Interrogatory responses
Answers to questions 2 thru 20
Files10
OCC Response to CIEC Second Set of Requests.pdf
PDF · 571 KB · 25 pagesText searchable
Download OCC Response to CIEC Second Set of Requests.pdfRead the text of OCC Response to CIEC Second Set of Requests.pdf
Response to CIEC-2 (a) Classification of AMI-related costs.xlsx
Excel · 16 KBText searchable
Download Response to CIEC-2 (a) Classification of AMI-related costs.xlsxRead the text of Response to CIEC-2 (a) Classification of AMI-related costs.xlsx
Response to CIEC-8 (b) Allocation of AMI meter costs.xlsx
Excel · 16 KBText searchable
Download Response to CIEC-8 (b) Allocation of AMI meter costs.xlsxRead the text of Response to CIEC-8 (b) Allocation of AMI meter costs.xlsx
CIEC-9 (d) Attachment A C17-0556_16A-0588E.pdf
PDF · 177 KB · 16 pagesText searchable
Download CIEC-9 (d) Attachment A C17-0556_16A-0588E.pdfRead the text of CIEC-9 (d) Attachment A C17-0556_16A-0588E.pdf
CIEC-9 (d) Attachment B 2023-CO-Phase-II-Electric-Rate-Review-Decision.pdf
PDF · 476 KB · 45 pagesText searchable
Download CIEC-9 (d) Attachment B 2023-CO-Phase-II-Electric-Rate-Review-Decision.pdfRead the text of CIEC-9 (d) Attachment B 2023-CO-Phase-II-Electric-Rate-Review-Decision.pdf
CIEC-12 Attachment - Bonbright Excerpt.pdf
PDF · 136 KB · 4 pagesText read by machine from a scan; may contain errors, especially in numbers
Download CIEC-12 Attachment - Bonbright Excerpt.pdfScanned pages and text of CIEC-12 Attachment - Bonbright Excerpt.pdf
CIEC-13 (a) Attachment - rate_order_Hydro One DX 2013_20121220.pdf
PDF · 245 KB · 31 pagesText searchable
Download CIEC-13 (a) Attachment - rate_order_Hydro One DX 2013_20121220.pdfRead the text of CIEC-13 (a) Attachment - rate_order_Hydro One DX 2013_20121220.pdf
CIEC-13 (d) - Hydro One Density Study HONI_APPL_Exhibit D_20120615.pdf
PDF · 3.3 MB · 99 pagesText searchable
Download CIEC-13 (d) - Hydro One Density Study HONI_APPL_Exhibit D_20120615.pdfRead the text of CIEC-13 (d) - Hydro One Density Study HONI_APPL_Exhibit D_20120615.pdf
CIEC-20 (d) Attachment 1 - PG&E Rate B-20.pdf
PDF · 1.9 MB · 24 pagesText searchable
Download CIEC-20 (d) Attachment 1 - PG&E Rate B-20.pdfRead the text of CIEC-20 (d) Attachment 1 - PG&E Rate B-20.pdf
CIEC-20 (d) Attachment 2 - PSCo Schedule PG.pdf
PDF · 198 KB · 3 pagesText searchable
Download CIEC-20 (d) Attachment 2 - PSCo Schedule PG.pdfRead the text of CIEC-20 (d) Attachment 2 - PSCo Schedule PG.pdf
Text of CIEC-9 (d) Attachment A C17-0556_16A-0588E.pdf
Extracted from the file · 16 pages · 28,745 characters
Text of CIEC-9 (d) Attachment B 2023-CO-Phase-II-Electric-Rate-Review-Decision.pdf
Extracted from the file · 45 pages · 89,290 characters
Scanned pages of CIEC-12 Attachment - Bonbright Excerpt.pdf
Read by machine from a scan · 4 pages · may contain errors, especially in numbers
Text of CIEC-13 (a) Attachment - rate_order_Hydro One DX 2013_20121220.pdf
Extracted from the file · 31 pages · 41,898 characters
Page 35 of 99
Customer Density and Distribution Service Costs To put the magnitude of the increase in density into perspective, in the direct cost assignment analysis the high-density sample areas were 6.8 times denser on average than the mediumdensity sample areas. The medium-density sample areas were 7.2 times denser on average than the low-density sample areas. The 95 percent confidence interval of the density coefficient in all four models exclude zero. Thus the model demonstrates that customer density, regardless of how it is measured, is inversely related to distribution service costs. As customer density decreases, the cost to serve the same number of customers, all other factors being equal, would be expected to increase. The opposite also holds true where customer density increases, the cost to serve the same number of customers, holding all other variables constant, would be expected to decrease. The first objective of this study was to analyze the relationship between customer density and distribution service costs. The econometric analysis confirms that there is a statistically significant relationship, and that as customer density increases cost generally decrease, all else held equal. With this understanding, the direct cost assignment analysis described in the next chapter of this report attempts to confirm or refute this relationship at a more granular sample area level within selected operating areas. The direct cost assignment analysis also aims to explore the magnitude of the density-cost relationship. London Economics International LLC Benjamin Grunfeld/Steven Kim [phone removed] [email removed] 14 PowerNex Associates Inc. Mark Vainberg/Gary Ford/Andrew Poray [phone removed] [email removed]Page 36 of 99
