The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 23 Page 11 of 147 2. Contractors reported that they could readily obtain heat pump equipment and were not dealing with supply chain issues at the time of the focus groups. 3. Contractors leverage utility rebates, tax credits, and local government rebates to reduce upfront heat pump installation expenses. These contractors noted that incentives play a very important role in making heat pumps an attractive option for many households. 4. Contractors noted a lack of incentives for meHPs that could be considered the most direct replacement for a CAC. Contractors reported that some customers still prefer to replace failed CACs with new CACs to minimize upfront cost. 5. For CAC-replacement scenarios, contractors reported minimal differences between installations of heat pumps and CACs, with the main difference being the need for additional wiring for heat pump controls. 6. Contractors reported that many Colorado households currently have low awareness of heat pumps and do not know the benefits of heat pump technology. The contractors noted that they usually introduce customers to heat pumps by talking about heat pump rebate programs and say customers are often receptive to the sales pitch. Strategic Considerations Based on the findings in this white paper, the team has identified the following areas as important strategic considerations for the effective implementation of a Residential CAC Standard in Colorado. Identify opportunities to create incentives for meHPs The most affordable heat pumps (meHPs) are not currently eligible for rebates or tax credits at the state or federal level and determining which heat pump equipment is eligible for rebates is time consuming and confusing for both homeowners and HVAC contractors. Providing a $2,000 incentive to each household that installs a heat pump would ensure that almost all households in Colorado benefit economically from thePage 12 of 147
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 23 Page 12 of 147 heat pump and making meHPs eligible for incentives would reduce prices for consumers and make it easier for homeowners and HVAC contractors to utilize incentive programs. Set an effective date for the standard that allows the market to prepare The HVAC contractors that were interviewed during this research effort primarily installed high performance heat pumps or ccHPs. Colorado utility rebate program usage data and market share data from Heating Air-Conditioning Refrigeration Distributors International (HARDI) support that most of the existing heat pump customer base in Colorado are choosing to install heat pumps with high or moderately high performance (i.e. not meHPs). If a Residential CAC Standard goes into effect, the residential heat pump market would likely expand significantly beyond this current customer base. Data from HARDI shows that approximately 70% of residential CACs sold in Colorado are low efficiency units, so most equipment that would be affected by the Residential CAC Standard would be low cost meCACs. To reduce upfront costs, households may prefer to install meHPs after CAC failures. An ample planning period would allow Colorado distributors to ensure meHPs and other low-cost heat pump options are in stock prior to any Residential CAC Standard implementation. EPCA preemption may pose legal hurdles for a Residential CAC Standard Multiple stakeholders indicated that a Residential CAC Standard is likely to receive legal challenges based on existing federal air conditioner efficiency standards. Such legal challenges could potentially prevent implementation of the standard or could delay implementation and create market confusion during protracted legal proceedings. Developing a legal strategy to prevent EPCA challenges could be important in case the state sees a legal challenge related to a Residential CAC Standard.Page 13 of 147
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 23 Page 13 of 147 Examine utility electric rate structures that are beneficial for households with heat pumps Utilities could improve heat pump economics for households by offering electric rate structures that reduce the cost of operating heat pumps for space heating in the winter. Such rate structures have been shown to improve heat pump economics in other regions of the United States. SB24-214, passed by Colorado General Assembly in 2024, requires that investor-owned utilities in Colorado develop proposals for electric rate structures that are designed to lower the average monthly energy bill for residential households that utilize heat pumps as their primary heating source. Examining the advantages and disadvantages of these rate structures will be important if heat pump adoption accelerates in the coming years. Structure the Residential CAC Standard to apply to all residential CACs The Residential CAC Standard examined in this analysis would only apply to CACs utilized in one and two family dwelling units and townhouses. Thus, it would still be legal to sell CACs for use in residential building types that are not covered by the standard, potentially creating confusion for HVAC equipment distributors and retailers. It may be more effective to design a Residential CAC Standard to apply to all residential CACs below a nominal cooling output threshold. For example, the standard could apply to all CACs with rated capacity below 65,000 Btu per hour, regardless of the building type or size that the CAC will be installed in. Develop low-cost financing options for households that install heat pumps The incremental cost estimated for a meHP installation is $2,200, which can be a significant added financial burden for many households after they experience a CAC failure. Low-cost financing options would reduce this burden and would allow households to better manage the financial impacts of a Residential CAC Standard.Page 14 of 147
