Interrogatory responses
Answers to questions 507, 508, 509, 510, 511, 512, 517, 518
Files53
OCC-507_Final.pdf
PDF · 195 KB · 6 pagesText searchable
Download OCC-507_Final.pdfRead the text of OCC-507_Final.pdf
OCC-508_Final.pdf
PDF · 81 KB · 1 pageText searchable
Download OCC-508_Final.pdfRead the text of OCC-508_Final.pdf
OCC-509_Final.pdf
PDF · 86 KB · 1 pageText searchable
Download OCC-509_Final.pdfRead the text of OCC-509_Final.pdf
OCC-510_Final.pdf
PDF · 190 KB · 3 pagesText searchable
Download OCC-510_Final.pdfRead the text of OCC-510_Final.pdf
OCC-511_Final.pdf
PDF · 215 KB · 8 pagesText searchable
Download OCC-511_Final.pdfRead the text of OCC-511_Final.pdf
OCC-512_Final.pdf
PDF · 82 KB · 1 pageText searchable
Download OCC-512_Final.pdfRead the text of OCC-512_Final.pdf
OCC-517_Final.pdf
PDF · 131 KB · 1 pageText searchable
Download OCC-517_Final.pdfRead the text of OCC-517_Final.pdf
OCC-518_Final.pdf
PDF · 81 KB · 1 pageText searchable
Download OCC-518_Final.pdfRead the text of OCC-518_Final.pdf
OCC-512 Attachment 3 REDACTED.pdf
PDF · 5.2 MB · 33 pagesText searchable
Download OCC-512 Attachment 3 REDACTED.pdfRead the text of OCC-512 Attachment 3 REDACTED.pdf
OCC-512 Attachment 2 REDACTED.pdf
PDF · 6.8 MB · 33 pagesText searchable
Download OCC-512 Attachment 2 REDACTED.pdfRead the text of OCC-512 Attachment 2 REDACTED.pdf
OCC-512 Attachment 1.pdf
PDF · 23 MB · 626 pagesText searchable
Download OCC-512 Attachment 1.pdfRead the text of OCC-512 Attachment 1.pdf
OCC-507 Attachment 42.pdf
PDF · 1.7 MB · 3 pagesText searchable
Download OCC-507 Attachment 42.pdfRead the text of OCC-507 Attachment 42.pdf
OCC-507 Attachment 41.pdf
PDF · 1.8 MB · 9 pagesText searchable
Download OCC-507 Attachment 41.pdfRead the text of OCC-507 Attachment 41.pdf
OCC-507 Attachment 40.pdf
PDF · 2.2 MB · 5 pagesText searchable
Download OCC-507 Attachment 40.pdfRead the text of OCC-507 Attachment 40.pdf
OCC-507 Attachment 38.pdf
PDF · 4.6 MB · 19 pagesText searchable
Download OCC-507 Attachment 38.pdfRead the text of OCC-507 Attachment 38.pdf
OCC-507 Attachment 37.pdf
PDF · 2.9 MB · 49 pagesText searchable
Download OCC-507 Attachment 37.pdfRead the text of OCC-507 Attachment 37.pdf
OCC-507 Attachment 36.pdf
PDF · 2.9 MB · 59 pagesText searchable
Download OCC-507 Attachment 36.pdfRead the text of OCC-507 Attachment 36.pdf
OCC-507 Attachment 35.pdf
PDF · 4.3 MB · 38 pagesText searchable
Download OCC-507 Attachment 35.pdfRead the text of OCC-507 Attachment 35.pdf
OCC-507 Attachment 34.pdf
PDF · 2.1 MB · 5 pagesText searchable
Download OCC-507 Attachment 34.pdfRead the text of OCC-507 Attachment 34.pdf
OCC-507 Attachment 33.pdf
PDF · 2.9 MB · 13 pagesText searchable
Download OCC-507 Attachment 33.pdfRead the text of OCC-507 Attachment 33.pdf
OCC-507 Attachment 32.pdf
PDF · 1.6 MB · 5 pagesText searchable
Download OCC-507 Attachment 32.pdfRead the text of OCC-507 Attachment 32.pdf
OCC-507 Attachment 29.pdf
PDF · 1.8 MB · 8 pagesText searchable
Download OCC-507 Attachment 29.pdfRead the text of OCC-507 Attachment 29.pdf
OCC-507 Attachment 28.pdf
PDF · 2.5 MB · 18 pagesText searchable
Download OCC-507 Attachment 28.pdfRead the text of OCC-507 Attachment 28.pdf
OCC-507 Attachment 27.pdf
PDF · 3.0 MB · 35 pagesText searchable
Download OCC-507 Attachment 27.pdfRead the text of OCC-507 Attachment 27.pdf
OCC-507 Attachment 26.pdf
PDF · 5.0 MB · 19 pagesText searchable
Download OCC-507 Attachment 26.pdfRead the text of OCC-507 Attachment 26.pdf
OCC-507 Attachment 25.pdf
PDF · 2.0 MB · 12 pagesText searchable
Download OCC-507 Attachment 25.pdfRead the text of OCC-507 Attachment 25.pdf
OCC-507 Attachment 24.pdf
PDF · 1.5 MB · 2 pagesText searchable
Download OCC-507 Attachment 24.pdfRead the text of OCC-507 Attachment 24.pdf
OCC-507 Attachment 23.pdf
PDF · 21 MB · 268 pagesText searchable
Download OCC-507 Attachment 23.pdfRead the text of OCC-507 Attachment 23.pdf
OCC-507 Attachment 22.pdf
PDF · 25 MB · 178 pagesText searchable
Download OCC-507 Attachment 22.pdfRead the text of OCC-507 Attachment 22.pdf
OCC-507 Attachment 21.pdf
PDF · 38 MB · 296 pagesText searchable
Download OCC-507 Attachment 21.pdfRead the text of OCC-507 Attachment 21.pdf
OCC-507 Attachment 20.pdf
PDF · 22 MB · 167 pagesText searchable
Download OCC-507 Attachment 20.pdfRead the text of OCC-507 Attachment 20.pdf
OCC-507 Attachment 19.pdf
PDF · 9.1 MB · 137 pagesText searchable
Download OCC-507 Attachment 19.pdfRead the text of OCC-507 Attachment 19.pdf
OCC-507 Attachment 18.pdf
PDF · 17 MB · 247 pagesText searchable
Download OCC-507 Attachment 18.pdfRead the text of OCC-507 Attachment 18.pdf
OCC-507 Attachment 17.pdf
PDF · 1.4 MB · 2 pagesText searchable
Download OCC-507 Attachment 17.pdfRead the text of OCC-507 Attachment 17.pdf
OCC-507 Attachment 16.pdf
PDF · 1.4 MB · 2 pagesText searchable
Download OCC-507 Attachment 16.pdfRead the text of OCC-507 Attachment 16.pdf
OCC-507 Attachment 15.pdf
PDF · 32 MB · 202 pagesText searchable
Download OCC-507 Attachment 15.pdfRead the text of OCC-507 Attachment 15.pdf
OCC-507 Attachment 14.pdf
PDF · 2.6 MB · 6 pagesText searchable
