Interrogatory responses
Answers to questions 132
Files6
NECTA-132_Final.pdf
PDF · 209 KB · 4 pagesText searchable
Download NECTA-132_Final.pdfRead the text of NECTA-132_Final.pdf
NECTA-132 Attachment 1.pdf
PDF · 3.0 MB · 52 pagesText searchable
Download NECTA-132 Attachment 1.pdfRead the text of NECTA-132 Attachment 1.pdf
NECTA-132 Attachment 2.pdf
PDF · 221 KB · 2 pagesText searchable
Download NECTA-132 Attachment 2.pdfRead the text of NECTA-132 Attachment 2.pdf
NECTA-132 Attachment 2.xlsx
Excel · 99 KBText searchable
Download NECTA-132 Attachment 2.xlsxRead the text of NECTA-132 Attachment 2.xlsx
NECTA-132 Attachment 3.pdf
PDF · 1.9 MB · 8 pagesText searchable
Download NECTA-132 Attachment 3.pdfRead the text of NECTA-132 Attachment 3.pdf
NECTA-132 Attachment 4.pdf
PDF · 1.8 MB · 8 pagesText searchable
Download NECTA-132 Attachment 4.pdfRead the text of NECTA-132 Attachment 4.pdf
The searchable text of a spreadsheet keeps the sheet names, column headings and text cells. Download the file for the figures.
Part 1
[Sheet: NECTA-132, Attachment 2] Work Order 80408037 Details - Compatible Unit and Estimate Reconstruction KEY LEGEND Add = Addition (also, the Power Plan As Built Add relates to those costs that are utlimately part of FERC Account 101) COR = Cost of Removal (also, the Power Plan As Built COR relates to those costs that are ultimately part of FERC Account 108). OCR = Original Cost Retirement (also, in cases where we have a broad group procedure, as described in OCC-793, the retirement value is based on the curve vintage and book cost of that vintage to be retired). Source > Work Order Compatible Unit Detail pulled from Work Management System (Maximo) - columns (a) through (l) | Plant Accounting Notes (system automated): (a) | (c) | (d) | (e) | (f) | (g) | (h) | (i) | (j) | (k) | (l) CU Name | Record Type | Description | Item | Quantity | Site Hours | Hourly Rate | Unit Cost | Line Cost | FERC Utility Acct | RU (Asset Code) | PowerPlan As Built | See on estimate (2) LE-XARM-TYP1 | LBR | Labor, Crossarm, Type 1 | Add Labor - 364 | a LE-PIN | LBR | Labor, Pin, Insulator or Stud | Add Labor - 364 | a LE-BOLT-OH | LBR | Labor, Bolt, Overhead, All Types | COR labor - 364 | g LE-PIN-PT | LBR | Labor, Pin, Pole Top | COR labor - 364 | g LE-XARM-TYP1 | LBR | Labor, Crossarm, Type 1 | COR labor - 364 | g LE-PIN | LBR | Labor, Pin, Insulator or Stud | COR labor - 364 | g LE-INS-PRI-TYP1 | LBR | Labor, Insulator, Primary, Type 1 | COR labor - 365 | h LE-BOLT-OH | LBR | Labor, Bolt, Overhead, All Types | Add Labor - 364 | a LE-INS-PRI-TYP1 | LBR | Labor, Insulator, Primary, Type 1 | Add Labor - 365 | b LE-PIN-PT | LBR | Labor, Pin, Pole Top | Add Labor - 364 | a INPVISEPOLY35KV1IN | MTL | INSULATOR, PIN, VISE TOP, 35 KV, 1 IN, POLYMER, FOR COVERED OR BARE WIRE | Add material - 365 | d WALOCKDCSGS5/8IN | MTL | WASHER,SPRING, COIL, 5/8 IN, GALV | Add material - 364 | c INPVISEPOLY35KV1IN | MTL | INSULATOR, PIN, VISE TOP, 35 KV, 1 IN, POLYMER, FOR COVERED OR BARE WIRE | OCR quantity | f PNPT24IN | MTL | WASHER,SQUARE, CURVED, 3 IN X 3 IN X 1/4 IN SQ, GALV, FOR 5/8 IN OR 3/4 IN BOLT | Add material - 364 | c PNPT24IN | MTL | BOLT,MACHINE, 5/8 IN, 14 IN LG, STEEL, GALV, W/ SQUARE NUT | Add material - 364 | c PNPT24IN | MTL | PIN,INSULATOR, POLE TOP, 24 IN LG, GALV STEEL, 1 IN THREADED | Add material - 364 | c XASTANFG8FTW/HDWR | MTL | CROSSARM, TANGENT, 3-5/8 X 4-5/8 IN, 8 FT LG, W/ CENTER MOUNT BRACKET AND HARDWARE, FIBERGLASS, 49 EA/PALLET | OCR quantity | e XASTANFG8FTW/HDWR | MTL | WASHER,SQUARE, CURVED, 3 IN X 3 IN X 1/4 IN SQ, GALV, FOR 5/8 IN OR 3/4 IN BOLT | Add material - 364 | c XASTANFG8FTW/HDWR | MTL | BOLT,MACHINE, 5/8 IN, 14 IN LG, STEEL, GALV, W/ SQUARE NUT | Add material - 364 | c BLOMCHGS5/8X14INSQW/WSHR | MTL | BOLT,MACHINE, 5/8 IN, 14 IN LG, STEEL, GALV, W/ SQUARE NUT | Add material - 364 | c BLOMCHGS5/8X14INSQW/WSHR | MTL | WASHER,FLAT, SQUARE, 2-1/4 IN X 2-1/4 IN, 3/16 IN THK, GALV, FOR 5/8 IN & 3/4 IN BOLTS | Add material - 364 | c XASTANFG8FTW/HDWR | MTL | CROSSARM, TANGENT, 3-5/8 X 4-5/8 IN, 8 FT LG, W/ CENTER MOUNT BRACKET AND HARDWARE, FIBERGLASS, 49 EA/PALLET | Add material - 364 | c PNINS8INW/7-3/4SHK | MTL | PIN,INSULATOR, CROSSARM, 5/8 X 7-3/4 IN SHANK, 8 IN, GALV STEEL, 1 IN THREADED, JUMBO | Add material - 364 | c WASQFLATGS3.5X3.5IN | MTL | WASHER,FLAT, SQUARE, 3.5 IN X 3.5 IN X 0.375 IN SQ, STEEL, GALV, FOR 5/8 IN BOLT | Add material - 364 | c WASQCURVED3X3X1/4 | MTL | WASHER,SQUARE, CURVED, 3 IN X 3 IN X 1/4 IN SQ, GALV, FOR 5/8 IN OR 3/4 IN BOLT | Add material - 364 | c (2) Work Order Powerplan Estimate ADDITIONS (FERC Account 101) sum of a b sum of c d e f COST OF REMOVAL (FERC Account 108) sum of g h
Text of NECTA-132 Attachment 3.pdf
Extracted from the file · 8 pages · 10,921 characters
Text of NECTA-132 Attachment 4.pdf
Extracted from the file · 8 pages · 11,115 characters
As listed on the current system
Question(s) Answered 132 (The Connecticut Light and Power Company) Date Filed: 11/05/2026