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 23 Page 14 of 147 Introduction Colorado has established statewide emission targets to reduce greenhouse gas (GHG) emissions based on the levels that existed in 2005, including a 50% reduction by 2030, a 65% reduction by 2035, and net zero emissions by 2050. In 2021, the Colorado Greenhouse Gas Pollution Reduction Roadmap 3 identified that electrification and decarbonization of space heating in residential buildings will be important for Colorado to meet its 2050 climate goal. Increased adoption of electric heat pump technology is likely to be a key contributor to the residential building electrification effort because heat pumps operate at much higher efficiency than electric resistance heating technologies. In Colorado, a variety of strategies are currently being used to accelerate the adoption of heat pump technology for space heating in the residential building sector. Examples include the Colorado State Heat Pump Tax Credit, heat pump rebates from utility programs, heat pump rebates from local governments, and federal tax credits and Inflation Reduction Act rebates. These incentive-based strategies encourage homeowners and heating, ventilation, and air conditioning (HVAC) contractors to install heat pumps by reducing the upfront cost for heat pump installations. This white paper examines the potential effects of a statewide point-of-sale standard that would require new residential central air conditioners (CACs) serving one and two family dwelling units and townhouses to be configured as heat pumps (this point-ofsale standard will hereafter be referred to as the “Residential CAC Standard”). Such a standard would effectively mandate that heat pumps be installed instead of new CACs in the applicable residential building types. The potential impacts if a Residential CAC Standard was implemented in Colorado have not been investigated to date. To analyze the impacts of a Residential CAC Standard in Colorado, the Colorado Energy Office (CEO) and Apex Analytics (jointly referred to as “the team”) conducted 3 Colorado Greenhouse Gas Pollution Reduction Roadmap, 2021Page 15 of 147
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 23 Page 15 of 147 research interviews with stakeholders including HVAC equipment manufacturers and distributors, HVAC contractors, heat pump experts, green homebuilders, environmental justice groups, and utilities. Using the data collected through this primary research, the team conducted engineering and economic analyses to assess upfront heat pump installation costs and operational costs under a variety of scenarios. The primary objective of this analysis was to assess factors that are likely to affect the impacts of a Residential CAC Standard. These factors include, assessing heat pump technical viability, examining heat pump installation and operating costs, evaluating HVAC workforce readiness, and estimating the statewide economic and greenhouse gas (GHG) emission impacts of a Residential CAC Standard.Page 16 of 147
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 23 Page 16 of 147 Analysis Methodology This analysis was performed to determine how a Residential CAC Standard would impact the following: • Household and statewide energy consumption, including changes in natural gas, propane, and electricity usage • Household and statewide GHG emissions from space heating and cooling • Household-level utility bills and total heating and cooling costs, and the associated statewide costs when aggregated across all impacted households The team also examined the following factors specific to CAC-to-heat pump replacements: • The presumed payback period (if any) based on annual utility bill savings and the incremental cost of a heat pump installation vs. a CAC installation • The influence of natural gas or propane and electricity prices on heat pump economics and GHG emission reduction potential • The influence of climate zones and geographically defined analysis regions on heat pump economics and GHG emission reduction potential • How heat pump economics and GHG emission reduction potential depend on heat pump equipment efficiency Estimating the Reach of a Residential CAC Standard To start the analysis, the team utilized the NREL Restock Database 4 and subdivided the Colorado data to estimate the number of households that would be impacted by the Residential CAC Standard. The population impacted by the standard includes residential one and two family dwelling units and townhouses with CAC installed or future new construction projects that are expected to install CAC. Out of the existing 4 NREL ResStock DatasetPage 17 of 147
