Interrogatory responses
Answers to questions 507, 508, 509, 510, 511, 512, 517, 518
Files53
OCC-507_Final.pdf
PDF · 195 KB · 6 pagesText searchable
Download OCC-507_Final.pdfRead the text of OCC-507_Final.pdf
OCC-508_Final.pdf
PDF · 81 KB · 1 pageText searchable
Download OCC-508_Final.pdfRead the text of OCC-508_Final.pdf
OCC-509_Final.pdf
PDF · 86 KB · 1 pageText searchable
Download OCC-509_Final.pdfRead the text of OCC-509_Final.pdf
OCC-510_Final.pdf
PDF · 190 KB · 3 pagesText searchable
Download OCC-510_Final.pdfRead the text of OCC-510_Final.pdf
OCC-511_Final.pdf
PDF · 215 KB · 8 pagesText searchable
Download OCC-511_Final.pdfRead the text of OCC-511_Final.pdf
OCC-512_Final.pdf
PDF · 82 KB · 1 pageText searchable
Download OCC-512_Final.pdfRead the text of OCC-512_Final.pdf
OCC-517_Final.pdf
PDF · 131 KB · 1 pageText searchable
Download OCC-517_Final.pdfRead the text of OCC-517_Final.pdf
OCC-518_Final.pdf
PDF · 81 KB · 1 pageText searchable
Download OCC-518_Final.pdfRead the text of OCC-518_Final.pdf
OCC-512 Attachment 3 REDACTED.pdf
PDF · 5.2 MB · 33 pagesText searchable
Download OCC-512 Attachment 3 REDACTED.pdfRead the text of OCC-512 Attachment 3 REDACTED.pdf
OCC-512 Attachment 2 REDACTED.pdf
PDF · 6.8 MB · 33 pagesText searchable
Download OCC-512 Attachment 2 REDACTED.pdfRead the text of OCC-512 Attachment 2 REDACTED.pdf
OCC-512 Attachment 1.pdf
PDF · 23 MB · 626 pagesText searchable
Download OCC-512 Attachment 1.pdfRead the text of OCC-512 Attachment 1.pdf
OCC-507 Attachment 42.pdf
PDF · 1.7 MB · 3 pagesText searchable
Download OCC-507 Attachment 42.pdfRead the text of OCC-507 Attachment 42.pdf
OCC-507 Attachment 41.pdf
PDF · 1.8 MB · 9 pagesText searchable
Download OCC-507 Attachment 41.pdfRead the text of OCC-507 Attachment 41.pdf
OCC-507 Attachment 40.pdf
PDF · 2.2 MB · 5 pagesText searchable
Download OCC-507 Attachment 40.pdfRead the text of OCC-507 Attachment 40.pdf
OCC-507 Attachment 38.pdf
PDF · 4.6 MB · 19 pagesText searchable
Download OCC-507 Attachment 38.pdfRead the text of OCC-507 Attachment 38.pdf
OCC-507 Attachment 37.pdf
PDF · 2.9 MB · 49 pagesText searchable
Download OCC-507 Attachment 37.pdfRead the text of OCC-507 Attachment 37.pdf
OCC-507 Attachment 36.pdf
PDF · 2.9 MB · 59 pagesText searchable
Download OCC-507 Attachment 36.pdfRead the text of OCC-507 Attachment 36.pdf
OCC-507 Attachment 35.pdf
PDF · 4.3 MB · 38 pagesText searchable
Download OCC-507 Attachment 35.pdfRead the text of OCC-507 Attachment 35.pdf
OCC-507 Attachment 34.pdf
PDF · 2.1 MB · 5 pagesText searchable
Download OCC-507 Attachment 34.pdfRead the text of OCC-507 Attachment 34.pdf
OCC-507 Attachment 33.pdf
PDF · 2.9 MB · 13 pagesText searchable
Download OCC-507 Attachment 33.pdfRead the text of OCC-507 Attachment 33.pdf
OCC-507 Attachment 32.pdf
PDF · 1.6 MB · 5 pagesText searchable
Download OCC-507 Attachment 32.pdfRead the text of OCC-507 Attachment 32.pdf
OCC-507 Attachment 29.pdf
PDF · 1.8 MB · 8 pagesText searchable
Download OCC-507 Attachment 29.pdfRead the text of OCC-507 Attachment 29.pdf
OCC-507 Attachment 28.pdf
PDF · 2.5 MB · 18 pagesText searchable
Download OCC-507 Attachment 28.pdfRead the text of OCC-507 Attachment 28.pdf
OCC-507 Attachment 27.pdf
PDF · 3.0 MB · 35 pagesText searchable
Download OCC-507 Attachment 27.pdfRead the text of OCC-507 Attachment 27.pdf
OCC-507 Attachment 26.pdf
PDF · 5.0 MB · 19 pagesText searchable
Download OCC-507 Attachment 26.pdfRead the text of OCC-507 Attachment 26.pdf
OCC-507 Attachment 25.pdf
PDF · 2.0 MB · 12 pagesText searchable
Download OCC-507 Attachment 25.pdfRead the text of OCC-507 Attachment 25.pdf
OCC-507 Attachment 24.pdf
PDF · 1.5 MB · 2 pagesText searchable
Download OCC-507 Attachment 24.pdfRead the text of OCC-507 Attachment 24.pdf
OCC-507 Attachment 23.pdf
PDF · 21 MB · 268 pagesText searchable
Download OCC-507 Attachment 23.pdfRead the text of OCC-507 Attachment 23.pdf
OCC-507 Attachment 22.pdf
PDF · 25 MB · 178 pagesText searchable
Download OCC-507 Attachment 22.pdfRead the text of OCC-507 Attachment 22.pdf
OCC-507 Attachment 21.pdf
PDF · 38 MB · 296 pagesText searchable
Download OCC-507 Attachment 21.pdfRead the text of OCC-507 Attachment 21.pdf
OCC-507 Attachment 20.pdf
PDF · 22 MB · 167 pagesText searchable
Download OCC-507 Attachment 20.pdfRead the text of OCC-507 Attachment 20.pdf
OCC-507 Attachment 19.pdf
PDF · 9.1 MB · 137 pagesText searchable
Download OCC-507 Attachment 19.pdfRead the text of OCC-507 Attachment 19.pdf
OCC-507 Attachment 18.pdf
PDF · 17 MB · 247 pagesText searchable
Download OCC-507 Attachment 18.pdfRead the text of OCC-507 Attachment 18.pdf
OCC-507 Attachment 17.pdf
PDF · 1.4 MB · 2 pagesText searchable
Download OCC-507 Attachment 17.pdfRead the text of OCC-507 Attachment 17.pdf
OCC-507 Attachment 16.pdf
PDF · 1.4 MB · 2 pagesText searchable
Download OCC-507 Attachment 16.pdfRead the text of OCC-507 Attachment 16.pdf
OCC-507 Attachment 15.pdf
PDF · 32 MB · 202 pagesText searchable
Download OCC-507 Attachment 15.pdfRead the text of OCC-507 Attachment 15.pdf
OCC-507 Attachment 14.pdf
PDF · 2.6 MB · 6 pagesText searchable
Download OCC-507 Attachment 14.pdfRead the text of OCC-507 Attachment 14.pdf
OCC-507 Attachment 13.pdf
PDF · 4.8 MB · 19 pagesText searchable
Download OCC-507 Attachment 13.pdfRead the text of OCC-507 Attachment 13.pdf
OCC-507 Attachment 12.pdf
PDF · 4.6 MB · 19 pagesText searchable
Download OCC-507 Attachment 12.pdfRead the text of OCC-507 Attachment 12.pdf
OCC-507 Attachment 11.pdf
PDF · 4.9 MB · 7 pagesText searchable
Download OCC-507 Attachment 11.pdfRead the text of OCC-507 Attachment 11.pdf
OCC-507 Attachment 8.pdf
PDF · 1.4 MB · 2 pagesText searchable
Download OCC-507 Attachment 8.pdfRead the text of OCC-507 Attachment 8.pdf
OCC-507 Attachment 4.pdf
PDF · 2.6 MB · 6 pagesText searchable
Download OCC-507 Attachment 4.pdfRead the text of OCC-507 Attachment 4.pdf
OCC-507 Attachment 2.pdf
PDF · 2.2 MB · 8 pagesText searchable
Download OCC-507 Attachment 2.pdfRead the text of OCC-507 Attachment 2.pdf
