The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set PURA-11 Date Issued October 06, 2026 UPA-068 Page 1 of 4 Date Filed: October 20, 2026 Witness: Julia Frayer Request from: Public Utilities Regulatory Authority Question: (CONSUMER DIVIDEND) Exhibit CLP-PBR-3; Interrog. Resp. OCC-559(b). The Company states that Figure 16 is an “illustrative sample” and “was not intended to include every North American PBR plan reviewed by LEI.” Provide a list of all North American PBR plans reviewed by LEI in connection with developing, evaluating, or supporting the proposed 0.30% Consumer Dividend, including plans not presented in Figure 16. For each plan, identify the jurisdiction, utility, applicable Consumer Dividend/stretch factor, and whether the plan was considered by LEI in selecting or evaluating the proposed 0.30% Consumer Dividend. Response: LEI clarifies that the plans and regulatory frameworks identified in Figure 16 of Exhibit CLPPBR-3, reproduced in OCC-559 i(a), constitute the complete set of plans reviewed in connection with developing, evaluating, or supporting the proposed 0.30% Consumer Dividend. No additional plans were reviewed for those purposes. The jurisdiction, utility, and applicable Consumer Dividend/stretch factor for each reviewed plan are identified in Figure 16. The reference in OCC559(b) to an “illustrative sample” was intended to distinguish the comparison from an exhaustive survey of North American utility regulatory frameworks, not to suggest that certain utility plans reviewed were omitted from Figure 16 or otherwise excluded from LEI’s evaluation of the Consumer Dividend within the Company’s PBMRP proposal. Prior Referenced Response: i OCC-559 Question: (Customer dividend) In Exhibit CLP-PBR-1, LEI states that approved Consumer Dividends or stretch factors in other North American jurisdictions generally range from 0.15% to 0.60%, as reflected in Figure 12 of Exhibit CLP-PBR-3: a. Please provide a list of each utility and jurisdiction included in deriving this range, including the applicable PBR plan or regulatory proceeding, the approved Consumer Dividend/stretch factor, and the year(s) in which it applied. b. Please explain the criteria used to select the utilities and PBR plans included in this comparison, including whether the comparison includes all relevant North American PBR plans reviewed by LEI or a subset. c. Please explain how the 0.15%–0.60% range, and CL&P’s position within that range, informed the selection of the proposed 0.30% Consumer Dividend, including any quantitative or qualitative analysis used to determine that 0.30% was appropriate for CL&P.Page 8 of 35
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set PURA-11 Date Issued October 06, 2026 UPA-068 Page 2 of 4 OCC-559 Response: a. Figure 16 (not Figure 12) in CLP-PBR-3, which we are also including below, provides the jurisdictions, utilities, approved Consumer Dividends/stretch factors, applicable terms, and regulatory sources considered by LEI. The comparison includes, among others, Alberta’s 2024–2028 PBR3 plan; FortisBC’s 2025–2027 Rate Setting Framework; Massachusetts PBR plans for Massachusetts Electric/Nantucket Electric, NSTAR Electric, and Fitchburg Gas and Electric; New Hampshire’s 2026–2029 alternative regulation plan for Public Service Company of New Hampshire; and the Ontario Energy Board’s stretch-factor framework for Ontario electricity distributors.Page 9 of 35
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set PURA-11 Date Issued October 06, 2026 UPA-068 Page 3 of 4 b. Figure 16 was intended to provide an illustrative sample, rather than an exhaustive survey, of relatively recent North American PBR frameworks employing a formulaic revenue or rate-adjustment mechanism and an explicit Consumer Dividend, stretch factor, or comparable benefit-sharing component. LEI selected these examples to provide regulatory context for the magnitude of CL&P’s proposed Consumer Dividend and to illustrate how such factors have been incorporated into PBR frameworks in other North AmericanPage 10 of 35
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set PURA-11 Date Issued October 06, 2026 UPA-068 Page 4 of 4 jurisdictions. The comparison was not intended to include every North American PBR plan reviewed by LEI or to establish the minimum and maximum Consumer Dividend. Indeed, some jurisdictions have approved PBR frameworks without an explicit Consumer Dividend, stretch factor, or comparable benefit-sharing component, further demonstrating that the range shown in Figure 16 should not be interpreted as establishing regulatory minimum or maximum values. c. LEI did not mathematically derive the proposed 0.30% Consumer Dividend from the 0.15%–0.60% range, nor was 0.30% selected specifically because it reflects the midpoint of that range. Rather, CL&P’s modest above-benchmark OM&A costs historically indicated potential for additional efficiency improvements in the future and supported a positive, moderate Consumer