Interrogatory responses
Answers to questions 21, 22
Files16
EOE-021_final.pdf
PDF · 89 KB · 1 pageText searchable
Download EOE-021_final.pdfRead the text of EOE-021_final.pdf
EOE-021 Attachment 1.pdf
PDF · 97 KB · 1 pageText searchable
Download EOE-021 Attachment 1.pdfRead the text of EOE-021 Attachment 1.pdf
EOE-021 Attachment 1.xlsx
Excel · 23 KBText searchable
Download EOE-021 Attachment 1.xlsxRead the text of EOE-021 Attachment 1.xlsx
EOE-022_final.pdf
PDF · 118 KB · 2 pagesText searchable
Download EOE-022_final.pdfRead the text of EOE-022_final.pdf
EOE-022 Attachment 01.pdf
PDF · 4.7 MB · 63 pagesText searchable
Download EOE-022 Attachment 01.pdfRead the text of EOE-022 Attachment 01.pdf
EOE-022 Attachment 02.pdf
PDF · 1.2 MB · 16 pagesText searchable
Download EOE-022 Attachment 02.pdfRead the text of EOE-022 Attachment 02.pdf
EOE-022 Attachment 03.pdf
PDF · 1.0 MB · 9 pagesText searchable
Download EOE-022 Attachment 03.pdfRead the text of EOE-022 Attachment 03.pdf
EOE-022 Attachment 04.pdf
PDF · 1.4 MB · 11 pagesText searchable
Download EOE-022 Attachment 04.pdfRead the text of EOE-022 Attachment 04.pdf
EOE-022 Attachment 05.pdf
PDF · 1.2 MB · 14 pagesText searchable
Download EOE-022 Attachment 05.pdfRead the text of EOE-022 Attachment 05.pdf
EOE-022 Attachment 06.pdf
PDF · 6.4 MB · 45 pagesText searchable
Download EOE-022 Attachment 06.pdfRead the text of EOE-022 Attachment 06.pdf
EOE-022 Attachment 12.pdf
PDF · 6.4 MB · 45 pagesText searchable
Download EOE-022 Attachment 12.pdfRead the text of EOE-022 Attachment 12.pdf
EOE-022 Attachment 11.pdf
PDF · 1.2 MB · 14 pagesText searchable
Download EOE-022 Attachment 11.pdfRead the text of EOE-022 Attachment 11.pdf
EOE-022 Attachment 10.pdf
PDF · 1.4 MB · 11 pagesText searchable
Download EOE-022 Attachment 10.pdfRead the text of EOE-022 Attachment 10.pdf
EOE-022 Attachment 09.pdf
PDF · 1.0 MB · 9 pagesText searchable
Download EOE-022 Attachment 09.pdfRead the text of EOE-022 Attachment 09.pdf
EOE-022 Attachment 08.PDF
PDF · 1.2 MB · 16 pagesText searchable
Download EOE-022 Attachment 08.PDFRead the text of EOE-022 Attachment 08.PDF
EOE-022 Attachment 07.pdf
PDF · 4.7 MB · 63 pagesText searchable
Download EOE-022 Attachment 07.pdfRead the text of EOE-022 Attachment 07.pdf
Text of EOE-022_final.pdf
Extracted from the file · 2 pages · 4,484 characters
Text of EOE-022 Attachment 01.pdf
Extracted from the file · 63 pages · 39,373 characters
Text of EOE-022 Attachment 02.pdf
Extracted from the file · 16 pages · 23,984 characters
Text of EOE-022 Attachment 03.pdf
Extracted from the file · 9 pages · 21,996 characters
Text of EOE-022 Attachment 04.pdf
Extracted from the file · 11 pages · 22,363 characters
Text of EOE-022 Attachment 05.pdf
Extracted from the file · 14 pages · 20,678 characters
Text of EOE-022 Attachment 06.pdf
Extracted from the file · 45 pages · 22,564 characters
Text of EOE-022 Attachment 12.pdf
Extracted from the file · 45 pages · 22,609 characters
Text of EOE-022 Attachment 11.pdf
Extracted from the file · 14 pages · 20,693 characters
Text of EOE-022 Attachment 10.pdf
Extracted from the file · 11 pages · 22,374 characters
Text of EOE-022 Attachment 09.pdf
Extracted from the file · 9 pages · 21,993 characters
Text of EOE-022 Attachment 08.PDF
Extracted from the file · 16 pages · 23,984 characters
Page 14 of 63
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set EOE-01 Date Issued July 31, 2026 EOE-022 Attachment 7 Page 14 of 63 Contractor onboarding VIRTUAL PROCESS • Each non-Eversource crew member (contractor and outside utility) is required to be on-boarded prior to the start of restoration work. • The General Foreman or Foreman/Lead assigned to crews for the contractor and/or outside utility will be responsible for taking applicable safety onboarding and disseminating the information to their assigned crews. • Existing contractor crew leads already on Eversource property prior to a storm event (for example, Contractors of Choice (COC)), require a formal on-boarding that is valid for one (1) year. • Formal on-boarding for a non-COC, as well as Foremen/Leads from a COC company but traveling from an area outside our service territory (CT/MA/NH), are valid for six (6) months. • Aggregator companies (i.e. Parent companies that hire subsubcontractors to work under the Parent Name), shall ensure that the Foreman/Leads from the hired companies complete the onboarding and acknowledgement form. • Eversource requires that the name on a company truck matches with the name given on the acknowledgement form. External Resource Field Coordinator Training - SafetyPage 15 of 63
