Skip to main content

A prototype public docket site for the Connecticut Public Utilities Regulatory Authority

Utility Dockets and Filings

Interrogatory responses

Answers to questions 159

ResponseFiled by Connecticut Light and Power Company dba Eversource Energy51 files
Part of docket 26-05-10Open
  • Electric
Application of The Connecticut Light and Power Company d/b/a Eversource Energy to Amend its Rate Schedules

Files51

Search terms highlighted
Eversource rate increase is on 36 pages across 17 files of the text below, highlighted. Go to the first matchClear highlighting
Words on different pages
Words on different pages
Words on different pages

Text of RRU-159 Attachment 23.xlsx

Sheet names, column headings and text cells; numbers left out · first 300,000 characters

Text of RRU-159 Attachment 23.pdf

Extracted from the file · 1,160 pages · 16,330,154 characters

Text of RRU-159 Attachment 22.xlsx

Sheet names, column headings and text cells; numbers left out · first 300,000 characters

Text of RRU-159 Attachment 22.pdf

Extracted from the file · 1,203 pages · 14,349,246 characters

Text of RRU-159 Attachment 21.xlsx

Sheet names, column headings and text cells; numbers left out · first 300,000 characters

Text of RRU-159 Attachment 21.pdf

Extracted from the file · 1,203 pages · 13,880,364 characters

Text of RRU-159 Attachment 20.xlsx

Sheet names, column headings and text cells; numbers left out

Text of RRU-159 Attachment 20.pdf

Extracted from the file · 16 pages · 151,762 characters

Text of RRU-159 Attachment 19.xlsx

Sheet names, column headings and text cells; numbers left out

Text of RRU-159 Attachment 19.pdf

Extracted from the file · 1 page · 5,328 characters

Text of RRU-159 Attachment 18.xlsx

Sheet names, column headings and text cells; numbers left out · first 300,000 characters

Text of RRU-159 Attachment 18.pdf

Extracted from the file · 640 pages · 7,983,236 characters

Text of RRU-159 Attachment 17.xlsx

Sheet names, column headings and text cells; numbers left out · first 300,000 characters

Text of RRU-159 Attachment 17.pdf

Extracted from the file · 855 pages · 14,651,941 characters

Text of RRU-159 Attachment 16.xlsx

Sheet names, column headings and text cells; numbers left out · first 300,000 characters

Text of RRU-159 Attachment 16.pdf

Extracted from the file · 489 pages · 7,076,557 characters

Text of RRU-159 Attachment 15.xlsx

Sheet names, column headings and text cells; numbers left out · first 300,000 characters

Text of RRU-159 Attachment 15.pdf

Extracted from the file · 897 pages · 15,723,777 characters

Text of RRU-159 Attachment 14 .pdf

Extracted from the file · 1 page · 2,589 characters

Text of RRU-159 Attachment 14.xlsx

Sheet names, column headings and text cells; numbers left out

Text of RRU-159 Attachment 13.xlsx

Sheet names, column headings and text cells; numbers left out

Text of RRU-159 Attachment 13.pdf

Extracted from the file · 1 page · 427 characters

Text of RRU-159 Attachment 12.xlsx

Sheet names, column headings and text cells; numbers left out · first 300,000 characters

Text of RRU-159 Attachment 12.pdf

Extracted from the file · 802 pages · 14,341,138 characters

Text of RRU-159 Attachment 11.xlsx

Sheet names, column headings and text cells; numbers left out · first 300,000 characters

Text of RRU-159 Attachment 11.pdf

Extracted from the file · 858 pages · 15,906,152 characters

Text of RRU-159 Attachment 10.xlsx

Sheet names, column headings and text cells; numbers left out

Text of RRU-159 Attachment 10.pdf

Extracted from the file · 1 page · 822 characters

Text of RRU-159 Attachment 09.xlsx

Sheet names, column headings and text cells; numbers left out · first 300,000 characters

Text of RRU-159 Attachment 09.pdf

Extracted from the file · 449 pages · 7,355,312 characters

Text of RRU-159 Attachment 08.xlsx

Sheet names, column headings and text cells; numbers left out · first 300,000 characters

Text of RRU-159 Attachment 08.pdf

Extracted from the file · 867 pages · 13,878,236 characters

Text of RRU-159 Attachment 07.xlsx

Sheet names, column headings and text cells; numbers left out · first 300,000 characters

Text of RRU-159 Attachment 07.pdf

Extracted from the file · 869 pages · 15,728,932 characters

Text of RRU-159 Attachment 06.xlsx

Sheet names, column headings and text cells; numbers left out · first 300,000 characters

Text of RRU-159 Attachment 06.pdf

Extracted from the file · 459 pages · 8,128,897 characters

Text of RRU-159 Attachment 05.xlsx

Sheet names, column headings and text cells; numbers left out · first 300,000 characters

Text of RRU-159 Attachment 05.pdf

Extracted from the file · 879 pages · 16,073,548 characters

Text of RRU-159 Attachment 04.xlsx

Sheet names, column headings and text cells; numbers left out

Text of RRU-159 Attachment 04.pdf

Extracted from the file · 5 pages · 20,994 characters

Words on different pages

This spreadsheet is large. Its searchable text keeps the sheet names, column headings and text cells and stops at 300,000 characters, so search may miss words further in. Download the file for every cell and figure.

