Interrogatory responses
Answers to questions 141, 148
Files32
RRU-141_Final.pdf
PDF · 86 KB · 1 pageText searchable
Download RRU-141_Final.pdfRead the text of RRU-141_Final.pdf
RRU-148_Final.pdf
PDF · 144 KB · 2 pagesText searchable
Download RRU-148_Final.pdfRead the text of RRU-148_Final.pdf
RRU-141 Attachment 25 REDACTED FOR RELEVANCE.pdf
PDF · 2.8 MB · 9 pagesText searchable
Download RRU-141 Attachment 25 REDACTED FOR RELEVANCE.pdfRead the text of RRU-141 Attachment 25 REDACTED FOR RELEVANCE.pdf
RRU-141 Attachment 24 REDACTED FOR RELEVANCE.pdf
PDF · 2.5 MB · 7 pagesText searchable
Download RRU-141 Attachment 24 REDACTED FOR RELEVANCE.pdfRead the text of RRU-141 Attachment 24 REDACTED FOR RELEVANCE.pdf
RRU-141 Attachment 23 REDACTED FOR RELEVANCE.pdf
PDF · 2.9 MB · 10 pagesText searchable
Download RRU-141 Attachment 23 REDACTED FOR RELEVANCE.pdfRead the text of RRU-141 Attachment 23 REDACTED FOR RELEVANCE.pdf
RRU-141 Attachment 22 REDACTED FOR RELEVANCE.pdf
PDF · 3.0 MB · 11 pagesText searchable
Download RRU-141 Attachment 22 REDACTED FOR RELEVANCE.pdfRead the text of RRU-141 Attachment 22 REDACTED FOR RELEVANCE.pdf
RRU-141 Attachment 21 REDACTED FOR RELEVANCE.pdf
PDF · 2.5 MB · 8 pagesText searchable
Download RRU-141 Attachment 21 REDACTED FOR RELEVANCE.pdfRead the text of RRU-141 Attachment 21 REDACTED FOR RELEVANCE.pdf
RRU-141 Attachment 20.pdf
PDF · 3.2 MB · 23 pagesText searchable
Download RRU-141 Attachment 20.pdfRead the text of RRU-141 Attachment 20.pdf
RRU-141 Attachment 19.pdf
PDF · 3.1 MB · 20 pagesText searchable
Download RRU-141 Attachment 19.pdfRead the text of RRU-141 Attachment 19.pdf
RRU-141 Attachment 18.pdf
PDF · 2.8 MB · 20 pagesText searchable
Download RRU-141 Attachment 18.pdfRead the text of RRU-141 Attachment 18.pdf
RRU-141 Attachment 17.pdf
PDF · 3.0 MB · 20 pagesText searchable
Download RRU-141 Attachment 17.pdfRead the text of RRU-141 Attachment 17.pdf
RRU-141 Attachment 16.pdf
PDF · 3.0 MB · 20 pagesText searchable
Download RRU-141 Attachment 16.pdfRead the text of RRU-141 Attachment 16.pdf
RRU-141 Attachment 15.pdf
PDF · 2.6 MB · 18 pagesText searchable
Download RRU-141 Attachment 15.pdfRead the text of RRU-141 Attachment 15.pdf
RRU-141 Attachment 14.pdf
PDF · 2.7 MB · 20 pagesText searchable
Download RRU-141 Attachment 14.pdfRead the text of RRU-141 Attachment 14.pdf
RRU-141 Attachment 13.pdf
PDF · 1.8 MB · 15 pagesText searchable
Download RRU-141 Attachment 13.pdfRead the text of RRU-141 Attachment 13.pdf
RRU-141 Attachment 12.pdf
PDF · 2.7 MB · 19 pagesText searchable
Download RRU-141 Attachment 12.pdfRead the text of RRU-141 Attachment 12.pdf
RRU-141 Attachment 11.pdf
PDF · 2.7 MB · 19 pagesText searchable
Download RRU-141 Attachment 11.pdfRead the text of RRU-141 Attachment 11.pdf
RRU-141 Attachment 10.pdf
PDF · 2.8 MB · 19 pagesText searchable
Download RRU-141 Attachment 10.pdfRead the text of RRU-141 Attachment 10.pdf
RRU-141 Attachment 09.pdf
PDF · 2.8 MB · 19 pagesText searchable
Download RRU-141 Attachment 09.pdfRead the text of RRU-141 Attachment 09.pdf
RRU-141 Attachment 08.pdf
PDF · 2.7 MB · 19 pagesText searchable
Download RRU-141 Attachment 08.pdfRead the text of RRU-141 Attachment 08.pdf
RRU-141 Attachment 07.pdf
PDF · 2.7 MB · 19 pagesText searchable
Download RRU-141 Attachment 07.pdfRead the text of RRU-141 Attachment 07.pdf
RRU-141 Attachment 06.pdf
PDF · 2.6 MB · 19 pagesText searchable
Download RRU-141 Attachment 06.pdfRead the text of RRU-141 Attachment 06.pdf
RRU-141 Attachment 05.pdf
PDF · 2.6 MB · 19 pagesText searchable
Download RRU-141 Attachment 05.pdfRead the text of RRU-141 Attachment 05.pdf
RRU-141 Attachment 04.pdf
