Interrogatory responses
Answers to questions 507, 508, 509, 510, 511, 512, 517, 518
Files53
OCC-507_Final.pdf
PDF · 195 KB · 6 pagesText searchable
Download OCC-507_Final.pdfRead the text of OCC-507_Final.pdf
OCC-508_Final.pdf
PDF · 81 KB · 1 pageText searchable
Download OCC-508_Final.pdfRead the text of OCC-508_Final.pdf
OCC-509_Final.pdf
PDF · 86 KB · 1 pageText searchable
Download OCC-509_Final.pdfRead the text of OCC-509_Final.pdf
OCC-510_Final.pdf
PDF · 190 KB · 3 pagesText searchable
Download OCC-510_Final.pdfRead the text of OCC-510_Final.pdf
OCC-511_Final.pdf
PDF · 215 KB · 8 pagesText searchable
Download OCC-511_Final.pdfRead the text of OCC-511_Final.pdf
OCC-512_Final.pdf
PDF · 82 KB · 1 pageText searchable
Download OCC-512_Final.pdfRead the text of OCC-512_Final.pdf
OCC-517_Final.pdf
PDF · 131 KB · 1 pageText searchable
Download OCC-517_Final.pdfRead the text of OCC-517_Final.pdf
OCC-518_Final.pdf
PDF · 81 KB · 1 pageText searchable
Download OCC-518_Final.pdfRead the text of OCC-518_Final.pdf
OCC-512 Attachment 3 REDACTED.pdf
PDF · 5.2 MB · 33 pagesText searchable
Download OCC-512 Attachment 3 REDACTED.pdfRead the text of OCC-512 Attachment 3 REDACTED.pdf
OCC-512 Attachment 2 REDACTED.pdf
PDF · 6.8 MB · 33 pagesText searchable
Download OCC-512 Attachment 2 REDACTED.pdfRead the text of OCC-512 Attachment 2 REDACTED.pdf
OCC-512 Attachment 1.pdf
PDF · 23 MB · 626 pagesText searchable
Download OCC-512 Attachment 1.pdfRead the text of OCC-512 Attachment 1.pdf
OCC-507 Attachment 42.pdf
PDF · 1.7 MB · 3 pagesText searchable
Download OCC-507 Attachment 42.pdfRead the text of OCC-507 Attachment 42.pdf
OCC-507 Attachment 41.pdf
PDF · 1.8 MB · 9 pagesText searchable
Download OCC-507 Attachment 41.pdfRead the text of OCC-507 Attachment 41.pdf
OCC-507 Attachment 40.pdf
PDF · 2.2 MB · 5 pagesText searchable
Download OCC-507 Attachment 40.pdfRead the text of OCC-507 Attachment 40.pdf
OCC-507 Attachment 38.pdf
PDF · 4.6 MB · 19 pagesText searchable
Download OCC-507 Attachment 38.pdfRead the text of OCC-507 Attachment 38.pdf
OCC-507 Attachment 37.pdf
PDF · 2.9 MB · 49 pagesText searchable
Download OCC-507 Attachment 37.pdfRead the text of OCC-507 Attachment 37.pdf
OCC-507 Attachment 36.pdf
PDF · 2.9 MB · 59 pagesText searchable
Download OCC-507 Attachment 36.pdfRead the text of OCC-507 Attachment 36.pdf
OCC-507 Attachment 35.pdf
PDF · 4.3 MB · 38 pagesText searchable
Download OCC-507 Attachment 35.pdfRead the text of OCC-507 Attachment 35.pdf
OCC-507 Attachment 34.pdf
PDF · 2.1 MB · 5 pagesText searchable
Download OCC-507 Attachment 34.pdfRead the text of OCC-507 Attachment 34.pdf
OCC-507 Attachment 33.pdf
PDF · 2.9 MB · 13 pagesText searchable
Download OCC-507 Attachment 33.pdfRead the text of OCC-507 Attachment 33.pdf
OCC-507 Attachment 32.pdf
PDF · 1.6 MB · 5 pagesText searchable
Download OCC-507 Attachment 32.pdfRead the text of OCC-507 Attachment 32.pdf
OCC-507 Attachment 29.pdf
PDF · 1.8 MB · 8 pagesText searchable
Download OCC-507 Attachment 29.pdfRead the text of OCC-507 Attachment 29.pdf
OCC-507 Attachment 28.pdf
PDF · 2.5 MB · 18 pagesText searchable
Download OCC-507 Attachment 28.pdfRead the text of OCC-507 Attachment 28.pdf
OCC-507 Attachment 27.pdf
PDF · 3.0 MB · 35 pagesText searchable
Download OCC-507 Attachment 27.pdfRead the text of OCC-507 Attachment 27.pdf
OCC-507 Attachment 26.pdf
PDF · 5.0 MB · 19 pagesText searchable
Download OCC-507 Attachment 26.pdfRead the text of OCC-507 Attachment 26.pdf
OCC-507 Attachment 25.pdf
PDF · 2.0 MB · 12 pagesText searchable
Download OCC-507 Attachment 25.pdfRead the text of OCC-507 Attachment 25.pdf
OCC-507 Attachment 24.pdf
PDF · 1.5 MB · 2 pagesText searchable
Download OCC-507 Attachment 24.pdfRead the text of OCC-507 Attachment 24.pdf
OCC-507 Attachment 23.pdf
PDF · 21 MB · 268 pagesText searchable
Download OCC-507 Attachment 23.pdfRead the text of OCC-507 Attachment 23.pdf
OCC-507 Attachment 22.pdf
PDF · 25 MB · 178 pagesText searchable
Download OCC-507 Attachment 22.pdfRead the text of OCC-507 Attachment 22.pdf
OCC-507 Attachment 21.pdf
PDF · 38 MB · 296 pagesText searchable
Download OCC-507 Attachment 21.pdfRead the text of OCC-507 Attachment 21.pdf
OCC-507 Attachment 20.pdf
PDF · 22 MB · 167 pagesText searchable
Download OCC-507 Attachment 20.pdfRead the text of OCC-507 Attachment 20.pdf
OCC-507 Attachment 19.pdf
PDF · 9.1 MB · 137 pagesText searchable
Download OCC-507 Attachment 19.pdfRead the text of OCC-507 Attachment 19.pdf
OCC-507 Attachment 18.pdf
PDF · 17 MB · 247 pagesText searchable
Download OCC-507 Attachment 18.pdfRead the text of OCC-507 Attachment 18.pdf
OCC-507 Attachment 17.pdf
PDF · 1.4 MB · 2 pagesText searchable
Download OCC-507 Attachment 17.pdfRead the text of OCC-507 Attachment 17.pdf
OCC-507 Attachment 16.pdf
PDF · 1.4 MB · 2 pagesText searchable
Download OCC-507 Attachment 16.pdfRead the text of OCC-507 Attachment 16.pdf
OCC-507 Attachment 15.pdf
PDF · 32 MB · 202 pagesText searchable
Download OCC-507 Attachment 15.pdfRead the text of OCC-507 Attachment 15.pdf
OCC-507 Attachment 14.pdf