  1. Part 22 of 77

    CS00009L | PEPPERIDGE 28A-PURCH S/S REMOTE RAC | PURCHASE 29 CBS ARCSAFE REMOTE RACKING UNITS FOR SUBSTATIONS THAT CURRENTLY DO NOT HAVE A SYSTEM THAT WORKS SAFELY __________________________________________CMK | Benefits-B01 CS00009M | N SQUARE 25G - PURCH S/S REMOTE RAC | PURCHASE 29 CBS ARCSAFE REMOTE RACKING UNITS FOR SUBSTATIONS THAT CURRENTLY DO NOT HAVE A SYSTEM THAT WORKS SAFELY __________________________________________CMK | Benefits-B01 CS00009N | SHEPAUG 13A - PURCH S/S REMOTE RACK | PURCHASE 29 CBS ARCSAFE REMOTE RACKING UNITS FOR SUBSTATIONS THAT CURRENTLY DO NOT HAVE A SYSTEM THAT WORKS SAFELY __________________________________________CMK | Benefits-B01 CS000211 | Manchester 3A SS Lighting Upgrades | Install and/or upgrade s/s lighting fixtures and additional 120VAC outlets at various CL&P Substations. Fixtures will be ordered & stocked at BCS and s/b charges to the appropriate wo # when picked up from the warehouse | Benefits-B01 CS000214 | E Meriden 21P S/S Lighting Upgrades | Install and/or upgrade S/S lighting fixtures and additional 120VAC outlets at various CL&P Substations. All fixtures will be ordered & stocked at BCS and s/b charged to the appropriate WO # when they are picked up at the warehouse. | Benefits-B01 CS000215 | Chippen Hill 15U S/S Lighting Upgds | Install and/or upgrade S/S lighting fixtures and additional 120VAC outlets at various CL&P Substations. All fixtures will be ordered & stocked at BCS and s/b charged to the appropriate WO # when they are picked up at the warehouse. | Benefits-B01 CS000216 | Green Hill 30R S/S Lighting Upgrds | Install and/or upgrade S/S lighting fixtures and additional 120VAC outlets at various CL&P Substations. All fixtures will be ordered & stocked at BCS and s/b charged to the appropriate WO # when they are picked up at the warehouse. | Benefits-B01 CS000218 | NW Hartford 2N S/S Lighting Upgrds | Install and/or upgrade S/S lighting fixtures and additional 120VAC outlets at various CL&P Substations. All fixtures will be ordered & stocked at BCS and s/b charged to the appropriate WO # when they are picked up at the warehouse. | Benefits-B01 CS000219 | Bristol 11K S/S Lighting Upgrades | Install and/or upgrade S/S lighting fixtures and additional 120VAC outlets at various CL&P Substations. All fixtures will be ordered & stocked at BCS and s/b charged to the appropriate WO # when they are picked up at the warehouse. | Benefits-B01 CS00021A | Canton 5R S/S Lighting Upgrades | Install and/or upgrade S/S lighting fixtures and additional 120VAC outlets at various CL&P Substations. All fixtures will be ordered & stocked at BCS and s/b charged to the appropriate WO # when they are picked up at the warehouse. | Benefits-B01 CS00021B | Rocky Hill 3R S/S Lighting Upgrades | Install and/or upgrade S/S lighting fixtures and additional 120VAC outlets at various CL&P Substations. All fixtures will be ordered & stocked at BCS and s/b charged to the appropriate WO # when they are picked up at the warehouse. | Benefits-B01 CS00021C | Southington 4C S/S Lighting Upgrds | Install and/or upgrade S/S lighting fixtures and additional 120VAC outlets at various CL&P Substations. All fixtures will be ordered & stocked at BCS and s/b charged to the appropriate WO # when they are picked up at the warehouse. | Benefits-B01 CS00021D | S Meadow 1A S/S Lighting Upgrades | Install and/or upgrade S/S lighting fixtures and additional 120VAC outlets at various CL&P Substations. All fixtures will be ordered & stocked at BCS and s/b charged to the appropriate WO # when they are picked up at the warehouse. | Benefits-B01 CS00021E | SW Hartford 47N S/S Lighting Upgrds | Install and/or upgrade S/S lighting fixtures and additional 120VAC outlets at various CL&P Substations. All fixtures will be ordered & stocked at BCS and s/b charged to the appropriate WO # when they are picked up at the warehouse. | Benefits-B01
  2. Part 23 of 77

    CS00021F | E Hartford S/S Lighting Upgrades | Install and/or upgrade S/S lighting fixtures and additional 120VAC outlets at various CL&P Substations. All fixtures will be ordered & stocked at BCS and s/b charged to the appropriate WO # when they are picked up at the warehouse. | Benefits-B01 CS00021G | Riverside 2R S/S Lighting Upgrades | Install and/or upgrade S/S lighting fixtures and additional 120VAC outlets at various CL&P Substations. All fixtures will be ordered & stocked at BCS and s/b charged to the appropriate WO # when they are picked up at the warehouse. | Benefits-B01 CS00021H | Bloomfield 3B S/S Lighting Upgrades | Install and/or upgrade S/S lighting fixtures and additional 120VAC outlets at various CL&P Substations. All fixtures will be ordered & stocked at BCS and s/b charged to the appropriate WO # when they are picked up at the warehouse. | Benefits-B01 CS00021K | Williams St 9L S/S Lighting Upgrds | Install and/or upgrade S/S lighting fixtures and additional 120VAC outlets at various CL&P Substations. All fixtures will be ordered & stocked at BCS and s/b charged to the appropriate WO # when they are picked up at the warehouse. | Benefits-B01 CS000581 | Install Feeder Position (Fusion Sol | Tunnel 12S - Install a new 23kV feeder (12S6) which will serve as an express feed to the new Fusion 20 MW Photovoltaic Distributed Generation. The new feeder will require the addition of one 23kV Tie breaker, three group-operated disconnect switches, PTs and one feeder recloser. | Benefits-B01 CS000691 | Maple 24-Remove Substation | Maple 24 - Remvoe all equipment, foundations, fence and trap rocks. All equipment will be scrapped except for the transformers (24-1X and 24-2X). Both transformers will be evaluated for possible use as system spare, otherwise they should both be scrapped. The substation site should be cleared and turned over to Real Estate for sale. | Benefits-B01 CS000841 | Replace 3X Transformer | Manchester 3A - Replace the 3A-3X transformer. The existing 115kV Wye to 22kV Delta 45 MVA transformer will be replaced with a new 115kV Delta to 23kV Wye 60 MVA transformer. The existing 3A-3X power transformer as well as the associated 3A-3Y grounding transformer will be removed and scrapped. | Benefits-B01 CS001081 | Moosup 19Y-Remove Substation | Moosup 19Y - Remove the substation. All of the equipment will need to be removed, including the foundations and the 19Y-1X transformer will be scrapped. The fence wnd trap rock will remain and the site will be kept because a pole line crosses the small site. | Benefits-B01 CS001421 | Battery Upgrades | South Windsor 14L - UPgrade the existing battery set to include capacity for the additional Cip v5 equipment. | Benefits-B01 CS001524 | Recloser Automation | East Bantam 19U - Install new station FORM 6 Reclosers on Eversource CT feeders to address Recloser Automation. This project also includes installation of a DSCADA communications system that will allow the SOC to remotely apply the control fast-trip feature prior to commencing any live-line feeder work. The overall project includes complete installation of all necessary protection settings, control and communications devices. | Benefits-B01 CS001526 | Recloser Automation | Cornwall 37J - Install new station FORM 6 Reclosers on Eversource CT feeders to address Recloser Automation. This project also includes installation of a DSCADA communications system that will allow the SOC to remotely apply the control fast-trip feature prior to commencing any live-line feeder work. The overall project includes complete installation of all necessary protection settings, control and communications devices. | Benefits-B01 CS001661 | Mansfield 12J Install 12J-4X transf | Furnish necessary engineering and design to create a 23kV source at Mansfield 12J substation to replace the existing 27.6kV transformer and associated feeders. Work includes the following installation:_x000D__x000D_
  3. Part 24 of 77

