Interrogatory responses
Answers to questions 1, 2, 3, 4, 5, 6, 7, 8, 9
Files14
CT PURA 26-05-10 CLF Response CIEC-2-001.pdf
PDF · 207 KB · 6 pagesText searchable
Download CT PURA 26-05-10 CLF Response CIEC-2-001.pdfRead the text of CT PURA 26-05-10 CLF Response CIEC-2-001.pdf
CIEC-1a_rate_hp_revenue_reduction.xlsx
Excel · 16 KBText searchable
Download CIEC-1a_rate_hp_revenue_reduction.xlsxRead the text of CIEC-1a_rate_hp_revenue_reduction.xlsx
CT PURA 26-05-10 CLF Response CIEC-2-002.pdf
PDF · 192 KB · 5 pagesText searchable
Download CT PURA 26-05-10 CLF Response CIEC-2-002.pdfRead the text of CT PURA 26-05-10 CLF Response CIEC-2-002.pdf
CIEC-2d_rdm_tac_nonres_impact.xlsx
Excel · 12 KBText searchable
Download CIEC-2d_rdm_tac_nonres_impact.xlsxRead the text of CIEC-2d_rdm_tac_nonres_impact.xlsx
CT PURA 26-05-10 CLF Response CIEC-2-003.pdf
PDF · 159 KB · 2 pagesText searchable
Download CT PURA 26-05-10 CLF Response CIEC-2-003.pdfRead the text of CT PURA 26-05-10 CLF Response CIEC-2-003.pdf
CIEC-3c_rate1_charge_increase.xlsx
Excel · 197 KBText searchable
Download CIEC-3c_rate1_charge_increase.xlsxRead the text of CIEC-3c_rate1_charge_increase.xlsx
CT PURA 26-05-10 CLF Response CIEC-2-004.pdf
PDF · 247 KB · 2 pagesText searchable
Download CT PURA 26-05-10 CLF Response CIEC-2-004.pdfRead the text of CT PURA 26-05-10 CLF Response CIEC-2-004.pdf
CT PURA 26-05-10 CLF Response CIEC-2-005.pdf
PDF · 114 KB · 1 pageText searchable
Download CT PURA 26-05-10 CLF Response CIEC-2-005.pdfRead the text of CT PURA 26-05-10 CLF Response CIEC-2-005.pdf
CT PURA 26-05-10 CLF Response CIEC-2-006.pdf
PDF · 146 KB · 2 pagesText searchable
Download CT PURA 26-05-10 CLF Response CIEC-2-006.pdfRead the text of CT PURA 26-05-10 CLF Response CIEC-2-006.pdf
CIEC-6c_nonhp_bill_increase.xlsx
Excel · 11 KBText searchable
Download CIEC-6c_nonhp_bill_increase.xlsxRead the text of CIEC-6c_nonhp_bill_increase.xlsx
CT PURA 26-05-10 CLF Response CIEC-2-007.pdf
PDF · 177 KB · 4 pagesText searchable
Download CT PURA 26-05-10 CLF Response CIEC-2-007.pdfRead the text of CT PURA 26-05-10 CLF Response CIEC-2-007.pdf
CT PURA 26-05-10 CLF Response CIEC-2-008.pdf
PDF · 206 KB · 6 pagesText searchable
Download CT PURA 26-05-10 CLF Response CIEC-2-008.pdfRead the text of CT PURA 26-05-10 CLF Response CIEC-2-008.pdf
CT PURA 26-05-10 CLF Response CIEC-2-009.pdf
PDF · 149 KB · 3 pagesText searchable
Download CT PURA 26-05-10 CLF Response CIEC-2-009.pdfRead the text of CT PURA 26-05-10 CLF Response CIEC-2-009.pdf
CIEC-9c_winter_peak_marginal_cost.xlsx
Excel · 978 KBText searchable
Download CIEC-9c_winter_peak_marginal_cost.xlsxRead the text of CIEC-9c_winter_peak_marginal_cost.xlsx
Text of CIEC-2d_rdm_tac_nonres_impact.xlsx
Sheet names, column headings and text cells; numbers left out
Text of CT PURA 26-05-10 CLF Response CIEC-2-003.pdf
Extracted from the file · 2 pages · 7,236 characters
The searchable text of a spreadsheet keeps the sheet names, column headings and text cells. Download the file for the figures.