OCC-507 Attachment 1.pdf
PDF · 3.5 MB · 32 pagesText searchable
Download OCC-507 Attachment 1.pdfRead the text of OCC-507 Attachment 1.pdf
OCC-507 Attachment 39.pdf
PDF · 1.5 MB · 22 pagesText searchable
Download OCC-507 Attachment 39.pdfRead the text of OCC-507 Attachment 39.pdf
OCC-507 Attachment 31.pdf
PDF · 1.8 MB · 8 pagesText searchable
Download OCC-507 Attachment 31.pdfRead the text of OCC-507 Attachment 31.pdf
OCC-507 Attachment 30.pdf
PDF · 1.9 MB · 5 pagesText searchable
Download OCC-507 Attachment 30.pdfRead the text of OCC-507 Attachment 30.pdf
OCC-507 Attachment 10.pdf
PDF · 1.6 MB · 3 pagesText searchable
Download OCC-507 Attachment 10.pdfRead the text of OCC-507 Attachment 10.pdf
OCC-507 Attachment 9.pdf
PDF · 6.2 MB · 10 pagesText searchable
Download OCC-507 Attachment 9.pdfRead the text of OCC-507 Attachment 9.pdf
OCC-507 Attachment 7.pdf
PDF · 1.5 MB · 3 pagesText searchable
Download OCC-507 Attachment 7.pdfRead the text of OCC-507 Attachment 7.pdf
OCC-507 Attachment 6.pdf
PDF · 1.5 MB · 4 pagesText searchable
Download OCC-507 Attachment 6.pdfRead the text of OCC-507 Attachment 6.pdf
OCC-507 Attachment 5.pdf
PDF · 1.5 MB · 4 pagesText searchable
Download OCC-507 Attachment 5.pdfRead the text of OCC-507 Attachment 5.pdf
OCC-507 Attachment 3.pdf
PDF · 5.4 MB · 65 pagesText searchable
Download OCC-507 Attachment 3.pdfRead the text of OCC-507 Attachment 3.pdf
Text of OCC-510_Final.pdf
Extracted from the file · 3 pages · 6,553 characters
Text of OCC-511_Final.pdf
Extracted from the file · 8 pages · 17,894 characters
Text of OCC-512_Final.pdf
Extracted from the file · 1 page · 992 characters
Text of OCC-517_Final.pdf
Extracted from the file · 1 page · 826 characters
Text of OCC-518_Final.pdf
Extracted from the file · 1 page · 601 characters
Text of OCC-512 Attachment 3 REDACTED.pdf
Extracted from the file · 33 pages · 5,436 characters
Text of OCC-512 Attachment 2 REDACTED.pdf
Extracted from the file · 33 pages · 5,436 characters
Text of OCC-512 Attachment 1.pdf
Extracted from the file · 626 pages · 635,148 characters
Text of OCC-507 Attachment 42.pdf
Extracted from the file · 3 pages · 10,259 characters
Text of OCC-507 Attachment 41.pdf
Extracted from the file · 9 pages · 3,276 characters
Text of OCC-507 Attachment 40.pdf
Extracted from the file · 5 pages · 8,775 characters
Text of OCC-507 Attachment 38.pdf
Extracted from the file · 19 pages · 96,311 characters
Text of OCC-507 Attachment 37.pdf
Extracted from the file · 49 pages · 120,692 characters
Text of OCC-507 Attachment 36.pdf
Extracted from the file · 59 pages · 136,630 characters
Text of OCC-507 Attachment 35.pdf
Extracted from the file · 38 pages · 102,807 characters
Text of OCC-507 Attachment 34.pdf
Extracted from the file · 5 pages · 1,210 characters
Text of OCC-507 Attachment 33.pdf
Extracted from the file · 13 pages · 52,489 characters
Text of OCC-507 Attachment 32.pdf
Extracted from the file · 5 pages · 14,030 characters
Text of OCC-507 Attachment 29.pdf
Extracted from the file · 8 pages · 37,747 characters
Text of OCC-507 Attachment 28.pdf
Extracted from the file · 18 pages · 75,925 characters
Text of OCC-507 Attachment 27.pdf
Extracted from the file · 35 pages · 66,295 characters
Text of OCC-507 Attachment 26.pdf
Extracted from the file · 19 pages · 68,589 characters
Text of OCC-507 Attachment 25.pdf
Extracted from the file · 12 pages · 53,851 characters
Text of OCC-507 Attachment 24.pdf
Extracted from the file · 2 pages · 482 characters
Text of OCC-507 Attachment 23.pdf
Extracted from the file · 268 pages · 869,686 characters
Text of OCC-507 Attachment 22.pdf
Extracted from the file · 178 pages · 528,336 characters
Page 157 of 296
Connecticut Light and Power Company Docket No. 26-05-10 Docket No. 22-08-08 The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 31, 2026 OCC-507 Attachment 21 Page 157 of 296 OCC-507 CL&P Attachment 21 Page 157 of 296 Page 151 often needs to make decisions well before it is known whether storms will materialize or not. Id. Making decisions early is especially necessary for storms that track the eastern seaboard, since UI will have to compete with other utilities who are either securing outside resources themselves or are hesitant to release crews. Id. UI states that the increase in the storm reserve allowance will help it secure sufficient resources far enough in advance. Id. The Company also asserts that there have been an increasing number, severity, and costs of storms in recent years, which justifies an increase to the accrual. Id., p. 19. The Company also asserts the need to increase the frequency of leaning-in activities to avoid reimbursing customers for long duration outages pursuant to Conn. Gen. Stat. § 16-32m. Id., p. 21. Regarding the Company’s assertion that there are more frequent storms requiring the Company to incur more leaning in costs and more restoration costs, the evidence suggests otherwise. From 2013-2015, the first three years following the initiation of the $2 million per year storm reserve, UI charged no storms to the storm reserve. Interrog. Resp. OCC-159. In 2016, UI only charged lean-in costs for one event that did not otherwise qualify for the reserve. Id., Att. 1. From 2017 through 2022, UI charged 11 events to the storm reserve. Id. During the 2016 Rate Case, the Authority declined to eliminate the storm reserve accrual despite no storms being charged and a reserve balance of $6.763 million that had accumulated during those quiet years. 