Discovery Compilation ALLCO Set 13, 16, 18, CIEC Set 7, DEEP Set 1, NECTA Set 6, OCC Set 29, PURA 8
Files9
Docket No. 26-05-10 Discovery Compilation November 6 2026.pdf
PDF · 134 KB · 1 pageText searchable
Download Docket No. 26-05-10 Discovery Compilation November 6 2026.pdfRead the text of Docket No. 26-05-10 Discovery Compilation November 6 2026.pdf
ALLCO Set 13_COMBINED.pdf
PDF · 801 KB · 49 pagesText searchable
Download ALLCO Set 13_COMBINED.pdfRead the text of ALLCO Set 13_COMBINED.pdf
ALLCO Set 16_COMBINED.pdf
PDF · 642 KB · 22 pagesText searchable
Download ALLCO Set 16_COMBINED.pdfRead the text of ALLCO Set 16_COMBINED.pdf
ALLCO Set 18_COMBINED.pdf
PDF · 306 KB · 25 pagesText searchable
Download ALLCO Set 18_COMBINED.pdfRead the text of ALLCO Set 18_COMBINED.pdf
CIEC Set 7_COMBINED.pdf
PDF · 230 KB · 7 pagesText searchable
Download CIEC Set 7_COMBINED.pdfRead the text of CIEC Set 7_COMBINED.pdf
DEEP Set 1 (BETP)_COMBINED.pdf
PDF · 1.9 MB · 174 pagesText searchable
Download DEEP Set 1 (BETP)_COMBINED.pdfRead the text of DEEP Set 1 (BETP)_COMBINED.pdf
NECTA Set 6_COMBINED.pdf
PDF · 446 KB · 22 pagesText searchable
Download NECTA Set 6_COMBINED.pdfRead the text of NECTA Set 6_COMBINED.pdf
OCC Set 29_COMBINED.pdf
PDF · 499 KB · 30 pagesText searchable
Download OCC Set 29_COMBINED.pdfRead the text of OCC Set 29_COMBINED.pdf
PURA Set 8_COMBINED.pdf
PDF · 2.5 MB · 230 pagesText searchable
Download PURA Set 8_COMBINED.pdfRead the text of PURA Set 8_COMBINED.pdf
Text of ALLCO Set 18_COMBINED.pdf
Extracted from the file · 25 pages · 65,407 characters
Text of CIEC Set 7_COMBINED.pdf
Extracted from the file · 7 pages · 8,262 characters
Text of DEEP Set 1 (BETP)_COMBINED.pdf
Extracted from the file · 174 pages · 446,641 characters
Page 13 of 22
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set NECTA-06 Date Issued October 14, 2026 NECTA-132 Page 3 of 4 outriggers, brackets, and any other attaching materials necessary to construct the individual pole top framing asset). d. Please refer to NECTA-132, Attachment 2, for an example of how the CU material/cost and charges in the Work Management system (Maximo) flow through and into a work order final as built and the unit of property / retirement unit (RU) in the Company’s Powerplan system. e. Please refer to NECTA-132, Attachment 3, for an example of a 3-phase configuration and NECTA-132, Attachment 4, for an example of a 1-phase configuration for single location installation of a pole top and transfer of facilities onto a newly replaced Frontier pole. These attachments include the work order sketch, material list, work order location detail and capital cost detail with labor, materials and overheads (the information associated with the capital cost detail was derived from the Company’s general ledger system). Prior Referenced Response: i NECTA-131 Question: Refer to NECTA-059, page 1, and NECTA-059, Attachment 1, lines 10–24; NECTA-064 and NECTA-065. To the extent not already provided in response to NECTA-118, provide the following: a. For every retirement-unit entry in NECTA-059, Attachment 1—including INSULATOR, PIN/POST; INSULATOR, STRING; the four “POLE Fully Owned/Jointly Owned” categories; POLE PLATFORM; POLE TOP FRAMING; TRANSFORMER, OVERHEAD < 500 KVA; XFMR, INST OVERHEAD < 500 KVA; and Non-unitized—provide the Company definition, unit of measurement, retirement-unit code, criteria for recording an addition or retirement, and typical equipment/materials, labor, and overhead costs included. b. Produce any retirement-unit dictionary, continuing-property-record manual, plant-accounting instructions, accounting guides, technical publications or other Company documents that define or govern retirement units. c. If a listed retirement-unit description has a different meaning from standard engineering terminology, explain that difference and identify the Eversource document that controls its meaning. NECTA-131 Response: a. As discussed in the response to NECTA-118i, the Company has since reclassified the INSULATOR, PIN/POST; INSULATOR, STRING; TRANSFORMER, OVERHEAD <500 KVA; XFMR, INST OVERHEAD < 500 KVA retirement units to their appropriate Utility Accounts. As described in NECTA130, the Company is providing a revised response to NECTA-059-RV01, Attachment 1 (NECTA-059RV01ii), which will provide updated retirement units. For every retirement unit entry in NECTA-059-RV01, Attachment 1, Account 364310, please find below the Company definition:Page 14 of 22
