Skip to main content

A prototype public docket site for the Connecticut Public Utilities Regulatory Authority

Utility Dockets and Filings

Interrogatory responses

Answers to questions 32

ResponseFiled by Connecticut Light and Power Company dba Eversource Energy210 files
Part of docket 26-05-10Open
  • Electric
Application of The Connecticut Light and Power Company d/b/a Eversource Energy to Amend its Rate Schedules

Files210

Search terms highlighted
Eversource rate increase is on 9 pages across 3 files of the text below, highlighted. Go to the first matchClear highlighting
Words on different pages
Words on different pages
Words on different pages

Text of RSR-032 Attachment 176_Part2.pdf

Extracted from the file · 754 pages · 1,598,897 characters

Text of RSR-032 Attachment 176_Part1.pdf

Extracted from the file · 110 pages · 439,601 characters

Text of RSR-032 Attachment 175_Part7.pdf

Extracted from the file · 275 pages · 622,526 characters

Text of RSR-032 Attachment 175_Part6.pdf

Extracted from the file · 350 pages · 828,421 characters

Text of RSR-032 Attachment 175_Part5.pdf

Extracted from the file · 350 pages · 841,526 characters

Text of RSR-032 Attachment 175_Part4.pdf

Extracted from the file · 350 pages · 529,828 characters

Text of RSR-032 Attachment 175_Part3.pdf

Extracted from the file · 350 pages · 417,827 characters

Text of RSR-032 Attachment 175_Part2.pdf

Extracted from the file · 350 pages · 717,402 characters

Text of RSR-032 Attachment 175_Part1.pdf

Extracted from the file · 350 pages · 426,888 characters

Text of RSR-032 Attachment 174.pdf

Extracted from the file · 2 pages · 3,788 characters

Text of RSR-032 Attachment 173.pdf

Extracted from the file · 9 pages · 19,276 characters

Text of RSR-032 Attachment 172.pdf

Extracted from the file · 2 pages · 5,216 characters

Text of RSR-032 Attachment 171.pdf

Extracted from the file · 2 pages · 7,025 characters

Text of RSR-032 Attachment 170.pdf

Extracted from the file · 4 pages · 596 characters

Text of RSR-032 Attachment 169.pdf

Extracted from the file · 14 pages · 2,105 characters

Text of RSR-032 Attachment 168.pdf

Extracted from the file · 178 pages · 303,260 characters

Text of RSR-032 Attachment 167_Part2.pdf

Extracted from the file · 844 pages · 1,367,165 characters

Text of RSR-032 Attachment 167_Part1.pdf

Extracted from the file · 284 pages · 480,797 characters

Text of RSR-032 Attachment 166.pdf

Extracted from the file · 4 pages · 5,984 characters

Text of RSR-032 Attachment 165_Part 4.pdf

Extracted from the file · 84 pages · 130,960 characters

Words on different pages
  1. Page 396 of 482

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-032 Attachment 165 Page 1414 of 1638 Project: REMEDIATION OF PCB-IMPACTED STREA SEDIMENT ENVIANCE SPILL NUMBER CWC-18-00543 ABBREVIATIONS CONSTRUCTION NOTES: AC ACCMP ARV ASTM BC BIT BLDG BM BO BV CATV CB CC CI CL CL CMP CONC CU FT CY D DI DIA DMH DWG E EA EF ELEV EOP EW EX. FLG FT G GALV GC GR HC HORIZ HP HYD I OR INV ID IP LB LF LS MAX MB MDC MECH MH MIN MISC MJ N NE NW NF NO OR # OD PCCP PE PL PL PVC PVMT RCP ROW RT RQD S SE SECT SF SHT SPEC SPS SQ FT SS STA STL SW T TBM THK TYP UP VC VERT W W/ W/O 1. SURVEY PERFORMED BY KCI TECHNOLOGIES, INC. IN MARCH, 2023. ADDITIONAL SURVEY DATA COLLECTED BY WESTON & SAMPSON IN JUNE 2023. OTHER PLAN INFORMATION WAS GENERATED FROM PUBLICLY AVAILABLE GEOGRAPHIC INFORMATION SYSTEMS DATABASES. 2. THE CONTRACTOR SHALL "CALL BEFORE YOU DIG" (CBYD) AT [phone removed] OR 811 AT LEAST 48 HOURS, SATURDAYS, SUNDAYS, AND HOLIDAYS EXCLUDED, PRIOR TO EXCAVATING AT ANY LOCATION. A COPY OF THE CBYD PROJECT REFERENCE NUMBER(S) SHALL BE GIVEN TO OWNER PRIOR TO EXCAVATION. 3. LOCATIONS OF EXISTING PIPES, CONDUITS, UTILITIES, FOUNDATIONS AND OTHER UNDERGROUND OBJECTS ARE NOT WARRANTED TO BE CORRECT AND THE CONTRACTOR SHALL HAVE NO CLAIM ON THAT ACCOUNT SHOULD THEY BE OTHER THAN SHOWN. CONTRACTOR SHALL PERFORM TEST PITTING TO CONFIRM UNDERGROUND PIPE LOCATIONS AS DESCRIBED IN THE SPECIFICATION SECTION 01 14 00 - SPECIAL PROVISIONS. 4. CONTRACTOR SHALL VISIT AND EXAMINE THE SITE TO FULLY UNDERSTAND ALL THE CONDITIONS PERTAINING TO THE WORK, UNDERSTAND DIFFICULTIES TO BE ENCOUNTERED, UNDERSTAND THE SCOPE OF THE REMEDIATION AND CONCRETE REPLACEMENT WORK FOR ALL SYSTEMS WHETHER SHOWN OR DESCRIBED AT NO ADDITIONAL COST TO OWNER. CONTRACTOR TO VERIFY ALL DIMENSIONS, CLEARANCE ELEVATIONS, SITE FEATURES/ANCILLARY ITEMS, SERVICES, SIZES OF EXISTING UTILITY PIPES AND BUILDINGS THROUGHOUT THE SITE. 27 PARSONS LANE, DURHAM, CT LEGEND EXISTING PROPOSED SANITARY SEWER S S FORCE MAIN FM FM WATER MAIN W W GAS G G UNDERGROUND ELECTRIC UE UE UNDERGROUND TELEPHONE T T OVERHEAD WIRES OW OW SANITARY SEWER MANHOLE S SMH STORM DRAIN MANHOLE D SDMH DESCRIPTION ELECTRICAL MANHOLE EMH TELEPHONE MANHOLE TMH CLEANOUT CO CATCH BASIN CB Y WV H D HYDRANT CHECK VALVE S O CURB STOP W GATE VALVE BUTTERFLY VALVE BALL VALVE REDUCER CAP OR PLUG GAS GATE VALVE GV UTILITY POLE LIGHT POST EDGE OF PAVEMENT EDGE OF UNPAVED ROAD CURB SIDEWALK RAILROAD STONE WALL RETAINING WALL RET WALL RET WALL FENCE X X INDIVIDUAL DECIDUOUS TREE INDIVIDUAL EVERGREEN TREE TREE LINE SURVEY MARKER PROPERTY LINE P EASEMENT LINE LIMIT OF WORK SPOT ELEVATIONS x 141.5 x 141.5 CONTOUR LINES 56 56 DEPRESSION CONTOUR LINES WETLAND 1 WETLAND FLAGS 2 B B TEST PIT 1 TP-1 BORING B-10 B-11 PROBE P-10 P-11 BOLLARD SIGN BENCH MARK STRAW BALES / STRAW WATTLES ROCK OUTCROP DRAINAGE DITCH / SWALE TRANSFORMER T ANTI-TRACKING PAD EXISTING DRAIN LINE D ASBESTOS CEMENT PIPE ASPHALT COATED CORRUGATED METAL PIPE AIR RELEASE VALVE AMERICAN SOCIETY FOR TESTING AND MATERIALS