Skip to main content

A prototype public docket site for the Connecticut Public Utilities Regulatory Authority

Utility Dockets and Filings

Interrogatory responses

Answers to questions 32

ResponseFiled by Connecticut Light and Power Company dba Eversource Energy210 files
Part of docket 26-05-10Open
  • Electric
Application of The Connecticut Light and Power Company d/b/a Eversource Energy to Amend its Rate Schedules

Files210

Search terms highlighted
Eversource rate increase is on 9 pages across 3 files of the text below, highlighted. Go to the first matchClear highlighting
Words on different pages
Words on different pages
Words on different pages

Text of RSR-032 Attachment 176_Part2.pdf

Extracted from the file · 754 pages · 1,598,897 characters

Words on different pages
  1. Page 11 of 110

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-032 Attachment 176 Page 11 of 864 2.4 2022 Well Receptor Survey Stantec Consulting Services Inc. (Stantec) completed a Well Receptor Survey in 2022 to determine if any potential receptors, including public and private drinking water supply wells are located within a 500-foot radius of the Site. The survey was completed in accordance with the CTDEEP Water Supply Well Receptor Survey Guidance Document (September 2009, revised January 2015). In part, Stantec concluded the following: • • • • 3.0 Water supply wells or sensitive receptors were not identified within 500 feet of the Site. One property on Adams Road, southwest of the Site, is zoned residential but appeared vacant. Developed properties within the 500-foot radius are currently connected to the Metropolitan District Commission (MDC) public water distribution system. No wetlands are mapped at the Site or within 500 feet of the Site. ZUVIC noted that wetlands associated with Culbro Lake are present north of Blue Hills Avenue Extension, northeast, and within 500 ft., of the Site. Wetlands are also located on one property on Adams Road, southwest, and within 500 ft. of the Site. BACKGROUND AND PREVIOUS INVESTIGATIONS Historically, the Site was used for agricultural purposes (cultivation of tobacco), presumed drying of tobacco in two barns, storage of chemicals used for agricultural purposes in a third barn, and residential dwellings. The Site was developed with the current site building in 2001 and occupied by a fiber optic component manufacturer (JDS Uniphase (JDS)) until 2004 when Eversource occupied the building for use as office space for a call/data center. JDS was a small quantity generator (SQG) of hazardous waste (greater than 100 kilograms per month and less than 1,000 kilograms per month), including ignitable waste, corrosive acids, corrosive bases, and spent solvents. Due to hazardous waste generation rates by JDS, the property qualifies as an “establishment,” and when it was purchased by Eversource, was subject to the Connecticut Transfer Act (Section 22a-134 through 22a-134e of the Connecticut General Statutes). The property was transferred on December 1, 2021 to The Rocky River Realty Company (Eversource) and was entered into the CT PTP with submission of a Form III and ECAF to the CTDEEP on December 9, 2021. CTDEEP acknowledged receipt of the documentation on March 21, 2022. Eversource is the Certifying Party to the transfer, and as such, is responsible for investigation and remediation of the Site. CTDEEP assigned REM ID No. 14862 to the Site. The following investigations and CT PTP documentation for the Site have been completed and are presented in the following reports. Copies of the reports have been previously submitted to CTDEEP except for the Supplemental Investigation Report which is included in Appendix A. • • • • Phase I Environmental Site Assessment (ESA), 1985 Blue Hills Avenue Extension, Windsor, CT prepared by Stantec, dated July 13, 2021 Phase II ESA, 1985 Blue Hills Avenue Extension, Windsor, CT prepared by Stantec, dated July 28, 2021 2022 Well Receptor Survey, 1985 Blue Hills Avenue Extension, Windsor, CT (REM ID# 14862) prepared by Stantec, dated June 6, 2022 Environmental Condition Assessment Form (ECAF), dated December 9, 2021; Form III Transfer of Establishment Form (Form III), dated December 9, 2021; and Schedule Letter prepared by a Stantec Licensed Environmental Professional (LEP), dated May 24, 2022 Remedial Action Plan Eversource Call/Data Center, 1985 Blue Hills Ave Ext., Windsor, CT Page 3 of 24 H:\Projects\23246 - Eversource Blue Hills Ave Windsor Phase III\Reports\Enviro\RAP - Exterior\23246-13 RAP Text - 1985 Blue Hills Ave Windsor CT -Text FINAL -Rev1-20-25.docx
  2. Page 12 of 110

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-032 Attachment 176 Page 12 of 864 • • • • CTDEEP Form III Receipt Acknowledgement Letter, dated March 21, 2022 Phase II/III ESA, 1985 Blue Hills Avenue Extension, Windsor, CT prepared by ZUVIC, dated March 2024 Completion of Investigation, 1985 Blue Hills Avenue Extension, Windsor, CT prepared by ZUVIC, dated March 21, 2024 Supplemental Investigation Report, 1985 Blue Hills Avenue Extension, Windsor, CT prepared by ZUVIC, dated November 2024. The following Areas of Concern (AOCs) and Recognized Environmental Conditions (RECs) were identified and investigated during previous investigations listed above. The approximate location of each AOC and/or REC is shown on Figure 3. • • • • • • • • • • • • • REC 1 – Diesel Fuel Release at the Loading Docks REC 2 – Coolant Release from Emergency Generator REC 3 – Historical Barn/Warehouse Fire REC 4 – Release from Snow Removal Equipment AOC 1 – Loading Dock Area, Storm Drain, and Southeast Stormwater Detention Basin AOC 2 – Agricultural Use AOC 3 – Exterior Oil-Filled Electrical Transformers AOC 4 – Suspected Dumping Area AOC 5 – Former JDS Uniphase Site Operations AOC 6 – Two Emergency Diesel ASTs Associated with Emergency Generators (REC 2) AOC 7 – Former 7,000-Gallon Heating Oil UST at Barn/Office (REC 3) AOC 8 – Former Barns in the Central and the Southeastern Portions of the Site AOC 9 – Potential Off-Site Sources Based on results of previous investigations, release areas warranting remediation were identified at the following AOCs/RECs, at and near the noted borings for contaminants which exceed remedial criteria (Figures 3 and 6). • • • • • • REC 3 - Barn/Warehouse – extractable total petroleum hydrocarbons (ETPH), polynuclear aromatic hydrocarbons (PAHs), total and leachable arsenic and leachable lead in soil near B26, B27 and B29 from ground surface to approximately 8.5 fbg. Contaminants exceeding remedial criteria may be present within the entire barn foundation. REC 3 – West of Barn/Warehouse – leachable lead in soil near B44, from ground surface to approximately 4 fbg. REC 3 – Northeast of former Barn/Warehouse - pesticides in soil near B24/MW6 and B55, from ground surface to approximately 2 fbg and PAHs in soil near B56, from ground surface to at least 6 fbg AOC 4 – Dumping area – PAHs in soil near B21 and B61 and pesticides, leachable lead and/or leachable pesticides in soil near B23/MW7, B62 and B64, from ground surface to approximately 2 fbg. AOC 6 - Emergency generator AST southwest of the building - ETPH in soil near B10, from ground surface to approximately 1 fbg. AOC 8 – Southeastern former tobacco barn - pesticides in soil near B20, from ground surface to approximately 2 fbg and PAHs in soil near B61, from ground surface to 2 fbg. Pesticide concentrations detected in soil samples collected throughout the Site are generally consistent with application of pesticides and not indicative of point-sources with the exception of soil at and near B20 (southeastern barn, AOC 8), B23/MW7 and B64 (dumping area, AOC 4), and B24/MW6 and B55 (northeast of former Barn/Warehouse, REC 3) where remediation is warranted. Note that a RAP will be prepared if required for any remediation that may be warranted associated with former JDS operations (AOC 5) inside the Site building following completion of additional investigation work. Remedial Action Plan Eversource Call/Data Center, 1985 Blue Hills Ave Ext., Windsor, CT Page 4 of 24 H:\Projects\23246 - Eversource Blue Hills Ave Windsor Phase III\Reports\Enviro\RAP - Exterior\23246-13 RAP Text - 1985 Blue Hills Ave Windsor CT -Text FINAL -Rev1-20-25.docx
  3. Page 13 of 110

