The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 23 Page 51 of 147 27 some cases. Other studies have also identified that rate structures play a significant role in decreasing the operating costs for heat pumps. 28,29,30 SB24-214, passed by Colorado General Assembly in 2024, requires that investor-owned utilities in Colorado develop proposals for electric rate structures that are designed to lower the average monthly energy bill for residential households that utilize heat pumps as their primary heating source. These proposed rate structures must be submitted to the Colorado Public Utilities Commission by August 1, 2027. In Colorado, the largest utility by number of customers is Xcel Energy. Xcel Energy currently provides a decreased electricity price to residential customers in the winter when heat pump usage is highest but does not offer a specialized residential electric heat rate structure. The municipal utility in Fort Collins and Wheatland Electric Cooperative, located in Eastern Colorado, currently offer electric heat rate structures in Colorado. However, the number of households receiving electric services from these two entities is small (less than 5% of households in Colorado). If more Colorado utilities and cooperatives begin to offer electric heat rate structures, the operating costs for heat pumps would be reduced and heat pumps would become more attractive to many households. Heat pump rebates and tax credit Incentives Rebates and tax credits are currently an important piece of the HVAC ecosystem in Colorado with significant incentives available for many households that install heat pumps. Exact incentive levels vary depending on household location, what heat pump equipment is installed, and household income level and tax liability. Due to this variability, the team modeled the economic effects of general upfront incentive amounts as opposed to modeling specific scenarios where current utility and local government rebates are stacked with federal and state tax credits. 27 It's time to stop overcharging heat pump customers. Electrified Heating Rates Can Help. Massachusetts Study on Time-Varying Rate Design to Enable Electrification 29 Electricity Rates that Keep Bills Down after Electrification of Home Heating 30 Heat Pump–Friendly Cost-Based Rate Designs 28Page 52 of 147
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 23 Page 52 of 147 As shown previously, the economics for heat pump installations in households with existing propane furnace or electric resistance heating systems are highly favorable in all regions of Colorado. Regardless of heat pump incentive availability, these households should install heat pumps instead of CACs if they aim to reduce their overall space heating and cooling costs. Households with natural gas heating systems, however, have less favorable heat pump economics (with current natural gas and electric prices). Thus, this analysis of incentives and payback periods was only performed for households that have existing natural gas heating systems. Payback period is calculated by dividing the incremental cost of the heat pump ($2,200 for a meHP and $6,600 for a ccHP) by the sum of the annual heating and cooling utility bill savings the heat pump provides. The heat pump equipment lifetime is assumed to be 18 years, so payback periods longer than 18 years represent situations where the household does not break even or save money after installing a heat pump instead of a meCAC. Table 15 shows how upfront incentives change the economics for meHP installations in households that have existing 96% AFUE natural gas furnaces for space heating (results for households with 80% AFUE natural gas furnaces are shown in Appendix Table 34). Without any upfront incentive, the payback periods for households in most regions of Colorado are over 100 years. The exceptions are the 6B Mountain and Morgan Area regions, which have payback periods less than 18 years without any incentives. These two regions have favorable ratios of electric to natural gas price and households in these regions would save money if they installed heat pumps instead of CACs, even with no upfront incentives. Households with 96% AFUE furnaces have longer payback periods than households with 80% AFUE furnaces because the potential heating utility bill savings are reduced when using the higher efficiency furnace. For households with 96% AFUE natural gas furnaces, an upfront incentive of $1,600 results in payback periods shorter than 18 years in only 2 out of 16 Geographic Analysis Regions. Increasing the upfront incentive to $2,000 brings the payback period below 18 years in 15 out of 16 regions for the 96% AFUE furnace scenario. WhenPage 53 of 147