BITUMINOUS CONCRETE BITUMINOUS BUILDING BENCH MARK BLOW OFF BUTTERFLY VALVE CABLE TELEVISION CATCH BASIN CONCRETE CURB CAST IRON CENTERLINE CEMENT LINED OR CENTERLINE CORRUGATED METAL PIPE CONCRETE CUBIC FEET CUBIC YARD STORM DRAIN, DEPTH FROM RIM TO INVERT DROP INLET, DUCTILE IRON DIAMETER DRAIN MANHOLE DRAWING EAST, ELECTRIC EACH EACH FACE ELEVATION EDGE OF PAVEMENT EACH WAY EXISTING FLANGE FEET, FOOT NATURAL GAS GALVANIZED GRANITE CURB GRANITE HOUSE CONNECTION HORIZONTAL HIGH PRESSURE FIRE HYDRANT INVERT INSIDE DIAMETER IRON PIPE POUND LINEAR FEET LUMP SUM MAXIMUM MAIL BOX METROPOLITAN DISTRICT COMMISSION MECHANICAL MANHOLE MINIMUM MISCELLANEOUS MECHANICAL JOINT NORTH NORTH EAST NORTH WEST NOT FOUND NUMBER OUTSIDE DIAMETER PRESTRESSED CONCRETE CYLINDER PIPE PLAIN END, POLYETHYLENE PROPERTY LINE PLATE POLYVINYL CHLORIDE PAVEMENT REINFORCED CONCRETE PIPE RIGHT-OF-WAY RADIO TOWER ROCK QUALITY SEWER, SOUTH, SILL ELEVATION SOUTH EAST SECTION SQUARE FEET SHEET SPECIFICATIONS SEWAGE PUMP STATION SQUARE FEET SEWER SERVICE, STAINLESS STEEL STATION STEEL SIDEWALK, SOUTH WEST HYDROSTATIC THRUST, TELEPHONE TEMPORARY BENCH MARK THICK (NESS) TYPICAL UTILITY POLE VITRIFIED CLAY VERTICAL WATER, WEST WITH WITHOUT 5. THE OWNER AND THE ENGINEER ARE NOT RESPONSIBLE FOR BIDDERS' OR CONTRACTOR'S HEALTH AND SAFETY DURING VISITS. THE BIDDERS AND CONTRACTOR SHALL BE RESPONSIBLE FOR THE HEALTH AND SAFETY OF THEIR EMPLOYEES AND ANY OF THEIR SUBCONTRACTORS. 6. EXCAVATION SHALL BE PERFORMED AS REQUIRED FOR TEST PITTING, UTILITY REPLACEMENT, IMPACTED SOIL REMOVAL SHOWN ON SHEET C002 AND SITE RESTORATION ACTIVITIES ONLY. THE CONTRACTOR SHALL BACKFILL EXCAVATED AREAS TO MATCH SURROUNDING STREAM GRADE TO PREVENT PONDING IN ACCORDANCE WITH SPECIFICATION SECTION 31 00 00-EARTHWORK AND SHEET C004 - SITE RESTORATION PLAN. 7. SOIL AND CONTAINERIZED WATER SHALL BE REMOVED AND DISPOSED OF AS DETAILED IN THE CONTRACT DOCUMENTS, UNLESS OTHERWISE INDICATED BY THE ENGINEER. 8. ALL SOLID WASTE AND REGULATED WASTE SHALL BE MANAGED IN ACCORDANCE WITH ALL APPLICABLE STATE AND FEDERAL REGULATIONS AND PER SECTIONS 02 61 0016 - HANDLING, REUSE, TRANSPORTATION, AND OFFSITE DISPOSAL OF EXCAVATED MATERIAL. 9. ALL WORK UNDER THIS CONTRACT SHALL BE LIMITED TO THE LIMIT OF WORK BOUNDARY SHOWN ON SHEET C002 AND C003. 10. ALL AREAS DISTURBED BY THE CONTRACTOR, INCLUDING INSTALLATION OF TEMPORARY FENCING AND PLACEMENT OF STRAW WATTLES, SHALL BE RESTORED BY THE CONTRACTOR AT NO ADDITIONAL COST TO OWNER. 11. THE CONTRACTOR SHALL CONDUCT ALL REMEDIATION ACTIVITY DURING DAYLIGHT HOURS BETWEEN 7:00 A.M. AND 5:00 P.M., MONDAY THROUGH FRIDAY. CONTRACTOR SHALL COORDINATE WITH OWNER TO SCHEDULE INTERIOR RESTORATION WORK. Weston & Sampson Engineers, Inc. 712 Brook Street, Suite 103 Rocky Hill, CT 06067 [phone removed] 800.SAMPSON www.westonandsampson.com Consultants: Revisions: No. 1 Date Description 10/8/2024 DRAINAGE LAYOUT, APPROACH 12. ALL PAVED AREAS, CURBING, AND SIDEWALKS DISTURBED BY THE CONTRACTOR BEYOND THE LIMITS OF WORK, INCLUDING PLACEMENT OF CATCH BASIN PROTECTION CONTROL AND SIGNAGE SHALL BE RESTORED BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER. 13. THE EXISTING STORMWATER COLLECTION SYSTEM SHALL REMAIN AND THE CONTRACTOR SHALL PROTECT CATCH BASINS, STORMWATER DRAINS, AND MANHOLES WITHIN THE LIMIT OF WORK PER DRAWINGS AND SPECIFICATION SECTION 01 57 19-ENVIRONMENTAL PROTECTION. 14. CONTRACTOR SHALL UTILIZE ONLY AREAS WITHIN THE LIMIT OF WORK FOR EMPLOYEE PARKING, VEHICLE AND EQUIPMENT STORAGE, AND TEMPORARY MATERIAL/DEBRIS STAGING AS SHOWN ON THE DRAWINGS AND PER SPECIFICATION SECTIONS 01 12 16-SCOPE AND SEQUENCE OF WORK, 01 11 00-CONTROL OF WORK AND MATERIALS, AND 01 14 00-SPECIAL PROVISIONS, UNLESS OTHERWISE APPROVED BY OWNER. Seal: 15. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SITE RELATED DUST CONTROL PER SPECIFICATION SECTION 01 14 19.16-DUST CONTROL. 16. ALL MATERIAL HAULING VEHICLES SHALL BE COMPLETELY COVERED PRIOR TO LEAVING THE SITE. 17. THE CONTRACTOR SHALL KEEP THE SITE ENTRANCES AND EXITS, AS SHOWN ON THE CONTRACT DRAWING, OPEN, ACCESSIBLE, AND FREE OF DEBRIS, MATERIALS, AND/OR EQUIPMENT AT ALL TIMES DURING THE PROJECT. ACCESS MUST BE AVAILABLE TO THE OWNER, POLICE, AND FIRE DEPARTMENTS AT ALL TIMES. 18. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL WHEEL CLEANING OF ALL CONSTRUCTION VEHICLES PRIOR TO ENTERING STREETS AND ROADWAYS. CONTRACTOR SHALL ENSURE THAT MATERIAL HAULING VEHICLES REMAIN ON PAVED SURFACES AS MUCH AS POSSIBLE. ALL MATERIAL GENERATED AS A RESULT OF WHEEL CLEANING SHALL BE DISPOSED OF PROPERLY IN ACCORDANCE WITH ALL APPLICABLE FEDERAL, STATE AND LOCAL REGULATIONS. 19. ALL SOLID WASTE AND HAZARDOUS WASTE SHALL BE MANAGED IN ACCORDANCE WITH ALL APPLICABLE LOCAL, STATE AND FEDERAL REGULATIONS. 20. MISCELLANEOUS DISCREPANCIES OR OMISSIONS THAT MAY NOT APPEAR ON THE PLANS OR SPECIFICATIONS WILL NOT RELIEVE THE CONTRACTOR FROM CODE COMPLIANCE. COA: COPYRIGHT © 2020 BY WESTON & SAMPSON, PE, LS, LA, PC THIS DRAWING IS AN INSTRUMENT OF SERVICE AND IS THE PROPERTY OF WESTON & SAMPSON, PE, LS, LA, PC THIS DRAWING MAY NOT BE REPRODUCED IN WHOLE OR IN PART BY ANY MEANS WHATSOEVER WITHOUT THE EXPRESS WRITTEN CONSENT OF WESTON & SAMPSON PE, LS, LA, PC UNAUTHORIZED ALTERATION OR ADDITION TO THIS DOCUMENT IS A VIOLATION OF SECTION 7209. SUBDIVISION 2 OF THE NEW YORK STATE EDUCATION LAW. Issued For: Scale: Date: JULY 2024 Drawn By: PRB Reviewed By: JW Approved By: PVU W&S Project No.: W&S File No.: ENG23-0443 Drawing Title: NOTE: ITEMS SHOWN IN THE LEGEND MAY NOT BE PRESENT IN THESE PLANS NOTES, LEGEND, & ABBREVIATIONS Sheet Number: G001
  2. Page 397 of 482

