Skip to main content

A prototype public docket site for the Connecticut Public Utilities Regulatory Authority

Utility Dockets and Filings

Interrogatory responses

Answers to questions 32

ResponseFiled by Connecticut Light and Power Company dba Eversource Energy210 files
Part of docket 26-05-10Open
  • Electric
Application of The Connecticut Light and Power Company d/b/a Eversource Energy to Amend its Rate Schedules

Files210

Search terms highlighted
Eversource rate increase is on 9 pages across 3 files of the text below, highlighted. Go to the first matchClear highlighting
Words on different pages
Words on different pages
Words on different pages

Text of RSR-032 Attachment 176_Part2.pdf

Extracted from the file · 754 pages · 1,598,897 characters

Text of RSR-032 Attachment 176_Part1.pdf

Extracted from the file · 110 pages · 439,601 characters

Text of RSR-032 Attachment 175_Part7.pdf

Extracted from the file · 275 pages · 622,526 characters

Text of RSR-032 Attachment 175_Part6.pdf

Extracted from the file · 350 pages · 828,421 characters

Text of RSR-032 Attachment 175_Part5.pdf

Extracted from the file · 350 pages · 841,526 characters

Text of RSR-032 Attachment 175_Part4.pdf

Extracted from the file · 350 pages · 529,828 characters

Text of RSR-032 Attachment 175_Part3.pdf

Extracted from the file · 350 pages · 417,827 characters

Text of RSR-032 Attachment 175_Part2.pdf

Extracted from the file · 350 pages · 717,402 characters

Text of RSR-032 Attachment 175_Part1.pdf

Extracted from the file · 350 pages · 426,888 characters

Text of RSR-032 Attachment 174.pdf

Extracted from the file · 2 pages · 3,788 characters

Text of RSR-032 Attachment 173.pdf

Extracted from the file · 9 pages · 19,276 characters

Text of RSR-032 Attachment 172.pdf

Extracted from the file · 2 pages · 5,216 characters

Text of RSR-032 Attachment 171.pdf

Extracted from the file · 2 pages · 7,025 characters

Text of RSR-032 Attachment 170.pdf

Extracted from the file · 4 pages · 596 characters

Text of RSR-032 Attachment 169.pdf

Extracted from the file · 14 pages · 2,105 characters

Text of RSR-032 Attachment 168.pdf

Extracted from the file · 178 pages · 303,260 characters

Text of RSR-032 Attachment 167_Part2.pdf

Extracted from the file · 844 pages · 1,367,165 characters

Text of RSR-032 Attachment 167_Part1.pdf

Extracted from the file · 284 pages · 480,797 characters

Text of RSR-032 Attachment 166.pdf

Extracted from the file · 4 pages · 5,984 characters

Text of RSR-032 Attachment 165_Part 4.pdf

Extracted from the file · 84 pages · 130,960 characters

Text of RSR-032 Attachment 165_Part 3.pdf

Extracted from the file · 482 pages · 674,897 characters

Text of RSR-032 Attachment 165_Part 2.pdf

Extracted from the file · 509 pages · 549,394 characters

Text of RSR-032 Attachment 165_Part 1.pdf

Extracted from the file · 500 pages · 578,799 characters

Text of RSR-032 Attachment 164.pdf

Extracted from the file · 42 pages, 16 without text · 66,266 characters

Text of RSR-032 Attachment 163.pdf

Extracted from the file · 575 pages · 624,136 characters

Text of RSR-032 Attachment 162.pdf

Extracted from the file · 17 pages · 19,879 characters

Text of RSR-032 Attachment 161 _Part2.pdf

Extracted from the file · 609 pages · 625,572 characters

Text of RSR-032 Attachment 161 _Part1.pdf

Extracted from the file · 131 pages · 171,359 characters

Text of RSR-032 Attachment 160.pdf

Extracted from the file · 56 pages · 84,793 characters

Text of RSR-032 Attachment 159.pdf

Extracted from the file · 97 pages · 159,126 characters

Text of RSR-032 Attachment 158.pdf

Extracted from the file · 54 pages · 96,528 characters

Text of RSR-032 Attachment 157.pdf

Extracted from the file · 261 pages · 326,004 characters

Text of RSR-032 Attachment 156.pdf

Extracted from the file · 74 pages · 99,158 characters

Text of RSR-032 Attachment 155.pdf

Extracted from the file · 40 pages · 40,141 characters

Text of RSR-032 Attachment 154.pdf

Extracted from the file · 37 pages · 59,275 characters

Text of RSR-032 Attachment 153.pdf

Extracted from the file · 61 pages · 86,468 characters

Text of RSR-032 Attachment 152.pdf

Extracted from the file · 126 pages · 258,689 characters

Text of RSR-032 Attachment 151.pdf

Extracted from the file · 340 pages · 405,994 characters

Text of RSR-032 Attachment 150.pdf

Extracted from the file · 33 pages · 27,344 characters

Text of RSR-032 Attachment 149.pdf

Extracted from the file · 47 pages · 51,678 characters

Text of RSR-032 Attachment 148.pdf

Extracted from the file · 52 pages · 65,933 characters

Text of RSR-032 Attachment 147.pdf

Extracted from the file · 136 pages · 187,807 characters

