Interrogatory responses
Answers to questions 11
Filed by Connecticut Light and Power Company dba Eversource Energy2 files
Part of docket 26-05-10Files2
CLF-011 Attachment 23.pdf
PDF · 16 MB · 147 pagesText searchable
Download CLF-011 Attachment 23.pdfRead the text of CLF-011 Attachment 23.pdf
CLF-011 Attachment 24.pdf
PDF · 1.8 MB · 6 pagesText searchable
Download CLF-011 Attachment 24.pdfRead the text of CLF-011 Attachment 24.pdf
Page 28 of 147
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 23 Page 28 of 147 1,200 Annual Cost of Heating ($) 1,000 800 600 400 200 0 20 25 Southeastern Colorado 6B Mountain 7B High Mountain Denver County El Paso_Fremont_Teller Morgan Area 30 35 40 45 50 Dual Fuel Switchover Temperature (°F) Figure 1. Annual heating cost as a function of switchover temperature. The Dual fuel heating system is composed of a meHP and 80% AFUE natural gas furnace. Table 7 and Appendix Table 33 summarize the economically optimal switchover temperature for dual fuel heating system combinations in each Geographic Analysis Region, for natural gas and propane heating systems, respectively. The switchover temperature for natural gas dual fuel heating systems varies significantly between Geographic Analysis Region, showing that there is geographic variation for when it is more economical to operate a heat pump or a natural gas furnace. On the other hand, propane dual fuel systems have switchover temperatures of 20 degrees F and 5 degrees F for meHPs and ccHPs, respectively, in 15 out of 16 regions showing that it is nearly always economically optimal to operate a heat pump instead of a propane furnace. ccHPs generally have lower economically optimal switchover temperatures when compared to meHPs, because ccHPs are frequently more efficient than meHPs, especially at temperatures below 20 degrees F. In addition, homes with 80% efficient furnaces have lower switchover temperatures, because the heat pump provides higher natural gas savings when paired with lower efficiency furnaces.Page 29 of 147
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 23 Page 29 of 147 Table 7. Calculated economically optimal switchover temperatures for dual fuel heating systems utilizing natural gas as the heating fuel meHP + meHP + ccHP + ccHP + 80% AFUE 96% AFUE 80% AFUE 96% AFUE Nat. Gas Nat. Gas Nat. Gas Nat. Gas Furnace Furnace Furnace Furnace Southeastern Colorado 45 50 40 45 6B Mountain 20 20 5 5 7B High Mountain 40 50 25 40 Adams County 35 45 30 35 Arapahoe County 35 45 30 35 Boulder_Broomfield_Gilpin 35 45 30 40 Denver County 35 45 30 35 Douglas_Elbert 35 50 25 35 El Paso_Fremont_Teller 50 50 45 50 Jefferson County 35 45 30 40 La Plata_Montezuma 45 50 40 45 Larimer County 30 45 25 30 Mesa Area 35 45 25 35 Morgan Area 20 20 10 15 Pueblo Area 35 45 30 40 Weld County 30 40 25 30 Geographic Analysis RegionPage 30 of 147
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 23 Page 30 of 147 In addition to the impacts on heating utility bills, the team calculated cooling utility bill savings based on the higher federal minimum efficiency standard for heat pumps compared to air conditioners. A minimum seasonal energy efficiency ratio (SEER2) value of 14.3 was used for heat pumps and a minimum SEER2 value of 13.4 20 was used for CACs. After calculating the economics and GHG emission impacts for each CAC installation type at the Geographic Analysis Region level, the team used the distribution of households with each heating system efficiency level and fuel type from ResStock to weigh the average per household impacts for each region to a statewide level. 20 EIA, Efficiency requirements for residential central AC and heat pumps to rise in 2023Page 31 of 147
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 23 Page 31 of 147 Estimated Household-Level Impacts To estimate the household impacts of a Residential CAC Standard in Colorado, the team examined the upfront incremental cost of heat pumps, modeled operating costs for heat pumps for space heating and cooling, estimated changes in overall electricity and natural gas or propane use after heat pump installation, and estimated changes in GHG emissions per household. Heat pump upfront incremental cost The team relied on a secondary literature review, interviews with market experts, and contractor focus groups to estimate heat pump costs. The team estimates the total installed cost of a 3-ton ducted meHP (SEER2 = 14.3) to be $2,200 higher than the cost of a 3-ton minimum efficiency central air conditioner (meCAC) installed alongside the existing heating system. 21 This estimate was determined by averaging incremental cost estimates from a variety of sources as shown in Table 8. The average incremental cost was determined to be roughly $2,200 (rounded down from $2,232). The higher costs for the heat pump reflect higher equipment efficiency (SEER2 of 14.3 vs. 13.4), additional components to allow heat pump operation (e.g. reversing valve and defrost controls), and slightly higher installation costs. HVAC contractors were asked to compare the installation process for a heat pump and an CAC, and they responded that the primary difference was the potential need for a new thermostat and/or need for a different control wire between the heat pump outdoor condenser and indoor unit (or from the thermostat to the indoor unit). Thus, the team expects the labor cost differences between a meHP and a meCAC to be small but non-zero in many cases. 21 Costs are expected to vary depending on local labor conditions and home and heating system type, but it was beyond the scope of this study to develop individual cost models for all 16 analysis regionsPage 32 of 147