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 23 Page 53 of 147 paired with an 80% AFUE natural gas furnace, a meHP has a payback period shorter than 18 years in 12 out of 16 Geographic Analysis Regions when an upfront incentive of $1,600 is available. An upfront incentive of approximately $2,000 is required for all regions to see payback periods shorter than 18 years. Thus, for the Residential CAC Standard to provide total savings or breakeven economics for most Colorado households, an upfront incentive of approximately $2,000 would be required for meHP installations. Table 15. Payback period for the $2,200 incremental investment required to install a meHP instead of a meCAC (96% AFUE natural gas furnace dual fuel heating system) Payback Payback Payback Payback Payback Payback Period Period Period Period Period Period Geographic Analysis (Years), (Years), (Years), (Years), (Years), (Years), Region $0 $400 $800 $1,200 $1,600 $2,000 Upfront Upfront Upfront Upfront Upfront Upfront Incentive Incentive Incentive Incentive Incentive Incentive Southeastern Colorado 100 82 64 45 27 9 6B Mountain 10 8 6 5 3 1 7B High Mountain 440 360 280 200 120 40 Adams County 110 90 70 50 30 10 Arapahoe County 100 82 64 45 27 9 Boulder_Broomfield_Gilpin 116 95 74 53 32 11 Denver County 105 86 67 48 29 10 Douglas_Elbert 129 106 82 59 35 12 El Paso_Fremont_Teller 169 138 108 77 46 15 Jefferson County 122 100 78 56 33 11Page 54 of 147
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 23 Page 54 of 147 Payback Payback Payback Payback Payback Payback Period Period Period Period Period Period Geographic Analysis (Years), (Years), (Years), (Years), (Years), (Years), Region $0 $400 $800 $1,200 $1,600 $2,000 Upfront Upfront Upfront Upfront Upfront Upfront Incentive Incentive Incentive Incentive Incentive Incentive La Plata_Montezuma 183 150 117 83 50 17 Larimer County 116 95 74 53 32 11 Mesa Area 85 69 54 38 23 8 Morgan Area 12 10 7 5 3 1 Pueblo Area 85 69 54 38 23 8 Weld County 100 82 64 45 27 9 Table 16 shows the payback economics for ccHP installations in households that have 96% AFUE natural gas furnace heating systems (Appendix Table 35 shows results for 80% AFUE natural gas furnace scenarios). For both 96% and 80% AFUE furnace efficiency scenarios an upfront incentive of approximately $6,000 is required for households in all Geographic Analysis Regions to realize payback periods 18 years or shorter. A smaller incentive of $5,000 results in payback periods shorter than 18 years in 13 out of 16 Geographic Analysis Regions for the 80% AFUE natural gas furnace scenario and 12 out of 16 Geographic Analysis Regions for the 96% AFUE natural gas furnace scenario. Thus, incentivizing ccHP installations in CAC replacement scenarios in households with natural gas heating systems requires an incentive that is roughly 3 times larger than the incentive required to make meHP installations economical for the same scenarios ($6,000 vs. $2,000).Page 55 of 147
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 23 Page 55 of 147 Table 16. Payback period for the $6,600 incremental investment required to install a ccHP instead of a meCAC (96% AFUE natural gas furnace dual fuel heating system) Geographic Analysis Region Payback Payback Payback Payback Payback Payback Period Period Period Period Period Period (Years), (Years), (Years), (Years), (Years), (Years), $0 $2,000 $3,000 $4,000 $5,000 $6,000 Incentive Incentive Incentive Incentive Incentive Incentive Southeastern Colorado 59 41 32 23 14 5 6B Mountain 15 10 8 6 4 1 7B High Mountain 194 135 106 76 47 18 Adams County 64 45 35 25 16 6 Arapahoe County 61 42 33 24 15 6 Boulder_Broomfield_Gilpin 62 43 34 25 15 6 Denver County 63 44 35 25 15 6 Douglas_Elbert 83 58 45 33 20 8 El Paso_Fremont_Teller 108 75 59 43 26 10 Jefferson County 70 49 38 28 17 6 La Plata_Montezuma 112 78 61 44 27 10 Larimer County 64 45 35 25 16 6 Mesa Area 51 36 28 20 12 5 Morgan Area 24 17 13 10 6 2 Pueblo Area 54 37 29 21 13 5 Weld County 64 45 35 25 16 6Page 56 of 147