PDF · 2.6 MB · 6 pagesText searchable
Download OCC-507 Attachment 14.pdfRead the text of OCC-507 Attachment 14.pdf
OCC-507 Attachment 13.pdf
PDF · 4.8 MB · 19 pagesText searchable
Download OCC-507 Attachment 13.pdfRead the text of OCC-507 Attachment 13.pdf
OCC-507 Attachment 12.pdf
PDF · 4.6 MB · 19 pagesText searchable
Download OCC-507 Attachment 12.pdfRead the text of OCC-507 Attachment 12.pdf
OCC-507 Attachment 11.pdf
PDF · 4.9 MB · 7 pagesText searchable
Download OCC-507 Attachment 11.pdfRead the text of OCC-507 Attachment 11.pdf
OCC-507 Attachment 8.pdf
PDF · 1.4 MB · 2 pagesText searchable
Download OCC-507 Attachment 8.pdfRead the text of OCC-507 Attachment 8.pdf
OCC-507 Attachment 4.pdf
PDF · 2.6 MB · 6 pagesText searchable
Download OCC-507 Attachment 4.pdfRead the text of OCC-507 Attachment 4.pdf
OCC-507 Attachment 2.pdf
PDF · 2.2 MB · 8 pagesText searchable
Download OCC-507 Attachment 2.pdfRead the text of OCC-507 Attachment 2.pdf
OCC-507 Attachment 1.pdf
PDF · 3.5 MB · 32 pagesText searchable
Download OCC-507 Attachment 1.pdfRead the text of OCC-507 Attachment 1.pdf
OCC-507 Attachment 39.pdf
PDF · 1.5 MB · 22 pagesText searchable
Download OCC-507 Attachment 39.pdfRead the text of OCC-507 Attachment 39.pdf
OCC-507 Attachment 31.pdf
PDF · 1.8 MB · 8 pagesText searchable
Download OCC-507 Attachment 31.pdfRead the text of OCC-507 Attachment 31.pdf
OCC-507 Attachment 30.pdf
PDF · 1.9 MB · 5 pagesText searchable
Download OCC-507 Attachment 30.pdfRead the text of OCC-507 Attachment 30.pdf
OCC-507 Attachment 10.pdf
PDF · 1.6 MB · 3 pagesText searchable
Download OCC-507 Attachment 10.pdfRead the text of OCC-507 Attachment 10.pdf
OCC-507 Attachment 9.pdf
PDF · 6.2 MB · 10 pagesText searchable
Download OCC-507 Attachment 9.pdfRead the text of OCC-507 Attachment 9.pdf
OCC-507 Attachment 7.pdf
PDF · 1.5 MB · 3 pagesText searchable
Download OCC-507 Attachment 7.pdfRead the text of OCC-507 Attachment 7.pdf
OCC-507 Attachment 6.pdf
PDF · 1.5 MB · 4 pagesText searchable
Download OCC-507 Attachment 6.pdfRead the text of OCC-507 Attachment 6.pdf
OCC-507 Attachment 5.pdf
PDF · 1.5 MB · 4 pagesText searchable
Download OCC-507 Attachment 5.pdfRead the text of OCC-507 Attachment 5.pdf
OCC-507 Attachment 3.pdf
PDF · 5.4 MB · 65 pagesText searchable
Download OCC-507 Attachment 3.pdfRead the text of OCC-507 Attachment 3.pdf
Text of OCC-510_Final.pdf
Extracted from the file · 3 pages · 6,553 characters
Text of OCC-511_Final.pdf
Extracted from the file · 8 pages · 17,894 characters
Text of OCC-512_Final.pdf
Extracted from the file · 1 page · 992 characters
Text of OCC-517_Final.pdf
Extracted from the file · 1 page · 826 characters
Text of OCC-518_Final.pdf
Extracted from the file · 1 page · 601 characters
Text of OCC-512 Attachment 3 REDACTED.pdf
Extracted from the file · 33 pages · 5,436 characters
Text of OCC-512 Attachment 2 REDACTED.pdf
Extracted from the file · 33 pages · 5,436 characters
Text of OCC-512 Attachment 1.pdf
Extracted from the file · 626 pages · 635,148 characters
Text of OCC-507 Attachment 42.pdf
Extracted from the file · 3 pages · 10,259 characters
Text of OCC-507 Attachment 41.pdf
Extracted from the file · 9 pages · 3,276 characters
Text of OCC-507 Attachment 40.pdf
Extracted from the file · 5 pages · 8,775 characters
Text of OCC-507 Attachment 38.pdf
Extracted from the file · 19 pages · 96,311 characters
Text of OCC-507 Attachment 37.pdf
Extracted from the file · 49 pages · 120,692 characters
Text of OCC-507 Attachment 36.pdf
Extracted from the file · 59 pages · 136,630 characters
Text of OCC-507 Attachment 35.pdf
Extracted from the file · 38 pages · 102,807 characters
Text of OCC-507 Attachment 34.pdf
Extracted from the file · 5 pages · 1,210 characters
Text of OCC-507 Attachment 33.pdf
Extracted from the file · 13 pages · 52,489 characters
Text of OCC-507 Attachment 32.pdf
Extracted from the file · 5 pages · 14,030 characters
Text of OCC-507 Attachment 29.pdf
Extracted from the file · 8 pages · 37,747 characters
Text of OCC-507 Attachment 28.pdf
Extracted from the file · 18 pages · 75,925 characters
Text of OCC-507 Attachment 27.pdf
Extracted from the file · 35 pages · 66,295 characters
Text of OCC-507 Attachment 26.pdf
Extracted from the file · 19 pages · 68,589 characters
Text of OCC-507 Attachment 25.pdf
Extracted from the file · 12 pages · 53,851 characters
Text of OCC-507 Attachment 24.pdf
Extracted from the file · 2 pages · 482 characters
Page 39 of 268
