Skip to main content

A prototype public docket site for the Connecticut Public Utilities Regulatory Authority

Utility Dockets and Filings

Interrogatory responses

Answers to questions 507, 508, 509, 510, 511, 512, 517, 518

ResponseFiled by The Connecticut Light and Power Company dba Eversource Energy53 files
Part of docket 26-05-10Open
  • Electric
Application of The Connecticut Light and Power Company d/b/a Eversource Energy to Amend its Rate Schedules

Files53

Text of OCC-510_Final.pdf

Extracted from the file · 3 pages · 6,553 characters

Text of OCC-511_Final.pdf

Extracted from the file · 8 pages · 17,894 characters

Text of OCC-512_Final.pdf

Extracted from the file · 1 page · 992 characters

Text of OCC-517_Final.pdf

Extracted from the file · 1 page · 826 characters

Text of OCC-518_Final.pdf

Extracted from the file · 1 page · 601 characters

Text of OCC-512 Attachment 3 REDACTED.pdf

Extracted from the file · 33 pages · 5,436 characters

Text of OCC-512 Attachment 2 REDACTED.pdf

Extracted from the file · 33 pages · 5,436 characters

Text of OCC-512 Attachment 1.pdf

Extracted from the file · 626 pages · 635,148 characters

Text of OCC-507 Attachment 42.pdf

Extracted from the file · 3 pages · 10,259 characters

Text of OCC-507 Attachment 41.pdf

Extracted from the file · 9 pages · 3,276 characters

Text of OCC-507 Attachment 40.pdf

Extracted from the file · 5 pages · 8,775 characters

Text of OCC-507 Attachment 38.pdf

Extracted from the file · 19 pages · 96,311 characters

Text of OCC-507 Attachment 37.pdf

Extracted from the file · 49 pages · 120,692 characters

Text of OCC-507 Attachment 36.pdf

Extracted from the file · 59 pages · 136,630 characters

Text of OCC-507 Attachment 35.pdf

Extracted from the file · 38 pages · 102,807 characters

Text of OCC-507 Attachment 34.pdf

Extracted from the file · 5 pages · 1,210 characters

Text of OCC-507 Attachment 33.pdf

Extracted from the file · 13 pages · 52,489 characters

Text of OCC-507 Attachment 32.pdf

Extracted from the file · 5 pages · 14,030 characters

Text of OCC-507 Attachment 29.pdf

Extracted from the file · 8 pages · 37,747 characters

Text of OCC-507 Attachment 28.pdf

Extracted from the file · 18 pages · 75,925 characters

Text of OCC-507 Attachment 27.pdf

Extracted from the file · 35 pages · 66,295 characters

Text of OCC-507 Attachment 26.pdf

Extracted from the file · 19 pages · 68,589 characters

Text of OCC-507 Attachment 25.pdf

Extracted from the file · 12 pages · 53,851 characters

Text of OCC-507 Attachment 24.pdf

Extracted from the file · 2 pages · 482 characters

Text of OCC-507 Attachment 23.pdf

Extracted from the file · 268 pages · 869,686 characters

Text of OCC-507 Attachment 22.pdf

Extracted from the file · 178 pages · 528,336 characters

Text of OCC-507 Attachment 21.pdf

Extracted from the file · 296 pages · 1,013,669 characters

Text of OCC-507 Attachment 20.pdf

Extracted from the file · 167 pages · 508,170 characters

  1. Page 11 of 137

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 31, 2026 OCC-507 Attachment 19 Page 11 of 137 Connecticut Light and Power Company Docket No. 26-05-10 Docket No. 16-06-04 OCC-507 CL&P Attachment 19 Page 11 of 137 Page 7 ratepayers. UI's customers should not be required to pay for a more costly tree trimming program at this time. UI failed to demonstrate the cost-effectiveness of ETT or UPZ. Despite the $25 million that ratepayers have invested in ETT to date, UI was unable to show that its storm costs have declined or that its reliability has improved. Further, UI has not projected any storm cost savings for first six years of the UPZ program. The AG urged the Authority to reject UI's claims that the entire UPZ program should be completed before results of the program can be measured. Response to Interrogatory OCC-353. As UI trims trees to the ETT or UPZ standard, the incremental benefits of such trimming should be measurable in terms of storm cost savings and increased reliability, but UI has failed to demonstrate such benefits to date. Lastly, the AG recommended that the Authority reject the Company's assertion that a cause of the increased cost of UPZ is that its tree density turned out to be greater than it expected. It is not credible to believe that UI, which has provided electric distribution service in its 17-town service territory since 1899, is unaware of the tree density along its distribution line rights-of-way. Brief, pp. 27 and 28. In the 2013 UI rate case, the Authority was concerned over the effect that the ETT program would have on rates. The Authority intended to fund the annual ETT expenditures in an optimal way by allowing UI to spend $12.5 million per year and to amortize the annual expenditures over five years, to hold rates at a reasonable level. 2013 UI Rate Case Decision, p. 14. UI’s proposed increase of $62.5 million and the expansion of the program from eight to ten years compels the Authority to look closely at the near term and lifetime recovery of the UPZ costs and revenue requirements. In its consideration of the need to maintain the sustainability of the program and control rate impacts, cost recovery of the proposed increase would be more reasonable and affordable for customers by extending UI’s UPZ program to 12 years, and requiring that all new expenditures occurring after 2016 be expensed. The expenditures would be increased to $13 million in 2017, $13.8 million in 2018 and $14 million in 2019 to be continued through 2025. These allowances should fully fund the work intended in the new UPZ program. During the phase out of the remaining amortized recovery period and the changeover to expensing UPZ costs, revenue requirements would increase $9.8million in 2017 and $4.8million in 2018 compared to UI’s proposal with a five-year amortization of annual expenditures. However, these increases will be offset by revenue reductions in the following 2.7 years and ratepayers will save an additional $16.6 million over the remaining life of the program compared to the UI proposal, as shown below. The results shown below were computed by the Authority through the use of UI’s UPZ revenue requirements model provided in its response to Late Filed Exhibit No. 28 using 50% equity, 50% debt and a ROE of 9.10% for years 2017 through 2027.
  2. Page 12 of 137