Download OCC-507 Attachment 14.pdfRead the text of OCC-507 Attachment 14.pdf
OCC-507 Attachment 13.pdf
PDF · 4.8 MB · 19 pagesText searchable
Download OCC-507 Attachment 13.pdfRead the text of OCC-507 Attachment 13.pdf
OCC-507 Attachment 12.pdf
PDF · 4.6 MB · 19 pagesText searchable
Download OCC-507 Attachment 12.pdfRead the text of OCC-507 Attachment 12.pdf
OCC-507 Attachment 11.pdf
PDF · 4.9 MB · 7 pagesText searchable
Download OCC-507 Attachment 11.pdfRead the text of OCC-507 Attachment 11.pdf
OCC-507 Attachment 8.pdf
PDF · 1.4 MB · 2 pagesText searchable
Download OCC-507 Attachment 8.pdfRead the text of OCC-507 Attachment 8.pdf
OCC-507 Attachment 4.pdf
PDF · 2.6 MB · 6 pagesText searchable
Download OCC-507 Attachment 4.pdfRead the text of OCC-507 Attachment 4.pdf
OCC-507 Attachment 2.pdf
PDF · 2.2 MB · 8 pagesText searchable
Download OCC-507 Attachment 2.pdfRead the text of OCC-507 Attachment 2.pdf
OCC-507 Attachment 1.pdf
PDF · 3.5 MB · 32 pagesText searchable
Download OCC-507 Attachment 1.pdfRead the text of OCC-507 Attachment 1.pdf
OCC-507 Attachment 39.pdf
PDF · 1.5 MB · 22 pagesText searchable
Download OCC-507 Attachment 39.pdfRead the text of OCC-507 Attachment 39.pdf
OCC-507 Attachment 31.pdf
PDF · 1.8 MB · 8 pagesText searchable
Download OCC-507 Attachment 31.pdfRead the text of OCC-507 Attachment 31.pdf
OCC-507 Attachment 30.pdf
PDF · 1.9 MB · 5 pagesText searchable
Download OCC-507 Attachment 30.pdfRead the text of OCC-507 Attachment 30.pdf
OCC-507 Attachment 10.pdf
PDF · 1.6 MB · 3 pagesText searchable
Download OCC-507 Attachment 10.pdfRead the text of OCC-507 Attachment 10.pdf
OCC-507 Attachment 9.pdf
PDF · 6.2 MB · 10 pagesText searchable
Download OCC-507 Attachment 9.pdfRead the text of OCC-507 Attachment 9.pdf
OCC-507 Attachment 7.pdf
PDF · 1.5 MB · 3 pagesText searchable
Download OCC-507 Attachment 7.pdfRead the text of OCC-507 Attachment 7.pdf
OCC-507 Attachment 6.pdf
PDF · 1.5 MB · 4 pagesText searchable
Download OCC-507 Attachment 6.pdfRead the text of OCC-507 Attachment 6.pdf
OCC-507 Attachment 5.pdf
PDF · 1.5 MB · 4 pagesText searchable
Download OCC-507 Attachment 5.pdfRead the text of OCC-507 Attachment 5.pdf
OCC-507 Attachment 3.pdf
PDF · 5.4 MB · 65 pagesText searchable
Download OCC-507 Attachment 3.pdfRead the text of OCC-507 Attachment 3.pdf
Text of OCC-510_Final.pdf
Extracted from the file · 3 pages · 6,553 characters
Text of OCC-511_Final.pdf
Extracted from the file · 8 pages · 17,894 characters
Text of OCC-512_Final.pdf
Extracted from the file · 1 page · 992 characters
Text of OCC-517_Final.pdf
Extracted from the file · 1 page · 826 characters
Text of OCC-518_Final.pdf
Extracted from the file · 1 page · 601 characters
Text of OCC-512 Attachment 3 REDACTED.pdf
Extracted from the file · 33 pages · 5,436 characters
Text of OCC-512 Attachment 2 REDACTED.pdf
Extracted from the file · 33 pages · 5,436 characters
Text of OCC-512 Attachment 1.pdf
Extracted from the file · 626 pages · 635,148 characters
Text of OCC-507 Attachment 42.pdf
Extracted from the file · 3 pages · 10,259 characters
Text of OCC-507 Attachment 41.pdf
Extracted from the file · 9 pages · 3,276 characters
Text of OCC-507 Attachment 40.pdf
Extracted from the file · 5 pages · 8,775 characters
Text of OCC-507 Attachment 38.pdf
Extracted from the file · 19 pages · 96,311 characters
Text of OCC-507 Attachment 37.pdf
Extracted from the file · 49 pages · 120,692 characters
Text of OCC-507 Attachment 36.pdf
Extracted from the file · 59 pages · 136,630 characters
Text of OCC-507 Attachment 35.pdf
Extracted from the file · 38 pages · 102,807 characters
Text of OCC-507 Attachment 34.pdf
Extracted from the file · 5 pages · 1,210 characters
Text of OCC-507 Attachment 33.pdf
Extracted from the file · 13 pages · 52,489 characters
Text of OCC-507 Attachment 32.pdf
Extracted from the file · 5 pages · 14,030 characters
Text of OCC-507 Attachment 29.pdf
Extracted from the file · 8 pages · 37,747 characters
Text of OCC-507 Attachment 28.pdf
Extracted from the file · 18 pages · 75,925 characters
Text of OCC-507 Attachment 27.pdf
Extracted from the file · 35 pages · 66,295 characters
Text of OCC-507 Attachment 26.pdf
Extracted from the file · 19 pages · 68,589 characters
Text of OCC-507 Attachment 25.pdf
Extracted from the file · 12 pages · 53,851 characters
Text of OCC-507 Attachment 24.pdf
Extracted from the file · 2 pages · 482 characters
Page 199 of 268