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-032 Attachment 165 Page 1415 of 1638 LEGEND: Project: NOTES 1. THIS SURVEY AND MAP HAS BEEN PREPARED IN ACCORDANCE WITH THE REGULATIONS OF CONNECTICUT STATE AGENCIES, SECTIONS 20-300b-1 THRU 20-300b-20. THE HORIZONTAL AND VERTICAL ACCURACY CONFORMS TO CLASS A-2 & V-2 ACCURACY PROPERTY BOUNDARY 2. BEARINGS REFER TO CONNECTICUT STATE PLANE COORDINATES NAD 83 AS ESTABLISHED USING GPS SURVEY METHODS IN MARCH, 2023. (CONNECTICUT STATE PLANE) CREEK BANK 3. ELEVATIONS REFER TO THE 1988 NORTH AMERICAN VERTICAL DATUM (NAVD 88) AS DERIVED USING GLOBAL NAVIGATION SATELLITE SYSTEM (GNSS) SURVEY METHODS IN MARCH, 2023. 4. SURVEY PERFORMED BY KCI TECHNOLOGIES, INC. IN MARCH, 2023. ADDITIONAL SURVEY DATA COLLECTED BY WESTON & SAMPSON IN JUNE 2023. OTHER PLAN INFORMATION WAS GENERATED FROM PUBLICLY AVAILABLE GEOGRAPHIC INFORMATION SYSTEMS DATABASES. 5. THE UTILITIES AS DEPICTED HEREON ARE BASED UPON OBSERVED EVIDENCE AT THE TIME OF THE FIELD SURVEY. NO ATTEMPT WAS MADE TO VERIFY THE LOCATIONS AND NO MAPPING WAS OBTAINED FROM THE RESPECTIVE UTILITY COMPANIES, GOVERNMENTALAGENCIES AND/OR OTHER SOURCES. THESE LOCATIONS MUST BE CONSIDERED APPROXIMATE IN NATURE. ADDITIONALLY, OTHER SUCH FEATURES MAY EXIST ON THE SITE, THE EXISTENCE OF WHICH ARE UNKNOWN TO WESTON & SAMPSON. THE EXISTENCE, AND SIZE LOCATION OF ALL SUCH FEATURES MUST BE DETERMINED AND VERIFIED IN THE FIELD BY THE APPROPRIATE AUTHORITIES PRIOR TO CONSTRUCTION. CALL BEFORE YOU DIG. BUILDING THALWEG STONE WALL DRAINAGE LINE PROPERTY LINE MAJOR CONTOUR REMEDIATION OF PCB-IMPACTED STREA SEDIMENT ENVIANCE SPILL NUMBER CWC-18-00543 27 PARSONS LANE, DURHAM, CT Weston & Sampson Engineers, Inc. 712 Brook Street, Suite 103 Rocky Hill, CT 06067 [phone removed] 800.SAMPSON www.westonandsampson.com MINOR CONTOUR Consultants: Revisions: No. Date 1 Description 10/8/2024 DRAINAGE LAYOUT, APPROACH Seal: COA: E COPYRIGHT © 2020 BY WESTON & SAMPSON, PE, LS, LA, PC THIS DRAWING IS AN INSTRUMENT OF SERVICE AND IS THE PROPERTY OF WESTON & SAMPSON, PE, LS, LA, PC THIS DRAWING MAY NOT BE REPRODUCED IN WHOLE OR IN PART BY ANY MEANS WHATSOEVER WITHOUT THE EXPRESS WRITTEN CONSENT OF WESTON & SAMPSON PE, LS, LA, PC UNAUTHORIZED ALTERATION OR ADDITION TO THIS DOCUMENT IS A VIOLATION OF SECTION 7209. SUBDIVISION 2 OF THE NEW YORK STATE EDUCATION LAW. Scale: AS NOTED Date: JULY 2024 Drawn By: PRB Reviewed By: JW Approved By: PVU W&S Project No.: W&S File No.: Drawing Title: EXISTING CONDITIONS PLAN Sheet Number: C001 Rev: 1.8 Date: 10/24/2019 \\wse03.local\WSE\Projects\CT\NUSCO+Eversource\Durham - ER Spill Parson Lane\Remediation\3. Drawings\CAD\Remediation\C001 - Existing Conditions (1).dwg Issued For: COPYRIGHT © 2020 WESTON & SAMPSON, INC.
  3. Page 398 of 482

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-032 Attachment 165 Page 1416 of 1638 Project: LEGEND: BUILDING NOTES: 1. PAVEMENT STONE WALL 2. ACCESS ROAD LIMIT OF WORK TEMPORARY FENCE PROPOSED STREAM REMEDIATION AREAS (1.0 FT DEPTH) PROPOSED DRAINAGE CHANNEL REMEDIATION AREA (2.0 FT DEPTH) 3. THIS PLAN WAS GENERATED FROM A SURVEY COMPLETED BY KCI TECHNOLOGIES, INC. IN MARCH, 2023. ADDITIONAL DETAILS WERE ACQUIRED THROUGH AERIAL PHOTOGRAPHY, STATE PARCEL DATA, HISTORICAL SITE PLANS, MUNICIPAL RECORDS, AND A SITE VISIT BY WESTON & SAMPSON PERSONNEL ON JUNE 21, 2023. 4. UTILITIES DEPICTED ON THIS DRAWING WERE OBTAINED FROM RECORD DRAWINGS PROVIDED BY EVERSOURCE, ELECTRONIC PIPE LOCATING EQUIPMENT, TEST PITS, AND MUNICIPAL RECORDS. UTILITY LOCATIONS ARE APPROXIMATE. EXACT LOCATIONS SHALL BE FIELD VERIFIED VIA PRIVATE UTILITY LOCATOR AND/OR TEST PITTING, AS REQUIRED BY THE ENGINEER AND SECTION 01 14 00 - SPECIAL PROVISIONS. FOR GENERAL NOTES, REFER TO SHEET G001. 5. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN EROSION AND SEDIMENT CONTROLS (I.E. STRAW WATTLES, SILT FENCING, CATCH BASIN INLET PROTECTION) FOR THE DURATION OF THE PROJECT. AT A MINIMUM, THE CONTRACTOR SHALL INSTALL STRAW WATTLES AND SILT FENCING AS SHOWN ON THIS DRAWING AND AT ANY OTHER LOCATIONS REQUIRED TO KEEP SURFACE WATER RUNOFF WITHIN THE LIMITS OF WORK. EROSION AND SEDIMENT CONTROL MEASURES SHALL BE FURNISHED, INSTALLED, MAINTAINED, AND REPLACED BY THE CONTRACTOR AS NEEDED TO ENSURE THAT SEDIMENT-LADEN WATER DOES NOT LEAVE THE LIMITS OF WORK. SEE SPECIFICATION SECTION 01 57 19-ENVIRONMENTAL PROTECTION FOR ADDITIONAL INFORMATION. VEHICLES LEAVING THE SITE SHALL NOT CARRY OUT MUD OR DIRT FROM THE SITE ON THE VEHICLE BODY OR WHEELS. THE CONTRACTOR SHALL PERFORM INSPECTIONS OF THE ENVIRONMENTAL CONTROLS OR HAVE A CONSULTING ENGINEER PERFORM INSPECTIONS EVERY SEVEN (7) DAYS OR WITHIN 24 HOURS AFTER A STORM OF 0.5 INCH OR GREATER. INSPECTION REPORTS ARE TO BE KEPT ON FILE AT THE SITE. MAINTENANCE OR MODIFICATION TO THE ENVIRONMENTAL CONTROLS SHALL BE IMPLEMENTED AND THE INFORMATION DOCUMENTED AS RECOMMENDED BY THE ENGINEER AT NO 6. 7. 8. CREEK BANK THALWEG MAJOR CONTOUR MINOR CONTOUR 9. ADDITIONAL COST TO THE OWNER. THE CONTRACTOR WILL NOT BE ALLOWED TO DISTURB AREAS OUTSIDE OF THE LIMIT OF WORK. ANY DAMAGE TO AREAS OUTSIDE THE LIMITS OF WORK SHALL BE IMMEDIATELY REPAIRED BY THE CONTRACTOR, AS SPECIFIED IN SPECIFICATION SECTION 01 11 00 - CONTROL OF WORK AND MATERIALS, AT NO ADDITIONAL COST TO THE OWNER. CONTRACTOR TO STAKE OUT EXCAVATION AREAS FOR REVIEW AND APPROVAL BY THE ENGINEER PRIOR TO EXCAVATION. ENGINEER TO PROVIDE CONTRACTOR GPS POLYGONS OF EXCAVATION AREAS. CONTRACTOR SHALL ESTABLISH AND MAINTAIN SOIL EXCAVATION AREA LIMITS/PERIMETER USING APPROPRIATE SURVEY INSTRUMENT LAYOUT TECHNIQUES, AS WELL AS ESTABLISH VERTICAL CONTROL POINTS IN THE VICINITY OF THE SOIL EXCAVATION AREAS SUCH THAT THE DEPTHS OF EXCAVATION CAN BE READILY DETERMINED FROM INSTRUMENT SURVEY BY THE CONTRACTOR AND APPROVED BY THE ENGINEERS. EXCAVATION AREAS SHOWN ON THIS PLAN ARE APPROXIMATE LIMITS OF IMPACTED SOILS AND SHALL BE HANDLED AND DISPOSED OF IN ACCORDANCE WITH SPECIFICATION SECTION 02 61 00.16-HANDLING, TRANSPORTATION, REUSE, AND DISPOSAL OF EXCAVATED MATERIALS AND ALL RELEVANT LOCAL, STATE, AND FEDERAL REGULATIONS. THE CONTRACTOR SHALL REMOVE THE IMPACTED SOILS AND THE ENGINEER SHALL CONDUCT CONFIRMATORY SAMPLING FOR THE IMPACTED SOIL EXCAVATION AREAS. ENGINEER SHALL EXPEDITE ANALYSIS OF THE SAMPLES AND PROVIDE CONTRACTOR WITH RESULTS WITHIN 24 HOURS OF RECEIPT FROM THE LAB. CONTRACTOR SHOULD EXPECT A MINIMUM OF 2 TO 3 DAYS FOR LAB TO ANALYZE SAMPLES. CONTRACTOR MUST FURNISH ALL MATERIALS, TOOLS, AND LABOR TO REDUCE THE VOLUME OF FREE LIQUIDS REMOVED WITH STREAM SEDIMENT. CONTRACTOR SHALL INSTALL A SANDBAG DAM ON EACH HALF REMEDIATION OF PCB-IMPACTED STREA SEDIMENT ENVIANCE SPILL NUMBER CWC-18-00543 OF THE STREAM TO ACHIEVE A DRY STREAMBED. AFTER EXCAVATION OF ONE HALF OF THE STREAM, ENGINEER TO COLLECT CONFIRMATORY SAMPLES. SEE DETAIL SHEET D001, SECTION 01 12 16 - SCOPE AND SEQUENCE OF WORK , AND SECTION 31 23 19 - DEWATERING FOR ADDITIONAL INFORMATION 10. IMPACTED MATERIAL MAY BE ENCOUNTERED BEYOND THE LIMITS OF EXCAVATION IDENTIFIED ON THESE DRAWINGS. THE CONTRACTOR MAY BE REQUIRED TO EXTEND EXCAVATION ACTIVITIES, AS REQUIRED BY THE ENGINEER AND WITHIN THE LIMITS OF WORK, BASED ON CONFIRMATORY SAMPLING RESULTS. THE CONTRACTOR SHALL REMAIN RESPONSIBLE FOR EXCAVATION SUPPORT FOR THE EXTENDED AREA. COMPENSATION FOR ANY ENGINEER APPROVED ADDITIONAL EXCAVATION WILL BE BASED ON THE UNIT RATES IN THE BID FORM. 27 PARSONS LANE, DURHAM, CT 11. CONTRACTOR SHALL NOT BACKFILL EXCAVATED AREAS UNTIL OWNER HAS RECEIVED AND APPROVED CONFIRMATORY SAMPLING RESULTS. ADDITIONAL EXCAVATION MAY BE REQUIRED BASED ON CONFIRMATORY SAMPLING RESULTS. 12. BACKFILLING AND SITE RESTORATION SHALL BE PERFORMED FOLLOWING THE COMPLETION OF ALL SOIL REMOVAL ACTIVITIES AS SHOWN ON SHEET C004. 13. CONTRACTOR TO COORDINATE WITH THE TOWN TO DETERMINE THE PREFERRED TRUCK ROUTE. 14. CONTRACTOR TO CONSTRUCT TEMPORARY GRAVEL ROADS WHERE SPECIFIED ON THIS DRAWING TO ACCESS REMEDIATION AREAS AND REDUCE DAMAGE TO THE SITE. SEE SHEET D001 FOR ROAD DETAILS. Weston & Sampson Engineers, Inc. 712 Brook Street, Suite 103 Rocky Hill, CT 06067 [phone removed] 800.SAMPSON www.westonandsampson.com Consultants: 15. CONTRACTOR TO INSTALL AND MAINTAIN TEMPORARY FENCING FOR DURATION OF REMEDIATION ACTIVITIES. FENCE SHALL BE INSTALLED WHERE DEPICTED ON THIS DRAWING EXCEPT WHERE STREAM BANK MAY BE TOO STEEP. ENGINEER SHALL APPROVE FINAL TEMPORARY FENCING LOCATION. Revisions: No. Date 1 Description 10/8/2024 DRAINAGE LAYOUT, APPROACH Seal: COA: COPYRIGHT © 2020 BY WESTON & SAMPSON, PE, LS, LA, PC THIS DRAWING IS AN INSTRUMENT OF SERVICE AND IS THE PROPERTY OF WESTON & SAMPSON, PE, LS, LA, PC THIS DRAWING MAY NOT BE REPRODUCED IN WHOLE OR IN PART BY ANY MEANS WHATSOEVER WITHOUT THE EXPRESS WRITTEN CONSENT OF WESTON & SAMPSON PE, LS, LA, PC UNAUTHORIZED ALTERATION OR ADDITION TO THIS DOCUMENT IS A VIOLATION OF SECTION 7209. SUBDIVISION 2 OF THE NEW YORK STATE EDUCATION LAW. Scale: AS NOTED Date: JULY 2024 Drawn By: PRB Reviewed By: JW Approved By: PVU W&S Project No.: W&S File No.: Drawing Title: SITE PREPARATION AND REMEDIATION PLAN Sheet Number: C002 Rev: 1.8 Date: 10/24/2019 \\wse03.local\WSE\Projects\CT\NUSCO+Eversource\Durham - ER Spill Parson Lane\Remediation\3. Drawings\CAD\Remediation\C002 & C004 REMEDIATION AND RESTORATION.dwg Issued For: COPYRIGHT © 2020 WESTON & SAMPSON, INC.
  4. Page 399 of 482