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 31, 2026 OCC-507 Attachment 19 Page 12 of 137 Connecticut Light and Power Company Docket No. 26-05-10 OCC-507 CL&P Attachment 19 Page 12 of 137 Docket No. 16-06-04 Page 8 UPZ Program: Annual Expenditures and Revenue Requirements ($000) Description Program Year Expenditures/Revenue Requirements UI 2013 Allowed Expenditures RR-amortized 5 yrs UI Proposed Expenditures RR-amortized 5 yrs PURA Expenditures expensed aft 2016 PURA RR Amortized 2014-2016 PURA RR Expensed 2017 &+ 1 2013 Decision 2 3 4 Rate Years 5 6 7 8 9 Beyond Rate Years 10 11 12 13 14 Lifetime Total 2014 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 $ 100,000 $ 12,500 $ 12,500 $ 12,500 $ 12,500 $ 12,500 $ 12,500 $ 12,500 $ 12,500 $ 122,117 $ 3,047 $ 6,343 $ 9,472 $ 12,466 $ 15,260 $ 15,268 $ 15,274 $ 15,274 $ 12,220 $ 8,914 $ 5,775 $ 2,804 $ 162,467 $ 10,339 14,446 12,900 $ 17,601 $ 22,604 $ 22,648 $ 22,817 $ 22,889 $ 10,694 $ 5,529 $ 198,443 $ 2,520 $ 6,247 $ 9,542 $ 13,793 $ 19,153 $ 22,229 $ 24,319 $ 26,636 $ 24,850 $ 20,430 $ 14,706 $ 9,065 $3,713 $1,240 $ 162,485 $ 10,339 14,446 12,900 $ 13,000 $ 13,800 $ 14,000 $ 14,000 $ 14,000 $ 14,000 $ 14,000 $ 14,000 $ 14,000 45,984 2,520 6,247 9,542 9,493 8,984 6,305 2,894 135,798 14,146 15,016 15,234 15,234 15,234 15,234 15,234 15,234 15,234 RR-Amtzed to 2016 & expensed 2017 &+ $ 181,783 $ 2,520 $ 6,247 $ 9,542 $ 23,638 $ 24,000 $ 21,538 $ 18,127 $ 15,234 $ 15,234 $ 15,234 $ 15,234 $ 15,234 RR Diff: UI Proposed - UI 100 RR Diff: PURA -UI Proposed CUM Savings: PURA-UI Proposed $ 71,373 $ (527) $ (96) $ $ (16,660) 70 $ 1,327 $ 3,893 $ 6,961 $ 9,044 $ 11,361 $ 12,630 $ 11,517 $ 8,931 $ 6,261 $ 3,713 $ 1,240 9,845 4,847 (691) (6,191) (11,402) (9,616) (5,197) 528 6,169 (3,713) (1,240) (9,845) (14,693) (14,002) (7,811) 3,591 13,207 18,403 17,876 11,707 15,420 16,660 Revenue Requirements Calculations using UI Late Filed Exhibit No. 28. The Authority recognizes that hazard and danger trees are the same in the UPZ. The term danger tree is not defined in the UPZ plan or by the Authority in the Decision dated June 25, 2014, in Docket No. 12-01-10, PURA Investigation Into the Tree Trimming Practices of Connecticut's Utility Companies (2014 Tree Trimming Decision). The UPZ plan is reviewed annually by the Authority in the transmission and distribution maintenance dockets. See for example, Docket No. 15-12-20, PURA Review of Electric Companies’ and Electric Distribution Companies’ Plans for Maintenance of Transmission and Distribution Overhead and Underground Lines. Furthermore, in the Decision dated June 17, 2015, in Docket No. 14-07-18, PURA Report to the General Assembly Concerning Its Review of Each Electric Distribution Company’s Vegetation Management Practices (2014 Report), the Authority concluded that the electric distribution companies’ (EDCs) most current vegetation management plans meet the requirements of the Conn. Gen. Stat. §16-234 and the 2014 Tree Trimming Decision. 2014 Report, p. 16. The Authority observed the benefits of the ETT program as demonstrated in the Company’s service reliability dockets since 2012 and expects improved annual reliability as the UPZ is implemented. The Company still projects at least a 25% reduction in day-to-day reliability with tangential benefits for withstanding damage in severe weather events. Reed and Thomas PFT, p. 35. The Authority notes that less than half of the proposed $62.5 million increase is due to actual tree maintenance work. Approximately 15% of the proposed increase results from greater legislative and PURA requirements to obtain consent, make modifications and ensure that property owners understand the tree work to be performed before it occurs. The cost of traffic control has also been increasing at a high rate. In UI’s 2013 ETT plan, traffic control was estimated to be $13 million or 13% of the vegetation management program costs. Through 2014 and 2015, the actual traffic control costs increased to 19% of program costs and now is projected to exceed $40 million or 24% of the UPZ program. Responses to Interrogatories EN-64, EN-68 and OCC-273. Although the Authority does not have jurisdiction over traffic control, it encourages the EDCs to work with legislators and town officials to allow flagmen to
  3. Page 13 of 137

