Skip to main content

A prototype public docket site for the Connecticut Public Utilities Regulatory Authority

Utility Dockets and Filings

Interrogatory responses

Answers to questions 11

ResponseFiled by Connecticut Light and Power Company dba Eversource Energy2 files
Part of docket 26-05-10Open
  • Electric
Application of The Connecticut Light and Power Company d/b/a Eversource Energy to Amend its Rate Schedules

Files2

  1. Page 18 of 147

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 23 Page 18 of 147 homes with CAC installed each year. The team estimates 81,696 households and 81,696 CAC installation projects will be impacted by the Residential CAC Standard each year. 8 Assuming full compliance with the standard, these impacted CAC projects would result in the installation of 81,696 heat pumps each year. Table 3 shows the estimated number of households and CAC installation projects impacted by the Residential CAC Standard in each Geographic Analysis Region, broken down by project type. Table 4 breaks down the estimated number of annual CAC installation projects by household existing primary heating fuel based on data from ResStock. Overall, 85%, 5.6%, and 9.4% of impacted CAC installations will occur in households with natural gas furnaces, propane furnaces, and electric resistance heating systems, respectively. Table 3. Estimated number of CAC installations impacted by the Residential CAC Standard, by project type Annual Annual Retrofit New Construction CAC Installations CAC Installations Southeastern Colorado 429 23 452 6B Mountain 2,018 703 2,721 7B High Mountain 2,561 848 3,409 Adams County 4,630 2,459 7,088 Arapahoe County 5,816 2,301 8,117 Boulder_Broomfield_Gilpin 4,176 1,729 5,905 Denver County 4,806 2,216 7,022 Geographic Analysis Region 8 Assuming one CAC unit is installed in each impacted household Total Annual CAC Installations
  2. Page 19 of 147

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 23 Page 19 of 147 Annual Annual Retrofit New Construction CAC Installations CAC Installations Douglas_Elbert 4,453 1,940 6,393 El Paso_Fremont_Teller 8,553 3,662 12,215 Jefferson County 5,879 1,663 7,542 La Plata_Montezuma 870 356 1,227 Larimer County 3,797 1,758 5,556 Mesa Area 3,179 1,775 4,954 Morgan Area 770 124 893 Pueblo Area 2,523 768 3,291 Weld County 2,914 1,986 4,900 Total: 57,373 24,310 81,684 Geographic Analysis Region Total Annual CAC Installations Table 4. Estimated number of impacted CAC installations broken down by existing household heating system type Annual CAC Annual CAC Annual CAC Geographic Analysis Installations, Installations, Installations, Region Natural Gas Propane Electric Resistance Furnace Furnace Heating Systems Southeastern Colorado 319 106 27 6B Mountain 1,905 561 255 7B High Mountain 2,468 521 420
  3. Page 20 of 147

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 23 Page 20 of 147 Annual CAC Annual CAC Annual CAC Geographic Analysis Installations, Installations, Installations, Region Natural Gas Propane Electric Resistance Furnace Furnace Heating Systems Adams County 6,258 58 773 Arapahoe County 7,025 123 968 Boulder_Broomfield_Gilpin 5,352 250 303 Denver County 6,359 18 645 Douglas_Elbert 5,415 380 598 El Paso_Fremont_Teller 10,233 667 1,315 Jefferson County 6,700 81 761 La Plata_Montezuma 747 356 124 Larimer County 5,002 240 314 Mesa Area 4,148 472 334 Morgan Area 527 234 132 Pueblo Area 2,764 280 247 Weld County 4,285 191 424 Total: 69,507 4,538 7,639
  4. Page 21 of 147

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 23 Page 21 of 147 Estimating Heat Pump Cost, Energy, and Carbon Impacts Determining electric and fossil fuel prices After designating the Geographic Analysis Regions, a representative electric and gas utility was chosen for each region by identifying the utility that serves the most households in each region. The team then gathered the electric and gas rates for each utility (retrieved between December 2024 and January 2025). When multiple electric rates were available to households, the team analyzed the two most common rate options and utilized results from the rate structure that provided the lowest heating and cooling bills after heat pump installation. The rates were constructed into 8760 volumetric rates based on utility time of use (TOU) programs, as applicable. For natural gas rates, the team assumed a flat volumetric rate based on the latest available retail price data. For propane rates, the team used the statewide propane rate estimate assumed in the ResStock database. Table 5 shows each Geographic Analysis Region’s primary electric and gas utility, and Table 6 shows the volumetric rates for electricity, gas, and propane used for the economic analysis of each region. Due to the uncertainty in energy prices over 10+ year time spans, these rates were assumed to be constant over time when comparing the operational economics of heat pumps and CACs over time. Table 5. Geographic Analysis Region with the primary electric and gas utility Geographic Analysis Region Southeast Colorado 6B Mountain Primary Electric Utility Southeast Colorado Power Association Holy Cross Electric Association Primary Gas Utility Atmos Energy Black Hills Energy 7B High Mountain Xcel Energy Xcel Energy Adams County Xcel Energy Xcel Energy
  5. Page 22 of 147