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-032 Attachment 176 Page 13 of 864 4.0 CURRENT ENVIRONMENTAL STATUS The following sections include a discussion of soil, groundwater and soil vapor conditions at each AOC/REC and corresponding conceptual site model (CSM). Summaries of soil, groundwater and soil vapor laboratory analytical data are presented in Tables 2A, 3 and 4, respectively. The boring locations are shown on Figure 3 and monitoring well locations are shown on Figure 4. The CSM and a summary of the RECs and AOCs are presented in Table 5. Given the GA classification of groundwater beneath the Site, the RDEC, I/C DEC and GA PMC for soil were compared to soil analytical data. Groundwater analytical data were compared to the GWPC, SWPC, RVC and I/C VC for groundwater. Soil vapor analytical results were compared to the residential soil vapor volatilization criteria (Res SVVC) and industrial/commercial soil vapor volatilization criteria (I/C SVVC). If default Connecticut RSR criteria have not been established for detected compounds, RDEC, I/C DEC, GA PMC, SWPC, RVC, I/C VC, Res SVVC, and I/C SVVS contained in the CTDEEP “Technical Support Document: Recommended Numeric Criteria for Common Additional Polluting Substances and Certain Alternative Criteria Requests,” dated September 20, 2018 or from the CTDEEP form entitled "Request for Approval of Criteria for Additional Polluting Substances," dated March 25, 2022 were used for comparison purposes. CTDEEP approval is required for use of these criteria, is commonly granted and will be sought prior to remediation. 4.1 Soil and Groundwater 4.1.1 Soil Remediation Standards For soil, the CTDEEP has adopted two types of remediation standards, one to address direct exposure (e.g., through ingestion of, or dermal contact with, contaminated soil) and a second to address pollutant mobility (i.e., the potential for leachate from contaminated soil to impact groundwater quality above a particular threshold). Direct exposure criteria (DEC) have been developed for two types of land use scenarios, as follows: (i) residential land use; and (ii) industrial/commercial land use. The industrial/commercial direct exposure criteria would currently apply to the Site given its past and current industrial/commercial use. However, such an application would require placement of an environmental use restriction (EUR) to ensure that the parcel or restricted portion(s) of the parcel are not used for any residential purpose in the future, and that its use be limited to industrial or commercial activities. Since an EUR has not been recorded, the Residential Direct Exposure Criteria (RDEC) would currently apply to this Site. Groundwater beneath the Site is classified by the CTDEEP as “GA”, therefore, the pollutant mobility criteria (PMC) for soil in GA areas would be applicable. For both DEC and PMC, the CTDEEP has adopted numeric standards that serve as “default” criteria unless acceptable site-specific or alternate criteria are developed, or unless background concentrations or analytical detection limits in soil exceed these numeric standards. In addition, there are a few circumstances where conditional exemptions or variances from the DEC and PMC are allowed. Where applicable, based on existing data, these exemptions, variances, site-specific or alternate criteria will be discussed. In general, site-specific or alternate criteria are not developed unless there are exceedances of the more protective default criteria. According to the RSRs, the DEC are compared to soil quality data from total mass analyses, and apply to soil within 15 feet (ft.) of the ground surface unless the soil is inaccessible in accordance with RSR Section 22a133k-2(b)(3). In a GA area, the PMC apply to soil from ground surface to the seasonal low water table, estimated at between approximately 11 and 17 feet deep. For pollutant mobility for metals or polychlorinated biphenyls (PCBs), one Remedial Action Plan Eversource Call/Data Center, 1985 Blue Hills Ave Ext., Windsor, CT Page 5 of 24 H:\Projects\23246 - Eversource Blue Hills Ave Windsor Phase III\Reports\Enviro\RAP - Exterior\23246-13 RAP Text - 1985 Blue Hills Ave Windsor CT -Text FINAL -Rev1-20-25.docx
  4. Page 14 of 110

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-032 Attachment 176 Page 14 of 864 can either compare predicted or actual leaching data for a given metal or PCB to its GA PMC. For other constituents, one can compare leaching data to the GWPC multiplied by the appropriate dilution/attenuation factor if appropriate, or one can compare total mass analysis data to the PMC. 4.1.2 Groundwater Remediation Standards In “GA” classified areas such as this site, there are four types of groundwater remediation standards which apply under the RSRs: (i) the groundwater protection criteria (GWPC); (ii) the surface-water protection criteria (SWPC); (iii) background concentrations; and (iv) the volatilization criteria (VC) for any groundwater polluted with VOCs within a certain depth below the ground surface or a building. The GWPC are designed to ensure that the quality of existing and potential drinking water supplies is not impacted. The SWPC are designed to ensure that contaminant concentrations in groundwater do not adversely impact water quality in a surface water body receiving groundwater discharges, except as follows. For a wetland or intermittent stream, the RSRs assume there may be no dilution and therefore the aquatic life criteria (AQLC) (contained in the Water Quality Standards) are used as the SWPC (i.e., are compared directly to the contaminant concentrations in the groundwater plume(s)). The AQLC are not applicable to the Site since groundwater does not discharge to wetlands or an intermittent stream. The SWPC can be compared to plume concentrations immediately upgradient of the point of discharge to the surface water body or to the 95% upper confidence limit of the arithmetic mean of samples representative of the subject groundwater plume. Groundwater in a GA area is required to meet background concentrations unless the conditions described below are met, then compliance with the GWPC is permitted. • Concentrations in groundwater are below the GWPC. • One of the following conditions is met: o Public water is available within 200 ft. of the site, within 200 ft. of all abutting properties, and within 200 ft. of all properties within the aerial extent of the plume; the plume is not located in an aquifer protection area; and the plume is not located within the area of influence of any public water supply well. o The plume is a diminishing state groundwater plume prior to any remediation. o Reduction of concentrations in groundwater to background concentrations cannot be achieved using sound engineering and hydrogeologic remediation practices. Provided concentrations in groundwater are compliant with the GWPC, compliance with background concentrations is not required since public water is available within 200 ft. of the Site, within 200 ft. of all abutting properties, and within 200 ft. of all properties within the aerial extent of the plume. In addition, any plumes at the Site are not located in an aquifer protection area and are not located within the area of influence of any public water supply well. The volatilization criteria (VC) apply to groundwater polluted with VOCs within a certain depth beneath the ground surface or a structure depending on the type of VOC present. The VC apply to groundwater within 10 feet of the ground surface or lowest portion of a building if it is polluted with petroleum substances and 30 feet for VOCs other than petroleum substances. There are both residential and industrial/commercial default VC; residential VC apply to properties except those used solely for industrial or commercial activity, provided an EUR is in effect which ensures that the parcel will not be used for any residential purpose in the future, and that any future use of the parcel is limited to industrial or commercial activity. Since an EUR has not been recorded for the Site, the Residential VC (RVC) would currently apply to the Site. Remedial Action Plan Eversource Call/Data Center, 1985 Blue Hills Ave Ext., Windsor, CT Page 6 of 24 H:\Projects\23246 - Eversource Blue Hills Ave Windsor Phase III\Reports\Enviro\RAP - Exterior\23246-13 RAP Text - 1985 Blue Hills Ave Windsor CT -Text FINAL -Rev1-20-25.docx
  5. Page 15 of 110