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set NECTA-06 Date Issued October 14, 2026 NECTA-132 Page 4 of 4 Please refer to NECTA-131, Attachment 1, for a listing of the compatible units (CUs) that comprise the “POLE Fully Owned/Jointly Owned” categories. A listing of CUs that comprise the POLE PLATFORM and POLE TOP FRAMING Retirement Units can be found in NECTA-118, Attachment 1. Unitized assets are recorded in the Continuing Property Records (CPR) at a ‘fully loaded’ cost, including all applicable labor, materials, minor items, and overheads according to the individual work orders’ installation/removal/expense FERC Account mapping allocation, which would calculate the final cost / book value for each unit of measure that is ultimately recognized in the FERC Account 101010 Utility Account. b. Please refer to NECTA-131, Attachment 2, for the Company’s distribution retirement unit manual, NECTA-131, Attachment 3 for the Company’s distribution plant account manual and EOE-060, Attachment 3, APS08 - Capital Versus Expense Criteria, for the Company’s capital vs. expense policy (APS#8). Combined, these documents define and govern the Company’s retirement units. c. There are no listed retirement-unit descriptions that have a different meaning from standard engineering terminology.Page 15 of 22
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set NECTA-06 Date Issued October 14, 2026 NECTA-133 Page 1 of 3 Date Filed: November 03, 2026 Witness: David L. Gladey and Marisa B. Paruta Request from: New England Connectivity and Telecommunications Association Question: Refer to NECTA-059 Attachment 1, line 17 (204 POLE PLATFORM units; $5,070,824), and NECTA064. To the extent not already provided in response to NECTA-118, provide the following: a. Define “POLE PLATFORM” in Eversource’s retirement-unit records, identify what a recorded unit represents, and describe the equipment typically supported (for example, transformers, regulators, other electrical equipment, or common structural elements). State whether any platform is mounted on more than one pole. b. Provide the Company’s engineering drawings, structure/platform standards, specifications, diagrams, bills of material, compatible-unit definitions, construction/maintenance manuals, and available photographs depicting each platform design covered by the retirement unit. c. Provide a listing of the 204 platform units, by type and available identifying code, and identify any portion representing investment in the common pole structure versus equipment-specific support. A complete response will supply supporting records or explain why no allocation can be made. Response: a. Please refer to the Company’s response in NECTA-131 i, subpart a, where the Company provided the definition for “POLE PLATFORM.” Pole platforms are used to provide structural support and a stable mounting surface for voltage regulators on Eversource’s distribution poles. These platforms are used for when their size and weights exceed the capacity of standard mounting provisions. The platform will be mounted utilizing two poles. Please refer to NECTA-133, Attachment 1, for pole platform standards. b. Please refer to the Company’s response in NECTA-118, Attachment 1, where the Company provided a list of the compatible units (CUs) identified individually for “POLE PLATFORM,” which comprise the retirement units in FERC Account 364310. Please also refer to NECTA-133, Attachment 1, for the Company’s standards, bill of materials, and construction and maintenance manuals related to Pole Platforms. NECTA-133, Attachment 1, contains the following: Structure/Platform Standards (with Bill of Material and CUS)Page 16 of 22
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set NECTA-06 Date Issued October 14, 2026 NECTA-133 Page 2 of 3 DTR 16.711 - Platform Mounted Regulator Grounding and Notes DTR 17.046 - 35 kV & Below - Wye-Wye Three-Phase Ste-up/Down Transformer Installation - Platform Mount DTR 20.360 - Design Guide for Platform Mounted Installations DTR 20.361 - 35 kV & Below MGY - Three - Single-Phase DTR 20.371 - 35 kV Delta/UGY & Below - Two or Three Regulator Installation Construction/Maintenance Manuals DSEM 13.101 - Regulator Guide c. Please refer to NECTA-133, Attachment 2, for a listing of the 204 platform units as of December 31, 2025 with asset id, description, and asset location. The Company does not track pole platforms by the type of equipment they support. Prior Referenced Response: i NECTA-131 Question: Refer to NECTA-059, page 1, and NECTA-059, Attachment 1, lines 10–24; NECTA-064 and NECTA-065. To the extent not already provided in response to NECTA-118, provide the following: a. For every retirement-unit entry in NECTA-059, Attachment 1—including INSULATOR, PIN/POST; INSULATOR, STRING; the four “POLE Fully Owned/Jointly Owned” categories; POLE PLATFORM; POLE TOP FRAMING; TRANSFORMER, OVERHEAD < 500 KVA; XFMR, INST OVERHEAD < 500 KVA; and Non-unitized— provide the Company definition, unit