2016 Rate Case Decision, p. 111. The Authority finds itself in a situation similar to the previous rate case. As it did in 2016, the Authority declines to hastily modify the storm reserve accrual here. Regarding UI’s claim that since reserve storm costs are increasing, the accrual should likewise increase, again the Authority finds the opposite. The requested storm regulatory asset balance in 2013 ($53 million) was more than two times larger than the balance presented in this case ($25.7 million). Sch. B-1.0; 2013 Rate Case Decision, p. 24. Prior to 2013, there was no accrual, and it was only during the 2013 Rate Case that UI requested and received a $2 million accrual. Id. This level was deemed sufficient at the time and remains sufficient now given insufficient evidence to the contrary. Id. In short, circumstances have not changed to warrant an increase in storm reserve accrual. Furthermore, the Authority finds the Company’s argument that it needs to increase the accrual due to lean-in costs unsupported by the record. There is nothing in the record to suggest that the current storm reserve accrual has been inadequate to support UI’s ability to lean-in. Further, the Authority cannot evaluate UI’s lean-in costs in detail because UI does not separate lean-in costs from storm recovery costs when a major storm occurs, so the Authority has no way to evaluate the level of lean-in costs. Interrog. Resp. RSR-68. The primary purpose of the Storm Reserve has always been to help mitigate rate shocks that are often associated with the accrual of significant storm recovery costs. 2016 Rate Case Decision, p. 111. The storm reserve accrual is also useful to the extent it encourages UI to prepare for potential storms by leaning-in. Id. The Authority finds that the current accrual level continues to serve both purposes adequately.Page 158 of 296
Connecticut Light and Power Company Docket No. 26-05-10 The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 31, 2026 OCC-507 Attachment 21 Page 158 of 296 OCC-507 CL&P Attachment 21 Docket No. 22-08-08 Page 158 of 296 Page 152 Accordingly, the Authority denies UI’s request to increase the accrual by $1 million. This adjustment decreases UI’s Outside Services – Storm Reserve account expense by $1 million. Sch. C-3.06. b. Increase Threshold Value for Major Storm The Authority increases the threshold by which the Company can charge storm costs to the storm reserve account to recognize the Company’s increased operating costs. Currently, the Company is allowed to charge storm expenses to the storm reserve if the incremental expense for an event is at least $1 million (major storm threshold). 2013 Rate Case Decision, p. 30. The purpose of the threshold is to distinguish between storms that should be considered a normal part of business operations and catastrophic storms. Id., p. 29. Only catastrophic storms are appropriate for special regulatory treatment (i.e., accounting deferral) to protect the Company against events that require the Company to pay out large sums of money that are not immediately available from customers. Id., p. 28. The Authority determined that a $1 million threshold was appropriate in 2013. Id., p. 30. This threshold has not changed since 2013, but utility construction costs have escalated since that time. Interrog. Resp. RSR-88. Not reflecting these changes in construction and operating costs in the major storm threshold tips the delicate balance of a storm reserve against the customers. The Handy-Whitman Index is an industry-standard index used to reflect prior utility construction costs in current dollars and is appropriate to both capital projects and O&M costs, such as those costs incurred during storms. Hr’g Tr., 1086:1-13, 838:9-14. The Handy-Whitman Index is updated biannually (on July 1 and January 1) and has an index specific to North Atlantic utilities. Interrog. Resp. RSR-88, Att. 1. To ensure the major storm threshold remains reflective of actual utility costs and captures only catastrophic storms, the Authority will increase the major storm threshold by using the Handy-Whitman Index for utilities in the North Atlantic region to convert July 1, 2013 dollars to July 1, 2022 dollars. Id. Using the “Distribution Plant” category in the index gives an escalation factor of 1.43. Id., Att. 1. Applying the escalation factor to the $1 million threshold yields $1.43 million. UI argues that changing the major storm threshold requires adding operating expenses to offset the costs of storms that no longer qualify for the major storm threshold. UI Exceptions, p. 113. UI states that it has not had an opportunity to identify such costs to enable fair recovery of them. Id. To determine the incremental expenses that UI may incur when the major storm threshold is increased, the Authority looked at the storms that qualified for the storm reserve since 2013 Rate Case Decision, and applied the HandyWhitman Index to those storms to assess whether its application would have triggered the eligibility threshold for the storm reserve. Had the Handy-Whitman Index been used to update the major storm threshold since 2014, only three of the twelve events recorded to the storm reserve since 2014 would not have qualified for the storm reserve. These three events are:Page 159 of 296
Connecticut Light and Power Company Docket No. 26-05-10 The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 31, 2026 OCC-507 Attachment 21 Page 159 of 296 OCC-507 CL&P Attachment 21 Docket No. 22-08-08 Page 159 of 296 Page 153 1. July 8, 2021 storm (Elsa) with incremental cost of $1.076 million; 2. January 17, 2022 storm (Izzy) with incremental cost of $1.097 million; and 3. January 29, 2022 storm (blizzard) with incremental cost of 1.345 million. Interrog. Resp. OCC-77, Att. 1; Interrog. Resp. RSR-88, Att. 1. Had these storms been excluded from recovery from the storm reserve, the Company would have incurred a sum total of $3.518 million in expenses over a nine and a half year period (from January 2014 through July 2022), for an average annual expense of $370,316. Ex. UI-EPP-3. However, a portion of these costs were for lean-in (or storm preparation) costs. Interrog. Resp. RSR-68, Att. 1. Lean-in costs are allowable for assignment to the storm reserve regardless of whether the incremental storm costs meet the major storm threshold. 