Dividend. It is important to keep in mind that the benchmarking results on their own do not establish the annual rate at which those improvements can reasonably be achieved. The Company has therefore proposed an incentive-rich mechanism by which the 0.3% Consumer Dividend is just a starting point, and if efficiency improvements are achieved then the Consumer Dividend would grow over time to ensure that customers are immediately sharing in the financial benefits of achieved cost efficiencies. LEI considered the regulatory precedents in Figure 16 as a reasonableness check on the magnitude of the proposed starting value for the Consumer Dividend. CL&P’s 0.30% falls within the observed range, and between the 0.25% FortisBC stretch factor and the 0.40% Massachusetts Electric/Nantucket Electric Consumer Dividend in the more directly comparable OM&A-focused frameworks. LEI therefore concluded that 0.30% was reasonable in light of CL&P’s benchmarking results and relevant regulatory precedent. Please also refer to the responses to OCC-443 and OCC-539.Page 11 of 35
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set PURA-11 Date Issued October 06, 2026 UPA-069 Page 1 of 2 Date Filed: October 20, 2026 Witness: Douglas P. Horton, Julia Frayer, Matthew Nelson and Michael Goldman Request from: Public Utilities Regulatory Authority Question: (CONSUMER DIVIDEND) Exhibit CLP-ELP-1, pp. 94; Interrog. Resps OCC-539. The Consumer Dividend increases by 0.10 percentage points when the Company’s Core Operating Expense per customer is below the applicable inflation-adjusted benchmark and decreases by 0.05 percentage points when it is not. Identify all quantitative analyses, calculations, empirical evidence, or regulatory precedents relied upon to establish the 0.10 and 0.05 percentage-point adjustments. Provide the results in an unlocked Excel workbook with all equations, calculations, links, and underlying assumptions/workpapers unhidden, unprotected, and in a reproducible format. Response: The Company relied on a qualitative assessment rather than a quantitative calculation to establish the 0.10 and 0.05 percentage-point adjustments, and no workbook was prepared for that purpose. The adjustments were set by judgment, applying several design considerations to create an incentive structure that shares operating efficiency gains with customers while maintaining an asymmetric adjustment mechanism that favors customers. First, the 0.10 percentage-point increase was sized to keep annual changes within the overall range of Consumer Dividends approved in other jurisdictions, which is 0.15 percent to 0.60 percent (Ex. CLP-PBR-3, pp. 37–38, Figure 16). The proposed Consumer Dividend starts at 0.30 percent and can adjust in each of the three Rate Years that follow the first. If the Company’s Core Operating Expense per customer is below the benchmark in every year, the Consumer Dividend increases to 0.60 percent, the top of the 0.15 to 0.60 range, and cannot exceed this maximum range. This comparison was used as a reasonableness and design consideration, not as a quantitative derivation of the 0.10 percentage-point adjustment. The Consumer Dividend is also capped at the composite measure of inflation for the year (Ex. CLP-ELP-1, p. 96, ll. 8–10). If the Company’s Core Operating Expense per customer is below the benchmark, the Consumer Dividend increases, providing customers with an immediate share of the benefits associated with improved operating efficiency during the plan term. The lower overall cost level due to those efficiencies is then reflected in base rates when rates are reset in the next rate case, ensuring efficiency gains carry forward to customers beyond the plan term. However, if operating costs do not decline, the Consumer Dividend steps down with a 0.05 percentage-point decrease. The 0.05 percentage-point decrease was intentionally set at half thePage 12 of 35
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set PURA-11 Date Issued October 06, 2026 UPA-069 Page 2 of 2 increase so that the mechanism is asymmetric and in customers’ favor. A year of weaker performance reduces the Consumer Dividend by less than a year of stronger performance raises it, so a single bad year does not erase prior customer benefits, and achieving operating efficiencies remains the more favorable financial outcome for the Company (Ex. CLP-ELP-1, p. 96, l. 14 – p. 97, l. 7; Ex. CLP-IAP-1, p. 76, l. 19 – p. 77, l. 7). The Consumer Dividend never falls below 0.30 percent (Ex. CLP-ELP-1, p. 94, ll. 7–9). Because the 0.10 and 0.05 percentage-point adjustments were established through judgment rather than a quantitative model, there are no calculation workpapers, supporting equations, derivation spreadsheets, or similar materials used to determine those values. Accordingly, the Company has no responsive workbook showing calculations used to establish the 0.10 and 0.05 percentage-point adjustments.Page 13 of 35