Connecticut Light and Power Company Docket No. 26-05-10 The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 31, 2026 OCC-507 Attachment 23 Page 39 of 268 OCC-507 CL&P Attachment 23 Docket No. 24-10-04 Page 39 of 268 Page 35 estimated Non-Hardship Uncollectible factor against total active Customer Accounts Receivable.” Interrog. Resp. RRU-65, Att. 1, p. 1. The adjustments to the reserve balance reflect uncollectible factors, which are used to determine the levels of customers’ account receivables to be written off as bad debt expenses. The growth in bad debt expenses correspondingly increases the allowance for bad debts. Interrog. Resp. RRU65, Att. 1, pp. 1–3. The bad debt or uncollectible expenses allowed in rate cases are based on averages of historical uncollectible factors or expenses. The uncollectible expense that the Company reflected as a credit in the working capital calculation only returned about 30% of the annual uncollectible expense, not the total amount in the allowance for bad debts. In addition, there is no double counting of uncollectible expense in the cash working capital and as the allowance for bad debts, because the Authority approves the O&M approach to calculating cash working capital. 32 F. REGULATORY ASSETS The Company proposes including regulatory assets with an average Rate Year balance of $55,863,788 in rate base. The Authority instead allows costs relating to the regulatory assets contained in Table 14, below, to be treated as O&M expenses and amortized outside of rate base, as detailed in Section VI, Allowable Expenses, below. Table 14: Adjustments to Regulatory Assets Proforma Rate Year Beginning Balance Category ($) Regulatory Asset - SFAS 158 57,317,577 Pension Cost Recovery 1,853,470 Environmental Deferral 481,664 Isaias Penalty Over-Under 144,785 Regulatory Proceeding Costs 1,275,258 Total 61,072,754 Proposed Approved Rate Year PURA Rate Year Average Adjustment Average ($) ($) ($) 53,986,199 (53,986,199) 926,735 (926,735) 240,832 (240,832) 72,393 (72,393) 637,629 (637,629) 55,863,788 (55,863,788) - Late Filed Ex. 1, Att. 2 Supp., Sch. B-1.0, Sch. B-6.0, Sch. WP C-3.21. G. PREPAID EXPENSES UI proposed and included in rate base a Rate Year average balance of $4,485,635 for prepaid expenses or prepayments, which includes $2,581,320 for prepaid software maintenance costs as well as costs related to the PURA Assessment. Late Filed Ex. 1, Att. 2 Supp., Sch. B-1.0; Sch. B-5.0; Interrog. Resp. RRU-57, Att. 1. UI initially agreed that $784,365 for the PURA Assessment should be removed from rate base because of a “potential overlap,” due to the same amount being included the Company’s proposed cash working capital. See Interrog. Resp. OCC-557. However, the Company ultimately 32OCC’s witness also recommends that the working capital allowance calculation should not include uncollectible expense, and explains, therefore, that the Company’s argument of a double counting would not apply. Defever Errata Prefiled Test, Feb. 24, 2025, p. 6.Page 40 of 268
Connecticut Light and Power Company Docket No. 26-05-10 The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 31, 2026 OCC-507 Attachment 23 Page 40 of 268 OCC-507 CL&P Attachment 23 Docket No. 24-10-04 Page 40 of 268 Page 36 included approximately $392,183 or 50% of the $784,365 in the proposed average rate base. Late Filed Ex. 1, Att. 2 Supp., Sch. B-1.0; Sch. B-5.0. The PURA Assessment is not appropriately included in the approved prepaid expenses and, accordingly, the Authority does not allow $392,183 of UI’s proposed average rate base. In addition, the Authority does not include $1,288,688 in proposed prepaid expenses for software maintenance. In the aggregate, the Authority approves the inclusion of $2,804,764 prepaid expenses and does not allow $1,680,871 of the Company’s proposed costs in rate base, as shown in Table 15, below. Table 15: Summary of Approved Prepaid Expenses, Average Rate Year Category Insurance Fibertech PURA Assessment SBC Loan Transmission ROW Workers Comp Software Maintenance Other Total Proposed Adjustment Approved ($) ($) ($) 820,558 820,558 137,837 137,837 392,183 (392,183) 198,887 198,887 101,612 101,612 199,683 199,683 2,581,320 (1,288,688) 1,292,632 53,554 53,554 4,485,635 (1,680,871) 2,804,764 UI indicated that the main cause of the increase in the software maintenance prepaid expenses is that “the Company’s Operational Smart Grids organization began using the prepaid process in 2022 to enhance efficiencies, evenly distribute costs over the contract period, and secure vendor discounts with multi-year agreements.” Interrog. Resp. RRU-57. The prepaid software maintenance cost increased from $0 in 2021 to $366,014 in 2022 and $3,431,685 in 2023, which is the primary reason for the difference in the total prepaid expense balances between 2022 and 2023. See Late Filed Ex. 1, Att. 2 Supp., Sch. B-1.0, Sch. B-5.0; Interrog. Resp. RRU-57, Att. 1. The average prepaid expense in UI’s proposed rate base is $4,485,635 [($5,026,573 + $3,944,646) / 2]. The proposed average prepaid amount includes an average of $2,581,320 ([$2,730,076 + $2,432,564] / 2) for software maintenance expenses. See Late Filed Ex. 1, Att. 2 Supp., Sch. B-5.0. Table 16, below, shows UI’s proposed prepaid expenses.Page 41 of 268
