevant check is that the portfolio remains ordered by value and that funded projects continue to produce net benefits. Two factors offset that decline. As performance results feed back into the model, its estimates become more precise, allowing investment to be targeted more exactly. And the model becomes more important, not less, once the most obvious opportunities have been completed. When reviewing this model, three features safeguard against a benefit-cost model being tilted toward more spending. First, the model’s benefit estimates come from the Company’s own data on upgrades made over the past 20 years (Ex. CLP-TSP-1, p. 34, ll. 10–12; Ex. CLP-ELP-1, p. 67, ll. 17–19). Second, customer outage costs are valued using Lawrence Berkeley National Laboratory’s Interruption Cost Estimate calculator, an independent source (Ex. CLP-TSP-1, p. 39, ll. 9–13), and inputs such as the value per customer-minute are on the record for review. Third, results are checked after the fact: the amount of revenue support provided for ongoing capitalPage 30 of 141
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set PURA-07 Date Issued September 22, 2026 UPA-024 Page 4 of 4 investments for the duration of the PBMRP capital is capped at the approved forecast, reliability is measured through the proposed SAIDI, SAIFI and customer reliability PIMs, and performance is reported annually (Ex. CLP-ELP-1, p. 50, ll. 1–9; pp. 101–102). The Company has also noted that AMI data would improve its ability to measure the benefit customers actually experience from automation investments (Ex. CLP-TSP-1, p. 86, ll. 4–11).Page 31 of 141
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set PURA-07 Date Issued September 22, 2026 UPA-025 Page 1 of 5 Date Filed: October 06, 2026 Witness: Matthew Nelson and Michael Goldman Request from: Public Utilities Regulatory Authority Question: Reference Application, Ex. CLP-IAP-1, pp. 31–32 and 54. Identify each quantitative threshold, benchmark, or other criterion used to distinguish underinvestment, calibrated investment, and overinvestment under the Investment Calibration Framework. If Eversource establishes no such thresholds or criteria, state so. Explain how the results presented on page 54 of Ex. CLP-IAP-1 to determine where CL&P’s proposed capital investment falls within the framework. Response: The Investment Calibration Framework does not establish a numeric threshold, such as a dollar amount per customer or a percentage of rate base, separating underinvestment, calibrated investment and overinvestment. The framework is a way of organizing PURA’s review of the level of investment; it is not a formula that produces a number. That is deliberate. The appropriate level of investment depends on each system’s age, condition, load, weather exposure and policy requirements, so a single threshold would not be sound, and it would carry its own unintended consequences. Spending just under a fixed line could be treated as sufficient regardless of the system’s condition and spending just over it as excessive regardless of need. Setting investment levels is a judgment made within parameters, much as PURA sets other multi-year program budgets, i.e., the budget is built from historical experience and from the work needed going forward, and decisions are then made within that range. The framework’s focus was to create a methodology of quantifying and prioritizing the investments costs and benefits so that effective and efficient investments can be identified and prioritized, understanding all of the moving parts that change these estimates and potentially whether a project is cost effective. The focus was not meant to provide a single number. The Company’s proposed budgets target impacts in relation to what is deemed by analytical evaluation to be effective and efficient. The level of investment that is effective and efficient also depends on the objective it is measured against. The Company’s benefit-cost model identifies the most cost-effective work for a stated reliability objective, such as a given improvement in SAIDI or SAIFI, and it can be run against different objectives (Ex. CLP-TSP-1, p. 34, ll. 12–18; p. 60, ll. 3–5). What is cost-effective therefore depends on the selected objective. The Company’s planning presents the choice as aPage 32 of 141
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set PURA-07 Date Issued September 22, 2026 UPA-025 Page 2 of 5 range, which is how the framework expects the question to be approached. The Company identified three investment levels: (1) Sustained Performance, the baseline needed to sustain the system, which carries lower near-term spending but higher emergent-failure and capital risk; (2) the proposed level, which adds Enhanced Reliability and Resiliency to constituted the Targeted System Performance plan; and (3) a higher Advancing the Grid level that the Company does not propose in this proceeding. The framework does not determine the specific dollar amounts at any of those levels. The support for the amounts proposed, including how the capital forecast was developed, is presented by the Leadership Panel and the System Engineering Panel (Exs. CLPELP-1; CLP-TSP-1 through TSP-3; see also the response to UPA-033 i). The framework is neutral as to the answer. The crux