PDF · 2.7 MB · 19 pagesText searchable
Download RRU-141 Attachment 04.pdfRead the text of RRU-141 Attachment 04.pdf
RRU-141 Attachment 03.pdf
PDF · 2.8 MB · 17 pagesText searchable
Download RRU-141 Attachment 03.pdfRead the text of RRU-141 Attachment 03.pdf
RRU-141 Attachment 02.pdf
PDF · 2.1 MB · 19 pagesText searchable
Download RRU-141 Attachment 02.pdfRead the text of RRU-141 Attachment 02.pdf
RRU-141 Attachment 01.pdf
PDF · 1.7 MB · 14 pagesText searchable
Download RRU-141 Attachment 01.pdfRead the text of RRU-141 Attachment 01.pdf
RRU-148 Attachment 5 REDACTED.pdf
PDF · 3.0 MB · 18 pagesText read by machine from a scan; may contain errors, especially in numbers
Download RRU-148 Attachment 5 REDACTED.pdfScanned pages and text of RRU-148 Attachment 5 REDACTED.pdf
RRU-148 Attachment 4 REDACTED.pdf
PDF · 4.3 MB · 20 pagesText searchable
Download RRU-148 Attachment 4 REDACTED.pdfRead the text of RRU-148 Attachment 4 REDACTED.pdf
RRU-148 Attachment 3 REDACTED.pdf
PDF · 8.2 MB · 29 pagesText searchable
Download RRU-148 Attachment 3 REDACTED.pdfRead the text of RRU-148 Attachment 3 REDACTED.pdf
RRU-148 Attachment 2 REDACTED.pdf
PDF · 12 MB · 28 pagesText searchable
Download RRU-148 Attachment 2 REDACTED.pdfRead the text of RRU-148 Attachment 2 REDACTED.pdf
RRU-148 Attachment 1 REDACTED.pdf
PDF · 8.3 MB · 28 pagesText searchable
Download RRU-148 Attachment 1 REDACTED.pdfRead the text of RRU-148 Attachment 1 REDACTED.pdf
Text of RRU-141 Attachment 24 REDACTED FOR RELEVANCE.pdf
Extracted from the file · 7 pages, 1 without text · 1,152 characters
Text of RRU-141 Attachment 23 REDACTED FOR RELEVANCE.pdf
Extracted from the file · 10 pages, 2 without text · 1,545 characters
Text of RRU-141 Attachment 22 REDACTED FOR RELEVANCE.pdf
Extracted from the file · 11 pages, 2 without text · 1,739 characters
Text of RRU-141 Attachment 21 REDACTED FOR RELEVANCE.pdf
Extracted from the file · 8 pages, 1 without text · 1,344 characters
Text of RRU-141 Attachment 20.pdf
Extracted from the file · 23 pages · 3,536 characters
Text of RRU-141 Attachment 19.pdf
Extracted from the file · 20 pages · 3,090 characters
Text of RRU-141 Attachment 18.pdf
Extracted from the file · 20 pages · 3,090 characters
Text of RRU-141 Attachment 17.pdf
Extracted from the file · 20 pages · 3,089 characters
Text of RRU-141 Attachment 16.pdf
Extracted from the file · 20 pages · 3,091 characters
Text of RRU-141 Attachment 15.pdf
Extracted from the file · 18 pages · 2,795 characters
Text of RRU-141 Attachment 14.pdf
Extracted from the file · 20 pages · 3,094 characters
Text of RRU-141 Attachment 13.pdf
Extracted from the file · 15 pages · 2,353 characters
Text of RRU-141 Attachment 12.pdf
Extracted from the file · 19 pages · 2,946 characters
Text of RRU-141 Attachment 11.pdf
Extracted from the file · 19 pages · 2,946 characters
Text of RRU-141 Attachment 10.pdf
Extracted from the file · 19 pages · 2,945 characters
Text of RRU-141 Attachment 09.pdf
Extracted from the file · 19 pages · 2,928 characters
Text of RRU-141 Attachment 08.pdf
Extracted from the file · 19 pages · 3,543 characters
Text of RRU-141 Attachment 07.pdf
Extracted from the file · 19 pages · 3,541 characters
Text of RRU-141 Attachment 06.pdf
Extracted from the file · 19 pages · 3,541 characters
Text of RRU-141 Attachment 05.pdf
Extracted from the file · 19 pages · 2,922 characters
Text of RRU-141 Attachment 04.pdf
Extracted from the file · 19 pages · 2,924 characters
Text of RRU-141 Attachment 03.pdf
Extracted from the file · 17 pages · 3,179 characters
Text of RRU-141 Attachment 02.pdf
Extracted from the file · 19 pages · 3,583 characters
Text of RRU-141 Attachment 01.pdf
