  1. Page 58 of 191

    Docket No. 98-01-02 The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 28, 2026 OCC- 886 Attachment 1 Page 58 of 191 Page 51 comparison purposes only. The Department views the position of OCC and AG on this matter as supporting retroactive ratemaking and will not reduce nuclear O&M as these parties have requested. The Company identified the costs related to industry standards by function. OCC states that costs associated with a number of these functions should be disallowed. The following sections address each of these functions. a. Work Planning and Control The Company’s improvements to its work planning and control program include establishing a full time outage management staff, and ancillary costs associated with maintaining this staff. Response to OCC-177, Bulk, p. 1. OCC states that costs associated with the Work Planning and Control function should be disallowed since the Company did not identify any new or heightened industry standard requiring it, and these activities are necessary to raise the Company’s standards. Schlissel Testimony, p. 40. The Company states that the costs of this program are driven by the Maintenance Rule, which was an NRC regulation established in 1991 that became effective in 1996. The objective of the Maintenance Rule is to establish a performance-based maintenance system at each nuclear power plant that would result in performance of maintenance based on an assessment of risk. Response to Interrogatory OCC-182, Supplement 1, Bulk, Letter dated March 4, 1997, to NRC Commissioners from Joseph Callan, p. 2. The Company’s documentation on the Work Planning function indicates that implementation of the Maintenance Rule has increased quality requirements, resulting in increased training requirements and more work while the unit is on line. Response to Interrogatory OCC-177. Documentation submitted by the Company to support this function was largely linked to the Maintenance Rule. Response to Interrogatory OCC-182. The justification submitted consists largely of NRC documentation regarding Maintenance Rule inspections at other nuclear units. The documentation contains numerous references to Maintenance Rule requirements regarding safety risk assessments prior to removing equipment from service while the unit is on line. The NRC found this to be a common weakness at several plants. Id., NRC Information Notice 97-18, Problems Identified During Maintenance Rule Baseline Inspections, pp. 2 and 3. The NRC documentation includes references to utility programs that were implemented to comply with the Maintenance Rule, shows how these programs have evolved over time beyond the scope of the initial Maintenance Rule, and contains statements showing that the NRC endorsed these efforts. Id., Letter dated March 4, 1997, from Joseph Callan to NRC Commissioners, p. 5. The Maintenance Rule has been amended twice since it was issued, last in 1996. Id., p. 7. The picture that develops from this documentation is of an industry struggling to comply with a complex regulation, whose implications were not fully foreseen when initially promulgated. However, it is clear that the Maintenance Rule requires daily vigilance on the part of Company personnel who are familiar with the complex requirements of that rule. This is consistent with the Company’s establishment of a full-time outage management staff. Regardless of the existence of any standard for such a group, this function is clearly not related to the outages at Millstone nor does any party make such a claim.
