Skip to main content

A prototype public docket site for the Connecticut Public Utilities Regulatory Authority

Utility Dockets and Filings

Interrogatory responses

Answers to questions 11

ResponseFiled by Connecticut Light and Power Company dba Eversource Energy2 files
Part of docket 26-05-10Open
  • Electric
Application of The Connecticut Light and Power Company d/b/a Eversource Energy to Amend its Rate Schedules

Files2

  1. Page 58 of 147

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 23 Page 58 of 147 Incentive Incentive for Incentive for Type Standard Heat Pump ccHP City and County of Denver Rebate Not Offered $1,200 City of Golden Rebate Not Offered $2,000 City of Boulder 40 Rebate $750 $900 State of Colorado Heat Tax Pump Tax Credit 41 Credit $500-1,500 $500-1,500 Entity Providing Incentive Association 39 When evaluating how upfront incentives can lessen the household financial burden caused by a Residential CAC Standard, it is important to also consider the potential budget required to maintain incentive programs. As shown in Table 2, an estimated 81,684 heat pumps would be installed per year if a Residential CAC Standard were put in place in Colorado. If these were all meHPs and a $2,000 incentive was provided to each impacted household, the annual incentive budget required would be approximately $163 million. If these were instead all ccHPs and a $6,000 incentive was provided for each installation, the required annual budget would be approximately $490 million. If incentives were only provided to households with existing natural gas heating systems, which have less favorable heat pump operating economics, these theoretical annual incentive budgets could be reduced by 15% (incentives only provided for 69,507 annual heat pump installations). If instead incentives were only provided to households with income below 80% area median 39 Standard heat pump minimum 15.2 SEER2 and 7.8 HSPF2 Minimum HSPF2 of 7.8 for standard heat pump, assuming 3 tons for ccHP and standard heat pump 41 The state tax credit is claimed by the installing HVAC contractor, but the contractor must pass on at least 33% of the tax credit to the customer as an upfront discount. Heat pumps must be ENERGY STAR certified and must meet other system sizing/design requirements to qualify. 40
  2. Page 59 of 147

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 23 Page 59 of 147 income, the annual incentive budget would likely be reduced by 60-70% (incentives for 25,000 to 33,000 heat pump installations). In 2024 in Colorado, the number of heat pump rebates provided to households by utilities was between 7,000 and 10,000. 42 Thus, the scale of existing incentive programs in Colorado would need to grow significantly if the goal was to provide an incentive to any household that would otherwise realize a negative economic impact because of a Residential CAC Standard. Household Energy and GHG Impacts As discussed previously, differences in the electricity-to-fuel price ratio determine heat pump economics, which in turn affect the economically optimal switchover temperature for a dual fuel heating system. How frequently a heat pump is utilized for heating plays a primary role in determining how large energy saving and GHG emission reduction impacts will be. The household level electricity usage impacts when a meHP or ccHP are installed instead of a meCAC are shown in Table 18 and Appendix Table 36, respectively. Electricity impacts are displayed as percentage changes compared to total household electricity usage in Table 19 and Appendix Table 39 for meHP and ccHP scenarios, respectively. In all cases, heating systems are modeled assuming the heat pump is operated for heating whenever the outdoor temperature is above the economically optimal switchover temperature. Annual electricity usage from space heating increases in households with natural gas heating systems in all regions, but the increases are generally modest, between 500 and 1,500 kWh depending on furnace efficiency for meHP scenarios (5% to 30% increase in electricity usage). In households that have propane furnace heating systems, the annual electricity usage increases more significantly after installation of a heat pump, by roughly 4,000 kWh or a 50% increase in overall usage. Because propane is more expensive than natural gas, dual fuel systems that use propane have a lower economically optimal switchover temperature and use the heat pump to cover a greater portion of the building’s 42 Based on data provided to the Colorado Energy Office by Colorado utilities
  3. Page 60 of 147

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 23 Page 60 of 147 annual heating needs. For households with existing electric resistance heating, utilizing a heat pump for space heating drives very significant electricity savings, around 11,000 kWh per year (roughly 50% decrease in usage). In general, heat pumps are 2-4 times more efficient at heating when compared to electric resistance heating. Thus, it is expected that using a heat pump instead of electric resistance heating will drive deep reductions in electricity usage. All households see small reductions in electricity usage for space cooling (1% to 2% decrease in overall electricity usage), which is a result of heat pumps having a higher federal minimum SEER2 than CACs. The findings for ccHPs follow similar trends to those identified for meHPs. However, ccHP dual fuel systems have lower economically optimal switchover temperatures than meHP dual fuel systems, so the electricity usage increases for households that have natural gas or propane heating systems are magnified. Electricity usage increases are most drastic after installation of a ccHP for households that utilize a 96% AFUE furnace with natural gas. Because ccHPs can operate efficiently at lower temperatures, households with electric resistance heating systems see a slightly larger decrease in electricity usage when they utilize a ccHP, compared to a meHP. For space cooling, the ccHP delivers greater electricity usage savings when compared to the meHP because the ccHP used for this analysis had a higher SEER2 than the federal minimum.
  4. Page 61 of 147