Text of RSR-032 Attachment 146.pdf

Extracted from the file · 211 pages · 257,714 characters

Text of RSR-032 Attachment 145.pdf

Extracted from the file · 58 pages · 84,698 characters

Text of RSR-032 Attachment 144.pdf

Extracted from the file · 31 pages · 57,751 characters

Text of RSR-032 Attachment 143.pdf

Extracted from the file · 30 pages · 51,258 characters

Text of RSR-032 Attachment 142.pdf

Extracted from the file · 33 pages · 29,732 characters

Text of RSR-032 Attachment 141.pdf

Extracted from the file · 578 pages · 899,265 characters

Text of RSR-032 Attachment 140.pdf

Extracted from the file · 26 pages · 45,518 characters

Text of RSR-032 Attachment 139.pdf

Extracted from the file · 29 pages · 58,671 characters

Text of RSR-032 Attachment 138.pdf

Extracted from the file · 24 pages · 44,766 characters

Text of RSR-032 Attachment 137.pdf

Extracted from the file · 54 pages · 85,922 characters

Text of RSR-032 Attachment 136.pdf

Extracted from the file · 618 pages · 1,036,591 characters

Text of RSR-032 Attachment 135.pdf

Extracted from the file · 52 pages · 107,952 characters

Text of RSR-032 Attachment 134.pdf

Extracted from the file · 57 pages · 119,843 characters

Text of RSR-032 Attachment 133.pdf

Extracted from the file · 82 pages · 196,725 characters

Text of RSR-032 Attachment 132.pdf

Extracted from the file · 137 pages · 251,594 characters

Text of RSR-032 Attachment 131.pdf

Extracted from the file · 7 pages · 1,043 characters

Text of RSR-032 Attachment 130.pdf

Extracted from the file · 847 pages · 1,478,588 characters

Text of RSR-032 Attachment 129.pdf

Extracted from the file · 124 pages · 255,121 characters

Text of RSR-032 Attachment 128.pdf

Extracted from the file · 104 pages · 208,223 characters

Text of RSR-032 Attachment 127.pdf

Extracted from the file · 125 pages · 243,340 characters

Text of RSR-032 Attachment 126.pdf

Extracted from the file · 128 pages · 264,919 characters

Text of RSR-032 Attachment 125.pdf

Extracted from the file · 824 pages · 1,180,085 characters

Text of RSR-032 Attachment 124.pdf

Extracted from the file · 28 pages · 47,835 characters

Text of RSR-032 Attachment 123.pdf

Extracted from the file · 29 pages · 4,370 characters

Text of RSR-032 Attachment 122.pdf

Extracted from the file · 29 pages · 4,370 characters

Text of RSR-032 Attachment 121.pdf

Extracted from the file · 50 pages · 7,541 characters

Text of RSR-032 Attachment 120.PDF

Extracted from the file · 2 pages · 3,192 characters

Text of RSR-032 Attachment 119_Part3.pdf

Extracted from the file · 105 pages · 238,387 characters

Text of RSR-032 Attachment 119_Part2.pdf

Extracted from the file · 169 pages · 372,755 characters

Text of RSR-032 Attachment 119_Part1.pdf

Extracted from the file · 51 pages · 61,331 characters

Text of RSR-032 Attachment 118_Part6.pdf

Extracted from the file · 54 pages · 47,246 characters

Text of RSR-032 Attachment 118_Part5.pdf

Extracted from the file · 254 pages · 39,246 characters

Text of RSR-032 Attachment 118_Part4.pdf

Extracted from the file · 378 pages · 97,273 characters

Text of RSR-032 Attachment 118_Part3.pdf

Extracted from the file · 218 pages · 519,182 characters

Text of RSR-032 Attachment 118_Part2.pdf

Extracted from the file · 334 pages · 879,939 characters

Text of RSR-032 Attachment 118_Part1.pdf

Extracted from the file · 164 pages · 353,286 characters

Text of RSR-032 Attachment 117.pdf

Extracted from the file · 55 pages · 49,861 characters

Text of RSR-032 Attachment 116.pdf

Extracted from the file · 2 pages · 5,651 characters

Text of RSR-032 Attachment 115.pdf

Extracted from the file · 135 pages · 191,165 characters

Text of RSR-032 Attachment 114.pdf

Extracted from the file · 123 pages · 185,862 characters

Text of RSR-032 Attachment 113.pdf

Extracted from the file · 4 pages · 596 characters

Text of RSR-032 Attachment 112.pdf

Extracted from the file · 2 pages · 298 characters

Text of RSR-032 Attachment 111.pdf

Extracted from the file · 42 pages · 123,247 characters

Text of RSR-032 Attachment 110.pdf

Extracted from the file · 38 pages · 8,159 characters

Text of RSR-032 Attachment 109.pdf

Extracted from the file · 1 page · 149 characters

Text of RSR-032 Attachment 108.pdf

Extracted from the file · 23 pages · 27,882 characters

Text of RSR-032 Attachment 107.pdf

Extracted from the file · 1 page · 243 characters

Text of RSR-032 Attachment 106.pdf

Extracted from the file · 1 page · 321 characters

Text of RSR-032 Attachment 105.pdf

Extracted from the file · 493 pages · 1,262,208 characters

Text of RSR-032 Attachment 104.pdf

