Interrogatory responses
Answers to questions 11
Files8
CLF-011 Attachment 25.pdf
PDF · 1.7 MB · 5 pagesText searchable
Download CLF-011 Attachment 25.pdfRead the text of CLF-011 Attachment 25.pdf
CLF-011 Attachment 26.pdf
PDF · 876 KB · 4 pagesText searchable
Download CLF-011 Attachment 26.pdfRead the text of CLF-011 Attachment 26.pdf
CLF-011 Attachment 27.pdf
PDF · 1.6 MB · 3 pagesText searchable
Download CLF-011 Attachment 27.pdfRead the text of CLF-011 Attachment 27.pdf
CLF-011 Attachment 28.pdf
PDF · 1.5 MB · 4 pagesText searchable
Download CLF-011 Attachment 28.pdfRead the text of CLF-011 Attachment 28.pdf
CLF-011 Attachment 29.pdf
PDF · 1.7 MB · 5 pagesText searchable
Download CLF-011 Attachment 29.pdfRead the text of CLF-011 Attachment 29.pdf
CLF-011 Attachment 30.pdf
PDF · 4.9 MB · 47 pagesText searchable
Download CLF-011 Attachment 30.pdfRead the text of CLF-011 Attachment 30.pdf
CLF-011 Attachment 31.pdf
PDF · 4.5 MB · 65 pagesText searchable
Download CLF-011 Attachment 31.pdfRead the text of CLF-011 Attachment 31.pdf
CLF-011 Attachment 32.pdf
PDF · 1.6 MB · 11 pagesText searchable
Download CLF-011 Attachment 32.pdfRead the text of CLF-011 Attachment 32.pdf
Text of CLF-011 Attachment 28.pdf
Extracted from the file · 4 pages · 6,964 characters
Text of CLF-011 Attachment 29.pdf
Extracted from the file · 5 pages · 11,434 characters
Page 21 of 47
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 30 Page 21 of 47 utilities that were intended to increase the credibility of the offer. CLEAResult staff stated that marketing efforts "started too late, and they had a tiny list of people to market to," and timing and lack of urgency compounded with an already small eligibility list. While detailed letters produced higher response rates than postcards or emails, interested households did not often meet the eligibility criteria. The complexity of dual-fuel heat pump technology and installations did not help communication, as some interviewees reported that the value proposition in marketing materials was unclear, especially to those who had recently received weatherization services and a home energy audit. 13 Pilot Implementation and Delivery: Early Stage Energy Trust’s PMC, CLEAResult, helped facilitate, organize, recruit and select contractors, and oversee the management of the Pilot. Contractors played an important role in the Pilot, serving as a key contact point for installation and system setup, operations, and guidance. The following section details the recruitment of and involvement of contractors in the delivery of the Pilot along with equipment selection, the installation process, and system setup. 5.2.1 Contractor Recruitment Energy Trust enrolled contractors for the DFHP Pilot by utilizing a structured Request for Proposal (RFP) process to choose a pre-selected group of trade ally installation contractors from their existing network. This approach, informed by prior experience, was intended to limit the contractor group to facilitate Pilot feedback and insights regarding the DFHP system installations, and to ensure Pilot requirements were met with quality installations. The decision to use a small, exclusive group was viewed as a "win-win" by staff, giving contractors unique access to projects. Participating contractors generally found the enrollment process itself to be "straightforward and easy.” Due to changes in an existing company ownership during the Pilot, program staff approved a new contractor in one region though this contractor was required to develop their own leads, departing from the other contractor requirements. 14 5.2.2 Participant Intake Process Energy Trust’s residential Program Management Contractor (PMC) oversaw a multi-stage participant intake and audit process. The following steps were the main participant intake steps to enroll customers. • • Targeting and Outreach: The program identified potential participants through utility data and direct marketing (letters/emails) based on eligibility criteria. Phone Screening: PMC staff (CLEAResult) conducted initial phone screenings to verify eligibility criteria (e.g., income, gas furnace age, no existing AC) and explained the Pilot offering, associated benefits, and the potential bill impacts to customers. These DFHP candidates were those identified through the CAA participant lists. To ensure existing partners still received the leads from the program to avoid departing from the original agreement. 13 14Page 22 of 47
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 30 Page 22 of 47 • • • • Program Audit: For those passing the initial phone screening, program staff performed in-home audits to verify technical requirements (e.g., ductwork, electrical capacity, weatherization) and confirmed customer interest. Contractor Assignment: Eligible participants were assigned to a pool of seven preselected trade ally contractors for installation. Contractor Assessment and Installation: The assigned contractor conducted their own technical verification, determined DFHP sizing/components, installed and set up the system. Final Verification: Program staff conducted a post-installation verification visit to test that the system was installed and operating correctly. Participants reported high levels of