Interrogatory responses
Answers to questions 2 thru 20
Files10
OCC Response to CIEC Second Set of Requests.pdf
PDF · 571 KB · 25 pagesText searchable
Download OCC Response to CIEC Second Set of Requests.pdfRead the text of OCC Response to CIEC Second Set of Requests.pdf
Response to CIEC-2 (a) Classification of AMI-related costs.xlsx
Excel · 16 KBText searchable
Download Response to CIEC-2 (a) Classification of AMI-related costs.xlsxRead the text of Response to CIEC-2 (a) Classification of AMI-related costs.xlsx
Response to CIEC-8 (b) Allocation of AMI meter costs.xlsx
Excel · 16 KBText searchable
Download Response to CIEC-8 (b) Allocation of AMI meter costs.xlsxRead the text of Response to CIEC-8 (b) Allocation of AMI meter costs.xlsx
CIEC-9 (d) Attachment A C17-0556_16A-0588E.pdf
PDF · 177 KB · 16 pagesText searchable
Download CIEC-9 (d) Attachment A C17-0556_16A-0588E.pdfRead the text of CIEC-9 (d) Attachment A C17-0556_16A-0588E.pdf
CIEC-9 (d) Attachment B 2023-CO-Phase-II-Electric-Rate-Review-Decision.pdf
PDF · 476 KB · 45 pagesText searchable
Download CIEC-9 (d) Attachment B 2023-CO-Phase-II-Electric-Rate-Review-Decision.pdfRead the text of CIEC-9 (d) Attachment B 2023-CO-Phase-II-Electric-Rate-Review-Decision.pdf
CIEC-12 Attachment - Bonbright Excerpt.pdf
PDF · 136 KB · 4 pagesText read by machine from a scan; may contain errors, especially in numbers
Download CIEC-12 Attachment - Bonbright Excerpt.pdfScanned pages and text of CIEC-12 Attachment - Bonbright Excerpt.pdf
CIEC-13 (a) Attachment - rate_order_Hydro One DX 2013_20121220.pdf
PDF · 245 KB · 31 pagesText searchable
Download CIEC-13 (a) Attachment - rate_order_Hydro One DX 2013_20121220.pdfRead the text of CIEC-13 (a) Attachment - rate_order_Hydro One DX 2013_20121220.pdf
CIEC-13 (d) - Hydro One Density Study HONI_APPL_Exhibit D_20120615.pdf
PDF · 3.3 MB · 99 pagesText searchable
Download CIEC-13 (d) - Hydro One Density Study HONI_APPL_Exhibit D_20120615.pdfRead the text of CIEC-13 (d) - Hydro One Density Study HONI_APPL_Exhibit D_20120615.pdf
CIEC-20 (d) Attachment 1 - PG&E Rate B-20.pdf
PDF · 1.9 MB · 24 pagesText searchable
Download CIEC-20 (d) Attachment 1 - PG&E Rate B-20.pdfRead the text of CIEC-20 (d) Attachment 1 - PG&E Rate B-20.pdf
CIEC-20 (d) Attachment 2 - PSCo Schedule PG.pdf
PDF · 198 KB · 3 pagesText searchable
Download CIEC-20 (d) Attachment 2 - PSCo Schedule PG.pdfRead the text of CIEC-20 (d) Attachment 2 - PSCo Schedule PG.pdf
Text of CIEC-9 (d) Attachment A C17-0556_16A-0588E.pdf
Extracted from the file · 16 pages · 28,745 characters
Text of CIEC-9 (d) Attachment B 2023-CO-Phase-II-Electric-Rate-Review-Decision.pdf
Extracted from the file · 45 pages · 89,290 characters
Scanned pages of CIEC-12 Attachment - Bonbright Excerpt.pdf
Read by machine from a scan · 4 pages · may contain errors, especially in numbers
Text of CIEC-13 (a) Attachment - rate_order_Hydro One DX 2013_20121220.pdf
Extracted from the file · 31 pages · 41,898 characters
Page 67 of 99
Customer Density and Distribution Service Costs requirement and customer demands served by the four transmission companies.35 This methodology has been successfully applied since the opening of the electricity market in 2002. Figure 32: Summary of a Regional Rate Mechanism Individual Revenue Requirement Rate Classes Individual Revenue Received LDC 1 Residential LDC 1 Urban LDC 2 Combined Revenue Requirement LDC 3 Rural General Service Urban Rural Other Combined Revenue LDC 2 LDC 3 Based on percent of total revenue requirement attributed to individual utility The rate classes could also be established to maintain differences between urban and rural (high- and low-density) customers. Again a precedent exists in the electricity transmission sector where there are separate rates for connection, transformation, and network services. As an example, there are seven LDCs, including HONI that currently serve customers in the Niagara region. Hence, residential customers in this relatively small geographic region could have one of nine different rates (three possible rates for HONI customers and one each for customers in the other six utility’s service territories. Harmonizing the rates would be a simplification for consumers. It may also promote further rationalization in terms of the number of LDCs that exist within the province. 35 OEB. “In the matter of an application by: Hydro One Networks, Inc. 2011 and 2012 Transmission Revenue Requirement and Rates”. (EB-2010-0002). Toronto: December 23, 2010. London Economics International LLC Benjamin Grunfeld/Steven Kim [phone removed] [email removed] 46 PowerNex Associates Inc. Mark Vainberg/Gary Ford/Andrew Poray [phone removed] [email removed]Page 68 of 99