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-032 Attachment 165 Page 1417 of 1638 Project: REMEDIATION OF PCB-IMPACTED STREA SEDIMENT ENVIANCE SPILL NUMBER CWC-18-00543 LEGEND: STATE LAWS AND REGULATIONS. SAWCUTTING SHALL BE CONDUCTED IN A NEGATIVE PRESSURE ENCLOSURE. SEE SPECIFICATION SCTION 02 83 90 - ABATEMENT OF PCB-CONTAINING MATERIALS FOR ADDITIONAL INFORMATION. NOTES: BUILDING 1. PAVEMENT OVERHEAD WIRE 2. PATCH AND RESTORE EXISTING SAWCUT CONCRETE SAWCUT 1FT X 1FT AREA AROUND FLOOR DRAIN, REMOVE STRUCTURE, AND FILL WITH CONCRETE 3. CHAIN LINK FENCE 4. THIS PLAN WAS GENERATED FROM A SURVEY COMPLETED BY KCI TECHNOLOGIES, INC. IN MARCH, 2023. ADDITIONAL DETAILS WERE ACQUIRED THROUGH AERIAL PHOTOGRAPHY, STATE PARCEL DATA, AND HISTORICAL SITE PLANS. UTILITIES DEPICTED ON THIS DRAWING WERE OBTAINED FROM RECORD DRAWINGS PROVIDED BY EVERSOURCE AND MUNICIPAL RECORDS. UTILITY LOCATIONS ARE APPROXIMATE. EXACT LOCATIONS SHALL BE FIELD VERIFIED VIA PRIVATE UTILITY LOCATOR AND/OR TEST PITTING, AS REQUIRED BY THE ENGINEER AND SECTION 01 14 00 - SPECIAL PROVISIONS. DRAINAGE LINES DEPICTED ON THIS PLAN WERE DETERMINED FROM DYE TESTING, ELECTRONIC PIPE LOCATING EQUIPMENT, MUNICIPAL RECORDS, AND CAMERA INSPECTIONS. CERTAIN DRAINAGE PIPES DEPICTED ARE INFERRED BASED ONLY ON SITE KNOWLEDGE, ELECTRONIC PIPE LOCATING EQUIPMENT, AND DYE TESTING. CONTRACTOR TO SAWCUT AND REMOVE MINIMUM OF 1FT X 1FT AREA AROUND FLOOR DRAINS. CONCRETE IS CONSIDERED PCB REMEDIATION WASTE AND SHALL BE HANDLED IN ACCORDANCE WITH FEDERAL AND 5. DEBRIS GENERATED RESTORATION ACTIVITIES, INCLUDING CONCRETE AND FLOOR DRAIN COVERS, SHALL BE CONSIDERED PCB REMEDIATION WASTE. DEBRIS SHALL BE SENT TO FACILITIES PERMITTED TO ACCEPT IT. 6. CONTRACTOR SHALL FURNISH ALL EQUIPMENT AND MATERIALS TO MINIMIZE DUST GENERATED FROM CONCRETE SAWCUTTING. THE CONTRACTOR SHALL USE A VACUUM WITH HEPA FILTER TO CLEAN ANY DEBRIS GENERATED DURING THE SAWCUTTING AND REMOVAL OF THE CONCRETE. 7. AFTER REMOVING FLOOR DRAIN COVERS, CONTRACTOR SHALL POUR CONCRETE IN SAWCUT AREA TO MATCH SURROUNDING CONDITIONS. SEE SPECIFICATION SECTION 03 05 00 - FIELD CONCRETE FOR ADDITIONAL INFORMATION. 8. THE CONTRACTOR WILL NOT BE ALLOWED TO DISTURB AREAS OUTSIDE OF THE LIMIT OF WORK. ANY DAMAGE TO AREAS OUTSIDE THE LIMITS OF WORK SHALL BE IMMEDIATELY REPAIRED BY THE CONTRACTOR, AS 9. SPECIFIED IN SPECIFICATION SECTION 01 11 00 - CONTROL OF WORK AND MATERIALS, AT NO ADDITIONAL COST TO THE OWNER. CONTRACTOR SHALL REPAIR EXISTING SAWCUT AREAS OF THE BATHROOM TO MATCH SURROUNDING CONDITIONS. SEE SPECIFICATION SECTION 03 05 00 - FIELD CONCRETE FOR ADDITIONAL INFORMATION. 27 PARSONS LANE, DURHAM, CT Weston & Sampson Engineers, Inc. 712 Brook Street, Suite 103 Rocky Hill, CT 06067 [phone removed] 800.SAMPSON www.westonandsampson.com Consultants: Revisions: No. Date 1 Description 10/8/2024 DRAINAGE LAYOUT, APPROACH Seal: COA: COPYRIGHT © 2020 BY WESTON & SAMPSON, PE, LS, LA, PC THIS DRAWING IS AN INSTRUMENT OF SERVICE AND IS THE PROPERTY OF WESTON & SAMPSON, PE, LS, LA, PC THIS DRAWING MAY NOT BE REPRODUCED IN WHOLE OR IN PART BY ANY MEANS WHATSOEVER WITHOUT THE EXPRESS WRITTEN CONSENT OF WESTON & SAMPSON PE, LS, LA, PC UNAUTHORIZED ALTERATION OR ADDITION TO THIS DOCUMENT IS A VIOLATION OF SECTION 7209. SUBDIVISION 2 OF THE NEW YORK STATE EDUCATION LAW. Scale: AS NOTED Date: JULY 2024 Drawn By: PRB Reviewed By: JW Approved By: PVU W&S Project No.: W&S File No.: Drawing Title: INTERIOR RESTORATION PLAN Sheet Number: C003 Rev: 1.8 Date: 10/24/2019 \\wse03.local\WSE\Projects\CT\NUSCO+Eversource\Durham - ER Spill Parson Lane\Remediation\3. Drawings\CAD\Remediation\C003 - Drainage Replacement.dwg E Issued For: COPYRIGHT © 2020 WESTON & SAMPSON, INC.
  5. Page 400 of 482

