Interrogatory responses
Answers to questions 2 thru 20
Files10
OCC Response to CIEC Second Set of Requests.pdf
PDF · 571 KB · 25 pagesText searchable
Download OCC Response to CIEC Second Set of Requests.pdfRead the text of OCC Response to CIEC Second Set of Requests.pdf
Response to CIEC-2 (a) Classification of AMI-related costs.xlsx
Excel · 16 KBText searchable
Download Response to CIEC-2 (a) Classification of AMI-related costs.xlsxRead the text of Response to CIEC-2 (a) Classification of AMI-related costs.xlsx
Response to CIEC-8 (b) Allocation of AMI meter costs.xlsx
Excel · 16 KBText searchable
Download Response to CIEC-8 (b) Allocation of AMI meter costs.xlsxRead the text of Response to CIEC-8 (b) Allocation of AMI meter costs.xlsx
CIEC-9 (d) Attachment A C17-0556_16A-0588E.pdf
PDF · 177 KB · 16 pagesText searchable
Download CIEC-9 (d) Attachment A C17-0556_16A-0588E.pdfRead the text of CIEC-9 (d) Attachment A C17-0556_16A-0588E.pdf
CIEC-9 (d) Attachment B 2023-CO-Phase-II-Electric-Rate-Review-Decision.pdf
PDF · 476 KB · 45 pagesText searchable
Download CIEC-9 (d) Attachment B 2023-CO-Phase-II-Electric-Rate-Review-Decision.pdfRead the text of CIEC-9 (d) Attachment B 2023-CO-Phase-II-Electric-Rate-Review-Decision.pdf
CIEC-12 Attachment - Bonbright Excerpt.pdf
PDF · 136 KB · 4 pagesText read by machine from a scan; may contain errors, especially in numbers
Download CIEC-12 Attachment - Bonbright Excerpt.pdfScanned pages and text of CIEC-12 Attachment - Bonbright Excerpt.pdf
CIEC-13 (a) Attachment - rate_order_Hydro One DX 2013_20121220.pdf
PDF · 245 KB · 31 pagesText searchable
Download CIEC-13 (a) Attachment - rate_order_Hydro One DX 2013_20121220.pdfRead the text of CIEC-13 (a) Attachment - rate_order_Hydro One DX 2013_20121220.pdf
CIEC-13 (d) - Hydro One Density Study HONI_APPL_Exhibit D_20120615.pdf
PDF · 3.3 MB · 99 pagesText searchable
Download CIEC-13 (d) - Hydro One Density Study HONI_APPL_Exhibit D_20120615.pdfRead the text of CIEC-13 (d) - Hydro One Density Study HONI_APPL_Exhibit D_20120615.pdf
CIEC-20 (d) Attachment 1 - PG&E Rate B-20.pdf
PDF · 1.9 MB · 24 pagesText searchable
Download CIEC-20 (d) Attachment 1 - PG&E Rate B-20.pdfRead the text of CIEC-20 (d) Attachment 1 - PG&E Rate B-20.pdf
CIEC-20 (d) Attachment 2 - PSCo Schedule PG.pdf
PDF · 198 KB · 3 pagesText searchable
Download CIEC-20 (d) Attachment 2 - PSCo Schedule PG.pdfRead the text of CIEC-20 (d) Attachment 2 - PSCo Schedule PG.pdf
Text of CIEC-9 (d) Attachment A C17-0556_16A-0588E.pdf
Extracted from the file · 16 pages · 28,745 characters
Text of CIEC-9 (d) Attachment B 2023-CO-Phase-II-Electric-Rate-Review-Decision.pdf
Extracted from the file · 45 pages · 89,290 characters
Scanned pages of CIEC-12 Attachment - Bonbright Excerpt.pdf
Read by machine from a scan · 4 pages · may contain errors, especially in numbers
Text of CIEC-13 (a) Attachment - rate_order_Hydro One DX 2013_20121220.pdf
Extracted from the file · 31 pages · 41,898 characters
Page 49 of 99
Customer Density and Distribution Service Costs Figure 17: Distribution of per-customer Assigned Sample Area OM&A Costs 80% 70% 60% 50% 40% 30% 20% 10% OM&A Cost per Customer 1000 950 900 800 50,000 850 750 47,500 700 650 600 550 500 450 400 350 HD 300 250 MD 200 150 LD 100 50 0% Source: LEI and PNXA analysis Figure 18: Distribution of Asset Intensity Results 60% 50% 40% 30% 20% 10% LD MD HD 65,000 62,500 60,000 57,500 55,000 52,500 45,000 42,500 40,000 37,500 35,000 32,500 30,000 27,500 25,000 22,500 20,000 17,500 15,000 12,500 10,000 7,500 5,000 2,500 0 0% Asset Intensity per Customer Source: LEI and PNXA analysis The t-test was used to determine if the distributions of the low-, medium-, and high-density sample area results could have come from the same underlying population or not, and with what confidence a conclusion could be stated. The calculation was carried out with the hypothesis that the two sample area result distributions were drawn from the same underlying population. When the t-test was applied to the low-density and medium-density OM&A results, at the 99 percent confidence level the t-statistic was 3.014. This implies that the probability of the London Economics International LLC Benjamin Grunfeld/Steven Kim [phone removed] [email removed] 28 PowerNex Associates Inc. Mark Vainberg/Gary Ford/Andrew Poray [phone removed] [email removed]Page 50 of 99
