Interrogatory responses
Answers to questions 27
Files12
ALLCO-027.pdf
PDF · 150 KB · 2 pagesText searchable
ALLCO-027 Attachment 1 REDACTED (KW Proposal).pdf
PDF · 1.3 MB · 5 pagesText searchable
Download ALLCO-027 Attachment 1 REDACTED (KW Proposal).pdfRead the text of ALLCO-027 Attachment 1 REDACTED (KW Proposal).pdf
ALLCO-027 Attachment 2 REDACTED (KW Acceptance Letter).pdf
PDF · 772 KB · 1 pageText searchable
Download ALLCO-027 Attachment 2 REDACTED (KW Acceptance Letter).pdfRead the text of ALLCO-027 Attachment 2 REDACTED (KW Acceptance Letter).pdf
ALLCO-027 Attachment 3.pdf
PDF · 108 KB · 1 pageText searchable
Download ALLCO-027 Attachment 3.pdfRead the text of ALLCO-027 Attachment 3.pdf
ALLCO-027 Attachment 3.xlsx
Excel · 20 KBText searchable
Download ALLCO-027 Attachment 3.xlsxRead the text of ALLCO-027 Attachment 3.xlsx
ALLCO-027 Attachment 6 REDACTED (CL&P RFP).pdf
PDF · 1.1 MB · 5 pagesText searchable
Download ALLCO-027 Attachment 6 REDACTED (CL&P RFP).pdfRead the text of ALLCO-027 Attachment 6 REDACTED (CL&P RFP).pdf
ALLCO-027 Attachment 8 REDACTED.pdf
PDF · 1.7 MB · 2 pagesText searchable
Download ALLCO-027 Attachment 8 REDACTED.pdfRead the text of ALLCO-027 Attachment 8 REDACTED.pdf
ALLCO-027 Attachment 9.pdf
PDF · 94 KB · 1 pageText searchable
Download ALLCO-027 Attachment 9.pdfRead the text of ALLCO-027 Attachment 9.pdf
ALLCO-027 Attachment 9.xlsx
Excel · 20 KBText searchable
Download ALLCO-027 Attachment 9.xlsxRead the text of ALLCO-027 Attachment 9.xlsx
ALLCO-027 Attachment 4 REDACTED.pdf
PDF · 9.1 MB · 409 pagesText searchable
Download ALLCO-027 Attachment 4 REDACTED.pdfRead the text of ALLCO-027 Attachment 4 REDACTED.pdf
ALLCO-027 Attachment 5 REDACTED.pdf
PDF · 19 MB · 238 pagesText searchable
Download ALLCO-027 Attachment 5 REDACTED.pdfRead the text of ALLCO-027 Attachment 5 REDACTED.pdf
ALLCO-027 Attachment 7 REDACTED (1).pdf
PDF · 5.6 MB · 41 pagesText searchable
Download ALLCO-027 Attachment 7 REDACTED (1).pdfRead the text of ALLCO-027 Attachment 7 REDACTED (1).pdf
Text of ALLCO-027 Attachment 3.pdf
Extracted from the file · 1 page · 576 characters
Text of ALLCO-027 Attachment 3.xlsx
Sheet names, column headings and text cells; numbers left out
Text of ALLCO-027 Attachment 6 REDACTED (CL&P RFP).pdf
Extracted from the file · 5 pages · 7,247 characters
Text of ALLCO-027 Attachment 8 REDACTED.pdf
Extracted from the file · 2 pages · 514 characters
Text of ALLCO-027 Attachment 9.pdf
Extracted from the file · 1 page · 741 characters
Text of ALLCO-027 Attachment 9.xlsx
Sheet names, column headings and text cells; numbers left out
Text of ALLCO-027 Attachment 4 REDACTED.pdf
Extracted from the file · 409 pages · 1,259,015 characters
Page 11 of 238
The Connecticut Light and Power Company d/b/a Eversource Energy REDACTED Docket No. 26-05-10 Date Issued September 2, 2026 ALLCO-027 Attachment 5 REDACTED Page 11 of 238 Post-filing Support Tasks Amparo Nieto, with support from her team, will perform the following expert witness role tasks: 5.4. • • • • • Support Direct Pre-filed Testimony (responses to information requests). Preparation of Rebuttal testimony, as needed. Assist in the Interrogation of Testimony as submitted by other parties. Attend Hearings for Cross Examination. Respond to In-Hearing Record Requests. • Assist in Drafting of Legal Brief submitted by the Commission. Project Timeline CRA is available to begin work as soon as early February. We anticipate that a complete draft ACOS and MCS studies will be ready by the fourth week of March, with final models of both studies completed during the week of April 20, subject to receiving all key required inputs. CRA will work with the Company to review available data expeditiously and ensure an efficient process. CRA’s team will meet and collaborate with the Company in the Rate Analysis task to guide final class revenue decisions, TOU period analysis and innovative rate options. This work can be expected to be completed by the week of April 27 well in advance of the rate case filing on June 2. Figure 2 illustrates the anticipated timeline for the pre-filing tasks. This timeline can be discussed at the kick of meeting, and CRA’s team can adapt to Company’s requirements as needed. The envisioned timeline for milestones includes potential need for updates to the draft studies, e.g., should the Company need to revise initial revenue requirement. Figure 1. Project Timeline for Pre-Filing Phase Cover Agreement – CL&P ACOS and MCS CRA International Inc. Page 11 Eversource ConfidentialPage 12 of 238