2016 Rate Case Decision, p. 110; Hr’g Tr., 1216:23-25. Although UI has a responsibility to provide lean-in costs for auditing, 2016 Rate Case Decision, p. 110, the Company failed to separately track or present lean-in costs for any of the events; therefore, the Authority is unable to determine how much of the $3.518 million would have been applied to the storm reserve regardless of whether the total storm costs met the threshold. Interrog. Resp. RSR-68, Att. 1; Hr’g Tr., 2005:15-2006:17. Nor did the Company provide the number of external line resources that were secured prior to the events. Interrog. Resp. RSR-68. Nevertheless, the Authority has reason to believe a substantial portion of the total storm costs are attributable to lean-in costs because (1) the Company secures resources to be on-site prior to events to comply with its emergency response plan and has increased its reliance on this policy following lessons learned from Tropical Storm Isaias, and (2) external resource costs are a large portion of total incremental storm expenses. Interrog. Resp. OCC-77, Att. 1; Hr’g Tr., 1217:2-15; EPP PFT, p. 21. As such, the available evidence indicates that the Company would not incur significant incremental operating expenses as a result of the change to the major storm threshold. The Authority will determine at a future rate proceeding whether an increase to operating expense is needed as an offset to increased major storm threshold when UI can provide the data to justify an offset. Such a plan is consistent with what the Authority did in the 2013 Rate Case Decision, when the major storm threshold of $1 million was first established.124 2013 Rate Case Decision, p. 28. Accordingly, the Authority sets the new major storm threshold for charging storms to the reserve at $1.43 million. The Authority directs UI to apply the Handy-Whitman index on an ongoing basis with each biannual release of the index on January 1 and July 1, and to update its major storm threshold each January 1 and July 1 accordingly. The Authority directs UI to retain documentation demonstrating it applied the Handy-Whitman Index when it next requests recovery of major storm costs in the storm reserve. 124 When faced with the same argument, the Authority found that “there is no evidence presented indicating the extent to which the storm reserve is either consistent or inconsistent with any O&M level, or what that O&M level might be. As a result, the Authority is limited to defining major storms on a basis consistent with catastrophic events. Meanwhile, the degree to which this definition makes storm-related O&M expenses now in rates too high, too low or just right will have to be decided in a future proceeding.” 2013 Rate Case Decision, p. 28.Page 160 of 296
Connecticut Light and Power Company Docket No. 26-05-10 The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 31, 2026 OCC-507 Attachment 21 Page 160 of 296 OCC-507 CL&P Attachment 21 Docket No. 22-08-08 Page 160 of 296 Page 154 c. Logistics Vendor Costs in Storm Reserve The Company seeks to enter into an agreement for $120,000 annually with a logistics vendor specializing in securing lodging to assist with storm preparation. EPP PFT, p. 22. The Company offers to charge the costs to the storm reserve. Id., p. 23. The Company claims that the benefits of such an agreement will take advantage of the vendor’s expertise to find cost-effective lodging for external crews, while freeing up Company personnel (who are not experts in securing lodging) to focus on other logistics concerns. Id., pp. 22-23. UI expects that such an agreement would result in shorter travel times for crews and more and better lodging options. Id., p. 23. The Company determined the costs of the proposed agreement based on the experience of Avangrid affiliates who utilize similar agreements in the pilot program, but UI does not have formal quotes from vendors. Interrog. Resp. OCC-286. UI’s affiliates in New York have piloted the approach with a vendor from March 2021 through December 2023. Interrog. Resp. RSR-87. The Authority finds no compelling reason to approve the project. At best, the project is premature; there are no actual vendor quotes, and the benefits appear theoretical. UI provided no results from its affiliate’s pilot program. Interrog. Resp. RSR87. Lastly, and unrelated to the agreement itself, it is inappropriate to charge known and foreseeable expenses to the storm reserve. Doing so would be an abuse of the reserve. That said, the Authority is not opposed to UI using a vendor specializing in lodging. It may enter into such an agreement, but if it does so, such an agreement will have to be within the allowed expenses. The Authority will not authorize incremental ratepayer funds for such a project, particularly based on the unsubstantiated request made here. d. Mutual Aid Revenue The Company at times provides crews to other utilities (affiliate and otherwise unrelated) as mutual aid to assist in emergency storm restoration to affiliate and unrelated utility companies. Interrog. Resp. to OCC-546. The Company receives revenue for loaned crews, and the amount of revenue exactly offsets the incurred expenses resulting in a net impact of zero. Interrog. Resp. RSR-091. There is a timing difference between when the costs are incurred and when the Company receives the reimbursement, so the Company does not forecast these costs and revenues in the revenue requirement. Sch. WP C-3.28; Interrog. Resp. OCC-546. While it may be true that there is a net zero revenue impact from the Company’s perspective, it does not follow that this arrangement is entirely fair to customers. When an employee is released for mutual aid to other utilities they are, obviously, not available to do work for UI customers. One of two things happens, since the work they would normally perform still needs to be completed: (1) either the work is delayed; or (2) the Company uses contractors or internal employee overtime to complete the work. Interrog. Resp. RSR-91, p. 2; Hr’g Tr., 1265:17-25. In the case where the work is delayed, UI customers are paying UI employees to perform work elsewhere since UI is not forecasting mutual aid revenue in revenue requirements. This cost is not de minimis, as the table below demonstrates. The table shows UI’s total percentage of payroll that wasPage 161 of 296