Customer Density and Distribution Service Costs hypothesis being true was 0.0060 on a two tail or absolute value basis, and 0.0030 on a one tail basis. Hence, when comparing these two distributions it can be concluded, with 99 percent confidence, that the two distributions are drawn from two underlying populations that are different and that have different mean values. Similar results were obtained when comparing the medium-density and high-density OM&A results and for all the asset intensity results. Therefore although these three distributions appear to overlap, as illustrated in the figures above, the t-test reveals that all three of the distributions are drawn from different underlying populations. Figure 19: Summary of Statistical Analysis Low versus Medium Medium versus High t-Sta t OM&A 1 T a il 2 T a il t-Sta t 3.0140 5.1275 0.0030 0.0000 0.0060 0.0000 7.3518 6.6359 Asse t Inte nsity 1 T a il 2 T a il 0.0000 0.0000 0.0000 0.0000 Note: Results rounded to 4 decimal places Source: LEI and PNXA analysis Hence, the results of the direct cost assignment analysis demonstrate that there is a statistically significant inverse relationship between customer density and the cost to serve distribution system customers. 4.8 Impact of Very Low Customer Density In the direct cost assignment analysis, the low-density sample areas were chosen with varying distances from a service centre and typically 100 to 200 customers, although some sample areas with as few as 20 customers were also considered. However, in some of the larger operating areas there are sparsely populated areas that are both a substantial distance away from a service centre and have far fewer customers. Based on the selection criteria presented above in Section 4.3, such remote and sparsely populated areas were avoided. However, to get a sense of the costs associated with serving HONI’s more remote customers, a very low-density sample area was analyzed. The sample area, located in the Dryden operating area, was not included in the results of the direct cost analysis because of the extremely low customer density. The sample area contains a total of three customers and has an area of 21.4 square kilometres, which is close to the notional 20 square kilometres used for the rest of the sample areas in this study. The costs per customer for this sample area have been calculated using the same methodology as for the rest of sample areas, and are presented below in Figure 20. Figure 20: Per-customer Results for Very Low Density Sample Area OM&A Asse t Inte nsity Very Low Density ("VLD") Sample Area 4,574 368,467 Average of all Low Density Sample Areas (excluding VLD) 379 27,925 Maximum of all Low Density Sample Areas (excluding VLD) 1,868 61,279 Ratio VLD to Average of all Low Density Sample Areas 12 13 Ratio of VLD to Max of all Low Density Sample Areas 2 6 Source: LEI and PNXA analysis London Economics International LLC Benjamin Grunfeld/Steven Kim [phone removed] [email removed] 29 PowerNex Associates Inc. Mark Vainberg/Gary Ford/Andrew Poray [phone removed] [email removed]Page 51 of 99
Customer Density and Distribution Service Costs The results clearly show that both the OM&A costs and the asset intensity per customer are significantly higher than the rest of the sample areas analyzed. The asset intensity is approximately six times greater than the maximum of all of the low-density sample areas. The OM&A cost per customer is approximately twice the maximum of all of the low-density sample areas. These results demonstrate that if wider selection criteria for the low-density samples areas were adopted, the mean and the standard deviation of the low-density sample area results likely would have been higher. 4.9 Driving Time versus Straight-line Distance One of the assumptions in the direct cost assignment method is that some of HONI’s OM&A expenses are proportional to the distance from the customer (or asset) to the closest service centre. Costs relating to trouble calls, pole maintenance, patrol and inspection, etc. were all assigned using distance from the customers to the service center, or distance from the pole to the service center. All of the assignment factors used a “straight-line” or as the “crow flies” distance based on coordinates obtained from the GIS. Depending on the roads, weather, traffic conditions and work location scheduling, the driving time to