Connecticut Light and Power Company Docket No. 26-05-10 The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 31, 2026 OCC-507 Attachment 23 Page 199 of 268 OCC-507 CL&P Attachment 23 Docket No. 24-10-04 Page 199 of 268 Page 195 Id. The validation test results range from 0 to 1. The closer the test result is to 1, the greater the likelihood that the dependent variable is explained by the independent variables, and the more reliable the econometric models are for the data set. Ex. UI-MP1, p. 14. For the sales delivery R-squared test, residential class test results were 0.967, commercial class results were 0.895, and industrial class results were 0.859. For UI’s customer forecasts, the results of the R-squared test were 0.996 for residential customers, 0.979 for commercial customers, 0.997 for industrial customers, and 0.945 for streetlight customers. The Authority finds that the R-squared test results statistically indicate the econometric model is a good fit for the customer forecast. The MAPE test calculates “the ratio of the absolute value difference between the monthly forecast value derived from the model and the actual monthly value averaged over the entire dataset of values.” 114 Ex. UI-MP-1, pp. 14–15. “The smaller the MAPE, the better the model estimate[d] the dataset.” Id. UI performed forecast tests for billed sales delivery and customers to test the validity of its model over a two-year period. 115 Id. Generally, MAPE results of 10% or less are an indicator that validates the econometric model’s estimate of the dataset. Table 78: MAPE Test of Forecast, Customers Customers Residential Commercial Industrial Streetlight MAPE 2-year Post MAPE 0.11% 0.11% 0.24% 0.45% 0.48% 0.36% 0.28% 0.23% Application, Ex. UI-MP-3, p. 1. Table 79: MAPE Test of Forecast, Sales Delivery Customers Residential Commercial Industrial Streetlight 116 MAPE 2-year Post MAPE 2.84% 3.97% 3.08% 3.76% 0.30% 0.25% - 114UI also described the MAPE as the “Average Absolute Value of the Error divided by the Actual Value.” Application, Ex. UI-MP-3, p. 1. 115UI performed an “Ex Post forecast test” by withholding a portion of data, with the model estimated on the remaining sample and the results compared to the actual (withheld) data. Application, Ex. UI-MP-1, p. 15. “Ex Post forecast tests were performed on all customer and billed unit models . . . for two periods to demonstrate how well the models forecast two years out.” Id. 116As noted above, the Company’s streetlight usage forecast relied on historical data and average growth rates to determine the billed sales forecast; no MAPE analysis was performed with respect to streetlight customers.Page 200 of 268
Connecticut Light and Power Company Docket No. 26-05-10 Docket No. 24-10-04 The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 31, 2026 OCC-507 Attachment 23 Page 200 of 268 OCC-507 CL&P Attachment 23 Page 200 of 268 Page 196 Application, Ex. UI-MP-3, p. 1. The Company provided additional MAPE results for the 2024 forecast that ranged from 0.28% to 5.75% for the billed sales usage and 0.25% to 0.70% for the customer forecast. Interrog. Resp. RRU-11, Att. 1. The Authority finds the Company’s sales and revenues forecast, as well as the Company’s out-of-model adjustments, to be reasonable. Additionally, the risk of misstating unit rates is minimized by revenue decoupling, whereby any under- or over-collection against the approved revenue requirement is either recovered by the Company or returned to ratepayers, respectively, in the next available period. Accordingly, the Authority accepts UI’s sales forecast for the Rate Year without any adjustments. C. COST-OF-SERVICE STUDY The Company filed an allocated cost-of-service study (ACOSS) based on the historical test year and rate year costs and revenues. Application, Ex. UI-BR-1, p. 12. The Company’s proposed ACOSS utilizes the Minimum System Study (MSS) approach to classify distribution assets into customer- and demand-related costs. 117 Id., p. 15. The Company followed the Authority’s directive to use embedded costs rather than replacement costs. See 22-08-08 Decision, p. 228. To arrive at customer-related costs, the Company selected the minimum sized piece of equipment for each cost category and multiplied its embedded cost by the number of units in service. Ex. UI-BR-1, p. 16. The residual demand-related costs were calculated as the difference between total plant costs in each category and the customerrelated costs. Id., pp. 16–17. The MSS approach is one of the two recommended methods in the NARUC Electric Utility Cost Allocation Manual (NARUC Manual). NARUC Manual, p. 90. In its initial proposal, the Company did not attempt to quantify the minimum system’s load carrying capacity, i.e., the delivery capacity of each category of equipment included in the MSS approach. The Authority requested that the Company and OCC submit alternative ACOSS models. Late Filed Ex. 71; Late Filed Ex. 83. The Authority directs the Company to adopt the ACOSS models filed in Late Filed Ex. 71, with the modifications discussed below. The Authority requested that the Company and OCC submit alternative ACOSS models that calculate a per-customer load-carrying capacity value and credit each customer class that value when allocating residual demand-related costs. Late Filed Ex. 71; Late Filed Ex. 83. The Company implemented this request by calculating the load-carrying capacity of transformers and conductors (adjusted by a 90% power factor), then multiplying that capacity by the quantity of deployed equipment (number of transformers for line transformers and number of circuits for conductors), and finally dividing by the number of 117CIEC supports the Company’s use of the MSS approach. Chait Rebuttal Test., Mar. 12, 2025, pp. 1–2. CIEC argues that allocating AMI costs based on the benefits of AMI technology does not constitute costbased allocation. Id., p. 14.Page 201 of 268
