Discovery Compilation ALLCO Set 13, 16, 18, CIEC Set 7, DEEP Set 1, NECTA Set 6, OCC Set 29, PURA 8
Files9
Docket No. 26-05-10 Discovery Compilation November 6 2026.pdf
PDF · 134 KB · 1 pageText searchable
Download Docket No. 26-05-10 Discovery Compilation November 6 2026.pdfRead the text of Docket No. 26-05-10 Discovery Compilation November 6 2026.pdf
ALLCO Set 13_COMBINED.pdf
PDF · 801 KB · 49 pagesText searchable
Download ALLCO Set 13_COMBINED.pdfRead the text of ALLCO Set 13_COMBINED.pdf
ALLCO Set 16_COMBINED.pdf
PDF · 642 KB · 22 pagesText searchable
Download ALLCO Set 16_COMBINED.pdfRead the text of ALLCO Set 16_COMBINED.pdf
ALLCO Set 18_COMBINED.pdf
PDF · 306 KB · 25 pagesText searchable
Download ALLCO Set 18_COMBINED.pdfRead the text of ALLCO Set 18_COMBINED.pdf
CIEC Set 7_COMBINED.pdf
PDF · 230 KB · 7 pagesText searchable
Download CIEC Set 7_COMBINED.pdfRead the text of CIEC Set 7_COMBINED.pdf
DEEP Set 1 (BETP)_COMBINED.pdf
PDF · 1.9 MB · 174 pagesText searchable
Download DEEP Set 1 (BETP)_COMBINED.pdfRead the text of DEEP Set 1 (BETP)_COMBINED.pdf
NECTA Set 6_COMBINED.pdf
PDF · 446 KB · 22 pagesText searchable
Download NECTA Set 6_COMBINED.pdfRead the text of NECTA Set 6_COMBINED.pdf
OCC Set 29_COMBINED.pdf
PDF · 499 KB · 30 pagesText searchable
Download OCC Set 29_COMBINED.pdfRead the text of OCC Set 29_COMBINED.pdf
PURA Set 8_COMBINED.pdf
PDF · 2.5 MB · 230 pagesText searchable
Download PURA Set 8_COMBINED.pdfRead the text of PURA Set 8_COMBINED.pdf
Text of ALLCO Set 18_COMBINED.pdf
Extracted from the file · 25 pages · 65,407 characters
Text of CIEC Set 7_COMBINED.pdf
Extracted from the file · 7 pages · 8,262 characters
Page 150 of 174
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set DEEP-01 Date Issued October 06, 2026 BETP-049 Page 1 of 2 Date Filed: October 27, 2026 Witness: Jared A. Lawrence, Shamus O’Brien, Edward A. Davis and Kimberly R. Parsons Request from: Department of Energy and Environmental Protection Question: (TVR Customer Engagement Plan) Refer to CLP-RATES-8. Please explain how the Company will evaluate whether customers understand the structure and potential bill impacts of TVR rates including, but not limited to: a. the metrics, performance targets, and data sources the Company will use, including, at a minimum, customer survey results, enrollment and opt-out rates, customer inquiries and complaints, and actual bill impacts. b. how these results will be separately assessed for financial-hardship, medically protected, lowincome, limited-English-proficiency, and other customer groups requiring additional protections. c. the frequency of evaluation, how results will be reported to PURA, and what corrective actions the Company will take if customers demonstrate low understanding or experience material adverse bill impacts. Response: a. The Company intends to evaluate customer understanding of Time-Varying Rates (“TVR”) through a combination of customer research, customer feedback, and operational metrics. As described in CLP-RATES-8, the Company intends to monitor customer feedback, inquiry trends, participation patterns, customer research results, awareness measures, engagement metrics, and enrollment metrics to assess the effectiveness of its customer engagement efforts. Customer research may include surveys designed to measure customer awareness of TVR offerings, understanding of program design and potential bill impacts, familiarity with available TVR options, and recall of Company communications regarding TVR programs. Engagement metrics may include click-through rates, email open rates, event attendance, web views, and engagement with social media posts. Enrollment metrics may include the number of customers enrolled in a TVR rate, as well as enrollment and opt-out activity. The Company also intends to monitor customer inquiries and complaints received through both formal and informal channels. To the extent available, the Company may evaluate customer bill impacts and customer experiences to help assess the effectiveness of customer education and engagement efforts. As discussed in CLP-RATES-8, the most effective time to engage customers regarding the benefits of TVR options is following full deployment of Advanced Metering Infrastructure (“AMI”), when customers will be better positioned to realize the fullPage 151 of 174