  2. Page 59 of 191

    Docket No. 98-01-02 The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 28, 2026 OCC- 886 Attachment 1 Page 59 of 191 Page 52 Also, the Department does not believe that the Company should be held to making only those expenditures necessary for minimal compliance with standards. In fact, the Department has found that a culture of minimal compliance was one of the root causes of the decline of Millstone station performance, resulting in the current outages. Tr. 6/27/97 in Docket No. 96-10-06 (Oral Decision), DPUC Investigation into Whether The Connecticut Light and Power Company Fulfilled Its Obligations with Regard to its Nuclear Operations, p. 847. As stated by the Department at that time, “the public and the citizens of Connecticut have a right to expect that the management of a nuclear power plant will always strive for excellence.” Id., p. 856. The Company should certainly not be held to a standard where any expenses beyond those necessary to comply with minimal regulatory standards should be viewed as wasteful, as OCC implies. Also, “industry standards” are sometimes inherently difficult to establish, since they may be set by a common approach to problems that is not codified in any documentation. Often, standards are established and understood by interaction among staff assigned to different nuclear plants. Since the cost associated with Work Planning and Control is not a consequence of the current outage, the Department will allow its inclusion in rates. b. Material Condition Improvement Program The Company is establishing a program that consolidates all painting and coating work into one organization. OCC states that the costs of this program should be disallowed, since they cannot be linked to new or heightened industry standards. Schlissel Testimony, p. 42. Also, the Company had painting and coating programs during the reference 1990-1995 time period, therefore OCC believes the additional cost cannot be justified. Id., p. 43. The Company states that the proposed costs incorporate recent industry experience with coatings at other nuclear power plants and the program achieves greater accountability by consolidating all similar work in one department. Response to Interrogatory OCC-177. The Company provided supporting documentation from the NRC that describes significant deficiencies in the application of coatings at other nuclear power plants. Response to Interrogatory OCC-182. The reported events, from as recently as 1997, highlight the importance of coatings in certain applications, where defects in coatings could have major safety implications. The record shows that industry experience with protective coatings is continually evolving. This is supportive of the Company’s efforts to focus more attention on this area of its nuclear operations. No party claims that the expenses associated with this function are the result of the current outages. As in Section II.F.7.a, above, the Department believes the Company should have the flexibility to operate and maintain its nuclear plants beyond minimal industry standards, and that it is not appropriate to include in rates only those costs required for minimal compliance with industry standards or NRC regulations. Therefore, the Department will allow this program’s costs to be included in rates. c. Commitment Tracking System The Commitment Tracking System function includes expenses for creating a centralized tracking system for all commitments made to the NRC by the Company. Response to Interrogatory OCC-177, p. 3. OCC states that the costs associated with
  3. Page 60 of 191

    Docket No. 98-01-02 The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 28, 2026 OCC- 886 Attachment 1 Page 60 of 191 Page 53 this function should not be allowed, since the system was developed in response to the NRC 10CFR50.54(f) demand for information. Schlissel Testimony, p. 45. The Company provided documents from the NRC and the Nuclear Energy Institute that describe industry standards and NRC expectations for managing NRC Commitments. Response to Interrogatory OCC-182. The documents describe the importance of establishing processes and procedures for controlling commitments made to the NRC. The changes to the Commitment Tracking System improves the Company’s ability to track and maintain future commitments as well as presently existing ones. However, documentation provided by the Company states “The RCD [Regulatory Commitment Database] was developed as part of the response to the 10CFR50.54(f) letter to (1) ensure compliance with the Licensing Basis and (2) establish programs to ensure continued compliance.” Response to Interrogatory OCC-182, Letter dated 5/28/98 from Mario Robles to Walkesl. Since this program was necessitated by the 10CFR50.54(f) demand for information, the program is related to the Millstone outages and the Department will remove its costs from rates. The CL&P portion of the expense for this program is (0.81 * $500,000) [MP2] + (0.53 * $500,000) [MP3] = $670,000. Dente Testimony, Exhibit TJD-1. d. Personal Computer Leasing Program The Company has instituted a program to lease personal computers for employees, instead of buying them. OCC states that the costs associated with this program should not be allowed, since they are not associated with a new or heightened industry standard. Schlissel Testimony, p. 47. The Company states that it is leasing personal computers because it has found it to be more cost effective than purchasing them. Tr. 9/25/98, pp. 2606 and 2607. There has been no claim by any party that leasing personal computers is a result of the Millstone outages. There is no evidence that suggests leasing personal computers is a wasteful use of ratepayer funds, particularly when the alternative to leasing computers is buying them. Similar to Section II.F.7.a, above, the Department will not disallow expenses for the sole reason that they are not necessary to meet industry standards. Therefore, the Department will allow these expenses to be included in rates. e. Consolidation of Information Technology and Support The Company has instituted a program to consolidate all information technology and support functions in one department, to improve administration of these functions and achieve synergies. OCC states that the costs associated with this program should be disallowed, since it is not related to a new or heightened industry standard. Schlissel Testimony, p. 47. There has been no claim by any party that the consolidation of information technology functions is a result of the Millstone outages. Consolidation of these similar functions should result in long-term cost savings. Again, the Department will not disallow expenses for the sole reason that they are not necessary to meet industry standards. Therefore, the Department will allow these expenses to be included in rates.
