Interrogatory responses
Answers to questions 2 thru 20
Files10
OCC Response to CIEC Second Set of Requests.pdf
PDF · 571 KB · 25 pagesText searchable
Download OCC Response to CIEC Second Set of Requests.pdfRead the text of OCC Response to CIEC Second Set of Requests.pdf
Response to CIEC-2 (a) Classification of AMI-related costs.xlsx
Excel · 16 KBText searchable
Download Response to CIEC-2 (a) Classification of AMI-related costs.xlsxRead the text of Response to CIEC-2 (a) Classification of AMI-related costs.xlsx
Response to CIEC-8 (b) Allocation of AMI meter costs.xlsx
Excel · 16 KBText searchable
Download Response to CIEC-8 (b) Allocation of AMI meter costs.xlsxRead the text of Response to CIEC-8 (b) Allocation of AMI meter costs.xlsx
CIEC-9 (d) Attachment A C17-0556_16A-0588E.pdf
PDF · 177 KB · 16 pagesText searchable
Download CIEC-9 (d) Attachment A C17-0556_16A-0588E.pdfRead the text of CIEC-9 (d) Attachment A C17-0556_16A-0588E.pdf
CIEC-9 (d) Attachment B 2023-CO-Phase-II-Electric-Rate-Review-Decision.pdf
PDF · 476 KB · 45 pagesText searchable
Download CIEC-9 (d) Attachment B 2023-CO-Phase-II-Electric-Rate-Review-Decision.pdfRead the text of CIEC-9 (d) Attachment B 2023-CO-Phase-II-Electric-Rate-Review-Decision.pdf
CIEC-12 Attachment - Bonbright Excerpt.pdf
PDF · 136 KB · 4 pagesText read by machine from a scan; may contain errors, especially in numbers
Download CIEC-12 Attachment - Bonbright Excerpt.pdfScanned pages and text of CIEC-12 Attachment - Bonbright Excerpt.pdf
CIEC-13 (a) Attachment - rate_order_Hydro One DX 2013_20121220.pdf
PDF · 245 KB · 31 pagesText searchable
Download CIEC-13 (a) Attachment - rate_order_Hydro One DX 2013_20121220.pdfRead the text of CIEC-13 (a) Attachment - rate_order_Hydro One DX 2013_20121220.pdf
CIEC-13 (d) - Hydro One Density Study HONI_APPL_Exhibit D_20120615.pdf
PDF · 3.3 MB · 99 pagesText searchable
Download CIEC-13 (d) - Hydro One Density Study HONI_APPL_Exhibit D_20120615.pdfRead the text of CIEC-13 (d) - Hydro One Density Study HONI_APPL_Exhibit D_20120615.pdf
CIEC-20 (d) Attachment 1 - PG&E Rate B-20.pdf
PDF · 1.9 MB · 24 pagesText searchable
Download CIEC-20 (d) Attachment 1 - PG&E Rate B-20.pdfRead the text of CIEC-20 (d) Attachment 1 - PG&E Rate B-20.pdf
CIEC-20 (d) Attachment 2 - PSCo Schedule PG.pdf
PDF · 198 KB · 3 pagesText searchable
Download CIEC-20 (d) Attachment 2 - PSCo Schedule PG.pdfRead the text of CIEC-20 (d) Attachment 2 - PSCo Schedule PG.pdf
Text of CIEC-9 (d) Attachment A C17-0556_16A-0588E.pdf
Extracted from the file · 16 pages · 28,745 characters
Text of CIEC-9 (d) Attachment B 2023-CO-Phase-II-Electric-Rate-Review-Decision.pdf
Extracted from the file · 45 pages · 89,290 characters
Scanned pages of CIEC-12 Attachment - Bonbright Excerpt.pdf
Read by machine from a scan · 4 pages · may contain errors, especially in numbers
Text of CIEC-13 (a) Attachment - rate_order_Hydro One DX 2013_20121220.pdf
Extracted from the file · 31 pages · 41,898 characters
Page 1 of 99
Filed: June 15, 2012 EB-2012-0136 Exhibit D Tab 1 Schedule 1 Page 1 of 10 DENSITY STUDY 1 2 3 Hydro One has completed a study of the relationship between customer density and cost 4 allocation to satisfy the direction from the Board in their Decision on the 2010/11 rate 5 application EB-2009-0096. 6 relationship between customer density and distribution service costs; ii) assess whether 7 the existing density based rate classes and density weighting factors appropriately reflect 8 this relationship; and, iii) consider the possibility of establishing alternate customer class 9 definitions. The objectives of the study were to: i) evaluate the 10 11 Hydro One met with stakeholders on September 8, 2010 to get their input on how to 12 proceed in responding to the Board’s direction on this issue. The notes of meeting from 13 that stakeholder session are provided as Appendix A to Exhibit A, Tab 4, Schedule 1. 