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 23 Page 61 of 147 Table 18. Estimated annual household electricity usage impacts for space heating and cooling when a meHP is installed instead of a meCAC (positive numbers indicate increases in usage) Space Heating Space Heating Space Heating Space Heating 80% AFUE 96% AFUE 80% AFUE 96% AFUE Nat. Gas Nat. Gas Propane Propane Furnace Furnace Furnace Furnace (kWh) (kWh) (kWh) (kWh) Southeastern Colorado 573 302 4,575 4,575 -11,758 -167 6B Mountain 3,508 3,508 3,508 3,508 -12,041 -68 7B High Mountain 450 90 3,998 3,998 -13,938 -122 Adams County 1,334 324 3,899 3,899 -11,110 -114 Arapahoe County 1,445 354 4,206 4,206 -11,874 -121 Boulder_Broomfield_Gilpin 1,888 565 4,839 4,839 -12,935 -107 Denver County 1,483 359 4,333 4,333 -12,184 -114 Douglas_Elbert 1,347 135 3,973 3,973 -11,282 -122 El Paso_Fremont_Teller 183 183 4,084 4,084 -11,657 -91 Jefferson County 1,743 474 4,611 4,611 -12,552 -97 Geographic Analysis Region Space Heating Electric Resistance (kWh) Space Cooling (kWh)
  5. Page 62 of 147

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 23 Page 62 of 147 Space Heating Space Heating Space Heating Space Heating 80% AFUE 96% AFUE 80% AFUE 96% AFUE Nat. Gas Nat. Gas Propane Propane Furnace Furnace Furnace Furnace (kWh) (kWh) (kWh) (kWh) La Plata_Montezuma 179 85 2,980 2,980 -8,696 -88 Larimer County 2,394 370 3,993 3,993 -11,930 -93 Mesa Area 1,153 284 3,833 3,833 -9,667 -154 Morgan Area 4,926 4,926 4,926 4,926 -13,645 -119 Pueblo Area 1,277 375 3,937 3,937 -10,492 -166 Weld County 2,112 676 4,056 4,056 -12,265 -104 Geographic Analysis Region Space Heating Electric Resistance (kWh) Space Cooling (kWh)
  6. Page 63 of 147

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 23 Page 63 of 147 Table 19. Estimated annual household electricity usage impacts for space heating and cooling when a meHP is installed instead of a meCAC (positive numbers indicate increases), percentage changes based on household total electric usage Space Heating Space Heating Space Heating Space Heating Geographic Analysis 80% AFUE 96% AFUE 80% AFUE 96% AFUE Region Nat. Gas Nat. Gas Propane Propane Furnace Furnace Furnace Furnace Southeastern Colorado 7% 4% 56% 56% -39% -2% 6B Mountain 55% 55% 55% 55% -56% -1% 7B High Mountain 8% 2% 69% 69% -55% -2% Adams County 15% 4% 43% 43% -41% -1% Arapahoe County 16% 4% 48% 48% -45% -1% Boulder_Broomfield_Gilpin 22% 7% 57% 57% -47% -1% Denver County 18% 4% 54% 54% -50% -1% Douglas_Elbert 14% 1% 43% 43% -39% -1% El Paso_Fremont_Teller 2% 2% 51% 51% -44% -1% Jefferson County 20% 6% 54% 54% -49% -1% Space Heating Electric Resistance Space Cooling
  7. Page 64 of 147

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 23 Page 64 of 147 Space Heating Space Heating Space Heating Space Heating Geographic Analysis 80% AFUE 96% AFUE 80% AFUE 96% AFUE Region Nat. Gas Nat. Gas Propane Propane Furnace Furnace Furnace Furnace La Plata_Montezuma 3% 1% 46% 46% -32% -1% Larimer County 29% 5% 49% 49% -43% -1% Mesa Area 14% 3% 45% 45% -42% -2% Morgan Area 61% 61% 61% 61% -36% -1% Pueblo Area 15% 4% 46% 46% -49% -2% Weld County 25% 8% 48% 48% -37% -1% Space Heating Electric Resistance Space Cooling
  8. Page 65 of 147