Customer Density and Distribution Service Costs Figure 33: LDCs in the Niagara Region Niagara Peninsula Energy Inc. Horizon Utilities Corp. Niagara-on-the Lake Hydro Inc. Welland Hydro-Electric System Corp. Grimsby Power Inc. Hydro One Networks Inc. Canadian Niagara Power Co. Ltd. Source: IESO As in most instances of rate re-design, administrative simplicity comes at the cost of allocative efficiency. In the case of a move from LDC-specific to regional distribution rates, customers that were historically in the lower-cost LDCs’ service territories could end up subsidizing customers in the higher-cost LDCs’ service territories. This may make it more difficult to achieve consensus amongst LDCs with respect to support for a move towards regional distribution tariffs. London Economics International LLC Benjamin Grunfeld/Steven Kim [phone removed] [email removed] 47 PowerNex Associates Inc. Mark Vainberg/Gary Ford/Andrew Poray [phone removed] [email removed]Page 69 of 99
Customer Density and Distribution Service Costs 7 Conclusions and Recommendations As outlined in Section 1.1, the objectives of this study were to (i) evaluate the relationship between customer density and distribution service costs, (ii) assess whether HONI’s existing density based rate classes and density weighting factors appropriately reflect this relationship, and (iii) consider, qualitatively, the appropriateness and feasibility of establishing alternate customer class definitions. Both the econometric analysis and the direct cost assignment analysis establish that there is a statistically significant inverse relationship between customer density and distribution service costs across HONI’s service territory. In both studies, distribution service costs were shown to decrease as the customer density of an operating area and/or a sample area increased. The comparison of the output from the HONI CAM with the results of the direct cost assignment analysis suggests that HONI’s existing density based rate classes and density weighting factors reflect this relationship, although the density weighting factors may understate the actual difference between the cost to serve high-, medium-, and low-density customers. Based on the results of this analysis, LEI and PNXA would not recommend wholesale changes to HONI’s existing rate class definitions. However, adjustments to the weighting factors used in HONI’s CAM could be justified to better capture the differences between the cost to serve high-, medium-, and low-density customers. In doing so, care will need to be taken to ensure that customers do not experience a sense of “rate shock”. If the resulting change in rates is significant, a transition period over which the modification is gradually introduced may be required. Other rate class definitions were also considered (i.e., municipal boundaries or regional rates), however, the move to such a design is a long-term decision that LEI and PNXA recommend be made in the context of a broader provincial dialogue. London Economics International LLC Benjamin Grunfeld/Steven Kim [phone removed] [email removed] 48 PowerNex Associates Inc. Mark Vainberg/Gary Ford/Andrew Poray [phone removed] [email removed]Page 70 of 99
Customer Density and Distribution Service Costs Appendix A –Econometric Analysis Details Introduction to Econometric Analysis If one hypothesized that distribution service costs were linearly influenced by the number of customers and customer density, Equation 3 below would be the functional form. The parameter (or coefficient) “A” is the intercept term. The presence of a positive value for the “A” intercept means that there is a cost of doing business, regardless of the number of customers. The coefficient “B” represents the incremental cost of one additional customer. The coefficient “C” represents the incremental cost associated with one incremental unit of customer density. Equation 3 Equation 3 is a simplification. However, it illustrates one of the advantages of econometric analysis, in the sense that the impact of individual factors (i.e., the number of customers or customer density) on distribution service costs can be simultaneously yet independently analyzed. The coefficients A, B, and C are estimated by collecting real-world data on distribution service costs, the number of customers served, and the customer density, and utilizing one of many possible regression estimation techniques. Sample Operating Area Data Figure 34: Operating Area 2010 Customer Density (per square kilometre) Density (customers per km2 ) 40 2010 35 30 25 20 15 10 - Newmarket Dundas Bowmanville Essex Winchester Kingston Orangeville Penetangui… Fenelon Falls Brockville Orillia Picton Vankleek Hill Barrie Owen Sound Peterborough Lincoln Perth Aylmer Alliston Lambton Arnprior Tweed Beachville Listowel Clinton Strathroy Bracebridge Bancroft Kent Minden Walkerton Guelph Sudbury Simcoe Parry Sound Huntsville Cobden Manitoulin Algoma New Liskeard Nipissing Kirkland… Timmins Kenora Kapuskasing Thunder Bay Dryden 5 Source: HONI; LEI and PNXA analysis London Economics International LLC Benjamin Grunfeld/Steven Kim [phone removed] [email removed] 49 PowerNex Associates Inc. Mark Vainberg/Gary Ford/Andrew Poray [phone removed] [email removed]Page 71 of 99