    Connecticut Light and Power Company Docket No. 26-05-10 The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 31, 2026 OCC-507 Attachment 19 Page 13 of 137 OCC-507 CL&P Attachment 19 Docket No. 16-06-04 Page 13 of 137 Page 9 direct traffic as much as possible. In the towns with high traffic control costs, the Company should request a wider UPZ where consent can be obtained from the property owner. The Authority hereby approves expenditures for the UPZ Program of $13 million for 2017, $13.8 million for 2018 and $14 million for 2019 and annually thereafter, until the total cost reaches $162 million for the program life. All UPZ costs occurred in 2017 and thereafter will be expensed. The UPZ Program and funding will be re-evaluated in the Company’s next rate proceeding. 3. Direct Contact Program As a result of slower progress in establishing the UPZ, the amount of direct tree contact with energized primary lines has increased. A Direct Contact Program dedicated to clearing the direct tree contacts is necessary to ensure the safety and reliability of the electric system until the UPZ Program is completed and the normal routine maintenance cycle begins. Reed and Thomas PFT, pp. 35 and 36. The expected cost of this program is $839,000 in 2017, $836,000 in 2018 and $833,000 in 2019. Application, WP C-3.5 A-C. The AG claimed that the Company collects more than an adequate amount from its ratepayers to fund vegetation management. UI proposed rates include $860,000, $876,000 and $901,000 for years 2017, 2018, and 2019 respectively, for its Reliability Line Clearance Program. Application, Schedule C-3.5. The Authority approved $100 million for vegetation management for the ETT Program. Thus, any costs associated with trees that are in direct contact with lines, should therefore come out of the Company's existing tree trimming budgets. AG Brief, p. 29. The AG noted that UI spent less than authorized amounts on its routine tree trimming in 2014 and 2015. UI collected $1.9 million from ratepayers in 2014 and $0.9 million in 2015 for non-ETT vegetation management. Response to Interrogatory OCC-61. These dollars should have contributed to the prevention of direct contact of trees on UI's distribution lines during the Company's routine trim cycle. However, the Company only spent $1.4 million on vegetation management in 2014 and $0.6 million in 2015. Response to Interrogatory OCC-60. Therefore, the AG recommended that the Authority deny new tree trimming programs when the Company failed to spend the ratepayer funded vegetation management funds already in place. Also, the Authority should maintain the tree trimming and vegetation management dollars approved in the 2013 UI rate case, including ETT. Additionally, the Company should use those dollars more effectively rather than collect more from its ratepayers for the same purpose. Lastly, the AG recommended that the Authority reject UI's proposal for separate funding of the Direct Contact program. Id. The OCC stated that direct contact is supposed to be controlled and/or eliminated by maintaining a proper trim cycle. A proper trim cycle addresses growth related contact by identifying the annual growth and trimming the entire system in segments. The OCC concurred with the AG and recommended that the entire amount proposed by UI for the Direct Contact Program be disallowed. Schultz III/Defever PFT, pp. 69 and 70.
  4. Page 14 of 137

