Interrogatory responses
Answers to questions 132
Files6
NECTA-132_Final.pdf
PDF · 209 KB · 4 pagesText searchable
Download NECTA-132_Final.pdfRead the text of NECTA-132_Final.pdf
NECTA-132 Attachment 1.pdf
PDF · 3.0 MB · 52 pagesText searchable
Download NECTA-132 Attachment 1.pdfRead the text of NECTA-132 Attachment 1.pdf
NECTA-132 Attachment 2.pdf
PDF · 221 KB · 2 pagesText searchable
Download NECTA-132 Attachment 2.pdfRead the text of NECTA-132 Attachment 2.pdf
NECTA-132 Attachment 2.xlsx
Excel · 99 KBText searchable
Download NECTA-132 Attachment 2.xlsxRead the text of NECTA-132 Attachment 2.xlsx
NECTA-132 Attachment 3.pdf
PDF · 1.9 MB · 8 pagesText searchable
Download NECTA-132 Attachment 3.pdfRead the text of NECTA-132 Attachment 3.pdf
NECTA-132 Attachment 4.pdf
PDF · 1.8 MB · 8 pagesText searchable
Download NECTA-132 Attachment 4.pdfRead the text of NECTA-132 Attachment 4.pdf
Page 1 of 52
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued October 14, 2026 NECTA-132 Attachment 1 Page 1 of 52 MATERIAL SPECIFICATION ELECTRIC OPERATIONS ORGANIZATION Wood Distribution Poles Document Number: Issued Date: Revised Date: Revision: SPC-POL-001 05-Oct-16 28-Sep-26 3 Applicability: All ***This Document Supersedes M4701*** Approved by: Signature on File Chad Gandolfi Manager, T&D Standards Engineering Rev No. Date: Description 3 Editorial Update – Revised Appendix A Drawing to correct pole top drill pattern dimensions. Approval date remains the same. 2 Update with DCOI info and removal of Penta. Updated References. 1 Update with latest consolidation changes, Remove Gain 05-Mar-25 Date September 28, 2026 March 7, 2025 November 30, 2016Page 2 of 52
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued October 14, 2026 NECTA-132 Attachment 1 Page 2 of 52 Table of Contents Section Page 1.0 Scope ........................................................................................................................................3 2.0 Reference Codes and Standards ..............................................................................................3 3.0 Ratings ......................................................................................................................................3 4.0 Construction ..............................................................................................................................3 5.0 Additional Material Requirements as Needed ...........................................................................4 6.0 Packaging and Shipping............................................................................................................5 7.0 Test Reports..............................................................................................................................5 Appendix A – Framing of Poles ..........................................................................................................6 SPC-POL-001 Page 2 of 6 Rev 3Page 3 of 52
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued October 14, 2026 NECTA-132 Attachment 1 Page 3 of 52 1.0 Scope This specification covers the requirements for electrical, mechanical, and safety features and characteristics of (wood poles) for use on the Eversource Electrical Distribution System. 2.0 3.0 Reference Codes and Standards ANSI 05.1-2022 Wood Poles – Specifications and Dimensions AWPA U1-24 Use Category System: User Specification for Treated Wood AWPA T1-24 Processing and Treatment Standard AWPA M2-19 Standard for the Inspection of Preservative Treated Products for Industrial Use AWPA M3-16 Standard for the Quality Control of Preservative Treated Products for Industrial Use Ratings Species 3.1.1 Wood species is Southern Yellow Pine or Douglas Fir (fiber stress, 8000 lbs. per square inch, as listed in ANSI 05.01-2022.) 4.0 Construction Trimming 4.1.1 Poles shall be trimmed by machine without materially changing their size or taper. Excessive splintering, indicative of dull machine knives or dry material, and “ringing” of the poles during machining are not permitted. Pole tops and butts shall be neatly sawed perpendicular to the axis of the pole. Slope of tops and butts shall not exceed ½ inch for each 6 inches of pole diameter. Framing Details 4.2.1 Roof-flat 4.2.2 Boring-all holes 11/16 inch ( 1/16 inch) diameter. Face holes and side holes shall be perpendicular to each other and to the axis of the pole refer to Appendix 1, within the following tolerances: .2.1. Face holes, front side: 1/8 inch from centerline, ¼ inch from pole top. .2.2. Face holes, back side: ¼ inch from centerline, ½ inch from pole top. .2.3. Side holes: ½ inch from centerline or pole top, either side. Pole Marking 4.3.1 Poles shall be burn branded on the face with the following items: SPC-POL-001 .1.1. The Eversource logo/quality assurance mark. .1.2. The supplier’s code or trademark. .1.3. The plant location, and the month and year of treatment. Page 3 of 6 Rev 3Page 4 of 52
