Discovery Compilation ALLCO Set 13, 16, 18, CIEC Set 7, DEEP Set 1, NECTA Set 6, OCC Set 29, PURA 8
Files9
Docket No. 26-05-10 Discovery Compilation November 6 2026.pdf
PDF · 134 KB · 1 pageText searchable
Download Docket No. 26-05-10 Discovery Compilation November 6 2026.pdfRead the text of Docket No. 26-05-10 Discovery Compilation November 6 2026.pdf
ALLCO Set 13_COMBINED.pdf
PDF · 801 KB · 49 pagesText searchable
Download ALLCO Set 13_COMBINED.pdfRead the text of ALLCO Set 13_COMBINED.pdf
ALLCO Set 16_COMBINED.pdf
PDF · 642 KB · 22 pagesText searchable
Download ALLCO Set 16_COMBINED.pdfRead the text of ALLCO Set 16_COMBINED.pdf
ALLCO Set 18_COMBINED.pdf
PDF · 306 KB · 25 pagesText searchable
Download ALLCO Set 18_COMBINED.pdfRead the text of ALLCO Set 18_COMBINED.pdf
CIEC Set 7_COMBINED.pdf
PDF · 230 KB · 7 pagesText searchable
Download CIEC Set 7_COMBINED.pdfRead the text of CIEC Set 7_COMBINED.pdf
DEEP Set 1 (BETP)_COMBINED.pdf
PDF · 1.9 MB · 174 pagesText searchable
Download DEEP Set 1 (BETP)_COMBINED.pdfRead the text of DEEP Set 1 (BETP)_COMBINED.pdf
NECTA Set 6_COMBINED.pdf
PDF · 446 KB · 22 pagesText searchable
Download NECTA Set 6_COMBINED.pdfRead the text of NECTA Set 6_COMBINED.pdf
OCC Set 29_COMBINED.pdf
PDF · 499 KB · 30 pagesText searchable
Download OCC Set 29_COMBINED.pdfRead the text of OCC Set 29_COMBINED.pdf
PURA Set 8_COMBINED.pdf
PDF · 2.5 MB · 230 pagesText searchable
Download PURA Set 8_COMBINED.pdfRead the text of PURA Set 8_COMBINED.pdf
Text of ALLCO Set 18_COMBINED.pdf
Extracted from the file · 25 pages · 65,407 characters
Text of CIEC Set 7_COMBINED.pdf
Extracted from the file · 7 pages · 8,262 characters
Text of DEEP Set 1 (BETP)_COMBINED.pdf
Extracted from the file · 174 pages · 446,641 characters
Text of NECTA Set 6_COMBINED.pdf
Extracted from the file · 22 pages · 43,545 characters
Text of OCC Set 29_COMBINED.pdf
Extracted from the file · 30 pages · 65,312 characters
Page 220 of 230
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set PURA-08 Date Issued September 25, 2026 UPA-058 Page 1 of 3 Date Filed: October 13, 2026 Witness: Julia Frayer Request from: Public Utilities Regulatory Authority Question: (OM&A PFP AND S-FACTOR) Exhibit CLP-PBR-3, p. 44; Interrog. Resp. OCC-444. LEI explains its use of Akaike Information Criterion (AIC) and Bayesian Information Criterion (BIC) in selecting its preferred econometric benchmarking model specifications. The total-cost and capital-cost models include both the natural log of customers and its squared term, while the OM&A cost model includes only the natural log of customers. a. Beyond the AIC and BIC model-selection criteria discussed by LEI, explain the economic basis for assuming a nonlinear relationship between customer count and total and capital costs but not OM&A costs. b. Re-estimate the preferred OM&A model including the squared natural log of customers and provide the resulting coefficient estimates, model fit statistics, and CL&P benchmarking results. Compare the results with LEI’s preferred OM&A specification. c. Provide any code and associated output used to estimate and compare the alternative specifications, including the calculations of AIC and BIC used in selecting the preferred specifications. Response: a. LEI tested both linear and nonlinear customer-scale specifications during model development. In the OM&A model testing, the squared customer term was not statistically significant and therefore was not retained in the final model specification. By contrast, the squared customer term was statistically significant in the total-cost and capital-cost models and was retained to allow the effect of customer scale to vary across utilities of different sizes. This treatment is also economically reasonable because capital-related costs reflect network infrastructure requirements that may increase non-proportionately with the number of customers served by the utility, whereas OM&A costs are likely to be more linear in their relationship with customer count. b. LEI re-estimated the OM&A model to include the squared natural logarithm of customers. The coefficient estimates, model-fit statistics, and CL&P benchmarking results for both LEI’s preferred OM&A specification and the alternative specification are provided in the table below.Page 221 of 230