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-032 Attachment 176 Page 15 of 864 There are VC that apply to concentrations in groundwater (GWVC) and those that apply to concentrations in soil vapor (SVVC). Compliance with the VC can be demonstrated using either contaminant concentrations in groundwater compared to the GWVC or using contaminant concentrations in soil vapor compared to the SVVC. 4.1.3 REC 1 – Diesel Fuel Release at Loading Dock REC 2 - Coolant Release from Emergency Generator AOC 1- Loading Dock Area, Storm Drain, and Southeast Stormwater Detention Basin AOC 6 – Two Emergency Diesel ASTs These four RECs/AOCs are presented together due to their proximity, common contaminants of concern (COCs) and release mechanisms. A diesel fuel release occurred at the loading docks in May 2011. Diesel fuel was released to paved surfaces and a nearby catch basin and conveyed to a stormwater detention basin located southeast of the building. According to records, the release was contained, and “hard” surfaces cleaned of residual fuel. Two backup emergency generators are present at the Site, one in the parking lot southwest of the building and one adjacent to the south wall of the building and west of the loading dock area; each generator is equipped with a diesel storage tank. June 2017 records indicate that a hose on one of the generators failed leading to a release of approximately 40-gallons of coolant inside the generator enclosure. Approximately 5-gallons of coolant seeped through seams of the enclosure onto a concrete pad and gravel near the enclosure. JDS presumably received, shipped and managed chemicals and hazardous materials, including wastes, at the loading docks. In addition, hydraulic oil associated with two hydraulic compactors, and potential temporary storage of oil or chemicals in the dumpsters may have resulted in releases in the area. Soil samples collected from borings L1985-1, -2, -3MW, -4, -7, -13, and -15 and from B6 through B11, B17, B18, B32, B40, B41 and B58 were used to evaluate these RECs and AOCs. COCs identified for the RECs and AOCs include volatile organic compounds (VOCs), ETPH, SVOCs or PAHs; ethylene glycol (EG) and propylene glycol (PG) (REC 2 only); and 1,4-dioxane, per- and polyfluoroalkyl substances (PFAS) and RCRA 8 metals plus copper, nickel, and zinc and alcohols (AOC 1 only). 1,4-Dioxane and PFAS are COCs for AOC 1 since former manufacturing of fiber optic components may have used or generated wastes containing these emerging contaminants. VOCs, glycols and alcohols were not detected in soil samples. The results of metals testing applicable to AOC 1 are discussed in Section 4.1.6 (AOC 2 and AOC 8). Releases associated with the coolant release were not evident and additional investigation and remediation are not warranted. Low-level ETPH contamination is present in surficial soil near the loading docks, at L1985-1 and in deeper soil (10-11 fbg) at L1985-3MW; PAHs were not detected. The concentrations in these samples were all below remedial criteria. The surficial contamination near the loading docks is likely related to incidental releases from the normal operation of motor vehicles. The deeper contamination in L1985-3MW is likely related to crosscontamination from surficial soils mixing with deeper soils during drilling. Additional evaluation and remediation are not warranted near these borings. Low-level ETPH and PAH contamination was detected in surficial soil at L1985-15, near the stormwater outlet pipe in the southern stormwater detention basin; concentrations are below remedial criteria. Surficial soil samples collected from B17 and B18 contained PAHs below criteria. The release of diesel fuel to the catch Remedial Action Plan Eversource Call/Data Center, 1985 Blue Hills Ave Ext., Windsor, CT Page 7 of 24 H:\Projects\23246 - Eversource Blue Hills Ave Windsor Phase III\Reports\Enviro\RAP - Exterior\23246-13 RAP Text - 1985 Blue Hills Ave Windsor CT -Text FINAL -Rev1-20-25.docx
  6. Page 16 of 110

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-032 Attachment 176 Page 16 of 864 basin in the loading dock area apparently resulted in residual contamination below remedial criteria in the stormwater basin. Alternatively, the PAH detections may be due to temporary storage of stormwater in the basin that contains PAHs leached from asphalt parking areas. Additional evaluation and remediation are not warranted near these borings. Low levels of PAHs or ETPH were detected in surficial soil collected from L1985-7 (near the emergency generator/AST southwest of the building), and L1985-13, B9, and B32 (near the emergency generator west of the loading docks). The contamination may be due to placement of contaminated fill during installation of the generator enclosures. Additional evaluation and remediation are not warranted near these borings. Surficial soil samples collected from borings near the generator southwest of the building (B10 and B11) did not contain detectable PAHs, however ETPH was detected in sample B10 0.3-1 fbg above the RDEC and GA PMC potentially related to a release during refueling of the generator. Leachable ETPH was not detected in the sample, demonstrating compliance with the PMC. The ETPH release at B10 was delineated vertically by sample B10 1-3 fbg and laterally by samples B40 0.3-1 fbg and B41 0.3-1 fbg, in which ETPH was not detected. The ETPH release is limited to the shallow soils in the vicinity of B10 and remediation is warranted. COCs were not detected in groundwater associated with AOC 1 and REC 1. The release of diesel fuel at REC 2 extended to 1 foot deep, approximately 10 feet above the water table, and potential impacts to groundwater associated with the release are not expected. 4.1.4 REC 3 - Historical Barn/Warehouse and Fire AOC 7 - Former 7,000-gallon Heating Oil Underground Storage Tank (UST) REC 3 and AOC 7 are presented together since the former barn/warehouse, associated outdoor storage area and the former fuel oil UST were located in proximity to one another on the southern portion of the Site. The former barn/warehouse was destroyed in May 1994 by a structure fire that was extinguished using water. The structure was used for storing pesticides, herbicides, and other chemicals, and as office space in its eastern portion. Following the fire, samples of air, surface wipes, water runoff from firefighting, and surficial soil were analyzed for pesticides. Low levels of pesticides were detected in one water runoff sample. An approximately 6,750-gallon heating oil UST was reportedly located north of the northeastern corner of the barn/warehouse. In addition, aerial photographs indicate that an outdoor storage area was present near the northwestern corner of the barn. Soil samples collected from borings L1985-8, -9, and -10MW and B26, B27, B27A, B28, B29 and B44 through B54 were used to evaluate soil within, or near the footprint of the barn. Soil samples collected from borings B30, B31, B42 and B43 were used to evaluate soil within the outdoor storage area, and B24/MW6, B24A, B25, B55, B56 and B57 were used to evaluate soil near the UST. COCs for REC 3 and AOC 7 include VOCs, ETPH, SVOCs or PAHs, pesticides, herbicides, and RCRA 8 metals plus copper, nickel, and zinc (REC 3 only). Fill materials, including non-native red-brown soil and/or non-soil materials (asphalt, coal, brick, concrete, glass, and ash) was encountered from ground surface to approximately 8.5 fbg in borings L1985-8, L1985-10, B27, B29, B45, B48, B49, B51 and B56. A presumed basement concrete floor associated with the former barn/warehouse building was encountered in borings L1987-8, L1985-10, B26, B27, B27A, B29, B45, B47, B48 and B51 at various depths between approximately 6 and 10 fbg. The shallower depths of concrete may be remnants of foundation walls that were pushed into the basement after the fire. Based on material encountered in B24/MW6, B25, B55, B56 and B57, these borings are located outside the former barn footprint. B29, B49 and B51 are within an “entrance/exit” structure on the north side of the barn, Remedial Action Plan Eversource Call/Data Center, 1985 Blue Hills Ave Ext., Windsor, CT Page 8 of 24 H:\Projects\23246 - Eversource Blue Hills Ave Windsor Phase III\Reports\Enviro\RAP - Exterior\23246-13 RAP Text - 1985 Blue Hills Ave Windsor CT -Text FINAL -Rev1-20-25.docx
  7. Page 17 of 110