14 Among the feedback received from stakeholders was that it would be desirable to apply 15 more than one method or model to complete the study in order to increase the accuracy 16 and confidence in the results. A number of stakeholders also suggested the importance of 17 first establishing the relationship between density and cost before proceeding to establish 18 what that might mean for existing density-based customer classes. 19 20 In response to the feedback received at the first stakeholder session, Hydro One engaged 21 London Economics International (LEI) and PowerNex Associates (PNXA) to develop a 22 methodology for completing a study that satisfied the Board’s direction, while being 23 mindful of the need to take into consideration timing, feasibility and cost in completing 24 the study. LEI/PNXA developed and tested a proposed methodology for completing the 25 study as part of a staged approach to engaging their services. The proposed methodology 26 consisted of using two approaches to explore the relationship between density and cost- 27 to-serve: an econometric analysis and a direct-cost assignment analysis. A second 28 stakeholder session was held on March 22, 2011 to solicit stakeholder input on thePage 2 of 99
Filed: June 15, 2012 EB-2012-0136 Exhibit D Tab 1 Schedule 1 Page 2 of 10 1 proposed study methodology. The notes of meeting from this second stakeholder session 2 are provided as Appendix B to Exhibit A, Tab 4, Schedule 1. Stakeholders were 3 supportive of the proposed methodology. 4 5 On October 19, 2011, Hydro One held a stakeholder session which provided a summary 6 of the implementation of the study methodology and reviewed the results and findings of 7 the Density Study. The notes of meeting from this third stakeholder session are provided 8 as Appendix D to Exhibit A, Tab 4, Schedule 1. 9 10 A final stakeholder session was held on June 5, 2012 to review options for implementing 11 the findings of the Density Study as part of the current 2013 IRM application. The notes 12 of meeting from this fourth stakeholder session are provided as Appendix E to Exhibit A, 13 Tab 4, Schedule 1. 14 15 The Density Study report prepared by LEI/PNXA that Hydro One believes satisfies the 16 Direction from the Board in their Decision under proceeding EB-2009-0096 is provided 17 as Attachment 1 to this Exhibit. 18 19 The Density Study concludes that the results of both the econometric and direct cost 20 assignment approaches used in the study demonstrate there is a statistically significant 21 relationship between customer density and distribution service costs. Both analyses 22 clearly show that Hydro One’s distribution service costs decrease as customer density 23 increases. The ratio between the cost per customer of serving high density (HD), medium 24 density (MD) and low density (LD) areas are shown in Figures 27 and 28 of the Density 25 Study and summarized in Table 1. 26Page 3 of 99