of the analysis is the identification of a planning and investment approach and a vision on the “end state” that is envisioned as the proper regulatory outcome for customers. Therefore, in place of a fixed threshold, the framework identifies criteria that the Company recommends PURA apply collectively, several of which are quantitative: Criterion Indicates Insufficient Investment Indicates Calibration Indicates OverInvestment Project BenefitCost Results High-value projects repeatedly deferred Portfolio funded in order of value; funded projects above 1.0 Projects funded below 1.0 or lower-cost alternatives passed over Reliability and Asset Condition Deteriorating SAIDI/SAIFI, rising equipment-caused and fair-weather outages, growing replacement backlog Performance stable or improving against commitments Gains well beyond commitments at a relatively high cost Composition of Spending Existing system work is Spending mainly on Building for load that is maintaining and strengthening not there or not expected consistently deferred the existing system (p. 47, ll. 3–6) Cost Benchmarking Capital investment Costs near or below levels well below peers, benchmark with adequate alongside rising performance maintenance needs on an aging system (p. 56, ll. 7–10) Capital investment well above peers without commensurate performance The Company applies these criteria through two planning approaches. For reliability improvement, it selects projects using the benefit-cost model described in the response to UPA024, ranked by metrics such as dollars per customer-minute of interruption saved (Ex. CLP-TSP-Page 33 of 141
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set PURA-07 Date Issued September 22, 2026 UPA-025 Page 3 of 5 3, slides 34–35). The ranking sets the order in which work is funded toward the stated objective; it is not a rule that every project above a fixed benefit-cost ratio is built. For asset health, it runs programmatic replacement of asset classes with known degradation patterns, including bare copper overhead conductor, paper-insulated lead cable, right-of-way poles, direct-buried cable, padmounted switchgear and substation transformers. The pace of each program reflects historical spending patterns, with reasonable escalations for age and condition (p. 67, ll. 3–5; p. 69, ll. 11– 13) (Ex. CLP-TSP-3, 37, 57–62, 71). The asset programs, their pacing and the associated failure data are presented by the System Engineering Panel (Ex. CLP-TSP-1; Ex. CLP-TSP-3, slides 57–62, 71). Exhibit CLP-IAP-1 offers no opinion on the specific program lengths or budgets. It identifies the age and condition of assets pacing, weighed against cost, as the kind of consideration the Balance step relies on. Applied to CL&P, the benchmarking results describe the Company’s historical position. LEI’s unit cost benchmarking ranks CL&P 32nd of 88 utilities nationally and 8th of 22 in the Northeast on capital cost per customer, and 47th of 88 and 8th of 22 on total cost per customer. After controlling for labor prices, network density, scale and other drivers, CL&P’s capital costs averaged approximately 14 percent below the model-predicted benchmark and its total costs approximately 2 percent below it over 2015–2024 (Ex. CLP-PBR-3, pp. 9, 16-17) 1. Together with the condition of an aging system, those results place CL&P historically within the calibrated range, toward the under-investment side. The benchmarking results do not by themselves locate the proposed plan. The testimony’s conclusion that the proposed investment is calibrated rests on the combination of criteria above: the proposed reliability budget satisfies the RE08 affordability test and the investments carry benefit-to-cost ratios above 1.0 (Ex. CLP-IAP-7), the spending is directed at the existing system (Ex. CLP-IAP-1, p. 46, l. 10 – p. 47, l. 11), and the need is documented in Exhibits CLP-TSP-1 through TSP-3, including an aging asset base and rising SAIDI (Ex. CLP-ELP-1, p. 42, l. 4 – p. 43, l. 2; p. 48, ll. 3–9). Prior Referenced Response: i UPA-033 Question: Reference Application, Ex. CLP-IAP-1, pp. 30–31. Explain the role of performance-based regulation in the Investment Calibration Framework. State whether Eversource’s framework depends on implementation of a performance-based ratemaking structure to maintain capital investment within the calibrated range and identify any PIMs, metrics, or The benchmarking figures stated on pages 53–54 of Exhibit CLP-IAP-1 differ slightly from those in the filed benchmarking report, Exhibit CLP-PBR-3. The Exhibit CLP-PBR-3 figures are used in this response and supersede the corresponding figures in Exhibit CLP-IAP-1. The conclusion stated on page 54 is unchanged. 1Page 34 of 141