Extracted from the file · 14 pages · 2,847 characters
Scanned pages and machine-read text of RRU-148 Attachment 5 REDACTED.pdf

The scanned page Machine-read text
The Connecticut Light and Power Company d/b/a Eversource Energy REDACTED Docket No. 26-05-10 Date Issued October 23, 2026 RRU-148 Attachment 5 REDACTED Page 8 of 18 - 8 - SECTION 9. TERMINATION (a) Upon termination of the Memorandum of the retirement of one or more of the Joint-Use Facilities or upon a significant decrease in the use of the facilities specified in one or more of the attachments to Appendix I attached hereto, the Companies shall determine by mutual agreement such appropriate adjustments and provisions as may be necessary to provide for reasonable reimbursement to each owning Company for and with respect to such portions of the facilities constructed to effectuate the purposes of this Memorandum but which are not required by the owning Company in connection with its own operations after such termination or decrease. (b) Notwithstanding the termination of this Memorandum or the retirement of one or more of the facilities listed in the attachments to Appendix I attached hereto, the applicable provisions shall continue in effect after such termination to the extent necessary to provide for adjustments and provisions under this Section and for final billing and other adjustments. SECTION 10. ARBITRATION In the event of any dispute between any of the Companies or failure of any of the Companies to agree as to any matter to be determined by mutual agreement under the provisions of this Memorandum or as to the interpretation of or operation under any provision of this Memorandum upon notice from any Company, such dispute shall be submitted to arbitration. If agreement is not reached regarding appointment of an arbitrator within 30 days after the notice of submission to arbitration is given by a Company, any affected Company may apply to the American Arbitration Association for appointment of the arbitrator. The arbitrator shall be a disinterested person who is qualified in the area of the matter in dispute. The arbitrator shall conduct the proceeding in accordance with and subject to the rules of the American
The scanned page Machine-read text
The Connecticut Light and Power Company d/b/a Eversource Energy REDACTED Docket No. 26-05-10 Date Issued October 23, 2026 RRU-148 Attachment 5 REDACTED Page 9 of 18 - 9 - Arbitration Association and shall render his decision with respect to the matter in controversy as promptly as practicable. The arbitrator shall be authorized only to interpret and apply the provisions of this Memorandum, and shall have no power to modify or change this Memorandum in any manner. The decision of the arbitrator shall be final and binding on the Companies. Each of the Companies in any arbitration proceeding shall bear its own expenses, and the expenses and fees of the arbitrator and any other expenses arising from the arbitration proceeding shall be shared equally by the Companies participating in the arbitration. SECTION 11. MISCELLANEOUS (a) This Memorandum shall be binding upon and shall inure to the benefit of the Companies and their respective successors and assigns. (b) This Memorandum including all Appendices, Exhibits and Attachments is subject to present and future state or federal statutes and to present or future regulations or orders properly issued by any regulatory agencies having jurisdiction over matters contained herein. SECTION 12. APPLICABLE LAW This Memorandum shall be interpreted, performed and controlled by and in accordance with the laws of the State of Connecticut.