Extracted from the file · 628 pages · 1,570,354 characters

Text of RSR-032 Attachment 103.pdf

Extracted from the file · 40 pages · 129,345 characters

Text of RSR-032 Attachment 102.pdf

Extracted from the file · 2 pages · 298 characters

Text of RSR-032 Attachment 101.pdf

Extracted from the file · 186 pages · 437,630 characters

Text of RSR-032 Attachment 100.pdf

Extracted from the file · 244 pages · 509,938 characters

Text of RSR-032 Attachment 99.pdf

Extracted from the file · 193 pages · 412,257 characters

Text of RSR-032 Attachment 98.pdf

Extracted from the file · 2,201 pages · 3,529,384 characters

Text of RSR-032 Attachment 97.pdf

Extracted from the file · 2 pages · 2,870 characters

Text of RSR-032 Attachment 96.pdf

Extracted from the file · 2 pages · 296 characters

Text of RSR-032 Attachment 95.pdf

Extracted from the file · 27 pages · 8,963 characters

Text of RSR-032 Attachment 94.pdf

Extracted from the file · 3 pages · 5,367 characters

Text of RSR-032 Attachment 93.pdf

Extracted from the file · 3 pages · 5,315 characters

Text of RSR-032 Attachment 92.pdf

Extracted from the file · 3 pages · 5,225 characters

Text of RSR-032 Attachment 91.pdf

Extracted from the file · 2 pages · 2,709 characters

Text of RSR-032 Attachment 90.pdf

Extracted from the file · 2 pages · 2,630 characters

Text of RSR-032 Attachment 89.pdf

Extracted from the file · 2 pages · 2,615 characters

Text of RSR-032 Attachment 88.pdf

Extracted from the file · 2 pages · 2,771 characters

Text of RSR-032 Attachment 87.pdf

Extracted from the file · 2 pages · 2,948 characters

Text of RSR-032 Attachment 86.pdf

Extracted from the file · 2 pages · 2,772 characters

Text of RSR-032 Attachment 85.pdf

Extracted from the file · 2 pages · 2,764 characters

Text of RSR-032 Attachment 84.pdf

Extracted from the file · 2 pages · 2,999 characters

Text of RSR-032 Attachment 83.pdf

Extracted from the file · 2 pages · 2,995 characters

Text of RSR-032 Attachment 82.pdf

Extracted from the file · 2 pages · 2,968 characters

Text of RSR-032 Attachment 81.pdf

Extracted from the file · 2 pages · 2,973 characters

Text of RSR-032 Attachment 80.pdf

Extracted from the file · 2 pages · 296 characters

Text of RSR-032 Attachment 79.pdf

Extracted from the file · 2 pages · 2,694 characters

Text of RSR-032 Attachment 78.pdf

Extracted from the file · 3 pages · 3,876 characters

Text of RSR-032 Attachment 77.pdf

Extracted from the file · 3 pages · 3,646 characters

Text of RSR-032 Attachment 76.pdf

Extracted from the file · 3 pages · 3,805 characters

Text of RSR-032 Attachment 75.pdf

Extracted from the file · 9 pages · 13,840 characters

Text of RSR-032 Attachment 74.pdf

Extracted from the file · 3 pages · 3,990 characters

Text of RSR-032 Attachment 73.pdf

Extracted from the file · 3 pages · 4,170 characters

Text of RSR-032 Attachment 72.pdf

Extracted from the file · 3 pages · 3,957 characters

Text of RSR-032 Attachment 71.pdf

Extracted from the file · 3 pages · 3,642 characters

Text of RSR-032 Attachment 70.pdf

Extracted from the file · 2 pages · 2,078 characters

Text of RSR-032 Attachment 69.pdf

Extracted from the file · 3 pages · 4,357 characters

Text of RSR-032 Attachment 68.pdf

Extracted from the file · 3 pages · 3,165 characters

Text of RSR-032 Attachment 67.pdf

Extracted from the file · 4 pages · 3,715 characters

Text of RSR-032 Attachment 66.pdf

Extracted from the file · 3 pages · 3,168 characters

Text of RSR-032 Attachment 65.pdf

Extracted from the file · 3 pages · 444 characters

Text of RSR-032 Attachment 64.pdf

Extracted from the file · 2 pages · 2,099 characters

Text of RSR-032 Attachment 63.pdf

Extracted from the file · 2 pages · 2,062 characters

Text of RSR-032 Attachment 62.pdf

Extracted from the file · 7 pages · 5,200 characters

Text of RSR-032 Attachment 61.pdf

Extracted from the file · 5 pages · 10,643 characters

Text of RSR-032 Attachment 60.pdf

Extracted from the file · 2 pages · 296 characters

Text of RSR-032 Attachment 59.pdf

Extracted from the file · 2 pages · 4,147 characters

Text of RSR-032 Attachment 58.pdf

Extracted from the file · 1 page · 2,448 characters

Text of RSR-032 Attachment 57.pdf

Extracted from the file · 2 pages · 296 characters

Text of RSR-032 Attachment 56.pdf

Extracted from the file · 10 pages · 1,491 characters

Text of RSR-032 Attachment 55_Part10.pdf

Extracted from the file · 286 pages · 344,076 characters

Text of RSR-032 Attachment 55_Part9.pdf

Extracted from the file · 500 pages · 957,292 characters

Text of RSR-032 Attachment 55_Part8.pdf

Extracted from the file · 500 pages · 874,750 characters

Text of RSR-032 Attachment 55_Part7.pdf

