Skip to main content

A prototype public docket site for the Connecticut Public Utilities Regulatory Authority

Utility Dockets and Filings

Interrogatory responses

Answers to questions 11

ResponseFiled by Connecticut Light and Power Company dba Eversource Energy8 files
Part of docket 26-05-10Open
  • Electric
Application of The Connecticut Light and Power Company d/b/a Eversource Energy to Amend its Rate Schedules

Files8

Text of CLF-011 Attachment 28.pdf

Extracted from the file · 4 pages · 6,964 characters

Text of CLF-011 Attachment 29.pdf

Extracted from the file · 5 pages · 11,434 characters

  1. Page 31 of 47

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 30 Page 31 of 47 Figure 8 DFHP Respondent Temperature Setpoint by Season (summer n = 29, winter n=19) Percent of Responses 70% 60% 65% °F °F Less EE winter temps 50% Less EE summer temps 43% 40% 30% 29% 29% 29% 20% 6% 10% 0% 65-69 degrees 70-74 degrees Winter 75-79 degrees Summer Seven participants reported using supplemental heating, either space heaters or wood stoves prior to participating in the Pilot. Three of the seven reported ceasing use of these after the DFHP. One reported using their supplemental heating “much less” and another reported using theirs ”a little less." Two participants reported using their supplemental heating the same amount as before. As noted in the background section above, DFHP systems deliver heat in a different manner than conventional natural gas furnaces. Heat pump systems deliver air that is cooler than gas furnace forced air systems and require more time to bring homes up to setpoint temperatures. Eight DFHP respondents observed a noticeable difference between their new system and their original gas furnace. Half of the eight who indicated a noticeable change preferred the gas furnace, two preferred the DFHP, and two had no preference. DFHP participants were asked to rate perceptions of their home environment after the DFHP was installed, including factors like home comfort, air quality, and safety (not distinguishing between the summer cooling and winter heating season). Respondents were overwhelmingly in agreement that the DFHP improved the comfort of their homes, with almost three-quarters (71%) strongly agreeing their home comfort improved. Respondents were in less agreement on the improvements to air quality and safety, where the largest cohort (45% for air quality, 54% for safety) did not perceive a change to these aspects attributable to the DFHP system. 21 One hypothesis is that people probably don’t perceive their existing heating systems as unsafe and did not remove their gas appliance, so there isn’t really as clear of a safety benefit for a DFHP system. 21
  2. Page 32 of 47

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 30 Page 32 of 47 Figure 9 Changes to Home After DFHP (n=14) 100% 90% 8% 14% 80% 70% 45% 7% 54% 60% 50% 40% 30% 36% 71% 31% 20% 10% 18% 8% 0% More Comfortable (n=14) Better Air Quality (n=11) Strongly agree Neither agree nor disagree Strongly disagree Improved Safety (n=13) Somewhat agree Somewhat disagree *Question only asked of those with heating season experience, n=14 During enrollment, DFHP participants received information about the new system which included clarification about the expected utility bill impacts: “Your gas bill should go down because your furnace isn’t working as hard. Your electric bill will likely go up since you are now heating your home with electricity some of the time. You also now have cooling in your home, which will increase your summertime electricity bill.” Participants who experienced a heating season with the DFHP noted their perceptions about changes to their bills changing in response to the DFHP. Twelve of 17 heating season participants reported seeing their electric bills increase, while fourteen reported their natural gas bills declined. Eleven of 17 heating season respondents reported much lower gas bills, while six reported much higher electric bills. Respondents who experienced much higher electric bills were more vocal about these changes than those experiencing much lower natural gas bills, so there is a perception about the electric bill increases more than offsetting any reduction in natural gas bills. A deeper exploration of this topic and verification of the impacts will be explored in a second phase impact evaluation for this study.
  3. Page 33 of 47