Customer Density and Distribution Service Costs 4 Summary of Direct Cost Assignment Analysis 4.1 Introduction In the first phase of this engagement, the feasibility of a direct cost assignment analysis was investigated. The conclusion of that work established that such an analysis was feasible, and, when tested in one operating area, provided results which were considered by LEI and PNXA to be credible. In the second phase of this engagement, the direct cost assignment analysis was extended to 62 sample areas selected from 11 operating areas across HONI’s distribution service territory. The purpose of the direct cost assignment analysis was to investigate how the cost to serve customers over a broad range of customer densities varies. Sample areas were selected to represent three levels of density high, medium, and low (referred to as “HD”, “MD”, and “LD” respectively in the figures in this report), as well as to capture a representative range of the normal operating conditions that exist across HONI’s service territory. OM&A costs were directly assigned to the sample areas using a number of “assignment factors” that reflect engineering practices and utility operations. The assignment factors were selected based on an understanding of distribution system operations, types of assets, topology, and hence the principal drivers of cost.21 This assignment of OM&A costs allowed for the calculation of a per-customer OM&A cost for each sample area. The “asset intensity” was also calculated for each sample area, as a proxy for capital (nonoperating) costs. Asset intensity was defined as the replacement cost of the assets serving a sample area divided by the total number of customers contained within that sample area. 4.2 Data for Direct Cost Assignment Analysis The direct cost assignment analysis utilized a number of datasets from within HONI. A brief description of the major datasets collected is provided below. The number and length of distribution feeders, whether they pass through a sample area, and the length inside and outside each operating area and sample area. The number of customers in each sample area and operating area. The number of poles in each sample area and each operating area, including pole ownership (e.g., HONI-owned, Bell Canada owned, customer-owned, etc.) and type of pole mount (i.e., rock, earth, other).22 The total number and type of assets (e.g., transformers, switches, regulators, capacitors, re-closers, meters, etc.) in each sample area and operating area. 21 Background information on distribution systems and common terminology can be found in Appendix B. 22 It is quite common for utilities to share poles. HONI and Bell Canada have a pole sharing agreement in a number of locations across the province. Typically the owner of the pole is responsible for ongoing maintenance. London Economics International LLC Benjamin Grunfeld/Steven Kim [phone removed] [email removed] 15 PowerNex Associates Inc. Mark Vainberg/Gary Ford/Andrew Poray [phone removed] [email removed]Page 37 of 99
Customer Density and Distribution Service Costs The geographic coordinates of customers, poles, and service centers in each sample area and operating area. The number of interruptions and non-interruptions resulting from both storm and nonstorm related events for each operating area and each feeder.23 OM&A costs for each operating area and provincial-level programs. The typical replacement cost of assets currently used across HONI’s network. 4.3 Selection of Operating and Sample Areas Operating areas were selected to be representative of the range of conditions across HONI’s distribution service territory. The number of sample areas is important to assure the statistical significance of the results. Based on the preliminary results from the initial phase of the engagement, LEI and PNXA estimated that, at a minimum, 45 sample areas would likely be required to achieve a reasonable degree of confidence in the results. 