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set PURA-08 Date Issued September 25, 2026 UPA-058 Page 2 of 3 Preferred OM&A specification p-value Alternative pspecification with value Customers squared Customers 0.8703 0.000 -0.3114 0.321 Customers squared — — 0.0438 0.000 Labor price 0.9725 0.000 0.9112 0.000 Distribution business share 0.5163 0.000 0.5604 0.000 Time trend -0.0067 0.160 -0.005 0.295 Constant -11.1059 0.000 -2.4813 0.339 R-squared 0.8872 — 0.8896 — Root MSE 0.3164 — 0.3132 — AIC 477 460.19 BIC 500.9 488.87 Variable Statistic / CL&P’s average percentage deviation from 11.90% the applicable benchmark over the 2015–2024 period 15.40% LEI nevertheless continues to prefer its original OM&A specification. The fact that the preferred total-cost and capital-cost models include a nonlinear customer-scale term does not, by itself, imply that the same functional form is appropriate for OM&A costs. In LEI’s judgment, the appropriate specification should reflect the economic characteristics and cost drivers of the particular cost category being modeled. Network- and capacity-related characteristics can lead to discrete capital investments, while customer count provides aPage 222 of 230
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set PURA-08 Date Issued September 25, 2026 UPA-058 Page 3 of 3 reasonable indicator of the scale of recurring operating activities, which tend to change more gradually as the number of customers changes. c. Please refer to UPA-058, Attachment 1, for the existing Stata code and associated output used to evaluate the alternative specifications. AIC and BIC for the preferred and alternative OM&A specifications can be reproduced using Stata’s estat ic and estimates stats commands following estimation of the respective specifications.Page 223 of 230
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set PURA-08 Date Issued September 25, 2026 UPA-059 Page 1 of 3 Date Filed: October 13, 2026 Witness: Julia Frayer Request from: Public Utilities Regulatory Authority Question: (OM&A PFP AND S-FACTOR) Exhibit CLP-PBR-2; Exhibit CLP-PBR-3; Exhibit CLP-PBR-3A Confidential. a. Identify which of the 88 utilities included in LEI’s TFP and benchmarking study underwent changes in their corporate structure (e.g., merged with or acquired another company) during the study period. b. For each of the utilities identified in subpart a, explain how LEI constructed the historical customer series and the criteria used to determine which predecessor or affiliated utilities were combined. Identify all utilities for which customer counts were constructed or adjusted in this manner and explain whether the same treatment was applied to the TFP/PFP and econometric benchmarking analyses. Response: a. LEI identified the utilities listed in Table 1 as utilities for which changes in corporate structure during the study period required historical data to be combined or adjusted to maintain a consistent series over time. In these cases, the historical data of predecessor or subsequently consolidated utilities were included in the customer series of the successor utility (utility included in LEI’s studies). Changes solely in parent or holding-company ownership, or changes in utility name that did not alter the underlying operating utility or customer base represented in the data, did not require historical data to be combined and are not separately identified in the table. The table identifies the final utility included in LEI’s TFP and benchmarking studies, the predecessor or historical utility data incorporated into that utility’s series, and the period for which those historical data were used.Page 224 of 230
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set PURA-08 Date Issued September 25, 2026 UPA-059 Page 2 of 3 Table 1 Final Utility Included in LEI Study Ameren Illinois Company Historical Utility Data Incorporated AmerenIP Central Illinois Light Company Central Illinois Public Service Company The Narragansett Electric Company Blackstone Electric Company Newport Electric Green Mountain Power Corporation Central Vermont Public Service Corporation Versant Power (previously d/b/a Bangor Hydro Electric Company) Maine Public Service Company FirstEnergy Pennsylvania Electric Company Metropolitan Edison Company Pennsylvania Electric Company Pennsylvania Power Company West Penn Power Company NSTAR Electric Cambridge Electric Light Company Commonwealth Electric Company Western Massachusetts Electric Company b. LEI constructed the historical series using utility-level data from the sources identified in the TFP Report, including FERC Form 1 data compiled by S&P Global Market Intelligence and EIA Form 861 data. For utilities affected by mergers, acquisitions, or consolidations, LEI mapped predecessor utilities to the successor utility included in the study. For periods prior to a merger or consolidation, LEI used the separately reported historical data of predecessor utilities that subsequently became part of the successor utility, to the extent those data were not already reflected in the successor utility’s reported historical series. Where more than one predecessor utility was combined into a successor utility, LEI combined the underlying utility-level data for the applicable historical years, again only to the extent those data were not already captured in the successor utility’s reported series. Once the successor utility was reported as a single entity by the data provider, LEI used the successor utility’s reported data and no longer separately included the predecessor utility data. This treatment was appliedPage 225 of 230