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 31, 2026 OCC-507 Attachment 23 Page 201 of 268 Connecticut Light and Power Company Docket No. 26-05-10 OCC-507 CL&P Attachment 23 Page 201 of 268 Docket No. 24-10-04 Page 197 customers in each rate class to arrive at a per-customer load-carrying capacity that was applied to each class’s demand allocator. Late Filed Ex. 71. OCC implemented the Authority’s request by applying a universal load-carrying capacity adjustment to the non-coincident peak demands used to allocate demandrelated costs. Late Filed Ex. 83. In the absence of more granular data, OCC presented two scenarios with adjustment values of 0.4 kW and 1.5 kW, based on recent proceedings in Minnesota and Ontario, respectively. Id. Table 80, below, shows the relative rate of return for each rate class under the Company’s initial ACOSS model, the revised model UI submitted, and the revised models OCC submitted. Table 80: Proposed Relative Rate of Return for Each Rate Class UI UI OCC OCC Initial Proposal Modified LFE-83, 0.4 kW LFE-83, 1.5 kW Rate Class OCC-362, Att. 22 LFE-71, Att. 1 per Customer per Customer R GS GST LPT M U Total 0.03 2.08 4.18 3.85 (1.62) 5.74 1.00 0.52 1.91 2.24 2.04 (1.71) 4.78 1.00 0.32 1.83 3.12 2.68 (1.67) 5.26 1.00 1.92 0.78 (0.29) (0.87) (1.90) 3.33 1.00 OCC suggests that the Company’s original MSS approach was unsound as the basis for determining cost causation and would inflate cost allocations to residential customers. Palmer Prefiled Test., Feb. 13, 2025, p. 9. As an alternative, OCC proposed the basic customer method, in which only costs associated with services, meters, meter reading, and billing are classified as customer related. Id., p. 14. OCC also proposed that the Company allocate “no demand-related costs to the customer classes whose peak demands can generally be met through the identified ‘customer-related’ portion of the system,” if the MSS is approved in any capacity (either for all of distribution plant or only primary distribution). Id., p. 16; Hr’g Tr., 1489:23–1490:2. OCC also states that AMI costs should be classified proportionally according to the benefits in the customer, demand, and energy categories. Id., p. 22. As UI noted, the Authority has accepted the MSS approach in prior rate case proceedings, including the Company’s most recent rate case. Rates Panel Rebuttal Test., Mar. 12, 2025, pp. 7–10. UI challenged OCC's assertion that examining the marginal costs of adding a new customer is a reasonable test for allocating embedded costs. Id., pp. 5–7. The Company also criticized OCC’s recommendation to omit certain customer classes from allocation of demand-related expenses on the grounds that the minimum system is capable of meeting their demands. Id., pp. 11–12. Finally, the Company clarified that while the cost of AMI meters was classified as 100% customer-related, otherPage 202 of 268
Connecticut Light and Power Company Docket No. 26-05-10 Docket No. 24-10-04 The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 31, 2026 OCC-507 Attachment 23 Page 202 of 268 OCC-507 CL&P Attachment 23 Page 202 of 268 Page 198 costs associated with AMI infrastructure were classified using the labor allocator, which has both customer and demand components. Id., pp. 13–14. Although the Authority acknowledges OCC’s concerns with the MSS approach, it is not clear that the basic customer method is a superior alternative. Costs classified as demand-related under the basic customer method, such as poles and conductors, are unaffected by changes in demand. Both the Company and OCC acknowledge that these costs are primarily driven by the geographic dispersion of customers (i.e., circuit miles). Rates Panel Rebuttal PFT, p. 12; Palmer Surrebuttal Test., Mar. 24, 2025, p. 3. Unfortunately, geographic dispersion does not offer a clear billing determinant. As such, the Authority accepts the premise that the number of customers is an acceptable, if imperfect, proxy for costs unrelated to demand, and that the MSS approach is an appropriate method for categorizing these costs in this proceeding. Primary distribution infrastructure has both demand- and customer-related components. Rates Panel Rebuttal, p. 12. Even in a hypothetical sense, there can be no minimum-sized system that contains only secondary distribution while meeting any non de minimis level of demand. Therefore, the reasoning supporting the use of the MSS approach extends to both primary and secondary distribution plant. The Authority affirms the Company’s proposed classification of AMI meters as 100% customer-related, which is consistent with cost causation principles, as argued by CIEC. The MSS approach is a just and reasonable approach to cost classification, but the minimum system’s load-carrying capacity should be considered when allocating residual demand-related costs. The Company did not consider the minimum system’s load-carrying capacity because customers benefit equally from minimum system costs since “all customers impose some lowest common denominator amount of