  1. Page 336 of 754

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-032 Attachment 176 Page 446 of 864 CET # : 24F0174 Project: Eversource Blue Hills 6WM, Windsor Project Number: 23246-8B SAMPLE SUMMARY The sample(s) were received at 5.0 C. This report contains analytical data associated with following samples only. Sample ID Laboratory ID Matrix Collection Date/Time Receipt Date B44 2-4ft B42 0-2ft 24F0174-01 24F0174-02 Soil Soil 5/21/2024 11:58 5/21/2024 13:25 05/22/2024 05/22/2024 Analyst: JF Analyte: Percent Solids [SM 2540 G] Matrix: Soil Date/Time Laboratory ID Client Sample ID 24F0174-01 B44 2-4ft 24F0174-02 B42 0-2ft Notes Result RL Units Dilution Batch Prepared 72 1.0 % 1 BF40750 06/07/2024 06/10/2024 11:50 1.0 % 1 BF40750 06/07/2024 06/10/2024 11:50 88 Analyzed Analyst: GEH Analyte: Mercury [EPA 7471B] Matrix: Soil Date/Time Laboratory ID Client Sample ID 24F0174-01 B44 2-4ft 24F0174-02 B42 0-2ft Result ND ND RL Units Dilution Batch Prepared 0.16 mg/kg dry 1 BF41005 06/10/2024 06/10/2024 14:43 0.14 mg/kg dry 1 BF41005 06/10/2024 06/10/2024 14:46 Analyzed Notes Complete Environmental Testing, Inc. 80 Lupes Drive, Stratford, CT 06615 • Tel: [phone removed] • Fax: [phone removed] • www.cetlabs.com Page 2 of 13
  2. Page 337 of 754

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-032 Attachment 176 Page 447 of 864 CET # : 24F0174 Project: Eversource Blue Hills 6WM, Windsor Project Number: 23246-8B Client Sample ID B44 2-4ft Lab ID: 24F0174-01 Total Metals Analyst: SS Method: EPA 6010D Matrix: Soil Result Analyte RL Date/Time (mg/kg dry) (mg/kg dry) Dilution Prep Method Batch Prepared Analyzed Lead 48 2.6 1 EPA 3051A BF41034 06/10/2024 06/11/2024 11:38 Selenium ND 3.2 1 EPA 3051A BF41034 06/10/2024 06/11/2024 11:38 Cadmium ND 0.64 1 EPA 3051A BF41034 06/10/2024 06/11/2024 11:38 Chromium 12 2.6 1 EPA 3051A BF41034 06/10/2024 06/11/2024 11:38 Arsenic 3.6 1.3 1 EPA 3051A BF41034 06/10/2024 06/11/2024 11:38 Barium 34 2.6 1 EPA 3051A BF41034 06/10/2024 06/11/2024 11:38 Silver ND 2.6 1 EPA 3051A BF41034 06/10/2024 06/11/2024 11:38 Copper 10 2.6 1 EPA 3051A BF41034 06/10/2024 06/11/2024 11:38 Nickel 7.4 2.6 1 EPA 3051A BF41034 06/10/2024 06/11/2024 11:38 Zinc 54 2.6 1 EPA 3051A BF41034 06/10/2024 06/11/2024 11:38 Notes Client Sample ID B42 0-2ft Lab ID: 24F0174-02 Total Metals Analyst: SS Method: EPA 6010D Matrix: Soil Result Analyte RL (mg/kg dry) (mg/kg dry) Date/Time Dilution Prep Method Batch Prepared Analyzed Lead 10 2.1 1 EPA 3051A BF41034 06/10/2024 06/11/2024 11:42 Selenium ND 2.6 1 EPA 3051A BF41034 06/10/2024 06/11/2024 11:42 Cadmium ND 0.52 1 EPA 3051A BF41034 06/10/2024 06/11/2024 11:42 Chromium 11 2.1 1 EPA 3051A BF41034 06/10/2024 06/11/2024 11:42 Arsenic 2.3 1.0 1 EPA 3051A BF41034 06/10/2024 06/11/2024 11:42 Barium 20 2.1 1 EPA 3051A BF41034 06/10/2024 06/11/2024 11:42 Silver ND 2.1 1 EPA 3051A BF41034 06/10/2024 06/11/2024 11:42 Copper 19 2.1 1 EPA 3051A BF41034 06/10/2024 06/11/2024 11:42 Nickel 7.5 2.1 1 EPA 3051A BF41034 06/10/2024 06/11/2024 11:42 Zinc 36 2.1 1 EPA 3051A BF41034 06/10/2024 06/11/2024 11:42 Notes Complete Environmental Testing, Inc. 80 Lupes Drive, Stratford, CT 06615 • Tel: [phone removed] • Fax: [phone removed] • www.cetlabs.com Page 3 of 13
  3. Page 338 of 754