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set EOE-01 Date Issued July 31, 2026 EOE-022 Attachment 7 Page 15 of 63 Transmission & Distribution Contractors (with an active MSA) Contractor Connecticut (CT) Eastern Massachusetts (EMA) Western Massachusetts (WMA) New Hampshire (NH) Aldridge Electric, Inc. Asplundh Construction Corp. ATL Construction, Inc. Aztec Energy, Inc. Blakeslee Arpaia Chapman, Inc. BluRoc, LLC Bond Brothers, Inc. Central Connecticut Cable Co Inc Charter Oak Utility Constructors Inc Cianbro Corporation CJ Drilling, Inc. Conexus Energy Group LLC Creative Surveying LLC D and D Power, Inc. E. S. Boulos Company East Coast Power LLC EJ Electric Installation Co Fairway Electric Inc. Ferreira UTEC, LLC G Greene Construction Co Inc. Grattan Line Construction Corp H. I. Stone & Son Inc Harlan Electric Co Haugland Energy Group LLC Hutter Construction Corporation I C Reed & Sons Inc I.B. Abel, Inc. Infrasource Construction LLC JCR Construction Co Inc JHD Corporation Lawrence Lynch Corp. M J Electric LLC Manafort Brothers Inc. Mass Bay Electrical Corp. Matrix North American Construction, Inc. X X X X X X X X X X X X McCourt Construction Co. Inc. McPhee Electric LTD LLC Michels Power, Inc. MTV Solutions Inc. Nooter Utility Services Northline Utilities, LLC One Source Power, LLC Orion Utility Contractors, LLC P&G Power Corp. Power Line Contractors, Inc. Riggs Distler & Company Inc. Right of Way Solutions, LLC Sargent Electric Company Squan Construction Services, LLC State Electric Corporation Suffolk Construction Company, Inc. Supreme Industries, Inc. The Middlesex Corporation Three Phase Line Construction Inc United Civil, LLC Utility Service & Assistance Inc. Valiant Energy Service LLC W. A. Chester LLC Witch Enterprises Inc X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X External Resource Field Coordinator Training - Safety 15Page 16 of 63
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set EOE-01 Date Issued July 31, 2026 EOE-022 Attachment 7 Page 16 of 63 Eversource External Mutual Aid Safety Onboarding Guide External Resource Field Coordinator Training - Safety 16Page 17 of 63
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set EOE-01 Date Issued July 31, 2026 EOE-022 Attachment 7 Page 17 of 63 Eversource External Mutual Aid Safety Onboarding Guide Worker Responsibilities: Comply with required federally mandated OSHA requirements and to the normal safety practices and policies of your home organizations. Rubber Gloves and Sleeves Requirements: • Minimum of Class II high voltage rubber gloves and rubber sleeves (or higher rated gloves and sleeves dependent upon the nominal system voltage exposures) are required to be worn at all times whenever an employee is exposed to conductors which may be energized or become energized (between 50 Volts to 35,000 Volts) while working aloft (i.e., aerial device, climbing, the Ground to Ground/Cradle to Cradle Rule). Any deviations must be approved by the Eversource Director of Safety or designee. Eversource Information Transfer Policy: OSHA requires Eversource and contractors to exchange information on known hazards and on the existing conditions, characteristics, design, and operation of Eversource’s installation. Eversource transfers this information through the External Contractor Mutual Aid Safety Briefing. External Resource Field Coordinator Training - Safety 17Page 18 of 63
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set EOE-01 Date Issued July 31, 2026 EOE-022 Attachment 7 Page 18 of 63 Eversource External Mutual Aid Safety Onboarding Guide Daily Safety Messages: All crew supervisors are expected to communicate the messages to their crews before the start of each workday. ES Storm Safety Briefing will be shared through e-mail. External Resource Field Coordinator Training - Safety 18Page 19 of 63