The Connecticut Light and Power Company d/b/a Eversource Energy REDACTED Docket No. 26-05-10 Date Issued September 2, 2026 ALLCO-027 Attachment 5 REDACTED Page 12 of 238 6. TECHNICAL APPROACH OF THE MARGINAL COST OF SERVICE STUDY 6.1. The Role of a Marginal Cost Study The goal of a MCOS is to obtain a forward-looking view of the typical cost associated with a unit of incremental electricity usage over the study period, so that it is useful to set cost reflective charges in rates. We will discuss the details of the various alternatives at the onset of the project and will explain the rationale of our proposed approach. Progressing towards economically efficient rates ultimately is largely grounded on offering tariffs that allow the Company to more closely reflect the utility’s forward-looking cost of meeting incremental demand, i.e., marginal cost-based price signals. Such signals represent the economic impact of incremental customer loads, or cost savings from decremental peak load on the grid. Customers are ultimately encouraged to make efficient usage and investment decisions if the rate components are more aligned with appropriate relationships between fixed and variable cost of service, as well as by appropriate seasonality and cost-reflective time of use charges. The study will estimate timedifferentiated, system-wide average distribution value of load reductions, therefore will be helpful to inform the direction of reforms that would be suitable for Eversource’s distribution rate designs, in terms of rate structure, and rebalancing of revenue requirement by rate component, and improvements in Time of Use (TOU) rates. These rates are applicable to determine applicable rates to all retail customers, including those with customer-sited distributed generation (DG), and other distributed energy resources (DERs). It also provides information on the going forward marginal upstream distribution cost of meeting incremental peak load, which may be driven by addition of customers or incremental load by existing customers, such as those related to electric vehicles, or electric heat pump loads. Cover Agreement – CL&P ACOS and MCS CRA International Inc. Page 12 Eversource ConfidentialPage 13 of 238
The Connecticut Light and Power Company d/b/a Eversource Energy REDACTED Docket No. 26-05-10 Date Issued September 2, 2026 ALLCO-027 Attachment 5 REDACTED Page 13 of 238 6.2. Use of engineering approach In the context of the utility distribution service, a forward-looking marginal cost analysis requires evaluating the utility’s response to an anticipated change in the use of the distribution system in a given hour, as well as incremental unit costs driven by changes in customer connections and customer service requirements. Thus, best practice marginal costing requires engineering-based methods that are consistent with system planning, i.e., the Company’s prevailing capital plan and design standards. We will review the expected peak load growth and meet with representatives of the planning group as well as potentially the load forecasting group to make sure that we are consistent in assumptions and inputs into the model. In the MCS study we will identify the three main elements of distribution service based on the respective cost drivers: Distribution costs that vary with expected growth in near-time peak load (substations and trunkline feeders) Distribution facility costs that vary with the long-term, maximum design demand of the customers expected to served (primary lines, secondary transformer, and secondary lines) Costs that are specific to the customer (meter and service drop, meter-reading and billing, customer accounting and customer services). 6.3. Approach to Estimate Costs 6.3.1. Marginal Distribution Substation and Primary Feeder Costs Ideally, the marginal study will capture the expected investment in distribution upstream station, distribution substation and trunkline primary feeder investment per kW of load growth over the study period. We will review the latest capital expansion plan, size and location of the distribution projects and identify the nature of the projects in consultation with the Company’s distribution planners to identify capital expansion that is mainly related to growth. We will compute the marginal cost of distribution stations, by dividing the identified peak-load related station investments by the station project’s added capacity. We will verify with the Company what the current reliability standards at each voltage level are. The distribution substation and primary feeder marginal costs, both determined as an average of capacityexpansion areas and as a system-wide average marginal cost estimate, will be annualized using an economic carrying charge (ECC) and will incorporate marginal O&M expenses and loading factors. All marginal cost calculations require developing economic carrying charges for annualizing investment. The study also requires estimating operating and maintenance expenses for each type of marginal plant, estimating marginal corporate overheads such as general plant and administrative and general expenses, estimating losses to convert to costs at the meters of customers, and identifying loaders for marginal working capital. Marginal costs will be summarized by pricing periods suitable for TOU tariffs. Cover Agreement – CL&P ACOS and MCS CRA International Inc. Page 13 Eversource ConfidentialPage 14 of 238