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set PURA-11 Date Issued October 06, 2026 UPA-070 Page 1 of 2 Date Filed: October 20, 2026 Witness: Julia Frayer Request from: Public Utilities Regulatory Authority Question: (I-FACTOR) Interrog. Resp. OCC-428; Interrog. Resp. OCC-537. The proposed I-Factor is constructed over a 20-year historical industry OM&A labor/non-labor split of approximately 33%/67%. Identify any analysis performed to determine whether these industry labor/non-labor cost shares are representative of the labor/non-labor composition of the Company’s Core Operating Expenses. Provide the results in an unlocked Excel workbook with all equations, calculations, links, and underlying assumptions/workpapers unhidden, unprotected, and in a reproducible format. Response: The Company's proposed I-Factor is designed to reflect industry-wide OM&A input price inflation rather than changes in the Company's own cost composition. As explained in the Company's response to OCC-428 i, the I-Factor combines the Employment Cost Index (“ECI”) for labor costs and the GDP Implicit Price Deflator for Final Sales to Domestic Purchasers (“GDP-FSDP”) for non-labor costs, weighted using the 20-year historical average labor/non-labor cost shares of the 88 electric distribution utilities included in LEI's Industry TFP Study (approximately 33%/67%). The use of industry-based weights is intentional and consistent with the methodology underlying the proposed X-Factor, which is also derived from industry-wide OM&A productivity trends. This approach establishes an external inflation benchmark that is not dependent on the Company's specific cost allocations or operating decisions. It also reinforces the competitive incentives underlying PBR by reducing the influence of Company-specific spending decisions on the inflation adjustment, thereby encouraging the Company to manage its costs efficiently relative to industry norms. For comparison, the Company's projected labor/non-labor cost shares for Core Operating Expenses in Rate Year 1 (ending June 2028) are approximately 35%/65%, broadly similar to the industry shares of 33%/67%. However, the two measures reflect different time periods and cost definitions, as the Company's Core Operating Expenses exclude certain separately recovered or noncontrollable costs, including vegetation management, major storm costs, and pension expenses. Accordingly, an exact match between the industry and Company cost shares is neither expected nor necessary for the proposed I-Factor.Page 14 of 35
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set PURA-11 Date Issued October 06, 2026 UPA-070 Page 2 of 2 LEI did not undertake a separate analysis reconciling the industry labor/non-labor shares to the Company's Core Operating Expenses. Please refer to OCC-428 Attachment 1, for the historical industry cost shares and calculation of the composite I-Factor. No separate reconciliation workbook was prepared. Prior Referenced Response: i OCC-428 Question: Exhibit CLP-ELP-1 Please provide the annual value of the composite O&M input price index used in the Company's proposed I-Factor for each of the past 20 years. Please also compare the annual composite O&M input price index to economy-wide inflation over the same period, including the annual percentage-point difference between the two measures. Please provide all calculations in an unlocked Excel workbook with formulas intact. OCC-428 Response: Please refer to OCC-428, Attachment 1, for the requested information. The table produced in OCC-428, Attachment 1, shows the comparison of the composite O&M input price index and the economy wide inflation for the 20-year period, 2006 to 2024. The Company’s proposed I factor is composed of the GDP Implicit Price Deflator for Final Sales to Domestic Purchasers (“GDP-FSDP”), as the non-labor cost index and the Employment Cost Index (“ECI”), as the labor cost index weighted to reflect the 20-year historical industry OM&A labor and non-labor split (33%/67%). Because the Company's proposed PBMRP applies the X Factor to OM&A costs, the corresponding I Factor is intended to measure changes in the prices of the same OM&A inputs whose productivity is measured by the X Factor. The requested 20-year historical I Factor values are provided for informational purposes. However, these values will be updated periodically during the PBMRP term. Specifically, the proposed I Factor is intended to reflect current changes in OM&A input prices and would be updated using more recent ECI and GDP-FSDP data, as that information is released by the BLS and BEA.Page 15 of 35