The scanned page Machine-read text
The Connecticut Light and Power Company d/b/a Eversource Energy REDACTED Docket No. 26-05-10 Date Issued October 23, 2026 RRU-148 Attachment 5 REDACTED Page 10 of 18 - 10 - THE CONNECTICUT LIGHT AND POWER COMPANY By [redacted] 7/2/93 Its Vice President-Marketing [redacted] WESTERN MASSACHUSETTS ELECTRIC COMPANY By [redacted] 7/2/93 Its Vice President-Marketing [redacted] HOLYOKE WATER POWER COMPANY By [redacted] 7/2/93 Its Vice President-Marketing [redacted] HOLYOKE POWER AND ELECTRIC COMPANY By [redacted] 7/2/93 Its Vice President-Marketing [redacted]
The scanned page Machine-read text
The Connecticut Light and Power Company d/b/a Eversource Energy REDACTED Docket No. 26-05-10 Date Issued October 23, 2026 RRU-148 Attachment 5 REDACTED Page 11 of 18 - 11 - EXHIBIT A The following agreement is to be terminated as of the effective date of this Agreement and relating to the specific facility: 1. Agreement between The Hartford Electric Light Company and Western Massachusetts Electric Company relating to the Southwick Substation (MWME FPC Rate Schedule 13).
The scanned page Machine-read text
The Connecticut Light and Power Company d/b/a Eversource Energy REDACTED Docket No. 26-05-10 Date Issued October 23, 2026 RRU-148 Attachment 5 REDACTED Page 12 of 18 Appendix I Local Facilities Agreement The annual costs of the Local Facilities shall be the estimated annual costs of owning, operating, maintaining, and supporting those facilities, including applicable leasing costs. These costs shall be computed annually. In determining such costs, the provisions of the Uniform System of Accounts prescribed by the Federal Energy Regulatory Commission for major electric utilities and licensees shall be controlling, to the extent applicable. I. Determination of Investment Base The Investment Base is the sum of Net Investment and Working Capital as determined at the end of the preceding calendar year unless there is a substantial change (of $500,000 or more) in the Investment Base during the calendar year. A. Net Investment Net investment shall be the original cost (including the cost of any betterments, improvements, and additions thereto and excluding the cost of any retirements therefrom) of the Local Facility, as recorded on the owner's books in the applicable FERC Accounts 360-362, 364-368, 391, 394 and 397, less the sum of (1) accumulated depreciation and (2) accumulated deferred federal and state income taxes arising from liberalized depreciation and accelerated amortization. Accumulated depreciation shall reflect retirements and net salvage realized. Accumulated deferred income taxes shall be computed using the same life, methods, rates, salvage factors, and accounting practices as reflected on the Owner's books of account, and shall be applicable to investments made in such facilities on or subsequent to the effective date of this Agreement. In the event that the Owner has employed a liberalized tax depreciation or accelerated depreciation method and thereafter employs a different method, any necessary allowance or adjustment shall be made in order to insure that any such change of methods does not result in any overcollection or undercollection by the Owner. B. Working Capital Working capital to be included in the Investment Base shall include 45 days (out of 360) of related operation and maintenance expense and the Owner's best estimate of the cost of related materials and supplies and an appropriate allowance for any payments made pursuant to the prepayment provisions of applicable leases. II. Determination of Annual Carrying Costs of Local Facilities The following costs factors shall be used in determining the annual carrying costs of the Local Facilities:
The scanned page Machine-read text