The Connecticut Light and Power Company d/b/a Eversource Energy REDACTED Docket No. 26-05-10 Date Issued September 2, 2026 ALLCO-027 Attachment 5 REDACTED Page 14 of 238 6.3.2. Marginal Local Distribution Facilities Costs Another component of the distribution marginal cost study is the cost associated with connecting a new customer to the grid. The costs involved in distribution connections may involve a new line transformer, investment in primary lines, and/or secondary lines. These local facilities must be sized sufficiently large to meet the expected maximum demand of the customers that will be connected to them over their service life. The costs vary depending on type of area served, including customer density (urban, rural), and type of customer use (industrial versus primarily residential). Single versus three-phase connections also determine the specific design demand. We will rely on the Companies’ work order system to review the range of historical line extension jobs to obtain a range of connection scenarios (single vs poly-phase, residential subdivisions vs. commercial, etc.) and the costs associated with the connection. To the extent that some of the scenarios are not included in recent history, we would request calculations for specific applications or scenarios from distribution engineers, net of customer contributions. 6.3.3. Marginal Customer Costs We will review the current installed cost of a typical meter and service drop by rate class and add an estimate of marginal meter O&M costs, based on recent meter O&M expenses and assuming that the meter O&M is proportional to the cost of the meter in order to estimate meter O&M differentiated by rate class. Customer accounts expenses, composed mainly of meter-reading and billing expenses, and customer service and informational expenses, are function of the number of customers on the system and may reflect relative cost differences based on requirements by class. The MCOS study will apply weighting factors developed for customer accounts and customer service and informational expenses by class excluding any cost associated with energy efficiency programs and apply to recent per-customer expense to develop future marginal expense of these set of accounts. 6.3.4. Streetlighting The MCS study will incorporate marginal cost in today’s dollars, of system-related service consisting of customer and demand components that apply to any fixture connected to the Company’s distribution system, regardless of ownership. The customer component applies monthly to each fixture connected to the Company’s system, while the demand component is a uniform rate per watt that applies to the rated wattage of each fixture under either rate schedule. These two charges are combined to form the total charge per fixture each month for the system component of distribution service. The components of total installed cost of each type of equipment will be annualized using the appropriate economic carrying charge. 6.1. Other important elements of the MCS Study This section provides additional details of the proposed approach for the MCS study. 6.1.1. Timeframe Factors that affect the robustness and applicability of the results for rate design include the time frame considered for the study. To be useful for efficient price signals in rates, the chosen timeframe must reasonably capture the period the rates are going to be in effect. Our initial recommendation is to use a Cover Agreement – CL&P ACOS and MCS CRA International Inc. Page 14 Eversource ConfidentialPage 15 of 238
The Connecticut Light and Power Company d/b/a Eversource Energy REDACTED Docket No. 26-05-10 Date Issued September 2, 2026 ALLCO-027 Attachment 5 REDACTED Page 15 of 238 timeframe that is consistent with the Company’s distribution capital expansion plan. Going beyond the expansion plan to evaluate marginal costs may limit the precision of the marginal cost estimates. 6.1.2. Locational granularity The study will look at marginal costs by distribution substation area in the capital plan and in additionally, we will offer to review particular feeders of other high growth areas. Marginal investment in a given substation and trunkline feeder divided by project capacity added, can be restated as dollar per peak load growth that is driving the need for the investment. 6.1.3. Sensitivity scenarios Time of Use rates consider peak-related marginal costs over several years, and might need to be revisited as solar DG and EV use increase over time. We propose to undertake a marginal cost study sensitivity that would review how the distribution peak load could be expected to increase from electrification goals in the upcoming five years and how it would affect the capacity of the system but for the existence of the improved and more granular seasonality in TOU distribution rates. 