minimum load on the system.” Rates Panel Rebuttal PFT, pp. 11–12; Late Filed Ex. 83. All customers benefit equally from the minimum system, and this benefit can be quantified, although the Company did not attempt to do this. See Hr’g Tr., 1328:19. Specifically, each customer should be allocated an equal share of the load-carrying capacity affiliated with the hypothetical minimum system, applied towards the relevant demand allocators. The Ontario Energy Board approved a similar approach, with an adjustment value of 0.4 kW per customer, following an extensive stakeholder engagement process. Hr’g Tr., 1487:13–15; Palmer Surrebuttal PFT, Att. CP-Surrebuttal-2. OCC incorporated the 0.4 kW per customer adjustment value into a modified ACOSS model, as shown in Table 80, above. See Late Filed Ex. 83, Att. 5. OCC recommended that the Company engage in thoughtful analysis with stakeholder engagement to determine an appropriate adjustment value for its minimum system. Late Filed Ex. 83, p. 1. There is not sufficient time to convene a stakeholder group for this proceeding, however. Accordingly, the Authority determines that it is appropriate to use the Company’s load-carrying capacity adjustment values for poles and conductors, with two modifications. See Late Filed Ex. 71, Att. 4. Specifically, in the Company’s adjusted ACOSS model, the Company applied the adjustment only for line transformers and conductors (overhead and underground). Id. Although the Company did not explain this choice, the Authority assumes that a similar load-carrying capacity adjustment was not applied to poles and conduits because those components do not physically deliver electricity. Conductors and line transformers cannotPage 203 of 268
Connecticut Light and Power Company Docket No. 26-05-10 The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 31, 2026 OCC-507 Attachment 23 Page 203 of 268 OCC-507 CL&P Attachment 23 Docket No. 24-10-04 Page 203 of 268 Page 199 deliver electricity without poles and conductors, however, and these components are assigned a demand-related cost in the minimum system study. Therefore, conductors and line transformers also have an associated load-carrying capacity. The Authority determines that the most reasonable correction is to apply the primary and secondary overhead conductor load-carrying capacity values to primary and secondary poles, respectively, and the underground primary and secondary load-carrying capacity values to primary and secondary conduits, respectively. Table 81, below, shows the final load-carrying capacity adjustments for each equipment type for the Rate Year. Table 81: Rate Year Load-Carrying Capacity Adjustments Equipment Type Primary Overhead Primary Poles Secondary Overhead Secondary Poles Primary Underground Primary UG Conduit Secondary Underground Secondary UG Conduit Line Transformers Capacity per Capacity (kW) Customers Customer (kW) 138,270 349,495 0.396 138,270 349,495 0.396 6,396 349,033 0.018 6,396 349,033 0.018 12,614 349,495 0.036 12,614 349,495 0.036 4,044 349,033 0.012 4,044 349,033 0.012 1,095,525 349,495 3.135 Late Filed Ex. 71, Att. 4. The use of a load-carrying capacity is consistent with the NARUC Manual cited by the Company and CIEC, which states that “[w]hen using this distribution method, the analyst must be aware that the minimum-size distribution equipment has a certain loadcarrying capability, which can be viewed as a demand-related cost.” NARUC Manual, p. 95. This approach helps avoid allocating demand-related costs to customer classes that have already paid for those costs through the customer-related minimum system costs. OCC Brief, p. 149. Omitting certain customer classes based on whose demands can “generally” be met by the minimum system is too imprecise to be a reasonable approach. See Palmer Surrebuttal PFT, p. 5. The Authority directs the Company to adopt the ACOSS models filed in Late Filed Ex. 71, with the modifications outlined above. For resulting allocators that are below zero for a certain class after applying the adjustment, that class should not be assigned any costs in that category, as is currently reflected in Late Filed Ex. 71, Att. 4. Lastly, as part of its next rate amendment application, the Authority directs the Company to further refine the load-carrying capacity adjustment values in alignment withPage 204 of 268
