Skip to main content

A prototype public docket site for the Connecticut Public Utilities Regulatory Authority

Utility Dockets and Filings

Interrogatory responses

Answers to questions 259, 260

ResponseFiled by Connecticut Light and Power Company dba Eversource Energy14 files
Part of docket 26-05-10Open
  • Electric
Application of The Connecticut Light and Power Company d/b/a Eversource Energy to Amend its Rate Schedules

Files14

  1. Page 201 of 214

    The Connecticut Light and Power Company d/b/a Eversource Energy REDACTED Docket No. 26-05-10 Date Issued September 11, 2026 EOE-259 Attachment 3 REDACTED Page 201 of 214 *Length of service in the Department since date of last employment by the Company shall constitute Department seniority. Response Specialist Staffing • Internal Candidates – Hiring process in accordance with contractual provisions. • External Candidates – Potential candidates to be given a physical skills assessment. Successful candidates to be offered a position within the Response Specialist organization. Candidates who accept a position will receive training/orientation prior to beginning their new role. External hires will start at the minimum RSO rate and be held at that rate through their probationary period in accordance with the contract. Retention Initial incumbent qualified employees who elect to accept a position within the Response Specialist classification will be retained for a period of two (2) years from date of transfer and will not be entitled to apply for posted job openings during this period. Exceptions to this two year restriction would be promotions attained through the employee’s normal sequence of progression. The initial incumbent employees, who wish to return to their respective districts and classifications, must notify RSO management in writing, at least thirty days prior to their intention to leave the Response Specialist organization. However, an adequate complement of Response Specialists must be maintained to operate the Response Specialist organization. Therefore, an incumbent employee will not be released if the complement would be below a certain threshold, set forth in Attachment D. The Response Specialist reclassified to their previous classification will not be required to accept upgrade to the Response Specialist for a period of two (2) years. All others, subsequent to the initial posting, once qualified as a Response Specialist, will remain in the position for a minimum of three (3) years and will not be entitled to apply for posted job openings outside of the RSO during this period. The junior qualified employee(s) by Teal Book seniority in the affected Local 420 or Local 457 territory will be required to accept any unfilled vacancies in the Response Specialist classification. Incumbent employees forced into the Response Specialist position will be retained for a minimum of eighteen (18) months. An employee who is forced into the Response Specialist classification for a minimum of eighteen (18) months will not be required to accept upgrade to the Response Specialist classification for a period of one (1) year starting from the date of being released from the organization. Exceptions to this eighteen (18) month retention period restriction would be promotions attained through the employee’s normal sequence of progression. Seniority: For the purposes of Article V, Section 2 (a) only, Response Specialist and Line Mechanic will be considered as the same classification. 195
  2. Page 202 of 214

    The Connecticut Light and Power Company d/b/a Eversource Energy REDACTED Docket No. 26-05-10 Date Issued September 11, 2026 EOE-259 Attachment 3 REDACTED Page 202 of 214 In addition, during the initial two (2) year startup period, Response Specialists formerly classified as a Lead or Chief Line Mechanic will be treated as a Lead or Chief Line Mechanic respectively for the purposes of Article V, Section 2 (a) only. All initial incumbent employees who chose to remain in the RSO following the two (2) year startup period will have their classification seniority date adjusted to the implementation date for Zone 1. The Response Specialist position requires a minimum qualification of Line Mechanic for at least one (1) year prior to the date of transfer or forcing. Implementation: Post and fill initial Response Specialist positions upon June 1, 2016 contract ratification. Upgrading: When the Company assigns three (3) or more people to a crew, the Company will designate an employee to direct the workforce and be responsible for the crew for all hours so assigned on that day provided the assignment is for one (1) or more hours. The designated employee in charge will be paid per hour in addition to the employee’s basic straight time hourly rate for all hours so assigned. Upgrading will normally be on a classification seniority basis. Meals: Any earned meals will be paid at the contractually higher rate . Meal time not taken shall not count as hours worked for the purposes of determining sixteen hours of work or rest time in accordance with Article VI, Sections 6 and 7. Rest Time: Except in case of emergency or the case of unforeseen absence of other employees, employees shall not be required to work more than sixteen hours in any one twenty-four hour period. The rest time window set forth in Article VI, Section 6 does not apply to Response Specialist employees. A Response Specialist must work beyond 16 hours in any 24 hour period, not including meal time not taken, in order to be allowed 8 hours off, once released, before returning to work. If this period extends into the employee’s regular scheduled working hours, the employee shall lose no pay thereby. Planned Overtime: Planned overtime shall be defined as overtime work for which at least forty-eight hours advance notice has been given and will be assigned among employees as equally as possible. Effective June 1, 2020, the planned overtime notice will be reduced from forty-eight hours to thirty-six hours. Effective June 1, 2021, the planned overtime notice will be reduced from thirty-six hours to twenty-four hours. If a Response Specialist accepts a planned overtime shift, the Response Specialist cannot accept a call out prior to the planned overtime shift that would preclude him or her from filling the initial planned overtime shift. 196
  3. Page 203 of 214