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 23 Page 17 of 147 2,377,943 households in Colorado, 1,147,720 households are expected to be impacted by the standard. The team subdivided Colorado into 16 Geographic Analysis Regions, which were selected to capture variability in climate, housing, energy consumption patterns, fuel prices and electricity prices. When placing counties in the respective Geographic Analysis Regions, all counties in climate zone 4B were grouped in one region named Southeast Colorado and all counties in climate zones 6B and 7B were similarly grouped into the 6B Mountain and 7B High Mountain analysis regions, respectively. Climate zone 5B, where 91% of impacted households are located, was split into 13 more granular regions to better capture the variability of housing stock and electricity and fuel rates within this climate zone. Appendix Table 32 shows the estimated number of impacted households in each Colorado county and shows the relationship between county, climate zone, and the Geographic Analysis Regions. While the total potential population that could be impacted by the Residential CAC Standard is 1,147,720 households, only those households that are purchasing new CACs in any given year are impacted each year. The number of CAC installations in retrofit scenarios that happen each year is estimated by multiplying the total impacted population by the estimated yearly turnover rate of residential CAC equipment, 5%. 5 In addition to retrofit installations, residential new construction projects that will include space cooling equipment are also impacted by the standard. To estimate the number of new construction units that will be impacted each year, the team added the forecasted county level increase in housing units from the Colorado Department of Local Affairs (DOLA) 6 to the estimated demolition rate from the Hud User Office of Policy Development and Research 7 to produce an estimate of total new constructed housing units. The team then multiplied total new construction housing units by the percent of homes with CACs per county from the 2000-2020 vintage from the ResStock database to estimate the number of newly constructed 5 Updated Buildings Sector Appliance and Equipment Costs and Efficiencies, This source provides a lifetime range of 11 to 25 years; the team used professional judgment to select an average CAC lifetime of 20 years to estimate the number of annual CAC failures that lead to replacement. 6 7 Excel file download link: DOLA forecasted county level increase in housing units Estimated housing demolition rates from HUDPage 18 of 147
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 23 Page 18 of 147 homes with CAC installed each year. The team estimates 81,696 households and 81,696 CAC installation projects will be impacted by the Residential CAC Standard each year. 8 Assuming full compliance with the standard, these impacted CAC projects would result in the installation of 81,696 heat pumps each year. Table 3 shows the estimated number of households and CAC installation projects impacted by the Residential CAC Standard in each Geographic Analysis Region, broken down by project type. Table 4 breaks down the estimated number of annual CAC installation projects by household existing primary heating fuel based on data from ResStock. Overall, 85%, 5.6%, and 9.4% of impacted CAC installations will occur in households with natural gas furnaces, propane furnaces, and electric resistance heating systems, respectively. Table 3. Estimated number of CAC installations impacted by the Residential CAC Standard, by project type Annual Annual Retrofit New Construction CAC Installations CAC Installations Southeastern Colorado 429 23 452 6B Mountain 2,018 703 2,721 7B High Mountain 2,561 848 3,409 Adams County 4,630 2,459 7,088 Arapahoe County 5,816 2,301 8,117 Boulder_Broomfield_Gilpin 4,176 1,729 5,905 Denver County 4,806 2,216 7,022 Geographic Analysis Region 8 Assuming one CAC unit is installed in each impacted household Total Annual CAC InstallationsPage 19 of 147
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 23 Page 19 of 147 Annual Annual Retrofit New Construction CAC Installations CAC Installations Douglas_Elbert 4,453 1,940 6,393 El Paso_Fremont_Teller 8,553 3,662 12,215 Jefferson County 5,879 1,663 7,542 La Plata_Montezuma 870 356 1,227 Larimer County 3,797 1,758 5,556 Mesa Area 3,179 1,775 4,954 Morgan Area 770 124 893 Pueblo Area 2,523 768 3,291 Weld County 2,914 1,986 4,900 Total: 57,373 24,310 81,684 Geographic Analysis Region Total Annual CAC Installations Table 4. Estimated number of impacted CAC installations broken down by existing household heating system type Annual CAC Annual CAC Annual CAC Geographic Analysis Installations, Installations, Installations, Region Natural Gas Propane Electric Resistance Furnace Furnace Heating Systems Southeastern Colorado 319 106 27 6B Mountain 1,905 561 255 7B High Mountain 2,468 521 420Page 20 of 147
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 23 Page 20 of 147 Annual CAC Annual CAC Annual CAC Geographic Analysis Installations, Installations, Installations, Region Natural Gas Propane Electric Resistance Furnace Furnace Heating Systems Adams County 6,258 58 773 Arapahoe County 7,025 123 968 Boulder_Broomfield_Gilpin 5,352 250 303 Denver County 6,359 18 645 Douglas_Elbert 5,415 380 598 El Paso_Fremont_Teller 10,233 667 1,315 Jefferson County 6,700 81 761 La Plata_Montezuma 747 356 124 Larimer County 5,002 240 314 Mesa Area 4,148 472 334 Morgan Area 527 234 132 Pueblo Area 2,764 280 247 Weld County 4,285 191 424 Total: 69,507 4,538 7,639
As listed on the current system
Question(s) Answered 11 (Connecticut Light and Power Company dba Eversource Energy) Date Filed: 08/27/2026