Extracted from the file · 500 pages · 470,022 characters

Text of RSR-032 Attachment 55_Part6.pdf

Extracted from the file · 500 pages · 494,317 characters

Text of RSR-032 Attachment 55_Part5.pdf

Extracted from the file · 500 pages · 461,760 characters

Text of RSR-032 Attachment 55_Part4.pdf

Extracted from the file · 500 pages · 492,694 characters

Text of RSR-032 Attachment 55_Part3.pdf

Extracted from the file · 500 pages · 580,603 characters

Text of RSR-032 Attachment 55_Part2.pdf

Extracted from the file · 500 pages · 483,371 characters

Words on different pages
  1. Page 62 of 500

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-032 Attachment 55 Page 62 of 4786 Table 2 Summary of Previous and Proposed Soil Sample Borings Berlin Settling Basin Berlin, Connecticut January 2012 SAMPLE LOCATION 5 SAMPLE DEPTH (feet below grade) 0-0.5 0.5-1.0 1.0-1.5 1.5-2.0 2.0-2.5 2.5-3.0 3.0-3.5 3.5-4.0 4.0-6.0 6.0-6.5 6.5-7.0 7.5-8.0 8.0-10.0 x (c) x (c) x (c) x (c) x (c) x (c) x (c) x (c) x (c) x (c) x (c) x (c) x (c) x (c) x (c) x (c) x (c) x (c) x (c) x (c) B-122 5 B-123 5 B-124 5 B-125 5 B-126 5 B-127 5 B-128 5 B-129 5 B-130 B-131 5 Notes: 1 Location of previous soil samples collected by Weston&Sampson Engineers (December 2011). Values represent total PCBs (mg/kg). 2 3 4 5 Location of previous soil samples collected by NUSCO (July 2010). Values represent total PCBs (mg/kg). BDL means result of sample analysis was below laboratory reporting limit. X represents depths of which soil samples will be collected. X (c) means the soil sampled at this location will be composited with a sample collected from the same depth interval at an adjacent test boring. Total PCBs exceeds RES DEC Total PCBs exceeds RES DEC & I/C DEC Total PCBs exceeds RES DEC, I/C DEC & 50 mg/kg PCB
  2. Page 63 of 500

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-032 Attachment 55 Page 63 of 4786 APPENDIX B SELF-IMPLEMENTING AND RISK-BASED HYBRID CLEANUP PLAN, SEPTEMBER 2015
  3. Page 64 of 500

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-032 Attachment 55 Page 64 of 4786 Environmental Affairs Department 107 Selden Street Berlin, Connecticut 06037 September 30, 2015 Ms. Kimberly N. Tisa, PCB Coordinator (OSRR07-2) United State Environmental Protection Agency – Region 1 5 Post Office Square, Suite 100 Boston, MA 02109-3912 Re: Self-Implementing and Risk-Based Hybrid Cleanup Plan Eversource Energy - Berlin Campus Settling Basin 107 Selden Street Berlin, Connecticut Dear Ms. Tisa: Eversource Energy (Eversource) is pleased to submit the attached Self-Implementing and RiskBased Hybrid Cleanup Plan (Plan) prepared by Weston & Sampson Engineers (Weston & Sampson) for the pre-characterization, removal, disposal, and remediation of soil impacted with polychlorinated biphenyls (PCBs) at the storm water settling basin and adjacent upland/wooded area on Eversource’s Berlin Campus located at 107 Selden Street in Berlin, Connecticut (the Site). Pre-characterization sampling has been completed in accordance with 40 CFR 761.61(a) Subpart N, the Self-Implementing On-Site Cleanup and Disposal of PCB Remediation Waste. Several variations from Subpart N are proposed in the Plan, hence the attached Plan represents a hybrid self-implementing (40 CFR 761.61(a)) and a risk-based (40 CFR 761.61(c)) cleanup approach. The Plan presents the results of the pre-characterization program and serves as the notification and certification of cleanup activities planned for the Site, as required by 40 CFR 761.61. This notification has also been submitted to the Connecticut Department of Energy and Environmental Protection and the Central Office for the Central Connecticut Health District. If you have any questions regarding the attached, please contact Christopher Soroka from Eversource Energy at [phone removed] or Kenneth Gendron from Weston & Sampson at [phone removed], ext. 2501. Very truly yours, EVERSOURCE ENERGY __________________________________________________________ Christopher A. Soroka, Senior Environmental Specialist for Daniel Watton, Manager – Environmental Cost, Risk and Site Management Enclosure cc: Gary Trombly, CTDEEP – PCB Program Paul Hutcheon, Central Connecticut Health District – Central Office Malcolm Beeler, Weston & Sampson
  4. Page 65 of 500

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-032 Attachment 55 Page 65 of 4786 report Self-Implementing and Risk-Based Hybrid Cleanup Plan Eversource Energy – Berlin Campus Stormwater Settling Basin 107 Selden Street Berlin, Connecticut Prepared on behalf of: Eversource Energy 107 Selden Street Berlin, Connecticut September 2015
  5. Page 66 of 500

