Interrogatory responses
Answers to questions 29, 30, 32, 36, 39, 40
Files10
RRU-029_Final.pdf
PDF · 89 KB · 1 pageText searchable
Download RRU-029_Final.pdfRead the text of RRU-029_Final.pdf
RRU-030_Final.pdf
PDF · 94 KB · 2 pagesText searchable
Download RRU-030_Final.pdfRead the text of RRU-030_Final.pdf
RRU-032_Final.pdf
PDF · 83 KB · 1 pageText searchable
Download RRU-032_Final.pdfRead the text of RRU-032_Final.pdf
RRU-036_Final.pdf
PDF · 83 KB · 1 pageText searchable
Download RRU-036_Final.pdfRead the text of RRU-036_Final.pdf
RRU-039_Final.pdf
PDF · 143 KB · 3 pagesText searchable
Download RRU-039_Final.pdfRead the text of RRU-039_Final.pdf
RRU-039 Attachment 1.pdf
PDF · 73 KB · 1 pageText searchable
Download RRU-039 Attachment 1.pdfRead the text of RRU-039 Attachment 1.pdf
RRU-039 Attachment 1.xlsx
Excel · 37 KBText searchable
Download RRU-039 Attachment 1.xlsxRead the text of RRU-039 Attachment 1.xlsx
RRU-040_Final.pdf
PDF · 117 KB · 2 pagesText searchable
Download RRU-040_Final.pdfRead the text of RRU-040_Final.pdf
RRU-040 Attachment 1.pdf
PDF · 103 KB · 1 pageText searchable
Download RRU-040 Attachment 1.pdfRead the text of RRU-040 Attachment 1.pdf
RRU-040 Attachment 1.xlsx
Excel · 22 KBText searchable
Download RRU-040 Attachment 1.xlsxRead the text of RRU-040 Attachment 1.xlsx
Page 1
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set PURA-05 Date Issued September 08, 2026 RRU-036 Page 1 of 1 Date Filed: September 22, 2026 Witness: Amparo Nieto Request from: Public Utilities Regulatory Authority Question: (MCOS) Application, Ex. CLP-MCOS-1, Dir. Test. Nieto, p. 14. Explain the phrase “the large differential suggests an excessive incentive to conserve”. Specifically, conserve what? Response: The statement refers to an excessive (not cost-reflective) incentive to conserve electricity usage, due to the per-kWh charges currently recovering well in excess of the estimated system-wide marginal cost of serving an additional kWh. Such excessive unit cost essentially means that customers who desire to electrify space heating or add other electric loads may either face a higher bill, where the change in their bills exceeds the change in cost to the utility to serve the additional electricity. The customer, may alternatively decide against expanding electricity even though that additional usage would have provided value to the customer that exceeds the cost for the utility to serve. This is an inefficient outcome.
Text of RRU-039_Final.pdf
Extracted from the file · 3 pages · 3,379 characters
Text of RRU-039 Attachment 1.pdf
Extracted from the file · 1 page · 2,139 characters
Text of RRU-039 Attachment 1.xlsx
Sheet names, column headings and text cells; numbers left out
Text of RRU-040_Final.pdf
Extracted from the file · 2 pages · 4,944 characters
Text of RRU-040 Attachment 1.pdf
Extracted from the file · 1 page · 464 characters
Text of RRU-040 Attachment 1.xlsx
Sheet names, column headings and text cells; numbers left out
As listed on the current system
Question(s) Answered 29, 30, 32, 36, 39, 40 (The Connecticut Light and Power Company) Date Filed: 09/22/2026