Tweed Peterborough Perth Owen Sound Winchester Thunder Bay Cobden Newmarket Kingston Bancroft Barrie Fenelon Falls Huntsville Essex Bracebridge Sudbury Beachville Orangeville Brockville Nipissing Parry Sound Dundas Vankleek Hill Minden Walkerton Kenora Arnprior Kent Picton Clinton Penetanguishene Bowmanville Simcoe Orillia Strathroy Timmins Dryden Lambton Guelph Aylmer Lincoln New Liskeard Kapuskasing Alliston Manitoulin Algoma Listowel Kirkland Lake Dundas Newmarket Lincoln Bowmanville Timmins Vankleek Hill Kingston Winchester Brockville Orillia Arnprior Sudbury Picton Essex Fenelon Falls Penetanguis… Barrie Owen Sound Tweed Algoma Bracebridge Peterborough Perth Kirkland Lake Minden Simcoe Orangeville Cobden Nipissing Guelph Lambton Alliston Huntsville Bancroft Listowel Kapuskasing Aylmer Parry Sound Clinton Thunder Bay Walkerton New Liskeard Beachville Manitoulin Strathroy Kent Kenora Dryden Customer Density and Distribution Service Costs Figure 35: Operating Area 2010 Customer Density (per circuit kilometre) Density (customers per line-km) 30 London Economics International LLC Benjamin Grunfeld/Steven Kim [phone removed] [email removed] 2010 25 20 15 10 5 Source: HONI; LEI and PNXA analysis Figure 36: Operating Area 2010 OM&A Cost Total Operating Area OM&A Cost (millions $) 10 50 2010 9 8 7 6 5 4 3 2 1 - Source: HONI; LEI and PNXA analysis PowerNex Associates Inc. Mark Vainberg/Gary Ford/Andrew Poray [phone removed] [email removed]Page 72 of 99
Winchester Tweed Peterborough Newmarket Barrie Perth Owen Sound Kingston Fenelon Falls Orangeville Essex Thunder Bay Cobden Bancroft Huntsville Vankleek Hill Bracebridge Sudbury Walkerton Kenora Timmins Parry Sound Minden Nipissing Brockville Bowmanville Dundas Arnprior Guelph Beachville Alliston Strathroy Simcoe Kent Clinton Picton Dryden Penetanguishene Lambton Orillia Manitoulin Lincoln Aylmer New Liskeard Algoma Kirkland Lake Kapuskasing Listowel Customer Density and Distribution Service Costs Figure 37: Operating Area 2010 Capital Proxy Total Operating Area Capital Cost (millions $) 18 London Economics International LLC Benjamin Grunfeld/Steven Kim [phone removed] [email removed] 2010 16 14 12 10 8 6 4 2 - Source: HONI; LEI and PNXA analysis 51 PowerNex Associates Inc. Mark Vainberg/Gary Ford/Andrew Poray [phone removed] [email removed]Page 73 of 99
Customer Density and Distribution Service Costs Appendix B – Background Information on Distribution Systems Distribution System Topology and Equipment Electricity is typically generated at relatively low voltages, in the range of 20 to 25 kilovolts (“kV”) in major generating stations and immediately transformed up to higher voltages (115 kV, 230 kV and 500 kV) for transmission to load centres. Figure 38: Simplified Generation/Transmission/Distribution Model Source: PNXA Transmission substations transform the voltage back down to typically 44 kV for bulk distribution of power via what are called sub-transmission or “M Class” feeders that supply distribution stations. Distribution stations further transform the voltage down to typically 8 kV for distribution feeder circuits that are used to supply customers. A simplified generation, transmission, and distribution system model is illustrated in Figure 38. The transformation process then continues one further step down to the 600, 230 or 115 volt (“V”) level used in customers’ homes and businesses. This last transformation is done by poletop or pad-mounted transformers located relatively close to the customers, as illustrated in Figure 39. London Economics International LLC Benjamin Grunfeld/Steven Kim [phone removed] [email removed] 52 PowerNex Associates Inc. Mark Vainberg/Gary Ford/Andrew Poray [phone removed] [email removed]Page 74 of 99