of measurement, retirement-unit code, criteria for recording an addition or retirement, and typical equipment/materials, labor, and overhead costs included. b. Produce any retirement-unit dictionary, continuing-property-record manual, plant accounting instructions, accounting guides, technical publications or other Company documents that define or govern retirement units. c. If a listed retirement-unit description has a different meaning from standard engineering terminology, explain that difference and identify the Eversource document that controls its meaning. NECTA-131 Response: a. As discussed in the response to NECTA-118i , the Company has since reclassified the INSULATOR, PIN/POST; INSULATOR, STRING; TRANSFORMER, OVERHEAD < 500 KVA; XFMR, INST OVERHEAD < 500 KVA retirement units to their appropriate Utility Accounts. As described in NECTA-130, the Company is providing a revised response to NECTA-059-RV01, Attachment 1 (NECTA-059-RV01ii), which will provide updated retirement units. For every retirement unit entry in NECTA-059-RV01, Attachment 1, Account 364310, please find below the Company definition:Page 17 of 22
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set NECTA-06 Date Issued October 14, 2026 NECTA-133 Page 3 of 3 Please refer to NECTA-131, Attachment 1, for a listing of the compatible units (CUs) that comprise the “POLE Fully Owned/Jointly Owned” categories. A listing of CUs that comprise the POLE PLATFORM and POLE TOP FRAMING Retirement Units can be found in NECTA-118, Attachment 1. Unitized assets are recorded in the Continuing Property Records (CPR) at a ‘fully loaded’ cost, including all applicable labor, materials, minor items, and overheads according to the individual work orders’ installation/removal/expense FERC Account mapping allocation, which would calculate the final cost / book value for each unit of measure that is ultimately recognized in the FERC Account 101010 Utility Account. b. Please refer to NECTA-131, Attachment 2, for the Company’s distribution retirement unit manual, NECTA-131, Attachment 3 for the Company’s distribution plant account manual and EOE-060, Attachment 3, APS08 - Capital Versus Expense Criteria, for the Company’s capital vs. expense policy (APS#8). Combined, these documents define and govern the Company’s retirement units. c. There are no listed retirement-unit descriptions that have a different meaning from standard engineering terminology.Page 18 of 22
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set NECTA-06 Date Issued October 14, 2026 NECTA-134 Page 1 of 3 Date Filed: October 28, 2026 Witness: Marisa B. Paruta Request from: New England Connectivity and Telecommunications Association Question: Refer to NECTA-059, Attachment 1, lines 11–12 and 19–20; the FERC Account 364 plant instructions in 18 C.F.R. Part 101; and NECTA-064. To the extent not already provided in response to NECTA-118, provide the following: a. Define each of the following retirement units exactly as used by the Company: INSULATOR, PIN/POST; INSULATOR, STRING; TRANSFORMER, OVERHEAD < 500 KVA; and XFMR, INST OVERHEAD < 500 KVA. Specifically define “XFMR” and “INST” and state whether “INST” means installation, instrument, or something else. b. For each retirement unit classification, identify the equipment, fixtures, and installation work captured in Account 364; identify corresponding engineering drawings, specifications, compatible-unit records, bills of material, manuals, and existing photographs c. Explain the accounting basis for recording the specific items in FERC Account 364 rather than Account 365 (Overhead Conductors and Devices) or Account 368 (Line Transformers), as applicable. d. Explain the absence of a reported quantity for three of these categories and reconcile the reported quantities and book costs. Response: a. Please refer to the Company’s response in NECTA-118 i, and NECTA-131 ii. Please refer to the Company’s revised response to NECTA-059-RV01, Attachment 1 (NECTA-059RV01), which will provide updated retirement units in FERC Utility Account 364. b. - d. Please refer to the Company’s response to subpart a. Prior Referenced Response: i NECTA-118 Question: Refer to NECTA-059, Attachment 1. For each of the following retirement-unit categories reported under Utility Account 364310—“INSULATOR, PIN/POST,” “INSULATOR, STRING,” “POLE PLATFORM,” “POLE TOP FRAMING,” “TRANSFORMER, OVERHEAD < 500 KVA,” and “XFMR, INST OVERHEAD < 500 KVA”— please provide the following as of December 31, 2025:Page 19 of 22