    Connecticut Light and Power Company Docket No. 26-05-10 The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 31, 2026 OCC-507 Attachment 19 Page 14 of 137 OCC-507 CL&P Attachment 19 Docket No. 16-06-04 Page 14 of 137 Page 10 The Authority recognizes that the progress of the UPZ Program has been hindered due to the consent process required by 2014 legislation and additional Authority requirements in the 2014 Tree Trimming Decision. It also recognizes the large amount of new funding allowed for ETT and requested for the UPZ Program. The Authority notes that the Company’s annual Vegetation Management plan has never addressed the issue of excessive branch contact with its lines. A new Direct Contact Program with proposed expenditures of $839,000, $836,000 and $833,000 for years 2017 to 2019 should not be funded by ratepayers at this time especially with the large funding increase the Authority allowed for the UPZ program above. Therefore, the Authority disallows the proposed Direct Contact Program. As the UPZ is established over the next nine years, tree clearance will decrease for trees trimmed prior to the 2014 ETT Program but not every tree branch will be too close to wires or make contact with energized wires. However, to ensure public safety and maintain reliability due to the time extension allowed in establishing the UPZ, the Authority will permit the requested Reliability Line Clearance Program expenditures to be increased by one half of the proposed rate year direct contact budgets for the removal of branches in direct contact with primary wires. Therefore, the Authority approves increased expenditures for the Reliability Line Clearance Program of $420,000, $418,000 and $417,000 for years 2017 to 2019. The total approved budgets for the line clearance expense are $1,280,000 for 2017, $1,294,000 for 2018 and $1,318,000 for 2019, which includes removal of all branches in direct contact with UI energized lines. The Authority expects the unit costs of direct contact removals to be less than UPZ work. Conn. Gen. Stat. §16-234(e) does not require the EDCs to obtain a permit or provide notice to property owners to prune or remove a tree, as necessary, if any part of a tree is in direct contact with an energized electrical conductor or has visible signs of burning. The Authority expects UI to manage the direct contact condition with the line clearance funds, prioritizing high growth vegetation areas within the UPZ program and realize at least an 81% consent rate for full UPZ. The Company will be directed to include the management of this issue in its future vegetation management plans and it will be reviewed in the Company’s next rate proceeding. The Company will be required to obtain data and file results of direct contact work and its management to justify the continuance of this funding. 4. Regulatory Asset and Liability - Utility Protection Zone UI requested an UPZ regulatory asset, net of related accumulated amortization, of $23.123 million for 2016, $29.667 million for 2017, $36.693 million for 2018 and $41.301 million for 2019. The requested average UPZ regulatory asset, net of related accumulated amortization is $26.395 million for 2017, $33.183 million for 2018 and $38.997 million for 2019. The Company reported offsetting accumulated deferred income taxes (ADIT) of $9.446 million for 2016, $12.119 million for 2017, $14.810 million for 2018 and $16.469 million for 2019. The proposed average UPZ ADIT is $10.783 million for 2017, $13.465 million for 2018 and $15.640 million for 2019. Application, Schedules B-1.0 A, B and C; B-6.2 A, B and C. Based on the Authority’s determination, as described in Section II.B.2. Utility Protection Zone, directing the Company to expense UPZ expenditures for periods after
  5. Page 15 of 137

    Connecticut Light and Power Company Docket No. 26-05-10 The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 31, 2026 OCC-507 Attachment 19 Page 15 of 137 OCC-507 CL&P Attachment 19 Page 15 of 137 Docket No. 16-06-04 Page 11 2016 and not treat them as regulatory assets, the Authority removes the rate base impacts of the proposed UPZ expenditures for periods subsequent to 2016 from the allowed rate base for each rate year. The table below summarizes the allowed net UPZ regulatory assets for 2016 through 2019: Calculation of Net UPZ Regulatory Asset Net of Deferred Income Taxes ($000) Descriptions Net UPZ Regulatory Asset ADIT Net UPZ Regulatory Asset net of ADIT 2016 $23,123 ( 9,446) $13,677 2017 $15,586 ( 6,367) $9,219 2018 $8,049 ( 3,249) $4,800 2019 $2,580 ( 1,029) $1,551 As determined in the table above, the Authority finds that the allowed average UPZ regulatory assets, net of related accumulated amortization, are $19.355 million [($23.123 +$15.586) / 2)] for 2017, $11.818 million [($15.586 + $8.049) / 2] for 2018 and $5.315 million [($8.049 + $2.580) / 2] for 2019. Thus, the Company’s proposed average UPZ regulatory assets are reduced by $7.041 million ($26.395 - $19.355) in 2017, $21.363 million ($33.183 - $11.818) in 2018 and $33.682 million ($38.997 - $5.315) in 2019. Similarly, the Authority finds that the average UPZ ADIT are $7.907 million [($9.446 +$6.367) / 2] for 2017, $4.808 million [($6.367 + $3.249) / 2] for 2018 and $2.139 million [($3.249 + $1.029) / 2] for 2019. Therefore, average UPZ ADIT are reduced by $2.876 million ($10.783 - $7.907) in 2017, $8.657 million ($13.465 - $4.808) in 2018 and $13.501 million ($15.640 - $2.139) in 2019. Thus, the average net UPZ regulatory assets in rate base are overstated as summarized in the table below: Calculation of Net Average UPZ Regulatory Asset Disallowed ($000) Description Net UPZ Regulatory Asset Requested Less Net UPZ Regulatory Asset Allowed Net UPZ Regulatory Asset Reduction UPZ ADIT Requested Less UPZ ADIT Allowed UPZ ADIT Reduction Net UPZ Regulatory Asset Disallowed 5. A B C=A-B D E F=D-E G=C-F 2017 $26,395 (19,355) 7,041 10,783 ( 7,907) 2,876 $4,165 2018 $33,183 (11,818) 21,363 13,465 ( 4,808) 8,657 $12,706 2019 $38,997 ( 5,315) 33,683 15,640 ( 2,139) 13,501 $20,182 Net General and Intangible Plant Allocated to Transmission The total distribution utility plant-in-service, which is comprised of intangible distribution and general balances, reported as of December 31, 2015, was $1,600.142 million. Application, Schedule B-1.0 A. The total plant-in-service balance for the three classes of utility plant reported in the Company’s 2015 Federal Energy Regulatory Commission Form 1 (2015 FERC Form 1) was $1,656.328 million. Application, Schedule H-1.1, p. 207. UI reported total accumulated depreciation of $430.197 million for the three classes of distribution plant-in-service as of December 31, 2015. Application, Schedule B-1-0 A. The total accumulated depreciation balance for the three classes of utility plant reported in the 2015 FERC Form 1 was $462.325 million. Application, Schedule H-1.1, pp. 200 and 219. UI testified that the differences between the amount reported in its 2015 FERC Form 1 report and the SFR schedules are
  6. Page 16 of 137