Filed: June 15, 2012 EB-2012-0136 Exhibit D Tab 1 Schedule 1 Page 3 of 10 1 Table 1 2 Density Study Findings on Relative Costs of Serving Different Density Areas 3 4 1 HD MD LD Ratio of OM&A1 and Fixed Asset Costs 1.0 1.9 4.8 Ratio of Total Costs 1.0 1.7 3.9 Excludes customer-related costs (except meter reading and customer premises work) and Administrative and General costs. 5 6 The Density Study results confirm the appropriateness of having density-based rate 7 classes. Hydro One currently uses density weighting factors within the Board’s cost 8 allocation model (CA Model) to allocate overhead line and transformer costs between its 9 density-based rate classes. The density weighting factors currently approved by the Board 10 allocate costs among the Residential, General Service Energy and General Service 11 Demand classes separately. The cost per customer account as determined from the 12 results of the 2010 CA Model submitted in Hydro One Distribution’s last Cost of Service 13 (“COS”) application EB-2009-0096 are calculated in Table 2. 14 15 Table 2. 16 Cost Per Customer from the 2010 CA Model UR R1 R2 Seasonal UGe GSe UGd GSd # of Customer Accounts 140,540 412,455 367,107 156,901 10,577 98,776 1,130 7,361 Total Cost ($M) $59.0 $273.4 $431.7 $96.0 $8.7 $121.5 $12.6 $128.8 Total Cost per Customer $420 $663 $1,176 $612 $818 $1,230 $11,128 $17,491 1.0 1.6 2.8 1.5 1.0 1.5 1.0 1.6 $44.7 $223.0 $367.4 $84.0 $6.7 $99.9 $11.1 $115.4 $318 $541 $1,001 $535 $633 $$1,011 $9,826 $15,679 1.0 1.7 3.1 1.7 1.0 1.6 1.0 1.6 Ratio of Total Cost per Cust relative to Urban OM&A1 and Fixed Asset (FA) Cost ($M) OM&A and FA Cost per Customer Ratio of OM&A and FA Cost per Cust relative to Urban 17 18 1 Total costs excluding customer related costs (except meter reading and customer premises work) and Administrative & General costsPage 4 of 99
Filed: June 15, 2012 EB-2012-0136 Exhibit D Tab 1 Schedule 1 Page 4 of 10 1 A comparison of the relative cost ratios from Tables 1 and 2 clearly shows that the costs 2 allocated by the 2010 CA Model understate the relative cost of serving density-based rate 3 classes as determined by the Density Study. 4 5 Hydro One proposes to revise the allocation of costs to its density-based rate classes by 6 adjusting the ratio between the cost per customer allocated by the 2010 CA Model to 7 more closely align with the Density Study results. 8 9 The target cost ratio for the General Service Energy (GSe) rate class relative to the Urban 10 General Service Energy (UGe) rate class has been set to a value between that of the 11 medium and low density areas as determined by the Density Study. The proposed target 12 cost ratio for the GSe class is based on consideration of the actual relative density of 13 Hydro One’s GSe customers as compared to UGe customers.1 The target cost ratio for 14 the General Service Demand (GSd) rate class relative to the Urban General Service 15 Demand (UGd) rate class has been set at the value for the medium density area as 16 determined by the Density Study.2 17 18 The target ratio for the Seasonal class has been set equal to that of the R1 class, consistent 19 with the CA Model output which shows the total cost per customer for these two rate 20 classes is about the same despite the existing weighting factors for the Seasonal classes 21 being between that of the medium and low rate classes, as suggested by the findings of 22 the Density Study. 23 1 Based on an assessment of the # of customers per km of line for all Hydro One rate classes, the density of the GSe rate class is 5.4 times that of UGe rate class, which compares to a relative density of 3.9 times for the R1 residential rate class and 10.0 times for the R2 residential rate class, as compared to the urban (UR) residential rate class. 2 Based on an assessment of the # of customers per km of line for all Hydro One rate classes, Hydro One’s GSd customers have about the same relative density when compared to UGd customers as the medium residential (R1) rate class has relative to the urban residential (UR) rate class.Page 5 of 99