Connecticut Light and Power Company Docket No. 26-05-10 Docket No. 24-10-04 The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 31, 2026 OCC-507 Attachment 23 Page 204 of 268 OCC-507 CL&P Attachment 23 Page 204 of 268 Page 200 OCC’s suggestions, inclusive of stakeholder engagement. 118 Specifically, the Company is directed to (1) propose an alternative ACOSS with a load-carrying capacity adjustment developed in consultation with OCC and other stakeholders, (2) state whether UI recommends the alternative ACOSS, and (3) explain in narrative form why UI does or does not recommend the alternative ACOSS. UI should also explore the use of proxies that align more closely with geographic dispersion as a cost driver, rather than defaulting to MSS, as part of the stakeholder engagement. D. COST ALLOCATION The Company used non-coincident peak (NCP) demand to allocate demandrelated costs from the ACOSS to each customer class, except for costs associated with distribution substations, for which the Company used class-wide coincident demand with system peak (1CP). Ex. UI-BR-1, p. 20. In the final decision in Docket No. 22-08-08, the Authority directed the Company to explore alternative allocators using its AMI data. 2208-08 Decision, p. 243. The Company computed each class’s contribution to substation and feeder peaks using hourly load data, with which it developed weighted allocators. Ex. UI-BR-5. The Company elected not to use these alternative allocators in its ACOSS but stated that the alternative allocators were “very similar” to the NCP and 1CP allocators. Rates Panel Rebuttal PFT, pp. 17–18. To move closer to equalized rates of return (ROR) among customer classes, the Company employed an iterative approach. Application, Ex. UI-RP-1, p. 14. The Company first allowed rate increases equal to 75% to 125% of the average increase across all classes, then reallocated remaining revenues among classes with non-binding constraints. Id. This approach was consistent with the Authority’s directive in the Company’s previous rate case. See 22-08-08 Decision, p. 244. The Company then made a manual adjustment to its model, reducing the lower rate increase constraint from 75% to 50%. Ex. UI-RP-1, p. 15. Although this approach violated the Authority’s 125%/75% rule, it achieved closer ROR parity among customer classes compared to the unadjusted model. Id. UI asserts that its use of the 1CP and NCP allocators in the ACOSS reflects the industry standard. Rates Panel Rebuttal PFT, p. 16. The Company asserts that it “seems reasonable to rely on allocators that are easy to understand and readily available,” compared to the alternative allocators, which were data- and resource-intensive to develop. Id., p. 18. The Company also argued that this simpler approach is the most cost-reflective approach. Hr’g Tr., 1334:14. OCC recommends that the Company use alternative demand allocators for substations and primary feeders. Palmer PFT, p. 30. OCC suggests that UI’s approach to developing alternative demand allocators was reasonable but could be improved by considering such factors as duration of the peak, near-peak hours, and pre-peak loads. 118The phrase “in alignment with OCC’s suggestions” refers to OCC’s suggestions to conduct a stakeholder engagement process to develop an appropriate adjustment value, similar to the process followed by the Ontario Energy Board. The final adjustment value should not be dictated solely by OCC, a concern articulated by CIEC. CIEC Exceptions, p. 6.Page 205 of 268
Connecticut Light and Power Company Docket No. 26-05-10 The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 31, 2026 OCC-507 Attachment 23 Page 205 of 268 OCC-507 CL&P Attachment 23 Docket No. 24-10-04 Page 205 of 268 Page 201 Id., p. 28. OCC suggests that the Authority could balance the opposing results of its proposed class revenue increase (based on the basic customer ACOSS method) by implementing an equal percentage increase for all rate classes. Palmer PFT, p. 33. OCC also noted that the NARUC Manual, on which the Company relied to propose use of the NCP and 1CP allocators, was published in 1992, prior to the advent of AMI, which enables more cost-reflective allocators. Palmer Surrebuttal PFT, p. 12; Hr’g Tr., 1496:22–1497:5. CIEC opposes the Company’s proposed revenue allocation. Chait PFT, p. 12. CIEC states that the Authority has historically allowed for a revenue increase tolerance band outside 75% to 125% if there is significant disparity between class rates of return. Id. CIEC proposes a +/-40% tolerance band to mitigate overcollection from customers on schedules GST, LPT, and U. Id., p. 13. The Company demonstrated analytical rigor in its development of alternative demand allocators; ultimately though, the Company proposed to continue to use NCP and 1CP allocators in its ACOSS due to their simplicity and historical precedent. Nonetheless, the Authority agrees with OCC that the alternative demand allocators better reflect cost causation. The fact that the two approaches produce similar results is not a valid justification to employ a less cost-reflective method, particularly given the possibility that load patterns will shift in the future in response to TOU rates. Unlike rates, it is not important for demand allocators to be easy to understand, and simplicity is not sufficient justification for using an inferior method. However, due to the difficulty of incorporating the load-carrying capacity adjustments outlined in Section VIII.C, Cost-of-Service Study, above, to the alternative demand allocators, the Authority accepts, for this proceeding, the Company’s use of the simple NCP allocators (adjusted for the load-carrying capacity). The Authority directs the Company to adopt the alternative substation allocator for demand-related substation costs. Table 82, below, shows the final allocators for the Rate Year. The