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued October 14, 2026 NECTA-132 Attachment 1 Page 4 of 52 .1.4. Code letters denoting the pole species and preservative used. .1.5. The class and length of pole. .1.6. The charge number. 4.3.2 Eversource preference is branding, for any other cases pole tags/plates will be accepted as needed, with Eversource approval. Sweep 4.4.1 Maximum sweep allowable in any pole shall be limited to one inch per ten feet of length, measured from the center of the butt and center of the top. Double sweep and reverse sweep shall be limited to ANSI 05.1-2022. Knots 4.5.1 Ring knots-no more than three knots over one inch in diameter in a four inch longitudinal section shall be allowed. Compression Wood 4.6.1 Is prohibited within the outer two inches of the pole surface. Mechanical Damage 4.7.1 Shall be limited to ANSI 05.1-2022 throughout the length of the pole. 5.0 Additional Material Requirements as Needed Preservative Retention and Penetration 5.1.1 Preservatives shall be waterborne chromated copper arsenate (CCA) Type C oxide formulation or Oil-based DCOI. Table 1 – Preservative Retention and Penetration Type AWPA Retention-pcf Assay Penetration CCA Type C Oxide U1-24/ T1-24 0.60 3.5” or 90% of sapwood DCOI U1-24/ T1-24 0.20 0.75” or 85% sapwood SPC-POL-001 Page 4 of 6 Rev 3Page 5 of 52
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued October 14, 2026 NECTA-132 Attachment 1 Page 5 of 52 6.0 Packaging and Shipping Pole Moisture Content 6.1.1 Poles treated with CCA shall be kiln dried before treatment. Kiln drying after treatments is not permitted. All treated poles shall be stacked for a minimum of one calendar month from date of treatment in a manner that will allow free air circulation for efficient drying. All poles shall not have a moisture content (oven dry method, outer two inches) exceeding 45 percent when scheduled for shipment during the period between September 1 and February 28. If the pole moisture content exceeds 45 percent when the poles are scheduled for receipt on Eversource property between September 1 and February 28, the poles must be held by distributor and not shipped until the moisture content limitation is attained. In the period exclusive of September 1 through February 28, all poles shall not have a moisture content exceeding 60 percent. Borings for moisture content determination shall be taken from the approximate midpoint of the pole. Tests to determine moisture content shall be made in accordance with AWPA M2-19. Inspection 6.2.1 The purchaser (or his representative) reserves the right to reject nonconforming poles at any point in the manufacturing process or at the point of delivery or destination. The absence of inspection or quality assurance hammer marks is considered cause for rejection. Inspection and quality control are to be performed in accordance with AWPA M2-19 and awpaM3-16. 7.0 Test Reports The producer’s certified test reports in accordance with AWPA M2-19 shall be provided upon request. SPC-POL-001 Page 5 of 6 Rev 3Page 6 of 52
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued October 14, 2026 NECTA-132 Attachment 1 Page 6 of 52 Appendix A – Framing of Poles SPC-POL-001 Page 6 of 6 Rev 3Page 7 of 52
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued October 14, 2026 NECTA-132 Attachment 1 Page 7 of 52 SPC-ARM-001 MATERIAL SPECIFICATION Revision 1 Distribution Fiberglass Crossarms 1.0 2.0 3.0 4.0 5.0 6.0 Scope .................................................................................................................................. 2 Reference Codes and Standards......................................................................................... 2 Construction ........................................................................................................................ 2 Fabrication ............................................................................................................... 2 3.1 3.2 Filling ....................................................................................................................... 2 3.3 Strength ................................................................................................................... 3 3.4 Treatment ................................................................................................................ 3 3.5 Steel Characteristics ................................................................................................ 3 3.6 Flammability Test ..................................................................................................... 4 Dimensions and Drilling ....................................................................................................... 4 4.1 Drilling Specifications ............................................................................................... 4 4.2 Ground Wire Drilling Specification ............................................................................ 4 Marking and Packing ........................................................................................................... 4 Drilling Requirements .......................................................................................................... 5 Rev # Description Date 1 Eversource Reformat 03/24/2017 0 Original – supersedes M4704. 09/15/2014 Page 1 of 12Page 8 of 52