and from customers or to and from equipment can change significantly. To test the sensitivity of the results to this approach, LEI and PNXA re-estimated the results for one operating area using assignment factors based on estimates of “drive time” as opposed to straight-line distance. The operating area that was selected for the sensitivity was Bracebridge. With all the lakes in the Bracebridge operating area it was thought that this would represent the extreme in terms of the difference between driving time and straight-line distance. As illustrated in Figure 21, the use of driving time instead of straight-line distance has a marginal impact on the results of the assignment of OM&A costs. There does not appear to be a uniform or consistent relationship between the impact on the results and the density of the sample areas. Furthermore the results of this sensitivity illustrate that while some assigned sample area costs might increase if straight-line distance was replaced with driving time, others of like density could decrease. Hence, the use of straight-line distance for allocating costs appears to be reasonable. London Economics International LLC Benjamin Grunfeld/Steven Kim [phone removed] [email removed] 30 PowerNex Associates Inc. Mark Vainberg/Gary Ford/Andrew Poray [phone removed] [email removed]Page 52 of 99
Customer Density and Distribution Service Costs Figure 21: Percent Change in Directly Assigned per-customer OM&A Costs 10% 8% 6% 4% 2% 0% -2% -4% LD1 LD2 LD3 MD1 MD2 MD3 Source: LEI and PNXA analysis London Economics International LLC Benjamin Grunfeld/Steven Kim [phone removed] [email removed] 31 PowerNex Associates Inc. Mark Vainberg/Gary Ford/Andrew Poray [phone removed] [email removed]Page 53 of 99
Customer Density and Distribution Service Costs 5 HONI’s Current Tariff Design In general, distribution utility tariff (or rate) design consists of three steps: calculating the revenue requirement, determining rate classes and allocating appropriate costs to them, and formulating a structure for the tariffs. Figure 22: Components of Standard Distribution Tariff Design REVENUE REQUIREMENT • O&M Costs • Return on Rate Base • Depreciation • Taxes RATE CLASS STRUCTURE TARIFF STRUCTURE • Type of classes • Demarcation points • Cost allocation factors • Billing determinants • Fixed charges • Volumetric charges TARIFFS The analysis presented in this report offers insights into the appropriateness and reasonableness of the rate class structure component of HONI’s existing tariff design. The analysis undertaken was not intended to nor does it allow for any direct inference to be drawn as to the appropriateness and reasonableness of the revenue requirement or tariff structure components. There are three elements to HONI’s existing rate class structure to consider: the number and type of rate classes that are utilized; the demarcation points between the various rate classes; and the cost allocation factors that assign costs to the different classes. HONI has a total of 12 rate classes. A three-step segmentation process is used to classify distribution customers. The first level of segmentation is based on the category of customer: residential, commercial/industrial (i.e., general service), or other. The second level of segmentation is based on the functionality of service: energy billed or demand billed for general service customers; and primary or non-primary occupancy for residential customers. Finally, the third level of segmentation involves classification based on customer density. HONI defined three levels of density for year-round residential customers and two levels of density for general service customers. All seasonal customers are placed within the same rate class with its own average density. London Economics International LLC Benjamin Grunfeld/Steven Kim [phone removed] [email removed] 32 PowerNex Associates Inc. Mark Vainberg/Gary Ford/Andrew Poray [phone removed] [email removed]Page 54 of 99
