Interrogatory responses
Answers to questions 11
Filed by Connecticut Light and Power Company dba Eversource Energy2 files
Part of docket 26-05-10Files2
CLF-011 Attachment 23.pdf
PDF · 16 MB · 147 pagesText searchable
Download CLF-011 Attachment 23.pdfRead the text of CLF-011 Attachment 23.pdf
CLF-011 Attachment 24.pdf
PDF · 1.8 MB · 6 pagesText searchable
Download CLF-011 Attachment 24.pdfRead the text of CLF-011 Attachment 24.pdf
Page 21 of 147
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 23 Page 21 of 147 Estimating Heat Pump Cost, Energy, and Carbon Impacts Determining electric and fossil fuel prices After designating the Geographic Analysis Regions, a representative electric and gas utility was chosen for each region by identifying the utility that serves the most households in each region. The team then gathered the electric and gas rates for each utility (retrieved between December 2024 and January 2025). When multiple electric rates were available to households, the team analyzed the two most common rate options and utilized results from the rate structure that provided the lowest heating and cooling bills after heat pump installation. The rates were constructed into 8760 volumetric rates based on utility time of use (TOU) programs, as applicable. For natural gas rates, the team assumed a flat volumetric rate based on the latest available retail price data. For propane rates, the team used the statewide propane rate estimate assumed in the ResStock database. Table 5 shows each Geographic Analysis Region’s primary electric and gas utility, and Table 6 shows the volumetric rates for electricity, gas, and propane used for the economic analysis of each region. Due to the uncertainty in energy prices over 10+ year time spans, these rates were assumed to be constant over time when comparing the operational economics of heat pumps and CACs over time. Table 5. Geographic Analysis Region with the primary electric and gas utility Geographic Analysis Region Southeast Colorado 6B Mountain Primary Electric Utility Southeast Colorado Power Association Holy Cross Electric Association Primary Gas Utility Atmos Energy Black Hills Energy 7B High Mountain Xcel Energy Xcel Energy Adams County Xcel Energy Xcel EnergyPage 22 of 147
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 23 Page 22 of 147 Geographic Analysis Region Primary Electric Utility Primary Gas Utility Arapahoe County Xcel Energy Xcel Energy Boulder_Broomfield_Gilpin Xcel Energy Xcel Energy Denver County Xcel Energy Xcel Energy Douglas_Elbert Core Electric Coop Black Hills Energy El Paso_Fremont_Teller City of Colorado Springs City of Colorado Springs Jefferson County Xcel Energy Xcel Energy La Plata_Montezuma La Plata Electric Assn, Inc Atmos Energy Larimer County City Of Fort Collins Xcel Energy Mesa Area Xcel Energy Xcel Energy Morgan Area Highline Electric Association Xcel Energy Pueblo Area Black Hills Utility Holdings Xcel Energy Weld County Xcel Energy Atmos EnergyPage 23 of 147
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 23 Page 23 of 147 Table 6. Geographic Analysis Region primary electric and gas rates used for the economic analysis (rates gathered between December 2024 and January 2025) Geographic Analysis Region Electricity Electricity Natural Gas Propane Price #1 Price #2 Price Price ($/kWh) ($/kWh) ($/Therm) ($/Gallon) $0.71 $2.32 $1.34 $2.32 $0.13 first Southeast Colorado $0.13 1,000 kWh, $0.11 over 1,000 kWh Holy Cross 6B Mountain $0.11 Electric Association 9 9 7B High Mountain $0.13 Xcel TOU $0.87 $2.32 Adams County $0.13 Xcel TOU 10 $0.87 $2.32 Arapahoe County $0.13 Xcel TOU $0.87 $2.32 Boulder_Broomfield_Gilpin $0.13 Xcel TOU $0.87 $2.32 Denver County $0.13 Xcel TOU $0.87 $2.32 Douglas_Elbert $0.11 $0.70 $2.32 El Paso_Fremont_Teller $0.12 CO Springs $0.50 $2.32 Jefferson County $0.13 Xcel TOU $0.87 $2.32 La Plata_Montezuma $0.12 $0.62 $2.32 Core Electric Coop TOU 11 La Plata Electric Assn, Holy Cross Energy Electric Service Tariff, Rules and Regulations Xcel Energy Colorado TOU rate information 11 CORE Electric Cooperative Rates and Regulations 10Page 24 of 147
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 23 Page 24 of 147 Geographic Analysis Region Electricity Electricity Natural Gas Propane Price #1 Price #2 Price Price ($/kWh) ($/kWh) ($/Therm) ($/Gallon) Gas Heat TOU $0.87 $2.32 Xcel TOU $0.87 $2.32 $0.87 $2.32 Inc 12 Larimer County Mesa Area Electric Heat TOU 13 $0.13 Highline Morgan Area $0.09 Electric Association TOU 14 12 Pueblo Area $0.13 15 N/A $0.87 $2.32 Weld County $0.13 Xcel TOU $0.94 $2.32 LPEA electric rate information Fort Collins electric rate information 14 Highline Electric Association Tariff information 15 Shortly after the economic analysis for this white paper was performed, the electric rate for Black Hills customers was increased from $0.13/kWh to $0.16/kWh, PUC info on Black Hills rate case 13Page 25 of 147