The Connecticut Light and Power Company d/b/a Eversource Energy REDACTED Docket No. 26-05-10 Date Issued October 23, 2026 RRU-148 Attachment 5 REDACTED Page 13 of 18 - 2 - A. Operation and Maintenance Expense B. Property Tax Expense C. Depreciation Expense D. Investment Return E. Income Tax Expense F. Investment Tax Credit Allowance G. Leasing Expense H. Other Tax Expense A. Operation and Maintenance Expense Operation and maintenance expense means an amount equal to the sum of the following: (1) the actual cost (or the best estimate thereof) of the annual expense of operating and maintaining the Local Facility developed in accordance with the formulas listed in Exhibit 2 to this Appendix I; (2) an appropriate allowance to cover the related administrative and general expenses, including, but not limited to, employee pensions and benefits, federal and state taxes related to the direct payroll expense, and property insurance expense for the Local Facility. The allowance for the administrative and general expenses is initially estimated at 40 percent of the operation and maintenance expense provided in (1) above. This allowance shall be subject to the final decision in FERC Docket Nos. ER90-390-000 et al., and shall be revised in accordance with the results of such final decision. B. Property Tax Expense Property tax expense shall consist of those taxes or excise payments that are based upon the assessed value of the Local Facility, times the taxing authorities appropriate tax rate and specifically identified with that facility, or the Owner's best estimate thereof. The procedures for determining the amounts of any such estimates shall be determined by the Owner. The Owner shall have the sole discretion in any negotiations with taxing authorities. C. Depreciation Expense Depreciation expense shall be determined on a straight line method, vintage/broad group procedure and remaining life technique as reflected on the Owner's book of account. D. Investment Return Investment return for the Local Facility shall be determined by multiplying the Owner's Investment Base by the Owner's composite cost of capital. The Owner's composite cost of capital shall be computed on the basis of its cost, expressed in percentages, for (1) bonds and other long-term indebtedness, (2) preferred stock, and (3) for the return on common equity which will be fixed at 12.93%. These costs shall be combined in accordance with the following formula to determine the Owner's composite cost of capital:
The scanned page Machine-read text
The Connecticut Light and Power Company REDACTED d/b/a Eversource Energy Docket No. 26-05-10 Date Issued October 23, 2026 RRU-148 Attachment 5 REDACTED Page 14 of 18 - 3 - Composite Cost of Capital = AxB + CxD + ExF in which: A = the Owner's cost for long-term indebtedness B = the percentage of the Owner's capitalization represented by long-term indebtedness C = the Owner's cost for preferred stock D = the percentage of the Owner's capitalization represented by preferred stock E = the Owner's return on common equity F = the percentage of the Owner's capitalization represented by common equity In the above formula, the Owner's capitalization consists of its components of long-term indebtedness, preferred stock, and common equity. Those components and the percentage of capitalization represented by each of those components shall be rounded off to the nearest whole number. The Owner's investment return for a year shall be computed initially at the beginning of the year on the basis of its investment base and its composite cost of capital as of the beginning of the year. The investment return, as so computed, shall be recomputed each time that a substantial change in its Investment Base or composite cost of capital occurs during the year, and at any such other time as the Companies mutually agree is appropriate. E. Income Tax Expense An allowance for income taxes shall be computed in accordance with the following formula: T_e / (1-T_e) x [(IB (PE + CE)) + (D_B - D_T)] T_e = the effective combined federal and state statutory income tax rate of the Owner IB = Investment Base PE = Weighted Preferred Stock Component (C x D in II.D.) CE = Weighted Common Equity Component (E x F in II.D.) D_B = Book depreciation D_T = Tax depreciation Where the book depreciation (D_B) and tax depreciation (D_T) apply only to investments made in the Local Facility prior to the effective date of this Agreement.