    Connecticut Light and Power Company Docket No. 26-05-10 The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 31, 2026 OCC-507 Attachment 19 Page 16 of 137 OCC-507 CL&P Attachment 19 Docket No. 16-06-04 Page 16 of 137 Page 12 associated with intangible and general plant amounts allocated to transmission plant. It used a wage allocation factor of 15.07% to allocate general and intangible plant, along with the related accumulated depreciation amounts to transmission. Application, Schedule H-1.6; Tr. 09/12/16, pp. 88-90; Tr. 10/06/16, pp. 1818 and 1819. Based on its review of information provided in this proceeding, the Authority summarizes the differences between distribution plant and accumulated depreciation as reported in the table below: Description: Distribution per 2015 FERC Form 1 Intangible per 2015 FERC Form 1 General per 2015 FERC Form 1 Total Distribution Plant per 2015 FERC Form 1 Total Distribution Plant per SFR Schedules Differences December 31, 2015 Ending Balances Accumulated Plant-in-Service Depreciation $1,280,757,000 $294,622,000 102,542,000 94,953,000 273,030,000 72,750,000 1,656,328,000 462,325,000 1,600,142,000 430,197,000 $ 56,186,000 $ 32,128,000 Application, Schedules B-1.0 A; H-1.1. The $56.186 million difference between the 2015 total distribution plant amount reported in the Company’s SFR schedules and in the 2015 FERC Form 1 equals the difference between the $805.988 million transmission plant-in-service reported in UI’s response to Late Filed Exhibit No. 5 and the transmission plant ending balance of $749,802 million reported in the 2015 FERC Form 1. Application, Schedule H-1.1, p. 207; Late Filed Exhibit No. 5, p. 1. The $56.186 million difference also represents approximately 14.96% [($56.186 / ($102.542 + $273.030)] of the sum of the 2015 ending balances of the total intangible plant of $102.542 million and general plant of $273.030 million. However, the $32.128 million difference between the accumulated depreciation amounts via the SFR schedules and the 2015 FERC Form 1 is approximately 19.16% [($32.128 / ($94.953 + $72.750)] of the total amount of the ending balances of accumulated depreciation of intangible and general plant. This allocation factor is significantly higher than both the 14.96% calculated above and the 15.07% transmission wage factor that UI claimed was used to allocate intangible and general plant to transmission service. By allocating the 2015 ending balances of the accumulated depreciation to transmission using a factor larger than the one applicable to distribution plant allocated to transmission service, the Authority finds that UI overstated the net distribution plant-in-service amount as of December 31, 2015. Using the 14.96% determined herein as the factor used to allocate intangible and general plant to transmission, the Authority finds that the total ending balances of accumulated depreciation for intangible and general plant that should be allocated to transmission plant is $25.089 [(94.953 + 72.750) x 14.96%] million. As a result, the Authority determines that the accumulated depreciation for intangible and general plant that the Company allocated to transmission is overstated by $7.039 million ($32.128 - $25.089).
  7. Page 17 of 137