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set PURA-11 Date Issued October 06, 2026 UPA-071 Page 1 of 1 Date Filed: October 20, 2026 Witness: Julia Frayer, Matthew Nelson and Michael Goldman Request from: Public Utilities Regulatory Authority Question: (I-FACTOR/CONSUMER DIVIDEND FACTOR INTERACTION) Exhibit CLP-ELP-1, pp. 94– 95. The Core Operating Expense per-customer benchmark is adjusted annually by the equation I−X factor and that performance relative to this benchmark determines subsequent adjustments to the Consumer Dividend. Identify any quantitative analysis performed by LEI or the Company evaluating how changes in the I-Factor affect the Core Operating Expense benchmark and resulting Consumer Dividend adjustments. Provide the results in an unlocked Excel workbook with all equations, calculations, links, and underlying assumptions/workpapers unhidden, unprotected, and in a reproducible format. Response: The I-Factor is considered in the benchmark only at the approved Core Operating Expense per customer and is increased each year by the I-Factor less the productivity offset. The I-Factor is the same inflation index that applies in the O&M revenue adjustment; and notably it is external to the Company (e.g., the Company cannot influence it). Changes from varying levels of inflation flow through symmetrically: a higher I-Factor raises the benchmark and a lower I-Factor lowers it. Therefore, whether the Consumer Dividend then steps up or down depends on the Company's actual Core Operating Expense per customer compared with that benchmark. Because the benchmark moves only by the I-Factor less the productivity offset formula, the Company's own spending in one year does not change the benchmark (Ex. CLP-ELP-1 p. 94, l. 18 – p. 95, l. 2). It should be noted that the Company's actual costs will not move one for one with any inflation index or benchmark. The benchmark is the standard the Company’s performance will be measured against, and the difference between this benchmark and the Company’s actual costs determines the change in the Consumer Dividend. The incentive to operate below the benchmark comes from the incentive properties embedded in the I−X structure, and therefore the Consumer Dividend requires a sharing of the financial benefits associated with the incentives to customers during the course of the PBMRP. Please see UPA-071, Attachment 1, for the Company’s illustrative S factor model. Page 2, Line 22, shows how the I factor is used to adjust the Core Operating Expense Benchmark. Line 41, provides the resulting illustrative I-X-CD percentage increase, while Line 47, provides the impact of the Consumer Dividend for a given year.Page 16 of 35
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set PURA-11 Date Issued October 06, 2026 UPA-072 Page 1 of 3 Date Filed: October 22, 2026 Witness: Douglas P. Horton, Matthew Nelson and Michael Goldman Request from: Public Utilities Regulatory Authority Question: (CONSUMER DIVIDEND) Exhibit CLP-ELP-1. The Consumer Dividend is capped so that it does not exceed the applicable I-Factor for the year. Explain how the cap operates when the Consumer Dividend resulting from the ratchet exceeds the I-Factor (e.g., is it temporarily blocked, does it disappear, etc.). Provide an illustrative calculation and identify the Consumer Dividend used as the starting point for the following year’s ratchet. Provide the results in an unlocked Excel workbook with all equations, calculations, links, and underlying assumptions/workpapers unhidden, unprotected, and in a reproducible format. Response: The Consumer Dividend has two values in any year, which are: (1) the ratchet level; and (2) the applied Consumer Dividend. The Consumer Dividend is 30 basis points. The Consumer Dividend ratchet level is set by the Company’s performance against the Core Operating Expense per customer benchmark. Combined, the value starts at 0.30 percent, increases by 0.10 percentage points for a year in which Core Operating Expense per customer is below the benchmark, decreases by 0.05 percentage points for a year in which it is at or above the benchmark, and never falls below 0.30 percent (Exh. CLP-ELP-1, at 94, line 2–9; 96, line 3–13). The applied Consumer Dividend is the amount deducted in that year’s PBR adjustment and it equals the Consumer Dividend ratchet level unless the PBR cap applies. The PBR cap ensures that the annual O&M revenue adjustment is never negative. Under the PBR formula, the O&M revenue requirement is adjusted each year by I − X − CD (Ex. CLP-ELP-1, at 86, line 11–21). If the Consumer Dividend could exceed the inflation adjustment net of the productivity offset, the formula would reduce the Company’s O&M revenue in nominal terms in a year of very low inflation. That result would be inconsistent with the purpose of the PBMRP, which is to provide predictable rate changes for customers and revenue support for the Company’s operating costs over a multi-year term, while also enabling a multi-year rate case stay-out and the performance commitments provided for in the PBMRP (Exh. CLP-ELP-1, at 92, line 1–8). The PBR cap therefore limits the applied Consumer Dividend to I − X for the year, so that the total adjustment is not negative. When the Consumer Dividend ratchet level exceeds I − X for a year, the PBR cap operates as follows.
As listed on the current system
Corres. 10/23/2026 [26-05-10] (Keegan Werlin LLP) - Discovery Compilations