satisfaction with the early phase of the Pilot experience, including the home walkthrough and intake process. Survey questions regarding the Energy Trust home walkthrough covered scheduling convenience, ease of completing forms, politeness of the person conducting the walkthrough, understanding what was happening, knowing the next steps, and effectiveness in answering questions. These topics received overwhelmingly positive responses, and participants frequently gave them the highest satisfaction ratings possible (the percentage of respondents strongly agreeing the process was well done is summarized in Figure 2).The remaining percentage of respondents reported somewhat agreeing to the intake process being well done. Figure 2 DFHP Participant Intake Process Satisfaction (Percentage Strongly Agreeing Process was Well Done) 100% 80% 60% 40% 20% 0% Scheduling Application Forms Staff Politeness Strongly agree Neither agree nor disagree (n=0) Strongly disagree (n=0) Clear Instructions Clear Next Steps Answering Questions Somewhat agree Somewhat disagree (n=0) 5.2.3 Installation Contractors reported that the installation of DFHP systems was generally smooth and efficient, with few issues reported. Contractors described their processes as well-refined, incorporating customer education throughout each stage of engagement, sales, installation, and follow-up to ensure homeowners understand system operation and maintenance. Most DFHP Pilot installations proceeded without difficulty, though occasional adjustments were required for ductwork, electrical capacity, or thermostat setup. During our interviews in thePage 23 of 47
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 30 Page 23 of 47 summer, contractors noted that the recent refrigerant transition to R-454B 15 and the related supply challenges disrupted installation timelines throughout the height of their installation season; these issues do not appear to have impacted the perception of the Pilot from the participant perspective. Participants reported high levels of satisfaction with the Pilot installation process. On survey questions regarding installation, respondents “Strongly Agreed” that they were able to easily schedule the installation at a convenient time, that the installers were polite and respectful, and that installers cleaned up afterward (Figure 3). Figure 3 DFHP Participant Installation Process Satisfaction (Percentage Strongly Agreeing Process was Well Done) Percent Agreeing 100% 80% 60% 40% 20% 0% Scheduling Strongly agree Somewhat disagree Staff Politeness Clean-up Somewhat agree Strongly disagree (n=0) Timing And Prep Answering Questions Neither agree nor disagree In terms of installation challenges, most contractors reported only a few issues with new DFHP systems post installation, which they attributed to heavy investment in customer education throughout the process. This education begins at the sales call and continues through the home visit and installation to verify that participants can operate equipment. Several contractors also perform customer follow-ups post walk-through to ensure customer satisfaction and provide reminders on using their DFHP. Contractors said that customers most commonly reported issues included occasional thermostat calibration problems and defrost mode noise complaints. Equipment defects were rare, with most callbacks attributed to homeowner misunderstanding rather than installation errors. Contractors credited consistent communication and system walk-throughs as key to reducing these incidents. On the occasions when issues arose, they were typically addressed through follow-up visits, remote thermostat adjustments, or manufacturer support. One contractor also mentioned a quality incentive program that rewarded their installers for completing jobs without callbacks. Challenges with installation from the participant perspective involved a small number of respondents who indicated they did not receive sufficient information about operation and performance. Six (out of 24 respondents answering this question) reported not receiving 15 R32 is another refrigerant that is allowed in the newer requirements.Page 24 of 47
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 30 Page 24 of 47 information about setting the DFHP system to maximize energy savings, seven (out of 27 respondents) reported not receiving information about setting the DFHP system to maximize the comfort of their home, and five (out of 27 respondents) reported not receiving information about maintaining the DFHP system so it continues to operate efficiently. The program provided an engagement guide printout that included high level system operation and performance information to all participants which included details that specifically addressed these operational aspects. Pilot Implementation and Delivery: DFHP Systems Details around the DFHP systems that were installed through the Pilot are important to help Energy Trust understand contractor preferences and feedback to inform future offerings while also containing important explanatory attributes that will be used for the second phase of this study which will examine system performance and energy use. 5.3.1 System Size The Pilot had originally targeted the installation