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set PURA-07 Date Issued September 22, 2026 UPA-025 Page 4 of 5 mechanisms used to evaluate capital investment. If not, identify how the framework maintains investment within the calibrated range absent performance-based regulation. UPA-033 Response: No ratemaking structure, performance-based or otherwise, determines whether a given investment is effective or efficient (UPA-024i). This determination comes as a result of the work of planning, engineering and execution, tested through the Company’s project justification and alternatives analysis and, ultimately, PURA’s prudence review. What a ratemaking mechanism determines is the financial environment in which those decisions are made and the underlying incentives inherent in the regulatory framework (Ex. CLP-IAP-1, p. 30, ll. 1–12). Performance-based regulation, properly designed, is the structure that makes calibration achievable and holds it in place over the plan term (p. 30, l. 13 – p. 31, l. 3). The PBMRP follows the methodology of a comprehensive PBR plan, except that its formula applies to O&M only (Ex. CLP-ELP-1, p. 85, ll. 12–19). O&M revenue is adjusted annually by the I − X − S formula, with the Consumer Dividend as the S-Factor. Capital investment is addressed through the Capital Funding Mechanism, which limits recovery to the lesser of the approved forecast or actual plant in service and places the risk of excess capital spending on the Company (pp. 101–102). An index applied to capital would pass input-price changes through to customers; a fixed forecast does not. The capital forecast underlying the cap was developed by the Company’s engineering organization and is described by the Leadership Panel and the System Engineering Panel (Ex. CLP-ELP-1, pp. 64–72; Ex. CLP-TSP-1, pp. 39–61). The intent of the framework proposed by the Company is to advance a regulatory framework that affordably enables cost effective system investment to support the economic vitality of Connecticut, introduces PIMs for transparency and accountability for the duration of the plan, and retains appropriate incentives for the Company to control costs of both O&M and capital spending to the greatest extent possible over the course of the plan. The framework itself does not depend on performance-based regulation; it is an evaluation lens that PURA can apply under any ratemaking structure. However, the PBMRP is the Company’s proposed means of keeping investment within the calibrated range for CL&P over the plan term, balancing recovery of costs with rate stability and gradual year-over-year customer bill impacts. In addition, PBR drives efficiency in utilities working within these confines and supports cost discipline over time. Absent performance-based regulation, that evaluation would occur in base rate cases as part of the prudence review. The Company has stated that, without the PBMRP, it would expect to file rate cases as close to annually as possible (Ex. CLP-ELP-1, p. 85, ll. 1–3). The mechanisms and controls in the PBMRP that the Company relies upon to keep capital investment within the calibrated range, and to provide transparency and accountability for performance are: • Capital Funding Mechanism. Revenue is capped based on the approved capital expenditure forecast with an annual, downward-only reconciliation (Ex. CLP-ELP-1, pp. 101–102). • Reliability PIMs: System Reliability PIMs for blue-sky SAIDI and SAIFI with performance-based benchmarks, and a Customer Reliability PIM targeting repeat CEMI and CELID customers, offered as part of the PBMRP (Ex. CLP-ELP-1, p. 50, ll. 1–9; pp. 106–107, Table 3). These tie the Company’s financial results to the reliability the capital program is meant to support. The SAIDI and SAIFI PIMs are penaltyonly, with penalties of $1.75 million to $3.5 million each; the Customer Reliability PIM is incentive-only, with an incentive of $1.5 million to $3.0 million. • Performance Metrics: 16 proposed metrics across three categories, with descriptions, targets and PIM design in Exhibit CLP-ELP-3 (Ex. CLP-ELP-1, p. 103, ll. 10–16). • Reporting: Capital spending against the approved plan and reliability against commitments, with regular public reporting (p. 57, ll. 3–8); cost-efficiency metrics, reported without targets or penalties (Ex. CLP-ELP1, p. 112, Table 5; p. 113, l. 5 – p. 114, l. 16).Page 35 of 141
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set PURA-07 Date Issued September 22, 2026 UPA-025 Page 5 of 5 • Project-Level Review: The reliability benefit-cost model on the record (Ex. CLP-ELP-1, p. 67, ll. 17–19; Ex. CLP-TSP-1, p. 60, ll. 3–7) and prudence review. The Company’s proposals set forth a comprehensive framework in this proceeding, leveraging the Company’s experience, and that of its expert consultants work in other jurisdictions, while conforming as closely as possible to the proposed final decisions in PURA’s PBR proceedings, in order to propose a framework that could support the level of going-forward system investment needs while operating in a multi-year rate case stay out, which is a fundamental component of PBR frameworks adopted elsewhere. If PURA adopts a framework that materially differs from the Company’s proposals, or is not calibrated to support the level of investment needed in the system on a going forward basis, the Company will not be in a position to commit to a rate case stay-out period of four years, which will result in more frequent rate cases, in which all components of the Company’s costs will be updated to then-current levels.
Text of UCONN Set 1_COMBINED.pdf
Extracted from the file · 45 pages · 105,510 characters
Text of UCONN Set 2_COMBINED.pdf
Extracted from the file · 19 pages · 40,074 characters
As listed on the current system
Corres. 10/21/2026 [26-05-10] (Keegan Werlin LLP) - Compilation of Discovery Responses