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 31, 2026 OCC-507 Attachment 19 Page 17 of 137 Connecticut Light and Power Company Docket No. 26-05-10 OCC-507 CL&P Attachment 19 Page 17 of 137 Docket No. 16-06-04 Page 13 The Company stated the proposed $7.039 million reduction to its rate base associated with the allocation of accumulated depreciation to transmission is erroneous. The Company indicated that the cost of removal (COR) is also allocated to transmission. UI specified that if the $7.013 million representing the transmission portion of UI’s COR regulatory liability is included, the allocation factor for plant-in-service and accumulated depreciation are identical to the 14.96% determined by the Authority. UI Written Exceptions, pp. 22 and 23. The Authority finds that the Company’s claim that the referenced $32.128 million included COR of approximately $7.013 million to be in error. The table below illustrates activities in accumulated depreciation in 2015: Item Descriptions 2015 Beginning Balance 2015 Depreciation Expense Retirements Cost of Removal Salvage Value Other Debits 2015 Ending Balance Amounts ($) 469,090,446 66,373,476 ( 21,112,226) ( 8,253,282) 870,888 638,687 507,607,989 2015 FERC Form 1, p. 219. The total 2015 COR of $8,253,282 is related to accumulated depreciation in Account 108. Id. The Company testified that the distribution portion of this amount is $7,681,784 and the balance of $571,498 is associated with transmission. Tr. 10/06/16, pp. 1878 and 1879. As indicated in the table above, none of the $8,253,282 COR is associated with accumulated amortization related to the intangible plant. The 2015 accumulated depreciation ending balance of $294.622 million for distribution plant already reflected a reduction for the COR. Id., p. 219. Also, based on the negative salvage percentages associated with distribution plant accounts, the Authority concluded that the entire $7,681,784 is mainly related to accumulated depreciation for distribution plant-in-service and very little is associated with general plant-in-service. Id., 337. There is no basis for UI to associate COR related to distribution plant-in-service with accumulated depreciation related to intangible and general plants. Therefore, none of the COR related to distribution plant-in-service should be used to gross-up the amount of accumulated depreciation allocated to transmission service. The Authority determines that the total net accumulated depreciation for intangible and general plants, after allocation to transmission is $142.431 million ($167.703 – $25.089). Therefore, the total accumulated depreciation for the three classes of distribution is $437.053 million ($294.622 + $142.431). This is approximately $6.856 million more than 2015 total distribution accumulated depreciation of $430.197 million reported by UI. Hence, the Authority reduces the proposed rate base in the rate years by $6.856 million.
  8. Page 18 of 137

    Connecticut Light and Power Company Docket No. 26-05-10 The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 31, 2026 OCC-507 Attachment 19 Page 18 of 137 OCC-507 CL&P Attachment 19 Page 18 of 137 Docket No. 16-06-04 6. Page 14 Capital Expenditures a. General UI’s proposed capital expenditures (Capital Program) disaggregated by category for the Rate Year is as follows: Proposed Capital Program for Rate Years 2017 – 2019 Categories Capacity Customer Reliability - Corrective Infrastructure Replacement - Substations Infrastructure Replacement - Distribution System Modernization and Operational Excellence System Resiliency System Operations Business Effectiveness Total 2017 2,312 37,272 5,052 18,882 24,920 (3,885) 6,032 10,525 4,416 $105,526 $ in thousands 2018 1,489 38,197 2,219 8,550 28,828 2,021 6,234 11,974 883 $100,394 2019 1,948 38,698 2,712 8,416 28,748 3,720 4,752 9,298 3,900 $102,191 Note: Amounts may not add due to rounding. Reed and Thomas PFT, p. 5. The Capital Program consisted of expenditures for programs that address the needs of customers and system reliability and strengthens the system against major storms. Every year, the Company develops a ten-year capital forecasting plan that assesses system needs and potential solutions to system issues. From this process, the Company determines the investments required to meet distribution business objectives. Id. The Company outlined the key objectives for the Capital Program, which includes supporting the day to day functions of installing new services, responding to customer requests about service changes, responding to emergencies and numerous other projects to construct, and repair and replace distribution facilities to maintain reliability 2016 2017 and meet customer needs. Id., p. 4. Capacity $ 159 $ 2,312 $ in thousands 2018 $ 1,489 2019 $ 1,948 The Capital Program is Customer separate from the UI Storm Resiliency Plan 33,199 (Resiliency37,272 38,197 38,698 Plan) which has been approved in the -Decision Reliability Correctivedated October 26, 2016 in Docket 5,693 No. 5,052 2,219 2,712 Infrastructure Replacement Substations 2016 Storm 7,070 8,550 8,416 16-07-11, PURA Review of The United Illuminating Company’s Resiliency18,882 Infrastructure Replacement - Distribution System to the 13,326 28,828 28,748 Plan (Resiliency Decision). The Resiliency Plan was filed pursuant merger24,920 and Operational Excellence 9, 2015 in Docket 10,316 No.(3,885) 2,021 3,720 settlement agreement approvedModernization in the Decision dated December System Resilency 6,170 6,032 6,234 4,752 15-07-38, Joint Application of Iberdrola, S.A, Iberdrola USA, Networks Inc., Green System Operations 20,667 10,525 11,974 9,298 Merger Sub, Inc. and UIL Holdings Corporation for Approval of a Change of Control Business Effectiveness 1,958 4,416 883 3,900 (2015 Iberdrola Change of Control Decision). The Resiliency Plan included programs $ 98,557 $ 105,526 $ 100,394 $ 102,191 costing an additional $50 million over four years. The programs are complimentary to the resiliency expenditures outlined above. The associated costs for the Resiliency Plan programs will be recovered through the non-bypassable Federally Mandated Congestion Charge (NBFMCC), which is outside of base distribution rates. Neither the OCC nor the AG opposed the Resiliency Plan. Resiliency Decision, p. 7.
  9. Page 19 of 137