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-032 Attachment 176 Page 448 of 864 CET # : 24F0174 Project: Eversource Blue Hills 6WM, Windsor Project Number: 23246-8B QUALITY CONTROL SECTION Batch BF40750 - SM 2540 G Analyte Result (%) Duplicate (BF40750-DUP1) Percent Solids RL (%) Spike Level Source Result 1.0 % Rec Limits RPD RPD Limit Notes Prepared: 6/7/2024 Analyzed: 6/10/2024 Source: 24F0174-02 89 % Rec 88 0.268 5 Complete Environmental Testing, Inc. 80 Lupes Drive, Stratford, CT 06615 • Tel: [phone removed] • Fax: [phone removed] • www.cetlabs.com Page 4 of 13
  4. Page 339 of 754

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-032 Attachment 176 Page 449 of 864 CET # : 24F0174 Project: Eversource Blue Hills 6WM, Windsor Project Number: 23246-8B Batch BF41005 - EPA 7471B Analyte Result (mg/kg) RL (mg/kg) ND 0.13 1.26 0.13 Spike Level Source Result 1.250 RPD Limit Notes 101 80 - 120 Prepared: 6/10/2024 Analyzed: 6/10/2024 LCS Dup (BF41005-BSD1) Mercury RPD Prepared: 6/10/2024 Analyzed: 6/10/2024 LCS (BF41005-BS1) Mercury % Rec Limits Prepared: 6/10/2024 Analyzed: 6/10/2024 Blank (BF41005-BLK1) Mercury % Rec 1.24 0.13 1.250 99.5 80 - 120 1.68 20 Complete Environmental Testing, Inc. 80 Lupes Drive, Stratford, CT 06615 • Tel: [phone removed] • Fax: [phone removed] • www.cetlabs.com Page 5 of 13
  5. Page 340 of 754

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-032 Attachment 176 Page 450 of 864 CET # : 24F0174 Project: Eversource Blue Hills 6WM, Windsor Project Number: 23246-8B Batch BF41034 - EPA 6010D Analyte Result (mg/kg) RL (mg/kg) Spike Level ND ND ND ND ND ND ND ND ND ND 2.0 2.5 0.50 2.0 1.0 2.0 2.0 2.0 2.0 2.0 238 106 179 187 167 387 57.9 195 102 238 2.0 2.5 0.50 2.0 1.0 2.0 2.0 2.0 2.0 2.0 261.000 117.000 199.000 210.000 180.000 431.000 65.500 229.000 108.000 264.000 233 103 178 183 164 366 55.9 191 101 233 2.0 2.5 0.50 2.0 1.0 2.0 2.0 2.0 2.0 2.0 261.000 117.000 199.000 210.000 180.000 431.000 65.500 229.000 108.000 264.000 Source Result RPD Limit Notes 91.1 90.3 89.8 89.2 93.0 89.9 88.4 85.3 94.8 90.1 78 - 114 83 - 127 84 - 119 80 - 117 87 - 127 81 - 114 83 - 127 79 - 110 79 - 114 82 - 121 Prepared: 6/10/2024 Analyzed: 6/11/2024 LCS Dup (BF41034-BSD1) Lead Selenium Cadmium Chromium Arsenic Barium Silver Copper Nickel Zinc RPD Prepared: 6/10/2024 Analyzed: 6/11/2024 LCS (BF41034-BS1) Lead Selenium Cadmium Chromium Arsenic Barium Silver Copper Nickel Zinc % Rec Limits Prepared: 6/10/2024 Analyzed: 6/11/2024 Blank (BF41034-BLK1) Lead Selenium Cadmium Chromium Arsenic Barium Silver Copper Nickel Zinc % Rec 89.2 88.2 89.2 87.0 90.9 84.8 85.3 83.6 93.2 88.1 78 - 114 83 - 127 84 - 119 80 - 117 87 - 127 81 - 114 83 - 127 79 - 110 79 - 114 82 - 121 2.04 2.39 0.730 2.43 2.30 5.79 3.55 2.02 1.67 2.25 30 30 30 30 30 30 30 30 30 30 Complete Environmental Testing, Inc. 80 Lupes Drive, Stratford, CT 06615 • Tel: [phone removed] • Fax: [phone removed] • www.cetlabs.com Page 6 of 13
  6. Page 341 of 754