  4. Page 61 of 191Match

    Docket No. 98-01-02 f. The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 28, 2026 OCC- 886 Attachment 1 Page 61 of 191 Page 54 Non-capital Plant Modifications Non-capital modifications (NCMs) are low-cost changes to plant that are treated as expense items. The Company’s initial filing included $11,800,000 for NCMs at MP2 and $930,000 at MP3, on a whole-unit basis. Dente Testimony, Exhibit TJD-1. The CL&P portions of these amounts are $9,558,000 and $493,000, respectively. The Company stated that these amounts were based on historical experience adjusted for known commitments to the NRC. Response to Interrogatory EL-1. The Company subsequently revised its expectations for 1999 NCMs when the projects were identified and submitted a list of the projects on October 29, 1998. The NCM amounts on a total unit basis are $2,720,000 for MP2 and $8,850,000 for MP3. Response to Interrogatory EL-1, Supplement 1. The CL&P portions of these amounts are $2,203,000 and $4,691,000, respectively. NCM expenses for the three years prior to the Millstone outages, 1993-1995, averaged $3,200,000 for MP2 and $9,700,000 for MP3. Response to Interrogatory EL-354. The proposed NCM amounts are consistent with historical expenses. The expense items are typical of small modifications that occur throughout the life of a nuclear plant. Therefore, the Department accepts the revised amounts and decreases the original MP2 amount by $7,355,000 and increases the original MP3 amount by $4,198,000, for a net reduction of $3,157,000. g. Calculation Tracking System The Company’s filing includes expenses for a new system for tracking calculations, which eases the retrieval of the calculations when a future need arises to access them. Previously, calculations were not comprehensively tracked on a centralized computer system. Response to Interrogatory OCC-177, Supplement 1, Bulk p. 5. OCC states that the costs associated with this program should not be allowed, since the program is not related to industry standards and is a result of the NRC 10CFR50.54(f) order that resulted in the Millstone outages. Schlissel Testimony, pp. 55 and 56. However, OCC did not cite any evidence supporting this position. The system is intended to be used on a going-forward basis to ensure future calculations are properly tracked. This should result in improved efficiencies by reducing the administrative burden of retrieving calculations from diverse locations. Tr. 9/25/98, pp. 2623-2625. Again, the Department will not disallow expenses for the sole reason that they are not necessary to meet industry standards. Therefore, the Department will allow these expenses to be included in rates. h. Material Equipment Parts List The Material Equipment Parts List (MEPL) is a database of plant components that contains information important to the maintenance of that equipment. Response to Interrogatory OCC-177, Supplement 1, p. 7. The Company’s filing includes incremental expenses for completing the MEPL. The changes to the MEPL include adding components and increasing efficiencies in the procurement and storage of replacement parts. Response to Interrogatory OCC-182, Supplement 2, Maintenance of Material Equipment Parts List. OCC states that expenses associated with this program should
  5. Page 62 of 191

    Docket No. 98-01-02 The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 28, 2026 OCC- 886 Attachment 1 Page 62 of 191 Page 55 not be allowed, since the Company has not identified new or heightened industry standards associated with this program; rather, it is necessary to remedy “deficiencies.” Schlissel Testimony, p. 58. There is no evidence that the MEPL improvements are related to the Millstone outages. They are enhancements to an existing program. Since safety grade components cost considerably more than non-safety grade ones, the enhancements should result in long-run savings by elimination of the practice of procuring non-safety grade components that were previously classified as safety grade. Again, the Department will not disallow expenses for the sole reason that they are not necessary to meet industry standards. Therefore, the Department will allow these expenses to be included in rates. i. Implementation of Condition Based Maintenance The Company’s filing includes expenses for the addition of an Integrated Preventive Maintenance Program (IPMP) and