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 23 Page 22 of 147 Geographic Analysis Region Primary Electric Utility Primary Gas Utility Arapahoe County Xcel Energy Xcel Energy Boulder_Broomfield_Gilpin Xcel Energy Xcel Energy Denver County Xcel Energy Xcel Energy Douglas_Elbert Core Electric Coop Black Hills Energy El Paso_Fremont_Teller City of Colorado Springs City of Colorado Springs Jefferson County Xcel Energy Xcel Energy La Plata_Montezuma La Plata Electric Assn, Inc Atmos Energy Larimer County City Of Fort Collins Xcel Energy Mesa Area Xcel Energy Xcel Energy Morgan Area Highline Electric Association Xcel Energy Pueblo Area Black Hills Utility Holdings Xcel Energy Weld County Xcel Energy Atmos Energy
  6. Page 23 of 147

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 23 Page 23 of 147 Table 6. Geographic Analysis Region primary electric and gas rates used for the economic analysis (rates gathered between December 2024 and January 2025) Geographic Analysis Region Electricity Electricity Natural Gas Propane Price #1 Price #2 Price Price ($/kWh) ($/kWh) ($/Therm) ($/Gallon) $0.71 $2.32 $1.34 $2.32 $0.13 first Southeast Colorado $0.13 1,000 kWh, $0.11 over 1,000 kWh Holy Cross 6B Mountain $0.11 Electric Association 9 9 7B High Mountain $0.13 Xcel TOU $0.87 $2.32 Adams County $0.13 Xcel TOU 10 $0.87 $2.32 Arapahoe County $0.13 Xcel TOU $0.87 $2.32 Boulder_Broomfield_Gilpin $0.13 Xcel TOU $0.87 $2.32 Denver County $0.13 Xcel TOU $0.87 $2.32 Douglas_Elbert $0.11 $0.70 $2.32 El Paso_Fremont_Teller $0.12 CO Springs $0.50 $2.32 Jefferson County $0.13 Xcel TOU $0.87 $2.32 La Plata_Montezuma $0.12 $0.62 $2.32 Core Electric Coop TOU 11 La Plata Electric Assn, Holy Cross Energy Electric Service Tariff, Rules and Regulations Xcel Energy Colorado TOU rate information 11 CORE Electric Cooperative Rates and Regulations 10
  7. Page 24 of 147

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 23 Page 24 of 147 Geographic Analysis Region Electricity Electricity Natural Gas Propane Price #1 Price #2 Price Price ($/kWh) ($/kWh) ($/Therm) ($/Gallon) Gas Heat TOU $0.87 $2.32 Xcel TOU $0.87 $2.32 $0.87 $2.32 Inc 12 Larimer County Mesa Area Electric Heat TOU 13 $0.13 Highline Morgan Area $0.09 Electric Association TOU 14 12 Pueblo Area $0.13 15 N/A $0.87 $2.32 Weld County $0.13 Xcel TOU $0.94 $2.32 LPEA electric rate information Fort Collins electric rate information 14 Highline Electric Association Tariff information 15 Shortly after the economic analysis for this white paper was performed, the electric rate for Black Hills customers was increased from $0.13/kWh to $0.16/kWh, PUC info on Black Hills rate case 13
  8. Page 25 of 147