    • One 69-115/23kV 62.5MVA (12J-4X) transformer_x000D__x000D_ • One new lineup of 23kV Double Bus Metaclad Switchgear_x000D__x000D_ • Three 115kV circuit switchers_x000D__x000D_ • One 115kV Motor Operated Disconnect Switch_x000D__x000D_ • Replacement of existing electromechanical relays for the 12J-1X, 12J-2X transformers with new microprocessor based SEL relays_x000D__x000D_ • Installation of l 12J-3S, 12J-4S, 12J-3H, 12J-4H transformers_x000D__x000D_ • Installation of six 115kV cable potheads [(2) cable pothead structures] and arresters_x000D__x000D_ • Approximately 1500 ft. total 115kV XLPE cable 500 ft. per phase _x000D__x000D_ • Install new ground grid to cover the expended fenced area_x000D__x000D_ • 25kV power cables between switchgear and riser poles (located outside of the substation fence)t_x000D__x000D_ • Required conduits and foundations for new equipment_x000D__x000D_ _x000D__x000D_ | Benefits-B01 CS001751 | Install New Feeder (DG) | Tracy 14M - Establish a new feeder position 14M13 for a DG project associated with the RES Americas' 20MW PV DG project. The new 14M13 overhead feeder position will be between 14M-14T-6 and 14M-15T-6 bus switches. A new vacuum 23kV circuit breaker 14M13-2 will be installed using steel spans on the existing foundation, a new group operated disconnec tswitch14M13-5, a new set of PTs and arresters will also be installed. | Benefits-B01 CS001951 | South MeaSpare Transformer Assembly | Spare Transformer Assembly - Purchase, assemble, fill and test a system spare transformer for storage at the South Meadow Storage Facility in Hartford, CT. The new system spare will be 60 MVA, 115-23kV, 14.2% impedance. Catalog ID 465287. This new spare will take the place of the existing spare (Catalog 443766) which will be moved from the SOuth Meadow Storage Facility to Tracy 14M substation in September. | Benefits-B01 CS002816 | DC Battery Voltage Monitoring | Bloomfield 3B - Implement station DC Battery Voltage Monitoring as a backup system to the AT10 charger internal alarm system. | Benefits-B01 CS005951 | PI Vision Transformer Monitor Repl | This project will replace transformer monitoring displays used by the substation technical engineering group to monitor asset health real-time by visualizing data collected using online equipment monitors. An external vendor will be funded to create these displays in PI Vision, an existing visualization tool on the Eversource network. A new PI Asset Framework database will be developed. The structure of the dashboard includes an Overview page and nine sub-pages. The objective of the Overview page is to provide users a quick look at the health of each transformer and to highlight via color coding the potential issues to be investigated further. | Benefits-B01 CSBD11C1 | CTE Supplier Billing DCKT | CTE Supplier Billing DCKT | Benefits-B01 CSKD0011 | Common Stock Dividend | Common Stock DividendNT011 | Benefits-B01 CSTC0011 | Customer Care | Customer Care EPO Credit | Benefits-B01 CSTR0011 | Clean / stock truck | Clean / stock truck | Benefits-B01 CT13D001 | NEW MILFORD OC-3 MICROWAVE EXPANSIO | ADD AN ADDITIONA OC-3 MICROWAVE HOP BETWEEN SOUTH MOUNTAIN TO NEW MILFORD AND NEW MILFORD TO NEWTOWN. REQUESTER: M. CARBARY______MGR. G. BLANCHARD | Benefits-B01 CT13D002 | SOUTH MOUNTAIN OC-3 MICROWAVE EXPAN | ADD AN ADDITIONA OC-3 MICROWAVE HOP BETWEEN TALCOTT MOUNTAIN TO SOUTH MOUNTAI TO NEW MILFORD RADIO SITES. REQUESTER: M. CARBARY______MGR. G. BLANCHARD | Benefits-B01 CT13D003 | BERLIN MULTIPLEXER FOR OC-2 MICRO. | ADDTION DMXTEND MULTIPLEXER IN BERLIN TO SUPPORT THE TALCOTT-SOUTH MOUNTAIN- NEW MILFORD-NEWTOWN OC-3 MICROWAVE EXPANSION REQUESTER: M. CARBARY______MGR. G. BLANCHARD | Benefits-B01 CT13D004 | TALCOTT MOUNTAIN OC-3 MICROWAVE EXP | ADD AN ADDITIONAL OC-3 MICROWAVE HOP BETWEEND TALCOTT MOUNTAIN AND SOUTH MOUNTAIN RADIO SITES. REQUESTER: M. CARBARY______MGR. G. BLANCHARD | Benefits-B01
  4. Part 25 of 77

    CT13D005 | NEWTOWN OC-3 MICROWAVE EXPANSION | ADD AN ADDITIONAL OC-3 MICROWAVE HOP BETWEEND NEW MILFORD AND NEWTOWN RADIO SITES. REQUESTER: M. CARBARY______MGR. G. BLANCHARD | Benefits-B01 CT13D006 | HARTFORD AWC LOWBAND REPEATER SYSTE | REPLACE BASE STATIONS FOR THE HARTFORD TRUCK RADION SYSTEM. THIS WILL REPLACE AGING BASE STATIONS AS WELL AS INCREASE FUNCTIONALITY. PROJECT IT1DWANA | Benefits-B01 CT13D007 | MANCHESTER 3A LOWBAND REPEATER SYST | REPLACE BASE STATIONS FOR THE MAN. 3A TRUCK RADIO SYSTEM. THIS WILL REPLACE AGING BASE STATIONS AS WELL AS INCREASE FUNCTIONALITY. PROJECT IT1DWANA | Benefits-B01 CT13D008 | ROCKY HILL 3R LOWBAND REPEATER SYST | REPLACE BASE STATIONS FOR THE ROCKY HILL 3R RADIO SYSTEM. THIS WILL REPLACE AGING BASE STATIONS AS WELL AS INCREASE FUNCTIONALITY. PROJECT IT1DWANA | Benefits-B01 CT13D009 | TALCOTT MT TS LOWBAND REPEATER SYST | REPLACE BASE STATIONS FOR THE TALCOLT MT RS RADIO SYSTEM. THIS WILL REPLACE AGING BASE STATIONS AS WELL AS INCREASE FUNCTIONALITY. PROJECT IT1DWANA | Benefits-B01 CT13D010 | MIDDLETOWN AWC LOWBAND REPEATER SYS | REPLACE BASE STATIONS FOR THE MIDDLETOWN AWC RADIO SYSTEM. THIS WILL REPLACE AGING BASE STATIONS AS WELL AS INCREASE FUNCTIONALITY. PROJECT IT1DWANA | Benefits-B01 CT13D012 | GREENWICH AWC 10 M ETHERNET | BRING EXPANDED CONNECTIVITY TO THE GREENWICH AWC. THIS WORK ORDER WILL COVER ALL ASSOCIATED EQUIP, CONTRACTOR & LABOR. PROJECT IT1DWANA | Benefits-B01 CT13D015 | UNIION REPLACEMENT TOWER LIGHTS | REPLACEMENT TOWER LIGHTS FOR UNION TOWER . REQUESTER: M. CARBARY PROJECT: IT1DWANA | Benefits-B01 CT13D016 | NEW MILFORD REPLACEMENT TOWER LIGHT | REPLACEMENT TOWER LIGHTS FOR NEW MILFORD TOWER . REQUESTER: M. CARBARY PROJECT: IT1DWANA | Benefits-B01 CT13D017 | GOOSE HILL REPLACEMENT TOWER LIGHTS | REPLACEMENT TOWER LIGHTS FOR GOOSE HILL TOWER . REQUESTER: M. CARBARY PROJECT: IT1DWANA | Benefits-B01 CT13D018 | MANCHESTER REPLACEMENT TOWER LIGHTS | REPLACEMENT TOWER LIGHTS FOR MANCHESTER TOWER . REQUESTER: M. CARBARY PROJECT: IT1DWANA | Benefits-B01 CT13D019 | TALCOTT MT REPLACEMENT TOWER LIGHTS | REPLACEMENT TOWER LIGHTS FOR TALCOTT MTN TOWER . REQUESTER: M. CARBARY PROJECT: IT1DWANA | Benefits-B01 CT14D001 | MADISON AWC - MADISON LOWBAND REPEA | REPLACE BASE STATIONS FOR THE MADISON TRUCK RADIO SYSTEM. THIS WILL REPLACE AGING BASE STATIONS AS WELL AS INCREASE FUNCTIONALITY. PROJECT IT1DWANA | Benefits-B01 CT14D003 | GOOSE HILL RADIO SITE-MADISON LOWBA | REPLACE BASE STATIONS FOR THE MADISON TRUCK TO TRUCK RADIO SYSTEM. THIS WILL REPLACE AGAING BASE STATIONS AS WELL AS INCREASE THE FUNCTIONALITY. PROJECT IT1DWANA | Benefits-B01 CT14D008 | ASENTRIA ALARM REMOTE 4 GOOSE HILL | THE LARSE ALARM RTU IS OBSOLETE AND NEEDS TO BE REPLACED PROJECT IT1DWANA REQUESTER:TOM MULINSKI/WRONA MGR: AHRENS | Benefits-B01 CT14D009 | ASENTRIA ALARM REMOTE FOR STAMFORD | THE LARSE ALARM RTU IS OBSOLETE AND NEEDS TO BE REPLACED_@ 626 GLENBROOK ROAD, STAMFORD PROJECT IT1DWANA REQUESTER:TOM MULINSKI/WRONA MGR: AHRENS | Benefits-B01 CT14D010 | ASENTRIA ALARM REMOTE FOR BERLIN PE | TELECOM ROOM, THE LARSE ALARM RTU IS OBSOLETE AND NEEDS TO BE REPLACED @ 107 SELDEN ST PENTHOUSE LOCATION PROJECT IT1DWANA | Benefits-B01 CT14D011 | ASENTRIA ALARM REMOTE 4 CHESHIRE TE | THE LARSE ALARM RTU IS OBSOLETE AND NEEDS TO BE REPLACED_@ 705 WEST JOHNSON AVE, CHESHIRE (AWC) PROJECT IT1DWANA | Benefits-B01 CT14D030 | BOLTON-E SPRINGFIELD MICROWAVE UPGR | REPLACE EXISTING DVM6-45 EQUIPMENT WHICH IS AT THE END OF ITS USEFUL SERVICE LIFE. REQUESTOR:DOLLY WRONA, MGR: JIM AHRENS Added install / remove waveguid - removal estimated at $7800, new install $5350 | Benefits-B01 CT14D031 | BERLIN TOWARD TALCOTT MICROWAVE UPG | REPLACE EXISTING DVM6-45 EQUIPMENT WHICH IS AT THE END OF ITS USEFUL SERVICE LIFE AT 107 SELDEN STREET, BERLIN, CT CUPOLA AND MUX ROOM | Benefits-B01
  5. Part 26 of 77