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-032 Attachment 55 Page 66 of 4786 Berlin Campus Settling Basin Self-Implementing & Risk-Based Cleanup Plan TABLE OF CONTENTS September 2015 Page LIST OF FIGURES ..................................................................................................................... ii LIST OF TABLES........................................................................................................................ ii LIST OF APPENDICES .............................................................................................................. ii 1.0 1.1 1.2 INTRODUCTION ..........................................................................................................1-1 Applicability ............................................................................................................. 1-1 Notifications ............................................................................................................. 1-2 2.0 SITE DESCRIPTION ....................................................................................................2-1 2.1 Conceptual Site Model............................................................................................. 2-1 3.0 NOTIFICATION AND CERTIFICATION .......................................................................3-1 3.1 The Nature of Impacts ............................................................................................. 3-1 3.2 Summary of Assessment Procedures and Results .................................................. 3-1 3.2.1 Historic Sampling Events ..................................................................................... 3-1 3.2.2 2015 Sampling Events (May 2015-July 2015) ...................................................... 3-5 3.3 Location and Extent of the Identified Impacted Areas .............................................. 3-6 4.0 SITE CLEANUP PLAN ................................................................................................4-1 4.1 Cleanup Plan Objectives, Approach and Proposed Schedule .................................. 4-1 4.2 Air Monitoring and Environmental Protection ........................................................... 4-1 4.2.1 Erosion and Sedimentation Control Measures ..................................................... 4-1 4.2.2 Dewatering .......................................................................................................... 4-2 4.3 Off-Site Management of Soils .................................................................................. 4-2 4.4 On-Site Consolidation of Soils ................................................................................. 4-2 4.5 Engineered Barrier .................................................................................................. 4-2 4.6 Restoration .............................................................................................................. 4-3 4.7 Deed Restriction ...................................................................................................... 4-4 4.8 Storm Water Control ................................................................................................ 4-4 4.9 Cleanup Verification Soil Sampling .......................................................................... 4-4 4.10 Decontamination Wastes ......................................................................................... 4-4 5.0 REMOVAL ACTION CLOSURE REPORT ...................................................................5-1 6.0 DOCUMENTATION CERTIFICATION .........................................................................6-1 7.0 LIMITATIONS ..............................................................................................................7-1 8.0 REFERENCES .............................................................................................................8-1
  6. Page 67 of 500

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-032 Attachment 55 Page 67 of 4786 Berlin Campus Settling Basin Self-Implementing & Risk-Based Cleanup Plan September 2015 LIST OF FIGURES Figure 1....................................................................................................................... Locus Map Figure 2........................................................................................................ Area Receptors Map Figure 3................................................................................................................ Aerial Site Plan Figure 4...................................................................................................Existing Conditions Plan Figure 5....................................................................................................Sampling Location Plan Figure 6............................................................................. Extent of Contamination: PCBs in Soil Figure 7...................................................................................................... Soil Remediation Plan Figure 8.................................................................. Proposed Cap, ELUR and Fence Boundaries LIST OF TABLES Table 1 ....................................................................................... July 2010 Soil Sampling Results Table 2 ....................................................... December 2011/January 2012 Soil Sampling Results Table 3........................................................ Summary of 2012 Composite Soil Analytical Results Table 3A .................................................................................. 2012 Composite Soil Sample Key Table 4 ..................................................................... Summary of Discrete Soil Analytical Results Table 5 .............................................................. Summary of 2014 & 2015 Soil Analytical Results Table 6........................................................................ July 2015 Groundwater Analytical Results Table 7....................................................... Equipment Rinse and Field Blanks Analytical Results LIST OF APPENDICES Appendix A ............................................................ Screening Level Ecological Risk Assessment Appendix B .................................................................................... Laboratory Analytical Reports Appendix C .............................................................................................................. Certifications
  7. Page 68 of 500