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 23 Page 65 of 147 Natural gas and propane savings for all equipment scenarios and all Geographic Analysis Regions are shown for meHP and ccHP scenarios in Appendix Table 38 and Appendix Table 39 (absolute fuel usage decreases), respectively. Appendix Table 40 and Appendix Table 43 show the same results displayed as percentage reductions based on household total fossil fuel usage. On average, households with 80% AFUE and 96% AFUE natural gas furnaces see fossil fuel use reductions of 16% and 5%, respectively, after installing a meHP. When ccHPs are installed these fuel usage reductions increase to 27% and 13% for 80% AFUE and 96% AFUE furnaces, respectively. However, there is significant variability based on region with natural gas households in 6B Mountain and Morgan Area reducing their natural gas usage by 30% to 40% with meHPs and households in El Paso_Fremont_Teller region only reducing natural gas usage by 2% to 3% with meHPs. Households with propane furnaces see average propane usage reductions of 36% and 40% after meHP installation for 80% AFUE and 96% AFUE furnace scenarios, respectively, and average reductions in propane usage of 58% and 48% after ccHP installation for 80% AFUE and 96% AFUE furnace scenarios, respectively. There is much less variability in propane usage reduction across regions because the delivered propane price is assumed to be the same in all regions of Colorado. In general, the fossil fuel savings are correlated to the previously shown electricity usage impacts because the electricity used by the heat pump for space heating is directly displacing fossil fuels that would have otherwise been used by the existing furnace. ccHPs provide larger reductions in fossil fuel usage for all regions when compared to meHPs, because ccHPs have lower economically optimal switchover temperatures. GHG emission reductions as a percentage of total household emissions for the meHPs and ccHPs scenarios are shown in Table 20 and Table 21, respectively (Appendix Table 42 and Appendix Table 43 show the absolute GHG emission reductions). As expected, GHG emissions reductions are higher for regions and equipment scenarios with stronger heat pump economic situations (lower electricity-to-fuel price ratios and, thus, lower economically optimal switchover temperatures). Households that use
  9. Page 66 of 147

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 23 Page 66 of 147 propane for heating see significant GHG emission reductions of 40-60%, depending on region and furnace efficiency. Households that use electric resistance for heating see slightly lower, but still significant, reductions between 35-55%. For households with natural heating systems, GHG emission reductions are quite variable across the Geographic Analysis Regions examined. Regions with very low natural gas prices (e.g. El Paso_Fremont_Teller) see almost no reduction in GHG emissions regardless of furnace AFUE because the dual fuel switchover temperature is high, and the heat pump is seldom used for heating. Regions with favorable heat economics (6B Mountain and Morgan Area) see reductions of 30-40% for both 80% and 96% AFUE furnaces. The regions with more intermediate natural gas prices only realize GHG reductions of between 4% and 22% in households with 80% AFUE furnaces and 2% and 10% in households with 90% AFUE furnaces. If ccHPs are installed instead of meHPs, the GHG emission reductions are increased for all heating system scenarios in all Geographic Analysis Regions. This result is due to the lower potential switchover temperatures for ccHP systems (5 degrees F instead of 20 degrees F) and the general higher efficiency of the ccHP modeled. Table 20. Percentage reduction of annual household GHG emissions after a meHP is installed instead of a meCAC, by existing heating system type 80% AFUE 96% AFUE 80% AFUE 96% AFUE Electric Nat. Gas Nat. Gas Propane Propane Resistance Furnace Furnace Furnace Furnace Heating Southeastern Colorado 10% 0.3% 63% 50% 40% 6B Mountain 36% 28% 45% 36% 55% 7B High Mountain 6% 0.1% 45% 36% 55% Adams County 16% 4% 49% 39% 43% Arapahoe County 17% 4% 50% 40% 45% Geographic Analysis Region
  10. Page 67 of 147

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 23 Page 67 of 147 80% AFUE 96% AFUE 80% AFUE 96% AFUE Electric Nat. Gas Nat. Gas Propane Propane Resistance Furnace Furnace Furnace Furnace Heating Boulder_Broomfield_Gilpin 22% 7% 57% 46% 48% Denver County 17% 4% 52% 42% 51% Douglas_Elbert 0.3% 0.3% 47% 38% 40% El Paso_Fremont_Teller 0.1% 0.1% 51% 40% 46% Jefferson County 20% 5% 54% 43% 50% La Plata_Montezuma 4% 2% 50% 40% 34% Larimer County 24% 4% 45% 36% 43% Mesa Area 17% 4% 55% 44% 45% Morgan Area 43% 33% 54% 43% 37% Pueblo Area 17% 5% 53% 42% 55% Weld County 22% 7% 46% 37% 39% Geographic Analysis Region Table 21. Percentage reduction of annual household GHG emissions after a ccHP is installed instead of a meCAC, by existing heating system type 80% AFUE 96% AFUE 80% AFUE 96% AFUE Electric Nat. Gas Nat. Gas Propane Propane Resistance Furnace Furnace Furnace Furnace Heating Southeastern Colorado 18% 10% 71% 56% 43% 6B Mountain 54% 42% 69% 54% 58% Geographic Analysis Region

As listed on the current system

Question(s) Answered 11 (Connecticut Light and Power Company dba Eversource Energy) Date Filed: 08/27/2026

This filing on the current system (opens in a new tab)