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set NECTA-06 Date Issued October 14, 2026 NECTA-134 Page 2 of 3 a. b. Identify and describe each compatible-unit code whose costs are included in the category. For each code, provide its description, physical components, function, quantity, and gross book cost, and reconcile the compatible-unit costs to the category’s book cost in NECTA-059, Attachment 1. Explain any costs that cannot be identified by compatible-unit code. Identify the accumulated depreciation and accumulated deferred income taxes attributable to each category and calculate its net book cost. If these balances are not maintained by retirement-unit category, explain why. NECTA-118 Response: a. During the preparation of the response to NECTA-059i, the Company recognized that the retirement unit categories of” INSULATOR, PIN/POST,” “INSULATOR, STRING,” “TRANSFORMER, OVERHEAD < 500 KVA,” and “XFMR, INST OVERHEAD < 500 KVA” were incorrectly assigned to Utility Account 364310. As such, the Company performed an asset transfer to move those assets which totaled $59,702 to their correct utility accounts. At this time, the only retirement units reported under Utility Account 364310 are as follows: Account 364310 - Poles and Appurtenance Retirement Units at 9/30/26 Non-unitized POLE FO <= 35FT POLE FO > 35FT POLE JO <= 35FT POLE JO > 35FT POLE PLATFORM POLE TOP FRAMING The remaining retirement units are correctly classified per the FERC USofA, 18 CFR Part 101, Electric Plant Instructions for account 364. Please refer to NECTA-118, Attachment 1, for a list of all compatible units which comprise the pole platform and pole top framing retirement units in Account 364310. The gross book cost included in NECTA-059, Attachment 1, includes labor, material, loaders, AFUDC, etc. and therefore cannot be reconciled to the compatible units. b. ii Please refer to NECTA-118, Attachment 2, for the accumulated depreciation, net book value and accumulated deferred income taxes related to Pole Platforms and Pole Top Framing as of December 31, 2025. NECTA-131 Question: Refer to NECTA-059, page 1, and NECTA-059, Attachment 1, lines 10–24; NECTA-064, and NECTA-065. To the extent not already provided in response to NECTA-118, provide the following: a. For every retirement-unit entry in NECTA-059 Attachment 1—including INSULATOR, PIN/POST; INSULATOR, STRING; the four “POLE Fully Owned/Jointly Owned” categories; POLE PLATFORM; POLE TOP FRAMING; TRANSFORMER, OVERHEAD < 500 KVA; XFMR, INST OVERHEAD < 500 KVA; and Non-unitized—provide the Company definition, unit of measurement, retirement-unit code, criteria for recording an addition or retirement, and typical equipment/materials, labor, and overhead costs included.Page 20 of 22
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set NECTA-06 Date Issued October 14, 2026 NECTA-134 Page 3 of 3 b. Produce any retirement-unit dictionary, continuing-property-record manual, plant-accounting instructions, accounting guides, technical publications or other Company documents that define or govern retirement units. c. If a listed retirement-unit description has a different meaning from standard engineering terminology, explain that difference and identify the Eversource document that controls its meaning. NECTA-131 Response: a) As discussed in the response to NECTA-118ii, the Company has since reclassified the INSULATOR, PIN/POST; INSULATOR, STRING; TRANSFORMER, OVERHEAD < 500 KVA; XFMR, INST OVERHEAD < 500 KVA retirement units to their appropriate Utility Accounts. As described in NECTA130, the Company is providing a revised response to NECTA-059-RV01, Attachment 1 (NECTA-059RV01ii), which will provide updated retirement units. For every retirement unit entry in NECTA-059-RV01, Attachment 1, Account 364310, please find below the Company definition: Please refer to NECTA-131, Attachment 1, for a listing of the compatible units (CUs) that comprise the “POLE Fully Owned/Jointly Owned” categories. A listing of CUs that comprise the POLE PLATFORM and POLE TOP FRAMING Retirement Units can be found in NECTA-118, Attachment 1. Unitized assets are recorded in the Continuing Property Records (CPR) at a ‘fully loaded’ cost, including all applicable labor, materials, minor items, and overheads according to the individual work orders’ installation/removal/expense FERC Account mapping allocation, which would calculate the final cost / book value for each unit of measure that is ultimately recognized in the FERC Account 101010 Utility Account. b) Please refer to NECTA-131, Attachment 2, for the Company’s distribution retirement unit manual, NECTA131, Attachment 3, for the Company’s distribution plant account manual and EOE-060, Attachment 3, APS08 - Capital Versus Expense Criteria, for the Company’s capital vs. expense policy (APS#8). Combined, these documents define and govern the Company’s retirement units. c) There are no listed retirement-unit descriptions that have a different meaning from standard engineering terminology.Page 21 of 22