    CT14D032 | MANCHESTER MICROWAVE UPGRADE | REPLACE EXISTING DVM6-45 EQUIPMENT WHICH IS AT THE END OF ITS USEFUL SERVICE LIFE AT OLCOTT STREET, MANCHESTER, CT ( MANCHESTER SS LOCATION) | Benefits-B01 CT14D033 | TALCOTT MICROWARE UPGRADE | REPLACE EXISTING DVM6-45 EQUIPMENT WHICH IS AT THE END OF ITS USEFUL SERVICE LIFE AT HOSKINS ROAD, BLOOMFIELD, CT | Benefits-B01 CT14D034 | UNION OC-3 MICROWAVE | PART OF LARGER PROJECT TO REROUTE MICROWAVE NETWORK SERVING HADLEY TO AVOID MT TOM GEN STATION WHICH IS BEING DECOMMISSIONED | Benefits-B01 CT15D001 | Waterbury Portable Radios | This WO will be used to order (10) TK-3180 portable radios that are needed for Waterbury districts operations. | Benefits-B01 CT15D002 | DSCADA DR Telecom - CL&P | This WO will be order various telecom equpiment that is required to have DSCADA DR talk to the various SCADA systems. - CL&P | Benefits-B01 CT15D007 | N LNDN BATTERY & CHRGER BACKUP | New London AWC Battery & Charger install to provide 48v backup for communications equipment | Benefits-B01 CT15D008 | Grounding Upgrade Tower Sites | Site grounding upgrade plus additional ground bars to support microwave equipment and mobile radio for Tower sites | Benefits-B01 CT16D003 | BERLIN SOUTH SITEBOSS INSTALL | Install a SiteBoss alarm panel and remove the old Larse alarm panel in Berlin (NU South) | Benefits-B01 CT16D004 | GOOSE HILL DNX-11 PROTECTION SHELF | Install a protection shelf and card in the Goose Hill DNX-11. Improves reduncancy of system | Benefits-B01 CT16D006 | SO MTN TO SOAPSTONE MICROWAVE UPGR | Upgrade the microwave equipment from DS3 to OC3 capacity to provide sufficient backhaul to enable microwave to be an alternate patch from fiber and increase capacity. | Benefits-B01 CT16D007 | 2016 LOWBAND MOBILE RADIOS | Connecticut Mobile Radios - Statewide initiative - 2016 | Benefits-B01 CT16D019 | BERLIN TO W PEAK MICROW UPGRADE | BERLIN TO WEST PEAK MICROWAVE UPGRADE - Upgrade microwave equipment from DS3 to OC3 capacity to provide sufficient backhaul to Berlin to enable microwave to be an alternate path from fiber and increase capacity. | Benefits-B01 CT16D020 | W Peak to Berlin Microwave Upgrade | WEST PEAK TO BERLIN MICROWAVE UPGRADE - Upgrade the microwave equipment from DS3 to OC3 capacity to provide sufficient backhaul to Berlin to enable microwave to be an alternate path from fiber and increase capacity. | Benefits-B01 CT16D021 | NORWALK PAGING BASE | NORWALK PAGING BASE: Replace the paging base that was installed in the Norwalk Harbor plant with a new base located at the Tindall Ave AWC. Does not include antenna work covered under the tower project. | Benefits-B01 CT16D022 | HADDAM NECK 14B SITEBOSS ALARM | Install a SiteBoss alarm panel and remove the old Larse alarm panel @ Haddam Neck 14B Haddam CT | Benefits-B01 CT16D023 | MILLSTONE 15G SITEBOSS INSTALL ALAR | Install a SiteBoss alarm panel and remove the old Larse alarm panel @ Millstone 15G Waterford CT | Benefits-B01 CT17D001 | 56P BATTERY REPLACEMENT | Replace existing batteries at 56 Prospect Street which have reached end of life. | Benefits-B01 CT17D004 | STAMFORD SHELTER BATTERY REPLACE | Replace existing batteries at Stamford Shelter which have reached end of life. | Benefits-B01 CT17D011 | Stamford AWC DMX Install | Install a DMX fiber mux at the Stamford AWC. Roll services to the new DMX and remove the old comm equipment. | Benefits-B01 CT17D014 | GREENWICH CSP RS SITEBOSS INSTALL | Install a SiteBoss alarm panel and remove the old Badger E500 alarm panel. | Benefits-B01 CT17D016 | SOUTHINGTON SITEBOSS INSTALL | Install a SiteBoss alarm panel and remove the old Badger E500 alarm panel. | Benefits-B01 CT17D018 | WINDSOR DATA CTR SITEBOSS INSTALL | Install a SiteBoss alarm panel and remove the old Badger E500 alarm panel. | Benefits-B01
  6. Part 27 of 77