Customer Density and Distribution Service Costs Figure 39: Typical Single Phase Pole-Top Transformer Source: PNXA files The primary elements that make up a distribution system are the distribution feeders (lines or cables), distribution stations, and metering and control systems. However, each of these elements is comprised of many types of components. Overhead distribution lines, as illustrated in Figure 39, include aluminum primary conductors, porcelain or polymeric line insulators, fuses and fuse holders, pole-top transformers, secondary wiring, poles and pole hardware. Underground and submarine cables are used sparingly because they are significantly more costly than overhead lines. They include insulated primary cable, and pre-moulded terminations and splices. Distribution stations vary in design and complexity depending on their location and the number of feeders connected by them. Figure 40 illustrates a typical open air distribution station. London Economics International LLC Benjamin Grunfeld/Steven Kim [phone removed] [email removed] 53 PowerNex Associates Inc. Mark Vainberg/Gary Ford/Andrew Poray [phone removed] [email removed]Page 75 of 99
Customer Density and Distribution Service Costs Figure 40: Typical Open Air Distribution Station Source: PNXA files Stations of this type include transformers, circuit breakers and/or re-closers, disconnect switches, grounding switches, bus conductors, protection, control and metering equipment, station cables to facilitate line entrances and exits, and structural elements. In built-up areas distribution stations may be enclosed in buildings or surrounded by improved appearance walls and other aesthetic treatments. Power quality standards require that the voltage and frequency be maintained within prescribed limits. The frequency is controlled at the bulk transmission system level, however, voltage control is a concern on distribution systems. Current flowing on long distribution feeders causes a voltage drop along the feeder that is a function of loading. As well, loads with lagging power factors (inductive loads for example, motors, air conditioners, etc.) require reactive compensation in the form of capacitor banks which need to be switched in or out as required. Voltage regulators, such as the single phase unit illustrated in Figure 41, are in common use on long feeders to provide controlled voltage support when loads are high and series inductors to limit voltage levels when loads are low. London Economics International LLC Benjamin Grunfeld/Steven Kim [phone removed] [email removed] 54 PowerNex Associates Inc. Mark Vainberg/Gary Ford/Andrew Poray [phone removed] [email removed]Page 76 of 99
Customer Density and Distribution Service Costs Figure 41: Single Phase Voltage Regulator (Left) and Three Phase Series Inductor (Right) Source: PNXA files Operation and Maintenance of Distribution Systems Distribution infrastructure requires continual monitoring to ensure that the system is operating normally and within the prescribed operational limits. Loadings need to be monitored to ensure that currents and voltages are within equipment ratings, that loadings on the three phases of feeders are balanced, and that opportunities for lowering system losses and improving operational efficiencies are acted upon. The condition of distribution station transformers needs to be monitored, circuit breakers and re-closers include moving parts which wear out and need to be replaced, wood poles rot and are attacked by insects and birds, and vegetation impinges on lines and needs to be removed or trimmed for safety and reliability concerns. In addition, failures and weather related outages occur, which require immediate action to repair because many cause customers to be without power for a period of time. The extent of operational maintenance and repair is influenced by the age of the infrastructure, the environment in the location in the province, and the geography of the location (e.g., heavily forested versus farm land). This latter factor also influences the topology of the system which affects work methods and accessibility. The topology of distribution systems can vary considerably which may impact distribution operating and sustainment costs. Figure 42 is a snapshot view from HONI’s GIS showing one of the distribution stations in the Bracebridge operating area and a number of feeders supplied from that distribution station, as well as the location of the transformers supplying customers on the feeders. London Economics International LLC Benjamin Grunfeld/Steven Kim [phone removed] [email removed] 55 PowerNex Associates Inc. Mark Vainberg/Gary Ford/Andrew Poray [phone removed] [email removed]
Text of CIEC-20 (d) Attachment 1 - PG&E Rate B-20.pdf
Extracted from the file · 24 pages · 63,774 characters
Text of CIEC-20 (d) Attachment 2 - PSCo Schedule PG.pdf
Extracted from the file · 3 pages · 7,608 characters
As listed on the current system
Question(s) Answered 2 thru 20 (OCC) Date Filed: 11/12/2026