Skip to main content

A prototype public docket site for the Connecticut Public Utilities Regulatory Authority

Utility Dockets and Filings

Interrogatory responses

Answers to questions 30, 31, 34, 36

Files20

Text of NECTA-031 Attachment 2 REDACTED.pdf

Extracted from the file · 58 pages, 8 without text · 99,401 characters

Text of NECTA-031_Final.pdf

Extracted from the file · 1 page · 691 characters

Text of NECTA-034_Final.pdf

Extracted from the file · 2 pages · 3,527 characters

Text of NECTA-034 Attachment 1.pdf

Extracted from the file · 1 page · 1,849 characters

Text of NECTA-034 Attachment 1.xlsx

Sheet names, column headings and text cells; numbers left out

Text of NECTA-034 Attachment 2.pdf

Extracted from the file · 2 pages · 2,868 characters

Text of NECTA-034 Attachment 3.pdf

Extracted from the file · 2 pages · 3,478 characters

Text of NECTA-034 Attachment 4.pdf

Extracted from the file · 2 pages · 2,891 characters

Text of NECTA-034 Attachment 5.pdf

Extracted from the file · 2 pages · 3,093 characters

  1. Page 1

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 09, 2026 NECTA-034 Attachment 6 Page 1 of 2 107 Selden Street, Berlin, CT 06037 P.O. Box 270, Hartford, CT 06141-0270 Christopher R. Bernard Manager-Regulatory Policy & Strategy, CT [phone removed] [email removed] March 31, 2022 Jeffrey R. Gaudiosi Executive Secretary Public Utilities Regulatory Authority 10 Franklin Square New Britain, CT 06051 Re: Docket No. 11-03-07, PURA Investigation Into The Appointment Of A Third Party Statewide Utility Telephone Pole Administrator For The State Of Connecticut – (Order No. 10 Compliance) Dear Mr. Gaudiosi: The Connecticut Light and Power Company dba Eversource Energy (the “Company”) herewith files the annual SPA costs on its program to serve as the Single Pole Administrator (“SPA”) within its service territory in compliance with Order No. 10 of the Public Utilities Regulatory Authority’s (“Authority’s”) October 8, 2014 Decision in the above-referenced docket. Order No. 10 states1: No later than March 31, 2015, and annually thereafter, the SPAs shall report the annual items outlined in Section II.C.4 Reporting Requirements. Section II.C.4 Reporting Requirements in this Decision identify the following: 9. Annual SPA costs (tables below) 10. Annual SPA costs proposed to be recovered in a future rate case With regards to Reporting Requirement 9, the Company’s annual SPA costs in 2021 were $3,056,523.00 as shown in the following tables: Annual SPA Costs O&M Contractor Labor- Survey, Design, and SPA Services Software Internal Labor 1,062,688 Overhead Costs 0 Reimbursables 0 Survey and Application Fees Collected Other (1,355,643) Total O&M 106,811 214,200 184,759 807
  2. Page 2

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 09, 2026 NECTA-034 Attachment 6 Page 2 of 2 Mr. Jeffrey R. Gaudiosi Page 2 March 31, 2022 Annual SPA Costs Contractor Labor-Survey, Design, and SPA Services Software Internal Labor Overhead Costs Capital 2,789,174 Reimbursables (1,734) Survey Fees Collected 0 Other Total Capital Total Annual SPA Costs 6,443 2,949,712 3,056,523 0 133,424 22,405 The costs provided are operational costs to the Company in its role strictly as the SPA and do not include construction or other associated costs. Regarding Reporting Requirement 10, the Company plans to submit costs associated with the implementation of the Alden Systems software along with the costs required to process thirdparty applications, administer pole transfers, and perform the role of the SPA in its next base distribution rate case, where the Authority can determine if the recovery of these costs will be borne by the cost causers or be included in the Company’s base distribution rates. Please contact Mr. Richard Comeau at [phone removed], if you have any questions concerning this filing. Very truly yours, Christopher R. Bernard Manager – Regulatory Policy & Strategy, CT As Agent for CL&P dba Eversource Energy cc: Service List Attachment

Text of NECTA-034 Attachment 7.pdf

Extracted from the file · 2 pages · 3,023 characters

Text of NECTA-034 Attachment 8.pdf

Extracted from the file · 2 pages · 3,032 characters

Text of NECTA-034 Attachment 9.pdf

Extracted from the file · 2 pages · 3,017 characters

Text of NECTA-034 Attachment 10.pdf

Extracted from the file · 2 pages · 3,022 characters

Text of NECTA-036_Final.pdf

Extracted from the file · 1 page · 773 characters

Text of NECTA-036 Attachment 1.pdf

Extracted from the file · 1 page · 2,417 characters

Text of NECTA-036 Attachment 1.xlsx

Sheet names, column headings and text cells; numbers left out

As listed on the current system

Question(s) Answered 30, 31, 34, 36 (The Connecticut Light and Power Company) Date Filed: 09/24/2026

This filing on the current system (opens in a new tab)