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set EOE-01 Date Issued July 31, 2026 EOE-022 Attachment 7 Page 19 of 63 Eversource External Mutual Aid Safety Onboarding Guide E-911 Information: – – – KNOW YOUR EXACT LOCATION BEFORE STARTING WORK. Notify crew leader and workers about allergies, medications, and medical conditions. Ensure your supervisor has local storm room phone number and name and address of all local medical facilities. External Resource Field Coordinator Training - Safety 19Page 20 of 63
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set EOE-01 Date Issued July 31, 2026 EOE-022 Attachment 7 Page 20 of 63 Eversource External Mutual Aid Safety Onboarding Guide Conduct Documented Job Briefings: – – – Before each job and when the scope of the job changes; include all personnel at site. Discuss hazards associated with job, work procedures, special precautions, energy source control, PPE, other crews in the area, emergency procedures. The documented Job Safety Briefing must be readily available at the jobsite. External Resource Field Coordinator Training - Safety 20Page 21 of 63
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set EOE-01 Date Issued July 31, 2026 EOE-022 Attachment 7 Page 21 of 63 Eversource External Mutual Aid Safety Onboarding Guide System Voltages: Grounded Wye, Unigrounded Wye, and Delta Primary Circuits – Each business entity within Eversource has its own distribution system voltage safety requirements and design considerations. Ask your owners representative and/or bird dog for circuit voltages and arc flash potential. ES PRIMARY DISTRIBUTION VOLTAGES PER COMPANY Company New E W Voltage Connecticut Hampshire Massachusetts Massachusetts 2,300 V Delta 2,160/3,740 V X X 2,400/4,160 V X X X X 4,800/8,320 V X X X X 4,800/8,320 V X Delta 7,200/12,470 V X 7,620/13,200 V X X 7,967/13,800 V X X X X 11,450 V X 13,200/22,860 V X X X 14,000/24,940 V X X 19,920/34,500 V X X X 26,558/46,000 V X 27,600 V Delta X External Resource Field Coordinator Training - Safety 21Page 22 of 63
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set EOE-01 Date Issued July 31, 2026 EOE-022 Attachment 7 Page 22 of 63 Eversource External Mutual Aid Safety Onboarding Guide PPE: – – – – – – – Comply with required federally mandated OSHA requirements and to the normal safety practices and policies of your home organizations. All personnel on site must wear appropriate PPE High Visibility Traffic Vest (Class III) Hard Hat Safety Glasses EH Safety Footwear FR Clothing External Resource Field Coordinator Training - Safety 22Page 23 of 63
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set EOE-01 Date Issued July 31, 2026 EOE-022 Attachment 7 Page 23 of 63 Eversource External Mutual Aid Safety Onboarding Guide PPE Continued: Rubber Gloves and Sleeves Requirements: • Minimum of Class II high voltage rubber gloves and rubber sleeves (or higher rated gloves and sleeves dependent upon the nominal system voltage exposures) are required to be worn at all times whenever an employee is exposed to conductors which may be energized or become energized (between 50 Volts to 35,000 Volts) while working aloft (i.e., aerial device, climbing, the Ground to Ground/Cradle to Cradle Rule). Any deviations must be approved by the Eversource Director of Safety or designee. • Handling of any normally energized primary conductors from the ground shall be performed with a live-line tool, unless the primary conductors are effectively grounded and a minimum of Class II gloves are worn. Secondary conductors shall be handled from the ground with a minimum of Class 2 rubber gloves. • Workers performing any switching (aloft or at ground level) using a live line tool and/or when performing stick work (hot sticking work aloft) at 34.5kV or below requires a minimum of Class II rubber gloves (and rubber sleeves while working aloft during Storm Restoration ****). External Resource Field Coordinator Training - Safety 23
As listed on the current system
Question(s) Answered 21, 22 (CL&P dba Eversource Energy) Date Filed: 08/14/2026