    CT17D031 | Chapel Hill Paging Base | The existing equipment is at the end of its useful life. New equipment including a superior timing mechanism are proposed. Chapel Hill Rd, Montville | Benefits-B01 CT17D034 | Construction Reps Lowband Radios | A request has come in to order radios for mobile/portable radios to be ordered for certain construction reps who do not currently have radios. These radios are needed for switching per TD800 | Benefits-B01 CTEHI011 | CTE Hardship Inbox 21-07-01; 26 | CTE Hardship Inbox 21-07-01; 26-Balmer | Benefits-B01 CTGRT411 | CT Gross Earnings Tax | CT Gross Earnings Tax-Rose | Benefits-B01 CTLD1DC2 | EQUIPMENT TO PROVIDE 10 MB ETHERNET | PURCHASE AND INSTALL STEEL CONDUIT FOR 10 MB ETHERNET CIRCUIT REQUESTOR-ED ARIOLA - MANAGER GERRY BLANCHARD | Benefits-B01 CTLDA011 | CTE LIDR Administrative Costs | Benefits-B01 CTLID011 | CTE Low Inc Disc Dkt 17-12-03RELL | CTE Low Inc Disc Dkt 17-12-03RELL Motion 51-Balmer | Benefits-B01 CTLIFT23 | New Forklift for CT Dielectrics Lab | This work order will be used to purchase a new electric lift truck. The equipment will be used in the CT Dielectric Lab. The price is estimated at $40,000.00. | Benefits-B01 CTME0111 | CTMEEC | CTMEEC | Benefits-B01 CTREG011 | CT Regulatory Costs | CT Regulatory Costs-Amnott | Benefits-B01 CTRSNWTN | NEWTOWN REG EOC SECURITY | Cyber and physical security for regional EOC's. Security hardware for DSCADA system, installation of security cameras and card readers. NEWTOWN | Benefits-B01 CTRTHTFD | HARTFORD REG EOC TELCOM | TELECOMMUNICATION FOR HARTFORD REGIONAL EOC. LOCAL AND WAN EQUIPMENT TO SUPPORT DSCADA, AVTEK RADIO FIBER OPITC INSTALLATION TO HARTFORD AND ANCILLARY EQUIPMENT | Benefits-B01 CTRTNLND | NEW LONDON REG EOC TELECOM | TELECOMMUNICATION FOR NEW LONDON REGIONAL EOC. LOCAL AND WAN EQUIPMENT TO SUPPORT DSCADA, AVTEK RADIO FIBER OPTIC INSTALLATION TO HARTFORD AND ANCILLARY EQUIPMENT | Benefits-B01 CTRTNWTN | NEWTOWN REG EOC TELECOM | TELECOMMUNICATION FOR NEWTOWN REGIONAL EOC. LOCAL AND WAN EQUIPMENT TO SUPPORT DSCADA, AVTEK RADIO FIBER OPITC INSTALLATION TO HARTFORD AND ANCILLARY EQUIPMENT | Benefits-B01 CTVTN16C | CTVT Wiring 2016 | CTVT Wiring-name change G Flannery | Benefits-B01 DGDFLT11 | ENFIELD, NEVINS, 2, RONALD L MORGAN | This AWO is created to support Maximo functionality which requires an FWO but DG program/project does not. All DG "no fwo needed" will be directed to this AWO as a Maximo "defaultAWO" | Benefits-B01 DISE0011 | Discount Expense | Discount Expense | Benefits-B01 | 43001X DONAT111 | Get Tax Credit-Donation | Get Tax Credit-Donation-Chandler | Benefits-B01 | 4261T0 DRCM0011 | Dist Sta Recloser CM | DRCM0011OPSNTRELEXPENSES11 | Benefits-B01 DSCADA14 | ELEC PROJ DSCADA RETROFITS | PRE- CHECKS TO THE CONTROLS AS WELL AS OTHER CHECKLIST ITEMS THAT MAY NEED TO BE PERFORMED BY THE ELECTRIC MAINTENANCE DEPARTMENT | Benefits-B01 DSCADA2W | DSCADA PROGRAM - WATERBURY DISTRICT | BASE RADIO INSTALLATION DSCADA PROGRAM | Benefits-B01 DSCN0145 | NORTHEAST SIMSBURY 43F - REPL FAILE | ASSUME CHARGES FOR THE REPLACEMENT OF THE FAILED ARI CONDITIONING UNIT. | Benefits-B01 DSCN9166 | SHUNOCK 32P - INSTALL TRANSDUCERS | SHUNOCK 32P - INSTALL TRANSDUCERS _________________________________EG | Benefits-B01 DSEQ8026 | CHIPPEN HILL 15U - REBUILD FAILED B | ASSUME CHARGES FOR THE REBUILD OF THE FAILED SPARE BREAKER. _________________________EG | Benefits-B01 DSEQ8029 | CEDAR HEIGHTS 4R-RPL FAILING ANNUNC | REPLACE FAILING ANNUNCIATOR ___________________________CIR | Benefits-B01 DSHK0011 | Dist Sta Housekeeping | DSHK0011OPSNTRELEXPENSES11 | Benefits-B01 DSIP0011 | Dist Sta Inspect | DSIP0011OPSNTRELEXPENSES11 | Benefits-B01 DSN12044 | (60): Install new breaker. DSN1204 | INSTALL A 25 KV SINGLE-PHASE CABLE AND FUSED CUTOUT TO STATION SERVICE TRANSFORMER INSTALL A 3 INCH STEEL CONDUIT AND 25 KV CABLE FROM THE YARD PAD-MOUNTED 15 MVA STEP-DOWN XFMR | Benefits-B01
  7. Part 28 of 77