Connecticut Light and Power Company Docket No. 26-05-10 The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 31, 2026 OCC-507 Attachment 23 Page 41 of 268 OCC-507 CL&P Attachment 23 Page 41 of 268 Docket No. 24-10-04 Page 37 Table 16: Summary of Proposed Prepaid Expenses Category Insurance Fibertech PURA Assessment SBC Loan Transmission ROW Workers Comp Software Maintenance Other Total Rate Year Rate Year Test Year Proforma Beginning Proforma Ending 2023 Adjustment Balance Adjustment Balance ($) ($) ($) ($) ($) 1,031,435 (210,877) 820,558 820,558 173,260 (35,423) 137,837 137,837 985,941 (201,576) 784,365 (784,365) 250,000 (51,113) 198,887 198,887 127,726 (26,114) 101,612 101,612 251,000 (51,317) 199,683 199,683 3,431,685 (701,609) 2,730,076 (297,512) 2,432,564 18,984 34,570 53,554 53,554 6,270,031 (1,243,458) 5,026,573 (1,081,877) 3,944,696 Late Filed Ex. 1, Att. 2 Supp., Sch. B-5.0; Interrog. Resp. RRU-57, Att. 1. The Company’s proposed balances for software maintenance costs included in the calculation of the proposed average prepaid expense are overstated. UI failed to correctly reflect the 2024 pro forma adjustment and employed incorrect 2024 and 2025 amortization expenses for the prepaid software maintenance expense. First, UI included the 2024 pro forma adjustment as $701,609, instead of a 2024 pro forma adjustment of $166,986 and an amortization of $988,966. 33 See Late Filed Ex. 1, Att. 2 Supp., Sch. B5.0 (column H “Pro Forma Adjustments”); Interrog. Resp. RRU-57, Att. 1, p. 1 (column P “2024 Adjustments” and column T, “2024 Total Charged to Expense”). UI also improperly calculated the 2025 amortization expenses for the prepaid software maintenance expense; the reported “2025 Total Charged to Expense” of $637,599 must be prorated for the 10 months of 2025 that precede the Rate Year. Accordingly, the 10-month amortization expense through October 31, 2025, is $531,332. Accordingly, as shown in Table 17, below, $1,292,632 of UI’s proposed prepaid costs for software maintenance are included in rate base. Table 17: Adjustment to Proposed Average Prepaid Software Maintenance Category 2023 Ending Balance 2024 Proforma Adjustment 2024 Amortization Expense 2025 10-Month Amortization Expense (October)1 Balance as of November 1, 2025 Identifier A B C D E=A+B+C+D Amount ($) 3,544,347 (166,986) (988,966) (531,332) 1,857,063 33The Company reported individual 2024 expenses totaling $988,966 but summed those expenses as $268,446. Interrog. Resp. RRU-57, Att. 1, p. 1 (column T, “2024 Total Charged to Expense”).Page 42 of 268
Connecticut Light and Power Company Docket No. 26-05-10 The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 31, 2026 OCC-507 Attachment 23 Page 42 of 268 OCC-507 CL&P Attachment 23 Docket No. 24-10-04 Page 42 of 268 Page 38 Amount Category Identifier ($) Distribution Portion at 79.55% (as of November 1, 2025) F= E x 79.55% 1,477,294 Rate Year Amortization Based on 48 months G=F/4 (369,323) Balance as of October 31, 2026 H=F+G 1,107,970 Allowed Average Software Maintenance in Rate Base I=F/2+H/2 1,292,632 Proposed Average Software Maintenance in Rate Base J 2,581,320 Adjustment to Average Software Maintenance in Rate Base K=I-J (1,288,688) Late Filed Ex. 1, Att. 2 Supp., Sch. B-5.0; Interrog. Resp. RRU-57, Att. 1. H. DEFERRED EXPENSES AND CREDITS 1. Summary The Company proposed a total rate base balance of $36,575,480 related to deferred expenses and credits. The Authority will exclude $36,575,480 of the Company’s deferred expenses from rate base, as summarized in Table 18, below. Instead, the Company will be permitted to recover total deferred expenses of $28,942,312 as amortized O&M expenses, as detailed in Section VI.A.17, Other Deferred Expenses. Table 18: Summary of Approved Deferred Expenses (Credits) Proposed Balance Approved Balance as of Nov. 1, 2025 Adjustment as of Nov. 1, 2025 Deferred Expense (Credit) ($) ($) ($) Pension deferral 6,767,774 (6,767,774) OPEB deferral (284,085) 284,085 Storm deferral (22-08-08 Balance) 9,453,741 (9,453,741) COVID deferral 1,862,157 (1,862,157) CAM GET deferral (1,026,348) 1,026,348 Isaias Penalty Over/(Under) (16,867) 16,867 Pension deferral – Interim Period 1,853,470 (1,853,470) OPEB Deferral – Interim Period (979,774) 979,774 Isaias Customer Credit Over/(Under) 144,785 (144,785) Storm deferral – New (2,073,381) (2,073,381) Environmental deferral 481,664 (481,664) Fee Free Program deferral (1,852,863) 1,852,863 Regulatory proceeding costs 1,275,258 (1,275,258) Earnings Sharing Mechanism Over/(Under) 276,191 (276,191) Rate Case Expense 3,163,323 (3,163,323) Water Heater Rental Program – Phase Out 12,019,711 (12,019,711) Storm deferral – 2025 Event 5,510,724 (5,510,724) Total 36,575,480 (36,575,480) - See Application, Sch. B-6.0, Sch. WPC-3.21, pp. 1–3, Ex. RRP-22D, pp. 1–8.Page 43 of 268