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 30 Page 33 of 47 Figure 10 DFHP Participant Perception of Utility Bill Changes (n=17) Electric Bills Natural Gas Bills About the same, 2 Much higher, 6 A little lower, 4 A little higher, 6 Much lower, 11 About the same, 1 A little lower, 1 Much lower, 2 *Question only asked of those with heating season experience, n=17 5.4.3 DFHP Drawbacks and Challenges The majority of DFHP survey respondents (n=16 of 29) had no challenges or concerns to date with their DFHP system. In fact, several respondents used the open-ended text entry in the challenges question to note their appreciation of the new system: • • “There aren't any drawbacks with our Dual Fuel Heat Pump system. And no challenges to speak of regarding the system. It is very easy to use and program.” “None, the system has operated perfectly and we are always comfortable.” Though some of the challenges survey respondents reported with their DFHP system were relatively minor, a major concern for participants was the potential for higher electric bills and the cost of operation during the winter. Five survey respondents expressed concerns over their electric bills having "increased" since receiving the DFHP system. 22 Several participants stated that it was "much more expensive to run in winter than the gas furnace" and worried about future electric rate increases. The general concern was that the heat pump was "too expensive to use for heating.” This perception was confirmed by one participant who noted that although their comfort level was significantly higher, their "electric bill was also higher.” Another participant noted that the "electric bill increase even with the help from low-income assistance," although they acknowledged this had been explained to them by the program. While most respondents reported no technical of operational challenges with their DFHP system, several experienced frustrations with the system operation. Four participants noted that A reminder that the original Pilot documentation provided to all participants included language around gas bills decreasing and electric bills increasing because of the DFHP system. One respondent even acknowledged this in a survey verbatim response. 22
  4. Page 34 of 47

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 30 Page 34 of 47 the DFHP system "doesn't heat the house as quickly as the gas furnace" and sometimes takes a "LONG time to get warm. Hours.” One respondent detailed an extensive, months-long problem requiring multiple technician visits. Their DFHP system would work for a short period in cold months, then the air would turn "freezing cold" and pump hard, suggesting an improper setup related to the switchover temperature when the gas furnace should have kicked in. Other specific problems reported included the system performing a "self-shutoff" and one instance where the system "wouldn't cool the house below 78 degrees" when it first ran. One respondent mentioned that their thermostat constantly reported poor "air quality" requiring a window to be opened. A few issues arose related to thermostat settings to maximize the system's benefits. One customer was confused as to the thermostat settings, another was concerned about lack of WiFi capability, and one was confused about what to do during seasonal change when the system switched from cooling to heating, noting, “the technician said to call them in November, and they can come back then.” One issue noted was that the "thermostat was not programmed accordingly—or at least I was not fully informed on how to set the settings for maximum efficiency.” Staff interviews confirmed that one potential challenge is that customers might not receive detailed information beyond the initial phone screening regarding how to operate the system for maximum benefit. Staff also noted that the benefits depend on the customer’s ability to "understand well enough how to use the thermostat to prioritize gas vs electric heat." 23 Although interviewed contractors were proponents of DFHP technology, they noted concerns that aligned with survey respondent feedback. Contractors reported higher electric prices have been a deterrent for many customers, with one contractor, prior to the pilot, describing one DFHP system with a full satisfaction guarantee from the manufacturer that they ultimately had to completely uninstall for a dissatisfied homeowner. Other contractors spoke of issues with the lower heat temperature at the register being an issue, with a few citing visits to customer homes to increase the switchover temperature. One contractor developed a new protocol for disabling the heating function of the heat pump after a senior was quite unhappy with the system because of winter heating costs and yet not feeling warm. The contractor at that point had only had this customer ask for that adjustment, but was concerned that rising electricity prices could have more customers asking for these changes for their heat pump operation. DFHP Market Outlook This section details interviewed contractors and staff (internal and utility) perspectives regarding general sentiment on heat pumps and the DFHP market and their expectations for the near term adoption and interest for this technology. 5.5.1 Detailed Interviewed Contractor Characteristics Contractors, where possible, shared their company background, experience, and level of engagement in the heat pump and DFHP markets. The majority of represented businesses primarily serve the residential market, with only two of the interviewed contractors being from companies with significant business lines in other areas, as shown in Table 7, below. Overall, To be clear, Energy Trust staff does not expect customers to be modifying their switchover temperature in accordance with their other thermostat settings to maximize benefits; we believe the intent with this statement was to maximize system efficiency and not switchover. 23
  5. Page 35 of 47