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set DEEP-01 Date Issued October 06, 2026 BETP-049 Page 2 of 2 benefits of TVR offerings, framed for them using at least one year of their own interval usage data. Full implementation of AMI will also provide interval usage data that will enable the Company to better understand customer participation, including how customers may shift electricity usage in response to TVR price signals and the resulting impacts on customer bills. b. The Company intends to utilize customer account attributes maintained in its systems, including financial hardship and medical protection designations, to analyze and segment customer research results where appropriate. Such analysis may help identify customer segments that could benefit from additional education, outreach, or tailored communications regarding TVR programs. Although the Company does not maintain comprehensive languagepreference information for all customers, it intends to offer survey participation opportunities in both English and Spanish and will use available information to evaluate customer understanding across customer groups when feasible. c. The frequency of evaluation will depend on the metric being assessed and the timing and cadence of customer education, outreach, and engagement activities. The Company intends to monitor customer feedback, inquiries, complaints, and other relevant customer engagement metrics on an ongoing basis, while customer research activities, such as surveys, may be conducted periodically. The Company proposes reporting to PURA on its TVR Customer Engagement Plan, including all required documentation as directed by PURA, annually on June 1 following the Order in Docket No. 26-05-10. However, the Company notes that this reporting cadence may be adjusted or superseded by reporting requirements PURA may establish for a future AMI-related TVR customer engagement plan as an outcome of future AMI-related proceedings. The results of these evaluations will be used to inform and refine customer education, outreach, and engagement activities related to TVR offerings. Should the Company identify opportunities to improve customer understanding of TVR programs, it may modify communications, educational materials, outreach strategies, or other customer engagement efforts as appropriate.Page 152 of 174
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set DEEP-01 Date Issued October 06, 2026 BETP-050 Page 1 of 2 Date Filed: October 23, 2026 Witness: Jared A. Lawrence Request from: Department of Energy and Environmental Protection Question: (Phased AMI Enabled TVR Availability) Provide a summary timeline, using calendar dates, for completion of the principal capabilities needed for AMI-enabled TVR, including AMI meter deployment, interval-data availability, the MDMS, the CIS billing capability, the customer portal, and the rate-comparison tool. Response: A specific timeline for execution of the AMI Plan is contingent upon the date of receipt of an order from PURA approving the AMI Implementation Plan, and whether the approved plan is reasonable, balanced and accompanied by a fair, reasonable and appropriate cost recovery framework. The following dates assume that PURA’s approval of the AMI Implementation Plan will occur on July 1, 2027, and that the Plan is executable as issued, including the interrelated technology solutions. In particular, the timeline included in the AMI Implementation Plan assumes that the capabilities and integrations established for Massachusetts will be leveraged for Connecticut customers, rather than having to design and implement new ones, which would require an additional year or more to restart project development. Furthermore, the following target dates are subject to final determination of business and technical requirements specific to the Connecticut deployment, and may be influenced by other factors outside the Company’s control: • • • • • • • AMI meter deployment – first customers receive meters: January 31, 2030 AMI meter deployment – substantially complete: January 31, 2033 Interval data availability – first customers: January 31, 2030 Interval data availability – substantially all customers: January 31, 2033 MDMS: January 31, 2030 CIS billing: January 31, 2030 Customer portal: January 31, 2030 Rate comparison tool: The availability of the rate comparison tool will be contingent upon the approval of one or several TVR options that can be used to validate the design and testing of the Connecticut-specific instance of the tool. The Company expects to have the foundational capabilities available in relation to the modernized CIS, MDMS and customer portal, by virtue of its Massachusetts implementation. However, the Company will require intelligence specific to Connecticut on TVR design and opt-in/out policy (and potentially other factors based on future TVR discussions) before finalizing the tool’s design. If PURA adopts the Company’sPage 153 of 174
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set DEEP-01 Date Issued October 06, 2026 BETP-050 Page 2 of 2 recommended approach of utilizing actual customer interval data gathered during the AMI deployment to inform TVR design so that broad TVR can be launched with a good customer experience one year after AMI meter installation completion, the rate comparison tool would be available for Connecticut customers no later than December 31, 2033.Page 154 of 174