Connecticut Light and Power Company Docket No. 26-05-10 The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 31, 2026 OCC-507 Attachment 23 Page 43 of 268 OCC-507 CL&P Attachment 23 Docket No. 24-10-04 I. Page 43 of 268 Page 39 ACCUMULATED DEFERRED INCOME TAXES 1. Summary The Company proposes net accumulated deferred income taxes (ADIT) of $317,795,723 to offset rate base proposed for the Rate Year. Late Filed Ex. 1, Att. 2 Supp.; Sch. B-7.0; Sch. WP B-7.0. The ADIT amount represents the average of the Rate Year beginning balance of $319,289,753 and ending balance of $316,303,692. Id. Consistent with accepted utility ratemaking practice, the Company uses net ADIT to offset rate base. Here, the Company proposed an offset of $317,795,723 consisting of FERC Account-related, plant-related, and deferral-related ADIT. The Authority will adjust net ADIT by $1,017,632, as summarized in Table 20 below. Table 19: Summary of Proposed and Approved ADIT Category Proposed ($) Adjustment ($) Approved ($) FERC Account-Related (318,332,191) (318,332,191) Regulatory Asset/Liability-Related 2,105,858 (1,797,791) 308,067 Excess ADIT 2,158,805 2,158,805 Plant-Related (3,728,194) 3,217,604 (510,590) Provision for Deferred Income Taxes (402,181) (402,181) Total (317,795,723) 1,017,632 (316,778,090) 2. Plant Related Adjustments The Authority utilized the outputs from the Plant Model (modified for PURA adjustments) to calculate a revised Rate Year plant-related ADIT balance. 34 The Company proposed an average plant-related ADIT balance of ($3,728,194). 35 The Authority approves an average plant-related ADIT balance of ($510,590) based on a $3,217,604 adjustment. Specifically, the plant-related ADIT adjustment reflects the reduction in deferred tax liability corresponding to the Authority’s adjustments to the Company’s plant-inservice. The Authority derived the adjustment from the Plant Model by computing the difference in deferred tax amounts before and after incorporating the Authority’s plant adjustments. The Authority calculated the difference in plant-related ADIT for the period prior to the beginning of the Rate Year as $2,200,124. The Authority then calculated the difference in ADIT for the rate year as $1,017,479. To reflect the average rate base convention, the balance for the Rate Year was reflected at 50%. The Authority computed 34The Authority identified an apparent error on tab 6 (“6-DepreciationExpense”) of the Plant Model. Specifically, the Company left the June 2024 balance on line 13 (cell V32) blank. The Authority corrected this error for purposes of its calculations. 35This figure was derived by summing cell D62 and one-half of cell D63 from the Plant Model, tab 1.2 (“1.2SummaryRRInput”).Page 44 of 268
Connecticut Light and Power Company Docket No. 26-05-10 The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 31, 2026 OCC-507 Attachment 23 Page 44 of 268 OCC-507 CL&P Attachment 23 Docket No. 24-10-04 Page 44 of 268 Page 40 the resulting adjustment to plant-related ADIT as: $2,200,124 + ($2,034,959 x 50%) = $3,217,604. 36 See Late Filed Ex. 1, Att. 2, Sch. B-7.0; Late Filed Ex. 1, Att. 3, Sch. 1.2. 3. Provision for Deferred Income Taxes The Authority reduces the Company’s proposed depreciation expense by $2,923,090. Thus, based on an income tax composite rate of 27.5175%, the Authority increases the Company’s provision for deferred income tax by $804,361 ($2,923,090 x 27.5175%). As a result, the Company’s average ADIT increases by $402,181 ($804,361 x 50%). 4. Regulatory Asset/Liability Related Adjustments The Company reports deferred income tax (DIT) asset balances related to regulatory assets and liabilities of $649,895 as of October 31, 2025, and $3,561,820 as of October 31, 2026. Late Filed Ex. 1, Att. 2 Supp., Sch WP B-7.0. The Company’s average DIT asset related to regulatory assets and liabilities for the Rate Year is $2,105,858 (($649,895 + $3,561,820) / 2). Id. The Authority reduces this amount by $1,797,791 to reflect changes made in this Decision. As discussed in Section IV.F, Regulatory Assets, above, the Authority excludes $55,863,788 of the Company’s proposed regulatory assets from rate base. Also, as discussed in Section IV.E, Reserves and Regulatory Liabilities, above, the Authority removes $62,386,149 from the Company’s proposed average rate base. These adjustments resulted in a net reduction to the proposed reserves/regulatory liabilities of $6,522,362 ($62,386,149 - $55,863,788). Thus, the Company’s proposed ADIT for Regulatory Asset/Liability Related Changes is reduced by $1,794,791 ($6,522,362 x 27.5175%). The Authority allows ADIT for regulatory asset/liability related changes of $308,067 ($2,105,858 - $1,794,791) in the average rate base. Table 20: Allowed Regulatory Asset/Liability Rate Year Balance Category Amount ($) Total Regulatory Asset Adjustments 55,863,788 Total Reserve/Regulatory Liability Adjustments (62,386,149) Net Reduction to Reserves/Regulatory Liabilities (6,522,362) Late Filed Ex. 1, Att. 2 Supp., Sch. WP B-6.0, Sch. WP B-8.0. 36This figure is calculated as the difference between the Company’s proposed plant-related ADIT balance and the sum of (1) Deferred Income Tax from January 2024 through October 2025 and (2) one-half of Deferred Income Tax from November 2025 through October 2026, as shown on tab 9 (“9DeferredIncomeTaxes”) of the Plant Model (adjusted for PURA plant disallowances). See Late Filed Ex. 1, Att. 3 (“9-DeferredIncomeTaxes” tab).Page 45 of 268