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-032 Attachment 176 Page 451 of 864 CET # : 24F0174 Project: Eversource Blue Hills 6WM, Windsor Project Number: 23246-8B All questions related to this report should be directed to David Ditta, Timothy Fusco, or Robert Blake at [phone removed]. Sincerely, David Ditta Laboratory Director This technical report was reviewed by Timothy Fusco Project Manager This report shall not be reproduced except in full, without the written approval of the laboratory Report Comments: Sample Result Flags: E- The result is estimated, above the calibration range. H- The surrogate recovery is above the control limits. L- The surrogate recovery is below the control limits. B- The compound was detected in the laboratory blank. P- The Relative Percent Difference (RPD) of dual column analyses exceeds 40%. D- The RPD between the sample and the sample duplicate is high. Sample Homogeneity may be a problem. +- The Surrogate was diluted out. *C1- The Continuing Calibration did not meet method specifications and was biased low for this analyte. Increased uncertainty is associated with the reported value which is likely to be biased low. *C2- The Continuing Calibration did not meet method specifications and was biased high for this analyte. Increased uncertainty is associated with the reported value which is likely to be biased high. *F1- The Laboratory Control Sample recovery is outside of control limits. Reported value for this analyte is likely to be biased on the low side. *F2- The Laboratory Control Sample recovery is outside of control limits. Reported value for this analyte is likely to be biased on the high side. *I- Analyte exceeds method limits from second source standard in Initial Calibration Verification (ICV). No directional bias. All results met standard operating procedures unless indicated by a data qualifier next to a sample result, or a narration in the QC report. For Percent Solids, if any of the following prep methods (3050B, 3540C, 3545A, 3550C, 5035 and 9013A) were used for samples pertaining to this report, the percent solids procedure is within that prep method. Complete Environmental Testing is only responsible for the certified testing and is not directly responsible for the integrity of the sample before laboratory receipt. ND is None Detected at or above the specified reporting limit Reporting Limit (RL) is the limit of detection for an analyte after any adjustment made for dilution or percent moisture. All analyses were performed in house unless a Reference Laboratory is listed. Samples will be disposed of 30 days after the report date. Complete Environmental Testing, Inc. 80 Lupes Drive, Stratford, CT 06615 • Tel: [phone removed] • Fax: [phone removed] • www.cetlabs.com Page 7 of 13
  7. Page 342 of 754

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-032 Attachment 176 Page 452 of 864 CET # : 24F0174 Project: Eversource Blue Hills 6WM, Windsor Project Number: 23246-8B Tel: [phone removed] Fax: [phone removed] email: [email removed] 80 Lupes Drive Stratford, CT 06615 Quality Control Definitions and Abbreviations Internal Standard (IS) Surrogate Recovery Continuing Calibration Batch ND RL Dilution Duplicate Result Spike Level Matrix Spike Result Matrix Spike Dup Matrix Spike % Recovery Matrix Spike Dup % Recovery RPD Blank LCS % Recovery Recovery Limits CC An Analyte added to each sample or sample extract. An internal standard is used to monitor retention time, calculate relative response, and quantify analytes of interest. The % recovery for non-target organic compounds that are spiked into all samples. Used to determine method performance. An analytical standard analyzed with each set of samples to verify initial calibration of the system. Samples that are analyzed together with the same method, sequence and lot of reagents within the same time period. Not detected at or above the specified reporting limit. RL is the limit of detection for an analyte after any adjustment made for dilution or percent moisture. Multiplier added to detection levels (MDL) and/or sample results due to interferences and/or high concentration of target compounds. Result from the duplicate analysis of a sample. Amount of analyte found in a sample. Amount of analyte added to a sample Amount of analyte found including amount that was spiked. Amount of analyte found in duplicate spikes including amount that was spike. % Recovery of spiked amount in sample. % Recovery of spiked duplicate amount in sample. Relative percent difference between Matrix Spike and Matrix Spike Duplicate. Method Blank that has been taken through all steps of the analysis. Laboratory Control Sample percent recovery. The amount of analyte recovered from a fortified sample. A range within which specified measurements results must fall to be compliant. Calibration Verification Flags: HLBP#- Recovery is above the control limits Recovery is below the control limits Compound detected in the Blank RPD of dual column results exceeds 40% Sample result too high for accurate spike recovery. Connecticut Laboratory Certification PH0116 Massachussets Laboratory Certification M-CT903 Pennsylvania NELAP Accreditation 68-02927 New York NELAP Accreditation 11982 Rhode Island Certification 199 Complete Environmental Testing, Inc. 80 Lupes Drive, Stratford, CT 06615 • Tel: [phone removed] • Fax: [phone removed] • www.cetlabs.com Page 8 of 13
  8. Page 343 of 754