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 30 Page 35 of 47 contractors reported their businesses have several decades of experience installing heat pumps. In addition, most had also been installing DFHPs for over ten years. The number of DFHPs installed over the last three years varied widely amongst contractors interviewed, with one company reporting 200 installs cumulatively, and another with 12 DFHP installations total over the same time period. DFHPs, on average, represent almost one-fifth (18%) of the contractors residential HVAC business. Table 7. Characteristics of Contractor Firms Interviewed Company Portion of Years Pilot Business Experience Project that is Installing Count Residential HPs HPs as % of Res HVAC Business Central 1 70 60% 2% 12 Mid-Willamette 1 90% 60 50% 10% 45 Portland Metro 5 95% 30 50% 15% 50 Central NP* 95% 20 20 5% 15 Central NP* 10 5% Mid-Willamette NP* 90% 40 20 25% 200 Mid-Willamette NP* 25% 40 30 17% 50 Mid-Willamette NP* 80% 70 20 15% 126 Mid-Willamette NP* 100% 20 50% Portland Metro NP* 85% 10 50% Portland Metro NP* 75% 30 Southern NP* 99% 12 Southern NP* 10% 50 Region 30 30% 60% Company Years Experience Installing DFHPs DFHPs as DFHP % of Res Installs in HVAC last 3 Business years 20 40 4% 10 10% 30 ~3 20% 100 NP = non-participant 5.5.2 Incentives & Rebates Incentives and rebates play a central role in both customer decision-making and contractor sales strategies. Contractors reported that rebate and incentive availability is often one of the first topics discussed with homeowners when determining whether a heat pump system is the right fit for their home. In fact, many contractors point to available tax credits, rebates, and incentives as proof to customers that heat pumps are reliable and beneficial. All contractors interviewed indicated that they actively assist customers in accessing available rebates and credits, often managing the paperwork and submission process directly. Most work with Energy Trust incentives, typically applying them at the project outset to reduce customer out-of-pocket costs. Several also coordinate manufacturer promotions and provide proper paperwork for federal and state tax credits and rebates. One contractor who participated early in the pilot described the initial paperwork for installations to receive the incentive as “a tad terrible” and said pilot payments were delayed by several weeks, far too slow for a business model that normally requires 50% down at scheduling
  6. Page 36 of 47

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 30 Page 36 of 47 and 50% on delivery. Their firm covered the cash‑flow gap temporarily and even secured a line of credit in anticipation of additional installs, but no new participants materialized. Both they and another contractor noted that the payment process eventually improved and became manageable. 5.5.3 Contractor Market Perspective Across interviews, contractors emphasized that continued market growth depends on available incentives, customer education, and electricity costs. When asked about the future of DFHPs in Oregon, contractors expressed cautious optimism, describing a market that seems poised for gradual growth. Several contractors emphasized that DFHP adoption remains largely niche, with most homeowners pursuing the technology if they are interested in electrification, pursuing environmental goals, or interested in new technology, especially if it may also help reduce heating bills. Yet, contractors also noted the higher upfront cost of the DFHP system which they consider the most common barrier, with many customers opting out once they saw price differences compared to standard furnace replacements. Contractors highlighted ongoing technological advances, particularly in cold-climate heat pump models from top manufacturers, expanding the range of homes where DFHPs perform effectively. Several noted increased manufacturing over the last several years may help equipment costs decline, addressing a significant customer barrier. Simultaneously, other contractors raised concerns about the possibility of tariffs depressing the market. Contractors also stated that in many cases, customers simply choose newer versions of the equipment they are replacing, and relatively few seek out a completely new system. 5.5.4 Heat Pump Sentiment The Apex team asked contractors about their experience with and the overall benefits of the broader heat pump market for customers. Contractors indicated that many customers are familiar with the technology and reported that homeowners are most interested in the cost savings, energy efficiency, and air conditioning offered by heat pumps, as shown below in Table 8. Table 8. Contractor Selling Points for Heat Pumps (n=13) Customer Interest in HPs Count Energy/Cost Savings 8 Addition of Cooling 5 Incentives 3 Environmental Benefits 3 Quiet 2 Health Benefits 2 Other 5
  7. Page 37 of 47