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-032 Attachment 176 Page 17 of 864 apparent in aerial photographs. B50 appears to be located outside the northwest corner of the “entrance/exit”. B28 and B44 are located west of the barn footprint and L1985-9, B53 and B54 are apparently located within the office area that was constructed between 1935 and 1941 at the eastern end of the building which may have been a slab-on-grade addition, without a basement. It appears that at least a portion of the demolished structure and imported fill material were placed inside the footprint of the barn to backfill the basement and may have also been spread and placed northeast of the structure in the vicinity of B56. The VOC, acetone was detected in soil samples L1985-10MW 1-3 ft. and B47 2-4 fbg at concentrations below RSR criteria. The apparent acetone contamination may be related to laboratory-induced contamination. The SVOC, isophorone was detected in soil sample B26 8-10 fbg at a concentration below RSR criteria. This sample was collected just below the apparent concrete floor of the basement and the isophorone is likely a result of a chemical reaction between concrete in the sample and acetone used by the laboratory and not related to a release. Herbicides were not detected in soil samples. Low-level VOC (naphthalene, xylenes and/or MEK) contamination was detected in samples B27 2-4 fbg, B27A 2-4 fbg and B47 2-4 fbg at concentrations below RSR criteria. The contamination may be due to the presence of demolished building materials, potentially containing materials that were stored in the basement prior to the fire. Low-level ETPH and/or PAH contamination were detected in surficial soil near L1985-9, L1985-10MW, B24/MW6, B45, B55, B57 and in deeper soil at B26 8-10 fbg, B27A 2-4 fbg, B28 6-8 fbg, B29 6-8.5 fbg, B44 2-4 fbg, B45 4-6 fbg, B46 2-4 fbg, B47 2-4 fbg, B48 4-5 fbg, B52 4-6 fbg and B54 6-8 fbg, at concentrations below RSR criteria. Soil collected from B26 5-7.5 fbg and B27 2-4 fbg contain ETPH and SVOCs, respectively, at concentrations above the RDEC, I/C DEC and/or GA PMC. Leachable SVOCs/PAHs in the B27 sample and leachable ETPH in the B26 sample were below the GWPC, demonstrating compliance with the PMC. The ETPH release at B26 was delineated vertically by sample B26 8-10 fbg in which ETPH was not detected and laterally by B52 4-6 fbg, B53 6-8 fbg and B54 6-8 fbg. The SVOC release at B27 was delineated vertically by samples B27A 4-6 fbg and B27 6-7.5 fbg and laterally by B47 2-4 fbg, B48 2-4, B48 4-5 fbg and B52 4-6 fbg, in which SVOCs/PAHs were either not detected or detected below RSR criteria. Remediation is required near B26 and B27 and the releases are sufficiently delineated vertically and laterally to proceed with remediation. PAHs were also detected above the RDEC, I/C DEC and/or GA PMC in soil samples outside the northeast corner of the presumed barn/warehouse footprint from B56 2-4 fbg and B56 4-6 fbg. Leachable PAHs in the 2 to 4 fbg sample were below the GWPC, demonstrating compliance with the PMC. The 4-6 fbg sample was not tested for leachable PAHs, however concentrations of PAHs in the sample were below or similar in concentrations to PAHs detected in B27 2-4 fbg, therefore soil from B56 4-6 fbg is likely compliant with the PMC. PAH contaminants encountered in B56 may be attributed to the presence of demolished/burned building materials containing ash and brick or imported backfill that was used to backfill the footprint of the former barn/warehouse and likely spread out in the vicinity of B56 prior to the area being paved. The release at B56 was partially delineated laterally by samples B24A 2-4 fbg, B25 2-4 fbg and B55 0-2 fbg. Remediation is required near B56, and the release is sufficiently delineated laterally in most directions. Additional evaluation to delineate the vertical and lateral extent of contamination in this area may be desired prior to remediation. Pesticides, and in some cases, elevated metals (arsenic, barium, cadmium, chromium, lead and/or nickel), were detected in soil in and near the footprint of the barn in surficial soil at B24/MW6, B50, B53, B55 and B57 and in deeper soil at B24A 2-4 and 4-6 fbg, B27 2-4 fbg, B28 6-8 and 16-18 fbg, B29 6-8.5 fbg, B44 2-4 and 16-18 fbg, B47 8-9.5 fbg and B56 2-4 fbg; concentrations in most cases exceed the GA PMC. Leachable pesticides in the samples tested were below the GWPC, including those with some of the highest concentrations of total pesticides, demonstrating compliance with the PMC. Remedial Action Plan Eversource Call/Data Center, 1985 Blue Hills Ave Ext., Windsor, CT Page 9 of 24 H:\Projects\23246 - Eversource Blue Hills Ave Windsor Phase III\Reports\Enviro\RAP - Exterior\23246-13 RAP Text - 1985 Blue Hills Ave Windsor CT -Text FINAL -Rev1-20-25.docx
  8. Page 18 of 110

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-032 Attachment 176 Page 18 of 864 The chlordane concentration in samples B24/MW6 0-2 fbg and B55 0-2 fbg (near the northeast corner of the barn) are above the RDEC. The pesticide releases at B24/MW6 and B55 were delineated vertically by samples B24A 2-4 fbg and B25 2-4 fbg and laterally by samples B57 0-2 fbg and B56 2-4 fbg. Remediation is required near B24/MW6 and B55 and the pesticide contamination is sufficiently delineated vertically and laterally in most directions to proceed with remediation. Total metals were either not detected or reported at concentrations within the ranges of naturally-occurring levels present in uncontaminated soil except for elevated concentrations of arsenic, barium, cadmium, chromium, lead, mercury, nickel and/or zinc in L1985-9, L1985-10MW, B26, B48 and B51. Where tested, these samples did not contain detectable pesticides. Leachable metals in the tested samples are compliant with the GA PMC except as described below. Total arsenic in sample B29 6-8.5 fbg exceeds the RDEC and I/C DEC and leachable arsenic and lead exceed the GA PMC. The metals exceedances in B29 were delineated vertically by soil sample B29 9-11 fbg and laterally by soil samples B50 6-8 fbg, B51 6-7.5 fbg, B49 4-6 fbg and B49 6-8 fbg. Remediation is required near the boring and the contamination is sufficiently delineated vertically and laterally to proceed with remediation. The leachable lead concentration in soil sample B44 2-4 fbg exceeds the GA PMC. The exceedance is delineated vertically by B44 4-6 fbg and partially delineated laterally by B28 6-8 fbg. Additional evaluation to delineate the lateral extent of contamination in this area may be desired prior to remediation. The ETPH, VOC, PAH, pesticide and metals contaminants co-occur in backfill material that is within the footprint of the barn. The contamination is attributed to the presence of demolished building materials including ash, and may also contain materials that were stored in the basement prior to the fire. The contaminated material requiring remediation is likely irregular and may occur throughout the entire barn footprint. COCs were not detected in groundwater samples collected in May 2021, September 2023 and May 2024 from L1985-10MW located within the barn/warehouse footprint. Evidence of a surficial pesticide release in the vicinity of the outdoor storage area near the northwest corner of the barn was identified based on surficial soil samples tested from B31, B42 and B43. Surficial samples collected from B31, B42 and B43 that contained total pesticides above the GA PMC were tested for leachable pesticides with the results below the GWPC, demonstrating compliance with the PMC. The pesticide release to surficial soil by B31, B42 and B43 has been sufficiently delineated and no further evaluation is warranted. In addition, a deeper soil sample collected from 12 to 14 fbg at B42 contained total pesticides below applicable criteria. The contamination in the deeper sample may be due to releases near B31, B42 and B43 or from a release associated with an unknown source or off-site source located upgradient of the former outdoor storage area. Samples collected at B28 6 to 8 fbg and below the water table at B28 16 to18 fbg and B44 16-18 fbg, located outside of the barn foundation and downgradient of the release area at B31, B42 and B43, contained total pesticides in some cases, above the GA PMC. Leachable pesticides in the samples were below the GWPC, demonstrating compliance with the PMC. The contamination at B28 and B44 may be related to pesticide storage at or near the two borings if the outdoor storage area encompassed the area immediately west of the building. The contamination in samples collected below the water table may be due to releases in the storage area or to an unknown source or off-site source located upgradient of these borings that resulted in down gradient, soil-adsorbed contamination below the water table. Based on the current data, remediation is not required, however additional investigations are warranted. Remedial Action Plan Eversource Call/Data Center, 1985 Blue Hills Ave Ext., Windsor, CT Page 10 of 24 H:\Projects\23246 - Eversource Blue Hills Ave Windsor Phase III\Reports\Enviro\RAP - Exterior\23246-13 RAP Text - 1985 Blue Hills Ave Windsor CT -Text FINAL -Rev1-20-25.docx
  9. Page 19 of 110

