Interrogatory responses
Answers to questions 132
Files6
NECTA-132_Final.pdf
PDF · 209 KB · 4 pagesText searchable
Download NECTA-132_Final.pdfRead the text of NECTA-132_Final.pdf
NECTA-132 Attachment 1.pdf
PDF · 3.0 MB · 52 pagesText searchable
Download NECTA-132 Attachment 1.pdfRead the text of NECTA-132 Attachment 1.pdf
NECTA-132 Attachment 2.pdf
PDF · 221 KB · 2 pagesText searchable
Download NECTA-132 Attachment 2.pdfRead the text of NECTA-132 Attachment 2.pdf
NECTA-132 Attachment 2.xlsx
Excel · 99 KBText searchable
Download NECTA-132 Attachment 2.xlsxRead the text of NECTA-132 Attachment 2.xlsx
NECTA-132 Attachment 3.pdf
PDF · 1.9 MB · 8 pagesText searchable
Download NECTA-132 Attachment 3.pdfRead the text of NECTA-132 Attachment 3.pdf
NECTA-132 Attachment 4.pdf
PDF · 1.8 MB · 8 pagesText searchable
Download NECTA-132 Attachment 4.pdfRead the text of NECTA-132 Attachment 4.pdf
Page 11 of 52
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued October 14, 2026 NECTA-132 Attachment 1 Page 11 of 52 MATERIAL SPECIFICATION SPC-ARM-001 Revision 1 5.1.2 Reasonable care shall be taken to avoid damage to the crossarms during handling and transportation. 5.1.3 Crossarms shall be stacked and packaged in quantities capable of forklift handling. 6.0 Drilling Requirements Figure Description 1 3 5/8’’ x 4 5/8’’ x 5' 7", Fiberglass Tangent Crossarm 2 3 5/8’’ x 4 5/8’’ x 8’, Fiberglass Tangent Crossarm 3 3 5/8’’ x 4 5/8’’ x 10’, Fiberglass Tangent Crossarm 4 3 5/8’’ x 4 5/8’’ x 10’, Fiberglass Tangent Crossarm (BROWN) NH 5 6 3 5/8’’ x 4 5/8’’ x 13’, Fiberglass Tangent 4 5/8’’ x 3 5/8’’ x 8’, Fiberglass Dead-end Crossarm 7 4 5/8’’ x 3 5/8’’ x 10’, Fiberglass Dead-end Crossarm 8 4 5/8’’ x 3 5/8’’ x 10’, Fiberglass Dead-end Crossarm (BROWN) NH 9 3 5/8’’ x 4 5/8’’ x 10’, Fiberglass Heavy Duty Crossarm (BROWN) EMA 10 3 5/8’’ x 4 5/8’’ x 21’, Bare Fiberglass Arm 11 12 3 5/8’’ x 4 5/8’’ x 8’, Fiberglass Alley Arm 3 5/8’’ x 4 5/8’’ x 10’, Fiberglass Alley Arm Page 5 of 12Page 12 of 52
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued October 14, 2026 NECTA-132 Attachment 1 Page 12 of 52 SPC-ARM-001 MATERIAL SPECIFICATION Revision 1 Figure 1 – 3 5/8’’ x 4 5/8’’ x 5' 7", Fiberglass Tangent Crossarm Page 6 of 12Page 13 of 52
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued October 14, 2026 NECTA-132 Attachment 1 Page 13 of 52 SPC-ARM-001 MATERIAL SPECIFICATION Revision 1 Figure 2 – 3 5/8’’ x 4 5/8’’ x 8’, Fiberglass Tangent Crossarm Figure 3 – 3 5/8’’ x 4 5/8’’ x 10’, Fiberglass Tangent Crossarm Page 7 of 12Page 14 of 52
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued October 14, 2026 NECTA-132 Attachment 1 Page 14 of 52 SPC-ARM-001 MATERIAL SPECIFICATION Revision 1 Figure 4 – 3 5/8’’ x 4 5/8’’ x 10’, Fiberglass Tangent Crossarm (BROWN) NH ONLY Figure 5 – 3 5/8’’ x 4 5/8’’ x 13’, Fiberglass Tangent Crossarm Figure 6 – 3 5/8’’ x 4 5/8’’ x 8’, Fiberglass Dead-end Crossarm Page 8 of 12Page 15 of 52
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued October 14, 2026 NECTA-132 Attachment 1 Page 15 of 52 SPC-ARM-001 MATERIAL SPECIFICATION Revision 1 Figure 7 – 3 5/8’’ x 4 5/8’’ x 10’, Fiberglass Dead-end Crossarm Figure 8 – 3 5/8’’ x 4 5/8’’ x 10’, Fiberglass Dead-end Crossarm (BROWN) NH ONLY Page 9 of 12Page 16 of 52
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued October 14, 2026 NECTA-132 Attachment 1 Page 16 of 52 SPC-ARM-001 MATERIAL SPECIFICATION Revision 1 Figure 9 – 3 5/8’’ x 4 5/8’’ x 10’, Fiberglass Heavy Duty Crossarm (BROWN) Figure 10 – 3 5/8’’ x 4 5/8’’ x 21’’, Bare Fiberglass Crossarm Page 10 of 12Page 17 of 52