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 23 Page 56 of 147 In 2025, there are significant heat pump rebates available to many Colorado households. Table 17 summarizes many of the available rebates for both standard efficiency heat pumps and ccHPs. Note that nearly all incentive programs currently require that standard heat pumps have a SEER2 rating of at least 15.2 and heating seasonal performance factor (HSPF2) rating of at least 7.8, which are both higher than the federal minimum values of 14.3 and 7.5, respectively. Thus, the standard heat pumps eligible for most of these incentives are at least ~5% more efficient at heating and cooling than the meHP modeled in this white paper. The incremental cost estimate of $2,200 applies specifically to meHPs, but the components required to manufacture a standard heat pump with SEER2 of 15.2 and HSPF2 of 7.8 are likely only slightly more expensive than the components required to manufacture a meHP. The ccHP modeled in this white paper would likely qualify for the ccHP rebates listed here in most installation scenarios. In many regions of Colorado, the current rebate level for standard heat pumps is similar to the $2,000 estimated upfront incentive required to make installing a meHP instead of a meCAC economical for households with natural gas heating. Thus, combining a utility rebate with a local government rebate or tax credit likely makes standard heat pumps economically competitive for most Colorado households with current incentive levels. The rebates available for ccHPs, however, are generally significantly lower than the $6,000 estimated upfront incentive required to make installing a ccHP instead of a meCAC economical for households with natural gas heating. One exception is that households with electric or gas service from Xcel Energy can currently receive a $5,400 rebate for a ccHP and can potentially stack that rebate with a local government rebate (from a community like Golden, Boulder, Denver, etc.) and a tax credit to reach an overall incentive level above the $6,600 incremental cost of a ccHP. In general, though, in situations where a CAC is being replaced by a heat pump, it is currently most economically advantageous for Colorado households to install standard heat pumps as opposed to ccHPs. That said, in situations where the full heating and cooling system in a home are being replaced, or in new construction situations, the economics of ccHPs improve because one canPage 57 of 147
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 23 Page 57 of 147 potentially avoid installing a furnace and can rely on the ccHP to provide all heating and cooling. Table 17. Upfront heat pump incentive levels for various programs in Colorado (retrieved in May 2025, not exhaustive) Incentive Incentive for Incentive for Type Standard Heat Pump ccHP Rebate $2,700 $5,400 Rebate $1,500 $2,000 Colorado Spring Utility 33 Rebate $1,500 $3,000 Black Hills Energy 34 Rebate $1,500 $2,500 United Power 35 Rebate $2,500 $2,500 Holy Cross Energy 36 Rebate Not Offered $3,000 Poudre Valley REA 37 Rebate $1,800 $1,800 Rebate $1,500 $1,500 Rebate $1,500 $3,000 Entity Providing Incentive Xcel Energy 31 Platte River Power Authority (Efficiency Works) 32 La Plata Electric Association 38 Gunnison County Electric 31 Standard heat pump must have SEER2 of 15.2 and HSPF2 of 7.8, $2,700 value assumes 3 tons of cooling capacity at 95 °F, $5,400 value assumes a ccHP that maintains 80% heating capacity at 5 °F 32 Standard heat pump minimum 15.2 SEER2 and 7.8 HSPF2, ccHP must be sized for 100% of the design heating load 33 Standard heat pump minimum 15.2 SEER2 and 7.8 HSPF2, ccHP must be NEEP certified 34 Standard heat pump minimum 15.2 SEER2, ccHP minimum SEER2 of 16.0 35 Standard heat pump minimum 15.2 SEER2 and 8.1 HSPF2, assuming 3 tons in size 36 25% of the total project cost, up to $3,000 total 37 Standard heat pump minimum of 7.8 HSPF2 38 Minimum HSPF2 of 8.5, assuming heat pump with 3 tons of heating capacity at 47 °FPage 58 of 147
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 23 Page 58 of 147 Incentive Incentive for Incentive for Type Standard Heat Pump ccHP City and County of Denver Rebate Not Offered $1,200 City of Golden Rebate Not Offered $2,000 City of Boulder 40 Rebate $750 $900 State of Colorado Heat Tax Pump Tax Credit 41 Credit $500-1,500 $500-1,500 Entity Providing Incentive Association 39 When evaluating how upfront incentives can lessen the household financial burden caused by a Residential CAC Standard, it is important to also consider the potential budget required to maintain incentive programs. As shown in Table 2, an estimated 81,684 heat pumps would be installed per year if a Residential CAC Standard were put in place in Colorado. If these were all meHPs and a $2,000 incentive was provided to each impacted household, the annual incentive budget required would be approximately $163 million. If these were instead all ccHPs and a $6,000 incentive was provided for each installation, the required annual budget would be approximately $490 million. If incentives were only provided to households with existing natural gas heating systems, which have less favorable heat pump operating economics, these theoretical annual incentive budgets could be reduced by 15% (incentives only provided for 69,507 annual heat pump installations). If instead incentives were only provided to households with income below 80% area median 39 Standard heat pump minimum 15.2 SEER2 and 7.8 HSPF2 Minimum HSPF2 of 7.8 for standard heat pump, assuming 3 tons for ccHP and standard heat pump 41 The state tax credit is claimed by the installing HVAC contractor, but the contractor must pass on at least 33% of the tax credit to the customer as an upfront discount. Heat pumps must be ENERGY STAR certified and must meet other system sizing/design requirements to qualify. 40Page 59 of 147