    DSN22023 | SOUTH END 1G-REPLC FAILING 1X 2X LT | REPLACE THE FAILING 1X AND 2X LTC CONTROL RELAYS ___________________________________________EZ | Benefits-B01 DSN22043 | (60): Retire Substation, remove all | RETIRE SUBSTATION -ALL OF THE EQUIPMENT INCL- UDING FENCE AND TRAPROCK SHOULD BE REMOVED AND SCRAPPED - UPON COMPLETION THE SITE WILL BE TURNED OVER TO REAL ESTATE TO SELL | Benefits-B01 DSN32010 | (50): Miscellaneous: Remote racking | INSTALLATION OF A REMOTE RACKING UNIT FOR SWITCHGEAR BREAKERS __________________________________________CMK | Benefits-B01 DSN32014 | MOBILE BATT TRLR #16902 - BUILD BAT | BUILD A NEW MOBILE BATTERY TRAILER #16901 __________________________________________JJD | Benefits-B01 DSN32049 | WINSTED 22F - REMOVE FOUNDATION | REMOVE ALL UNUSED FOUNDATIONS SIX INCHES BELOW GRADE ___________________________________________EG | Benefits-B01 DSN32053 | VAN DYKE 12 - REPLACE FAILING CUTOU | REPLACEMENT OF THE FAILING SMD-20 CUTOUTS ON THE 12-3S1-1 AND 12-4S1-1 __________________________________________CMK | Benefits-B01 DSN42001 | MOBILE BATTERY TRAILER 1146364-BUIL | BUILD A NEW MOBILE BATTER TRAILER #1146364 __________________________________________JJD | Benefits-B01 DSN42003 | SOUTH COVENTRY 17Y-REMOVE FENCE & F | REMOVE THE FENCE, FOUNDATIONS & TRAP-ROCK, THE AREA WILL BE LOAMED AND SEEDED TO RETURN IT TO ITS ORIGINAL STATE. THE EQUIPMENT HAS BEEN REMOVED AND THE SITE WILL BE SOLD | Benefits-B01 DSN42020 | SOUTH NAUGATUCK 21L-RPLC FAILING AN | REPLACE THE FAILING 21L-1X ANNUNCIATOR __________________________________________CMK | Benefits-B01 DSN42025 | TORRRINGTON TERMINAL 8A-RPLC LIGHTN | REPLACEMENT OF THE INADEQUATE LIGHTING FIXTURES ___________________________________________EZ | Benefits-B01 DSN42027 | MANCHESTER 3A - REPLACE LIGHTING FI | REPLACEMENT OF THE INADEQUATE LIGHTING FIXTURES ___________________________________________EZ | Benefits-B01 DSN42041 | (50): Install equipment for network | Install equipment for network communications pilot. | Benefits-B01 DSN42046 | Replace Deteriorating Fence | Replacement of the deteriorated fence (appr 100 ft) and gate | Benefits-B01 DSN52002 | Beacon Falls 11N - Replace ATS swit | Beacon Falls 11N - Replace the failing auto-throwover switch. | Benefits-B01 DSN52038 | Noera 13H - Replace the phone circu | Noera 13H - Upgrade the DSCADA equipment to transition the DSCADA system over to the fiber SONET ring. | Benefits-B01 DSN52039 | (50): Install an air conditioning s | Carmel Hill 11S - Install an air conditioning unit. | Benefits-B01 DSN62001 | Chippen Hill 15U LTC control Relay | Chippen Hill 15U - Replace the failing 15U-2X Load Tap Changer control relay. | Benefits-B01 DSN72014 | Arrester replacement on the 11R-1X | Cos Cob 11R - Replace the failing 11R-1X high and low side arresters | Benefits-B01 DSQ32018 | MYSTIC 13K - REPLACE FAILED A/C UNI | REPLACEMENT OF THE FAILED A/C UNIT IN THE CONTROL HOUSE ___________________________________________EG | Benefits-B01 DSQ42012 | EAST BANTAM 19U-RPLC FAILED SWGR W/ | INSTALL A NEW POLE TOP RECLOSER AND CONTROL TO REPLACE/BYPASS THE 19U1 SWITCHGEAR FEEDER POSITION_- ONLY INSTALLING THE RECLOSER WORK ORDER_________________________________EZ | Benefits-B01 DSQ62013 | (50): Flax Hill 24A-3X low side Arr | Flax Hill 24A - REplace the failed 24A-3X low side arresters. | Benefits-B01 DSQ62024 | Replace Failed Relay | Norwalk 9S - Replace the failed 9S-45 SEL-351S relay. | Benefits-B01 DSQ62025 | (50): Battery Charger DSQ62025 | Carmel Hill 11S - Replace the failed battery charger. | Benefits-B01 DSQ62043 | (40): Refinish the 4.8 kV switchgea | Refinish the 4.8 kV switchgear enclosure | Benefits-B01 DSYM0011 | Dispatch - System | DSYM0011OPSNTRELEXPENSES11 | Benefits-B01 DV190E11 | CA AWO CLP-1.90S STOCK | CA AWO CLP-1.90S STOCK | Benefits-B01 DV206E11 | CA AWO CLP$2.06S STOCK | CA AWO CLP$2.06S STOCK | Benefits-B01 DV209E11 | CA AWO CLP$2.09S STOCK | CA AWO CLP$2.09S STOCK | Benefits-B01
  8. Part 29 of 77

    DV390E11 | CA AWO CLP3.90%S STOCK | CA AWO CLP3.90%S STOCK | Benefits-B01 DV450E11 | CA AWO CLP4.50%S STOCK | CA AWO CLP4.50%S STOCK 1951 | Benefits-B01 DV528E11 | CA AWO CLP5.28%S STOCK | CA AWO CLP5.28%S STOCK | Benefits-B01 DV656E11 | CA AWO CLP6.56%S STOCK | CA AWO CLP6.56%S STOCK | Benefits-B01 EEC23001 | Eversource Energy Ctr May 2023 | This AWO is being set up to pay the May 2023 Payment for the Eversource Energy center agreement with UCONN. | Benefits-B01 ELSP0211 | Electric Supply | Electric Supply | Benefits-B01 | 2421H0 EMPP0011 | Emergency Preparedness | EMPP0011OPSNTRELEXPENSES11 | Benefits-B01 ENFLDAW1 | SITE #58 ENFIELD AREA WORK CENTER | REMEDIATION SITE #58 ENFIELD AREA WORK CENTER | Benefits-B01 EPLD0011 | Engineering/Planning/Design | EPLD0011OPSNTRELEXPENSES11 | Benefits-B01 ERRU0011 | Envir Resp/Remediation - Undergrnd | ERRU0011OPSNTRELEXPENSES11 | Benefits-B01 ERRX0011 | Envir Resp/Remediation - Overhead | ERRX0011OPSNTRELEXPENSES11 | Benefits-B01 ESSB0011 | 11 SS Clearing Blanket CT | ESSB0011ALLOCCLEARING11 | Benefits-B01 | 107ES0 ESSL0011 | 11 OH Clearing Blanket CT | ESSL0011ALLOCCLEARING11 | Benefits-B01 | 107ES0 ES_001CS | CHESHIRE AWC ES 140 FT SST | CHESHIRE AWC LOC ES-001 VOICE RADIO SET UP_x000D__x000D_ | Benefits-B01 ETRE0011 | Tree Trimming | ETRE0011NT011 | Benefits-B01 EVTC0011 | Event Sponsorship - Company Funded | EVTC0011NT011 | Benefits-B01 EXCVT101 | 2001 CL&P EXCAVATING CONTRACTOR ARE | WORK ORDER TO COLLECT FOR DISTRIBUTION, CHARGES FROM EXCAVATION CONTRACTS FOR THE 9 CL&P DESIGNATED AREAS - MATERIAL REQUEST # 86884800 AND 15984800 BY D SODERSTROM | Benefits-B01 F1411025 | CL&P Backup SOC | Establishment of CL&P Backup SOC in Windsor | Benefits-B01 F1511011 | Newtown Glygol System | Newtown Glygol System Replacement | Benefits-B01 F1511070 | East Hampton Gate Door Closer | Install Hydraulic Door Closer on Gate Door in East Hampton | Benefits-B01 F1511090 | Hartford Gate Intercom | Hartford Gate Intercom | Benefits-B01 F1611010 | New London Gate Intercom | New London Gate Intercom Replacement | Benefits-B01 F1611014 | Cheshire Security Cameras (4) | Cheshire Security Cameras (4) | Benefits-B01 F1711013 | Myrock Substation Office Fitout | Myrock Substation Office Fitout - Structures | Benefits-B01 FALU0011 | Fault Locating (Underground) | FALU0011OPSNTRELEXPENSES11 | Benefits-B01 FALX0011 | Fault Locating (DB/Overhead) | FALX0011OPSNTRELEXPENSES11 | Benefits-B01 FC161102 | Bunker Hill Tower Radio Equipment | Bunker Hill Tower Radio Equipment - Freight Street Consolidation | Benefits-B01 FC161103 | Waterbury Freight St. Equipment | Waterbury Freight Street Non-Site Specific Equipment | Benefits-B01 FC161104 | Higganum Tower Radio Equipment | Higganum Tower Radio Equipment - Freight Street Consolidation | Benefits-B01 FC161107 | Prospect Tower Radio Equipment | Prospect Tower Radio Equipment - Freight Street Consolidation | Benefits-B01 FC161109 | Southbury Tower Radio Equipment | Southbury Tower Radio Equipment - Freight Street Consolidation | Benefits-B01 FC161110 | Cheshire Tower Radio Equipment | Cheshire Tower Radio Equipment | Benefits-B01 FRMS0011 | Safety/Prot Clothing/Small Tools | Safety/Prot Clothing/Small Tools- Meter Service | Benefits-B01 FRPC0011 | Small Tools Fire Reta/Prot Cloth | FRPC0011NT011 | Benefits-B01 FRPC0111 | Fire Retardant/Protective Clothing | Fire Retardant/Protective Clothing & Safety Supplies | Benefits-B01 GEIA0011 | Generation Interc Agreements | GEIA0011OPSNTRELEXPENSES11 | Benefits-B01 GENE0011 | Generators | GENE0011OPSNTRELEXPENSES11 | Benefits-B01 GOLDC011 | Gold Coast Anniversary Payment | Gold Coast Anniversary Payment | Benefits-B01 | 242GC0 GOOSEHLL | GOOSE HILL MICROWAVE | EAST HAMPTON TOWER REPLACEMENT - MICROWAVE BETWEEN E HAMPTON TOWER AND GOOSE HILL | Benefits-B01 GSUP0011 | General Supplies MDEC | General Supplies MDEC | Benefits-B01
  9. Part 30 of 77