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 23 Page 25 of 147 Heating system operation modeling The team aggregated 15 min interval data from ResStock into hourly heating and cooling loadshapes for each region. 16 These loadshapes include data on energy usage and GHG impacts. GHG impacts in ResStock are derived from the NREL Cambium dataset. 17 The electric grid emissions used are marginal emissions averaged over a 15year time horizon under cambium’s mid-case forecast scenario. The hourly emission values in this dataset are provided at the month-hour level, i.e., the forecasted emissions in each month are averaged for each hour of the day in that month. This methodology captures monthly and diurnal changes in electric grid GHG emissions but does not allow for a direct comparison between temperature and emission rates. 18 Emission intensity for natural gas and propane was sourced from ResStock and includes methane leakage from the natural gas system, expressed in CO2e. For all modeling, heat pumps were sized to cover cooling design loads typical of the Front Range region of Colorado (e.g. 2 to 3 tons cooling capacity). For households in climate zones 6B and 7, sizing for design cooling load according to standard sizing procedures (Manual J and Manual S) often results in the selection of very small heat pumps (smaller than is typically available for purchase). The number of households with CAC systems that are located in climate zones 6B and 7 is not very high, and the team assumes these homes are likely large in size, with above average cooling load requirements. Thus, the team assumed households with CACs in climate zones 6B and 7 would also utilize heat pumps sized to cover typical Front Range cooling loads. Note that sizing a heat pump to cover cooling load will typically result in a heat pump installation that is not capable of meeting the home’s full heating requirements. 16 ResStock includes a file for each model that contains 15 min interval data. The team assembled a database of each of these files, totaling 15-minute interval data for 4,549 models that represent the housing of all impacted residents. This data was summarized by region to create regional loadshapes that account for the housing stock and weather of each region. 17 NREL Cambium dataset 18 It is the authors opinion that this may result in a slight overestimate of emission benefits at lower switchover temperatures and a slight underestimate of emission benefits at higher switchover temperatures due to the expected relationship between the grid’s fraction of clean energy and ambient air temperature.Page 26 of 147
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 23 Page 26 of 147 Thus, we assume all households retain their existing heating systems and use them for backup or supplemental heat in dual fuel configurations (in homes with natural gas or propane furnaces) or all-electric heating systems (in homes with electric resistance heating systems). The regional 8760 energy and emission loadshapes were paired with a minimum efficiency heat pump (meHP) and cold-climate heat pump (ccHP) performance models 19 to estimate energy consumption, annual heating costs, and GHG emissions of the heat pumps when operated in dual fuel systems with differing switchover temperatures. The switchover temperature is the temperature at which the thermostat is programmed to switch from heating with the heat pump to heating with the natural gas or propane furnace in dual fuel heating systems. Heat pump performance and economics in households with existing electric resistance space heating systems were modeled without any heat pump switchover temperature and without setback-induced increases in electric resistance heating. As a result, in these all-electric heating systems, the heat pump was assumed to operate whenever it was capable of outputting heat (down to -5 degrees F for meHPs and -15 degrees F for ccHPs). The electric resistance heating system was modeled to supplement the heat pump when the heat pump heating output was lower than the building heat load. For meHPs, the range of switchover temperature examined was 20 to 50 degrees F. For ccHPs, switchover temperatures between 5 and 50 degrees F were examined. Below these minimum temperatures, a heat pump installed in a CAC-replacement scenario with no ductwork modifications or electrical infrastructure upgrades will likely have insufficient heating capacity to meet the building heating load. Thus, the team assumed the existing gas or propane furnace supplies all heating when the outdoor temperature is below the switchover temperature. At switchover 19 Equipment performance maps for modeled meHPs (Carrier 25SPA5) and ccHPs (Carrier 25VNA8) were used to develop an equipment performance model. Carrier publishes expanded product performance maps in a way that most other manufacturers do not.Page 27 of 147