6.2. Calculation of Marginal Costs Revenues Our MCOSS model will allow computing marginal cost revenues by customer class. This step will be important in using marginal costs as a floor for rate design and special contract design. We will also work with the Company to discuss how these results can be used as an input for decisions on class revenue requirements along with ACOS study results. 6.4. Deliverables The deliverables of the MCS study will be: • • • • A draft and Final MCOS Model, which will provide a summary of marginal unit cost by cost component and TOD to compare with current rates A presentation with the main findings of the MCOS Study and application to rate design A presentation of the results of the hourly probability of peak that assigns annualized cost to different hourly periods by daytype and month, informing the decisions on appropriate TOU periods. Pre-filed direct testimony with an overview of the overall MCOS methods and results, cost of service principles and the advantages of the chosen approaches over other methods The MCOS studies will be flexible and able to fully support any service class re-alignment or rate restructuring that the Companies propose. We will review the results with the Company via a PowerPoint presentation to go over the main findings and clarify any questions. We will provide complete documentation of all inputs and sources to enable the Company’s staff to update the studies in the future. We note that the model should be considered proprietary and therefore the Company will be able to use it for rate case, but it may only be shared with rate case intervenors if they agreed to the appropriate protective Orders of the rate case. Cover Agreement – CL&P ACOS and MCS CRA International Inc. Page 15 Eversource ConfidentialPage 16 of 238
The Connecticut Light and Power Company d/b/a Eversource Energy REDACTED Docket No. 26-05-10 Date Issued September 2, 2026 ALLCO-027 Attachment 5 REDACTED Page 16 of 238 7. TECHNICAL APPROACH FOR THE ALLOCATED COST OF SERVICE STUDY 7.1. PURA Requirements In PURA Docket No. 17-10-46, Eversource/CL&P did use the Minimum System methodology in its Cost of Service Study (COSS), and PURA explicitly accepted continued use of that approach to guide revenue allocation and class rate design targets. 7.2. Approach CRA will develop an overview of the ACOSS with methods supported by the Authority and aligned with best practice theoretical foundation, Work will involve classification and functionalization of costs in accordance with how they are incurred (demand- or customer related); development and assignment of cost allocators according to their function and classification; allocation of costs to each rate class; potential allocation of costs on a time varying basis; and calculation of the revenue “excess” or “deficiency” by rate class relative to the revenue requirement. ACOS studies are used as a guide in the Company’s revenue allocation, by allocating costs (test-year plant and expenses) to each customer class according to the appropriate functionalization, classification, and allocation methods. The ACOS study allows establishing appropriate class cost responsibility, and inform changes in overall rate revenues that are required to ensure that each class Rate of Return (“ROR”) gets closer to the average Company’s proposed ROR. This means that classes with below system average rates of return (as calculated within the COSS) may need to be allocated a greater than average percentage distribution increase, while those classes with above system average rates of return would receive a lower than average percentage increase. CRA will run a “proforma” ACOS study (based on the per books study, but adjusted for known and measurable changes, and other adjustments, including the revenue requirement. Earlier in the process, we will review how the proposed revenue requirement that the Company will prepare for the test year is factored into the proforma version of the ACOS study. The ACOS model will include the classification of distribution costs between directly assigned, demand, customer and revenue-related, and the allocation of embedded costs among its rate classes. At the initial stage we will include any preliminary information available on all inputs in accordance with total company cost of service for the test year. Final ACOS result sheets will show: • A summary of the current revenue, operating expense and earned ROR relative to the allocated Proforma rate base for each rate class; • A summary of the calculated revenue excess or deficiency of each rate class when applying the proposed ROR on a levelized basis across all rate classes. • A breakdown by rate class of the proposed Rate Year 1 revenue requirement into customer and demand related components; and a calculation of corresponding unit costs. • Back up worksheets will detail the calculation of costs by component represented in the summary pages of the ACOS model. Specific Summary pages are listed in “ACOS workpapers section”. Cover Agreement – CL&P ACOS and MCS CRA International Inc. Page 16 Eversource ConfidentialPage 17 of 238