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 23 Page 25 of 147 Heating system operation modeling The team aggregated 15 min interval data from ResStock into hourly heating and cooling loadshapes for each region. 16 These loadshapes include data on energy usage and GHG impacts. GHG impacts in ResStock are derived from the NREL Cambium dataset. 17 The electric grid emissions used are marginal emissions averaged over a 15year time horizon under cambium’s mid-case forecast scenario. The hourly emission values in this dataset are provided at the month-hour level, i.e., the forecasted emissions in each month are averaged for each hour of the day in that month. This methodology captures monthly and diurnal changes in electric grid GHG emissions but does not allow for a direct comparison between temperature and emission rates. 18 Emission intensity for natural gas and propane was sourced from ResStock and includes methane leakage from the natural gas system, expressed in CO2e. For all modeling, heat pumps were sized to cover cooling design loads typical of the Front Range region of Colorado (e.g. 2 to 3 tons cooling capacity). For households in climate zones 6B and 7, sizing for design cooling load according to standard sizing procedures (Manual J and Manual S) often results in the selection of very small heat pumps (smaller than is typically available for purchase). The number of households with CAC systems that are located in climate zones 6B and 7 is not very high, and the team assumes these homes are likely large in size, with above average cooling load requirements. Thus, the team assumed households with CACs in climate zones 6B and 7 would also utilize heat pumps sized to cover typical Front Range cooling loads. Note that sizing a heat pump to cover cooling load will typically result in a heat pump installation that is not capable of meeting the home’s full heating requirements. 16 ResStock includes a file for each model that contains 15 min interval data. The team assembled a database of each of these files, totaling 15-minute interval data for 4,549 models that represent the housing of all impacted residents. This data was summarized by region to create regional loadshapes that account for the housing stock and weather of each region. 17 NREL Cambium dataset 18 It is the authors opinion that this may result in a slight overestimate of emission benefits at lower switchover temperatures and a slight underestimate of emission benefits at higher switchover temperatures due to the expected relationship between the grid’s fraction of clean energy and ambient air temperature.
  9. Page 26 of 147

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 23 Page 26 of 147 Thus, we assume all households retain their existing heating systems and use them for backup or supplemental heat in dual fuel configurations (in homes with natural gas or propane furnaces) or all-electric heating systems (in homes with electric resistance heating systems). The regional 8760 energy and emission loadshapes were paired with a minimum efficiency heat pump (meHP) and cold-climate heat pump (ccHP) performance models 19 to estimate energy consumption, annual heating costs, and GHG emissions of the heat pumps when operated in dual fuel systems with differing switchover temperatures. The switchover temperature is the temperature at which the thermostat is programmed to switch from heating with the heat pump to heating with the natural gas or propane furnace in dual fuel heating systems. Heat pump performance and economics in households with existing electric resistance space heating systems were modeled without any heat pump switchover temperature and without setback-induced increases in electric resistance heating. As a result, in these all-electric heating systems, the heat pump was assumed to operate whenever it was capable of outputting heat (down to -5 degrees F for meHPs and -15 degrees F for ccHPs). The electric resistance heating system was modeled to supplement the heat pump when the heat pump heating output was lower than the building heat load. For meHPs, the range of switchover temperature examined was 20 to 50 degrees F. For ccHPs, switchover temperatures between 5 and 50 degrees F were examined. Below these minimum temperatures, a heat pump installed in a CAC-replacement scenario with no ductwork modifications or electrical infrastructure upgrades will likely have insufficient heating capacity to meet the building heating load. Thus, the team assumed the existing gas or propane furnace supplies all heating when the outdoor temperature is below the switchover temperature. At switchover 19 Equipment performance maps for modeled meHPs (Carrier 25SPA5) and ccHPs (Carrier 25VNA8) were used to develop an equipment performance model. Carrier publishes expanded product performance maps in a way that most other manufacturers do not.
  10. Page 27 of 147

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 23 Page 27 of 147 temperatures of 50 degrees F, the heat pump is only supplying a marginal amount of the annual heating load for the residential building. The team then determined the economically optimal switchover temperature for each heating system type in each Geographic Analysis Region, where the economically optimal switchover temperature is defined as the switchover temperature within the allowed range that provided the lowest annual heating utility bill. For the economic and GHG emission reduction impact analysis, the team assumed that households in each region would utilize the economically optimal switchover temperature when operating their heating system over the lifetime of the heat pump. The Residential CAC Standard analyzed does not require that households operate their heat pump heating systems with any particular switchover temperature and does not even explicitly require that the household utilize the heat pump for heating. The standard simply requires that a heat pump is installed instead of a CAC. That said, the team believes it is fair to assume that households will operate their heat pump system in an economically optimal manner that reduces heating utility bills. Figure 1 below shows the estimated annual heating cost for a dual fuel heating system composed of a meHP and 80% annual fuel utilization efficiency (AFUE) natural gas furnace for a range of switchover temperatures for various Geographic Analysis Regions. Regions with high natural gas costs (e.g. climate zone 6B-Mountains, Morgan County Area) have lower heating costs at lower switchover temperatures, while regions with low natural gas costs (e.g. El Paso County) have lower heating costs with higher switchover temperatures.

As listed on the current system

Question(s) Answered 11 (Connecticut Light and Power Company dba Eversource Energy) Date Filed: 08/27/2026

This filing on the current system (opens in a new tab)