Customer Density and Distribution Service Costs Figure 23: Structure of HONI’s Current Distribution Rate Classes T ype of Customer HONI Density Le vel T ype of Service PRIMARY OCCUPANCY RESIDENTIAL NON-PRIMARY OCCUPANCY HIGH UR MEDIUM R1 LOW R2 ALL SEAS UGe HIGH ENERGY BILLED MEDIUM/LOW COMMERCIAL / INDUSTRIAL DEMAND BILLED OTHER ALL R a te Class GSe HIGH UGd MEDIUM/LOW GSd ALL St Lgt, Sen Ltg, DGEN, ST Demarcation points are established to facilitate the segmentation of customers based on density. Currently, an “urban” zone (consisting of the UR, UGe, or UGd rate classes) is defined to be an area containing more than 3,000 total customers and having a line density of at least 60 customers per circuit kilometre. General Service customers outside of an urban zone are all classified as non-urban and segmented into the GSe or GSd rate classes. For year-round residential customers, there is an intermediate density level (consisting of the R1 rate class) defined to be areas containing more than 100 total customers and having a density of at least 15 customers per circuit kilometre. Finally, the remaining year-round residential customers are segmented into the lower density R2 rate class. The OEB’s distribution CAM establishes a province-wide approach to allocating costs to the individual rate classes. HONI has modified the CAM to take into account customer density segmentation. This modification includes establishing new rate classes as well as incorporating density weighting factors to assign costs to the individual rate classes. Details of the modifications HONI has made to the CAM are available on HONI’s website. An extract of the discussion from HONI’s 2010/2011 distribution rate application is provided in the text box below. London Economics International LLC Benjamin Grunfeld/Steven Kim [phone removed] [email removed] 33 PowerNex Associates Inc. Mark Vainberg/Gary Ford/Andrew Poray [phone removed] [email removed]Page 55 of 99
Customer Density and Distribution Service Costs Density Weighting Factors - Excerpts from HONI 2010/2011 Rate Application “Density factors have been incorporated as weighting factors for overhead lines and transformer related costs.” “For lines, customer density weighting factors were developed by calculating for all feeders the number of customers by customer class on each feeder and assigning the total distance of the feeders to the various customer classes proportionally. A similar method was used to develop demand density weighting factors, by using energy by customer class by feeder and total energy supplied by feeder to assign the feeder length for each feeder to customer classes proportionally.” “For transformers, customer density weighting factors were developed by calculating net book value of transformation assets by feeder and assigning the total net book value of transformation assets by feeder to the various customer classes proportionally. A similar method was used to develop demand density weighting factors, by using energy by customer class by feeder and total energy supplied by feeder to assign the net book value of transformation assets for each feeder to customer classes proportionally.” Source: HONI 2010/2011 Distribution Rate Application (EB-2009-0096), Application and Pre-filed Evidence, Exhibit G2, Tab 1, Schedule 1. To fulfill the second objective of this study, as defined in Section 1.1, this chapter of the report discusses each of the three components of HONI’s rate class structure identified above in the context of the analysis and results presented in previous chapters. 5.1 Rate Classes and Demarcations 5.1.1 Density as a Differentiator Question: Is it reasonable to have rate classes that are differentiated by customer density? One of the principal objectives when defining rate classes is to ensure “fairness of the specific rates in the apportionment of total costs of service among different ratepayers so as to avoid arbitrariness and capriciousness and to attain equity”.28 Of particular relevance to this study, are the concepts of “horizontal equity” (i.e., equals treated equally) and “vertical equity” (i.e., non-equals treated unequally). The first objective of the study, to evaluate the relationship between customer density and distribution service costs, is in effect asking the question of whether or not customers with dissimilar densities are unequal with respect to the costs incurred by HONI to serve them. The results of the econometric and direct cost assignment analysis demonstrate that the cost to serve customers of different “densities” is in fact different. As such, in keeping with costcausation principles it appears reasonable for HONI to use rate classes that are differentiated based on customer density. 28 Bonbright, James C., Alberta L. Danielson and David R. Kamerschen. The Principles of Public Utility Rates (Second Edition). Public Utilities, Inc.,1988. Print. pp 383-384. London Economics International LLC Benjamin Grunfeld/Steven Kim [phone removed] [email removed] 34 PowerNex Associates Inc. Mark Vainberg/Gary Ford/Andrew Poray [phone removed] [email removed]Page 56 of 99