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set DEEP-01 Date Issued October 06, 2026 BETP-051 Page 1 of 1 Date Filed: October 26, 2026 Witness: Jared A. Lawrence Request from: Department of Energy and Environmental Protection Question: (Phased AMI Enabled TVR Availability) Please explain whether the Company evaluated offering AMI-enabled TVR on a voluntary, pilot, or geographic basis to customers whose meters and supporting systems are operational before system-wide deployment is complete. Summarize the principal benefits, risks, and operational considerations identified and explain the basis for the Company’s proposed timing. Response: With respect to TVR, the Company’s proposed AMI Implementation Plan places emphasis on vital objective of deploying the full span of AMI’s technical capabilities, while providing a positive customer experience. To achieve these important objectives, the AMI Implementation Plan ensures there is adequate customer usage data to inform in-depth stakeholder discussions on consensus TVR designs and policies. Customers typically want to maintain control and have options regarding future TVR. Therefore, it is important that customers have access to a robust set of their own AMI interval usage data and a reliable Rate Comparison Tool to make informed decisions about their TVR options. Furthermore, the Company’s AMI Implementation Plan avoids confusion about eligibility (based on whether a customer has received an AMI meter) that could cause frustration and increase the customer service burden during the AMI deployment. By planning to launch TVR broadly for all customers approximately one year after completion of AMI meter deployment, the Company is providing the foundation for thoughtful consensus-based TVR design and the data and tools for customers to make positive decisions. In contrast, an accelerated TVR (partial) launch during AMI meter deployment, while technically feasible, assuming consensus can be reached on the pilot rates, would be a decision that would run the risk of sub-optimally designed rate components, inadequate access to data and tools for participating customers to assess and be confident in their options, and eligibility confusion that could cause frustration with TVR and the broader AMI deployment. Therefore, the Company’s TVR timeline is designed to leverage the optimal path to higher customer satisfaction, higher sustained TVR adoption and, ultimately achievement of the highest benefits that TVR can offer.Page 155 of 174
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set DEEP-01 Date Issued October 06, 2026 BETP-052 Page 1 of 1 Date Filed: October 23, 2026 Witness: Jared A. Lawrence Request from: Department of Energy and Environmental Protection Question: (AMI) Please provide the breakdown of total AMR meters currently nearing the end of their useful lives in Eversource’s Connecticut territory and how many years are remaining in their useful lives? Response: Please refer to the petition filed on October 1, 2026 in Docket No. 17-12-03RE02, Exhibit CLPAMI-3, at page 109, Figure 10 for the requested information. The majority of the existing Eversource AMR and bridge meter population is nearing the end of its useful life. The Company transitioned from manual meter reading to its current AMR drive-by system in the early 2000s, installing over 600,000 meters between 2000 and 2003. As a result, as shown in Figure 10, by 2029, approximately 600,000 meters, nearly 50% of the Company’s meter population, will be over their estimated useful life of 20-years. Figure 10 – Electric Meter Age ProfilePage 156 of 174
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set DEEP-01 Date Issued October 06, 2026 BETP-053 Page 1 of 1 Date Filed: October 26, 2026 Witness: Jared A. Lawrence Request from: Department of Energy and Environmental Protection Question: (AMI) Please provide the estimated cost differences between the existing letters of intent (LOIs) and pricing proposals if implementation proceeds prior to early 2027 versus if implementation proceeds as an outcome from this rate case according to its current time schedule? Response: The Company no longer expects that it can commence implementation “prior to early 2027,” due to delays in regulatory resolutions. Please refer to BETP-053, Attachment 1 CONFIDENTIAL, for information on the letters of intent as it pertains to an outcome on AMI implementation coming at the end of this rate proceeding.Page 157 of 174
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set DEEP-01 Date Issued October 06, 2026 BETP-054 Page 1 of 2 Date Filed: October 27, 2026 Witness: Jared A. Lawrence Request from: Department of Energy and Environmental Protection Question: (AMI) Please provide a detailed breakdown of what subcomponents and their respective costs constitute the $432 million in back office system expenses necessary to begin AMI deployment. Response: The $432 million figure was reviewed within the AMI Stakeholder Review of the BCA Refresh in May 2026, please refer to BETP-054, Attachment 1, for a copy of the slide of the referenced figure. The $432 million in back-office system costs represents the rounded cumulative total of the projected six-year nominal capital and O&M costs for the Meter Data Management System (“MDMS”), Customer Information System (“CIS”), and Load Settlement. The cost estimates were developed using actual costs, ongoing costs, and indicative estimates, as applicable to each system. Please refer to Table 1 below 1 for a cumulative total of all capital and O&M projected costs, and refer to Exhibit CLP-AMI-3, page 16. Table 1 Back Office System 6-Year Nominal 6-Year Nominal Totals Capital O&M* Data $63,000,000 $21,000,000 $74,000,000 System Meter Management (MDMS) Customer Information $212,500,00 System (CIS) Load Settlement $28,800,000 Total $304,300,000 1 Note: these figures are rounded. $102,400,000 $314,900,000 $4,000,000 $127,400,000 $32,800,000 $431,700,000Page 158 of 174