The Connecticut Light and Power Company d/b/a Eversource Energy REDACTED Docket No. 26-05-10 Date Issued September 2, 2026 ALLCO-027 Attachment 5 REDACTED Page 17 of 238 • A comparison of Current versus Proposed Rate of Return by class. 7.2.1. Steps in ACOS approach The elements of ACOS study approach that we expect to review and discuss with the Company in the early stage of modelling will include the following aspects: The classification of costs, previously functionalized in the Company’s revenue requirement model. CRA will conduct the breakdown between customer and demand-related component of the distribution primary and secondary system using the results of the Minimum System Approach for accounts. CRA will review any relevant worksheets or exhibits from the latest ACOS study in particular the classification step and the allocation factors for the test year and discuss any potential enhancements in the method for the Company’s consideration. The proposed allocation approach will include review of the availability of the data necessary and guidance as to the development of required allocation factors, with criteria indicated below: • how primary and secondary costs will be allocated to customers depending on their voltage level of service, the street lighting cost allocation method, and the underlying assumptions to develop allocators for each test year (actual and pro-forma). • The method to assign line transformer costs to customers may include a combination of weighted customer count, for the customer-related component, and the demand-related costs • The basis and method to produce weighted customer counts to allocate services and meter costs. 7.2.2. Minimum system study The MS has a long history of development and application across the country, and the Authority ordered the Company to continue using it in its decision at the last rate case. We have assumed that the Company will prepare the Minimum System Study, with our support and feedback. CRA will review the input data into the study, and in particular: • The choice of minimum size by relevant account • The separation between primary and secondary, overhead and underground as feasible • The application of Handy-Whitman index • The method to calculate population for each feeder and transformer type CRA will review the inputs and provide any feedback if needed to make the analysis more robust or objective. Once results are available, CRA will meet with the Company to review the results, alignment with prior rate case study and what drives the difference. 7.3. Deliverables The main deliverables for the ACOS study will include: 1. ACOS Model and external back-up files. Sensitivity will be incorporated into the ACOS model so that the Company can test different allocators (NCP, CP, INCP, Probability of Peak factors, others.) Cover Agreement – CL&P ACOS and MCS CRA International Inc. Page 17 Eversource ConfidentialPage 18 of 238
The Connecticut Light and Power Company d/b/a Eversource Energy REDACTED Docket No. 26-05-10 Date Issued September 2, 2026 ALLCO-027 Attachment 5 REDACTED Page 18 of 238 2. Periodic calls and brief notes with progress report on the ACOS model and findings, discussions on classification and cost allocation approaches, and modifications as necessary for a more robust ACOS approach. 3. Exhibits with calculations of class revenue requirements supporting the Company’s proposals on revenue targets. 4. Exhibits with calculations supporting the Company’s proposed distribution rate designs. 5. Pre-filed direct testimony (draft and final) explaining ACOS methods and results, recommendations in revenue requirement allocation by class and distribution rate designs. We will produce a draft and a final ACOS study, and will be sure that the model is thoroughly checked and that all assumptions used are transparent and discussed with the Company. 7.1. Alignment between ACOS and MCOS Studies CRA will work with the Company’s Rates team to make sure that the assumptions used for the ACOS study are appropriate and consistent with assumptions used for the MCOS study. The ACOS study includes some information that is also used in the development of marginal cost estimates, including test-year installed cost of distribution equipment, such as transformers, meters, service drops; test year customer class allocations of customer service and information expenses, as well as customer account expenses (which were an input to the calculation of customer weighting factors in the MCOS); and peak load data by region. The typical local distribution configurations used in the MCOS study will be helpful to the development of factors employed in the minimum size methodology in the ACOS study. 