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-032 Attachment 176 Page 19 of 864 Based on conditions observed in six borings completed in the reported area of the UST, the UST is no longer present and was apparently removed from the ground. Evidence of a release in the vicinity of the UST was not observed based on surficial and deeper samples analyzed from B24/MW6, B24A, B25, B55, B56 and B57. In addition, groundwater collected from B24/MW6 did not contain detectable levels of ETPH, VOCs or PAHs. Lowlevel PAH detections in surficial soil at B24/MW6, B55 and B57 are likely related to runoff from adjacent paved surfaces containing PAHs leached from asphalt pavement. Sufficient investigation associated with the UST has been completed and remediation is not required. 4.1.5 REC 4 - Release from Snow Removal Equipment Snow removal equipment is at times stored in the eastern end of the northern parking lot. During a site visit, Stantec observed oily staining on pavement in this area. One stain appeared wet from a recent equipment leak and was observed intersecting a crack in the pavement. Boring L1985-5MW, B12, B13 and B14 were used to evaluate the REC. COCs for REC 4 include VOCs, ETPH, and PAHs. A constituent of petroleum products, m,p-xylene, was detected below remedial criteria in a surficial soil collected from L1985-5MW; VOCs were not detected in surficial samples from B12, B13, and B14. Low-level ETPH and/or PAH contamination was detected in surficial soil at B12 and B13 at concentrations below remedial criteria. The release of fuel associated with snow removal equipment storage in this area apparently resulted in residual contamination below remedial criteria. The nature, extent and degree of VOC, ETPH and PAH contamination at this REC have been evaluated and all concentrations are below the RDEC and GA PMC, therefore additional evaluation or remediation is not warranted. COCs were not detected in groundwater collected in May 2021, September 2023 and May 2024 from L19855MW with the exception of ETPH in groundwater collected in May 2021. Although not a COC, nickel was detected in groundwater collected in May 2024. ETPH and nickel concentrations were below applicable criteria and groundwater collected in May 2021 was turbid which may have resulted in the apparent ETPH contamination due to soil-adsorbed contaminants in the sample. Samples collected in September 2023 and May 2024 from these wells were not turbid and ETPH was not detected. The nickel contamination may represent a transient condition, since the metal was detected on only one occasion. Additional groundwater monitoring will be required to evaluate compliance. 4.1.6 AOC 2 - Agricultural Use AOC 8 - Former Barns in the Central and Southeastern Portions of the Site The western and central portions of the Site were used for tobacco cultivation from before 1943 through the 1990s. In addition, three barns were located at the Site, one of which was located near the southern property line and reportedly used for chemical storage (see REC 3). The other barns are assumed to have been used for tobacco drying and were located in the southern portion of the stormwater detention basin and near the central portion of the current building. Borings L1985-3MW, L1985-6MW, L1985-7, and L1985-15, B1/MW1, B2/MW2, B3/MW3, B4/MW4, B5/MW5, B6 through B9, B11, B12, B17 through B20, B20A, B32, B33, B59, B60 and B61 were used to evaluate the AOCs. Borings L1985-3MW, B3/MW3, B4/MW4 and B5/MW5 are downgradient of the former barn located in the central portion of the current building and B19, B20, B20A, B59, B60 and B61 are specific to the southeastern barn. The remainder of the samples are applicable to AOC 2. Samples used to characterize the Remedial Action Plan Eversource Call/Data Center, 1985 Blue Hills Ave Ext., Windsor, CT Page 11 of 24 H:\Projects\23246 - Eversource Blue Hills Ave Windsor Phase III\Reports\Enviro\RAP - Exterior\23246-13 RAP Text - 1985 Blue Hills Ave Windsor CT -Text FINAL -Rev1-20-25.docx
  10. Page 20 of 110

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-032 Attachment 176 Page 20 of 864 area near the southern barn (REC 3) and the suspected dumping area (AOC 4) are discussed in Sections 4.1.4 and 4.1.8, respectively. COCs identified for AOCs 2 and 8 include VOCs, ETPH, SVOCs or PAHs (AOC 8); and, pesticides, herbicides and RCRA 8 metals plus copper, nickel, and zinc (AOCs 2 and 8). Pesticides (primarily DDD, DDE, DDT, dieldrin and/or chlordane) were detected above the GA PMC in surficial soil from borings L1985-7, L1985-15, B2/MW2, B3/MW3, B4/MW4, B5/MW5, B9, B11, B12, B17, B18, B19, B20, B33, B59, B60 and B61 and in 2-4 foot-interval samples from B60 and B61. Lower levels of pesticides, below criteria, were detected in other surficial and deeper samples. Samples containing the highest concentrations of pesticides were tested for leachable pesticides which were not detected or were below the GWPC, demonstrating compliance with the GA PMC. Chlordane was detected at AOC 8 in B20 0-2 fbg at a concentration above the RDEC and below the I/C DEC. The release is delineated vertically by sample B20A 2-4 fbg and laterally by samples B59 0-2 fbg, B60 0-2 fbg and B61 0-2 fbg. Remediation is warranted to attain compliance with the RDEC. Total metals were either not detected or reported at concentrations within the ranges of naturally-occurring levels present in uncontaminated soil except for elevated concentrations of specific metals at the following AOC 2 borings: L1985-7 (nickel), B17 (copper, nickel and zinc) and B18 (copper, lead and zinc). Total and leachable metals concentrations at these locations are compliant with the RDEC and GA PMC. Herbicides were not detected in samples applicable to AOCs 2 and 8. In some cases, pesticides and elevated metals co-occur in surficial soil throughout the Site. The concentrations are consistent with historical application of pesticides. Sufficient investigation has been completed associated with AOC 2 and remediation is not required. ETPH and VOCs were not detected in samples collected at AOC 8. Total metals were either not detected or reported at concentrations within the ranges of naturally-occurring levels present in uncontaminated soil. Low-level PAH contamination (below criteria) is present in surficial soil at B1/MW1 and as described in Section 4.1.9, may be due to placement of contaminated backfill during construction of the building or to leaching of PAHs from asphalt pavement. Remediation or additional evaluation of the contamination is not warranted. One of more PAHs were detected in B20 0-2 fbg, B59 0-2 fbg, B60 0-2 fbg and B61 0-2 and 2-4 fbg. The concentrations in B61 0-2 fbg are above the RDEC. The contamination does not appear to be due to storage of chemicals inside the former barn since the same PAHs, with similar ratios, were detected in samples collected in the northwestern portion of the stormwater detention basin, approximately 200 ft. from the former barn location, and in the suspected dumping area (AOC 4), approximately 150 ft. west of the former barn. The PAHs in all three locations are likely related to impacts from stormwater containing PAHs leached from asphalt parking areas and the roadway. COCs were not detected in groundwater collected from wells B1/MW1, B2/MW2, B3/MW3, B4/MW4, B5/MW5 L1985-3MW and L1985-6MW in May 2021, September 2023 and/or May 2024 with the exception of the following: • Pesticides (dieldrin, heptachlor epoxide) and chromium were detected in the sample collected from L1985-3MW in May 2024 with dieldrin above the GWPC. • SVOCs (benzyl alcohol, 2-methyl phenol and 3+4 methyl phenol) were detected in the sample collected from L1985-3MW in September 2023 below applicable criteria. Remedial Action Plan Eversource Call/Data Center, 1985 Blue Hills Ave Ext., Windsor, CT Page 12 of 24 H:\Projects\23246 - Eversource Blue Hills Ave Windsor Phase III\Reports\Enviro\RAP - Exterior\23246-13 RAP Text - 1985 Blue Hills Ave Windsor CT -Text FINAL -Rev1-20-25.docx