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set PURA-08 Date Issued September 25, 2026 UPA-059 Page 3 of 3 consistently to the underlying data used in the TFP/PFP and econometric benchmarking analyses.Page 226 of 230
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set PURA-08 Date Issued September 25, 2026 UPA-060 Page 1 of 1 Date Filed: October 13, 2026 Witness: Julia Frayer Request from: Public Utilities Regulatory Authority Question: (OM&A PFP AND S-FACTOR) Exhibit CLP-PBR-3 Provide the OM&A and total-cost benchmarking results with Account 908 included and compare CL&P’s resulting benchmark performance with the preferred specifications excluding Account 908. Response: Please refer to UPA 060, Attachment 1, for the requested information. When Account 908 is included for all utilities for all years in LEI’s benchmarking analysis, CL&P’s OM&A costs averaged approximately 23.6% above benchmark, while its total costs averaged approximately 4.9% above benchmark, over the 2015–2024 period. By comparison, under LEI’s preferred specifications excluding Account 908, CL&P’s OM&A costs averaged approximately 11.9% above benchmark, while its total costs averaged approximately 2.3% below benchmark over the same period. Thus, including Account 908 results in less favorable benchmark performance for CL&P: wherein the OM&A cost deviation increases by approximately 11.7 percentage points, and the total-cost deviation increases by approximately 7.2 percentage points. As explained in Exhibit CLP-PBR-3, LEI excluded Account 908 (Customer Assistance Expenses) because it primarily includes expenditures associated with customer assistance and public policy programs, such as energy efficiency, demand-side management, low-income assistance, and customer education. These expenditures are largely driven by legislative and regulatory requirements and can vary significantly across jurisdictions based on differences in state policy objectives, rather than differences in the operating efficiency, which is the ultimate objective of the benchmarking analysis. Therefore, LEI’s professional opinion is that excluding Account 908 is a more valid and reliable approach because it improves comparability across utilities and focuses the benchmarking analysis on costs more directly associated with the provision of electric distribution service.Page 227 of 230
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set PURA-08 Date Issued September 25, 2026 UPA-061 Page 1 of 4 Date Filed: October 13, 2026 Witness: Julia Frayer, Matthew Nelson and Michael Goldman Request from: Public Utilities Regulatory Authority Question: (OM&A PFP AND S-FACTOR) Exhibit CLP-PBR-3; Interrog. Resps. OCC-431, OCC-443, OCC539, OCC-543. LEI proposes a 0.3% annual Consumer Dividend (S-factor). Assuming CL&P achieves the 0.3% annual Consumer Dividend in each year of the four-year MRP: a. Quantify the reduction in CL&P OM&A that would result over the four-year MRP relative to the revenue-cap trajectory without the Consumer Dividend; b. Compare that reduction to the efficiency gap identified for CL&P in LEI’s benchmarking analysis, including under each benchmarking method relied upon by LEI; and Quantify the percentage of the identified benchmarking/efficiency gap that would be closed by the end of the four-year MRP. Response: a. As noted in Exhibit CLP-PBR-1 at 58, benchmarking results should not be translated directly into a Consumer Dividend or S Factor. The difference between a utility’s actual costs and its benchmarked costs represents an estimate of relative cost performance at a point in time; it does not indicate the extent to which those differences can reasonably or sustainably be eliminated over the term of a PBR plan. Rather, the Consumer Dividend represents a “sharing” of benefits with customers for the duration of the PBMRP by reducing the amount of revenue support that would otherwise be provided to the Company in the absence of the Consumer Dividend (see Exhibit CLP-PBR-1 at 64). Under the Company’s proposal, the Consumer Dividend will never be less than 0.3 percent, meaning it can only reduce customer rates by no less than 0.3% as part of the I-X-S calculation. However, the Consumer Dividend does not reflect a direct quantification of OM&A savings that will (or won’t) be realized during each year of the PBMRP, such that it’s not possible to quantify the reduction in OM&A that would result over the four-year MRP relative to the revenue cap trajectory without the Consumer Dividend. Rather, the Consumer Dividend provides for a sharing of savings with customers for the duration of the PBMRP regardless of actual OM&A savings realized during the plan. Having said that, LEI presents the following analysis in response to this question. LEI’s benchmarking analysis evaluates CL&P’s relative cost performance using both unitcost and econometric benchmarking. As discussed in Exhibit CLP-PBR-3, unit-costPage 228 of 230