of two-ton DFHP systems but ultimately allowed contractors to determine the appropriate capacity based on home characteristics and cooling load calculations. Contractors reported that the most common system size they install is between 2.5 and 3 tons, which they noted aligns with the heating and cooling loads of typical single-family homes in Oregon and those installed through this Pilot. Most contractors mentioned performing load calculations to confirm sizing and ensure eligibility for program quality checks, particularly for systems above 3 tons. Almost half – twenty of the 44 16 – DFHP systems provided in the tracking database with capacity data had capacities greater than the original Pilot cap (two-ton). The tracking database had 51 total sites and while all 51 included total installation cost data only 44 installations included a reported capacity value. 16Page 25 of 47
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 30 Page 25 of 47 Figure 4 HP Capacity for DFHP Systems Participant Count 25 Pilot Capacity Cap: 24k 20 15 10 5 0 16k-22k 23k-25k 26k-33k >34k DFHP Capacity Range 5.3.2 Project Costs Interviewed contractors’ (both participating and non-participating) estimates of the installation costs for a 2-ton DFHP system, in a home that does not need any upgrades, varied widely based on the type of system the contractor preferred, the capacity, single or variable speed motors, and the efficiency of the system. Both participating and non-participating contractors’ estimates for total costs largely aligned with the DFHP Pilot cost caps. The Pilot had original targeted for contractors to install no more than a two‑ton system and keep total installation costs at or below $12,000. Four interviewed contractors reported that basic DFHP systems with minimal installation barriers typically range from $7,000 to $9,000. Six contractors said that the total cost of a typical 2-ton system generally falls between $12,000 and $14,000. On the high end, two contractors noted that final costs for high-efficiency or inverter-driven models can reach $17,000 to $25,000. Contractors in the Mid‑Willamette Valley and Central Oregon felt these parameters were reasonable. However, a Portland‑area contractor said the cap forced them to use equipment that was less advanced than what they typically recommend. Several contractors noted that costs have increased 5–10% in the past year due to manufacturer price adjustments, with tariff impacts expected to raise prices further. On average, contractors estimated DFHP systems are approximately $1,500 more expensive than traditional air conditioning systems. These contractor estimates are similar to the tracking data reporting total installation cost provided by Energy Trust staff. The majority of systems installed fell at or below the $12,000 cost cap, though nine of the 51 DFHP systems provided in the tracking database had total installed costs exceeding the Pilot cap ($12,000). 17 The most 17 The Pilot allowed this flexibility with the $12,000 cap due to these later period installations.Page 26 of 47
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 30 Page 26 of 47 expensive DFHP systems were still less than ten percent above the price cap and eight of the nine systems were installed more recently (after May 2025). This timing is relevant as contractors had noted the recent and substantial price increases for these systems. Figure 5 Total Installed Cost for DFHP Systems (n=51) 40 34 Participant Count 35 30 25 20 15 10 9 8 5 0 $9k-$11k $11k-$12k $12k-$13k DFHP Cost Range 5.3.3 Switchover Temperatures Contractors consistently reported that 35°F is the most common switchover temperature used for DFHP systems, aligning with Energy Trust Pilot guidelines. The switchover temperature Pilot staff initially recommended and which contractors followed is consistent with the findings from a new study conducted for NEEA on DFHP performance. 18 For extended-capacity or variablespeed systems, switchover points are often set lower—typically between 15°F and 20°F, depending on the equipment and the home’s insulation and comfort needs. Some installers adjust settings slightly higher (up to 40–45°F) when homeowners prefer warmer indoor temperatures or when fuel costs make early gas engagement more economical. According to interviewed contractors, while a few customers requested to fine-tune their switchover temperatures, most leave the settings as installed. Contractors typically advise against homeowner adjustments, explaining that improper changes can reduce efficiency and extend warm-up times. Only one DFHP survey respondent indicated making a change to the switchover temperature though the new temperature they provided was 35°F, the same as the Pilot recommended temperature. 19 Dual-Fuel Heat Pump Systems Analysis, Larson Energy Research, September 4, 2025. https://neea.org/wp-content/uploads/2025/09/Dual-Fuel-Heat-Pump-Systems-Analysis.pdf 19 One other respondent indicated they changed the switchover but the temperature they provided, 67, would indicate they confused the switchover with the heating setpoint temperature. 18Page 27 of 47