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-032 Attachment 176 Page 453 of 864 Bureau of Water Protection and Land Reuse Remediation Division REASONABLE CONFIDENCE PROTOCOL LABORATORY ANALYSIS QA/QC CERTIFICATION FORM Laboratory Name: Complete Environmental Testing, Inc. Client: Zuvic Inc. Project Location: Eversource Blue Hills 6WM, Windsor Project Number: 23246-8B Sample Date(s): Laboratory Sample ID(s): 05/21/2024 24F0174-01 thru 24F0174-02 List RCP Methods Used: EPA 6010D, EPA 7471B 1 For each analytical method referenced in this laboratory report package, were all specified QA/QC performance criteria followed, including the requirement to explain any criteria falling outside of acceptable guidelines, as specified in the CTDEP method-specific Reasonable Confidence Protocol documents? 1A Were the method-specified preservation and holding time requirements met? 1B VPH and EPH Methods Only: Was the VPH or EPH method conducted without significant modifications (See respective RCPs) 2 Were all samples received by the laboratory in a condition consistent with that described on the associated chain-of-custody document(s)? 3 Were samples received at an appropriate temperature (<6° C)? If samples were received by the laboratory on the same day of collection and were stored and transported to the laboratory on ice, cooler temperatures above 6°C are acceptable. ü Yes No ü Yes No Yes No ü N/A ü Yes ü Yes No No N/A ü Yes No Were reporting limits / limits of quantitation specified or referenced on the chain-of-custody? ü Yes No 5a Were these reporting limits / limits of quantitation met? ü Yes No 6 For each analytical method referenced in this laboratory report package, were results reported for all constituents identified in the method-specific analyte lists presented in the Reasonable Confidence Protocol documents? Yes ü No 7 Are project-specific matrix spikes and laboratory duplicates included in this data set for applicable RCPs? Yes ü No 4 Were all QA/QC performance criteria specified in the CT DEEP Reasonable Confidence Protocol documents achieved? 5 Notes: For all questions to which the response was “No” (with the exception of question #7), additional information must be provided in an attached narrative. If the answer to question #1, #1A, or #1B is “No”, the data package does not meet the requirements for “Reasonable Confidence. ” This form may not be altered, and all questions must be answered. I, the undersigned, attest under the pains and penalties of perjury that, to the best of my knowledge and belief and based upon my personal inquiry of those responsible for providing the information contained in this analytical report, such information is accurate and complete. Authorized Signature: Position: Laboratory Director Printed Name: David Ditta Date: 06/11/2024 Name of Laboratory: Complete Environmental Testing, Inc. This certification form is to be used for RCP methods only. RCP QA/QC Certficication Form Version 2024 Page 9 of 13
  9. Page 344 of 754

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-032 Attachment 176 Page 454 of 864 RCP Case Narrative 6- Client requested a subset of the RCP Metals list. 7- Project specific QC was not requested by the client. QC Batch/Sequence Report Batch Sequence CET ID Sample ID Specific Method Matrix Collection Date BF41034 S4F1102 24F0174-01 B44 2-4ft EPA 6010D Soil 05/21/2024 BF41034 S4F1102 24F0174-02 B42 0-2ft EPA 6010D Soil 05/21/2024 BF41005 24F0174-01 B44 2-4ft EPA 7471B Soil 05/21/2024 BF41005 24F0174-02 B42 0-2ft EPA 7471B Soil 05/21/2024 RCP QA/QC Certficication Form Version 2024 Page 10 of 13
  10. Page 345 of 754

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-032 Attachment 176 Page 455 of 864 Page 11 of 13