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-032 Attachment 165 Page 1418 of 1638 Project: LEGEND: BUILDING NOTES: 1. THE CONTRACTOR SHALL REMOVE ALL TEMPORARY FENCING, GATES, ENVIRONMENTAL PROTECTIONS, AND DEWATERING SYSTEMS USED DURING CONSTRUCTION. 2. THE CONTRACTOR SHALL RESTORE STREAM AS REMEDIATION WORK IS ONGOING. ONCE ONE HALF OF STREAM HAS BEEN EXCAVATED AND ENGINEER PROVIDES APPROVAL TO CONTINUE WITH OTHER HALF OF STREAM, CONTRACTOR SHALL FIRST RESTORE THE EXCAVATED SIDE OF THE STREAM PER THE NOTE BELOW. SEE SECTION 01 12 16 - SCOPE AND SEQUENCE OF WORK FOR ADDITIONAL INFORMATION. 3. BACKFILLING TO MATCH EXISTING GRADES SHALL BE IN ACCORDANCE WITH SECTION 31 00 00 - EARTHWORK. THE CONTRACTOR SHALL BACKFILL AREAS IN THE STREAM WITH CONTROLLED FILL TO WITHIN 4-INCHES OF THE EXISTING GRADES. THE REMAINING 4-INCHES SHALL BE BACKFILLED WITH CRUSHED STONE TO MATCH PREEXISTING CONDITIONS, PER SECTION 31 00 00 EARTHWORK. THE CONTRACTOR SHALL BACKFILL AS CLOSE TO EXISTING GRADE AS POSSIBLE TO PREVENT PONDING 4. CONTRACTOR SHALL RESTORE GRASS AREAS TO MATCH PREEXISTING CONDITIONS PER SECTIONS 32 91 19 - LOAMING AND SEEDING. PAVEMENT LOAM AND SEED STONE WALL TREE REMEDIATION OF PCB-IMPACTED STREA SEDIMENT ENVIANCE SPILL NUMBER CWC-18-00543 CREEK BANK THALWAG 27 PARSONS LANE, DURHAM, CT Weston & Sampson Engineers, Inc. 712 Brook Street, Suite 103 Rocky Hill, CT 06067 [phone removed] 800.SAMPSON www.westonandsampson.com Consultants: Revisions: No. Date 1 Description 10/8/2024 DRAINAGE LAYOUT, APPROACH Seal: COA: COPYRIGHT © 2020 BY WESTON & SAMPSON, PE, LS, LA, PC THIS DRAWING IS AN INSTRUMENT OF SERVICE AND IS THE PROPERTY OF WESTON & SAMPSON, PE, LS, LA, PC THIS DRAWING MAY NOT BE REPRODUCED IN WHOLE OR IN PART BY ANY MEANS WHATSOEVER WITHOUT THE EXPRESS WRITTEN CONSENT OF WESTON & SAMPSON PE, LS, LA, PC UNAUTHORIZED ALTERATION OR ADDITION TO THIS DOCUMENT IS A VIOLATION OF SECTION 7209. SUBDIVISION 2 OF THE NEW YORK STATE EDUCATION LAW. Scale: AS NOTED Date: JULY 2024 Drawn By: PRB Reviewed By: JW Approved By: PVU W&S Project No.: W&S File No.: Drawing Title: SITE RESTORATION PLAN Sheet Number: C004 Rev: 1.8 Date: 10/24/2019 \\wse03.local\WSE\Projects\CT\NUSCO+Eversource\Durham - ER Spill Parson Lane\Remediation\3. Drawings\CAD\Remediation\C002 & C004 REMEDIATION AND RESTORATION.dwg Issued For: COPYRIGHT © 2020 WESTON & SAMPSON, INC.
  6. Page 401 of 482