    Connecticut Light and Power Company Docket No. 26-05-10 The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 31, 2026 OCC-507 Attachment 19 Page 19 of 137 OCC-507 CL&P Attachment 19 Page 19 of 137 Docket No. 16-06-04 Page 15 The OCC and the AG contended that the Company’s capital expenditures should be reduced by up to 20% of UI’s proposed budget. They specified concerns with the Company’s recent management of its capital budget and UI’s lack of addressing the Authority’s cost benefit analysis concerns outlined in the 2013 UI Rate Case Decision. The AG and OCC highlighted the variance in the Company’s capital budget and actual expenditures for the years 2013-2015. AG Brief, pp. 7-12; OCC Brief, pp. 5-11. The table below illustrates that UI’s actual capital expenditures from 2013 through 2015 were approximately 20% below that allowed by the 2013 UI Rate Case Decision.3 UI Allowed and Actual Capital Expenditures 2013-2015 Categories Capacity Customer Reliability - Corrective Infrastructure Replacement - Substations Infrastructure Replacement - Distribution System Modernization and Operational Excellence System Resiliency System Operations Business Effectiveness Total Actuals 31,302 102,389 6,260 36,528 50,442 23,763 20,548 48,049 862 $320,143 2013-2015 ($ in thousands) Allowed DN 13-01-19 Variance 45,439 (14,137) 102,702 (313) 10,328 (4,068) 59,391 (22,863) 50,019 423 45,874 (22,111) 20,329 219 55,178 (7,129) 9,847 (8,985) $399,108 $78,965 % Variance -31.11% -0.30% -39.39% -38.50% 0.85% -48.20% 1.08% -12.92% -91.25% 19.79% Note: Amounts may not add due to rounding. Response to Interrogatory OCC-257. The AG and the OCC also noted that as of the first two quarters of 2016, the Company underspent by 22% of its 2016 Capital Program budget. Late Filed Exhibit No. 23. The AG and OCC also argued that UI underspent by 16% from the years 2011-2015 in the resiliency category. Larkin PFT, p. 16; AG Brief, p. 7. Besides concerns with the 2013-2015 Allowed Company’s capital expenditure underspending, there are deeper concerns with UI’s Actuals DN 13-01-19 management that may be causing this trend. The OCC urged the Authority to place less Variance emphasis on the Company’s explanation for the project delays$ that contributed Capacity 31,302 $ 45,439 $ (14,137) Customer and instead focus on the distinct 102,389 pattern 102,702 (313) significantly to UI’s recent underspending of Reliability Corrective 6,260 10,328 (4,068) underspending and postponing projects. OCC Brief, p. 9. Infrastructure Replacement - Substations 36,528 59,391 (22,863) Infrastructure Replacement - Distribution System 50,442 50,019 Modernization and OEI 23,763 45,874 The OCC’s witness claimed that UIL had been facing financial pressure during System Resiliency 20,548 20,329 2014 and 2015 due to $60 million in costs of two attempted mergers. UI 48,049 acknowledged System Operations 55,178 that it was asked to reduce its budget to manage Specifically, Business Effectiveness the entire UIL portfolio. 862 9,847 UIL asked the Company to shift money from the UI capital budget to support the growth 320,143 $ 399,108 $ of UIL’s gas expansion program. UI stated that there have been$ times when the Company’s capital budget was increased at the expense of other areas of the UIL portfolio. Tr. 9/14/16, pp. 585, 586 and 708. Finally, the AG and the OCC argued that the Company’s lack of a cost-benefit analysis further supported their argument to reduce UI’s capital budget by 20%. AG 3 In the 2013 UI rate case, the Authority approved the Company’s capital plan for a two-year period beginning mid-2013 and ending mid-2015. Thomas Rebuttal Testimony, p. 6. Response to Interrogatory EN-41; Favuzza, Reed and 423 (22,112) 219 (7,129) (8,985) -31% 0% -39% -38% 1% -48% 1% -13% -91% (78,965) -20%
  10. Page 20 of 137