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued October 14, 2026 NECTA-132 Attachment 1 Page 8 of 52 MATERIAL SPECIFICATION SPC-ARM-001 1.0 Revision 1 Scope The purpose of this standard is to provide specifications and requirements for fiberglass crossarms that are used in distribution line construction by Eversource Electrical Distribution System. 2.0 Reference Codes and Standards The crossarms furnished under this specification shall meet all applicable requirements of the following codes and standards unless otherwise specified herein: ASTM G154-12a ASTM D3801 and ASTM D365 (ANSI/UL 94) ASTM D8019 3.0 Construction 3.1 3.2 Fabrication 3.1.1 Crossarms shall be pultruded fiberglass composite beams with nominal outer dimensions of 3.625 in x 4.625 in to allow attachment of industry standard utility hardware. 3.1.2 Fabrication shall be performed in accordance with the manufacturer’s technical drawings. Material substitutions or deviations from the approved drawings shall not be made without prior written approval. 3.1.3 Drilling or punching of holes shall be done in such a manner as to produce cylindrical holes normal to the plane of the material. Filling 3.2.1 All crossarms shall be made from fiberglass fill with closed cell polyurethane foam sealant. 3.2.2 Impact and UV resistant end caps shall be bonded to the crossarm ends to seal against moisture and contaminants 3.2.3 Fiberglass reinforcement shall be boron-free to prevent corrosive failures. 3.2.4 Crossarms shall be specified in gray or brown color. Page 2 of 12Page 9 of 52
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued October 14, 2026 NECTA-132 Attachment 1 Page 9 of 52 MATERIAL SPECIFICATION SPC-ARM-001 3.3 Revision 1 Strength 3.3.1 Crossarms shall meet the vertical and horizontal loads shown in Table 1 per the latest version of ASTM D8019. Vertical and Horizontal Strength Ratings Fiberglass Crossarm Min Vertical Load per Side 3 5/8’’ x 4 5/8’’ x 5' 7" Tangent Crossarm 4,000 lbs. 3 5/8’’ x 4 5/8’’ x 8’ Tangent Crossarm 3,500 lbs. 3 5/8’’ x 4 5/8’’ x 10’ Tangent Crossarm 3 5/8’’ x 4 5/8’’ x 10’, Fiberglass Heavy Duty Crossarm (BROWN) EMA 3 5/8’’ x 4 5/8’’ x 13’ Tangent Crossarm 2,750 lbs. 5,400 lbs. 2,100 lbs. Fiberglass Crossarm Min Horizontal Load (2 Wires per Arm) 4 5/8’’ x 3 5/8’’ x 8’ Dead-end Crossarm 14,700 lbs. 4 5/8’’ x 3 5/8’’ x 10’ Dead-end Crossarm 12,250 lbs. Tangent Alley Fiberglass Crossarm Min Vertical Load per Side 3 5/8’’ x 4 5/8’’ x 8’, Fiberglass Alley Arm 4,000 lbs. 3 5/8’’ x 4 5/8’’ x 10’, Fiberglass Alley Arm 3,000 lbs. Table 1 – Vertical and Horizontal Strength Ratings 3.4 3.5 Treatment 3.4.1 An abrasion resistant external coating is required to prevent UV degradation of the resin. 3.4.2 A thermally bonded external coating must be applied to the fiberglass to prevent the material from blooming. 3.4.3 A coating must be able to meet a minimum of 10,000 hours exposure in a UV test chamber. Treatment shall be tested according to the latest version of ASTM G154-12a. Steel Characteristics 3.5.1 Galvanizing shall be performed in accordance with the applicable requirements of ASTM A123, A153, and/or F2329. 3.5.2 All bolts, nuts, and threaded rods shall conform to IEEE C135.80. Page 3 of 12Page 10 of 52
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued October 14, 2026 NECTA-132 Attachment 1 Page 10 of 52 MATERIAL SPECIFICATION SPC-ARM-001 Revision 1 A. In addition, all bolts shall conform to SAE J429 Grade 5. 3.6 3.5.3 All eye nuts shall conform to ANSI C135.80. 3.5.4 All mounts, washers, and other steel hardware shall conform to ASTM A36. 3.5.5 All holes in steel shall be added prior to galvanizing Flammability Test 3.6.1 Crossarms shall be tested in compliance with the latest version of ASTM D3801 and ASTM D365 (ANSI/UL 94). 4.0 Dimensions and Drilling 4.1 Drilling Specifications 4.1.1 Dimensions and drilling shall be accordance with the drawings of this specification. All holes shall be 11/16’’ in diameter, unless otherwise noted on drawings, with a +/- 1/32’’ tolerance. Drawings are not to scale. 4.1.2 All drilling holes shall be done prior to treatment. 4.1.3 Drilling tolerances shown in Table 2. Tolerance (+/-) Pin to Pin 1/8’’ From end of arm to first pin 1/4’’ Table 2 – Tolerance in This Table Apply to All Figures in This Standard 4.2 Ground Wire Drilling Specification 4.2.1 3/16” pilot holes shall be drilled on the underside of the crossarm for possible insertion of wire holders to support a ground wire. See drawings for exact spacing per crossarm. 5.0 Marking and Packing 5.1.1 Crossarms shall be identified on the end caps using the manufacture’s name and model. Page 4 of 12
Text of NECTA-132 Attachment 3.pdf
Extracted from the file · 8 pages · 10,921 characters
Text of NECTA-132 Attachment 4.pdf
Extracted from the file · 8 pages · 11,115 characters
As listed on the current system
Question(s) Answered 132 (The Connecticut Light and Power Company) Date Filed: 11/05/2026