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-032 Attachment 165 Page 1419 of 1638 Project: CURLEX EROSION CONTROL BLANKET (ECB) LENGTH AS INDICATED SEE SPECIFICATION SECTION 01 56 26TEMPORARY CHAIN LINK FENCE GRATE AEC PREMIER STRAW WATTLE WOOD STAKE DOW A XX N SL OPE TOP OF CURLEX BLANKET 24" (MIN.) AEC PREMIER STRAW WATTLES WOOD STAKE SEDIMENT CONTROL SACK REMEDIATION OF PCB-IMPACTED STREA SEDIMENT ENVIANCE SPILL NUMBER CWC-18-00543 POST 10'-0" O.C. MAX. TOP RAIL CHAIN LINK FABRIC W/ MESH FABRIC/WIND SCREEN. 6'-0" MIN. WOOD STAKE (TYP.) TIES 1'-2" O.C. MAX. TENSION WIRE 27 PARSONS LANE, DURHAM, CT DRIVEN POSTS, BASE PLATE WITH SANDBAGS, OR CONCRETE BLOCK (TYP AT GATES AND POSTS) CATCH BASIN PROTECTION DETAIL N.T.S. NOTE: STAKE DETAIL SECTION N.T.S. SLOPE DETAIL N.T.S. WOOD STAKE T. TRENCH SLOPE SURFACE 1. 2. TYPICAL CATCH BASIN SEDIMENT CONTROL FABRIC APPLIED TO GRATE 3. FT. SEE SHEET C002 AND SPECIFICATION SECTION 01 56 26-TEMPORARY CHAIN LINK FENCE. FENCE POSTS SHALL BE SUITABLE FOR DRIVING INTO THE GROUND, ANCHORING WITH BASE PLATES, OR INSERTING IN PRECAST CONCRETE BLOCKS PER SPECIFICATION SECTION 01 56 26 -TEMPORARY CHAIN LINK FENCE. USE SANDBAGS, OR CONCRETE BLOCKS, ON BASE PLATES TO PREVENT TEMPORARY FENCE MOVEMENT. TEMPORARY CHAIN LINK FENCE AND GATE DETAIL N.T.S. ADJACENT ROLLS SHALL TIGHTLY ABUT DOW SLO N PE 24" (MIN.) 2" STRAW WATTLE F 3-4 3-4 A XX VERTICAL SPACING IS DEPENDANT ON SLOPE GRADIENT Consultants: STRAW BALES CATCH BASIN PROTECTION DETAIL N.T.S. INSTALL WATTLE IN A SHALLOW TRENCH (2-3 IN. DEEP) STRAW WATTLE INSTALLATION GUIDE N.T.S. STAKE DETAIL (ON BARE SOIL) N.T.S. Weston & Sampson Engineers, Inc. 712 Brook Street, Suite 103 Rocky Hill, CT 06067 [phone removed] 800.SAMPSON www.westonandsampson.com STREAM CENTERLINE PLASTIC SHEETING NOTES: 1. BEGIN AT THE LOCATION WHERE THE WATTLE IS TO BE INSTALLED BY EXCAVATING A 2-3" DEEP X 9" WIDE TRENCH ALONG THE CONTOUR OF THE SLOPE. EXCAVATED SOIL SHOULD BE PLACED UP-SLOPE FROM THE ANCHOR TRENCH. 2. PLACE THE WATTLE IN THE TRENCH SO THAT IT CONTOURS TO THE SOIL SURFACE. COMPACT SOIL FROM THE EXCAVATED TRENCH AGAINST THE WATTLE ON THE UPHILL SIDE. ADJACENT WATTLES SHOULD TIGHTLY ABUT. 3. SECURE THE WATTLE WITH 18-24" STAKES EVERY 3-4' AND WITH A STAKE ON EACH END. STAKES SHOULD BE DRIVEN THROUGH THE MIDDLE OF THE WATTLE LEAVING AT LEAST 2-3" OF STAKE EXTENDING ABOVE THE WATTLE. STAKES SHOULD BE DRIVEN PERPENDICULAR TO SLOPE FACE. Revisions: No. 1 STREAM BANK DRY SIDE OF STREAM Date Description 10/8/2024 DRAINAGE LAYOUT, APPROACH STREAM FLOW EXCAVATE TO 1' PROFILE 3' SANDBAGGING TO EXTEND 3' BEYOND STREAM BANK ON EACH SIDE AT A MINIMUM Seal: DRY SIDE OF STREAM TO BE EXCAVATED SANDBAGS PLACED DOWN STREAM CENTERLINE STREAM FLOW PLAN EXISTING AS SPECIFIED ON C002 STREAM DAMMING WITH SANDBAGS N.T.S. PAVEMENT 4" STONE OPE SL TING S I X E 20 MIL HDPE LINER OR APPROVED EQUAL NOTES: 1. SANDBAGS SHOULD BE PLACED TO A HEIGHT APPROXIMATELY 3-FT ABOVE CURRENT WATER LEVEL, OR HIGH ENOUGH TO PREVENT FLOWING WATER DURING A STORM FROM OVERTOPPING THE DAM. 2. ONCE EXCAVATION BEGINS, CONTRACTOR SHALL PLACE PLASTIC SHEETING ALONG SIDEWALL OF EXCAVATION, AND PLACE ADDITIONAL SANDBAGS AT BOTTOM OF EXCAVATION TO PREVENT WATER FLOW FROM COMING UNDER SANDBAG WALL. 3. DAM SHALL COMPLY WITH ALL REQUIREMENTS AS OUTLINED IN SECTION 31 23 19 - DEWATERING 12" MIN. 2' 3'-0" SLOPE TO SLUMP (TYP.) COLLECTION SUMP (SEE NOTE 1) COA: COPYRIGHT © 2020 BY WESTON & SAMPSON, PE, LS, LA, PC THIS DRAWING IS AN INSTRUMENT OF SERVICE AND IS THE PROPERTY OF WESTON & SAMPSON, PE, LS, LA, PC THIS DRAWING MAY NOT BE REPRODUCED IN WHOLE OR IN PART BY ANY MEANS WHATSOEVER WITHOUT THE EXPRESS WRITTEN CONSENT OF WESTON & SAMPSON PE, LS, LA, PC UNAUTHORIZED ALTERATION OR ADDITION TO THIS DOCUMENT IS A VIOLATION OF SECTION 7209. SUBDIVISION 2 OF THE NEW YORK STATE EDUCATION LAW. Issued For: PROFILE 4" STONE AS SPECIFIED ON C002 TEMPORARY, REMOVABLE PIPE PLUG 8-IN CLAY OR PLAN 8-IN RCP NOTES: 1. 2. 3. STORMWATER FLOW Scale: NOT TO SCALE Date: JULY 2024 Drawn By: PRB Reviewed By: JW Approved By: PVU W&S Project No.: W&S File No.: Drawing Title: VEHICLES SHALL BE BRUSH CLEANED TO REMOVE SOIL/DEBRIS PRIOR TO EXITING. IF, AS REQUIRED BY THE ENGINEER, BRUSH CLEANING IS NOT EFFECTIVE IN DECONTAMINATING VEHICLES, THEN THE CONTRACTOR SHALL WASH THE VEHICLES. WASH STATION SHALL BE CONSTRUCTED WITH A 20 MIL HDPE LINER SYSTEM TO DRAIN TO 2' DEEP HDPE LINED COLLECTION SUMP. DECONTAMINATION WATER IN THE COLLECTION SUMP SHALL BE PUMPED TO A DECONTAMINATION WATER STORAGE VESSEL AND SHALL BE APPROPRIATELY DISPOSED OF AT A LICENSED DISPOSAL FACILITY IN ACCORDANCE WITH ALL APPLICABLE FEDERAL, STATE, AND LOCAL REGULATIONS. THE ACCESS ROAD SHALL BE MAINTAINED IN A CONDITION WHICH WILL PREVENT TRACKING OR FLOWING OF SOIL/DEBRIS ONTO ADJACENT PAVED AREAS. THIS MAY REQUIRE PERIODIC TOP DRESSING WITH ADDITIONAL STONE AS CONDITIONS DEMAND AND REPAIR AND/OR CLEANOUT OF THE COLLECTION SUMP. ALL SOIL/DEBRIS SPILLED, DROPPED, WASHED OR TRACKED ONTO ADJACENT PAVEMENT MUST BE REMOVED IMMEDIATELY. PERIODIC INSPECTION AND NEEDED MAINTENANCE SHALL BE PROVIDED BY THE CONTRACTOR AFTER EACH RAIN. 1. 2. 3. TEMPORARY PLUG TO SECURELY ATTACH TO 8-IN RCP AND 8-IN CLAY DISCHARGE PIPES. FLOW SHALL NOT BE ALLOWED THROUGH TEMPORARY PLUG TEMPORARY PLUG SHALL BE 'THE PIPE PLUG' MANUFACTURED BY EVERETT J. PRESCOTT OR SIMILAR CONTRACTOR TO FULLY REMOVE PIPE PLUG ONCE CONTRACT IS COMPLETE. DETAILS TEMPORARY PLUG DETAIL N.T.S. Sheet Number: GRAVEL ACCESS ROAD / ANTI-TRACKING PAD N.T.S. D001 Rev: 1.8 Date: 10/24/2019 EXISTING SLOPE EXISTING PAVEMENT 12' MIN. \\wse03.local\WSE\Projects\CT\NUSCO+Eversource\Durham - ER Spill Parson Lane\Remediation\3. Drawings\CAD\Remediation\D001 - Details_RECOVER.dwg COLLECTION SUMP AT LOW SPOT (SEE NOTE 1) COPYRIGHT © 2020 WESTON & SAMPSON, INC.
  7. Page 402 of 482

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-032 Attachment 165 Page 1420 of 1638 The Connecticut Light and Power Company d.b.a. Eversource Energy Remediation of PCB-Impacted Stream Sediment Enviance Spill Number CWC-18-00543 27 Parsons Lane and 105 Middlefield Road Durham, Connecticut 06422 July 2024
  8. Page 403 of 482

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-032 Attachment 165 Page 1421 of 1638 TECHNICAL SPECIFICATIONS TABLE OF CONTENTS Bid Form Subsurface Data 00 03 00 00 31 32 01 GENERAL REQUIREMENTS Control of Work and Materials Scope and Sequence of Work Special Provisions Dust Control Measurement and Payment Construction Meetings Permits Construction Scheduling Submittals Health and Safety Plan Schedule of Values Temporary Facilities Signage Temporary Chain Link Fence Environmental Protection Cleaning Up Project Closeout 01 11 00 01 12 16 01 14 00 01 14 19.16 01 22 00 01 31 19 01 31 43 01 32 16 01 33 23 01 35 29 01 37 00 01 52 13 01 55 26.13 01 56 26 01 57 19 01 74 13 01 78 00 02 SITE WORK Handling, Transportation, Reuse and Disposal of Excavated Material Abatement of PCB-Containing Materials 02 61 00.16 02 83 90 03 CONCRETE Field Concrete 03 05 00 31 EARTHWORK Earthwork Dewatering 31 00 00 31 23 19 32 EXTERIOR IMPROVEMENTS Loaming and Seeding 32 91 19 i
  9. Page 404 of 482

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-032 Attachment 165 Page 1422 of 1638 APPENDICES Appendix A – Remedial Action Plan (RAP) END OF SECTION ii
  10. Page 405 of 482

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-032 Attachment 165 Page 1423 of 1638 Bid Items 27 Parsons Lane and 105 Middlefield Road, Durham, CT Item # Item Description: Qty Unit Unit Price 1 2 Remediation Material Type A-1: Removal, Transport & Disposal of PCB Remediation Waste Solids to TSCA Landfill Material Type A-2: Removal, Transport & Disposal of PCB Remediation Waste Liquids to TSCA Facility Material Type B-1: Removal, Transportation & Disposal of Non-RCRA hazardous waste designated CR02 Oily Wastewater Fixed Price Total 1 LS $ Fixed Price Total $ 35 Per Ton $ $ 1,000 Per Gallon $ $ 1,000 Per Gallon $ $ 3 4 $