Text of RSR-032 Attachment 175_Part7.pdf

Extracted from the file · 275 pages · 622,526 characters

Text of RSR-032 Attachment 175_Part6.pdf

Extracted from the file · 350 pages · 828,421 characters

Text of RSR-032 Attachment 175_Part5.pdf

Extracted from the file · 350 pages · 841,526 characters

Text of RSR-032 Attachment 175_Part4.pdf

Extracted from the file · 350 pages · 529,828 characters

Text of RSR-032 Attachment 175_Part3.pdf

Extracted from the file · 350 pages · 417,827 characters

Text of RSR-032 Attachment 175_Part2.pdf

Extracted from the file · 350 pages · 717,402 characters

Text of RSR-032 Attachment 175_Part1.pdf

Extracted from the file · 350 pages · 426,888 characters

Text of RSR-032 Attachment 174.pdf

Extracted from the file · 2 pages · 3,788 characters

Text of RSR-032 Attachment 173.pdf

Extracted from the file · 9 pages · 19,276 characters

Text of RSR-032 Attachment 172.pdf

Extracted from the file · 2 pages · 5,216 characters

Text of RSR-032 Attachment 171.pdf

Extracted from the file · 2 pages · 7,025 characters

Text of RSR-032 Attachment 170.pdf

Extracted from the file · 4 pages · 596 characters

Text of RSR-032 Attachment 169.pdf

Extracted from the file · 14 pages · 2,105 characters

Text of RSR-032 Attachment 168.pdf

Extracted from the file · 178 pages · 303,260 characters

Text of RSR-032 Attachment 167_Part2.pdf

Extracted from the file · 844 pages · 1,367,165 characters

Text of RSR-032 Attachment 167_Part1.pdf

Extracted from the file · 284 pages · 480,797 characters

Text of RSR-032 Attachment 166.pdf

Extracted from the file · 4 pages · 5,984 characters

Text of RSR-032 Attachment 165_Part 4.pdf

Extracted from the file · 84 pages · 130,960 characters

Text of RSR-032 Attachment 165_Part 3.pdf

Extracted from the file · 482 pages · 674,897 characters

Text of RSR-032 Attachment 165_Part 2.pdf

Extracted from the file · 509 pages · 549,394 characters

Text of RSR-032 Attachment 165_Part 1.pdf

Extracted from the file · 500 pages · 578,799 characters

Text of RSR-032 Attachment 164.pdf

Extracted from the file · 42 pages, 16 without text · 66,266 characters

Text of RSR-032 Attachment 163.pdf

Extracted from the file · 575 pages · 624,136 characters

Text of RSR-032 Attachment 162.pdf

Extracted from the file · 17 pages · 19,879 characters

Text of RSR-032 Attachment 161 _Part2.pdf

Extracted from the file · 609 pages · 625,572 characters

Text of RSR-032 Attachment 161 _Part1.pdf

Extracted from the file · 131 pages · 171,359 characters

Text of RSR-032 Attachment 160.pdf

Extracted from the file · 56 pages · 84,793 characters

Text of RSR-032 Attachment 159.pdf

Extracted from the file · 97 pages · 159,126 characters

Text of RSR-032 Attachment 158.pdf

Extracted from the file · 54 pages · 96,528 characters

Text of RSR-032 Attachment 157.pdf

Extracted from the file · 261 pages · 326,004 characters

Text of RSR-032 Attachment 156.pdf

Extracted from the file · 74 pages · 99,158 characters

Text of RSR-032 Attachment 155.pdf

Extracted from the file · 40 pages · 40,141 characters

Text of RSR-032 Attachment 154.pdf

Extracted from the file · 37 pages · 59,275 characters

Text of RSR-032 Attachment 153.pdf

Extracted from the file · 61 pages · 86,468 characters

Text of RSR-032 Attachment 152.pdf

Extracted from the file · 126 pages · 258,689 characters

Text of RSR-032 Attachment 151.pdf

Extracted from the file · 340 pages · 405,994 characters

Text of RSR-032 Attachment 150.pdf

Extracted from the file · 33 pages · 27,344 characters

Text of RSR-032 Attachment 149.pdf

Extracted from the file · 47 pages · 51,678 characters

Text of RSR-032 Attachment 148.pdf

Extracted from the file · 52 pages · 65,933 characters

Text of RSR-032 Attachment 147.pdf

Extracted from the file · 136 pages · 187,807 characters

Text of RSR-032 Attachment 146.pdf

Extracted from the file · 211 pages · 257,714 characters

Text of RSR-032 Attachment 145.pdf

Extracted from the file · 58 pages · 84,698 characters

Text of RSR-032 Attachment 144.pdf

Extracted from the file · 31 pages · 57,751 characters

Text of RSR-032 Attachment 143.pdf

Extracted from the file · 30 pages · 51,258 characters

Text of RSR-032 Attachment 142.pdf

Extracted from the file · 33 pages · 29,732 characters

Text of RSR-032 Attachment 141.pdf

Extracted from the file · 578 pages · 899,265 characters

Text of RSR-032 Attachment 140.pdf

Extracted from the file · 26 pages · 45,518 characters

Text of RSR-032 Attachment 139.pdf

Extracted from the file · 29 pages · 58,671 characters

Text of RSR-032 Attachment 138.pdf

Extracted from the file · 24 pages · 44,766 characters

Text of RSR-032 Attachment 137.pdf

Extracted from the file · 54 pages · 85,922 characters

Text of RSR-032 Attachment 136.pdf

Extracted from the file · 618 pages · 1,036,591 characters

Text of RSR-032 Attachment 135.pdf

Extracted from the file · 52 pages · 107,952 characters

Text of RSR-032 Attachment 134.pdf

Extracted from the file · 57 pages · 119,843 characters

Text of RSR-032 Attachment 133.pdf

Extracted from the file · 82 pages · 196,725 characters

Text of RSR-032 Attachment 132.pdf

Extracted from the file · 137 pages · 251,594 characters

Text of RSR-032 Attachment 131.pdf

Extracted from the file · 7 pages · 1,043 characters

Text of RSR-032 Attachment 130.pdf

Extracted from the file · 847 pages · 1,478,588 characters

Text of RSR-032 Attachment 129.pdf

Extracted from the file · 124 pages · 255,121 characters

Text of RSR-032 Attachment 128.pdf

Extracted from the file · 104 pages · 208,223 characters

Text of RSR-032 Attachment 127.pdf

Extracted from the file · 125 pages · 243,340 characters

Text of RSR-032 Attachment 126.pdf

Extracted from the file · 128 pages · 264,919 characters

Text of RSR-032 Attachment 125.pdf

Extracted from the file · 824 pages · 1,180,085 characters

Text of RSR-032 Attachment 124.pdf

Extracted from the file · 28 pages · 47,835 characters

Text of RSR-032 Attachment 123.pdf

Extracted from the file · 29 pages · 4,370 characters

Text of RSR-032 Attachment 122.pdf

Extracted from the file · 29 pages · 4,370 characters

Text of RSR-032 Attachment 121.pdf

Extracted from the file · 50 pages · 7,541 characters

Text of RSR-032 Attachment 120.PDF

Extracted from the file · 2 pages · 3,192 characters

Text of RSR-032 Attachment 119_Part3.pdf

Extracted from the file · 105 pages · 238,387 characters