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 30 Page 27 of 47 5.3.4 Thermostats As a learning outcome from this Pilot, Energy Trust is interested in what systems were installed and are typically recommended or used by trade ally contractors. Further, system information like thermostats will allow greater insights from the second phase of this study where an impact analysis is planned. Contractors all had one or two thermostats they recommend for customers, with Honeywell and Ecobee being the most commonly recommended to customers, as shown in Table 6. According to program tracking data, the thermostats installed for all participants (not just survey respondents) tended to be almost exclusively Ecobee, with two Honeywell and two heat pump system manufacturer-specific. Table 6. Thermostats Recommended by Interviewed Contractors and Installed by Pilot Thermostat Number of Recommendations Installed in Pilot (tracking data) Honeywell (Pro / T6 / 8000) 6 2 Ecobee 5 47 OEM specific 3 2 (Carrier, Lennox) Contractors cited the benefits of Honeywell thermostats, describing their reliability, ease of programming, and compatibility with outdoor sensors for accurate switchover control. Ecobee thermostats were found to be popular among tech-oriented homeowners due to mobile app access, though a couple of contractors noted reliability issues in rural areas where Wi-Fi connectivity is weak. In these locations, Wi-Fi-based thermostats may pull outdoor temperature data from remote weather stations, which can result in inaccurate readings and poor switchover performance. Some manufactures of DFHP systems such as Lennox, Mitsubishi, American Standard, or Daikin require system-specific thermostats. Contractors valued these for their seamless integration and reduced setup errors. In contrast, Nest thermostats were repeatedly flagged as problematic and unable to manage a dual fuel system properly. One contractor stated this should be addressed with the upcoming 4th generation model. Pilot Implementation and Delivery: Late Stage The following section details the late stage of Pilot delivery which mostly involves the Pilot and DFHP system experience from the end user perspective, including the participants’ experience and satisfaction with their DFHP systems and the key benefits and challenges. The bulk of the feedback for this section came from the participant survey, though contractor interview feedback is included where relevant. 5.4.1 DFHP Experience and Satisfaction Consistent with the primary Pilot objective of providing access to cooling to a vulnerable population, households reported that the improved comfort due to the DFHP’s cooling capability was the greatest benefit. A majority (26 of 28 responding to this question) of DFHP participants highlighted their increased home comfort after receiving AC with several (n=4) specifically noting no longer needing to use “inconvenient window AC units.” Other notable benefitsPage 28 of 47
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 30 Page 28 of 47 included improved health due to improved sleep (n=12), improved health due to reduced allergies (n=5), lower utility bills (n=8), energy savings (n=3), and a quieter system than previous heating/cooling equipment (n=4). No DFHP survey respondents reported the addition of a backup heat system as a benefit. All three program contractors agreed that the pilot delivered real benefits to participating households. Contractors noted this is an increasingly important health and safety measure during Oregon’s hotter summers. Satisfaction with the DFHP system was very high, with the majority of respondents (n=23 of 29) being “Very Satisfied” with the system overall. Five respondents were “Somewhat Satisfied” with their DFHP system and a single respondent was “Somewhat Dissatisfied.” This respondent expressed concern around bill increases due to their system, noting, “I am very grateful for the relief in summer. But without question it’s much more expensive to run in winter than the gas furnace, and I worry about electric rates going forward.” Participants were generous with their praise for the benefits provided by the DFHP system and provided the following feedback: • • • • “Summer, especially during heat waves, or very warm overnight temperatures, are now completely stress-free. We never have to worry about being uncomfortably hot at home.” “It's been incredible, especially with guests visiting over the summer and small children in the house. We don't have to worry about their comfort during extreme heat.” “It's changed my life and made this summers heat wave a breeze.” “It has been AMAZING. Definitely the biggest and most noteworthy change in the house overall. With central AC it is much quieter in the house running because the window units are loud. Also, the window units weren't connected to any thermostat and so you had to turn them off and on manually. With the central AC, we can set a temp and it just takes care of itself.” Many program and nonprogram contractors (7 of 13) were strong proponents of the DFHP systems, saying they automatically include a DFHP system in their bids for customers with existing gas furnace systems considering adding cooling or replacing their gas furnace system. A smaller group of contractors (3 of 13) said they wait for customers to express interest in a DFHP before they provide more