Text of RSR-032 Attachment 176_Part1.pdf

Extracted from the file · 110 pages · 439,601 characters

Text of RSR-032 Attachment 175_Part7.pdf

Extracted from the file · 275 pages · 622,526 characters

Text of RSR-032 Attachment 175_Part6.pdf

Extracted from the file · 350 pages · 828,421 characters

Text of RSR-032 Attachment 175_Part5.pdf

Extracted from the file · 350 pages · 841,526 characters

Text of RSR-032 Attachment 175_Part4.pdf

Extracted from the file · 350 pages · 529,828 characters

Text of RSR-032 Attachment 175_Part3.pdf

Extracted from the file · 350 pages · 417,827 characters

Text of RSR-032 Attachment 175_Part2.pdf

Extracted from the file · 350 pages · 717,402 characters

Text of RSR-032 Attachment 175_Part1.pdf

Extracted from the file · 350 pages · 426,888 characters

Text of RSR-032 Attachment 174.pdf

Extracted from the file · 2 pages · 3,788 characters

Text of RSR-032 Attachment 173.pdf

Extracted from the file · 9 pages · 19,276 characters

Text of RSR-032 Attachment 172.pdf

Extracted from the file · 2 pages · 5,216 characters

Text of RSR-032 Attachment 171.pdf

Extracted from the file · 2 pages · 7,025 characters

Text of RSR-032 Attachment 170.pdf

Extracted from the file · 4 pages · 596 characters

Text of RSR-032 Attachment 169.pdf

Extracted from the file · 14 pages · 2,105 characters

Text of RSR-032 Attachment 168.pdf

Extracted from the file · 178 pages · 303,260 characters

Text of RSR-032 Attachment 167_Part2.pdf

Extracted from the file · 844 pages · 1,367,165 characters

Text of RSR-032 Attachment 167_Part1.pdf

Extracted from the file · 284 pages · 480,797 characters

Text of RSR-032 Attachment 166.pdf

Extracted from the file · 4 pages · 5,984 characters

Text of RSR-032 Attachment 165_Part 4.pdf

Extracted from the file · 84 pages · 130,960 characters

Text of RSR-032 Attachment 165_Part 3.pdf

Extracted from the file · 482 pages · 674,897 characters

Text of RSR-032 Attachment 165_Part 2.pdf

Extracted from the file · 509 pages · 549,394 characters

Text of RSR-032 Attachment 165_Part 1.pdf

Extracted from the file · 500 pages · 578,799 characters

Text of RSR-032 Attachment 164.pdf

Extracted from the file · 42 pages, 16 without text · 66,266 characters

Text of RSR-032 Attachment 163.pdf

Extracted from the file · 575 pages · 624,136 characters

Text of RSR-032 Attachment 162.pdf

Extracted from the file · 17 pages · 19,879 characters

Text of RSR-032 Attachment 161 _Part2.pdf

Extracted from the file · 609 pages · 625,572 characters

Text of RSR-032 Attachment 161 _Part1.pdf

Extracted from the file · 131 pages · 171,359 characters

Text of RSR-032 Attachment 160.pdf

Extracted from the file · 56 pages · 84,793 characters

Text of RSR-032 Attachment 159.pdf

Extracted from the file · 97 pages · 159,126 characters

Text of RSR-032 Attachment 158.pdf

Extracted from the file · 54 pages · 96,528 characters

Text of RSR-032 Attachment 157.pdf

Extracted from the file · 261 pages · 326,004 characters

Text of RSR-032 Attachment 156.pdf

Extracted from the file · 74 pages · 99,158 characters

Text of RSR-032 Attachment 155.pdf

Extracted from the file · 40 pages · 40,141 characters

Text of RSR-032 Attachment 154.pdf

Extracted from the file · 37 pages · 59,275 characters

Text of RSR-032 Attachment 153.pdf

Extracted from the file · 61 pages · 86,468 characters

Text of RSR-032 Attachment 152.pdf

Extracted from the file · 126 pages · 258,689 characters

Text of RSR-032 Attachment 151.pdf

Extracted from the file · 340 pages · 405,994 characters

Text of RSR-032 Attachment 150.pdf

Extracted from the file · 33 pages · 27,344 characters

Text of RSR-032 Attachment 149.pdf

Extracted from the file · 47 pages · 51,678 characters

Text of RSR-032 Attachment 148.pdf

Extracted from the file · 52 pages · 65,933 characters

Text of RSR-032 Attachment 147.pdf

Extracted from the file · 136 pages · 187,807 characters

Text of RSR-032 Attachment 146.pdf

Extracted from the file · 211 pages · 257,714 characters

Text of RSR-032 Attachment 145.pdf

Extracted from the file · 58 pages · 84,698 characters

Text of RSR-032 Attachment 144.pdf

Extracted from the file · 31 pages · 57,751 characters

Text of RSR-032 Attachment 143.pdf

Extracted from the file · 30 pages · 51,258 characters

Text of RSR-032 Attachment 142.pdf

Extracted from the file · 33 pages · 29,732 characters

Text of RSR-032 Attachment 141.pdf

Extracted from the file · 578 pages · 899,265 characters

Text of RSR-032 Attachment 140.pdf

Extracted from the file · 26 pages · 45,518 characters

Text of RSR-032 Attachment 139.pdf

Extracted from the file · 29 pages · 58,671 characters

Text of RSR-032 Attachment 138.pdf

Extracted from the file · 24 pages · 44,766 characters

Text of RSR-032 Attachment 137.pdf

Extracted from the file · 54 pages · 85,922 characters