an Equipment Effectiveness Training Program (EETP). These programs were implemented to develop methods for trending and monitoring performance for common component failures. The Company states that these programs will improve equipment reliability over time. Response to Interrogatory OCC-177, Supplement 1, p. 8. OCC states that the costs associated with the IPMP and EETP should not be allowed, since the Company has not identified new or heightened industry standards associated with them. Schlissel Testimony, p. 59. Documentation provided by the Company states that these programs were designed by consultation with other nuclear industry participants to identify characteristics of successful programs in this area. Response to Interrogatory OCC-178, Supplement 2, Equipment Effectiveness Trending - Best Practices Initiative, p. 3. Therefore, evidence supports the claim that these programs were implemented to meet industry standards. There is no evidence that the IPMP and EETP are related to the Millstone outages. They are improvements of an existing program. Therefore, the Department will allow these expenses to be included in rates. 8. Devon Station Gas Turbines The Devon Station O&M costs are $11.823 million, including lease payments of $9.6 million, for the rate year. June 30, 1998, Supplemental Filing, Devon Station O&M; Tr. 9/15/98, pp. 1055 and 1056; Late Filed Exhibit No. 92. As concluded in Section II.E.1.c, above, the gas turbines were added solely due to the Millstone outages. Therefore, the Department reduces expenses by $11.823 million.
  6. Page 63 of 191

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 28, 2026 OCC- 886 Attachment 1 Page 63 of 191 Docket No. 98-01-02 9. Page 56 Decommissioning The Company filed the latest decommissioning studies for MP1, 2, and 3. The proposed method of decommissioning is immediate dismantlement (single unit DECON) for each unit. The estimated cost of decommissioning in 1997 dollars is $481,800,000 for MP1; $430,900,000 for MP2; and $519,400,000 for MP3. By comparison, the DECON cost estimates the Company submitted in Docket No. 92-11-11 were $350,864,000 for MP1; $281,798,000 for MP2; and $383,175,000 for MP3. The NRC requires each nuclear plant owner to calculate a minimum decommissioning cost per Title 10 of the federal Code of Regulations,10CFR50.75(c). The NRC also requires the owner to fund decommissioning for at least this amount, regardless of the amount determined by the site specific study. The amount is determined by a prescribed formula in 10CFR50.75(c) and adjusted by escalation factors for labor, energy, and radioactive waste burial charges. The labor and escalation factors are required to be derived from U.S. Department of Labor Statistics data, and the radioactive waste burial factor must be derived from NUREG-1307, “Report on Waste Burial Charges.” 10CFR50.65(c)(2). These amounts in 1997 dollars are calculated as $512,000,000 for MP1; $460,000,000 for MP2; and $488,000,000 for MP3. Levy Testimony, p. 21. The following chart shows the decommissioning amounts for each unit. Decommissioning Amounts (in $thousands) MP1 MP2 MP3 92-11-11 DECON 350,864 281,798 383,175 98-01-02 DECON 481,800 430,900 519,400 NRC Minimum 512,000 460,000 488,000 Proposed 512,000 460,000 519,400 The DECON cost estimates were developed by TLG Engineering, Inc. using the latest cost estimating methodologies and are based on site-specific studies for each unit. Each estimate reflects the present cost of decommissioning under current requirements using available technology. Levy Testimony, pp. 11 and 12. The DECON estimates also include a contingency factor to reflect possible schedule delays due to unforeseeable events such as equipment breakdowns. The contingency factors are assigned to individual activities based on the uncertainty associated with that activity. The overall contingency factors for each unit are 19.7% for MP1, 18.6% for MP2, and 19.0% for MP3. By comparison, in Docket No. 92-11-11 the DECON estimates included contingency factors of 15.95% for MP1, 16.18% for MP2, and 16.00% for MP3. The Company states that the changes in contingency factors are based on industry experience with decommissioning and related issues such as radioactive waste disposal costs. Tr. 9/25/98, p. 2670. The Company proposes to base the decommissioning collections on the NRC minimum amounts for MP1 and 2, and the site-specific amount for MP3. For each unit, the amount requested is the greater of the NRC minimum or the site amount. In the