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set PURA-08 Date Issued September 25, 2026 UPA-061 Page 2 of 4 benchmarking provides a high-level comparison of observed costs per customer across utilities, but does not account for differences in business drivers that may cause one EDC to have higher or lower unit costs, including input prices, network configuration, scale, customer characteristics, and economies of scope. LEI therefore also relies on econometric benchmarking, which controls for these factors and provides a more comprehensive assessment of relative cost performance. As an illustrative reference point, Figure 1 below compares CL&P’s OM&A cost per customer in 2022-2024 with selected points in the national and Northeast peer distributions, using the unit cost benchmarking analysis. The results demonstrate that the apparent magnitude of CL&P's cost difference varies materially depending upon the comparator selected. For example, in 2024, CL&P’s OM&A cost per customer was approximately 397%, or $134.2/customer, above the lowest-cost utility’s OM&A cost per customer in the 88-utility national sample; 49%, or $55.4/customer, above the national median; and 39%, or $46.9/customer, above the national average. Within the 22-utility Northeast sample, CL&P was approximately 79%, or $74.2/customer, above the lowest-cost utility‘s OM&A cost per customer; 0.2%, or $0.4/customer, below the median; and 2%, or $3.5/customer, below the average. Similar variation is evident in 2022 and 2023. These differences should not be interpreted as estimates of the amount by which CL&P can reduce its costs. In particular, comparison with the lowest-cost or highest-ranked utility does not establish that CL&P could attain that utility's cost level, because utilities differ in operating characteristics and cost drivers. Figure 1: CL&P OM&A cost deviation from industry and Northeast comparatorsPage 229 of 230
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set PURA-08 Date Issued September 25, 2026 UPA-061 Page 3 of 4 Note: A lower rank indicates relatively lower OM&A costs per customer. Accordingly, Rank #1 represents the utility with the lowest OM&A cost per customer. LEI also performed a hypothetical test still using the unit cost benchmarking to illustrate how CL&P’s historical national OM&A cost-per-customer ranking would change if CL&P’s OM&A cost per customer were reduced by assumed percentages of 10%, 25%, or 50%, while holding the historical costs of all other utilities unchanged. See Figure 2 below. The table shows how progressively larger assumed reductions in CL&P’s OM&A cost per customer would affect its relative ranking in each of the three historical years shown. This is a hypothetical ranking exercise only; it is not a benchmarking analysis. Benchmarking is conducted on an industry-wide basis using the observed costs and characteristics of all utilities in each year. Accordingly, reducing only CL&P’s historical cost while leaving all other utilities unchanged does not represent how CL&P would necessarily rank in a future period, because other utilities’ costs and operating conditions would also change over time. Figure 2: Impact of hypothetical cost reductions on CL&P’s OM&A/customer ranking (National) Note: A lower rank indicates relatively lower OM&A costs per customer. LEI’s econometric analysis further demonstrates why a simple unit-cost gap should not be treated as a direct measure of inefficiency. After controlling for relevant business drivers, CL&P’s OM&A costs averaged approximately 11.9% above the model-predicted benchmark over 2015–2024 and approximately 16.4% above benchmark over 2021–2024. At the same time, CL&P’s capital costs remained below benchmark and its total costs averaged approximately 2.3% below benchmark over 2015–2024 and 3.1% below benchmark over 2021–2024. Thus, while the benchmarking analysis indicates opportunities for continued OM&A efficiency improvements, it also shows that CL&P’s overall cost performance is more favorable than the simple unit cost benchmarking may otherwise imply, after controlling for relevant cost drivers.
As listed on the current system
Corres. 11/06/2026 [26-05-10] (Keegan Werlin LLP) - Discovery Compilation ALLCO Set 13, 16, 18, CIEC Set 7, DEEP Set 1, NECTA Set 6, OCC Set 29, PURA 8