4.3.1 Operating Area Selection To provide for a broad coverage of HONI’s service territory a total of 11 operating areas were selected: Bracebridge, Dryden, Essex, Kingston, Newmarket, Owen Sound, Perth, Peterborough, Simcoe, Sudbury, and Timmins. HONI operates across diverse terrain with a large variation in environmental, geographic, and other operating conditions. The operating areas were chosen to ensure that they represent a material cross section of the actual conditions, customers, and geography of HONI’s service territory. Figure 8 and Figure 9 illustrate the chosen operating areas and their location across the province. The operating areas selected, include three in the north, three in the southwest, three from the central part of the province, and two in the east. They include a blend of agricultural, forested, and urban areas. Furthermore, the operating areas were selected to represent diversity in terms of geology, the prevalence of storms, and overall size. 23 Non-interruptions refer to trouble calls where a work crew was dispatched but customers did not suffer a loss of power. London Economics International LLC Benjamin Grunfeld/Steven Kim [phone removed] [email removed] 16 PowerNex Associates Inc. Mark Vainberg/Gary Ford/Andrew Poray [phone removed] [email removed]Page 38 of 99
Customer Density and Distribution Service Costs Figure 8: Operating Areas Selected from Northern Ontario Source: HONI; LEI and PNXA analysis London Economics International LLC Benjamin Grunfeld/Steven Kim [phone removed] [email removed] 17 PowerNex Associates Inc. Mark Vainberg/Gary Ford/Andrew Poray [phone removed] [email removed]Page 39 of 99
Customer Density and Distribution Service Costs Figure 9: Operating Areas Selected from Southern Ontario Source: HONI; LEI and PNXA analysis London Economics International LLC Benjamin Grunfeld/Steven Kim [phone removed] [email removed] 18 PowerNex Associates Inc. Mark Vainberg/Gary Ford/Andrew Poray [phone removed] [email removed]Page 40 of 99
Customer Density and Distribution Service Costs 4.3.2 Sample Area Selection A total of 62 sample areas were selected; between four and seven from each of the 11 operating areas. In order to test the hypothesis that there is a relationship between customer density and the cost to serve customers, sample areas having three distinct customer densities were defined. This was accomplished by using sample areas of approximately the same size and by selecting areas with varying numbers of customers. The selection of sample areas did not consider the existing rate classes or density definitions. When selecting the sample areas, LEI and PNXA followed the five general guidelines listed below: each sample area should be of a similar size, approximately 20 square kilometres; low-density sample areas should have between 100 and 200 customers; medium-density sample areas should have between 700 and 1,200 customers; high-density sample areas were found around any large “urban” concentration of customers within the operating area, resulting in sample areas with typically more than 2,000 customers. sample area boundaries should be selected to minimize the impact of network structure on the calculation of the assignment factors and/or asset intensity. With respect to the last guideline, it was important to minimize the degree of judgment required to determine whether an asset served, or an outage affected, a given sample area. The above criteria were formulated and used for the initial identification of potential sample areas. Additional low-density sample areas with fewer customers (i.e., less than 100) were also included to better capture the actual variability of customer density in rural areas. The process of selecting operating areas and sample areas within them was carried out by LEI and PNXA. 4.3.3 Summary Characteristics Summary characteristics for each of the individual sample areas, including the number of customers, area, total circuit kilometres, and customer density are provided in Figure 10. The smallest