    GX160002 | Mini SF6 Processing Module | Portable mini SF6 processing module includes 16' service hose with Dilo Dn8 couplers requested by John Carroll | Benefits-B01 GX160016 | Fluke Digital Multimeter 87V/E2 | Fluke Digital Multimeter 87V/E2 | Benefits-B01 GX160023 | HEPA Vac | HEPA Vac | Benefits-B01 GX160024 | Hydraulic Hand Pump Kit | Hydraulic Hand Pump Kit part # 0709426 | Benefits-B01 GX160025 | Snow Removal Equipment | Snow removal equipment | Benefits-B01 GX160026 | Projector and Accessories | Snow removal equipment | Benefits-B01 GX160027 | Dynatel Cable Locator | Dynatel Cable Locator | Benefits-B01 GX160030 | Fiber Termination Kit & Blades | Fiber Termination Kit & Blades | Benefits-B01 GX170001 | Nomenclature Printers Durlabel | Duralbel Nomenclature Printers (2) | Benefits-B01 GX170002 | Work Zone Protection Sign Kit FE | Work Zone Protection Sign Kit 10 Stock Code #466238 | Benefits-B01 GX170003 | Greenlee Conduit Bender and Acc | Greenlee Conduit Bender stock code 184031 and Accessories stock code 184032 2 Units | Benefits-B01 GX170007 | DTR 8510 Ratiometer | Chauvin Arnoux High Performance Ratiometer model DTR 8510 for Ct Station Ops East - two units | Benefits-B01 GX210019 | PoleForeman V5.7 - SagLine V3.6 Sof | PoleForeman V5.7- Engineering Analysis Software Site License - CL&P only $136,659_x000D__x000D_ SagLine V3.6 - Engineering Analysis Software Site License - CL&P only $43,155_x000D__x000D_ Requested by Wayne Gagnon_x000D__x000D_ | Benefits-B01 GX210027 | Laptop Vehicle Mounts | Purchase of laptop vehicle mounts; total $125845. 81 units. Supplier Gamber Johnson | Benefits-B01 GXC14W68 | Purchase Epson EX7230 Projector | PURCHASE Epson EX7230 Projector | Benefits-B01 GXC16C22 | 2 x 80" Monitors w/install | to purchase 2 x 80" monitors and move 50" monitor. Service and Installation TOTAL $16,868. | Benefits-B01 GXC16C52 | Hot Line Cutters (4) Begley 2AD | Hot Line Cutters (4) for 2AD OH Chesire s/c188854 @ $1421.13ea TOTAL: $5685 | Benefits-B01 GXC16C61 | Cutter Cable (2) 2NR Engel | 2NR - CUTTER CABLE- 2 - 0445410 $ 2589.23ea TOTAL: $5178.46 | Benefits-B01 GXC16C63 | Pump Hydraulic (2) 2NR Engel | 2NR - PUMP HYDRUICL-2-0448372 $ 2697.00 TOTAL: $5395 | Benefits-B01 GXC16C64 | Potential Tester (2) 2NR Engel | 2NR - POTENTIAL TESTER -2 -0443314 $ 586.93 TOTAL: $1175 | Benefits-B01 GXC16W02 | 42" Samsung Television - $3,362.6 | 2 replacement cutter heads stock code 458692 cost is $553.00 each; 1106 - Pagliaro | Benefits-B01 GXC16W45 | HILTI Impact Drill 549.47 each = 10 | HILTI Impact Drill 549.47 each = 1098.54 | Benefits-B01 GXC17C10 | Pin Pointer w/Battery (1) 2NP Stev | 2NP - (1) Pin pointer / SC 190521 / $ 1,717,00 / (1) Battery for pin pointer / SC 190522 / $266.30 TOTAL: $1987 Enos Stevens | Benefits-B01 GXC17C11 | Chainsaw w/16" Bar 2BB Blair | 2BB - 1 x 3.06 CI Chainsaw w/16" Bar, s/c 465252, TOTAL: $625.00 | Benefits-B01 GXC17C12 | Public Safety Kit w/Defrib (2) 2EB | 2EB - (2) - S/C 460802 DEVICE, PUBLIC SAFETY KIT W/ RX COPY AND PLUSTRAC 5, ZOLL AEDPLUS, DEFRIBULATOR - $1848 each TOTAL: $3696 MANLEY | Benefits-B01 GXC17C13 | Crimper, Die, 6 ton (1) 2BB LaHaie | 2BB - Crimper, Die, 6 ton. S/C 0455630 TOTAL: $1785 LaHaie | Benefits-B01 GXC17C15 | Gas Detector Docking Stat - Stevens | 2NP - (One) Gas Detector Calibration + Bump Docking station SC 0439496 @ $1,982 Enos Stevens | Benefits-B01 GXC17C27 | EZ Squeeze (3) HB Mobility Belt (3) | 2AD - 490DRMS EZ-Squeeze w/ Inner Rope & Snap Hooks (3) @516.16ea / 20182MP3-25BH Heritage Buck Mobilty Belt, 25 DEE, w/ Long Gut Strap, 3 Extra Holes in the Gut Strap. (3) @ 612.50ea TOTAL: $3,400 | Benefits-B01 GXC17C28 | AED (3) 2EK | 2EK - AED S/C 460802 (3) $1,849EA Total: 5547 | Benefits-B01 GXC17C29 | Cutter Heads (3) 2EK | 2EK - Cutter Heads (Candlestick) (3) $500ea TOTAL: 1500 S/C 465047 | Benefits-B01
  10. Part 31 of 77