Filed: June 15, 2012 EB-2012-0136 Exhibit D Tab 1 Schedule 1 Page 5 of 10 1 Two options were considered for adjusting the costs per customer determined by the 2 2010 CA Model to match the cost ratios specified by the Density Study. Table 3 shows 3 the impacts of making the Density Study adjustment (DSA) based on the total costs 4 allocated by the CA Model, while Table 4 shows the impacts of adjusting only the 5 OM&A (excluding customer related and Administrative & General cost) and Fixed Asset 6 costs. 7 8 Table 3. 9 Density Study-Adjusted (DSA) CA Model Results Based on Total Costs UR R1 R2 Seasonal UGe GSe UGd GSd 1.0 1.7 3.9 1.7 1.0 2.2 1.0 1.7 $339 $576 $1,320 $576 $571 $1,257 $10,359 $17,609 DSA Total Cost ($M) $47.6 $237.4 $484.7 $90.3 $6.0 $124.1 $11.7 $129.6 Revenue Collected ($M) $64.5 $253.8 $450.0 $98.6 $10.4 $130.1 $15.7 $113.4 1.36 1.07 0.93 1.09 1.73 1.06 1.34 0.87 1.09 0.93 1.04 1.03 1.21 1.07 1.25 0.88 Target Cost per Customer Ratio DSA Total Cost per Customer DSA Revenue to Cost (R/C) Ratio 2010 R/C Ratio per CA Model 10 11 Table 4 12 Density Study-Adjusted (DSA) CA Model results based on OM&A and Fixed Asset (FA) Costs 13 UR R1 R2 Seasonal UGe GSe UGd GSd 1.0 1.9 4.8 1.9 1.0 2.6 1.0 1.9 $241 $458 $1,157 $458 $399 $1,037 $8,370 $15,903 $33.9 $188.8 $424.6 $71.8 $4.2 $102.4 $9.5 $117.1 DSA Total Cost ($M) $48.1 $239.2 $488.8 $83.9 $6.2 $124.0 $10.9 $130.4 Revenue Collected ($M) $64.5 $253.8 $450.0 $98.6 $10.4 $130.1 $15.7 $113.4 1.34 1.06 0.92 1.17 1.69 1.05 1.44 0.87 1.09 0.93 1.04 1.03 1.21 1.07 1.25 0.88 Target Cost per Customer Ratio DSA OM&A and FA Cost per Customer DSA OM&A and FA Costs ($M) DSA Revenue to Cost (R/C) Ratio 2010 R/C Ratio per CA ModelPage 6 of 99
Filed: June 15, 2012 EB-2012-0136 Exhibit D Tab 1 Schedule 1 Page 6 of 10 1 Hydro One proposes to adopt the second approach shown in Table 4. This approach was 2 supported by stakeholders and provides better alignment between the costs specifically 3 addressed by the Density Study and the CA Model costs. This approach also ensures that 4 the allocation of the customer related OM&A and A&G costs, which are largely 5 independent of density, will remain as allocated by the CA Model. 6 7 As shown in Table 4, the density study-adjusted revenue-to-cost (R/C) ratio for the urban 8 density rate classes and Seasonal rate class are well above the R/C ratios that were 9 approved by the Board in the last COS application and are outside the Board approved 10 R/C ratio ranges for these rate classes. This indicates that under current rates, the amount 11 of revenue collected from the urban Residential and General Service rate classes, as well 12 as the Seasonal rate class, is in excess of what the Density Study results demonstrate to 13 be appropriate. Hydro One believes this disparity needs to be addressed as part of its 14 2013 IRM application. 15 16 Hydro One considered two options for addressing this disparity. Option 1 is to lower the 17 revenues to be collected from those rate classes that are outside the Board approved R/C 18 ratio range to the Board-approved R/C ratio limit for those rate classes. Option 2 would 19 be to lower the R/C ratios for those rate classes to the R/C ratios previously approved by 20 the Board as part of Hydro One’s last COS application, EB-2009-0096. 21Page 7 of 99