8. RATE DESIGN APPROACH 8.1. Overview of Rate Design Considerations CRA will develop robust and defensible cost allocation and marginal cost studies that will jointly inform the Company on (a) appropriate class cost responsibility based on cost causation as per the ACOS and on (b) the needed revenue recovery from individual rate components, i.e., potentially applying differentiated increases to customer charges, vs. volumetric charges, as well as appropriate adjustments to demand charges for those classes that are demand-metered using largely the results of the MCOS analysis and ensuring the right provision of incentives. Innovative rate structures, which introduce more cost-reflective time-differentiation, as well as rates that reflect a more appropriate allocation of costs to the various components in alignment with cost causation, have a higher likelihood of providing customers with the right economic incentives, compared to legacy rates, that no longer reflect the underlying marginal cost of service across hours of the day, and/or seasons, or components. We will complete a review of existing rates and discuss modifications to each of the rate components as informed by the study results. Our review will include an evaluation of the appropriateness of the Company’s customer rate designs, including whether the rates reflect price signals consistent with marginal costs. CRA will review these and other areas and provide recommendations based on study results and rate design expertise. We will review including appropriate TOU periods and seasons, potential to streamline any Cover Agreement – CL&P ACOS and MCS CRA International Inc. Page 18 Eversource ConfidentialPage 19 of 238
The Connecticut Light and Power Company d/b/a Eversource Energy REDACTED Docket No. 26-05-10 Date Issued September 2, 2026 ALLCO-027 Attachment 5 REDACTED Page 19 of 238 existing block rates for commercial customers, appropriate rate structure (e.g., variable volumetric rates only vs combination of variable and demand charges; introduction of subscription fees). We will complete a review of existing rates and discuss modifications to each of the rate components as informed by the study results. Our review will include an evaluation of the appropriateness of the Company’s customer rate designs, including whether the rates reflect price signals consistent with marginal costs results. CRA will work with the Company to make sure that the proposed rate designs consider efficiency, equity, customer choice, and evaluate any need for a gradual transition to the target revenue and t the rate structures based on best principles. Additional rate options that can be incorporated in the evaluation will include curtailable or interruptible rates structures; electric vehicle charging rates for home charging, including potential TOU rates and Critical Peak Pricing; and other optional rate structures that support affordability. We will develop a detailed list of possible alternative rate designs that may be appropriate for the Company to pursue. This will include examining whether the chosen rate design alternatives may or may not be appropriate to implement at this time, given bill impacts or billing/metering constraints. Once we have identified rate designs with the Company, we will discuss implementation matters and a review of experience in other jurisdictions. Implementation costs of new time of use rates should be measured against avoided costs associated with customers shifting usage away from the peak period. We will also review the pros and cons of mandatory vs. optional rates implementation. For TOU rates to fully reflect time-differentiated price signals that lead to efficient usage decisions, the rates must aim to properly reflect the pattern of hourly marginal costs of service across times of the day and within each season. We will suggest optional TOU rates for the Companies to consider and help decide on the choice of periods and seasons balancing goals of efficiency and customer understanding. The hourly marginal distribution station and trunkline feeder costs that result from the marginal distribution cost study need to be averaged by the appropriate time of use periods in each season. With TOU rates customers can manage their bills by shifting flexible load to hours that do not drive a meaningful need of capacity expansion, compared to what the current non-TOU kWh charges would incentivize, leading to more customer satisfaction. 