Text of RSR-032 Attachment 165_Part 2.pdf

Extracted from the file · 509 pages · 549,394 characters

Text of RSR-032 Attachment 165_Part 1.pdf

Extracted from the file · 500 pages · 578,799 characters

Text of RSR-032 Attachment 164.pdf

Extracted from the file · 42 pages, 16 without text · 66,266 characters

Text of RSR-032 Attachment 163.pdf

Extracted from the file · 575 pages · 624,136 characters

Text of RSR-032 Attachment 162.pdf

Extracted from the file · 17 pages · 19,879 characters

Text of RSR-032 Attachment 161 _Part2.pdf

Extracted from the file · 609 pages · 625,572 characters

Text of RSR-032 Attachment 161 _Part1.pdf

Extracted from the file · 131 pages · 171,359 characters

Text of RSR-032 Attachment 160.pdf

Extracted from the file · 56 pages · 84,793 characters

Text of RSR-032 Attachment 159.pdf

Extracted from the file · 97 pages · 159,126 characters

Text of RSR-032 Attachment 158.pdf

Extracted from the file · 54 pages · 96,528 characters

Text of RSR-032 Attachment 157.pdf

Extracted from the file · 261 pages · 326,004 characters

Text of RSR-032 Attachment 156.pdf

Extracted from the file · 74 pages · 99,158 characters

Text of RSR-032 Attachment 155.pdf

Extracted from the file · 40 pages · 40,141 characters

Text of RSR-032 Attachment 154.pdf

Extracted from the file · 37 pages · 59,275 characters

Text of RSR-032 Attachment 153.pdf

Extracted from the file · 61 pages · 86,468 characters

Text of RSR-032 Attachment 152.pdf

Extracted from the file · 126 pages · 258,689 characters

Text of RSR-032 Attachment 151.pdf

Extracted from the file · 340 pages · 405,994 characters

Text of RSR-032 Attachment 150.pdf

Extracted from the file · 33 pages · 27,344 characters

Text of RSR-032 Attachment 149.pdf

Extracted from the file · 47 pages · 51,678 characters

Text of RSR-032 Attachment 148.pdf

Extracted from the file · 52 pages · 65,933 characters

Text of RSR-032 Attachment 147.pdf

Extracted from the file · 136 pages · 187,807 characters

Text of RSR-032 Attachment 146.pdf

Extracted from the file · 211 pages · 257,714 characters

Text of RSR-032 Attachment 145.pdf

Extracted from the file · 58 pages · 84,698 characters

Text of RSR-032 Attachment 144.pdf

Extracted from the file · 31 pages · 57,751 characters

Text of RSR-032 Attachment 143.pdf

Extracted from the file · 30 pages · 51,258 characters

Text of RSR-032 Attachment 142.pdf

Extracted from the file · 33 pages · 29,732 characters

Text of RSR-032 Attachment 141.pdf

Extracted from the file · 578 pages · 899,265 characters

Text of RSR-032 Attachment 140.pdf

Extracted from the file · 26 pages · 45,518 characters

Text of RSR-032 Attachment 139.pdf

Extracted from the file · 29 pages · 58,671 characters

Text of RSR-032 Attachment 138.pdf

Extracted from the file · 24 pages · 44,766 characters

Text of RSR-032 Attachment 137.pdf

Extracted from the file · 54 pages · 85,922 characters

Text of RSR-032 Attachment 136.pdf

Extracted from the file · 618 pages · 1,036,591 characters

Text of RSR-032 Attachment 135.pdf

Extracted from the file · 52 pages · 107,952 characters

Text of RSR-032 Attachment 134.pdf

Extracted from the file · 57 pages · 119,843 characters

Text of RSR-032 Attachment 133.pdf

Extracted from the file · 82 pages · 196,725 characters

Text of RSR-032 Attachment 132.pdf

Extracted from the file · 137 pages · 251,594 characters

Text of RSR-032 Attachment 131.pdf

Extracted from the file · 7 pages · 1,043 characters

Text of RSR-032 Attachment 130.pdf

Extracted from the file · 847 pages · 1,478,588 characters

Text of RSR-032 Attachment 129.pdf

Extracted from the file · 124 pages · 255,121 characters

Text of RSR-032 Attachment 128.pdf

Extracted from the file · 104 pages · 208,223 characters

Text of RSR-032 Attachment 127.pdf

Extracted from the file · 125 pages · 243,340 characters

Text of RSR-032 Attachment 126.pdf

Extracted from the file · 128 pages · 264,919 characters

Text of RSR-032 Attachment 125.pdf

Extracted from the file · 824 pages · 1,180,085 characters

Text of RSR-032 Attachment 124.pdf

Extracted from the file · 28 pages · 47,835 characters

Text of RSR-032 Attachment 123.pdf

Extracted from the file · 29 pages · 4,370 characters

Text of RSR-032 Attachment 122.pdf

Extracted from the file · 29 pages · 4,370 characters

Text of RSR-032 Attachment 121.pdf

Extracted from the file · 50 pages · 7,541 characters

Text of RSR-032 Attachment 120.PDF

Extracted from the file · 2 pages · 3,192 characters

Text of RSR-032 Attachment 119_Part3.pdf

Extracted from the file · 105 pages · 238,387 characters

Text of RSR-032 Attachment 119_Part2.pdf

Extracted from the file · 169 pages · 372,755 characters

Text of RSR-032 Attachment 119_Part1.pdf

Extracted from the file · 51 pages · 61,331 characters

Text of RSR-032 Attachment 118_Part6.pdf

Extracted from the file · 54 pages · 47,246 characters

Text of RSR-032 Attachment 118_Part5.pdf

Extracted from the file · 254 pages · 39,246 characters

Text of RSR-032 Attachment 118_Part4.pdf

Extracted from the file · 378 pages · 97,273 characters

Text of RSR-032 Attachment 118_Part3.pdf

Extracted from the file · 218 pages · 519,182 characters

Text of RSR-032 Attachment 118_Part2.pdf

Extracted from the file · 334 pages · 879,939 characters

Text of RSR-032 Attachment 118_Part1.pdf

Extracted from the file · 164 pages · 353,286 characters

Text of RSR-032 Attachment 117.pdf

Extracted from the file · 55 pages · 49,861 characters

Text of RSR-032 Attachment 116.pdf

Extracted from the file · 2 pages · 5,651 characters

Text of RSR-032 Attachment 115.pdf

Extracted from the file · 135 pages · 191,165 characters

Text of RSR-032 Attachment 114.pdf

Extracted from the file · 123 pages · 185,862 characters

Text of RSR-032 Attachment 113.pdf

Extracted from the file · 4 pages · 596 characters

Text of RSR-032 Attachment 112.pdf

Extracted from the file · 2 pages · 298 characters

Text of RSR-032 Attachment 111.pdf

Extracted from the file · 42 pages · 123,247 characters

Text of RSR-032 Attachment 110.pdf

Extracted from the file · 38 pages · 8,159 characters

Text of RSR-032 Attachment 109.pdf

Extracted from the file · 1 page · 149 characters

Text of RSR-032 Attachment 108.pdf

Extracted from the file · 23 pages · 27,882 characters

Text of RSR-032 Attachment 107.pdf

Extracted from the file · 1 page · 243 characters

Text of RSR-032 Attachment 106.pdf

Extracted from the file · 1 page · 321 characters

Text of RSR-032 Attachment 105.pdf

Extracted from the file · 493 pages · 1,262,208 characters

Text of RSR-032 Attachment 104.pdf

Extracted from the file · 628 pages · 1,570,354 characters

Text of RSR-032 Attachment 103.pdf

Extracted from the file · 40 pages · 129,345 characters

Text of RSR-032 Attachment 102.pdf

Extracted from the file · 2 pages · 298 characters

Text of RSR-032 Attachment 101.pdf

Extracted from the file · 186 pages · 437,630 characters

Text of RSR-032 Attachment 100.pdf

Extracted from the file · 244 pages · 509,938 characters

Text of RSR-032 Attachment 99.pdf

Extracted from the file · 193 pages · 412,257 characters

Text of RSR-032 Attachment 98.pdf

Extracted from the file · 2,201 pages · 3,529,384 characters

Text of RSR-032 Attachment 97.pdf

Extracted from the file · 2 pages · 2,870 characters

Text of RSR-032 Attachment 96.pdf

Extracted from the file · 2 pages · 296 characters

Text of RSR-032 Attachment 95.pdf

Extracted from the file · 27 pages · 8,963 characters

Text of RSR-032 Attachment 94.pdf

Extracted from the file · 3 pages · 5,367 characters

Text of RSR-032 Attachment 93.pdf

Extracted from the file · 3 pages · 5,315 characters

Text of RSR-032 Attachment 92.pdf

Extracted from the file · 3 pages · 5,225 characters

Text of RSR-032 Attachment 91.pdf

Extracted from the file · 2 pages · 2,709 characters

Text of RSR-032 Attachment 90.pdf

Extracted from the file · 2 pages · 2,630 characters

Text of RSR-032 Attachment 89.pdf

Extracted from the file · 2 pages · 2,615 characters

Text of RSR-032 Attachment 88.pdf

Extracted from the file · 2 pages · 2,771 characters

Text of RSR-032 Attachment 87.pdf

Extracted from the file · 2 pages · 2,948 characters

Text of RSR-032 Attachment 86.pdf

Extracted from the file · 2 pages · 2,772 characters

Text of RSR-032 Attachment 85.pdf

Extracted from the file · 2 pages · 2,764 characters

Text of RSR-032 Attachment 84.pdf

Extracted from the file · 2 pages · 2,999 characters

Text of RSR-032 Attachment 83.pdf

Extracted from the file · 2 pages · 2,995 characters

Text of RSR-032 Attachment 82.pdf

Extracted from the file · 2 pages · 2,968 characters

Text of RSR-032 Attachment 81.pdf