Text of RSR-032 Attachment 119_Part2.pdf

Extracted from the file · 169 pages · 372,755 characters

Text of RSR-032 Attachment 119_Part1.pdf

Extracted from the file · 51 pages · 61,331 characters

Text of RSR-032 Attachment 118_Part6.pdf

Extracted from the file · 54 pages · 47,246 characters

Text of RSR-032 Attachment 118_Part5.pdf

Extracted from the file · 254 pages · 39,246 characters

Text of RSR-032 Attachment 118_Part4.pdf

Extracted from the file · 378 pages · 97,273 characters

Text of RSR-032 Attachment 118_Part3.pdf

Extracted from the file · 218 pages · 519,182 characters

Text of RSR-032 Attachment 118_Part2.pdf

Extracted from the file · 334 pages · 879,939 characters

Text of RSR-032 Attachment 118_Part1.pdf

Extracted from the file · 164 pages · 353,286 characters

Text of RSR-032 Attachment 117.pdf

Extracted from the file · 55 pages · 49,861 characters

Text of RSR-032 Attachment 116.pdf

Extracted from the file · 2 pages · 5,651 characters

Text of RSR-032 Attachment 115.pdf

Extracted from the file · 135 pages · 191,165 characters

Text of RSR-032 Attachment 114.pdf

Extracted from the file · 123 pages · 185,862 characters

Text of RSR-032 Attachment 113.pdf

Extracted from the file · 4 pages · 596 characters

Text of RSR-032 Attachment 112.pdf

Extracted from the file · 2 pages · 298 characters

Text of RSR-032 Attachment 111.pdf

Extracted from the file · 42 pages · 123,247 characters

Text of RSR-032 Attachment 110.pdf

Extracted from the file · 38 pages · 8,159 characters

Text of RSR-032 Attachment 109.pdf

Extracted from the file · 1 page · 149 characters

Text of RSR-032 Attachment 108.pdf

Extracted from the file · 23 pages · 27,882 characters

Text of RSR-032 Attachment 107.pdf

Extracted from the file · 1 page · 243 characters

Text of RSR-032 Attachment 106.pdf

Extracted from the file · 1 page · 321 characters

Text of RSR-032 Attachment 105.pdf

Extracted from the file · 493 pages · 1,262,208 characters

Text of RSR-032 Attachment 104.pdf

Extracted from the file · 628 pages · 1,570,354 characters

Text of RSR-032 Attachment 103.pdf

Extracted from the file · 40 pages · 129,345 characters

Text of RSR-032 Attachment 102.pdf

Extracted from the file · 2 pages · 298 characters

Text of RSR-032 Attachment 101.pdf

Extracted from the file · 186 pages · 437,630 characters

Text of RSR-032 Attachment 100.pdf

Extracted from the file · 244 pages · 509,938 characters

Text of RSR-032 Attachment 99.pdf

Extracted from the file · 193 pages · 412,257 characters

Text of RSR-032 Attachment 98.pdf

Extracted from the file · 2,201 pages · 3,529,384 characters

Text of RSR-032 Attachment 97.pdf

Extracted from the file · 2 pages · 2,870 characters

Text of RSR-032 Attachment 96.pdf

Extracted from the file · 2 pages · 296 characters

Text of RSR-032 Attachment 95.pdf

Extracted from the file · 27 pages · 8,963 characters

Text of RSR-032 Attachment 94.pdf

Extracted from the file · 3 pages · 5,367 characters

Text of RSR-032 Attachment 93.pdf

Extracted from the file · 3 pages · 5,315 characters

Text of RSR-032 Attachment 92.pdf

Extracted from the file · 3 pages · 5,225 characters

Text of RSR-032 Attachment 91.pdf

Extracted from the file · 2 pages · 2,709 characters

Text of RSR-032 Attachment 90.pdf

Extracted from the file · 2 pages · 2,630 characters

Text of RSR-032 Attachment 89.pdf

Extracted from the file · 2 pages · 2,615 characters

Text of RSR-032 Attachment 88.pdf

Extracted from the file · 2 pages · 2,771 characters

Text of RSR-032 Attachment 87.pdf

Extracted from the file · 2 pages · 2,948 characters

Text of RSR-032 Attachment 86.pdf

Extracted from the file · 2 pages · 2,772 characters

Text of RSR-032 Attachment 85.pdf

Extracted from the file · 2 pages · 2,764 characters

Text of RSR-032 Attachment 84.pdf

Extracted from the file · 2 pages · 2,999 characters

Text of RSR-032 Attachment 83.pdf

Extracted from the file · 2 pages · 2,995 characters

Text of RSR-032 Attachment 82.pdf

Extracted from the file · 2 pages · 2,968 characters

Text of RSR-032 Attachment 81.pdf

Extracted from the file · 2 pages · 2,973 characters

Text of RSR-032 Attachment 80.pdf

Extracted from the file · 2 pages · 296 characters

Text of RSR-032 Attachment 79.pdf

Extracted from the file · 2 pages · 2,694 characters

Text of RSR-032 Attachment 78.pdf

Extracted from the file · 3 pages · 3,876 characters

Text of RSR-032 Attachment 77.pdf

Extracted from the file · 3 pages · 3,646 characters

Text of RSR-032 Attachment 76.pdf

Extracted from the file · 3 pages · 3,805 characters

Text of RSR-032 Attachment 75.pdf

Extracted from the file · 9 pages · 13,840 characters

Text of RSR-032 Attachment 74.pdf

Extracted from the file · 3 pages · 3,990 characters

Text of RSR-032 Attachment 73.pdf

Extracted from the file · 3 pages · 4,170 characters

Text of RSR-032 Attachment 72.pdf

Extracted from the file · 3 pages · 3,957 characters

Text of RSR-032 Attachment 71.pdf

Extracted from the file · 3 pages · 3,642 characters

Text of RSR-032 Attachment 70.pdf

Extracted from the file · 2 pages · 2,078 characters

Text of RSR-032 Attachment 69.pdf

Extracted from the file · 3 pages · 4,357 characters

Text of RSR-032 Attachment 68.pdf

Extracted from the file · 3 pages · 3,165 characters

Text of RSR-032 Attachment 67.pdf

Extracted from the file · 4 pages · 3,715 characters

Text of RSR-032 Attachment 66.pdf

Extracted from the file · 3 pages · 3,168 characters

Text of RSR-032 Attachment 65.pdf

Extracted from the file · 3 pages · 444 characters

Text of RSR-032 Attachment 64.pdf

Extracted from the file · 2 pages · 2,099 characters

Text of RSR-032 Attachment 63.pdf

Extracted from the file · 2 pages · 2,062 characters

Text of RSR-032 Attachment 62.pdf

Extracted from the file · 7 pages · 5,200 characters

Text of RSR-032 Attachment 61.pdf

Extracted from the file · 5 pages · 10,643 characters

Text of RSR-032 Attachment 60.pdf

Extracted from the file · 2 pages · 296 characters

Text of RSR-032 Attachment 59.pdf

Extracted from the file · 2 pages · 4,147 characters

Text of RSR-032 Attachment 58.pdf

Extracted from the file · 1 page · 2,448 characters

Text of RSR-032 Attachment 57.pdf

Extracted from the file · 2 pages · 296 characters

Text of RSR-032 Attachment 56.pdf

Extracted from the file · 10 pages · 1,491 characters

Text of RSR-032 Attachment 55_Part10.pdf