    Connecticut Light and Power Company Docket No. 26-05-10 The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued August 31, 2026 OCC-507 Attachment 19 Page 20 of 137 OCC-507 CL&P Attachment 19 Page 20 of 137 Docket No. 16-06-04 Page 16 Brief, p. 12; OCC Brief, p. 10. The AG cited the 2013 UI rate case where the Authority outlined the three characteristics (justification, affordability, and redefining the paradigm) that it considered when evaluating UI’s proposed capital plan. Brief, p. 8. The AG and the OCC argued that the Company’s Capital Program does not satisfy the cost-benefit characteristic outlined in the 2013 UI Rate Case Decision and that any capital program at the levels proposed by UI requires a more exhaustive cost-benefit analysis process. AG Brief, p. 10; OCC Brief, p. 10. The Company argued that the Authority should consider the years 2004 to 2015 to assess UI’s spending of its allowed budget where it has overspent by $37.77 million or 3.6%. Favuzza, Reed and Thomas Rebuttal Testimony, p. 5. The table below compares UI’s spending for these years. Allowed and Actual Capital Expenditures 2004-2015 2004-2015 ($ in thousands) Categories Capacity Customer Reliability - Corrective Infrastructure Replacement - Substations Infrastructure Replacement - Distribution System Modernization and Operational Excellence System Resiliency System Operations Business Effectiveness Total Actuals 100,385 353,146 33,506 68,123 244,994 28,045 27,810 168,211 63,239 $1,087,457 Allowed/Filed 122,834 260,371 23,216 97,415 207,051 46,030 26,613 173,748 92,402 $1,049,681 Variance (22,450) 92,775 10,290 (29,293) 37,943 (17,985) 1,197 (5,537) (29,163) $37,776 % Variance -18% 36% 44% -30% 18% -39% 4% -3% -32% 3.60% Note: Amounts may not add due to rounding. Response to Interrogatory EN-41. UI justified the underspending for each of the categories that contributed largely to the variance. In the capacity category, UI experienced a decrease in peak demand and forecasted only a modest load growth in the future. Specifically, substation load relief projects were 10% less than originally projected. . In the Reliability-Corrective Program, UI incurred $3 million less than originally projected since the need to rebalance feeders to address overloads did not materialize. Response to Interrogatory OCC-257. The Infrastructure Replacement - Substations category saw a $22 million reduction in spending due primarily to the reprioritization of substation rebuilds and removals. Most significantly, the Company began work to rebuild the Old Town substation as planned, when a new generator coming online required UI to shift work to rebuild the Baird substation to accommodate new generation into the system. This ultimately resulted in a shift of the Old Town substation rebuild to 2018. Tr. 9/14/16, pp. 466 and 467. The Authority notes that the above occurrences were largely outside of the Company’s control. Additionally, a reprioritization of low voltage substation removals ultimately resulted in two lower cost removals moving ahead of a higher cost one that was originally planned. Id., p. 467. Finally, in the Modernization and Operational Excellence and Business Effectiveness categories, a bulk of the underspending was the result of an accounting treatment whereby the Company shifted the capital expenditure to UIL since the scope of these projects involved its gas companies. Much of these funds would ultimately be allocated back to UI as an O&M expense. Response to Interrogatory OCC-257; Favuzza, Reed and Thomas Rebuttal Testimony, p. 7.

Text of OCC-507 Attachment 18.pdf

Extracted from the file · 247 pages · 763,200 characters

Text of OCC-507 Attachment 17.pdf

Extracted from the file · 2 pages · 6,387 characters

Text of OCC-507 Attachment 16.pdf

Extracted from the file · 2 pages · 484 characters

Text of OCC-507 Attachment 15.pdf

Extracted from the file · 202 pages · 895,816 characters

Text of OCC-507 Attachment 14.pdf

Extracted from the file · 6 pages · 8,947 characters

Text of OCC-507 Attachment 13.pdf

Extracted from the file · 19 pages · 93,122 characters

Text of OCC-507 Attachment 12.pdf

Extracted from the file · 19 pages · 95,631 characters

Text of OCC-507 Attachment 11.pdf

Extracted from the file · 7 pages · 10,667 characters

Text of OCC-507 Attachment 8.pdf

Extracted from the file · 2 pages · 3,673 characters

Text of OCC-507 Attachment 4.pdf

Extracted from the file · 6 pages · 8,272 characters

Text of OCC-507 Attachment 2.pdf

Extracted from the file · 8 pages · 30,345 characters

Text of OCC-507 Attachment 1.pdf

Extracted from the file · 32 pages · 164,962 characters

Text of OCC-507 Attachment 39.pdf

Extracted from the file · 22 pages · 32,510 characters

Text of OCC-507 Attachment 31.pdf

Extracted from the file · 8 pages · 37,747 characters

Text of OCC-507 Attachment 30.pdf

Extracted from the file · 5 pages · 22,063 characters

Text of OCC-507 Attachment 10.pdf

Extracted from the file · 3 pages · 4,485 characters

Text of OCC-507 Attachment 9.pdf

Extracted from the file · 10 pages · 15,175 characters

Text of OCC-507 Attachment 7.pdf

Extracted from the file · 3 pages · 5,747 characters

Text of OCC-507 Attachment 6.pdf

Extracted from the file · 4 pages · 6,545 characters

Text of OCC-507 Attachment 5.pdf

Extracted from the file · 4 pages · 5,724 characters

Text of OCC-507 Attachment 3.pdf

Extracted from the file · 65 pages · 195,008 characters

As listed on the current system

Question(s) Answered 507, 508, 509, 510, 511, 512, 517, 518 (The Connecticut Light and Power Company dba Eversource Energy) Date Filed: 09/14/2026

This filing on the current system (opens in a new tab)