sample area contained 20 customers while the largest contained over 13,000. Customer density, measured as customers per square kilometre, ranges from 0.7 to 667.9. Likewise, customer density, measured as customers per circuit kilometre, ranges for 0.4 to 79.5. Figure 11 provides a summary of the sample area characteristics, by density class (i.e., low, medium, or high). The average customer density of the low-density sample areas is 6 customers per square kilometre or 3 customers per circuit kilometre. The average customer density of the medium-density sample areas is 43 customers per square kilometre or 16 customers per circuit kilometre. The average for the high-density sample areas is 291 customers per square kilometre or 40 customers per circuit kilometre. London Economics International LLC Benjamin Grunfeld/Steven Kim [phone removed] [email removed] 19 PowerNex Associates Inc. Mark Vainberg/Gary Ford/Andrew Poray [phone removed] [email removed]Page 41 of 99
Customer Density and Distribution Service Costs Figure 10: Summary Characteristics of Individual Sample Areas 2 Circuit km Custome rs p e r km 2 Op e ra ting Are a Sa mp le Are a Numb e r of Custome rs km Bracebridge LD1 154 18.2 25.7 8.5 Custome rs p e r Circuit km 6.0 Bracebridge LD2 102 21.4 27.9 4.8 3.6 Bracebridge Bracebridge LD3 MD1 111 1,125 19.2 21.7 31.9 94.5 5.8 51.9 3.5 11.9 Bracebridge Bracebridge MD2 MD3 1,417 727 22.5 28.8 74.7 77.2 62.9 25.2 19.0 9.4 Dryden Dryden LD1 LD2 103 20 22.4 29.4 43.4 47.9 4.6 0.7 2.4 0.4 Dryden Dryden MD1 MD2 872 1,057 16.9 17.4 43.5 65.0 51.6 60.7 20.1 16.3 Dryden Essex HD1 LD1 3,608 179 22.7 22.8 106.1 38.0 158.8 7.8 34.0 4.7 Essex Essex LD2 MD1 174 886 15.0 21.0 73.9 49.4 11.6 42.2 2.4 17.9 Essex Essex MD2 HD1 912 2,279 17.9 20.9 44.7 95.1 50.9 109.2 20.4 24.0 Essex Kingston HD2 LD1 1,973 84 20.5 19.3 111.7 36.9 96.1 4.4 17.7 2.3 Kingston LD2 84 18.8 34.8 4.5 2.4 Kingston MD1 662 22.8 52.2 29.1 12.7 Kingston MD2 858 24.0 63.1 35.7 13.6 Kingston HD1 11,260 16.9 237.3 667.9 47.5 Newmarket LD1 259 17.4 56.6 14.9 4.6 Newmarket LD2 271 19.4 33.8 14.0 8.0 Newmarket LD3 164 18.5 21.7 8.9 7.6 Newmarket MD1 911 16.7 68.7 54.4 13.3 Newmarket HD1 3,593 16.5 91.2 218.1 39.4 Newmarket HD2 8,956 18.0 170.6 498.7 52.5 Newmarket HD3 8,463 17.2 168.2 492.7 50.3 Newmarket HD4 3,876 21.3 145.7 181.9 26.6 Owen Sound LD1 78 19.7 22.1 4.0 3.5 Owen Sound LD2 63 17.4 30.7 3.6 2.1 Owen Sound MD1 598 22.0 76.7 27.2 7.8 Owen Sound MD2 514 19.5 75.2 26.3 6.8 Owen Sound HD1 10,062 22.4 237.9 448.7 42.3 Perth Perth LD1 LD2 92 130 20.7 20.6 37.6 33.2 4.4 6.3 2.4 3.9 Perth Perth MD1 MD2 810 547 24.3 24.8 69.5 80.1 33.3 22.0 11.7 6.8 Perth HD1 3,811 17.5 132.4 217.5 28.8 Perth HD2 5,366 20.5 193.9 261.2 27.7 Peterborough LD1 126 24.4 64.8 5.2 1.9 Peterborough Peterborough LD2 MD1 162 949 24.7 20.1 54.7 58.9 6.6 47.2 3.0 16.1 Peterborough Peterborough MD2 MD3 1,182 1,237 20.9 23.2 71.6 63.5 56.5 53.4 16.5 19.5 Simcoe Simcoe LD1 LD2 153 128 20.9 20.5 25.2 40.3 7.3 6.2 6.1 3.2 Simcoe Simcoe MD1 MD2 938 936 24.4 13.2 54.8 17.5 38.5 70.9 17.1 53.6 Simcoe Sudbury MD3 LD1 446 137 20.0 18.2 34.9 32.2 22.3 7.5 12.8 4.3 Sudbury Sudbury LD2 MD1 90 938 19.5 22.2 30.9 57.0 4.6 42.2 2.9 16.4 Sudbury MD2 808 20.5 52.0 39.4 15.5 Sudbury HD1 4,674 21.5 106.4 217.7 43.9 Sudbury Sudbury HD2 HD3 3,361 2,032 20.3 24.2 100.2 51.4 165.7 83.9 33.5 39.5 Timmins Timmins LD1 LD2 123 39 20.9 24.2 25.8 26.8 5.9 1.6 4.8 1.5 Timmins HD1 13,057 19.7 164.2 663.5 79.5 Timmins HD2 2,983 17.4 55.1 171.1 54.1 Source: HONI; LEI and PNXA analysis By design, the average customer-per-square-kilometre densities of the sample area groupings are distinct and there is no overlap at the individual sample area level. For example, within the London Economics International LLC Benjamin Grunfeld/Steven Kim [phone removed] [email removed] 20 PowerNex Associates Inc. Mark Vainberg/Gary Ford/Andrew Poray [phone removed] [email removed]Page 42 of 99