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 31, 2026 OCC-507 Attachment 21 Page 161 of 296 Connecticut Light and Power Company Docket No. 26-05-10 OCC-507 CL&P Attachment 21 Docket No. 22-08-08 Page 161 of 296 Page 155 spent by employees in other jurisdictions by year. If, however, in this scenario ratepayers’ expenses were offset by the mutual aid revenue, UI ratepayers would not be harmed by the project delays. Table 54: Time Spent Away as a Percentage of Total Labor Mutual Aid Percentage of Gross Labor 2017 2018 2019 2020 2021 2022 n/a n/a 2.3% 4.3% 0.8% 2.2% Interrog. Resp. RSR-91, p. 2. In the case where work is completed with employee overtime or contract crews, UI customers are paying higher costs for the same work. Hr’g Tr., 1267:11-14. The following table compares the costs of internal employee standard pay, internal employee overtime pay, and contractor pay for all the work hours that employees were away on mutual aid to other utilities. Table 55: Estimated Costs for Employees Working at Other Utilities 2019 2020 2021 2022 Total Estimated Cost Internal – Standard $ 1.846 $ 1.925 $ 0.713 $ 1.496 Total Estimated Cost Internal – Overtime $ 2.342 $ 2.345 $ 0.990 $ 1.934 Total Estimated Cost – Contractor $ 3.735 $ 3.895 $ 1.299 $ 2.381 Interrog. Resp. RSR-91; Late Filed Ex. 41. The above table demonstrates that if work is performed by contractors or with internal employee overtime, then UI is incurring more costs to complete the work when employees are supporting other utilities through mutual aid. However, as the Company’s revenue is fixed, the increased crew cost is only relevant to ratepayers insofar as it reduces the amount of mutual aid revenue due to them. While the Authority is concerned that mutual aid revenue used to pay for more expense crews to do the same work incentivizes inefficient resource allocation, the Authority appreciates the reciprocal nature of mutual aid and defers to the Company’s judgement as to when the work warrants prioritization such that replacement crews at higher costs are brought in to complete the work. Ultimately, in either case, UI customers are paying for employees to work outside of UI’s service territory on non-UI projects. As such, the net revenue received by UI for this practice needs to be returned to customers. Accordingly, the Authority directs UI to record all net mutual aid revenue in the storm reserve as an additional accrual to the storm reserve. The Authority defines net mutual aid revenue as those revenues in excess of the costs of replacement crews to perform the work planned to be completed by the crew during their absence, to the extent such crews are retained, and any incremental costs incurred to send the crews to another utility for a given storm event. The Company shall not accrue net negative mutual aid revenues associated with a storm event to the storm reserve, nor seek recovery of such net negative revenues.Page 162 of 296
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 31, 2026 OCC-507 Attachment 21 Page 162 of 296 Connecticut Light and Power Company Docket No. 26-05-10 OCC-507 CL&P Attachment 21 Docket No. 22-08-08 Page 162 of 296 Page 156 12. Professional Services Expense a. CLEAN EARTH Initiative The Company proposed the creation of the CLEAN EARTH Initiative in its Application. The CLEAN EARTH Initiative would be located in The University of Connecticut’s (UConn) Technology Park where it could collaborate with the Eversource Energy Center. Id. The Company proposes six key research areas for the CLEAN EARTH Initiative including: (1) Climate Change Impact Modeling; (2) Outage and Flooding Forecasting; (3) Transmission and Distribution Planning; (4) DER Adoption Analysis and Strategy; (5) Clean Hydrogen and Offshore Wind Integrations; and (6) Stateof-the-Art Weather and Climate Information. Ex. UI-JA-1, pp. 10-12. The CLEAN EARTH Initiative would be overseen by an executive committee including: the Principal Investigator (PI); the Dean of the School of Engineering; the Provost (or their designee); the Vice President of Research (or their designee); and a maximum of three Avangrid appointees. The executive committee would determine the overall strategic direction of the CLEAN EARTH Initiative. Avangrid and UConn members of the executive committee would each have one vote. All matters before the executive committee would be decided by consensus. Ex. UI-JA-2, p. 3. The proposed total annual cost of the CLEAN EARTH Initiative is $423,000 for five years, which amounts to a total of $2.115 million. Interrog. Resp. CAE-15. The costs of the CLEAN EARTH Initiative include annual research and development costs of $250,000, which amounts to $1.25 million over five years, and annual program management costs of $173,000, which amounts to $865,000 over five years. Id. The research and development costs would be supported by a 90% / 10% cost share between UI customers and Avangrid, respectively. Id. This cost share proposal results in an annual expense charge to UI customers of $225,000 (.90 x $250,000 = $225,000). The program costs do not reflect receipt of any grants and UI states that any grant funding received in the projected rate years would be in addition to, and not a substitute for, the funding reflected in the Company’s proposed revenue requirement. Interrog. Resp. OCC226. The table summarizes the funding needs and sources to support the CLEAN EARTH Lab Initiative. Table 56: Funding for the CLEAN Earth Lab Initiatives Annual Amount Total (Five Years) Research & Development (90% R&D cost share) $225,000 $1,125,000 Customer-funded Research & Development (10% R&D cost share) $25,000 $125,000 Company-funded R&D SUBTOTAL 1 FTE (Program Manager) TOTAL $250,000 $173,000 $423,000 $1,250,000 $865,000 Customer-funded $2,115,000 Interrog. Resp. CAE-15, with corrected FTE and total costs.Page 163 of 296