    GXC17C30 | Reach Desk Veh (4) 2NR Baret | 2NR - ReachDeskSuper-03 Printer Elite for supervisor vehicle. $500 (BARET) TOTAL $2,000_x000D__x000D_ | Benefits-B01 GXC17C31 | UG Harness (1) HEEL 2NR | 2NR - UG Harnesses (1) s/c 462036 @$735ea FEEL | Benefits-B01 GXC17C32 | Filler Valve Assy (6) 2NR Leonard | 2NR - Filler Valve Assy Guage (6) s/c 0445316 804.65ea TOTAL: $4850 Leonard | Benefits-B01 GXC17C33 | Hilti Rotary Drill (1) 2NR Leonard | 2NR - Hilti Rotary Drill (1) s/c 0441221 TOTAL: $889 Leonard | Benefits-B01 GXC17C34 | Buck Fit Harness/EZ Squeeze Kit (1) | 2AD - Buck Fit Harness M (1) @ $523.18 / EZ Squeeze Kit @ $871.12 TOTAL: $1400 | Benefits-B01 GXCOS70A | SOC MONITOR | WORK ORDER FOR 2017 SOC MONITOR | Benefits-B01 GXCOS70B | DISTRIBUTION SIMULATION/TRAINING RM | Costs to cover the remodel work needed to convert the CONVEX Off-shift Operator Room into a Distribution Simulator Training Classroom. _x000D__x000D_ Estimated costs: $25k (requestor: Bill Newport)_x000D__x000D_ Red Thread (furniture repair, reconfiguration and new): $4,000_x000D__x000D_ A/Z: HVAC, electrical work, data wiring, window treatments, etc.: $20,000_x000D__x000D_ | Benefits-B01 GXENG16A | PLC TT TRAINING GRIDEDGE | TRAINING SETUP EQUIPMENT AND LABOR FOR PLC TT TRAINING. GRIDEDGE IS THE VENDOR W QUOTE OF $23,475. | Benefits-B01 GXENG16B | PROJECTOR FOR SYSTEM RESILIENCY | PURCHASE A PROJECTOR FOR THE SYSTEM RESILIENCY GROUP | Benefits-B01 HAND0011 | Material Handling | HAND0011NT011 | Benefits-B01 HQDC0111 | H/Q Phase 2-DC | H/Q Phase 2-DC | Benefits-B01 HQNET111 | H/Q Phase 1-DC-NEET | H/Q Phase 1-DC-NEET | Benefits-B01 HQVET111 | H/Q Phase 1-DC-VET | H/Q Phase 1-DC-VET | Benefits-B01 HUTP0011 | Highway Use Tax Payment | Highway Use Tax Payment | Benefits-B01 ICBAP011 | ICB Work Order | ICB Work Order-McDonald | Benefits-B01 | 23401X INCW0011 | Inclement Weather | INCW0011OPSNTRELEXPENSES11 | Benefits-B01 INSPC2AD | 2020 FAULT INDICATOR CHESHIRE 2AD | THIS IS PART OF THE DB FAULT INDICATOR INSPECTION AND REPLACEMENT PROGRAM FOR 2020 | Benefits-B01 INTOHE11 | CA AWO INTEREST OTHER | CA AWO INTEREST OTHER | Benefits-B01 IRMT0011 | Install & Remove Meters | IRMT0011OPSNTRELEXPENSES11 | Benefits-B01 ISOV0011 | Inspect- Overhead | ISOV0011 | Benefits-B01 ISPL0011 | Inspect - Poles | ISPL0011OPSNTRELEXPENSES11 | Benefits-B01 ISSB0011 | Inspect Bulk Stations | Inspect Bulk Stations | Benefits-B01 ISST0011 | Inspect Distribution Stations | Inspect Distribution Stations | Benefits-B01 ISSV0011 | Inspect - Stray Voltage | ISSV0011OPSNTRELEXPENSES11 | Benefits-B01 ISTA0011 | Dist Sta Misc PM | ISTA0011OPSNTRELEXPENSES11 | Benefits-B01 ISTE0011 | Inspect/Test Environmental | ISTE0011 | Benefits-B01 ISUN0011 | Inspect - Underground | ISUN0011OPSNTRELEXPENSES11 | Benefits-B01 IT1D1303 | CL&P WIRELESS PROJECT | CL&P WIRELESS PROJECT CISCO EQUIPMENT - NWN QUOTE OP81290 CONTACT: BOB D'EON X3094 PROJECT: IT1DLANA | Benefits-B01 ITRU0011 | Install Transform Regula undergrnd | ITRU0011OPSNTRELEXPENSES11 | Benefits-B01 IVCL0011 | Invoice Clearing | IVCL0011NT011 | Benefits-B01 KICK0011 | Kick Out Corrections | Waiting for kick out reclass | Benefits-B01 LDSM0011 | Locate/DigSafe/Markout | LDSM0011OPSNTRELEXPENSES11 | Benefits-B01 LEAS0011 | Lease | LEAS0011NT011 | Benefits-B01 | 232PA0 LGFR0011 | Federal Regulatory | LGFR0011NT011 | Benefits-B01 LGLT0011 | Litigation | LGLT0011NT011 | Benefits-B01 LGSR0011 | State Regulatory | LGSR0011NT011 | Benefits-B01 LNGT1DC3 | LONG HILL - FREIGHT STREET WORK | LONG HILL - FREIGHT STREET WORK AS PART OF THE LONG HILL TOWER MOVE EQUIPMENT WILL BE PURCHASED FOR THE FREIGHT STREET SITE AS WELL AS LABOR TO INSTALL. | Benefits-B01 LOBBY011 | Lobby Stock Clearing | LOBBY011ALLOCCLEARING11 | Benefits-B01 LTDB0711 | Long Term Debt2004 Series A | Long Term Debt2004 Series A | Benefits-B01 | 237CD0 LTDB1011 | Long Term Debt2005 Series A | Long Term Debt2005 Series A | Benefits-B01 | 237CP0

Text of RRU-159 Attachment 03.pdf

Extracted from the file · 840 pages · 14,413,580 characters

Text of RRU-159 Attachment 02.xlsx

Sheet names, column headings and text cells; numbers left out · first 300,000 characters

Text of RRU-159 Attachment 02.pdf

Extracted from the file · 1,137 pages · 16,605,462 characters

Text of RRU-159 Attachment 01.xlsx

Sheet names, column headings and text cells; numbers left out

Text of RRU-159 Attachment 01.pdf

Extracted from the file · 1 page · 1,403 characters

As listed on the current system

Question(s) Answered 159 (Connecticut Light and Power Company dba Eversource Energy) Date Filed: 11/06/2026

This filing on the current system (opens in a new tab)