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 30 Page 37 of 47 Despite the advantages of heat pumps, contractors agreed that several barriers continue to limit adoption, as shown in Table 9. Winter home comfort was a consistent concern for contractors and their customers. According to contractors, homeowners often complain that the air from a heat pump feels cooler than that from a furnace, describing it as less warm or less satisfying. Contractors explained that this is a normal characteristic of the system—producing air temperatures between 98 and 120 degrees rather than the higher thermal output of a combustion furnace—but that the difference can be unsettling for those accustomed to a “warmer” feel. The potential for periods of extended cold weather coupled with rising electricity prices further heighten these concerns. Table 9. Issues that Discourage Customer Interest in Heat Pumps (n=13) Drawbacks of Heat Pumps Higher Electric Bills Count of Contractors 5 Colder Air for Heating 4 Upfront Cost 3 Complexity of System 2 Other 2 Contractors also cited lingering skepticism about reliability and equipment complexity. In particular, several contractors noted that seniors have been a difficult population to transition to a heat pump successfully. Some homeowners, particularly older ones, worry that heat pumps have “more things to go wrong.” Misunderstandings about efficiency, uncertainty (or even skepticism) around bill savings, and system lifespan are widespread, reinforcing hesitation among potential buyers. One contractor said that they had customers switch over to a heat pump for heating, only to get an $800 electric bill in both January and February one year. That year, the firm paid those heating bills and have since been more careful of customer education practices. In general, all the contractors emphasized that education and expectation-setting are essential to overcoming misinformation on heat pumps and ensuring homeowner satisfaction. 5.5.5 Measure Potential Several utility partners indicated plans or even active independent pilots in place to gain "more control and insight into how things are going and what it means for our system." Utilities hoped to receive some of this information from Energy Trust’s pilot, but at least three interviewed utilities have moved on to create their own pilots for data collection. Utility interest in control over their own DFHP Pilots stemmed from three main reasons: wanting greater control over research priorities and insights, wanting specific data outcome needs, and a desire to test different eligibility criteria. Energy Trust program staff expressed skepticism toward the pilot's long-term viability and becoming a measure. One staff member stated: "I don't expect that this is a measure we promote, at least with a baseline of a furnace with AC," and went on to describe their low expectations: "I don't have high hopes that this is going to pencil out in just short or medium term. I think we'll just forget about it." Staff did not see strong potential in the equipment becoming a measure.
  8. Page 38 of 47

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 30 Page 38 of 47 5.5.6 Contractor Insights on DFHPs by Region Our team interviewed contractors from around Oregon, including three from the Portland Metro Area, four from the Mid‑Willamette Valley, three from Central Oregon, and two from Southern Oregon. Though these markets sit within the same state, they represent notably different climate zones, housing stock, dominant heating fuels, and customer motivations—each of which shapes how DFHPs are positioned and sold. Portland Metro Area In the Portland Metro Area, contractors often frame heat pumps and DFHPs through an environmental and electrification lens. They describe customers, especially those with rooftop solar, as interested in reducing or eliminating fossil fuel use, and they use DFHPs to show a practical path toward that goal while keeping flexibility. The pitch often includes the ability to switch between electricity and gas to take advantage of price fluctuations. For Portland area communities reliant on propane for heating, DFHPs also help take advantage of energy-efficient heating in the warmer winter months and reduce reliance on a more expensive fuel. Contractors in Portland point to the limitations of the area’s older housing stock. Many homes have outdated electrical panels, minimal insulation, or single‑pane windows, and these conditions can complicate DFHP adoption or performance. Where customers proceed, installed costs for a new heat pump were cited as markedly more expensive than other areas, ranging from roughly $13,000 up to $25,000. Mid‑Willamette Valley In the Mid-Willamette Valley, contractors describe DFHPs as well‑matched to the local climate and a solid option for households that want to add cooling. Although DFHPs cost more than installing AC alone, sales staff say customers respond to the resilience and control that come with fuel‑switching and backup heat. This is especially true for the number of households relying on propane in their area. These customers like the ability to rely less on propane day‑to‑day while retaining the furnace for very cold snaps or power outages. Reported install costs in the area vary: one contractor cited completed projects as low as about $7,000, while others—who favor variable‑speed systems—put typical totals closer to $12,000–$14,000. Central Oregon Central Oregon contractors generally see the region’s colder winters as a reason not to recommend DFHPs, except in the case of a home relying on bulk fuels, which was one company’s sales strategy for a couple of years. Two of the three interviewed contractors believe that the technology does not perform as well in their climate zone, where extended subfreezing temperatures are common. In addition, DFHPs are viewed as too expensive for households that simply want to add cooling capacity to an existing home, with one contractor saying that “the equipment cost and installation complexity made [DFHPs] impractical” for most retrofit scenarios. Another mentioned that many of the homes they service have furnaces configured in a downflow arrangement. This setup, he explained, can make DFHP retrofits more complicated and
  9. Page 39 of 47