Connecticut Light and Power Company Docket No. 26-05-10 Docket No. 22-08-08 The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 31, 2026 OCC-507 Attachment 21 Page 163 of 296 OCC-507 CL&P Attachment 21 Page 163 of 296 Page 157 The Authority applauds the Company’s proactive approach in developing the CLEAN EARTH Initiative and strongly supports the intention of the initiative and, specifically, the need for and potential benefits of fundamental research proposed. However, the Authority has several concerns with the proposed CLEAN EARTH Initiative as currently proposed. First, in applying traditional standards for cost recovery, the proposal is premature in its request as it lacks sufficient detail to approve full cost recovery from UI ratepayers. Second, the proposed governance structure is inadequate to ensure that the selected research projects will benefit the UI ratepayers who will be paying for the initiative. Third, although UI ratepayers will pay for the overwhelming majority of the costs of the initiative, Avangrid shareholders and affiliates will benefit from the insights and tools that result. Fourth, the Company has not adequately demonstrated a need for the program manager despite program management and FTE costs comprising nearly 40% of the total proposed costs. Lastly, the incremental value to Connecticut ratepayers of the CLEAN EARTH Initiative is unclear. The CLEAN EARTH Initiative proposal’s lack of sufficient details is evidenced by the fact that the Company identified broad research areas, but no specific projects, deliverables, or timelines. Hr’g Tr. Mar. 7, 2023, 2648: 22-24, 2668:13. The lack of concrete details regarding the research is in contrast with other research and development initiatives Avangrid is undertaking with the support of grant funding. For example, the $600,000 in grant funding Avangrid obtained through New York State’s Energy Research and Development Authority’s (NYSERDA) Program Opportunity Notice (PON) 4074: Electric Power Transmission and Distribution High Performing Grid required a cost schedule, an execution schedule, and a commercialization plan. Ex. UI-JA-1, p. 9; Hr’g Tr., Mar. 7, 2023, 2682: 2-4. Regarding the proposal’s governance structure, as the CLEAN EARTH Initiative is not fully defined, there is a risk that the selected research topics will primarily benefit Avangrid as opposed to UI ratepayers. Specifically, while some of the proposed key research areas, such as Outage and Flooding Forecasting, Climate Change Impact Modeling, and DER Adoption Analysis and Strategy, as defined, have clear potential benefits to UI’s distribution customers; other proposed key research areas, such as Transmission and Distribution Planning, Clean Hydrogen and Offshore Wind Integrations, and State-of-the-Art Weather and Climate Information, are more nebulous in how much, if at all, they will directly benefit distribution ratepayers, particularly depending on how the executive committee decides to direct such research areas (e.g., more of a focus on transmission than distribution planning). Also, notably, there is no stakeholder participation in the executive committee’s decision-making process. While the Company has indicated that it is not opposed to appointing a member of the Authority to the Committee, this position is not an adequate substitute for the stakeholder engagement that occurs in a docketed proceeding or other public process. Interrog. Resp. CAE-15. Further, the record is contradictory on which entity would have majority control of the committee’s decision-making. While the Master Research Agreement (MRA) indicates the committee would be composed of four officials from UConn and a maximum of three Avangrid appointees, the Company witness stated that UI would have a majority influence on the committee. Ex. UI-JA-2, p. 3; Hr’g Tr. Mar. 8, 2023, 2858:14. Relatedly, although the risks and costs of the investment are borne almost exclusively by UI ratepayers (the Avangrid cost share amounts to only 5.91% of the totalPage 164 of 296
Connecticut Light and Power Company Docket No. 26-05-10 Docket No. 22-08-08 The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 31, 2026 OCC-507 Attachment 21 Page 164 of 296 OCC-507 CL&P Attachment 21 Page 164 of 296 Page 158 proposed program cost), Avangrid shareholders and other Avangrid affiliates would benefit from the results of the research. For example, one proposed key research area is Clean Hydrogen and Offshore Wind Integration. Ex. UI-JA-1, p. 12. One of Avangrid’s two primary lines of business is Avangrid Renewables, which owns and operates a portfolio of renewable energy generation facilities across the United States. The Company specifically mentions Park City Wind (expected 804MW to Connecticut), Commonwealth Wind (expected 1,232MW to Massachusetts), and half of the Vineyard Wind 1 project (800MW to Massachusetts). Ex. UI-JA-2, pp. 1-2. The Authority notes that of the 2,836 MW of planned offshore wind generation described in the MRA, 72% would serve customers in Massachusetts. There is no offshore wind currently connected to Connecticut’s distribution system, and none of the 2.4 GW of offshore wind Avangrid has contracted is operational today. Hr’g Tr. Mar. 7, 2023, 2666:3-4, 2667:4-6. In short, the tangible benefits to UI ratepayers are tenuous, but the benefits to Avangrid and its renewable generation business are apparent. Indeed, conducting fundamental research to understand what level of curtailment offshore wind resources will experience or whether assets should be optimized for output capacity, cost, or time of availability is far more relevant to the economic operation of offshore wind and hydrogen generation assets, which would ultimately generate