Connecticut Light and Power Company Docket No. 26-05-10 The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 31, 2026 OCC-507 Attachment 23 Page 45 of 268 OCC-507 CL&P Attachment 23 Docket No. 24-10-04 J. Page 45 of 268 Page 41 CAPITAL PLAN 1. Summary As part of its capital plan, UI must comply with Reliability Framework requirements and Resilience Framework requirements as well as create a Climate Change and Vulnerability Plan. As discussed below, UI’s capital plan complies with those requirements. 2. Compliance with the Reliability Framework UI’s Reliability Plan complies with the Reliability Framework requirements established by the Authority on August 31, 2022. See Decision, Aug. 31, 2022, Docket No. 17-12-03RE08, PURA Investigation into the Distribution System Planning of the Electric Distribution Companies – Resilience and Reliability Standards and Programs (1712-03RE08 Decision), pp. 35-57. The Authority established the Reliability Framework “to incentivize programs that maintain consistent top-quartile reliability performance while minimizing or reducing ratepayer impact.” Id., p. 42. To accomplish this, the Reliability Framework outlined planning parameters that should enable UI to maintain top quartile reliability, while also improving upon it when necessary or cost-effective to do so. Id., p. 43. Multi-year reliability investment plans must include an analysis that targets a 5% bluesky reliability improvement over prior four year-average reliability improvement. Id., p. 44. The 5% improvement is a planning parameter, not a standard. Id. The plan may depend also on (1) whether the Company achieved top-quartile reliability performance in the prior four years, (2) whether the Company achieved General Statutes § 16-244i(d) reliability targets in the last 10 years, and (3) an affordability analysis. Id. The affordability analysis is done by analyzing the past 10-year “baseline” reliability category spending and then escalating those costs by the GDP Deflator index as published by the U.S. Bureau of Economic Analysis. Id., p. 45. If the proposed UI reliability investment plan exceeds the affordability analysis, then UI must include some reliability improvement target for the incremental spend. Id., p. 46. If the proposed budget is under the threshold, UI may target a 0% reliability improvement. Id. UI may also propose a different affordability definition (i.e., threshold analysis). Id. First, UI has achieved top-quartile reliability performance as measured by both System Average Interruption Duration Index (SAIDI) and System Average Interruption Frequency Index (SAIFI) from 2019-2023 (both comparing to utilities nationally and in the northeast). Interrog. Resp. OCC-581. Second, the Company met minimum reliability thresholds articulated in General Statutes § 16-244i(d) from 2014-2023 with two exceptions. In 2014 and in 2018, UI exceeded the General Statutes § 16-244i(d) threshold for SAIDI. All other years were under the threshold for both SAIDI and SAIFI. When looking at the four-year rolling average, UI did not exceed the threshold for SAIDI or SAIFI. Interrog. Resp. RSR-191, Att. 1. Third, regarding the affordability analysis, UI’s Rate Year capital plan does not exceed the 10-year inflation-adjusted (using GDP Deflator index) historical capital spend for reliability programs. Ex. UI-CIP-9, p. 10. UI’s Capital Plan breaks investments downPage 46 of 268
Connecticut Light and Power Company Docket No. 26-05-10 The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 31, 2026 OCC-507 Attachment 23 Page 46 of 268 OCC-507 CL&P Attachment 23 Docket No. 24-10-04 Page 46 of 268 Page 42 into eight major categories: capacity, customer, reliability, infrastructure replacement (substations and distribution system), resiliency, system operations, business effectiveness, and modernization. Ex. UI-CIP-7, p. 1. UI divides reliability programs into two main categories, as shown in Table 21, below: (1) baseline programs needed to maintain reliability (as measured by system SAIDI and SAIFI); and (2) incremental programs made to improve reliability performance. Ex. UI-CIP-9, p. 12. Table 21: UI Investment Categories Baseline Programs (Maintain Reliability) Modernization Business effectiveness Customer service technology Facilities Fleet Metering Compliance and safety Customer lighting State/municipal projects Third-party pole attachment make ready Infrastructure replacements Certain resilience programs Operations Capacity Incremental Programs (Improve Reliability) Corrective reliability (worst-performing circuits) Certain modernization like distributed automation “Other” system resilience projects Ex. UI-CIP-9, pp. 12, 14–15. The affordability analysis considers average 10-year capital spend of Baseline and Incremental program escalated by the GDP Deflator index to set the threshold. For purposes of the affordability analysis, UI excludes new customer connections and customer projects from baseline and incremental because they are exempt from the affordability analysis in the 17-12-03RE08 Decision. Ex. UI-CIP-9, p. 15. Those investments are not planned by UI to address system reliability or operational needs but are done to meet specific customer needs (e.g., new customer connections). 17-1203RE08 Decision, p. 46. The affordability analysis shows that the Rate Year capital plan falls within the affordability threshold. The affordability threshold of 10-year baseline and incremental programs using the GDP Deflator Index is $131.3 million ($176.4 million using Handy Whitman Index as a cost escalator). Ex. UI-CIP-9, p. 42; Interrog. Resp. OCC-374, Att. 1. UI’s proposed Rate Year baseline and incremental program capital expenditures are $121.0 million, which is under the threshold. Id. UI’s five-year capital plan (2024-2028) Incremental and Baseline program (excluding customer programs) forecasted CapEx isPage 47 of 268