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-032 Attachment 55 Page 68 of 4786 Berlin Campus Settling Basin Self-Implementing & Risk-Based Cleanup Plan September 2015 1.0 INTRODUCTION Weston & Sampson, Inc. (Weston & Sampson) has prepared this Self-Implementing and Risk Based Hybrid Cleanup Plan (Plan)on behalf of Eversource Energy (Eversource), for precharacterization, removal, disposal, and remediation of soil impacted with polychlorinated biphenyls (PCBs) at a storm water settling basin and adjacent upland/wooded area located on Eversource’s Berlin Campus located in Berlin, Connecticut (the Site). Weston & Sampson has recently completed pre-characterization sampling in general accordance with 40 CFR 761.61(a) Subpart N, the Self-Implementing On-Site Cleanup and Disposal of PCB Remediation Waste. Several variations from Subpart N are proposed in this cleanup plan, hence the proposed plan is a hybrid self-implementing (40 CFR 761.61(a)) and a risk-based (40 CFR 761.61(c)) cleanup approach. This report describes the results of the pre-characterization program and serves as the notification and certification of cleanup activities planned for the Site, as required by 40 CFR 761.61, including the following: In accordance with 40 CFR 761.61(a)(3), this Plan contains the following: • (A) – Discussion of the nature and extent of contamination; • (B) – A summary of procedures used to sample impacted areas and associated tables presenting the analytical gathered during the investigation; • (C) – The location and extent of the impacted area with references; • (D) – The cleanup plan, schedule and disposal technologies and approach; and (E) – Written certifications by the property owner and laboratory and subsequent to approval and selection, the remediation contractor. During previous field investigations conducted at the Site by Eversource and Weston & Sampson, as well as the most recent pre-characterization sampling activities associated with the remedial investigation sampling plan, PCBs were detected in site soil as well as sediment in an adjacent stream. Eversource is proposing to remove and dispose of impacted soil at the Site containing PCBs greater than 25 milligrams-per-kilogram (mg/kg) as well as excavating and capping PCB impacted soils with concentrations greater than 10 mg/kg and less than 25 mg/kg. Under the Risk-Based portion of this Plan, soils with PCB concentrations less than 10 mg/kg will remain in place under an Environmental Land Use Restriction (ELUR) with access restricted by a locked, chain-link fence with warning signage. The Plan presented below describes the field and analytical methods for pre-characterization of which are subject to the Toxic Substance Control Act (TSCA) regulations. This approach is more conservative than the self-implementing cleanup standards for lowoccupancy areas (<25 mg/kg per 761.61(a)(4)(i)(B) and includes capping of soils consistent with high occupancy standards 761.61(a)(4)(i)(A). The Site is characterized as a low-occupancy area per 761.3 since individuals are not present in this area for more than 6.7 hours per week or 335 hours per year. Further, the Site is and will continue to be fenced preventing access from Eversource employees, visitors and other individuals. Additionally, since the self-implementing portion of this Plan will be performed in a more conservative manner using the prescribed cleanup levels from the self-implementing approach, a site-specific Human Health Risk Assessment is not required per 761.61(c). As this Plan describes, all soils with PCB concentrations greater than 10 mg/kg will either be emplaced under a cap designed/constructed in accordance with 761.61(a)(7) or disposed off-site. 1.1 Applicability Cleanup at the Site will be limited to soils from interior and exterior portions of the settling basin. No groundwater, surface water, sediments, sewers, sewage treatment systems, private or www.westonandsampson.com 1-1
  8. Page 69 of 500

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-032 Attachment 55 Page 69 of 4786 Berlin Campus Settling Basin Self-Implementing & Risk-Based Cleanup Plan September 2015 public drinking water sources or distribution systems, grazing lands, or vegetable gardens will be part of the Site cleanup. Therefore, the Site meets the applicability criteria necessary for use of the self-implementing procedures, as provided in 40 CFR 761.61(a) Self-Implementing OnSite Cleanup and Disposal of PCB Remediation Waste. However, as described above, this Plan is a hybrid of 761.61(a) and 761.61(c) since variations to the self-implementing procedures are proposed. 1.2 Notifications In addition to submitting this report to the U.S. Environmental Protection Agency (EPA) Region 1 officials, a copy of this report has been provided to the following representatives of State and local agencies, and serves as notification of Eversource’s intent to remediate the Site: Mr. Gary Trombly Connecticut Department of Energy and Environmental Protection Waste Engineering and Enforcement Division PCB Program 79 Elm Street Hartford, CT 06106-5127; and Mr. Paul Hutcheon Director of Health Central Connecticut Health District – Central Office 505 Silas Deane Highway Wethersfield, CT 06109. www.westonandsampson.com 1-2
  9. Page 70 of 500

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-032 Attachment 55 Page 70 of 4786 Berlin Campus Settling Basin Self-Implementing & Risk-Based Cleanup Plan September 2015 2.0 SITE DESCRIPTION The approximate 8,000 square-foot stormwater settling basin and upland/wooded area (the “Site”) is located southeast of the parking garage on Eversource’s Berlin Campus located at 107 Selden Street, Berlin, Connecticut. The location of the Site is shown on Figure 1 (Site Locus Map), sensitive receptors around the Site are shown in Figure 2 (Area Receptors Map), an aerial plan of the Site is shown in Figure 3 (Aerial Site Plan) and the significant Site features are shown in Figure 4 (Existing Conditions Plan). The settling basin receives storm water from two inlets connected to three catch basins located in a paved parking lot located upgradient of the Site and along the southeast side of the parking garage. The Site is surrounded by a parking garage and paved area to the northwest and west, an access road off Deming Road followed by undeveloped wooded land to the north and east, and heavily vegetated/wooded undeveloped land to the south. Topographically, the Site slopes from northwest to southeast and is located within a drainage low situated between topographic highs to the north, east, south, and west of the settling basin. With the exception of the parking garage, a majority of the surrounding land is undeveloped and densely vegetated. Soil at the Site consists of light brown fine to coarse sand in the upper 2.5 feet (ft.) in the vicinity of the two inlets to the settling basin. Subsurface soil in the remainder of the settling basin consists of approximately one (1) foot of dark brown fine sandy silt transitioning to a reddish brown fine sand and clay underlain by up to seven (7) ft. of red-brown sand and fine gravel. Groundwater at the Site is classified by the Connecticut Department of Energy and Environmental Protection (CTDEEP) as GA. The GA classification means that the groundwater is presumed to be suitable for drinking without treatment. Groundwater elevation beneath the Site may be variable throughout the year due to seasonal fluctuation within the basin but was encountered approximately 6 feet below surface grade (bsg). The closest water body is an unnamed stream, located approximately 70 ft. southwest of the outlet from the settling basin. Stormwater overflows from the settling basin into the top of an outlet structure, travels underground in a 36-inch reinforced concrete pipe, then discharges to the unnamed stream referenced above. 2.1 Conceptual Site Model Weston & Sampson was retained by Eversource to evaluate the nature and extent of PCBimpacted soil at the Site for the purposes of remediation of PCB impacted areas. In July 2010, Eversource) conducted pre-characterization of the soil located along the base of the settling basin in support of a project to remove the material that accumulated along the bottom of the settling basin. The soil samples collected as part of the pre-construction characterization indicated the presence of low level PCBs in shallow soils located in the southern and central regions of the settling basin. Based upon these results, additional investigation and sampling was warranted prior to the commencement of remediation/restoration activities, due to the presence of PCBs above regulatory criteria. Additional investigations were conducted by Weston & Sampson from December 2011 through July 2015 and consisted of the advancement of soil borings; the installation of monitoring wells; and the collection and analysis of soil, groundwater, and sediment samples. Based upon the soil and sediment analytical data collected during the additional investigations, PCB-impacted soil (>1 mg/kg) was identified in both the interior and exterior portions of the settling basin. The vertical extent of PCB impacts have been defined to five feet below grade or less in most areas of the Site, with the exception of two areas where PCB impacts extend to 6 to 7 ft. below grade. Low level PCB concentrations were detected in select sediment sample www.westonandsampson.com 2-1
  10. Page 71 of 500