revenue for Avangrid Renewables. Interrog. Resp. RSR-103. This line of research would also distort competition by allowing Avangrid to subsidize its competitive business ventures with funds from its monopoly business ventures. Insights into offshore wind and hydrogen integration could inform Avangrid Renewable’s early-stage investments in hydrogen technologies and inform the Company on optimal operational strategies, which may give the Company an advantage over generation companies that cannot conduct fundamental research using funds from captive customers. In addition to Avangrid Renewables, other Avangrid affiliates would benefit from the results of the CLEAN EARTH Lab initiative as well. As proposed, the initiative would be conducted on an Avangrid-wide level. Notably, the MRA states that the executive committee will include Avangrid appointees rather than UI appointees. Ex. UI-JA-2, p. 3. The subject matter experts (SME) who would play a key role in determining the scope of the research work with other Avangrid affiliates. Ex. UI-CETP-1, pp. 1-3. Consequently, the insights and tools that would result from the research would provide a direct benefit to those affiliates. Another primary area of concern regarding the CLEAN EARTH Lab initiative is that a significant portion (40%) of funding needed for program management requires an additional FTE as proposed by the Company, which the Company has not adequately justified in its Application. The MRA states that the initiative will be led by a UConn PI and overseen by the executive committee. Ex. UI-JA-2, p. 3. There is no mention of the program manager in the MRA. Further, it is not clear that the responsibilities outlined in Ex. UI-JA-5 would be so extensive as to warrant an additional FTE. For instance, the need to “[w]ork with UI SMEs…to identify topics and areas to apply innovative research” would seem unnecessary given that the key research areas are already outlined in Ex. UI-JA-1. Ex. UI-JA-5, p. 2. The Authority recognizes that more granular research topics would be developed once the CLEAN EARTH Initiative was launched, but it is not clearPage 165 of 296
Connecticut Light and Power Company Docket No. 26-05-10 Docket No. 22-08-08 The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 31, 2026 OCC-507 Attachment 21 Page 165 of 296 OCC-507 CL&P Attachment 21 Page 165 of 296 Page 159 that UI SMEs, in collaboration with UConn staff and the executive committee, could not determine those topics without the assistance of an additional, 40-hour per week employee. Accordingly, the Authority disallows the annual $173,000 cost for program management and FTEs. Lastly, there is no clear distinction between the resources already available to UI through the Eversource Energy Center and the resources that would be available to the Company through the CLEAN EARTH Initiative. The Company witness testified that UI already interacts with the Eversource Energy Center. Hr’g Tr. Mar. 2, 2023, 2045:14-18. The Company is requesting $150,000 in annual funding, as an entirely separate investment from the CLEAN EARTH Initiative, for weather modeling that would make use of the Eversource Energy Center. Ex. UI-EPP-1, pp. 26-27. While the Company states that the CLEAN EARTH initiative would be specifically tailored to UI’s distribution grid through UI geographic and system load data, the Company has already provided funds to the Eversource Energy Center to develop the Damage Prediction Model using UI geographic and system data. Interrog. Resp. CAE-15; Interrog. Resp. CAE-55. Thus, the Company has not demonstrated that the CLEAN EARTH Lab Initiative will avoid duplicating the resources available through the Eversource Energy Center. Despite these concerns, the Authority is cognizant of the potential benefits and timeliness of the CLEAN EARTH Lab. Fundamental research and innovation will be key to a resilient, affordable, and equitable energy transition. Additionally, the Authority recognizes that collaboration between the Company and UConn is a synergistic arrangement with benefits for the University, the Company, and the state. The CLEAN EARTH Initiative will allow UI to access UConn’s exceptional resources, which will allow the Company to apply advanced data and analytical tools to support the Company’s effective decision-making. Ex. UI-JA-1, p. 10. UConn will also benefit from the opportunity to engage with acute problems facing the energy sector today, especially those affecting Connecticut. The opportunity for students to work on real-world problems supports the development of a workforce that is ready to tackle these challenges directly out of school and may allow the Company to hire graduating students who want to continue working in the energy industry. Ex UI-CETP-REBUTTAL-1, p. 11. The Authority finds research projects that yield analytical tools or actionable insights directly relevant to UI’s operations or service territory to be the most promising. For example, the Company has demonstrated a need for improved flood forecasting tools as their current suite of flood forecasting products produce similar results and are no more than 70% accurate. Interrog. Resp. RSR-101. Additionally, the Company has indicated that UConn has a unique framework for evaluating compound flood risk scenarios involving heavy precipitation, surge, and sea level rise, which are critical flood risk factors for UI’s coastal substations. Id. Research that is specifically tailored to UI’s distribution system and relies on UI geographical, system, and load data are valuable research areas. Additionally, there are opportunities to conduct fundamental research that would be aligned with the Authority’s orders and guidance in other dockets. For example, the Authority has directed the EDCs to identify and quantify the incremental costs necessary to maintain or improve upon a baseline level of reliability performance. RE08 Decision, p. 42. The Company has proposed the Climate Change Impact Modeling key research area, which would study the effect of infrastructure improvement investments on gridPage 166 of 296