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set NECTA-06 Date Issued October 14, 2026 NECTA-135 Page 1 of 2 Date Filed: October 28, 2026 Witness: Marisa B. Paruta Request from: New England Connectivity and Telecommunications Association Question: Refer to NECTA-059, Attachment 1, lines 23–29; NECTA-062, and NECTA-063. a. For the $63,608,379 of Account 106010 completed construction not classified to specific retirement units, explain whether and to what extent the amount includes pole-top framing, pole platforms, crossarms, braces, brackets, insulators, or transformer-support equipment. b. For the $1,065,950 December 2025 adjusting journal entry associated with Frontier jointly owned pole investment, identify the specific property types or work orders represented, and whether appurtenance costs are included. c. Identify any amounts in Account 106010 as of December 31, 2025 that were later classified to POLE TOP FRAMING, POLE PLATFORM, or the other non-pole retirement units. Provide a reconciliation of subsequent unitizations to the December 2025 balance, where available. Response: a. Similar to what the Company described in response to NECTA-062 i, FERC Account 106010 (Completed Construction not Classified) reflects the amount of non-unitized capital investments placed in service totaling $63,608,379 as of December 31, 2025. These investments are not tracked by retirement unit. Retirement unit quantities are determined through the unitization process once the applicable work order activities are complete and the assets are classified and posted to the Continuing Property Records (CPR). The final book costs of the assets in FERC Account 106010, are moved to FERC Account 101010 (Utility Plant in Service), contemporaneously with the unitization/posting to the CPR. b. Please see the Company’s response to NECTA-129 ii, subpart b. Please also refer to NECTA-135, Attachment 1, for a listing of the affected assets. c. Please refer to NECTA-119, Attachment 2, for the amounts in Account 106010 as of December 31, 2025 that were later classified to POLE TOP FRAMING, POLE PLATFORM, or the other non-pole retirement units.Page 22 of 22
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set NECTA-06 Date Issued October 14, 2026 NECTA-135 Page 2 of 2 Prior Referenced Response i NECTA-062 Question: (FERC Accounts) Provide a spreadsheet of FERC 364 Assets as of December 31, 2025, and that identifies the amount of “non-unitized” investment included in Account 364 for 2025. Identify the number of poles associated with pole investment, classified as non-unitized, and whether those poles were included in the calculation of the usable space and pole count inputs used to calculate the pole rate. NECTA-062 Response: Please refer to the Company’s response NECTA-059i and NECTA-059, Attachment 1, for a summary of FERC Utility Account 364 as of December 31, 2025, that identifies the amount of non-unitized investment included in FERC Account 106010 (Completed Construction not Classified). Poles that are not yet classified and are instead included as part of total non-unitized plant cannot be identified. The only pole counts used in the third-party pole attachment rental rate calculation are found in the following retirement unit (“RU”) categories, which represent the poles that are unitized, classified, and recorded to FERC Account 101010 (Utility Plant in Service): • POLE FO <= 35FT • POLE FO > 35FT • POLE JO <= 35FT • POLE JO > 35FT ii NECTA-129 Question: (Cybersecurity) Please provide the two questionnaires mention on page 35 of Exhibit CLP-AMI2 (Corporate Information Security Risk Assessment Questionnaire (“CISRAQ”) and the due diligence questionnaire (“DDQ”)). In addition, please provide information - including copies of any guidelines, manuals, or standards - on how the Company assess these questionnaires once complete, and ranks or decides if a third party's cybersecurity practices meet Company standards. NECTA-129 Response: The Company is providing the following attachments: • OCC-129, Attachment 1, for the Due Diligence Questionnaire (DDQ) • OCC-129, Attachment 2, for the Corporate Information Security Risk Assessment Questionnaire (CISRAQ) • OCC-129, Attachment 3 CONFIDENTIAL, for the IT Vendor Risk Management Evaluation Process
Text of OCC Set 29_COMBINED.pdf
Extracted from the file · 30 pages · 65,312 characters
Text of PURA Set 8_COMBINED.pdf
Extracted from the file · 230 pages · 511,861 characters
As listed on the current system
Corres. 11/06/2026 [26-05-10] (Keegan Werlin LLP) - Discovery Compilation ALLCO Set 13, 16, 18, CIEC Set 7, DEEP Set 1, NECTA Set 6, OCC Set 29, PURA 8