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 23 Page 59 of 147 income, the annual incentive budget would likely be reduced by 60-70% (incentives for 25,000 to 33,000 heat pump installations). In 2024 in Colorado, the number of heat pump rebates provided to households by utilities was between 7,000 and 10,000. 42 Thus, the scale of existing incentive programs in Colorado would need to grow significantly if the goal was to provide an incentive to any household that would otherwise realize a negative economic impact because of a Residential CAC Standard. Household Energy and GHG Impacts As discussed previously, differences in the electricity-to-fuel price ratio determine heat pump economics, which in turn affect the economically optimal switchover temperature for a dual fuel heating system. How frequently a heat pump is utilized for heating plays a primary role in determining how large energy saving and GHG emission reduction impacts will be. The household level electricity usage impacts when a meHP or ccHP are installed instead of a meCAC are shown in Table 18 and Appendix Table 36, respectively. Electricity impacts are displayed as percentage changes compared to total household electricity usage in Table 19 and Appendix Table 39 for meHP and ccHP scenarios, respectively. In all cases, heating systems are modeled assuming the heat pump is operated for heating whenever the outdoor temperature is above the economically optimal switchover temperature. Annual electricity usage from space heating increases in households with natural gas heating systems in all regions, but the increases are generally modest, between 500 and 1,500 kWh depending on furnace efficiency for meHP scenarios (5% to 30% increase in electricity usage). In households that have propane furnace heating systems, the annual electricity usage increases more significantly after installation of a heat pump, by roughly 4,000 kWh or a 50% increase in overall usage. Because propane is more expensive than natural gas, dual fuel systems that use propane have a lower economically optimal switchover temperature and use the heat pump to cover a greater portion of the building’s 42 Based on data provided to the Colorado Energy Office by Colorado utilitiesPage 60 of 147
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 23 Page 60 of 147 annual heating needs. For households with existing electric resistance heating, utilizing a heat pump for space heating drives very significant electricity savings, around 11,000 kWh per year (roughly 50% decrease in usage). In general, heat pumps are 2-4 times more efficient at heating when compared to electric resistance heating. Thus, it is expected that using a heat pump instead of electric resistance heating will drive deep reductions in electricity usage. All households see small reductions in electricity usage for space cooling (1% to 2% decrease in overall electricity usage), which is a result of heat pumps having a higher federal minimum SEER2 than CACs. The findings for ccHPs follow similar trends to those identified for meHPs. However, ccHP dual fuel systems have lower economically optimal switchover temperatures than meHP dual fuel systems, so the electricity usage increases for households that have natural gas or propane heating systems are magnified. Electricity usage increases are most drastic after installation of a ccHP for households that utilize a 96% AFUE furnace with natural gas. Because ccHPs can operate efficiently at lower temperatures, households with electric resistance heating systems see a slightly larger decrease in electricity usage when they utilize a ccHP, compared to a meHP. For space cooling, the ccHP delivers greater electricity usage savings when compared to the meHP because the ccHP used for this analysis had a higher SEER2 than the federal minimum.
As listed on the current system
Question(s) Answered 11 (Connecticut Light and Power Company dba Eversource Energy) Date Filed: 08/27/2026