  7. Page 64 of 191

    Docket No. 98-01-02 The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 28, 2026 OCC- 886 Attachment 1 Page 64 of 191 Page 57 case of MP1 and 2, the amount requested is based on regulatory requirements and is not subject to potential inaccuracies in assumptions such as contingency or future radioactive waste disposal costs. Therefore, the Department concludes that the proposed amounts for MP1 and 2 are reasonable and approves them as filed. The Company proposes to base its decommissioning collection for MP3 on the site-specific DECON study amount of $519,400,000, which is $31,400,000 more than the NRC minimum amount. The Company states that the site-specific cost estimate is greater than the NRC minimum due to features peculiar to MP3 that differ from the unit on which the minimum calculation is based. Levy Testimony, p. 21. The cited differences include design, siting, and access to radioactive waste disposal sites. Response to Interrogatory EL-27. In its decommissioning estimates, the Company includes the cost of removing non-radioactive structures and components. However, the NRC does not require the costs of removing this material to be included in decommissioning cost estimates, and, in fact, specifically excludes them from its regulations regarding decommissioning. Response to Interrogatory EL-16. The Company states these costs should be included in the cost estimates, since they are legitimate business costs that will be incurred in the future. Tr. 9/25/98, pp. 2655 and 2656. The total estimated cost of non-radioactive material removal at MP3 is $71,189,000. Response to Interrogatory EL-18. This amount includes removal of a technical building, and the training/simulator building. Tr. 9/25/98, p. 2673. Both these buildings could have value after the units are decommissioned, since they do not contain any radioactive contamination and could be used for another purpose. This is particularly true of the technical building, which was constructed in 1994. Decision dated May 5, 1994, in Docket No. 93-09-04, Application of Northeast Nuclear Energy Company, The Connecticut Light and Power Company and Western Massachusetts Electric Company for Approval to Finance the Construction of a Technical Building at the Millstone Nuclear Generating Units, p. 9. Including the cost of removing non-radioactive material in decommissioning cost estimates involves issues of equity between nuclear and non-nuclear generating facilities, since non-nuclear facilities do not benefit from prefunding of dismantling costs. This is not equitable to those facilities since, given pending deregulation of electric generation, those facilities will not have a mechanism to recover these costs, but nuclear facilities would. The Department therefore believes the decommissioning cost estimates should only reflect those costs that the NRC requires to be prefunded. Since the NRC only requires radioactive material removal costs to be prefunded, the Department will not consider the cost of removing non-radioactive material in the decommissioning cost estimates. In the case of radioactive materials, there are clear regulatory and public safety issues that mandate funding of these costs. Subtracting the non-radioactive material removal cost from the total MP3 decommissioning cost yields a total radioactive material remediation cost of $448,211,000. This is below the NRC minimum decommissioning amount of $488,000,000. Since the NRC requires this amount to be prefunded, the Department will allow decommissioning collections to be based on this amount. The Department will therefore order the Company to reduce MP3 decommissioning collections to reflect the
  8. Page 65 of 191