Text of RSR-032 Attachment 136.pdf

Extracted from the file · 618 pages · 1,036,591 characters

Text of RSR-032 Attachment 135.pdf

Extracted from the file · 52 pages · 107,952 characters

Text of RSR-032 Attachment 134.pdf

Extracted from the file · 57 pages · 119,843 characters

Text of RSR-032 Attachment 133.pdf

Extracted from the file · 82 pages · 196,725 characters

Text of RSR-032 Attachment 132.pdf

Extracted from the file · 137 pages · 251,594 characters

Text of RSR-032 Attachment 131.pdf

Extracted from the file · 7 pages · 1,043 characters

Text of RSR-032 Attachment 130.pdf

Extracted from the file · 847 pages · 1,478,588 characters

Text of RSR-032 Attachment 129.pdf

Extracted from the file · 124 pages · 255,121 characters

Text of RSR-032 Attachment 128.pdf

Extracted from the file · 104 pages · 208,223 characters

Text of RSR-032 Attachment 127.pdf

Extracted from the file · 125 pages · 243,340 characters

Text of RSR-032 Attachment 126.pdf

Extracted from the file · 128 pages · 264,919 characters

Text of RSR-032 Attachment 125.pdf

Extracted from the file · 824 pages · 1,180,085 characters

Text of RSR-032 Attachment 124.pdf

Extracted from the file · 28 pages · 47,835 characters

Text of RSR-032 Attachment 123.pdf

Extracted from the file · 29 pages · 4,370 characters

Text of RSR-032 Attachment 122.pdf

Extracted from the file · 29 pages · 4,370 characters

Text of RSR-032 Attachment 121.pdf

Extracted from the file · 50 pages · 7,541 characters

Text of RSR-032 Attachment 120.PDF

Extracted from the file · 2 pages · 3,192 characters

Text of RSR-032 Attachment 119_Part3.pdf

Extracted from the file · 105 pages · 238,387 characters

Text of RSR-032 Attachment 119_Part2.pdf

Extracted from the file · 169 pages · 372,755 characters

Text of RSR-032 Attachment 119_Part1.pdf

Extracted from the file · 51 pages · 61,331 characters

Text of RSR-032 Attachment 118_Part6.pdf

Extracted from the file · 54 pages · 47,246 characters

Text of RSR-032 Attachment 118_Part5.pdf

Extracted from the file · 254 pages · 39,246 characters

Text of RSR-032 Attachment 118_Part4.pdf

Extracted from the file · 378 pages · 97,273 characters

Text of RSR-032 Attachment 118_Part3.pdf

Extracted from the file · 218 pages · 519,182 characters

Text of RSR-032 Attachment 118_Part2.pdf

Extracted from the file · 334 pages · 879,939 characters

Text of RSR-032 Attachment 118_Part1.pdf

Extracted from the file · 164 pages · 353,286 characters

Text of RSR-032 Attachment 117.pdf

Extracted from the file · 55 pages · 49,861 characters

Text of RSR-032 Attachment 116.pdf

Extracted from the file · 2 pages · 5,651 characters

Text of RSR-032 Attachment 115.pdf

Extracted from the file · 135 pages · 191,165 characters

Text of RSR-032 Attachment 114.pdf

Extracted from the file · 123 pages · 185,862 characters

Text of RSR-032 Attachment 113.pdf

Extracted from the file · 4 pages · 596 characters

Text of RSR-032 Attachment 112.pdf

Extracted from the file · 2 pages · 298 characters

Text of RSR-032 Attachment 111.pdf

Extracted from the file · 42 pages · 123,247 characters

Text of RSR-032 Attachment 110.pdf

Extracted from the file · 38 pages · 8,159 characters

Text of RSR-032 Attachment 109.pdf

Extracted from the file · 1 page · 149 characters

Text of RSR-032 Attachment 108.pdf

Extracted from the file · 23 pages · 27,882 characters

Text of RSR-032 Attachment 107.pdf

Extracted from the file · 1 page · 243 characters

Text of RSR-032 Attachment 106.pdf

Extracted from the file · 1 page · 321 characters

Text of RSR-032 Attachment 105.pdf

Extracted from the file · 493 pages · 1,262,208 characters

Text of RSR-032 Attachment 104.pdf

Extracted from the file · 628 pages · 1,570,354 characters

Text of RSR-032 Attachment 103.pdf

Extracted from the file · 40 pages · 129,345 characters

Text of RSR-032 Attachment 102.pdf

Extracted from the file · 2 pages · 298 characters

Text of RSR-032 Attachment 101.pdf

Extracted from the file · 186 pages · 437,630 characters

Text of RSR-032 Attachment 100.pdf

Extracted from the file · 244 pages · 509,938 characters

Text of RSR-032 Attachment 99.pdf

Extracted from the file · 193 pages · 412,257 characters

Text of RSR-032 Attachment 98.pdf

Extracted from the file · 2,201 pages · 3,529,384 characters

Text of RSR-032 Attachment 97.pdf

Extracted from the file · 2 pages · 2,870 characters

Text of RSR-032 Attachment 96.pdf

Extracted from the file · 2 pages · 296 characters

Text of RSR-032 Attachment 95.pdf

Extracted from the file · 27 pages · 8,963 characters

Text of RSR-032 Attachment 94.pdf

Extracted from the file · 3 pages · 5,367 characters

Text of RSR-032 Attachment 93.pdf

Extracted from the file · 3 pages · 5,315 characters

Text of RSR-032 Attachment 92.pdf

Extracted from the file · 3 pages · 5,225 characters