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-032 Attachment 55 Page 71 of 4786 Berlin Campus Settling Basin Self-Implementing & Risk-Based Cleanup Plan September 2015 locations collected from the unnamed stream adjacent to the settling pond. PCB impacts to sediments were assessed and addressed via a Screening Level Ecological Risk Assessment (SLERA) completed by Anchor QEA and Weston & Sampson, the results of which determined that no risk is present relative to the PCB concentrations detected in sediment. A copy of the SLERA is included in Appendix A. Six groundwater monitoring wells were installed in July 2015 at locations both inside and outside the settling basin, as well as at upgradient and downgradient locations. The groundwater analytical results indicate that groundwater has not been impacted by PCBs at the Site. The groundwater table in the settling basin area appears to somewhat variable, as groundwater was not present in monitoring well MW-4 (northeast corner of the basin area). The conceptual site model presents two possible release mechanisms for PCBs at the Site. 1. Based upon a historic aerial photograph dated August 21, 1969 and interviews with knowledgeable Eversource staff, this location on the Berlin campus was historically utilized as a line training area. The training area may have utilized PCB oil-containing equipment which could have potentially released PCBs to the environment. It is plausible that the PCB impacts discovered upon Eversource’s characterization event and subsequent Weston & Sampson sampling events were remnants from previously impacted soils from releases associated with the training area. It is also possible that the distribution of PCB impacts, particularly outside the basin, are a result of previously impacted soils being manipulated and/or redistributed during the construction of the basin and/or PCB-impacted soil from other areas used to construct and/or grade the hillside and other impacted portions of the Site. 2. Another potential release mechanism for PCBs to the environment involves the migration of PCB-impacted fine-grained sediment or PCB containing oils originating from the upgradient equipment storage area to the above-referenced catch basins. PCBimpacted soil outside the perimeter of the settling basin may likely be a result of periodic flooding or overflow of the settling basin. However, this scenario is unlikely given the random distribution and severity of PCB impacts located at the Site and the fact that PCBs were not identified in catch basin sediments. Due to the random distribution and severity of PCB impacts located at the Site and the fact that PCBs were not identified in catch basin sediments, the second scenario is considerably unlikely. Therefore, PCB impacts at the Site are most likely attributed to the historic use of this area as a line training area that resulted in PCB impacts from the manipulation and/or redistribution of the impacted soils during the construction of the basin and other construction or earth-moving activities in this area of the property. Based upon our understanding of the Site, exposure routes for PCBs at the site consist of trespassers, construction workers and Eversource employees coming in direct contact with soil or soil-derived dust. Groundwater has not been and is not expected to become, impacted by PCBs. Sediment, although exhibiting randomly distributed very low concentrations of PCBs, has been determined through a screening level ecological risk assessment to not be a source for PCB exposure. Based upon comments received from CTDEEP on the SLERA, ecological risk to receptors is negligible and no further study is needed. www.westonandsampson.com 2-2