Part 1
[Sheet: README] CIEC-3(c) workpaper Docket No. 26-05-10. Witness: Juan-Pablo Velez. Request from Connecticut Industrial Energy Consumers. Increase in the Rate 1 distribution and transmission charges if the net revenue reduction from Rate HP were recovered solely from residential customers who are not on Rate HP. The reduction comes from existing heat pump customers who are auto-enrolled in Rate HP. New heat pump customers who enroll at installation pay slightly more than they did before installing a heat pump, so they do not add to the reduction. The response to CIEC-3(c) cites 2031 under the high estimate of new heat pump customers (increase sheet, last row). Yellow cells are inputs. Every other number is a formula. revenue Net revenue reduction in each rate year, from CIEC-1(a), Tables 1 and 2: revenue lost from existing heat pump customers auto-enrolled in Rate HP, minus revenue gained from new heat pump customers enrolled at installation. Customers are everyone on Rate HP that year, existing and new. The low and high estimates are the low and high estimates of new heat pump customers in CIEC-1(c). Distribution and transmission are the values calculated there, rounded to the dollar. This sheet does not recompute them. T&D adds the two components. nonhp_kwh One row per home without a heat pump in the ResStock 2024.2 sample of Eversource's territory used in Mr. Velez's direct testimony (Exhibit JPV-2, Section 2). Annual kWh is the electricity the home draws from the grid in a year. Weight is the number of customers the home represents. Homes on Rates 5 and 7 are included with Rate 1. The payers sheet scales the total to the Rate Year. payers Heat pump customers on Rate HP, and the residential customers who remain and pay the increase. The Rate Year count is an input, the average bills rendered for Rates 1, 5, and 7. Customers who remain are that count minus the customers on Rate HP. The scale is the customers who remain divided by the ResStock weight sum. Weighted kWh is the ResStock weighted kWh times that scale. Each year and estimate has its own scale, because a different number of customers are on Rate HP. rates The Company's proposed Rate 1 charges for the Rate Year (Exhibit CLP-RATES-3), the denominator of the percent change. Distribution includes riders and is flat across months. Transmission is flat across months. T&D is distribution plus transmission. The customer charge is unchanged and is not part of the percent. increase Each row divides that year's net revenue reduction by that year's weighted kWh on payers, under each estimate. Distribution and transmission are separate. T&D adds them. % of T&D divides the combined increase by the T&D rate. [Sheet: revenue] Net revenue reduction Net revenue reduction from CIEC-1(a): revenue lost from existing heat pump customers who move to Rate HP, minus revenue gained from new heat pump customers who enroll at installation. Customers are everyone on Rate HP that year. Low and high are the estimates of new heat pump customers in CIEC-1(c). Distribution and transmission are inputs, already rounded to the dollar. T&D adds them. Rate year | Low: customers on Rate HP | Low: distribution | Low: transmission | Low: T&D | High: customers on Rate HP | High: distribution | High: transmission | High: T&D [Sheet: nonhp_kwh] Non-heat-pump electricity use Homes without a heat pump in the ResStock 2024.2 sample of Eversource's territory (Exhibit JPV-2, Section 2). Annual kWh is the electricity the home draws from the grid in a year, the same basis as the bills in CIEC-1(a). Weight is the number of customers the home represents. Weighted kWh is annual kWh times that weight. Homes on Rates 5 and 7 are included with Rate 1. Total weighted kWh Buildings ResStock customers bldg_id | weight | annual kWh | weighted kWh [Sheet: payers] Customers who move and customers who payPart 2
Heat pump customers on Rate HP, and the residential customers who remain. The Rate Year count is the average bills rendered for Rates 1, 5, and 7. Customers who remain are that count minus the customers on Rate HP. The scale divides the customers who remain by the ResStock weight sum on nonhp_kwh. Weighted kWh multiplies the ResStock weighted kWh by that scale. The increase sheet divides each year's net revenue reduction by that year's weighted kWh. Rate Year residential customers ResStock non-HP customers ResStock non-HP kWh Rate year | Low: customers on Rate HP | Low: customers who remain | Low: scale | Low: weighted kWh | High: customers on Rate HP | High: customers who remain | High: scale | High: weighted kWh [Sheet: rates] Rate 1 charges The Company's proposed Rate 1 charges for the Rate Year (Exhibit CLP-RATES-3), used as the denominator of the percent change. Distribution includes riders. Transmission is separate. Both are flat across months. The customer charge is unchanged and is not part of the percent. Component | Unit | $/kWh | ¢/kWh | Note Distribution | $/kWh | Includes riders. Flat across months. Transmission | $/kWh | Flat across months. T&D | $/kWh | Denominator of % of T&D. [Sheet: increase] Rate 1 charge increase Each increase is that year's net revenue reduction divided by that year's weighted kWh on payers. Distribution and transmission are separate, and T&D adds them. % of T&D divides the combined increase by the T&D rate. The response to CIEC-3(c) cites 2031 under the high estimate. Rate year | Low: distribution ($/kWh) | Low: transmission ($/kWh) | Low: T&D ($/kWh) | Low: % of T&D | High: distribution ($/kWh) | High: transmission ($/kWh) | High: T&D ($/kWh) | High: % of T&D
Text of CT PURA 26-05-10 CLF Response CIEC-2-004.pdf
Extracted from the file · 2 pages · 5,169 characters
Text of CT PURA 26-05-10 CLF Response CIEC-2-005.pdf
Extracted from the file · 1 page · 3,089 characters
Text of CT PURA 26-05-10 CLF Response CIEC-2-006.pdf
Extracted from the file · 2 pages · 5,277 characters
Text of CIEC-6c_nonhp_bill_increase.xlsx
Sheet names, column headings and text cells; numbers left out
Text of CT PURA 26-05-10 CLF Response CIEC-2-007.pdf
Extracted from the file · 4 pages · 12,255 characters
Text of CT PURA 26-05-10 CLF Response CIEC-2-008.pdf
Extracted from the file · 6 pages · 22,930 characters
Text of CT PURA 26-05-10 CLF Response CIEC-2-009.pdf
Extracted from the file · 3 pages · 7,227 characters
Text of CIEC-9c_winter_peak_marginal_cost.xlsx
Sheet names, column headings and text cells; numbers left out
As listed on the current system
Question(s) Answered 1, 2, 3, 4, 5, 6, 7, 8, 9 (Conservation Law Foundation) Date Filed: 11/16/2026