Text of RSR-032 Attachment 91.pdf

Extracted from the file · 2 pages · 2,709 characters

Text of RSR-032 Attachment 90.pdf

Extracted from the file · 2 pages · 2,630 characters

Text of RSR-032 Attachment 89.pdf

Extracted from the file · 2 pages · 2,615 characters

Text of RSR-032 Attachment 88.pdf

Extracted from the file · 2 pages · 2,771 characters

Text of RSR-032 Attachment 87.pdf

Extracted from the file · 2 pages · 2,948 characters

Text of RSR-032 Attachment 86.pdf

Extracted from the file · 2 pages · 2,772 characters

Text of RSR-032 Attachment 85.pdf

Extracted from the file · 2 pages · 2,764 characters

Text of RSR-032 Attachment 84.pdf

Extracted from the file · 2 pages · 2,999 characters

Text of RSR-032 Attachment 83.pdf

Extracted from the file · 2 pages · 2,995 characters

Text of RSR-032 Attachment 82.pdf

Extracted from the file · 2 pages · 2,968 characters

Text of RSR-032 Attachment 81.pdf

Extracted from the file · 2 pages · 2,973 characters

Text of RSR-032 Attachment 80.pdf

Extracted from the file · 2 pages · 296 characters

Text of RSR-032 Attachment 79.pdf

Extracted from the file · 2 pages · 2,694 characters

Text of RSR-032 Attachment 78.pdf

Extracted from the file · 3 pages · 3,876 characters

Text of RSR-032 Attachment 77.pdf

Extracted from the file · 3 pages · 3,646 characters

Text of RSR-032 Attachment 76.pdf

Extracted from the file · 3 pages · 3,805 characters

Text of RSR-032 Attachment 75.pdf

Extracted from the file · 9 pages · 13,840 characters

Text of RSR-032 Attachment 74.pdf

Extracted from the file · 3 pages · 3,990 characters

Text of RSR-032 Attachment 73.pdf

Extracted from the file · 3 pages · 4,170 characters

Text of RSR-032 Attachment 72.pdf

Extracted from the file · 3 pages · 3,957 characters

Text of RSR-032 Attachment 71.pdf

Extracted from the file · 3 pages · 3,642 characters

Text of RSR-032 Attachment 70.pdf

Extracted from the file · 2 pages · 2,078 characters

Text of RSR-032 Attachment 69.pdf

Extracted from the file · 3 pages · 4,357 characters

Text of RSR-032 Attachment 68.pdf

Extracted from the file · 3 pages · 3,165 characters

Text of RSR-032 Attachment 67.pdf

Extracted from the file · 4 pages · 3,715 characters

Text of RSR-032 Attachment 66.pdf

Extracted from the file · 3 pages · 3,168 characters

Text of RSR-032 Attachment 65.pdf

Extracted from the file · 3 pages · 444 characters

Text of RSR-032 Attachment 64.pdf

Extracted from the file · 2 pages · 2,099 characters

Text of RSR-032 Attachment 63.pdf

Extracted from the file · 2 pages · 2,062 characters

Text of RSR-032 Attachment 62.pdf

Extracted from the file · 7 pages · 5,200 characters

Text of RSR-032 Attachment 61.pdf

Extracted from the file · 5 pages · 10,643 characters

Text of RSR-032 Attachment 60.pdf

Extracted from the file · 2 pages · 296 characters

Text of RSR-032 Attachment 59.pdf

Extracted from the file · 2 pages · 4,147 characters

Text of RSR-032 Attachment 58.pdf

Extracted from the file · 1 page · 2,448 characters

Text of RSR-032 Attachment 57.pdf

Extracted from the file · 2 pages · 296 characters

Text of RSR-032 Attachment 56.pdf

Extracted from the file · 10 pages · 1,491 characters

Text of RSR-032 Attachment 55_Part10.pdf

Extracted from the file · 286 pages · 344,076 characters

Text of RSR-032 Attachment 55_Part9.pdf

Extracted from the file · 500 pages · 957,292 characters

Text of RSR-032 Attachment 55_Part8.pdf

Extracted from the file · 500 pages · 874,750 characters

Text of RSR-032 Attachment 55_Part7.pdf

Extracted from the file · 500 pages · 470,022 characters

Text of RSR-032 Attachment 55_Part6.pdf

Extracted from the file · 500 pages · 494,317 characters

Text of RSR-032 Attachment 55_Part5.pdf

Extracted from the file · 500 pages · 461,760 characters

Text of RSR-032 Attachment 55_Part4.pdf

Extracted from the file · 500 pages · 492,694 characters

Text of RSR-032 Attachment 55_Part3.pdf

Extracted from the file · 500 pages · 580,603 characters

Text of RSR-032 Attachment 55_Part2.pdf

Extracted from the file · 500 pages · 483,371 characters

Text of RSR-032 Attachment 55_Part1.pdf

Extracted from the file · 500 pages · 881,595 characters

Text of RSR-032 Attachment 54.pdf

Extracted from the file · 121 pages · 447,477 characters

Text of RSR-032 Attachment 53.pdf

Extracted from the file · 204 pages · 625,248 characters

Text of RSR-032 Attachment 52.pdf

Extracted from the file · 130 pages · 298,641 characters

Text of RSR-032 Attachment 51.pdf

Extracted from the file · 57 pages · 123,610 characters

Text of RSR-032 Attachment 50.pdf

Extracted from the file · 6 pages · 8,050 characters

Text of RSR-032 Attachment 49.pdf

Extracted from the file · 83 pages · 194,182 characters

Text of RSR-032 Attachment 48.pdf

Extracted from the file · 3 pages · 8,556 characters