8.2. Fixed vs. Volumetric Rates and Demand Charges In preserving affordability through rate design, an important step is to identify the impact of increased usage on customer bills, and particularly, on the potential benefits to customers of reducing reliance on fixed cost recovery through volumetric charges to lower that effect. The marginal unit cost estimates by component help identify rate structures. In formulating any residential rate design recommendations, we will keep in mind the Authority’s decision regarding the maximum residential customer charge as per Docket 17-01-12, which was consistent with PA 15-5, June Special Session (§ 105). The decision established that the Company's residential fixed charge should only recover the fixed costs and operation and maintenance expenses directly related to metering, billing, service connections, and providing Cover Agreement – CL&P ACOS and MCS CRA International Inc. Page 19 Eversource ConfidentialPage 20 of 238
The Connecticut Light and Power Company d/b/a Eversource Energy REDACTED Docket No. 26-05-10 Date Issued September 2, 2026 ALLCO-027 Attachment 5 REDACTED Page 20 of 238 customer service. It also prohibited PURA, when determining new residential fixed charges, from causing a cost-shift to other rate classes. The MCS results will be evaluated along with ACOS results for rate design. Ideally, for efficiency goals, every customer should face a price for marginal consumption that is closer to the marginal unit cost. To keep prices closer to marginal costs, higher recovery of local distribution costs through a subscription based on customer size or potentially a demand charge may be warranted, particularly given the restrictions on the customer charge level. When taking this approach, customer affordability tends to improve because it is less likely that customers’ bills are unnecessarily high (above cost) during the coldest winter months or the summer months when overall energy usage is higher. In addition to the traditional two-part rates with one fixed monthly customer charge and volumetric, perkWh charges, there is merit in exploring the feasibility of offering multi-part rates to residential customers, which can include monthly or daily demand charges and/or monthly subscription fees to ensure more equitable intra-class allocation. We will explore the potential cost basis of such charges and lessons to date designing these rates for residential customers. Finally, energy efficiency and affordability goals can also be met with rates that change as system conditions change. Examples include critical peak pricing (CPP) and real-time pricing (RTP). They result in more efficient consumption decisions compared to traditional non-dynamic rate structures with low fixed charges, and no time-differentiation. 8.3. Time of Use Rate Design for Further Flexibility Many utilities are embarking in a modernization of their retail rates, to maximize the benefits of time-of-use (TOU) rates upon AMI deployment. The team lead, Amparo Nieto, has been a key advisor to utilities across the country in these initiatives. For price signals to be efficient, TOU charges should aim to reflect how the cost impact of incremental customer electricity usage on the grid varies across hours. It is critical that the TOU periods be reflective of the hourly marginal cost profiles that can be expected during the timeframe the new TOU rates will be in effect. The hours most likely to experience peak load are most likely to drive decisions to expand the substation transformer or feeder. CRA will produce relative hourly probabilities of peak (POP) for 864 hours using typical Weekday, Saturday and Sunday by each month of the year, using hourly distribution substation load data. A PoP analysis provides estimates of each hour’s probability of being the annual distribution system peak load, relative to other hours and can be allocated to annual cost for the purpose of establishing efficient TOU periods. Marginal costs are useful for determining optimal seasons and periods when designing TOU rates. A probability of peak analysis will provide specific information on Eversource’s distribution grid and the specific set of hours. We expect it will reveal the need to use a shorter evening peak period relative to the current larger peak period in current Rate 7, to better reflect the hours of the day most likely to trigger investment to accommodate new load on the grid. Ultimately, the TOD period should rebalance the goal of reflecting the variation in marginal costs during the day with minimizing complexity for customers. We will provide optional TOU rates for the Company to consider and help decide on the choice of periods and seasons balancing goals of efficiency and customer understanding. Cover Agreement – CL&P ACOS and MCS CRA International Inc. Page 20 Eversource Confidential
Text of ALLCO-027 Attachment 7 REDACTED (1).pdf
Extracted from the file · 41 pages, 19 without text · 46,195 characters
As listed on the current system
Question(s) Answered 27 (CL&P dba Eversource Energy) Date Filed: 09/24/2026