Customer Density and Distribution Service Costs 5.1.2 Number of Density-based Rate Classes Question: How many density-based rate classes (e.g., high, medium, and low vs. high and low, etc.) are reasonable? HONI currently has three density-differentiated rate classes for year-round residential customers and two density-differentiated rate classes for general service customers. While neither the econometric nor the direct cost assignment analyses are able to directly address this question, the results offer some insights. As discussed in Section 4.7, the direct cost assignment analysis has shown that there are statistically significant differences between the mean assigned costs for the high-, medium-, and low-density sample areas. Based on this evidence it is reasonable to conclude that three density differentiated rate classes (a low, medium, and high) appears justified. Selecting the appropriate number of rate classes requires a careful balance between minimizing the degree of cross subsidisation and maintaining a reasonable number of customers in each class. Given that HONI has substantially fewer general service customers (~110,000) when compared to the number of residential customers (~1,100,000), limiting the number of densitybased general service rate classes to two is reasonable. Figure 24 below illustrates the relationship between the per-customer assigned OM&A costs and customer density (measured by the number of customers per square kilometre) for the sample areas. Similarly, Figure 25 shows the relationship between the per-customer asset replacement costs and customer density for the sample areas. The two graphics reveal similar patterns, the variability of the estimated sample area assigned cost decreases as density increases. The results yield the same conclusions when considering density based on the number of customers per circuit kilometre, as shown in Figure 60 and Figure 61 in Appendix C. The variability of the assigned costs within a given density group (high, medium, low) can be taken to represent the degree of cross-subsidisation that potentially exists. Variability in the assigned costs is representative of the range of costs associated with serving individual customers in a group or class. As the range increases, or widens, the average cost to serve may remain constant, however, the low-cost customers provide a larger subsidy to the high-cost customers. Conversely, as the range decrease, or tightens, the subsidy diminishes. As illustrated by Figure 24 and Figure 25, there is only a small variation in the estimated cost to serve sample areas when customer density is above 100 customers per square kilometre. While there is more variability across the medium-density sample areas than across the high-density sample areas, this level of variability is still rather limited. London Economics International LLC Benjamin Grunfeld/Steven Kim [phone removed] [email removed] 35 PowerNex Associates Inc. Mark Vainberg/Gary Ford/Andrew Poray [phone removed] [email removed]Page 57 of 99
Customer Density and Distribution Service Costs Figure 24: Relationship between per-customer Assigned OM&A Costs and Customer Density OM&A Cost ($) per Customer 2,000 1,800 1,600 1,400 1,200 1,000 800 600 400 200 LD 0 MD HD 200 400 600 Customers per Square Kilometre 800 Source: LEI and PNXA analysis Figure 25: Relationship between per-customer Asset Replacement Cost and Customer Density 60,000 50,000 Customer Asset Replacement Cost ($) per 70,000 40,000 30,000 20,000 10,000 - 0 LD MD HD 200 400 600 800 Customers per Square Kilometre Source: LEI and PNXA analysis There is considerably more variability in the assigned costs for the low-density sample areas. This suggests that there may be a greater degree of cross subsidization within low-density rate classes. One possible way to minimize the degree of cross subsidization would be to introduce additional low-density rate classes. While creating additional rate classes may reduce potential cross subsidies within the lowdensity rate classes, there are other factors that need to be considered. Cost allocation is a zerosum game, hence if one rate goes down another must go up to balance the total revenue London Economics International LLC Benjamin Grunfeld/Steven Kim [phone removed] [email removed] 36 PowerNex Associates Inc. Mark Vainberg/Gary Ford/Andrew Poray [phone removed] [email removed]Page 58 of 99