substation allocators come from Late File Ex. 71, Att. 3. The remaining allocators come from Late File Ex. 71, Att. 1. Table 82: Demand Allocators Allocator Substation NCP for Transformers NCP Primary – Overhead Conductors and Poles NCP Secondary – Overhead Conductors and Poles NCP Primary – Underground Conductors and Conduit NCP Secondary – Underground Conductors and Conduit R GS GST LPT M U 51.87% 12.23% 23.36% 12.55% 0.00% 0.00% 0.00% 13.04% 63.53% 22.48% 0.77% 0.19% 46.56% 11.33% 27.93% 13.77% 0.33% 0.08% 56.29% 12.02% 24.63% 6.66% 0.32% 0.08% 50.77% 10.95% 25.47% 12.44% 0.30% 0.07% 56.36% 12.01% 24.59% 6.64% 0.32% 0.08% The Authority reviewed the Company’s revenue allocation scheme using the updated ACOSS model outlined in Section VIII.C, Cost-of-Service Study, above. The Company’s approach starts by allocating either the maximum allowable rate increasePage 206 of 268
Connecticut Light and Power Company Docket No. 26-05-10 Docket No. 24-10-04 The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 31, 2026 OCC-507 Attachment 23 Page 206 of 268 OCC-507 CL&P Attachment 23 Page 206 of 268 Page 202 (125% of the class average increase) or the rate increase at equal rates of return (whichever is lower). Interrog. Resp. OCC-362, Att. 38 Second Rev. Supp. The Company then eliminates rate decreases (which occur in cases where the revenue requirement at equal rates of return is lower than the delivery revenues at present) and allocates the remaining revenue shortfall to each class proportional to that class’s base revenue at present, subject to the 125% rule. Id. In the final step, the Company performs a manual adjustment (using hardcoded values) and uses the residential rate class to balance the system to the overall revenue target. Ex. UI-RP-1, p. 15. The resulting revenue requirements yield rate increases equal to 50% of the class-wide average for the GS, GST, LPT, and U rate classes. The Authority finds that after the load-carrying capacity adjustments were made to all components of the minimum system, an alternative revenue allocation approach achieves closer revenue-to-cost (RTC) and ROR parity among the rate classes compared to the Company’s approach without a manual adjustment. 119 Under the alternative revenue allocation approach, in the first step, each class receives the greater of either the minimum increase (i.e., 75% of the class-wide average increase) or the rate increase at equal rates of return. The resulting excess revenue is subtracted from the classes with rate increases higher than the minimum increase, proportional to base distribution revenues at present. The ultimate revenue increases adhere to the 75/125 rule. Table 83, below, lays out the steps for applying the alternative allocation approach, compared to the Company’s approach. 119In implementing this alternative allocation, the Authority discovered an apparent formula error in the Company’s revenue allocation spreadsheet. Interrog. Resp. OCC-362, Att. 38 Second Rev. Supp. (“Revenue Allocation” tab). To calculate the equiproportional rate increase (“Revenue Allocation” tab, ln. 25) for the residential class, the Company subtracted the Delivery Revenue at Present (Line 8) from the Rate Year Revenue at Equiproportional Change (Line 24). Id. However, for the other rate classes, the Company subtracted the Tota Delivery Revenues at Present (Line 10, inclusive of Other Revenues) from the Rate Year Revenue at Equiproportional Change (Line 24). This produced a disparity in the Equiproportional Factor (19.6% in cell D24, 20.0% in cell D25), which impacts the maximum proportional increase cap factor (Line 28) and subsequent calculations. This factor was the subject of another interrogatory response. Interrog. Resp. OCC-685, pp. 1–2. The Authority corrected this error when applying the alternative allocation scheme.Page 207 of 268
Connecticut Light and Power Company Docket No. 26-05-10 The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 31, 2026 OCC-507 Attachment 23 Page 207 of 268 OCC-507 CL&P Attachment 23 Docket No. 24-10-04 Page 207 of 268 Page 203 Table 83: Alternative Revenue Allocation Approach Step 1 2 3 4 Company’s Approach Allocate to each class the lesser of the: (1) maximum allowable increase under 75/125 rule (125% of class-wide average increase) or (2) increase at equalized rates of return. Then, eliminate rate decreases. Calculate the revenue shortfall (the difference between the revenue target and the sum of class revenues in Step 1). For classes below the 125% cap, allocate the revenue shortfall proportional to each class’s base revenue at present. Repeat Step 2 using the remaining revenue shortfall. Perform manual adjustment and use the residential class to balance the system to the overall revenue target. Alternative Approach Allocate to each class the greater of the: (1) minimum allowable increase under 75/125 rule (75% of class-wide average increase) or (2) increase at equalized rates of return. Calculate the revenue excess (the difference between the revenue target and the sum of class revenues in Step 1). For classes above the 75% floor, return