Interrogatory responses
Answers to questions 2 thru 20
Files10
OCC Response to CIEC Second Set of Requests.pdf
PDF · 571 KB · 25 pagesText searchable
Download OCC Response to CIEC Second Set of Requests.pdfRead the text of OCC Response to CIEC Second Set of Requests.pdf
Response to CIEC-2 (a) Classification of AMI-related costs.xlsx
Excel · 16 KBText searchable
Download Response to CIEC-2 (a) Classification of AMI-related costs.xlsxRead the text of Response to CIEC-2 (a) Classification of AMI-related costs.xlsx
Response to CIEC-8 (b) Allocation of AMI meter costs.xlsx
Excel · 16 KBText searchable
Download Response to CIEC-8 (b) Allocation of AMI meter costs.xlsxRead the text of Response to CIEC-8 (b) Allocation of AMI meter costs.xlsx
CIEC-9 (d) Attachment A C17-0556_16A-0588E.pdf
PDF · 177 KB · 16 pagesText searchable
Download CIEC-9 (d) Attachment A C17-0556_16A-0588E.pdfRead the text of CIEC-9 (d) Attachment A C17-0556_16A-0588E.pdf
CIEC-9 (d) Attachment B 2023-CO-Phase-II-Electric-Rate-Review-Decision.pdf
PDF · 476 KB · 45 pagesText searchable
Download CIEC-9 (d) Attachment B 2023-CO-Phase-II-Electric-Rate-Review-Decision.pdfRead the text of CIEC-9 (d) Attachment B 2023-CO-Phase-II-Electric-Rate-Review-Decision.pdf
CIEC-12 Attachment - Bonbright Excerpt.pdf
PDF · 136 KB · 4 pagesText read by machine from a scan; may contain errors, especially in numbers
Download CIEC-12 Attachment - Bonbright Excerpt.pdfScanned pages and text of CIEC-12 Attachment - Bonbright Excerpt.pdf
CIEC-13 (a) Attachment - rate_order_Hydro One DX 2013_20121220.pdf
PDF · 245 KB · 31 pagesText searchable
Download CIEC-13 (a) Attachment - rate_order_Hydro One DX 2013_20121220.pdfRead the text of CIEC-13 (a) Attachment - rate_order_Hydro One DX 2013_20121220.pdf
CIEC-13 (d) - Hydro One Density Study HONI_APPL_Exhibit D_20120615.pdf
PDF · 3.3 MB · 99 pagesText searchable
Download CIEC-13 (d) - Hydro One Density Study HONI_APPL_Exhibit D_20120615.pdfRead the text of CIEC-13 (d) - Hydro One Density Study HONI_APPL_Exhibit D_20120615.pdf
CIEC-20 (d) Attachment 1 - PG&E Rate B-20.pdf
PDF · 1.9 MB · 24 pagesText searchable
Download CIEC-20 (d) Attachment 1 - PG&E Rate B-20.pdfRead the text of CIEC-20 (d) Attachment 1 - PG&E Rate B-20.pdf
CIEC-20 (d) Attachment 2 - PSCo Schedule PG.pdf
PDF · 198 KB · 3 pagesText searchable
Download CIEC-20 (d) Attachment 2 - PSCo Schedule PG.pdfRead the text of CIEC-20 (d) Attachment 2 - PSCo Schedule PG.pdf
Text of CIEC-9 (d) Attachment A C17-0556_16A-0588E.pdf
Extracted from the file · 16 pages · 28,745 characters
Text of CIEC-9 (d) Attachment B 2023-CO-Phase-II-Electric-Rate-Review-Decision.pdf
Extracted from the file · 45 pages · 89,290 characters
Scanned pages of CIEC-12 Attachment - Bonbright Excerpt.pdf
Read by machine from a scan · 4 pages · may contain errors, especially in numbers
Text of CIEC-13 (a) Attachment - rate_order_Hydro One DX 2013_20121220.pdf
Extracted from the file · 31 pages · 41,898 characters
Text of CIEC-13 (d) - Hydro One Density Study HONI_APPL_Exhibit D_20120615.pdf
Extracted from the file · 99 pages · 204,526 characters
Text of CIEC-20 (d) Attachment 1 - PG&E Rate B-20.pdf
Extracted from the file · 24 pages · 63,774 characters
Page 1