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 23 Page 27 of 147 temperatures of 50 degrees F, the heat pump is only supplying a marginal amount of the annual heating load for the residential building. The team then determined the economically optimal switchover temperature for each heating system type in each Geographic Analysis Region, where the economically optimal switchover temperature is defined as the switchover temperature within the allowed range that provided the lowest annual heating utility bill. For the economic and GHG emission reduction impact analysis, the team assumed that households in each region would utilize the economically optimal switchover temperature when operating their heating system over the lifetime of the heat pump. The Residential CAC Standard analyzed does not require that households operate their heat pump heating systems with any particular switchover temperature and does not even explicitly require that the household utilize the heat pump for heating. The standard simply requires that a heat pump is installed instead of a CAC. That said, the team believes it is fair to assume that households will operate their heat pump system in an economically optimal manner that reduces heating utility bills. Figure 1 below shows the estimated annual heating cost for a dual fuel heating system composed of a meHP and 80% annual fuel utilization efficiency (AFUE) natural gas furnace for a range of switchover temperatures for various Geographic Analysis Regions. Regions with high natural gas costs (e.g. climate zone 6B-Mountains, Morgan County Area) have lower heating costs at lower switchover temperatures, while regions with low natural gas costs (e.g. El Paso County) have lower heating costs with higher switchover temperatures.Page 28 of 147
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 23 Page 28 of 147 1,200 Annual Cost of Heating ($) 1,000 800 600 400 200 0 20 25 Southeastern Colorado 6B Mountain 7B High Mountain Denver County El Paso_Fremont_Teller Morgan Area 30 35 40 45 50 Dual Fuel Switchover Temperature (°F) Figure 1. Annual heating cost as a function of switchover temperature. The Dual fuel heating system is composed of a meHP and 80% AFUE natural gas furnace. Table 7 and Appendix Table 33 summarize the economically optimal switchover temperature for dual fuel heating system combinations in each Geographic Analysis Region, for natural gas and propane heating systems, respectively. The switchover temperature for natural gas dual fuel heating systems varies significantly between Geographic Analysis Region, showing that there is geographic variation for when it is more economical to operate a heat pump or a natural gas furnace. On the other hand, propane dual fuel systems have switchover temperatures of 20 degrees F and 5 degrees F for meHPs and ccHPs, respectively, in 15 out of 16 regions showing that it is nearly always economically optimal to operate a heat pump instead of a propane furnace. ccHPs generally have lower economically optimal switchover temperatures when compared to meHPs, because ccHPs are frequently more efficient than meHPs, especially at temperatures below 20 degrees F. In addition, homes with 80% efficient furnaces have lower switchover temperatures, because the heat pump provides higher natural gas savings when paired with lower efficiency furnaces.Page 29 of 147
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 23 Page 29 of 147 Table 7. Calculated economically optimal switchover temperatures for dual fuel heating systems utilizing natural gas as the heating fuel meHP + meHP + ccHP + ccHP + 80% AFUE 96% AFUE 80% AFUE 96% AFUE Nat. Gas Nat. Gas Nat. Gas Nat. Gas Furnace Furnace Furnace Furnace Southeastern Colorado 45 50 40 45 6B Mountain 20 20 5 5 7B High Mountain 40 50 25 40 Adams County 35 45 30 35 Arapahoe County 35 45 30 35 Boulder_Broomfield_Gilpin 35 45 30 40 Denver County 35 45 30 35 Douglas_Elbert 35 50 25 35 El Paso_Fremont_Teller 50 50 45 50 Jefferson County 35 45 30 40 La Plata_Montezuma 45 50 40 45 Larimer County 30 45 25 30 Mesa Area 35 45 25 35 Morgan Area 20 20 10 15 Pueblo Area 35 45 30 40 Weld County 30 40 25 30 Geographic Analysis RegionPage 30 of 147
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 23 Page 30 of 147 In addition to the impacts on heating utility bills, the team calculated cooling utility bill savings based on the higher federal minimum efficiency standard for heat pumps compared to air conditioners. A minimum seasonal energy efficiency ratio (SEER2) value of 14.3 was used for heat pumps and a minimum SEER2 value of 13.4 20 was used for CACs. After calculating the economics and GHG emission impacts for each CAC installation type at the Geographic Analysis Region level, the team used the distribution of households with each heating system efficiency level and fuel type from ResStock to weigh the average per household impacts for each region to a statewide level. 20 EIA, Efficiency requirements for residential central AC and heat pumps to rise in 2023
As listed on the current system
Question(s) Answered 11 (Connecticut Light and Power Company dba Eversource Energy) Date Filed: 08/27/2026