Connecticut Light and Power Company Docket No. 26-05-10 The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 31, 2026 OCC-507 Attachment 23 Page 47 of 268 OCC-507 CL&P Attachment 23 Docket No. 24-10-04 Page 47 of 268 Page 43 $110.2 million, which is also under the threshold. UI does not propose an incremental reliability benefit with the Rate Year investments, instead settling on a maintenance of reliability performance, which is permitted in the Reliability Framework. See Ex. UI-CIP9, p. 10; Ex. UI-CIP-1, p. 46; 17-12-03RE08 Decision, p. 47. UI does propose a 5% reliability improvement for its five-year capital plan, which the Company claims is dependent upon PURA approving funding requested in the Application. UI-EOP-1, p. 18. Although UI’s affordability analysis in the application uses the GDP Deflator index to normalize costs, UI proposes that the Handy-Whitman (HW) Index is a better measure to reflect costs experienced by a utility over time. The choice of index does not have a material effect on this Application, as the proposed CapEx is under the affordability threshold using the GDP Deflator Index. However, the Authority notes that the HW Index is typically a better reflection of utility costs. The GDP deflator is a formula that measures the real value of the U.S. economy’s total output reduced by inflation over time and, therefore, measures the change in costs over time based on the entire U.S. economy and is reflective of how costs impact consumers. See Ex. UI-CIP-9, p. 35. The HandyWhitman Index reflects escalation of utility costs over time and has an index specific to northeast utilities (rather than the entire country, as the GDP Deflator Index reflects). Id. Specifically, the GDP Deflator Index considers economy-wide measures such as personal consumption expenditures, private domestic investment, exports of goods and services, and government expenditures and consumption. Ex. UI-CIP-9, p. 36. By contrast, the HW Index considers utility construction costs by FERC plant account (e.g., transformers, meters, overhead conductors, station equipment). Id. The HW Index better reflects costs of utilities doing business, while the GDP Deflator reflects costs from the consumer’s perspective. Cost escalation according to the HW Index has outpaced that of the GDP Inflator, particularly since 2021/2022. Ex. UI-CIP-9, p. 37. As of 2024, the GDP Deflatormeasured inflation was 5% since 2022 (13% since 2021) and the HW Index-measured inflation was 35% since 2022 (49% since 2021). Ex. UI-CIP-9, p. 37. Key contributors to the significant escalation rates of the HW Index since 2021 have been for major distribution equipment: transformers, overhead and underground conductors, and meters (though not as significant as the other contributors). See Interrog. Resp. OCC-374, Att. 1, p. 2. 3. Compliance with the Resilience Framework UI’s Resilience Plan complies with the Resilience Framework requirements established by the Authority on August 31, 2022. 17-12-03RE08 Decision, pp. 57-71. “[W]hen seeking approval for resilience program expenditures, each EDC must design and submit a [Resilience] plan in accordance with the Resilience Framework.” 17-1203RE08 Decision, p. 58. The Resilience Framework requires that UI identify “zones” of the system and prioritize them based primarily on historical SAIDI data as well as other data and criteria including: other outage-based data (SAIFI and CAIDI); system characteristics (feeder type, vegetation density, etc.); and community priorities (critical facilities, areas of distressed municipalities, etc.). 17-12-03RE08 Decision, p. 61. The Resilience Plans also must include methodology to determine how different resilience measures are evaluated and selected for each identified zone. Id., p. 62. TherePage 48 of 268