Text of RSR-032 Attachment 47.pdf

Extracted from the file · 10 pages · 14,266 characters

Text of RSR-032 Attachment 46.pdf

Extracted from the file · 7 pages · 10,783 characters

Text of RSR-032 Attachment 45.pdf

Extracted from the file · 373 pages · 490,688 characters

Text of RSR-032 Attachment 44.pdf

Extracted from the file · 38 pages · 6,799 characters

Text of RSR-032 Attachment 43.pdf

Extracted from the file · 49 pages · 83,514 characters

Text of RSR-032 Attachment 42.pdf

Extracted from the file · 25 pages, 14 without text · 13,836 characters

Text of RSR-032 Attachment 41.pdf

Extracted from the file · 3 pages · 5,506 characters

Text of RSR-032 Attachment 40.pdf

Extracted from the file · 1 page · 1,448 characters

Text of RSR-032 Attachment 39.pdf

Extracted from the file · 14 pages · 17,145 characters

Text of RSR-032 Attachment 38.pdf

Extracted from the file · 12 pages · 14,555 characters

Text of RSR-032 Attachment 37.pdf

Extracted from the file · 12 pages · 14,398 characters

Text of RSR-032 Attachment 36.pdf

Extracted from the file · 12 pages · 15,426 characters

Text of RSR-032 Attachment 35.pdf

Extracted from the file · 38 pages · 61,388 characters

Text of RSR-032 Attachment 34.pdf

Extracted from the file · 13 pages · 12,161 characters

Text of RSR-032 Attachment 33.pdf

Extracted from the file · 11 pages · 7,928 characters

Text of RSR-032 Attachment 32.pdf

Extracted from the file · 3 pages · 444 characters

Text of RSR-032 Attachment 31.pdf

Extracted from the file · 26 pages · 3,891 characters

Text of RSR-032 Attachment 30.pdf

Extracted from the file · 18 pages · 2,691 characters

Text of RSR-032 Attachment 29.pdf

Extracted from the file · 9 pages · 10,238 characters

Text of RSR-032 Attachment 28.pdf

Extracted from the file · 127 pages · 218,825 characters

Text of RSR-032 Attachment 27.pdf

Extracted from the file · 12 pages · 12,858 characters

Text of RSR-032 Attachment 26.pdf

Extracted from the file · 12 pages · 14,742 characters

Text of RSR-032 Attachment 25.pdf

Extracted from the file · 14 pages · 16,968 characters

Text of RSR-032 Attachment 24.pdf

Extracted from the file · 13 pages · 16,061 characters

Text of RSR-032 Attachment 23.pdf

Extracted from the file · 19 pages · 8,357 characters

Text of RSR-032 Attachment 22.pdf

Extracted from the file · 1,282 pages · 3,304,505 characters

Text of RSR-032 Attachment 21.pdf

Extracted from the file · 1,005 pages · 2,609,640 characters

Text of RSR-032 Attachment 20_Part2.pdf

Extracted from the file · 109 pages · 16,568 characters

Text of RSR-032 Attachment 20_Part1.pdf

Extracted from the file · 150 pages · 190,904 characters

Text of RSR-032 Attachment 19.pdf

Extracted from the file · 23 pages · 39,103 characters

Text of RSR-032 Attachment 18.pdf

Extracted from the file · 8 pages · 12,671 characters

Text of RSR-032 Attachment 17_Part3.pdf

Extracted from the file · 282 pages · 740,441 characters

Text of RSR-032 Attachment 17_Part2.pdf

Extracted from the file · 500 pages · 1,293,274 characters

Text of RSR-032 Attachment 17_Part1.pdf

Extracted from the file · 500 pages · 1,270,790 characters

Text of RSR-032 Attachment 16.pdf

Extracted from the file · 46 pages · 130,280 characters

Text of RSR-032 Attachment 15.pdf

Extracted from the file · 17 pages · 25,967 characters

Text of RSR-032 Attachment 14.pdf

Extracted from the file · 10 pages · 15,944 characters

Text of RSR-032 Attachment 13.pdf

Extracted from the file · 17 pages · 29,849 characters

Text of RSR-032 Attachment 12.pdf

Extracted from the file · 12 pages · 20,731 characters

Text of RSR-032 Attachment 11.pdf

Extracted from the file · 15 pages · 23,899 characters

Text of RSR-032 Attachment 10.pdf

Extracted from the file · 145 pages · 332,684 characters

Text of RSR-032 Attachment 9.pdf

Extracted from the file · 897 pages · 1,943,866 characters

Text of RSR-032 Attachment 8.pdf

Extracted from the file · 203 pages · 512,054 characters

Text of RSR-032 Attachment 7.pdf

Extracted from the file · 12 pages · 13,977 characters

Text of RSR-032 Attachment 6.pdf

Extracted from the file · 335 pages · 685,056 characters

Text of RSR-032 Attachment 5.pdf

Extracted from the file · 65 pages · 194,221 characters

Text of RSR-032 Attachment 4.pdf

Extracted from the file · 570 pages · 1,357,502 characters

Text of RSR-032 Attachment 3.pdf

Extracted from the file · 8 pages · 15,762 characters

Text of RSR-032 Attachment 2.pdf

Extracted from the file · 26 pages · 3,865 characters

Text of RSR-032 Attachment 1.pdf

Extracted from the file · 18 pages · 2,673 characters

As listed on the current system

Question(s) Answered 32 (Connecticut Light and Power Company dba Eversource Energy) Date Filed: 10/30/2026

This filing on the current system (opens in a new tab)