Customer Density and Distribution Service Costs medium-density sample area group the lowest density is approximately 22 customers per square kilometre, whereas within the low-density sample area group the highest density is approximately 15 customers per square kilometre. Likewise within the high-density sample area group the lowest density is approximately 83 customers per square kilometre compared to 71 customers per square kilometre, which is the highest density within the medium-density sample area group. Figure 11: Summary Characteristics of All Sample Areas Low Density Medium Density High Density Numb e r of Custome rs Ave ra ge St. De v 126 59 879 240 5,585 3,567 Are a (Sq ua re Kilome tre s) Ave ra ge St. De v 21 3 21 3 20 2 Customers p er Sq ua re Kilometre Avera ge St. Dev 6 4 Low Density Medium Density High Density 43 291 Circuit Kilome tre s Ave ra ge St. De v 37 14 61 17 135 57 Customers p er Circuit Kilometre Avera ge St. Dev 3 2 14 197 16 40 9 15 Source: HONI; LEI and PNXA analysis The average customer per-circuit-kilometre densities of the sample area groupings are also distinct. However, there is some overlap at the individual sample area level. Out of 61 sample areas, three overlap.24 Two low-density sample areas have a density of more than 6.8 customers per circuit kilometre, which is the lowest density of the medium-density sample areas. Only one high-density sample area has a density of less than 20.4 customers per square kilometre, which is the highest density of the medium-density sample areas. Figure 12: Summary Characteristics of 11 Operating Areas in Study Op e ra ting Are a Numb e r of Custome rs km 2 Circuit km Custome rs Bracebridge Dryden Essex Kingston Newmarket Owen Sound Perth Peterborough Simcoe Sudbury Timmins 19,382 12,245 34,293 48,240 49,876 46,770 38,821 38,359 15,517 33,969 22,517 3,014 101,121 1,939 3,019 1,486 4,749 4,368 4,024 3,596 7,034 20,004 2,481 1,758 2,663 3,578 3,098 4,801 4,207 5,046 2,003 2,724 1,646 6.4 0.1 17.7 16.0 33.6 9.8 8.9 9.5 4.3 4.8 1.1 p e r km 2 Custome rs p e r Circuit km % Wood e d Are a % Wa te r Are a 7.8 7.0 12.9 13.5 16.1 9.7 9.2 7.6 7.7 12.5 13.7 76% 65% 6% 42% 30% 44% 54% 36% 19% 72% 94% 16% 17% 3% 13% 1% 5% 9% 9% 4% 11% 5% Source: HONI; LEI and PNXA analysis 24 This excludes one outlying medium density sample area in the Simcoe operating area, which has a disproportionately small amount of distribution circuitry relative to the other medium density sample areas. London Economics International LLC Benjamin Grunfeld/Steven Kim [phone removed] [email removed] 21 PowerNex Associates Inc. Mark Vainberg/Gary Ford/Andrew Poray [phone removed] [email removed]Page 43 of 99
Customer Density and Distribution Service Costs This differentiation between the sample areas groups (i.e. the lack of high-, medium-, and lowdensity sample areas with overlapping customer densities) contributes to the robustness of the study by limiting boundary concerns. Figure 12 provides the same data as Figure 11, but for each of the 11 operating areas as a whole. As evident, the selected operating areas reflect a broad range of defining characteristics, including size, total circuit length, density, wood cover, and water cover. 4.4 Calculating Assignment Factors A total of seven distinct assignment factors were developed. A brief description of each assignment factor is provided below and the detailed method for determining the assignment factors is provided in Appendix C. In addition to the individual assignment factors, LEI and PNXA used combined factors. The combined factors were calculated by multiplying individual assignment factors. Customer Ratio across Entire HONI Service Territory (“CRT”) This assignment factor represents the proportion of the total number of HONI customers across the entire service territory contained within an individual sample area. It is used to assign certain provincial-level OM&A costs. Customer Ratio within each Operating Area (“CROA”) This assignment factor represents the proportion of the total number of HONI customers in a given operating area contained within an individual sample area. It is used to assign certain operating area OM&A costs. Customer Distance Ratio (“CDR”) This ratio represents the total distance to the customers in a sample area relative to the total distance to all customers in the operating area. The purpose of this ratio was to assign operating area level OM&A costs to customers in each sample area, recognizing that work crews typically have to travel some distance to customer