    The Connecticut Light and Power Company d/b/a Eversource Energy REDACTED Docket No. 26-05-10 Date Issued September 11, 2026 EOE-259 Attachment 3 REDACTED Page 203 of 214 A Response Specialist cannot accept a planned overtime shift prior to his or her regular shift if taking such planned overtime will make the employee unavailable to work all of his or her regular shift. Attachment A Eversource Response Specialist Duties The responsibilities will include, but not be limited to, clearing faulty and unsafe conditions, including maintaining or restoring electrical service, by temporary or permanent means to include replacing or bracing/lashing poles, securing pole tops, floating conductors, extending secondary, or as described in the below listed duties. The below illustrative duties will be performed as a single-person crew or as a multiperson crew as dictated by the task and applicable work methods. 1. Clearing faulty and unsafe conditions including maintaining or restoring electrical service by temporary or permanent means; 2. Operate primary* and secondary fault locating equipment on URD systems in order to isolate the faulted equipment and restore the customers. This includes all URD/DB single phase systems and three phase radials; 3. Operate switching and control devices on both the overhead and underground systems (pad mounted equipment). See Attachment B for further information; 4. Connect, disconnect, and operate portable transformers and temporary primary jumpers under emergency or urgent conditions; 5. Replace failed transformers with assistance of other qualified employee(s); 6. Replace damaged or faulty equipment during the initial response; 7. Perform street light repair work including replacing defective bulbs, photocells, and heads along with new installations (up to a 250 watt head and under a 12’ bracket); 8. Install and remove minimal cover up as needed. This may include primary conductors; 9. Perform secondary overhead and URD service connections associated with connecting customers; 10. Perform overhead distribution system line patrols; 11. Perform URD and overhead equipment inspections; 12. Make current and voltage measurements, as required; 13. Determine and record causes of failures and communicate the findings to the SOC; 14. Communicate the status of outages to the SOC – on-site, restoration projections, ETRs, etc.; 15. Investigate customer concerns, communicate with customer when needed to provide information; 16. Investigate and correct complaints of interference to telephone, radio, or television reception; 17. Document and submit required records and reports associated with trouble, line patrols, equipment inspections, and other related work; 18. Utilize mobile data terminals as instructed; 19. Operate GOABs that Line Mechanics operate (excluding GOABs with keyed interlock systems), reclosers and cutouts when needed, as well as other equipment that Line Mechanics currently operate; 20. External substation inspections. 197
  4. Page 204 of 214

    The Connecticut Light and Power Company d/b/a Eversource Energy REDACTED Docket No. 26-05-10 Date Issued September 11, 2026 EOE-259 Attachment 3 REDACTED Page 204 of 214 Attachment B There are two types of pad mounted switchgear in CT. The first is air insulated PMH Gear (Type 3, 5, 8, 9, 11, 12, and 13). The second is SF6 insulated (Vista, Trayer). In addition, there are wall mounted (Elastimold) located in customer vaults (primarily in Stamford and Hartford) that are tied into the UG system. Response Specialists would not normally respond to these outages. However, the Company may train them if they were to be utilized to restore customers while UG personnel are responding to an event. There are many more types of gear in the industry. Therefore, this is for discussion purposes only and not meant to be all-inclusive. Attachment C 198
  5. Page 205 of 214

    No text on this page. It may be a picture of a page, such as a scan or a chart.
  6. Page 206 of 214