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set DEEP-01 Date Issued October 06, 2026 BETP-054 Page 2 of 2 The following provides a high-level breakdown of the costs by back-office system and the basis for each estimate. For additional detail regarding the underlying cost components, assumptions, and calculation methodology, see Exhibit CLP-AMI-3, Section D.3 – Back-Office Systems. • MDMS – $63.0 million capital and $21.0 million O&M. The estimate is based on actual upfront and ongoing Massachusetts AMI Program costs for implementing and maintaining MDMS, repurposed for Connecticut. These costs include application software, interfaces, procurement and contracting services, system implementation services, consulting services, internal labor, hardware, program management, data conversion, training, and ongoing service and maintenance fees. For a full breakdown of all costs, please refer to pages: 127–132. • CIS – $212.5 million capital and $102.4 million O&M. The estimate is based on indicative Massachusetts CIS replacement and integration costs, modeled for Connecticut, including system integration, software and licensing, data conversion, implementation, and ongoing support. For a full breakdown of all costs, please refer to pages: 135–140. • Load Settlement – $28.8 million capital and $4.0 million O&M. The estimate is based on indicative estimates informed by similar estimates performed for the Massachusetts AMI Program, including labor, hardware, software, procurement and contracting, system integration, data conversion, and ongoing maintenance and licensing. For a full breakdown of all costs, please refer to pages: 142–143.Page 159 of 174
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set DEEP-01 Date Issued October 06, 2026 BETP-055 Page 1 of 1 Date Filed: October 23, 2026 Witness: Jared A. Lawrence Request from: Department of Energy and Environmental Protection Question: (AMI) Please provide greater insight as to why all $432 million of back office system upgrade expenses must be frontloaded before AMI meters can start incrementally realizing benefits for CT? Response: The most significant change that comes about with the implementation of AMI is the magnitude of change relating to data collection, storage, security and analysis. These changes require a major change in backroom information systems. In that regard, the Company’s current legacy CIS and MDMS have only very limited capabilities and would be unable to support most AMI benefits related to the collection, storage, processing and analysis of interval usage data and advanced customer notifications in their current forms. Accordingly, if the Company attempted to deliver some capabilities via the legacy systems, substantial investments be required to essentially “retro-fit” the legacy systems, which would constitute “throw-away” work, as the systems would still need to be replaced during the AMI Implementation Plan in order to enable the full spectrum of AMI benefits (including TVR). Additionally, the AMI Plan includes the design and deployment of the AMI meters and network, which are linked to the back-office systems by a modernized head-end system that collects the meter data from the network access points. For example, one of the components of the AMI Plan is the integration of the new head-end system with the new MDMS. The installation of meters before the new MDMS is deployed would require an additional “throw-away” investment to integrate the new head-end system with the legacy MDMS. Therefore, the Company’s approach is to first modernize the back-office systems prior to AMI meter deployment in order to achieve the most cost-efficient outcome, obviating the need to generate “throw-away” expenses for integrations between new technologies and retiring technologies with limited capabilities.
Text of NECTA Set 6_COMBINED.pdf
Extracted from the file · 22 pages · 43,545 characters
Text of OCC Set 29_COMBINED.pdf
Extracted from the file · 30 pages · 65,312 characters
Text of PURA Set 8_COMBINED.pdf
Extracted from the file · 230 pages · 511,861 characters
As listed on the current system
Corres. 11/06/2026 [26-05-10] (Keegan Werlin LLP) - Discovery Compilation ALLCO Set 13, 16, 18, CIEC Set 7, DEEP Set 1, NECTA Set 6, OCC Set 29, PURA 8