COLO. PUC No. 8 Electric PUBLIC SERVICE COMPANY OF COLORADO P.O. Box 840 Denver, CO 80201-0840 Seventh Revised Sheet No. 55 Sixth Revised Cancels Sheet No. 55 RATE ELECTRIC RATES PRIMARY GENERAL SERVICE SCHEDULE PG APPLICABILITY Applicable to electric power service supplied at Primary Voltage to Commercial and Industrial Customers. Applicable to Supplemental Service. Not applicable to Standby or Resale Service. AVAILABILITY As set forth in the General Definition Section of the Electric Tariff, Customers taking Service under this Schedule and under Schedule Net Metering (Schedule NM), will not be subject to the requirements of Supplemental Service. MONTHLY RATE Service and Facility Charge, per service meter: ..................................................... $ 894.00 Production Meter Charge .................................................................................. 368.00 Load Meter Charge ............................................................................................ 368.00 Demand Charge: All Kilowatts of Billing Demand, per kW Distribution Demand ...................................................................... Generation and Transmission Demand – Summer Season ........... Generation and Transmission Demand – Winter Season .............. 5.61 17.03 11.42 Energy Charge: All Kilowatt-Hours used, per kWh ............................................................. 0.00701 The Summer Season shall be from June 1 through September 30. The Winter Season shall be from October 1 through May 31. MONTHLY MINIMUM The Service and Facility Charge plus the Demand Charge, plus the Production Meter Charge if applicable. For Customers receiving Supplemental Service, the Monthly minimum shall also include the Production Meter Charge. OPTIONAL SERVICE Except for Customers receiving Supplemental Service, Customers receiving service under this rate may elect to receive interruptible service under the Interruptible Service Option Credit (ISOC). ADJUSTMENTS This rate schedule is subject to all applicable Electric Rate Adjustments as on file and in effect in this Electric Tariff. (Continued on Sheet No. 55A) ADVICE LETTER NUMBER 1996 DECISION/ PROCEEDING NUMBER C25-0415/C25-0668 REGIONAL VICE PRESIDENT, Rates & Regulatory Affairs ISSUE DATE October 22, 2025 EFFECTIVE DATE November 1, 2025 I IPage 2
COLO. PUC No. 8 Electric PUBLIC SERVICE COMPANY OF COLORADO P.O. Box 840 Denver, CO 80201-0840 Second Revised Sheet No. 55A First Revised Cancels Sheet No. 55A RATE ELECTRIC RATES PRIMARY GENERAL SERVICE SCHEDULE PG PAYMENT AND LATE PAYMENT CHARGE Bills for electric service are due and payable within fourteen (14) business days from date of bill. A business day for purposes under this Payment and Late Payment Charge section is all non-Holiday weekdays. Any amounts in excess of fifty dollars ($50.00) not paid on or before three (3) business days after the due date of the bill shall be subject to a late payment charge of one and one half percent (1.5%) per Month. DETERMINATION OF BILLING DEMAND Billing Demand, determined by meter measurement, shall be the maximum fifteen (15) minute integrated Measured Demand used during the Month, except as otherwise set forth in the Commercial and Industrial Rules and Regulations. Summer Season Billing Demand for the Generation and Transmission Demand Charge, shall be the Measured Demand used between 4:00 p.m. and 9:00 p.m. Mountain Time on all non-Holiday weekdays. Winter Season Billing Demand for the Generation and Transmission Demand Charge, shall be the Measured Demand used between 5:00 p.m. and 9:00 p.m. Mountain Time on all non-Holiday weekdays. Billing Demand for the Distribution Demand Charge shall be the greater of: Measured Demand used during the Month, or fifty percent (50%) of the highest Measured Demand occurring during the preceding twelve (12) Months. For Supplemental Service, Summer Season Billing Demand for the Generation and Transmission Demand Charge shall be the Measured Demand used between 4:00 p.m. and 