    The Connecticut Light and Power Company d/b/a Eversource Energy REDACTED Docket No. 26-05-10 Date Issued September 11, 2026 EOE-259 Attachment 3 REDACTED Page 206 of 214 Attachment E • Matrix establishes the protocol to be followed when requesting backfilling for Response Specialist coverage. Attachment F Response Specialist Initial/Annual Training Subjects • • • • • • • • • • • • • • • • • Work site protection Auto transformer installation and removal Customer interaction ETR estimates/importance Stray voltage initial response Computer/tablet training Transformer connections, standard and unusual Ferroresonance Capacitor operations Regulator operations Direct buried & grounding DB trailer set up Von DB Primary fault finding Safe excavation practices Spitfire and Pin Pointer secondary fault finding PMH Switch gear and S&C fuse handling Recloser and loop scheme operations 200
  7. Page 207 of 214

    The Connecticut Light and Power Company d/b/a Eversource Energy REDACTED Docket No. 26-05-10 Date Issued September 11, 2026 EOE-259 Attachment 3 REDACTED Page 207 of 214 • • • Environmental training o Oil spill containment, transport and reporting o Endangered species nest removal Outage prevention – best practices (upgrading the event to prevent future outages) Standard SERT subjects will continue to be scheduled through the training department *This list of subjects may not be all inclusive and could expand as business needs demand. 201
  8. Page 208 of 214

    The Connecticut Light and Power Company d/b/a Eversource Energy REDACTED Docket No. 26-05-10 Date Issued September 11, 2026 EOE-259 Attachment 3 REDACTED Page 208 of 214 Memorandum of Understanding between Eversource Energy Connecticut and IBEW Locals 420 and 457 Reliability Shift Electrician The purpose of this document is to outline the scope and parameters of the Reliability Shift Electrician position in Connecticut as agreed to between Eversource Energy (the “Company”) and IBEW Local 420 and 457 (the “Union”), collectively referred to herein as the “Parties.” In accordance with collective bargaining agreements between the Parties dated June 1, 2022 (the “CBAs”), both Parties agree as follows. Job Duties and Description: Attachment “A” Schedule: The Company reserves the right to set the schedule. The hours of coverage will be 24 hours daily and 7 days per week. The Company is committed to have the attached schedule (Attachment C) for the RSE Organization for the term of the Contract. However, the Company and Union recognize that for this schedule to work properly, RSE employees must make a good faith effort to be available to work when needs dictate. The Company shall monitor the response for both planned overtime and call outs. If the Company determines that employees are engaging in overtime abuse, the Company may change the schedule accordingly. Prior to implementing the schedule change, the Company and Union shall meet and discuss the abuse concerns and make reasonable efforts to address these issues. Holidays: There will continue to be twelve (12) paid, eight (8) hour holidays per year. When an employee works a holiday, they will receive eight (8) hours of holiday pay at basic straight time rate and the hours worked will be paid at the applicable rates. Lieu days will continue to be administered per the contract except that in addition to eight (8) hours of holiday pay, for shifts greater than eight hours, the employee shall use vacation time, or no pay code for the remaining hours of the shift. Number of positions for staffing of the Reliability Shift Electrician organization: Staffing levels will be determined by the Company. Forcing will be limited to maintain a staff of 36 positions for the term of the contract. 202
  9. Page 209 of 214

    The Connecticut Light and Power Company d/b/a Eversource Energy REDACTED Docket No. 26-05-10 Date Issued September 11, 2026 EOE-259 Attachment 3 REDACTED Page 209 of 214 Backfilling shift vacancies within the Reliability Shift Electrician organization: The Company will determine the need to backfill open shifts and positions based on operational requirements and will be done from within the respective division. Incremental backfills; will be attempted to be filled from within the division; if unsuccessful, the Company will then utilize the entire Reliability Shift Electrician roster as appropriate. Scheduled backfills; will be posted and attempted to be filled in the respective division. All vacancies will be filled in accordance with the overtime list. The Company reserves the right to fill any portion of a shift. The Company retains the right to move resources across divisions based on operational needs regardless if the RSE are on straight time or overtime. Reporting location(s): Reliability Shift Electricians will report to a show up site, which will be the closest district or substation to home within the zone as determined by the Company or a mutually agreed upon location. The Company reserves the right to change the mutually agreed upon reporting location. The Company will determine the number of employees required to report within each zone. Coverage area: The area that is covered by The Connecticut Light and Power Company dba Eversource Energy. Supervisory Direction: Reliability Shift Electricians will be directed through Substation Operations Supervision and the Systems Operation Center (“SOC”). The Supervisor will provide the day-to-day direction for the Reliability Shift Electrician. On a limited basis, the local AWC Supervisor- Electric Field Operations will also provide direction, in coordination with Substation Operations management. Mutual Aid: Reliability Shift Electricians will not be eligible to perform mutual aid assignments off Company property. Company property is defined as any and all property owned by Eversource. Storm Assignments: Local AWC personnel, General Operating and Central Maintenance will be asked and required prior to Reliability Shift Electricians being offered to perform storm assignments on Company property outside of the Connecticut Light and Power service territory. Training: The Reliability Shift Electrician position requires a minimum qualification of Electrician. The Company will schedule all required ongoing training and updates. Ongoing training and updates will be furnished to the Business Manager when requested. 203
  10. Page 210 of 214