Filed: June 15, 2012 EB-2012-0136 Exhibit D Tab 1 Schedule 1 Page 7 of 10 1 Table 5 2 Revenue Adjustments Required to Bring R/C Ratios to Limits of Board Approved Ranges (All $ in millions) UR R1 R2 Seasonal UGe GSe UGd GSd $113.4 $130.4 0.91 $118.5 $5.1 Street Lights $6.5 $9.5 0.71 $6.7 $0.3 Sentinel Lights $5.1 $7.6 0.7 $5.3 $0.2 2010 CA Model Revenues DSA Total Cost Target R/C Ratio Target Revenue to be recovered Revenue Adjustment Required to achieve Target R/C Average Rate Impacts $64.5 $48.1 1.15 $55.3 - $9.2 $253.8 $239.2 1.06 $253.8 None $450.0 $488.8 0.94 $461.3 + $11.3 $98.6 $83.9 1.15 $96.5 - $2.1 $10.4 $6.2 1.20 $7.4 - $3.0 $130.1 $124.0 1.05 $130.1 None $15.7 $10.9 1.20 $13.1 -$2.6 -14.3% None +2.5% -2.1% -29.1% None -16.4% +4.5% +4.5% +4.5% Street Lights $5.1 $7.6 0.70 $5.3 $0.3 +5.1% 3 4 5 Table 6 6 Revenue Adjustments Required to Bring R/C Ratios to Previously Approved R/C Levels 7 8 (All $ in millions) UR R1 R2 Seasonal $98.6 $83.9 1.03 $86.1 - $12.5 Urban GSe $10.4 $6.2 1.21 $7.4 - $3.0 2010 CA Model Revenues DSA Total Cost Target R/C Ratio Target Revenue to be recovered Revenue Adjustment Required to achieve Target R/C Average Rate Impacts $64.5 $48.1 1.09 $52.6 - $11.9 $253.8 $239.2 1.06 $253.8 None $450.0 $488.8 0.97 $473.0 + $23.0 -18.4% None +5.1% -12.6% -28.7% GSe $130.1 $124.0 1.05 $130.1 None Urban GSd $15.7 $10.9 1.25 $13.6 -$2.1 GSd $113.4 $130.4 0.91 $119.2 $5.8 Sentinel Lights $6.5 $9.5 0.72 $6.8 $0.3 None -13.1% +5.1% +5.1%Page 8 of 99
Filed: June 15, 2012 EB-2012-0136 Exhibit D Tab 1 Schedule 1 Page 8 of 10 1 The detailed calculations associated with both options for adjusting the 2010 CA Model results 2 in response to the Density Study findings are provided in Attachment 2 to this Exhibit, and 3 summarized in Tables 5 and 6. Table 5 shows the impacts of implementing Option 1 and Table 6 4 shows the impact of implementing Option 2. For both options, the revenue to be shifted from the 5 affected rate classes in order to bring the R/C ratios for those rate classes to the target values will 6 be allocated to those rate classes whose R/C ratio is below 1 (i.e. the Low Density (R2) 7 residential rate class, the GSd rate class, and the Sentinel and Street Lighting rate classes). 8 9 Option 2 results in rates for the residential rate classes that more closely reflect the cost of 10 serving those classes, since the R/C ratios are closer to 1, and it would address the existing rate 11 disparity between the classes more quickly than Option 1. However, Option 2 also results in 12 more significant rate impacts to the affected rate classes. 13 14 Hydro One believes that implementation of the Density Study findings represents an 15 improvement to the allocation of costs to its customer classes. Such an improvement to the 16 allocation of costs would merit moving beyond the Board-approved limit for the R/C ratio of its 17 density based classes to get closer to a R/C value of 1.0. However, as noted by a number of 18 participants at the June 5 stakeholder session, adopting a staged approach to the implementation 19 of the Density Study findings will help mitigate the rate impact on customers. As such, Hydro 20 One proposes moving to the Board-approved limits for the R/C ratios (Option 1) as part of its 21 2013 IRM application. 22 23 In adopting Option 1, Hydro One proposes to re-allocate the revenue to be shifted from the urban 24 General Service classes to both the General Service Demand and Lighting classes in a manner 25 that results in equivalent rate impacts to those classes. Hydro One further proposes that the 26 revenue to be shifted from the Urban and Seasonal residential rate classes be allocated to the 27 Low Density (R2) rate class. Hydro One does not propose that any revenue from the Urban 28 Residential and Seasonal rate classes be shifted to the General Service Demand and LightingPage 9 of 99