The scanned page Machine-read text
The Connecticut Light and Power Company d/b/a Eversource Energy REDACTED Docket No. 26-05-10 Date Issued October 23, 2026 RRU-148 Attachment 5 REDACTED Page 15 of 18 - 4 - F. Investment Tax Credit Allowance Applicable investment tax credits are those based upon the Owner's applicable investments placed in service on or subsequent to the effective date of this Agreement. An allowance for any applicable investment tax credit shall be reflected ratably over the remaining book depreciable life of the Local Facility. This allowance for the normalized investment tax credit shall be calculated by dividing the investment tax credit by the estimated remaining book depreciable life, by one minus the effective tax rate, as described below: IC / (1-T_e)N IC = the applicable investment tax credit T_e = as previously defined N^e = remaining book depreciable life of the Local Facility expressed in years G. Leasing Expense Leasing expense shall consist of those leasing costs (or rental payments) charged to the Owner and related to the Local Facility. H. Other Tax Expense Other tax expense shall consist of any taxes or excises which are incurred in the future as a result of constructing, owning, operating, or leasing the Local Facility. Such tax expense shall include any tax, on gross revenues or any tax pertaining to the billing of those annual costs, which is not recognized elsewhere in this Agreement. III. Allocation of Annual Carrying Costs of NU Local Facilities The Annual Carrying Costs listed above (II.A. through II.H.) shall be allocated to the Participants as follows: A. Transmission Facilities Jointly used transmission facilities shall be allocated on the basis of the 16 month ratchet billing peak loads. B. Substation Facilities One-half of the cost of such jointly used substation facilities shall be allocated on the basis of the 16 month ratchet billing peak loads, and the remainder of such costs shall be allocated on the basis of the number of feeder positions assigned. Spare (unloaded) feeder positions shall be included in this allocation. When one party's feeder is tapped in the field, this allocation will still reflect the number of feeder positions assigned to each party.
The scanned page Machine-read text
The Connecticut Light and Power Company d/b/a Eversource Energy REDACTED Docket No. 26-05-10 Date Issued October 23, 2026 RRU-148 Attachment 5 REDACTED Page 16 of 18 - 5 - C. Distribution Facilities 1. Duct Lines - Shall be allocated on the basis of the number of ducts actually utilized by each party. Spare ducts shall be included in this allocation. 2. Feeders - When one party's feeder is tapped in the field, the costs of the jointly used portion shall be allocated on an equal basis between the parties.
The scanned page Machine-read text
The Connecticut Light and Power Company d/b/a Eversource Energy REDACTED Docket No. 26-05-10 Date Issued October 23, 2026 RRU-148 Attachment 5 REDACTED Page 17 of 18 Exhibit 2 to Appendix I Page 1 of 2 SUBSTATIONS FORMULAS FOR DETERMINING OPERATION EXPENSES
FORMULAS FOR DETERMINING MAINTENANCE EXPENSESAccount Formula 582 Unit Station Equipment (ACCT 362) / Total Station Equipment (ACCT 362) x Dist. Substation Exp. (ACCT 582) 588 Unit Station Equip. & Structures & Imp. (ACCTS 362 & 361) / Total Distribution Investment (ACCTS 361 - 373) x Misc. Distr. Exp. (ACCT 588) 580 Allocated 582 & 588 / Total Distribution Expenses (581 - 589) x Supervision & Eng. (ACCT 580) Account Formula 591 Unit Structures & Imps. (ACCT 361) / Total Acct. Struct. & Imp. (ACCT 361) x Distr. Substation Maint. Exp. (ACCT 591) 592 Unit Station Equip. (ACCT 362) / Total Acct. Station Equip (ACCT 362) x Distr. Substation Maint. Exp. (ACCT 592) 598 Unit Station Equip & Structures & Imps. (ACCT 361 & 362) / Total Distribution Investment (ACCTS 361 - 373) x Misc. Maintenance Expense (ACCT 598) 590 Allocated 591 + 592 + 598 / Total Maintenance Expenses (ACCTS 591 - 598) x Supervision & Eng (ACCT 590)
Text of RRU-148 Attachment 4 REDACTED.pdf
Extracted from the file · 20 pages, 18 without text · 328 characters
Text of RRU-148 Attachment 3 REDACTED.pdf
Extracted from the file · 29 pages, 27 without text · 3,210 characters
Text of RRU-148 Attachment 2 REDACTED.pdf
Extracted from the file · 28 pages, 6 without text · 6,292 characters
Text of RRU-148 Attachment 1 REDACTED.pdf
Extracted from the file · 28 pages, 27 without text · 2,852 characters
As listed on the current system