Text of RSR-032 Attachment 54.pdf

Extracted from the file · 121 pages · 447,477 characters

Text of RSR-032 Attachment 53.pdf

Extracted from the file · 204 pages · 625,248 characters

Text of RSR-032 Attachment 52.pdf

Extracted from the file · 130 pages · 298,641 characters

Text of RSR-032 Attachment 51.pdf

Extracted from the file · 57 pages · 123,610 characters

Text of RSR-032 Attachment 50.pdf

Extracted from the file · 6 pages · 8,050 characters

Text of RSR-032 Attachment 49.pdf

Extracted from the file · 83 pages · 194,182 characters

Text of RSR-032 Attachment 48.pdf

Extracted from the file · 3 pages · 8,556 characters

Text of RSR-032 Attachment 47.pdf

Extracted from the file · 10 pages · 14,266 characters

Text of RSR-032 Attachment 46.pdf

Extracted from the file · 7 pages · 10,783 characters

Text of RSR-032 Attachment 45.pdf

Extracted from the file · 373 pages · 490,688 characters

Text of RSR-032 Attachment 44.pdf

Extracted from the file · 38 pages · 6,799 characters

Text of RSR-032 Attachment 43.pdf

Extracted from the file · 49 pages · 83,514 characters

Text of RSR-032 Attachment 42.pdf

Extracted from the file · 25 pages, 14 without text · 13,836 characters

Text of RSR-032 Attachment 41.pdf

Extracted from the file · 3 pages · 5,506 characters

Text of RSR-032 Attachment 40.pdf

Extracted from the file · 1 page · 1,448 characters

Text of RSR-032 Attachment 39.pdf

Extracted from the file · 14 pages · 17,145 characters

Text of RSR-032 Attachment 38.pdf

Extracted from the file · 12 pages · 14,555 characters

Text of RSR-032 Attachment 37.pdf

Extracted from the file · 12 pages · 14,398 characters

Text of RSR-032 Attachment 36.pdf

Extracted from the file · 12 pages · 15,426 characters

Text of RSR-032 Attachment 35.pdf

Extracted from the file · 38 pages · 61,388 characters

Text of RSR-032 Attachment 34.pdf

Extracted from the file · 13 pages · 12,161 characters

Text of RSR-032 Attachment 33.pdf

Extracted from the file · 11 pages · 7,928 characters

Text of RSR-032 Attachment 32.pdf

Extracted from the file · 3 pages · 444 characters

Text of RSR-032 Attachment 31.pdf

Extracted from the file · 26 pages · 3,891 characters

Text of RSR-032 Attachment 30.pdf

Extracted from the file · 18 pages · 2,691 characters

Text of RSR-032 Attachment 29.pdf

Extracted from the file · 9 pages · 10,238 characters

Text of RSR-032 Attachment 28.pdf

Extracted from the file · 127 pages · 218,825 characters

Text of RSR-032 Attachment 27.pdf

Extracted from the file · 12 pages · 12,858 characters

Text of RSR-032 Attachment 26.pdf

Extracted from the file · 12 pages · 14,742 characters

Text of RSR-032 Attachment 25.pdf

Extracted from the file · 14 pages · 16,968 characters

Text of RSR-032 Attachment 24.pdf

Extracted from the file · 13 pages · 16,061 characters

Text of RSR-032 Attachment 23.pdf

Extracted from the file · 19 pages · 8,357 characters

Text of RSR-032 Attachment 22.pdf

Extracted from the file · 1,282 pages · 3,304,505 characters

Text of RSR-032 Attachment 21.pdf

Extracted from the file · 1,005 pages · 2,609,640 characters

Text of RSR-032 Attachment 20_Part2.pdf

Extracted from the file · 109 pages · 16,568 characters

Text of RSR-032 Attachment 20_Part1.pdf

Extracted from the file · 150 pages · 190,904 characters

Text of RSR-032 Attachment 19.pdf

Extracted from the file · 23 pages · 39,103 characters

Text of RSR-032 Attachment 18.pdf

Extracted from the file · 8 pages · 12,671 characters

Text of RSR-032 Attachment 17_Part3.pdf

Extracted from the file · 282 pages · 740,441 characters

Text of RSR-032 Attachment 17_Part2.pdf

Extracted from the file · 500 pages · 1,293,274 characters

Text of RSR-032 Attachment 17_Part1.pdf

Extracted from the file · 500 pages · 1,270,790 characters

Text of RSR-032 Attachment 16.pdf

Extracted from the file · 46 pages · 130,280 characters

Text of RSR-032 Attachment 15.pdf

Extracted from the file · 17 pages · 25,967 characters

Text of RSR-032 Attachment 14.pdf

Extracted from the file · 10 pages · 15,944 characters

Text of RSR-032 Attachment 13.pdf

Extracted from the file · 17 pages · 29,849 characters

Text of RSR-032 Attachment 12.pdf

Extracted from the file · 12 pages · 20,731 characters

Text of RSR-032 Attachment 11.pdf

Extracted from the file · 15 pages · 23,899 characters

Text of RSR-032 Attachment 10.pdf

Extracted from the file · 145 pages · 332,684 characters

Text of RSR-032 Attachment 9.pdf

Extracted from the file · 897 pages · 1,943,866 characters

Text of RSR-032 Attachment 8.pdf

Extracted from the file · 203 pages · 512,054 characters

Text of RSR-032 Attachment 7.pdf

Extracted from the file · 12 pages · 13,977 characters

Text of RSR-032 Attachment 6.pdf

Extracted from the file · 335 pages · 685,056 characters

Text of RSR-032 Attachment 5.pdf

Extracted from the file · 65 pages · 194,221 characters

Text of RSR-032 Attachment 4.pdf

Extracted from the file · 570 pages · 1,357,502 characters

Text of RSR-032 Attachment 3.pdf

Extracted from the file · 8 pages · 15,762 characters

Text of RSR-032 Attachment 2.pdf

Extracted from the file · 26 pages · 3,865 characters

Text of RSR-032 Attachment 1.pdf

Extracted from the file · 18 pages · 2,673 characters

As listed on the current system

Question(s) Answered 32 (Connecticut Light and Power Company dba Eversource Energy) Date Filed: 10/30/2026

This filing on the current system (opens in a new tab)