Filed: June 15, 2012 EB-2012-0136 Exhibit D Tab 1 Schedule 1 Page 9 of 10 1 classes given that the rate impact of 4.5% experienced by those classes is already above the 2.5% 2 rate impact experienced by the R2 rate class. 3 4 As detailed in Attachment 3 to this Exhibit, and summarized in Table 7, Hydro One has 5 determined the impact on current rates for the affected rate classes of making the proposed 6 revenue adjustments described above, and subsequently updating the rates for the approved IRM 7 increase of 0.88%. 8 9 Table 7 10 Proposed 2013 Density Study Adjusted IRM Rates Rate Class Fixed Charge $/month UR R1 R2 Seasonal GSe GSd UGe UGd St Light Sen Light Current Rates Variable Charge Density Study Adjusted IRM Rates Fixed Variable Charge Charge $/month $/kWh $/kW $/kWh $/kW 14.52 0.02918 - 12.56 0.02524 - 19.72 0.03317 - 19.89 0.03346 - 55.69 0.03600 - 57.58 0.03723 - 19.71 0.08205 - 19.46 0.08101 - 35.49 0.03938 - 35.80 0.03973 - 47.72 - 10.499 50.37 - 11.079 14.08 0.02325 - 10.07 0.01663 - 33.62 - 8.173 28.35 - 6.900 1.05 0.05219 - 1.10 0.05502 - 1.05 0.06972 - 1.10 0.07355 - 11 12 Proposed Rate Schedules based on the Density Study adjusted IRM rates are provided in Exhibit 13 E2, Tab 2, Schedule 3. Updated total monthly bill impacts based on the Density Study adjusted 14 IRM rates and including all proposed rate riders and adders, are provided in Exhibit E2, Tab 3, 15 Schedule 2 for each rate affected rate class. A comparison of the IRM Total Bill impacts (as per 16 per Exhibit Exhibit E3, Tab 3, Schedule 1) versus Density Study Adjusted (DSA) IRM Total Bill 17 Impacts are summarized in Table 8.Page 10 of 99
Filed: June 15, 2012 EB-2012-0136 Exhibit D Tab 1 Schedule 1 Page 10 of 10 1 Table 8 2 Comparison of Proposed 2013 Density Study Adjusted IRM Total Bill Impacts Customer Type Residential – High Density (UR) Residential – Low Density (R2) Residential Seasonal Urban GSe GSe Urban GSd GSd Street Lights Sentinel Lights Monthly Consumption (kWh, kW) IRM DSA IRM IRM DSA IRM IRM DSA IRM IRM DSA IRM IRM DSA IRM IRM DSA IRM IRM DSA IRM IRM DSA IRM IRM DSA IRM 800 kWh 800 kWh 800 kWh 800 kWh 500 kWh 500 kWh 2,000 kWh 2,000 kWh 2,000 kWh 2,000 kWh 36,000 kWh, 117 kW 36,000 kWh, 117 kW 36,000 kWh, 117 kW 36,000 kWh, 117 kW 1,320 kWh 1,320 kWh 62 kWh 62 kWh Current Total Monthly Bill ($) 132.26 132.26 151.74 151.74 116.61 116.61 296.95 296.95 351.09 351.09 5,241.08 5,241.08 5,519.56 5,519.56 241.11 241.11 11.76 11.76 Proposed Total Monthly Bill ($) 134.75 129.22 155.79 157.96 120.24 118.92 300.27 282.18 357.28 357.28 5,296.43 5,130.74 5,592.20 5,652.48 244.79 248.30 12.04 12.29 Change ($) Change (%) 2.49 -3.05 4.05 6.22 3.63 2.30 3.32 -14.77 6.19 6.19 55.35 -110.34 72.63 132.92 3.68 7.19 0.28 0.52 1.88% -2.30% 2.67% 4.10% 3.11% 1.98% 1.12% -4.97% 1.76% 1.76% 1.06% -2.11% 1.32% 2.41% 1.53% 2.98% 2.37% 4.45% 3 4 At this time Hydro One is not proposing any changes to the number, or delineation, of its 5 existing rate classes in response to the Density Study findings. The Density Study indicates that 6 three density-based residential classes and two density-based general service classes appear 7 reasonable and based on the results of the study, there does not appear to be an immediate or 8 pressing need to change the number of existing density-based rate classes.
Text of CIEC-20 (d) Attachment 1 - PG&E Rate B-20.pdf
Extracted from the file · 24 pages · 63,774 characters
Text of CIEC-20 (d) Attachment 2 - PSCo Schedule PG.pdf
Extracted from the file · 3 pages · 7,608 characters
As listed on the current system
Question(s) Answered 2 thru 20 (OCC) Date Filed: 11/12/2026