9:00 p.m. Mountain Time on all non-Holiday weekdays net of the Customer’s generation. For Supplemental Service, Winter Season Billing Demand for the Generation and Transmission Demand Charge shall be the Measured Demand used between 5:00 p.m. and 9:00 p.m. Mountain Time on all non-Holiday weekdays net of the Customer’s generation. For Supplemental Service, Billing Demand for the Distribution Demand Charge shall be the greater of: Measured Demand net of the Customer’s generation or fifty percent (50%) of the highest Measured Demand net of the Customer’s generation occurring during the preceding twelve (12) Months. (Continued on Sheet No. 55B) ADVICE LETTER NUMBER 1996 DECISION/ PROCEEDING NUMBER C25-0415/C25-0668 REGIONAL VICE PRESIDENT, Rates & Regulatory Affairs ISSUE DATE October 22, 2025 EFFECTIVE DATE November 1, 2025 ND ND ND N N N ND ND ND ND N N N NPage 3
COLO. PUC No. 8 Electric PUBLIC SERVICE COMPANY OF COLORADO P.O. Box 840 Denver, CO 80201-0840 First Revised Sheet No. 55B Original Cancels Sheet No. 55B RATE ELECTRIC RATES PRIMARY GENERAL SERVICE SCHEDULE PG SERVICE PERIOD All service under this schedule shall be for a minimum period of twelve (12) consecutive Months and Monthly thereafter until terminated. If service is no longer required by Customer, service may be terminated on thirty (30) days' notice. Greater minimum periods may be required by contract in situations involving large or unusual loads. PRODUCTION METER INSTALLATION The Company shall install, own, operate and maintain the metering to measure the electric power and energy supplied by the Customer’s generation. For Supplemental Service, the Customer shall pay the Monthly Production Meter Charge under this schedule. For Customers who are net metered, the applicability of the Production Meter Charge can be found under the Net Metering Service Schedule. LOAD METER INSTALLATION The Company shall install, own, operate and maintain the metering to measure the electric power and energy supplied by the Customer’s generation under this schedule and determine the full load obligations of the Customer. For Supplemental Service, the Customer shall pay the Monthly Load Meter Charge under this schedule. For Customers who are net metered, the applicability of the Load Meter Charge can be found under the Photovoltaic Service Schedule. PURCHASE OF CUSTOMER’S EXCESS ENERGY If a Customer receiving Supplemental Service produces energy exceeding the energy used by the Customer’s facility during any Monthly billing period, the energy shall be purchased by the Company either under a Power Purchase Agreement between the Company and the Customer, or at the Energy Charge under this schedule. RULES AND REGULATIONS Service supplied under this schedule is subject to the terms and conditions set forth in the Company's Rules and Regulations on file with the Commission and the following conditions: 1. For those Customers receiving Primary Voltage and who desire to elect Secondary Voltage, they may do so subject to the terms and conditions of Primary/Secondary Conversions. 2. Customers with generation resources connected in parallel with the Company’s electric system are subject to the Character of Service for Secondary, Primary and Transmission Standby Service section of the Company’s Rules and Regulations for Commercial and Industrial Service. ADVICE LETTER NUMBER DECISION/ PROCEEDING NUMBER 1736 REGIONAL VICE PRESIDENT, Rates & Regulatory Affairs ISSUE DATE February 21, 2017 EFFECTIVE DATE March 24, 2017 C N N N N N N N
As listed on the current system
Question(s) Answered 2 thru 20 (OCC) Date Filed: 11/12/2026