Connecticut Light and Power Company Docket No. 26-05-10 The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 31, 2026 OCC-507 Attachment 21 Page 166 of 296 OCC-507 CL&P Attachment 21 Docket No. 22-08-08 Page 166 of 296 Page 160 resilience. Ex. UI-JA-1, pp. 10-11. The Authority considers this line of research, one which is aligned with the Authority’s directives in other dockets, to be an appropriate use of ratepayer funds. Ultimately, the Authority finds that the proposed research areas of Outage and Flooding Forecasting, Climate Change Impact Modeling, and DER Adoption Analysis and Strategy are potentially promising for the provision of tangible, UI distribution-specific benefits to ratepayers. The Authority’s Proposed Final Decision included an allowance of 25% of the requested CLEAN EARTH Initiative funding (i.e., $56,250 annually and $281,250 over five years) from UI ratepayers for the portion of the proposal that would directly benefit UI ratepayers. However, the Company stated that it is unwilling to proceed with the CLEAN EARTH Initiative if its full funding request is not paid for by UI customers and, accordingly, advised that the Authority should remove all expenses associated with the CLEAN EARTH Initiative. UI Exceptions, p. 116. Consequently, and reluctantly, the Authority removes the total annual expense of $398,000 for the CLEAN EARTH Initiative from the Company’s revenue requirement. The Authority is sincerely disappointed that Avangrid’s shareholders are unwilling to contribute a fair share towards the proposed CLEAN EARTH Initiative expenses, particularly given the clear benefits to their corporate interests, or to request a similar fair share from their other jurisdictions that would benefit greatly from the CLEAN EARTH Initiative. The Authority has great respect and admiration for the meaningful work performed at UConn and the professionals at that prestigious academic institution. The Authority encourages UConn to consider bringing a proposal to move forward with the CLEAN EARTH Initiative outside of this proceeding. The Authority respectfully requests that any independent proposal address how best to incorporate PURA, DEEP’s Bureau of Energy and Technology Policy, and the OCC in the governance structure of the CLEAN EARTH Initiative to ensure that the interests of Connecticut’s ratepayers, who would provide funding for the initiative, and the state’s energy policy perspectives and expertise are explicitly represented in the direction of the organization. b. Municipal Dashboard The Company is implementing a Municipal Dashboard to facilitate emergency response coordination and communication with municipalities in its service territory. EPP PFT, p. 23. The Company proposed to capitalize each year the approximate $825,000 annual cost of the Municipal Dashboard as a software-as-a-service asset. Interrog. Resp. OCC-537; Interrog. Resp. OCC-310, Att. 1. The Authority declined to approve the capitalization of the Municipal Dashboard in Section IV.H, Municipal Dashboard. Following the Authority’s investigation into the response to Tropical Storm Isaias, the Authority directed UI to perform outreach to municipalities to “identify the most relevant information for municipal leaders and best form(s) (e.g., call from municipal liaison, email from company and/or liaison, email and call from liaison, etc.) of communicating such information during the first 48 hours of a storm response.” 20-0803 Decision, p. 115. In response, UI conducted face-to-face outreach with each municipality. Interrog. Resp. OCC-611. One lesson from that outreach was using an
Text of OCC-507 Attachment 20.pdf
Extracted from the file · 167 pages · 508,170 characters
Text of OCC-507 Attachment 19.pdf
Extracted from the file · 137 pages · 450,996 characters
Text of OCC-507 Attachment 18.pdf
Extracted from the file · 247 pages · 763,200 characters
Text of OCC-507 Attachment 17.pdf
Extracted from the file · 2 pages · 6,387 characters
Text of OCC-507 Attachment 16.pdf
Extracted from the file · 2 pages · 484 characters
Text of OCC-507 Attachment 15.pdf
Extracted from the file · 202 pages · 895,816 characters
Text of OCC-507 Attachment 14.pdf
Extracted from the file · 6 pages · 8,947 characters
Text of OCC-507 Attachment 13.pdf
Extracted from the file · 19 pages · 93,122 characters
Text of OCC-507 Attachment 12.pdf
Extracted from the file · 19 pages · 95,631 characters
Text of OCC-507 Attachment 11.pdf
Extracted from the file · 7 pages · 10,667 characters
Text of OCC-507 Attachment 8.pdf
Extracted from the file · 2 pages · 3,673 characters
Text of OCC-507 Attachment 4.pdf
Extracted from the file · 6 pages · 8,272 characters
Text of OCC-507 Attachment 2.pdf
Extracted from the file · 8 pages · 30,345 characters
Text of OCC-507 Attachment 1.pdf
Extracted from the file · 32 pages · 164,962 characters
Text of OCC-507 Attachment 39.pdf
Extracted from the file · 22 pages · 32,510 characters
Text of OCC-507 Attachment 31.pdf
Extracted from the file · 8 pages · 37,747 characters
Text of OCC-507 Attachment 30.pdf
Extracted from the file · 5 pages · 22,063 characters
Text of OCC-507 Attachment 10.pdf
Extracted from the file · 3 pages · 4,485 characters
Text of OCC-507 Attachment 9.pdf
Extracted from the file · 10 pages · 15,175 characters
Text of OCC-507 Attachment 7.pdf
Extracted from the file · 3 pages · 5,747 characters
Text of OCC-507 Attachment 6.pdf
Extracted from the file · 4 pages · 6,545 characters
Text of OCC-507 Attachment 5.pdf
Extracted from the file · 4 pages · 5,724 characters
Text of OCC-507 Attachment 3.pdf
Extracted from the file · 65 pages · 195,008 characters
As listed on the current system
Question(s) Answered 507, 508, 509, 510, 511, 512, 517, 518 (The Connecticut Light and Power Company dba Eversource Energy) Date Filed: 09/14/2026