locations to carry out specific tasks. The ratio is based on “straight-line” distances between customers and the closest service centre, which is an approximation of the actual time it takes for a work crew to reach a given customer. Underground Conductor Ratio (“UGR”) The purpose of this ratio was to assign operating area level OM&A costs related to underground cables. It represents the proportion of the kilometres of underground cable in a sample area relative to the total operating area. Pole Distance Ratio (all poles) (“PDRT”) This ratio represents the total distance to the poles in a sample area relative to the total distance to all poles in the operating area. The purpose of this ratio was to assign asset related operating area level OM&A costs to each sample area, recognizing that crews typically have to travel London Economics International LLC Benjamin Grunfeld/Steven Kim [phone removed] [email removed] 22 PowerNex Associates Inc. Mark Vainberg/Gary Ford/Andrew Poray [phone removed] [email removed]Page 44 of 99
Customer Density and Distribution Service Costs some distance to get to an asset to carry out specific tasks. Examples of this would include repairing or replacing poles or conductor after storm damage. Similar to the customer distance ratio, this assignment factor is based on the straight-line distance between an asset and the service center as an approximation for the time it takes a work crew to reach an asset. LEI and PNXA performed a sensitivity analysis to determine whether straight-line distance was a reasonable approximation for estimated driving time. The results of this analysis are provided in Section 4.9. Interruption Ratio Non- Storms (“IRNS”) The purpose of this ratio was to assign operating area level trouble call related work program costs that are non-storm related. It represents the proportion of non-storm related trouble calls (interruptions and non-interruptions) in an operating area that relate to an individual sample area. Interruption Ratio Storms (“IRS”) The purpose of this ratio was to assign operating area level trouble call related work program costs that are storm related. It reflects the proportion of storm related trouble calls (interruptions and non-interruptions) in an operating area that relate to an individual sample area. Detailed calculation methodologies as well as the specific sample area assignment factors are provided in Appendix C. It should be noted that 2010 data (customer counts, asset counts, replacement costs) was used to develop the assignment factors, with the exception of interruption ratios, which were calculated for each specific year based on the interruption/noninterruption data for that year. 4.5 Direct Assignment of OM&A Costs OM&A costs were directly assigned to individual sample areas on the basis of the assignment factors discussed above. The direct cost assignment analysis focused primarily on OM&A expenses related to sustainment activities. Sustainment activities include distribution line maintenance, distribution station maintenance, and vegetation management. Sustainment activities represented approximately 57 percent of HONI’s estimated 2010 OM&A expenditure.25 The OM&A costs that were included in the direct cost assignment analysis provide a reasonable basis for assessing whether there is a relationship between distribution service costs and customer density. The balance of the OM&A costs are customer care, shared services, operations, and development related, and as such are generally not expected to vary on a percustomer basis with density. However, as described in Section 5, it is necessary to take these 25 HONI. “Cost of Service Summary: Exhibit C1, Tab 1, Schedule 1 (EB-2009-0096)”. September 2009. London Economics International LLC Benjamin Grunfeld/Steven Kim [phone removed] [email removed] 23 PowerNex Associates Inc. Mark Vainberg/Gary Ford/Andrew Poray [phone removed] [email removed]
Text of CIEC-20 (d) Attachment 1 - PG&E Rate B-20.pdf
Extracted from the file · 24 pages · 63,774 characters
Text of CIEC-20 (d) Attachment 2 - PSCo Schedule PG.pdf
Extracted from the file · 3 pages · 7,608 characters
As listed on the current system
Question(s) Answered 2 thru 20 (OCC) Date Filed: 11/12/2026