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 23 Page 32 of 147 Table 8. Data and sources used to estimate the incremental cost of a meHP Source Heat Pumps in the Northeast and Mid- Atlantic: Costs and Market Trends, 2024 TECH Clean California Incremental Cost Study, 2024 Cool Way to Heat Homes, 2024 meCAC Cost meHP Cost Incremental 13-14 SEER2 14-15 SEER2 Cost of meHP $4,140 $7,200 $3,060 $9,777 $11,201 $1,424 $6,546 $8,503 $1,957 $5,891 $8,562 $2,671 $7,522 $9,195 $1,673 N/A N/A $1,350 22 $5,310 $6,810 $1,500 $6,000 $7,443 $1,443 $2,960 $8,485 $5,525 $4,301.60 23 $6,018.75 $1,717.16 Heat pumps for all? Distributions of the costs and benefits of residential air-source heat pumps in the United States, 2024 Xcel 2024-2026 Demand-Side Management & Beneficial Electrification Plan, 2023 Investigation of Air Source Heat Pumps as a Replacement of Central Air Conditioning, 2022 EIA – Technology Forecast Updates – Residential and Commercial Building Technologies – Advanced Case, 2023 The Cost of Decarbonization and Energy Upgrade Retrofits for US Homes, 2021 2023 Illinois Statewide Technical Reference Manual, V11.0, 2023 Wholesale equipment price data from RMI 22 23 Determined using the average of the wholesale price and project bid methods Full installation cost estimated by adding a 40% margin on top of equipment costPage 33 of 147
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 23 Page 33 of 147 For ccHPs, the team estimates the incremental cost of a 3-ton ccHP over a 3-ton meCAC is $6,600. There is significant diversity in ccHP equipment price and capability so estimating a single incremental price is difficult. That said, when possible, the team tried to identify price estimates for heat pumps that met the ENERGY STAR cold-climate heat pump specification and had SEER2 between 15.2 and 20. The team also tried to identify price data that did not include the cost of supplemental heating systems, ductwork modifications, or electrical upgrades. The price data used to determine the $6,600 incremental price is shown in Table 9. The incremental cost for a ccHP is expected to be higher than that of a meHP because ccHPs typically have inverter compressor technology and higher SEER2. Based on conversations with HVAC contractors, ccHP systems in Colorado are currently used primarily in full heating system electrification projects or new dual fuel heating systems as opposed to scenarios where a CAC is replaced with a ccHP. That said, ccHPs were still modeled herein because there is likely no technical factor that would prevent a household from installing a ccHP and using it alongside their existing heating system. Table 9. Data and sources used to estimate the incremental cost of installing a ccHP Source Xcel 2024-2026 Demand-Side Management & Beneficial Electrification Plan, 2023 meCAC Cost ccHP Cost Incremental 13-14 SEER2 15-20 SEER2 Cost of ccHP $7,522 $17,739 $10,217 $5,891 $12,900 24 $7,009 $4,913 $13,200 $8,287 N/A N/A $7,860 25 Heat pumps for all? Distributions of the costs and benefits of residential air-source heat pumps in the United States, 2024 Heat Pumps Pay Off, Unlocking lower-cost heating and cooling in Canada, 2023 Investigation of Air Source Heat Pumps as a 24 25 Price estimate taken from Figure 7, assuming a heating seasonal performance factor of 11.0 Determined using the average of the wholesale price and project bid methodsPage 34 of 147
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 23 Page 34 of 147 Source meCAC Cost ccHP Cost Incremental 13-14 SEER2 15-20 SEER2 Cost of ccHP $5,310 $6,940 $1,630 $4,301.60 26 $8,901.47 $4,599.87 Replacement of Central Air Conditioning, 2022 EIA – Technology Forecast Updates – Residential and Commercial Building Technologies – Advanced Case, 2023 Wholesale equipment price data from RMI When modeling the economics of meHPs and ccHPs, the team assumed no rebates or tax credits were used to offset incremental installation and equipment costs for heat pumps. This assumption was made because there is uncertainty in incentive levels over the 18-year time frame examined in this analysis. Utility and local government rebate levels frequently change from year to year and equipment efficiency requirements tend to change over time. However, rebates and tax credits are currently an important piece of the HVAC ecosystem in Colorado with significant incentives available for many households that install heat pumps. Thus, their impact on heat pump economics is discussed in a later section of this white paper. Economic impacts after heat pump installation Space heating and cooling system operating costs, energy use, and GHG emissions were calculated for each equipment scenario in each Geographic Analysis Region. All households in Colorado are found to realize annual heating and cooling bill savings after installation of a meHP or ccHP instead of a meCAC (when the meHP is operated in an economically optimal manner). That said, the specific amount of utility bill savings is not evenly distributed across households. An estimated 82% of households realize annual utility bill savings of $50 or less after installing a meHP, as shown in 26 Full installation cost estimated by adding a 40% margin on top of equipment costPage 35 of 147