the revenue excess proportional to each class’s base revenue at present. Figures 2 through 5 show the class revenue increases, relative ROR values, and relative RTC values for the Company’s proposal compared to the adjusted ACOSS and revenue allocation scheme described in this and the preceding section. Had the Company performed the revenue allocation using the load-carrying capacity-adjusted ACOSS, a different manual adjustment may have been made to move each class closer to ROR and RTC ratios of 1.00. However, in the absence of information on how these manual adjustments were calculated, the Authority was unable to produce a third scenario that used the adjusted ACOSS with the Company’s revenue allocation model. Figure 2, below, shows the rate increases for each rate class, using the Company’s proposal and the adjusted ACOSS with alternative revenue allocation. The percentage increases shown in Figure 2 are based on the Company’s proposed increases, and do not represent the actual increases that will be approved as a result of the revenue requirement approved in this decision. In addition, the Company is directed to make adjustments to the adjusted ACOSS, which are not represented in the results shown in Figure 2.Page 208 of 268
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 31, 2026 OCC-507 Attachment 23 Page 208 of 268 Connecticut Light and Power Company Docket No. 26-05-10 OCC-507 CL&P Attachment 23 Page 208 of 268 Docket No. 24-10-04 Page 204 Figure 2: Rate Increase Comparison Between the Company’s Proposal and Adjusted ACOSS with Alternative Revenue Allocation 25.00% 20.00% 15.00% 10.00% 5.00% 0.00% (R) & (RT) (GS) Company Proposal (GST) (LPT) (M) (U) Adjusted ACOSS and Alternative Rev Alloc Table 84 shows the rate increases for each class (absolute and percentage increases) used to produce Figure 2, based on the Company’s proposed increases. Table 84: Rate Increases Based on UI’s Proposed Revenue Requirement R and RT GS GST LPT M U Company Proposal $62,106,593 $3,797,425 $6,225,275 $2,457,460 $1,705,802 $54,256 Absolute Adjusted ACOSS & Increase Alt. Rev. Allocation $55,696,050 $5,696,138 $9,337,912 $3,830,893 $1,704,434 $81,383 Company Proposal 24.40% 9.81% 9.81% 9.81% 24.52% 9.81% Adjusted ACOSS Percent and Alt. Rev. Increase Allocation 21.89% 14.71% 14.71% 15.29% 24.50% 14.71% Figure 3, below, shows the rate increases for each rate class relative to the class average increase, using the Company’s proposal and the adjusted ACOSS with alternative revenue allocation. The adjusted ACOSS with alternative revenue allocation adheres to the 75/125 rule, whereas the Company’s proposal permits rate increases equal to 50% of the class average for the GS, GST, LPT, and U classes.
Text of OCC-507 Attachment 22.pdf
Extracted from the file · 178 pages · 528,336 characters
Text of OCC-507 Attachment 21.pdf
Extracted from the file · 296 pages · 1,013,669 characters
Text of OCC-507 Attachment 20.pdf
Extracted from the file · 167 pages · 508,170 characters
Text of OCC-507 Attachment 19.pdf
Extracted from the file · 137 pages · 450,996 characters
Text of OCC-507 Attachment 18.pdf
Extracted from the file · 247 pages · 763,200 characters
Text of OCC-507 Attachment 17.pdf
Extracted from the file · 2 pages · 6,387 characters
Text of OCC-507 Attachment 16.pdf
Extracted from the file · 2 pages · 484 characters
Text of OCC-507 Attachment 15.pdf
Extracted from the file · 202 pages · 895,816 characters
Text of OCC-507 Attachment 14.pdf
Extracted from the file · 6 pages · 8,947 characters
Text of OCC-507 Attachment 13.pdf
Extracted from the file · 19 pages · 93,122 characters
Text of OCC-507 Attachment 12.pdf
Extracted from the file · 19 pages · 95,631 characters
Text of OCC-507 Attachment 11.pdf
Extracted from the file · 7 pages · 10,667 characters
Text of OCC-507 Attachment 8.pdf
Extracted from the file · 2 pages · 3,673 characters
Text of OCC-507 Attachment 4.pdf
Extracted from the file · 6 pages · 8,272 characters
Text of OCC-507 Attachment 2.pdf
Extracted from the file · 8 pages · 30,345 characters
Text of OCC-507 Attachment 1.pdf
Extracted from the file · 32 pages · 164,962 characters
Text of OCC-507 Attachment 39.pdf
Extracted from the file · 22 pages · 32,510 characters
Text of OCC-507 Attachment 31.pdf
Extracted from the file · 8 pages · 37,747 characters
Text of OCC-507 Attachment 30.pdf
Extracted from the file · 5 pages · 22,063 characters
Text of OCC-507 Attachment 10.pdf
Extracted from the file · 3 pages · 4,485 characters
Text of OCC-507 Attachment 9.pdf
Extracted from the file · 10 pages · 15,175 characters
Text of OCC-507 Attachment 7.pdf
Extracted from the file · 3 pages · 5,747 characters
Text of OCC-507 Attachment 6.pdf
Extracted from the file · 4 pages · 6,545 characters
Text of OCC-507 Attachment 5.pdf
Extracted from the file · 4 pages · 5,724 characters
Text of OCC-507 Attachment 3.pdf
Extracted from the file · 65 pages · 195,008 characters
As listed on the current system
Question(s) Answered 507, 508, 509, 510, 511, 512, 517, 518 (The Connecticut Light and Power Company dba Eversource Energy) Date Filed: 09/14/2026