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued October 14, 2026 NECTA-132 Attachment 1 Page 17 of 52 SPC-ARM-001 MATERIAL SPECIFICATION Revision 1 Figure 11 – 3 5/8’’ x 4 5/8’’ x 8’, Fiberglass Alley Arm Page 11 of 12Page 18 of 52
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued October 14, 2026 NECTA-132 Attachment 1 Page 18 of 52 SPC-ARM-001 MATERIAL SPECIFICATION Revision 1 Figure 12– 3 5/8’’ x 4 5/8’’ x 10’, Fiberglass Alley Arm Page 12 of 12Page 19 of 52
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued October 14, 2026 NECTA-132 Attachment 1 Page 19 of 52 SPC-ARM-002 MATERIAL SPECIFICATION Revision 1 Distribution Wood Crossarms 1.0 2.0 3.0 4.0 Scope .................................................................................................................................. 2 Reference Codes and Standards......................................................................................... 2 Specifications ...................................................................................................................... 2 Species .................................................................................................................... 2 Treatment and Preservation ..................................................................................... 2 Dimensions and Drilling ........................................................................................... 2 Tolerances ............................................................................................................... 3 Drilling Requirements .......................................................................................................... 3 Rev # Description Date 1 Eversource Reformat 03/3/2017 0 Original – supersedes M4700. 02/25/2013 Approval CWPPage 20 of 52
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued October 14, 2026 NECTA-132 Attachment 1 Page 20 of 52 MATERIAL SPECIFICATION SPC-ARM-002 1.0 Revision 1 Scope This specification covers the requirements for wood crossarms used in the distribution line construction by Eversource Electrical Distribution Companies. 2.0 Reference Codes and Standards The distribution wood crossarms furnished under this specification shall meet all applicable requirements of the following codes and standards unless otherwise specified herein: 3.0 • ANSI O5.3 and AWPA M5-98 • AWPA C1-98 and C25-95 Specifications Species 3.1.1 All crossarms shall be made from Douglas Fir. Treatment and Preservation 3.2.1 Preservatives shall be pentachlorophenol. 3.2.2 Treatment and retention shall be in compliance with the latest revision of AWPA Standard C25. 3.2.3 The preservative shall penetrate all the sapwood. It shall penetrate heartwood and sapwood longitudinally from the pin holes, bolt holes and ends, a minimum of 3 inches. 3.2.4 The treating methods shall not injure the wood. After treatment, crossarms shall be free of tarry, greasy or sticky material, and of oil exudation and pentachlorophenol, and shall remain so. Dimensions and Drilling 3.3.1 Dimensions and drilling shall be in accordance with the drawings of this specification. All holes (including pinholes) shall be 11/16” in diameter, unless otherwise noted on drawings, with a +/- 1/32” tolerance. Drawings are not to scale. 3.3.2 All drilling shall be done prior to treatment.
Text of NECTA-132 Attachment 3.pdf
Extracted from the file · 8 pages · 10,921 characters
Text of NECTA-132 Attachment 4.pdf
Extracted from the file · 8 pages · 11,115 characters
As listed on the current system
Question(s) Answered 132 (The Connecticut Light and Power Company) Date Filed: 11/05/2026