    The Connecticut Light and Power Company d/b/a Eversource Energy REDACTED Docket No. 26-05-10 Date Issued September 11, 2026 EOE-259 Attachment 3 REDACTED Page 210 of 214 On Call: On-Call will be paid in accordance to Article VI, Section 9 of the Teal book. Reliability Shift Electrician Staffing: Internal Candidates – Hiring process in accordance with contractual provisions. Reliability Shift Electrician positions will be posted by zone and filled by Teal Book seniority with Electricians qualified to be RSE. If one or more vacancies are not filled through the posting process, the junior qualified Electrician(s) by Teal Book seniority within the affected division will be required to accept any remaining vacancies not exceeding the initial 36 positions. The Reliability Shift Electrician(s) reclassified to their previous classification will not be required to accept upgrade to the Reliability Shift Electrician for a grace period of one (1) year. External Candidates – External candidates are defined as applicants external to the Company or not in the Substation Operations Electricians organization. Successful candidates will be offered a position within the Reliability Shift Electrician organization. Candidates who accept a position will receive training/orientation prior to beginning their new role. External hires will not be considered Company qualified during the probationary period and will be paid the “C” rate as defined in Appendix A through their probationary period in accordance with the contract. At the completion of the probationary period, candidates will receive the minimum RSE rate of pay for up to twelve months until they have demonstrated competence. The RSE rate will be applicable once the employee is fully performing the responsibilities of a Reliability Shift Electrician. Retention: During the initial posting, following the ratification of the June 2019 contract, incumbent qualified employees who elect to accept a position within the Reliability Shift Electrician organization will be retained for a period of two (2) years from date of transfer and will not be entitled to apply for posted job openings or change divisions during the retention period. The two (2) year retention will begin once initial training period is completed and the employee enters the shift rotation. The RSE rate will be applicable once the employee enters the shift rotation. All others, subsequent to the initial posting, once qualified as a Reliability Shift Electrician, will remain in the position for a minimum of two (2) years and will not be entitled to apply for posted job openings or change divisions during this retention period. Incumbent qualified employees forced into the Reliability Shift Electrician position will be retained for a minimum of 18 months. If there are more than 36 fully qualified RSE in the shift rotation, the forced employee will have the option to be released; however, the forced employee relinquishes the one year grace period and is eligible to be forced back into the RSE for the full 18 month retention period. The 18 month retention will begin once initial training period is completed and the employee enters the shift rotation. The RSE rate will be applicable on the 204

Text of EOE-260_Final.pdf

Extracted from the file · 1 page · 1,827 characters

Text of EOE-260 Attachment 1.pdf

Extracted from the file · 7 pages · 1,029 characters

Text of EOE-260 Attachment 2.pdf

Extracted from the file · 7 pages · 1,708 characters

Text of EOE-260 Attachment 3 REDACTED.pdf

Extracted from the file · 2 pages · 2,327 characters

Text of EOE-260 Attachment 4 REDACTED.pdf

Extracted from the file · 2 pages · 2,427 characters

Text of EOE-260 Attachment 6.pdf

Extracted from the file · 1 page · 466 characters

Text of EOE-260 Attachment 7.pdf

Extracted from the file · 1 page · 464 characters

Text of EOE-260 Attachment 8.pdf

Extracted from the file · 1 page · 1,331 characters

Text of EOE-260 Attachment 9.pdf

Extracted from the file · 1 page · 1,329 characters

As listed on the current system

Question(s) Answered 259, 260 (Connecticut Light and Power Company dba Eversource Energy) Date Filed: 09/29/2026

This filing on the current system (opens in a new tab)