Connecticut Light and Power Company Docket No. 26-05-10 The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 31, 2026 OCC-507 Attachment 23 Page 48 of 268 OCC-507 CL&P Attachment 23 Docket No. 24-10-04 Page 48 of 268 Page 44 must be more than one mitigation measure evaluated for the selected zones. Id. The Resilience Plan must include 5-, 10-, 20-, and 30-year BCA’s, comparing the costs of the Resilience Plan against avoided interruption costs, avoided restoration costs, avoided VM costs, and avoided pole replacement costs. Id., pp. 64–65. UI selected nine circuits as priority zones using, primarily, system SAIDI and SAIFI, while also factoring in all the other criteria of the 17-12-03RE08 Decision. See Ex. UI-CIP-10, pp. 10 (specific weighting of criteria). UI analyzed different mitigation measures for those nine circuits ranging from least cost topology improvements like adding line reclosers, switches, and cutouts to higher costs of selective undergrounding and installation of aerial cable to highest costs of full undergrounding of each mainline. Ex. UI-CIP-10, pp. 11–12. From this analysis, UI established a five-year Resilience Plan, which made the most cost-beneficial resilience selections using the established BCA framework. See Ex. UI-CIP-10, pp. 20–26 (UI’s application of interruption cost estimate); Ex. UI-CIP-10, pp. 26–28 (storm occurrence estimation); Interrog. Resp. RSR-270, Att. 1 (analysis of how mitigation measures were selected for the nine zones). The final Resilience Plan includes investments totaling $24.47 million from 2026-2031. Ex. UI-CIP-10, p. 30. The resulting BCA considers two storm scenarios: scenario 1 is more conservative (using actual events 2019-2023 as a baseline, with one Isaias-level event in that time); and scenario 2 is more aggressive (an Isaias-level event occurs twice in the five-year period). Ex. UI-CIP-10, pp. 27–28. The BCA analysis provides a 30-year BCA of the Resilience Plan of 1.0 (break-even) under the storm 1 scenario and 1.57 under the storm 2 scenario. Ex. UI-CIP-10, p. 37. For benefit evaluation periods of less than 30 years, the BCAs were all less than 1. 4. Compliance with Climate Change and Vulnerability Study UI’s Climate Change and Vulnerability Study (CCVS) complies with the Authority’s requirements. See 17-12-03RE08 Decision, p. 80. The Climate Change and Vulnerability Study is required to include (1) a list of identified vulnerabilities, (2) proposals addressing vulnerabilities, and (3) long-term goals for addressing climate risk; all of which should inform the Reliability and Resilience Plans. 17-12-03RE08 Decision, p. 80. UI’s CCVS is comprehensive and includes identification of vulnerabilities, plans to address vulnerabilities (which include specific substation flood mitigation, updated construction standards, etc.), and the development of long-term goals for several different climate risks (extreme heat, flooding, etc.). See Ex. UI-CIP-11. 5. Five-Year Capital Plan UI proposed recovery in rates of plant additions through the end of the Rate Year. Table 22, below, shows plant additions requested in the Application. Table 22: Actual and Planned Plant Additions 9/1/22-12/31/22 100,635,703 Actual and Planned Plant Additions ($) 2023 2024 2025 159,985,638 101,556,138 77,171,756 Application, Ex. UI-CIP-3, Ex. UI-CIP-5. 2026 95,837,457
Text of OCC-507 Attachment 22.pdf
Extracted from the file · 178 pages · 528,336 characters
Text of OCC-507 Attachment 21.pdf
Extracted from the file · 296 pages · 1,013,669 characters
Text of OCC-507 Attachment 20.pdf
Extracted from the file · 167 pages · 508,170 characters
Text of OCC-507 Attachment 19.pdf
Extracted from the file · 137 pages · 450,996 characters
Text of OCC-507 Attachment 18.pdf
Extracted from the file · 247 pages · 763,200 characters
Text of OCC-507 Attachment 17.pdf
Extracted from the file · 2 pages · 6,387 characters
Text of OCC-507 Attachment 16.pdf
Extracted from the file · 2 pages · 484 characters
Text of OCC-507 Attachment 15.pdf
Extracted from the file · 202 pages · 895,816 characters
Text of OCC-507 Attachment 14.pdf
Extracted from the file · 6 pages · 8,947 characters
Text of OCC-507 Attachment 13.pdf
Extracted from the file · 19 pages · 93,122 characters
Text of OCC-507 Attachment 12.pdf
Extracted from the file · 19 pages · 95,631 characters
Text of OCC-507 Attachment 11.pdf
Extracted from the file · 7 pages · 10,667 characters
Text of OCC-507 Attachment 8.pdf
Extracted from the file · 2 pages · 3,673 characters
Text of OCC-507 Attachment 4.pdf
Extracted from the file · 6 pages · 8,272 characters
Text of OCC-507 Attachment 2.pdf
Extracted from the file · 8 pages · 30,345 characters
Text of OCC-507 Attachment 1.pdf
Extracted from the file · 32 pages · 164,962 characters
Text of OCC-507 Attachment 39.pdf
Extracted from the file · 22 pages · 32,510 characters
Text of OCC-507 Attachment 31.pdf
Extracted from the file · 8 pages · 37,747 characters
Text of OCC-507 Attachment 30.pdf
Extracted from the file · 5 pages · 22,063 characters
Text of OCC-507 Attachment 10.pdf
Extracted from the file · 3 pages · 4,485 characters
Text of OCC-507 Attachment 9.pdf
Extracted from the file · 10 pages · 15,175 characters
Text of OCC-507 Attachment 7.pdf
Extracted from the file · 3 pages · 5,747 characters
Text of OCC-507 Attachment 6.pdf
Extracted from the file · 4 pages · 6,545 characters
Text of OCC-507 Attachment 5.pdf
Extracted from the file · 4 pages · 5,724 characters
Text of OCC-507 Attachment 3.pdf
Extracted from the file · 65 pages · 195,008 characters
As listed on the current system
Question(s) Answered 507, 508, 509, 510, 511, 512, 517, 518 (The Connecticut Light and Power Company dba Eversource Energy) Date Filed: 09/14/2026