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 28, 2026 OCC- 886 Attachment 1 Page 65 of 191 Docket No. 98-01-02 Page 58 NRC minimum, reducing revenue requirements from $9.35 million to $8.42 million, a reduction of $930,000. a. Nuclear Decommissioning Financing The calculation of nuclear decommissioning funding requirements for 1999 and over the life of the nuclear decommissioning trusts requires assumptions about the earnings, schedule of contribution levels, tax rates, cost escalation rates, as well as estimates of the current cost of decommissioning. Each Millstone plant has two decommissioning trust funds, a “qualified” (tax-deductible) and a “non-qualified” (non-tax deductible), to finance its nuclear decommissioning. CL&P contributes its pro rata share of funds, which are deposited into each trust fund on a monthly basis. MP2 and 3 trust funds have investment allocations of 40% equity and 60% fixed income securities, while the MP1 trust fund, with a shorter decommissioning time horizon, has asset allocations of 30% equity and 70% fixed income securities. At the end of the time horizon for each of the trusts, the time period when the majority of the funds will be spent, the percentage of assets invested in equity will be reduced by 5% per year until all of the equity investments have been phased out. Response to Interrogatory EL-395. The assumed rates of return for the trusts’ assets are as follows: Equity: Fixed income: Taxable Tax exempt ` 9.5% 6.0% 4.5% Source: Response to Interrogatory EL-395 The expected return of 9.5% on equity was developed using information on current returns and expected long-term returns on stocks. The 6.0% expected return on bonds is the average yield on the bond market as a whole, as measured by the Lehman Aggregate Index. The tax exempt rate of 4.5% was obtained by taking 75% of the average yield on taxable bonds, which reflects the ratio of the returns of tax-exempt compared to taxable fixed securities. Response to Interrogatory EL-399. These rates of return would result in a weighted average before-tax assumed return on assets of approximately 6.53% for the MP1 trust and 6.95% for the MP2 and 3 trusts. Response to Interrogatory EL-395; Tr. 9/25/98, pp. 2689-2691. Recent returns on assets of the trusts for MP1, 2 and 3, 1992 through 1997, have averaged a before tax return of approximately 10.2%.4 The Company also submitted escalation rates for materials, labor and energy, which have average long-term growth rates of 2.1%, 4.1%, and 3.6%, respectively. Response to Interrogatory EL-393, p. 2. The Department finds these escalation rates to be reasonable. The Company has used assumed rates of return on equity and fixed assets that are less than the actual earned rates for the years 1992 through 1997; however, the Department finds the assumed rates to be reasonable for the long term. Although the 4 Averages for the Millstone Units trusts are unweighted.
  9. Page 66 of 191

    Docket No. 98-01-02 The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 28, 2026 OCC- 886 Attachment 1 Page 66 of 191 Page 59 Department reduces the 1999 decommissioning collections for MP3 by $930,000, as described in Section II.F.9, above, the magnitude of this change in 1999 costs does not warrant a revision in the assumed earnings and future collections in the MP3 trust to reflect this cost reduction. 10. Nuclear Final Materials and Supplies Expense The Company requests that the Department approve $1.428 million for amortization of final M&S. Response to Interrogatory OCC-232, p. 2. The final M&S value is based on the M&S on hand on 12/31/97. Tr. 9/15/98, p. 1111. This is the first time the Company has sought inclusion of this item in rates. Pursuant to the Act, nuclear units will not be subject to rate regulation after January 1, 2004. The Company’s operational nuclear units are expected to continue running until at least the year 2015, the license expiration date for MP2. Response to Interrogatory OCC-86, p. 4. Therefore, at the time the M&S expenses are incurred, the units will not be subject to rate regulation. The Company is requesting that the Department allow an expense in regulated rates that will be incurred in a deregulated market. It is not appropriate to recover these costs through rates, absent a significant public policy determination to do so. Also, there is no reason to speculate as to the value of the final core and M&S since this amount will be reflected in the price paid for the units when they are sold, and ultimately included in the calculation of stranded cost. Therefore, the Department will disallow this expense, reducing expense by $1.428 million. 