Customer Density and Distribution Service Costs generated. Cost allocation is rarely perfect, and some degree of cross subsidization within a rate class is also to be expected. These factors need to be taken into account when considering measures to reduce potential cross subsidies within HONI’s current rate classes. Overall, however, based on the results of this study, there does not appear to be an immediate or pressing need to change the number of existing density-based rate classes. 5.1.3 Demarcation Points Question: What should form the cut-off point between the density-based rate classes? The study was not specifically designed to address this question. As such additional data and analysis would be required to conclusively determine the reasonableness of HONI’s existing demarcation points or determine alternatives. It should be noted however, that the study did not provide strong evidence to support changing the existing demarcation points. While minor adjustments could be made, there are costs and benefits associated with such a transition. HONI’s current demarcation rules allow for interpretation, in particular when determining the specific geographic boundary between two rates classes. This has led to some discussion around the use of municipal or other political boundaries, which are “better” defined and understood by customers. The issue of alternate rate classes and demarcations is discussed in additional detail in Section 6. 5.2 Cost Allocation Factors Question: Do HONI’s existing density weighting factors accurately reflect the relationship between customer density and cost of service, as reflected in this study? To judge the reasonableness of the existing density weighting factors, LEI and PNXA compared the overall outcome of HONI’s CAM to the results of the direct cost assignment analysis.29 Figure 26 summarizes the results of the CAM used by HONI in its 2010/2011 distribution rate application. The costs allocated to the UR class are equivalent to $419 per customer, whereas the costs allocated to the R1 and R2 classes are equivalent to $663 and $1,176 per customer, respectively. The costs allocated to the Seasonal residential class are $612 per customer, slightly lower than the per-customer cost allocated to R1 customers. The per-customer costs allocated to the GSe and GSd rate classes are higher than those assigned to the UGe and UGd rate classes. 29 The results of the econometric analysis (i.e. the estimated coefficients) can be used to predict the cost to serve groups of customers of different densities. This is done by inputting values for the parameters in the cost function and calculating the predicted cost based on the formula. However, LEI and PNXA concluded that utilizing the results of the econometrics for the purpose of establishing the reasonableness of HONI’s existing cost allocation factors was not feasible. In order to utilize the econometric results to answer this question, a discrete average customer density would have to be established for each rate class. In order to do this, the geographic areas associated with each rate class would have to be established and measured. The length of conductor in that geographic area would also have to be calculated. HONI’s GIS does not currently contain this information, as the geographic boundaries between the rate classes are not necessarily well defined. This is particularly true for the R1 and R2 year-round residential classes and for the Seasonal rate class. London Economics International LLC Benjamin Grunfeld/Steven Kim [phone removed] [email removed] 37 PowerNex Associates Inc. Mark Vainberg/Gary Ford/Andrew Poray [phone removed] [email removed]
Text of CIEC-20 (d) Attachment 1 - PG&E Rate B-20.pdf
Extracted from the file · 24 pages · 63,774 characters
Text of CIEC-20 (d) Attachment 2 - PSCo Schedule PG.pdf
Extracted from the file · 3 pages · 7,608 characters
As listed on the current system
Question(s) Answered 2 thru 20 (OCC) Date Filed: 11/12/2026