Extracted from the file · 2 pages · 2,973 characters

Text of RSR-032 Attachment 80.pdf

Extracted from the file · 2 pages · 296 characters

Text of RSR-032 Attachment 79.pdf

Extracted from the file · 2 pages · 2,694 characters

Text of RSR-032 Attachment 78.pdf

Extracted from the file · 3 pages · 3,876 characters

Text of RSR-032 Attachment 77.pdf

Extracted from the file · 3 pages · 3,646 characters

Text of RSR-032 Attachment 76.pdf

Extracted from the file · 3 pages · 3,805 characters

Text of RSR-032 Attachment 75.pdf

Extracted from the file · 9 pages · 13,840 characters

Text of RSR-032 Attachment 74.pdf

Extracted from the file · 3 pages · 3,990 characters

Text of RSR-032 Attachment 73.pdf

Extracted from the file · 3 pages · 4,170 characters

Text of RSR-032 Attachment 72.pdf

Extracted from the file · 3 pages · 3,957 characters

Text of RSR-032 Attachment 71.pdf

Extracted from the file · 3 pages · 3,642 characters

Text of RSR-032 Attachment 70.pdf

Extracted from the file · 2 pages · 2,078 characters

Text of RSR-032 Attachment 69.pdf

Extracted from the file · 3 pages · 4,357 characters

Text of RSR-032 Attachment 68.pdf

Extracted from the file · 3 pages · 3,165 characters

Text of RSR-032 Attachment 67.pdf

Extracted from the file · 4 pages · 3,715 characters

Text of RSR-032 Attachment 66.pdf

Extracted from the file · 3 pages · 3,168 characters

Text of RSR-032 Attachment 65.pdf

Extracted from the file · 3 pages · 444 characters

Text of RSR-032 Attachment 64.pdf

Extracted from the file · 2 pages · 2,099 characters

Text of RSR-032 Attachment 63.pdf

Extracted from the file · 2 pages · 2,062 characters

Text of RSR-032 Attachment 62.pdf

Extracted from the file · 7 pages · 5,200 characters

Text of RSR-032 Attachment 61.pdf

Extracted from the file · 5 pages · 10,643 characters

Text of RSR-032 Attachment 60.pdf

Extracted from the file · 2 pages · 296 characters

Text of RSR-032 Attachment 59.pdf

Extracted from the file · 2 pages · 4,147 characters

Text of RSR-032 Attachment 58.pdf

Extracted from the file · 1 page · 2,448 characters

Text of RSR-032 Attachment 57.pdf

Extracted from the file · 2 pages · 296 characters

Text of RSR-032 Attachment 56.pdf

Extracted from the file · 10 pages · 1,491 characters

Text of RSR-032 Attachment 55_Part10.pdf

Extracted from the file · 286 pages · 344,076 characters

Text of RSR-032 Attachment 55_Part9.pdf

Extracted from the file · 500 pages · 957,292 characters

Text of RSR-032 Attachment 55_Part8.pdf

Extracted from the file · 500 pages · 874,750 characters

Text of RSR-032 Attachment 55_Part7.pdf

Extracted from the file · 500 pages · 470,022 characters

Text of RSR-032 Attachment 55_Part6.pdf

Extracted from the file · 500 pages · 494,317 characters

Text of RSR-032 Attachment 55_Part5.pdf

Extracted from the file · 500 pages · 461,760 characters

Text of RSR-032 Attachment 55_Part4.pdf

Extracted from the file · 500 pages · 492,694 characters

Text of RSR-032 Attachment 55_Part3.pdf

Extracted from the file · 500 pages · 580,603 characters

Text of RSR-032 Attachment 55_Part2.pdf

Extracted from the file · 500 pages · 483,371 characters

Text of RSR-032 Attachment 55_Part1.pdf

Extracted from the file · 500 pages · 881,595 characters

Text of RSR-032 Attachment 54.pdf

Extracted from the file · 121 pages · 447,477 characters

Text of RSR-032 Attachment 53.pdf

Extracted from the file · 204 pages · 625,248 characters

Text of RSR-032 Attachment 52.pdf

Extracted from the file · 130 pages · 298,641 characters

Text of RSR-032 Attachment 51.pdf

Extracted from the file · 57 pages · 123,610 characters

Text of RSR-032 Attachment 50.pdf

Extracted from the file · 6 pages · 8,050 characters

Text of RSR-032 Attachment 49.pdf

Extracted from the file · 83 pages · 194,182 characters

Text of RSR-032 Attachment 48.pdf

Extracted from the file · 3 pages · 8,556 characters

Text of RSR-032 Attachment 47.pdf

Extracted from the file · 10 pages · 14,266 characters

Text of RSR-032 Attachment 46.pdf

Extracted from the file · 7 pages · 10,783 characters

Text of RSR-032 Attachment 45.pdf

Extracted from the file · 373 pages · 490,688 characters

Text of RSR-032 Attachment 44.pdf

Extracted from the file · 38 pages · 6,799 characters

Text of RSR-032 Attachment 43.pdf

Extracted from the file · 49 pages · 83,514 characters

Text of RSR-032 Attachment 42.pdf

Extracted from the file · 25 pages, 14 without text · 13,836 characters

Text of RSR-032 Attachment 41.pdf

Extracted from the file · 3 pages · 5,506 characters

Text of RSR-032 Attachment 40.pdf

Extracted from the file · 1 page · 1,448 characters

Text of RSR-032 Attachment 39.pdf

Extracted from the file · 14 pages · 17,145 characters

Text of RSR-032 Attachment 38.pdf

Extracted from the file · 12 pages · 14,555 characters

Text of RSR-032 Attachment 37.pdf

Extracted from the file · 12 pages · 14,398 characters

Text of RSR-032 Attachment 36.pdf

Extracted from the file · 12 pages · 15,426 characters

Text of RSR-032 Attachment 35.pdf

Extracted from the file · 38 pages · 61,388 characters

Text of RSR-032 Attachment 34.pdf

Extracted from the file · 13 pages · 12,161 characters

Text of RSR-032 Attachment 33.pdf

Extracted from the file · 11 pages · 7,928 characters

Text of RSR-032 Attachment 32.pdf

Extracted from the file · 3 pages · 444 characters

Text of RSR-032 Attachment 31.pdf

Extracted from the file · 26 pages · 3,891 characters

Text of RSR-032 Attachment 30.pdf

Extracted from the file · 18 pages · 2,691 characters

Text of RSR-032 Attachment 29.pdf

Extracted from the file · 9 pages · 10,238 characters

Text of RSR-032 Attachment 28.pdf

Extracted from the file · 127 pages · 218,825 characters

Text of RSR-032 Attachment 27.pdf

Extracted from the file · 12 pages · 12,858 characters

Text of RSR-032 Attachment 26.pdf

Extracted from the file · 12 pages · 14,742 characters

Text of RSR-032 Attachment 25.pdf

Extracted from the file · 14 pages · 16,968 characters

Text of RSR-032 Attachment 24.pdf

Extracted from the file · 13 pages · 16,061 characters

Text of RSR-032 Attachment 23.pdf

Extracted from the file · 19 pages · 8,357 characters

Text of RSR-032 Attachment 22.pdf

Extracted from the file · 1,282 pages · 3,304,505 characters

Text of RSR-032 Attachment 21.pdf

Extracted from the file · 1,005 pages · 2,609,640 characters

Text of RSR-032 Attachment 20_Part2.pdf

Extracted from the file · 109 pages · 16,568 characters

Text of RSR-032 Attachment 20_Part1.pdf

Extracted from the file · 150 pages · 190,904 characters

Text of RSR-032 Attachment 19.pdf

Extracted from the file · 23 pages · 39,103 characters

Text of RSR-032 Attachment 18.pdf

Extracted from the file · 8 pages · 12,671 characters

Text of RSR-032 Attachment 17_Part3.pdf

Extracted from the file · 282 pages · 740,441 characters

Text of RSR-032 Attachment 17_Part2.pdf

Extracted from the file · 500 pages · 1,293,274 characters

Text of RSR-032 Attachment 17_Part1.pdf

Extracted from the file · 500 pages · 1,270,790 characters

Text of RSR-032 Attachment 16.pdf

Extracted from the file · 46 pages · 130,280 characters

Text of RSR-032 Attachment 15.pdf

Extracted from the file · 17 pages · 25,967 characters

Text of RSR-032 Attachment 14.pdf

Extracted from the file · 10 pages · 15,944 characters

Text of RSR-032 Attachment 13.pdf

Extracted from the file · 17 pages · 29,849 characters

Text of RSR-032 Attachment 12.pdf

Extracted from the file · 12 pages · 20,731 characters

Text of RSR-032 Attachment 11.pdf

Extracted from the file · 15 pages · 23,899 characters

Text of RSR-032 Attachment 10.pdf

Extracted from the file · 145 pages · 332,684 characters

Text of RSR-032 Attachment 9.pdf

Extracted from the file · 897 pages · 1,943,866 characters

Text of RSR-032 Attachment 8.pdf

Extracted from the file · 203 pages · 512,054 characters

Text of RSR-032 Attachment 7.pdf

Extracted from the file · 12 pages · 13,977 characters

Text of RSR-032 Attachment 6.pdf

Extracted from the file · 335 pages · 685,056 characters

Text of RSR-032 Attachment 5.pdf

Extracted from the file · 65 pages · 194,221 characters

Text of RSR-032 Attachment 4.pdf

Extracted from the file · 570 pages · 1,357,502 characters

Text of RSR-032 Attachment 3.pdf

Extracted from the file · 8 pages · 15,762 characters

Text of RSR-032 Attachment 2.pdf

Extracted from the file · 26 pages · 3,865 characters

Text of RSR-032 Attachment 1.pdf

Extracted from the file · 18 pages · 2,673 characters

As listed on the current system

Question(s) Answered 32 (Connecticut Light and Power Company dba Eversource Energy) Date Filed: 10/30/2026

This filing on the current system (opens in a new tab)