Extracted from the file · 286 pages · 344,076 characters

Text of RSR-032 Attachment 55_Part9.pdf

Extracted from the file · 500 pages · 957,292 characters

Text of RSR-032 Attachment 55_Part8.pdf

Extracted from the file · 500 pages · 874,750 characters

Text of RSR-032 Attachment 55_Part7.pdf

Extracted from the file · 500 pages · 470,022 characters

Text of RSR-032 Attachment 55_Part6.pdf

Extracted from the file · 500 pages · 494,317 characters

Text of RSR-032 Attachment 55_Part5.pdf

Extracted from the file · 500 pages · 461,760 characters

Text of RSR-032 Attachment 55_Part4.pdf

Extracted from the file · 500 pages · 492,694 characters

Text of RSR-032 Attachment 55_Part3.pdf

Extracted from the file · 500 pages · 580,603 characters

Text of RSR-032 Attachment 55_Part2.pdf

Extracted from the file · 500 pages · 483,371 characters

Text of RSR-032 Attachment 55_Part1.pdf

Extracted from the file · 500 pages · 881,595 characters

Text of RSR-032 Attachment 54.pdf

Extracted from the file · 121 pages · 447,477 characters

Text of RSR-032 Attachment 53.pdf

Extracted from the file · 204 pages · 625,248 characters

Text of RSR-032 Attachment 52.pdf

Extracted from the file · 130 pages · 298,641 characters

Text of RSR-032 Attachment 51.pdf

Extracted from the file · 57 pages · 123,610 characters

Text of RSR-032 Attachment 50.pdf

Extracted from the file · 6 pages · 8,050 characters

Text of RSR-032 Attachment 49.pdf

Extracted from the file · 83 pages · 194,182 characters

Text of RSR-032 Attachment 48.pdf

Extracted from the file · 3 pages · 8,556 characters

Text of RSR-032 Attachment 47.pdf

Extracted from the file · 10 pages · 14,266 characters

Text of RSR-032 Attachment 46.pdf

Extracted from the file · 7 pages · 10,783 characters

Text of RSR-032 Attachment 45.pdf

Extracted from the file · 373 pages · 490,688 characters

Text of RSR-032 Attachment 44.pdf

Extracted from the file · 38 pages · 6,799 characters

Text of RSR-032 Attachment 43.pdf

Extracted from the file · 49 pages · 83,514 characters

Text of RSR-032 Attachment 42.pdf

Extracted from the file · 25 pages, 14 without text · 13,836 characters

Text of RSR-032 Attachment 41.pdf

Extracted from the file · 3 pages · 5,506 characters

Text of RSR-032 Attachment 40.pdf

Extracted from the file · 1 page · 1,448 characters

Text of RSR-032 Attachment 39.pdf

Extracted from the file · 14 pages · 17,145 characters

Text of RSR-032 Attachment 38.pdf

Extracted from the file · 12 pages · 14,555 characters

Text of RSR-032 Attachment 37.pdf

Extracted from the file · 12 pages · 14,398 characters

Text of RSR-032 Attachment 36.pdf

Extracted from the file · 12 pages · 15,426 characters

Text of RSR-032 Attachment 35.pdf

Extracted from the file · 38 pages · 61,388 characters

Text of RSR-032 Attachment 34.pdf

Extracted from the file · 13 pages · 12,161 characters

Text of RSR-032 Attachment 33.pdf

Extracted from the file · 11 pages · 7,928 characters

Text of RSR-032 Attachment 32.pdf

Extracted from the file · 3 pages · 444 characters

Text of RSR-032 Attachment 31.pdf

Extracted from the file · 26 pages · 3,891 characters

Text of RSR-032 Attachment 30.pdf

Extracted from the file · 18 pages · 2,691 characters

Text of RSR-032 Attachment 29.pdf

Extracted from the file · 9 pages · 10,238 characters

Text of RSR-032 Attachment 28.pdf

Extracted from the file · 127 pages · 218,825 characters

Text of RSR-032 Attachment 27.pdf

Extracted from the file · 12 pages · 12,858 characters

Text of RSR-032 Attachment 26.pdf

Extracted from the file · 12 pages · 14,742 characters

Text of RSR-032 Attachment 25.pdf

Extracted from the file · 14 pages · 16,968 characters

Text of RSR-032 Attachment 24.pdf

Extracted from the file · 13 pages · 16,061 characters

Text of RSR-032 Attachment 23.pdf

Extracted from the file · 19 pages · 8,357 characters

Text of RSR-032 Attachment 22.pdf

Extracted from the file · 1,282 pages · 3,304,505 characters

Text of RSR-032 Attachment 21.pdf

Extracted from the file · 1,005 pages · 2,609,640 characters

Text of RSR-032 Attachment 20_Part2.pdf

Extracted from the file · 109 pages · 16,568 characters

Text of RSR-032 Attachment 20_Part1.pdf

Extracted from the file · 150 pages · 190,904 characters

Text of RSR-032 Attachment 19.pdf

Extracted from the file · 23 pages · 39,103 characters

Text of RSR-032 Attachment 18.pdf

Extracted from the file · 8 pages · 12,671 characters

Text of RSR-032 Attachment 17_Part3.pdf

Extracted from the file · 282 pages · 740,441 characters

Text of RSR-032 Attachment 17_Part2.pdf

Extracted from the file · 500 pages · 1,293,274 characters

Text of RSR-032 Attachment 17_Part1.pdf

Extracted from the file · 500 pages · 1,270,790 characters

Text of RSR-032 Attachment 16.pdf

Extracted from the file · 46 pages · 130,280 characters

Text of RSR-032 Attachment 15.pdf

Extracted from the file · 17 pages · 25,967 characters

Text of RSR-032 Attachment 14.pdf

Extracted from the file · 10 pages · 15,944 characters

Text of RSR-032 Attachment 13.pdf

Extracted from the file · 17 pages · 29,849 characters

Text of RSR-032 Attachment 12.pdf

Extracted from the file · 12 pages · 20,731 characters

Text of RSR-032 Attachment 11.pdf

Extracted from the file · 15 pages · 23,899 characters

Text of RSR-032 Attachment 10.pdf

Extracted from the file · 145 pages · 332,684 characters

Text of RSR-032 Attachment 9.pdf

Extracted from the file · 897 pages · 1,943,866 characters

Text of RSR-032 Attachment 8.pdf

Extracted from the file · 203 pages · 512,054 characters

Text of RSR-032 Attachment 7.pdf

Extracted from the file · 12 pages · 13,977 characters

Text of RSR-032 Attachment 6.pdf

Extracted from the file · 335 pages · 685,056 characters

Text of RSR-032 Attachment 5.pdf

Extracted from the file · 65 pages · 194,221 characters

Text of RSR-032 Attachment 4.pdf

Extracted from the file · 570 pages · 1,357,502 characters

Text of RSR-032 Attachment 3.pdf

Extracted from the file · 8 pages · 15,762 characters

Text of RSR-032 Attachment 2.pdf

Extracted from the file · 26 pages · 3,865 characters

Text of RSR-032 Attachment 1.pdf

Extracted from the file · 18 pages · 2,673 characters

As listed on the current system

Question(s) Answered 32 (Connecticut Light and Power Company dba Eversource Energy) Date Filed: 10/30/2026

This filing on the current system (opens in a new tab)