information or a bid for that option. Contractors reported that, in addition to the general benefits of a heat pump system, DFHPs offer the additional benefit of being able to switch fuels for heating. Contractors promote this feature to customers, citing the likelihood of lower overall heating costs, the ability to warm the home quickly, and, especially for those in rural areas, the ability to use a small generator to keep heating the home when there are power outages. One contractor with a large new construction development said that they install gas furnaces with a DFHP for cooling and heating. The comfort-related benefits conveyed by the DFHP central AC were also seen in how participants compared the comfort of public spaces (like movie theaters or shopping malls) to their home before and after they received the system. Before the DFHP installation, a majority of participants (n=17 of 29) viewed public places as significantly more comfortable than their homes during very hot days while no respondents rated their home as more comfortable. After the installation, 22 respondents stated that their home is now more comfortable than those public places during hot weather. This aligns with staff and contractor input that the biggest benefit perceived by participants was gaining cooling, especially by those who previously lacked any AC or relied on window AC units.Page 29 of 47
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 30 Page 29 of 47 Figure 6: Summer Home Comfort Compared to Public Places Before and After DFHP (summer n=29) Before DFHP After DFHP 0% 20% 40% 60% 80% 100% Winter comfort results for DFHP participants were mixed, though notably limited by a small sample size (n=11 due to a limited pool of participants having experienced a winter heating season following their Pilot participation). While most participants initially felt their home comfort matched that of public spaces before the DFHP, perspectives diverged following the DFHP installation. Post-installation feedback was split nearly equally among those who found their homes less comfortable, equally comfortable, or more comfortable than public buildings. Survey feedback suggests this dissatisfaction stemmed from a preference for the warmer supply air of gas furnaces compared to the cooler output of heat pump systems. Figure 7: Winter Home Comfort Compared to Public Places Before and After DFHP (n=11) Before DFHP After DFHP 0% 20% 40% 60% 80% 100%Page 30 of 47
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 30 Page 30 of 47 Respondents were not curtailing their heating use to save money on their old systems, or that they are doing so the same amount with the new systems. Approximately half of the respondents who experienced a heating season with their DFHP (n=7 of 17) reported never keeping their home colder than they would like to save money in the winter. Of the 10 that did report curtailing their winter use before the pilot, five of 17 curtail heating more than they did before getting the DFHP, while five of 17 curtail heating less than they did before getting the DFHP. Respondents were curtailing their cooling use to save money on their old room AC systems. In the summer, a plurality (n=5 out of 11) reported they never kept their home hotter than comfortable to save energy. Meanwhile, of the 6 that did report curtailing their summer use before the pilot, a small cohort (n=4) reported they no longer have to keep their home warmer to reduce their utility bills since receiving the DFHP. Two respondents reported they still keep their home warmer to reduce their utility bills. 5.4.2 DFHP System Awareness, Use, and Behavior DFHP system awareness was mixed: while eight respondents understood their system's automatic fuel-switching capability, five were unaware of this feature. The program provides this information through the technician and through program materials/handouts. Participants’ lack of awareness may reflect some misunderstanding of the equipment, differences in recall, or just indifference to this system feature. Only one reported updating the switchover temperature, setting it to 35°F (however, 35°F is both the program standard and contractors’ preferred setting). DFHP participants are more likely to favor comfort over energy conservation in summer compared to winter. Participants were asked their DFHP setpoint temperature. More participants kept their winter thermostat at the DOE recommended 68°F, while many preferred summer temperatures below the DOE recommended 78°F. Participants tended to follow energyefficient heating practices in winter but prioritized comfort over efficiency in summer and set thermostats cooler than recommended. 20 These settings may help inform the impacts from the billing analysis taking place next year. This may also mean that DOE guidelines for heating setpoints better align with what people find comfortable than DOE guidelines for cooling setpoints do. 20
Text of CLF-011 Attachment 31.pdf
Extracted from the file · 65 pages · 155,190 characters
Text of CLF-011 Attachment 32.pdf
Extracted from the file · 11 pages · 34,299 characters
As listed on the current system
Question(s) Answered 11 (Connecticut Light and Power Company dba Eversource Energy) Date Filed: 08/27/2026