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 23 Page 35 of 147 Figure 2. The other 18% of Colorado households see much more significant utility bill savings after installing a meHP, with 3% of households saving between $50 and $500 per year, 2% of households saving between $500 and $1,000 per year, and 13% of households saving over $1,000 per year. When the annualized incremental meHP cost of $122/year is added to the annual utility bill savings, the resulting annual total savings are negative (an added cost) for 82% of households and positive (savings) for the other 18% of households. The primary conclusion from this data is that the annual total savings potential after a heat pump installation is divided into two primary cohorts. One cohort of Colorado households (≈80% of households) sees a modest annual total cost increase after installing a meHP instead of a meCAC and the other cohort (≈20% of households) sees large annual savings after installing a meHP. Decreasing the upfront incremental cost of installing a heat pump would play a large role in improving heat pump economics and making installation of a meHP economically positive for all Colorado households. $2,000 Annual Utility Bill Savings Annual Household Savings ($) $1,750 Annual Total Savings $1,500 $1,250 $1,000 $750 $500 $250 $0 -$250 0% 20% 40% 60% 80% 100% Portion of Colorado Households Figure 2. Distribution of annual heating and cooling utility bill savings and annual total savings for Colorado households that install a meHP instead of a meCACPage 36 of 147
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 23 Page 36 of 147 The key driver behind this uneven distribution of savings is the fuel used by the existing heating systems in each household. Figure 3 breaks down the economic impacts of the Residential CAC Standard by the number of households with each heating fuel type (either natural gas, propane, or electricity). The household economic impacts of the Residential CAC Standard depend strongly on household existing heating fuel. Most Colorado households use natural gas furnaces for space heating, and these households see a modest increase in annual total costs ($0 to $100) after installing a meHP instead of a meCAC. Households with existing propane furnace heating systems realize significant annual total savings ($375 to $1,500) after installing a meHP and the incremental cost of the heat pump is paid back within only a few years. The economic value of installing a meHP is even stronger for households with existing electric resistance space heating systems. These households see annual total savings of $750 to $2,000 and would have their investments in a meHP recovered within 1 or 2 two years. Thus, households with a CAC and propane furnace or electric resistance heating system should install a heat pump when their existing CAC reaches end life if they aim to optimize for the lowest annual total heating and cooling costs. These households would see significant savings over the expected 18-year lifetime of the installed heat pump.Page 37 of 147
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 23 Page 37 of 147 1,000,000 Number of Colorado Households Existing Natural Gas Furnace 800,000 Existing Propane Furnace Existing Electric Resistance Heating 600,000 400,000 200,000 0 Annual Household Utility Bill Savings Figure 3. Number of Colorado households, organized by existing heating fuel, as a function of annual utility bill savings after a meHP is installed instead of a meCAC Regional breakdown: annual utility bill savings Using the electricity and fuel prices as laid out in Table 6, the annual utility bill savings per household associated with installing a heat pump alongside different existing heating equipment were calculated for all 16 Geographic Analysis Regions. Heating and cooling utility bill savings for Colorado households that install a meHP and ccHP are shown in Table 10 and Table 11, respectively. Note that these utility bill savings metrics do not account for the incremental cost of a heat pump vs. a meCAC. For both meHPs and ccHPs, heating utility bill savings are highly variable across different regions, primarily because of variability in natural gas prices and secondarily because annual heating loads vary across regions. The cooling utility bill savings are less variable given that electricity rates are fairly stable across the different regions
As listed on the current system
Question(s) Answered 11 (Connecticut Light and Power Company dba Eversource Energy) Date Filed: 08/27/2026