11. MP Unit 1 Administrative and General Expenses Due to the early retirement of MP1, CL&P forecasts O&M expense savings of $111.4 million in 1999. Late Filed Exhibit No. 6, AR-OCC-34. The Company did not include $5.6 million of administrative and general (A&G) expense savings associated with the MP1 retirement in the O&M expense savings. Tr. 9/17/98, pp. 1427-1429; Late Filed Exhibit No. 168, Read-In W. PRO and OCC believe that the Department should remove $5.6 million from the rate year. PRO Brief, p. 9; OCC Brief, p. IV-30. The Department does not agree with PRO and OCC that it is appropriate to remove the A&G expense savings from the rate year. The Company cleansed the rate year of MP1 expenses in Schedule C-2. Therefore, any savings the Company may realize from the retirement do not affect the rate year. 12. Maine Yankee The Company has included expenses in the rate year for its contractual payments to Maine Yankee (MY) based on its ownership percentage. The components of the payments are O&M, Department of Energy Decontamination and Decommissioning (DOE D&D) costs, amortization of nuclear fuel final core and M&S, depreciation, taxes, decommissioning, and a return on the unrecovered investment balance. Response to Interrogatory EL-211. MY currently has a proceeding before the Federal Energy Regulatory Commission (FERC) to determine the rates it may charge its
  10. Page 67 of 191Match

    Docket No. 98-01-02 The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 28, 2026 OCC- 886 Attachment 1 Page 67 of 191 Page 60 owners, including CL&P. Response to Interrogatory OCC-189. FERC precedent is to establish rates subject to refund. Tr. 9/14/98, p. 950. In the event FERC decides the rates charged by MY are too high or if any components of the rates are denied because of imprudence, CL&P would receive credits or refunds, which it would apply to the account where the costs were initially recorded. Because the Application does not contain any credits, they will flow directly to the financial statements and the bottom line, not to ratepayers. However, the Company could defer the refunds for future disposition to ratepayers. Response to Interrogatory OCC-335; Tr. 9/14/98, pp. 951, 952 and 957. Because FERC has jurisdiction to set the rates CL&P must pay MY, the Department will allow the MY costs to be passed on to ratepayers. However, the Department leaves open the possibility of refunding MY costs to ratepayers that are disallowed by FERC. The Department will order CL&P to create an account to record refunds or credits it receives from MY. The Department will consider the disposition of refunds or credits by reopening this docket or in a future rate proceeding. 13. C&LM Bonus Incentive As discussed in Section II.E.7, above, the Department eliminates the CAM for 1999. Traditionally, CL&P is awarded a bonus incentive of up to 3% of average rate base, based on the cost effectiveness of its C&LM programs, as a means of promoting C&LM. A target incentive is calculated each year and then trued up in following years based upon the actual cost effectiveness of the C&LM programs. The Company is concerned that there could be some true-ups from prior years that might not have been taken care of without the CAM. Tr. 9/14/98, p. 922. However, the Company is never guaranteed it will receive a bonus because the cost effectiveness of the C&LM programs could fall below expectations. The Department allows a 2% bonus incentive for 1999 applied to 1999 C&LM expenditures instead of rate base, because the 1999 rate base will be extremely small. This equals $575,000 ($28.752 million x .02). This gives the Company a reasonable incentive to pursue C&LM for 1999 and should allay the Company’s concerns about prior years true-ups as well as the true-up for 1999. 14. Electric Power Research Institute The Electric Power Research Institute (EPRI) provides extensive research and development (R&D) services to the electric utility industry. In recent years it has expanded membership eligibility to all organizations in the evolving energy field, including the generation, delivery and sale of electricity, related services and other energy suppliers. EPRI also has taxable subsidiaries, EPRICSG, Inc. and EPRIGEN, Inc., which were created to meet new and emerging needs of an increasingly competitive energy industry, while maintaining EPRI’s historical, tax-exempt mission to perform R&D in the public interest. Late Filed Exhibit No. 6, AR-OCC 55. At the present time, many technological changes are being introduced in the electric industry and many more are in the developmental stages. EPRI’s R&D results

As listed on the current system