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 30 Page 39 of 47 expensive because airflow and duct layout need to be carefully redesigned to avoid performance losses. Contractors, when selling DFHPs in this area provide extensive education on the maintenance needs of the system in winter, reminding customers to keep the outdoor unit clear of snow and ice to ensure proper airflow. Southern Oregon Contractors in Southern Oregon are particularly excited about DFHPs. Much of their territory is rural, and customers value the chance to use less propane, and in some pockets, heating oil, without giving up the security of a combustion backup. Pure heat pump solutions are considered risky because winter lows can drop to around −10°F; in those conditions, a DFHP is viewed as the practical choice. One contractor recounted cases of significant winter bill shock— January and February bills around $800—when households relied on the wrong configuration. They also note that DFHPs can work well in manufactured housing and can complement hydronic radiant (hot‑water floor) heating when designed appropriately. Comparison of Energy Trust Heat Pump Pilots Energy Trust is currently administering two distinct heat pump pilots, this DFHP and a No-Cost Pilot. There are some commonalities and some differences between the two offerings, as summarized in Table 10 below. The DFHP has (at least in the earlier phases) more stringent eligibility requirements while the No Cost distinction is that it collaborates with regional and local community-based organizations to help deliver the Pilot. The No Cost Pilot has experienced high participation rates and experienced greater enrollment relative to the DFHP. Table 10 Concurrent Energy Trust Heat Pump Pilots Pilot Element House type Vintage Existing Heating System Type Existing Cooling System Heat Pump System Type DFHP No Cost HP Pilot No AC Single family, Small MF < 5 units, larger affordable MF Any Any electric or bulk fuel (no natural gas) Any Single family Any Furnace <= 5 years old Central ducted HP only Central or Ductless Low-income only (later relaxed) Low-income only Building condition Sufficiently Weatherized Project cost cap $12,000 Sufficiently Weatherized $7,200 for a DHP $17,500 for a HP Income Secondary infrastructure upgrades: Electric Panels and Ductwork Did not require significant upgrades that would result in costs above the maximum incentive Do not require upgrades
  10. Page 40 of 47

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 13, 2026 CLF-011 Attachment 30 Page 40 of 47 Design Inception Limited to approved Energy Trust TA list (n=7) Senior Executive (top-down) Delivery Partners PMC only PMC and CBO Utility Involvement Indirect N/A Trade Ally (contractors) pool Open to Energy Trust TA’s Standard bottom-up

Text of CLF-011 Attachment 31.pdf

Extracted from the file · 65 pages · 155,190 characters

Text of CLF-011 Attachment 32.pdf

Extracted from the file · 11 pages · 34,299 characters

As listed on the current system

Question(s) Answered 11 (Connecticut Light and Power Company dba Eversource Energy) Date Filed: 08/27/2026

This filing on the current system (opens in a new tab)