Skip to main content

A prototype public docket site for the Connecticut Public Utilities Regulatory Authority

Utility Dockets and Filings

Interrogatory responses

Answers to questions 32

ResponseFiled by Connecticut Light and Power Company dba Eversource Energy210 files
Part of docket 26-05-10Open
  • Electric
Application of The Connecticut Light and Power Company d/b/a Eversource Energy to Amend its Rate Schedules

Files210

Search terms highlighted
Eversource rate increase is on 9 pages across 3 files of the text below, highlighted. Go to the first matchClear highlighting
Words on different pages
Words on different pages
Words on different pages

Text of RSR-032 Attachment 176_Part2.pdf

Extracted from the file · 754 pages · 1,598,897 characters

Text of RSR-032 Attachment 176_Part1.pdf

Extracted from the file · 110 pages · 439,601 characters

Text of RSR-032 Attachment 175_Part7.pdf

Extracted from the file · 275 pages · 622,526 characters

Text of RSR-032 Attachment 175_Part6.pdf

Extracted from the file · 350 pages · 828,421 characters

Text of RSR-032 Attachment 175_Part5.pdf

Extracted from the file · 350 pages · 841,526 characters

Text of RSR-032 Attachment 175_Part4.pdf

Extracted from the file · 350 pages · 529,828 characters

Text of RSR-032 Attachment 175_Part3.pdf

Extracted from the file · 350 pages · 417,827 characters

Text of RSR-032 Attachment 175_Part2.pdf

Extracted from the file · 350 pages · 717,402 characters

Text of RSR-032 Attachment 175_Part1.pdf

Extracted from the file · 350 pages · 426,888 characters

Text of RSR-032 Attachment 174.pdf

Extracted from the file · 2 pages · 3,788 characters

Text of RSR-032 Attachment 173.pdf

Extracted from the file · 9 pages · 19,276 characters

Text of RSR-032 Attachment 172.pdf

Extracted from the file · 2 pages · 5,216 characters

Text of RSR-032 Attachment 171.pdf

Extracted from the file · 2 pages · 7,025 characters

Text of RSR-032 Attachment 170.pdf

Extracted from the file · 4 pages · 596 characters

Text of RSR-032 Attachment 169.pdf

Extracted from the file · 14 pages · 2,105 characters

Text of RSR-032 Attachment 168.pdf

Extracted from the file · 178 pages · 303,260 characters

Text of RSR-032 Attachment 167_Part2.pdf

Extracted from the file · 844 pages · 1,367,165 characters

Text of RSR-032 Attachment 167_Part1.pdf

Extracted from the file · 284 pages · 480,797 characters

Text of RSR-032 Attachment 166.pdf

Extracted from the file · 4 pages · 5,984 characters

Text of RSR-032 Attachment 165_Part 4.pdf

Extracted from the file · 84 pages · 130,960 characters

Text of RSR-032 Attachment 165_Part 3.pdf

Extracted from the file · 482 pages · 674,897 characters

Text of RSR-032 Attachment 165_Part 2.pdf

Extracted from the file · 509 pages · 549,394 characters

Text of RSR-032 Attachment 165_Part 1.pdf

Extracted from the file · 500 pages · 578,799 characters

Text of RSR-032 Attachment 164.pdf

Extracted from the file · 42 pages, 16 without text · 66,266 characters

Text of RSR-032 Attachment 163.pdf

Extracted from the file · 575 pages · 624,136 characters

Text of RSR-032 Attachment 162.pdf

Extracted from the file · 17 pages · 19,879 characters

Text of RSR-032 Attachment 161 _Part2.pdf

Extracted from the file · 609 pages · 625,572 characters

Text of RSR-032 Attachment 161 _Part1.pdf

Extracted from the file · 131 pages · 171,359 characters

Text of RSR-032 Attachment 160.pdf

Extracted from the file · 56 pages · 84,793 characters

Text of RSR-032 Attachment 159.pdf

Extracted from the file · 97 pages · 159,126 characters

Text of RSR-032 Attachment 158.pdf

Extracted from the file · 54 pages · 96,528 characters

Text of RSR-032 Attachment 157.pdf

Extracted from the file · 261 pages · 326,004 characters

Text of RSR-032 Attachment 156.pdf

Extracted from the file · 74 pages · 99,158 characters

Text of RSR-032 Attachment 155.pdf

Extracted from the file · 40 pages · 40,141 characters

Text of RSR-032 Attachment 154.pdf

Extracted from the file · 37 pages · 59,275 characters

Text of RSR-032 Attachment 153.pdf

Extracted from the file · 61 pages · 86,468 characters

Text of RSR-032 Attachment 152.pdf

Extracted from the file · 126 pages · 258,689 characters

Text of RSR-032 Attachment 151.pdf

Extracted from the file · 340 pages · 405,994 characters

Text of RSR-032 Attachment 150.pdf

Extracted from the file · 33 pages · 27,344 characters

Text of RSR-032 Attachment 149.pdf

Extracted from the file · 47 pages · 51,678 characters

Text of RSR-032 Attachment 148.pdf

Extracted from the file · 52 pages · 65,933 characters

Text of RSR-032 Attachment 147.pdf

Extracted from the file · 136 pages · 187,807 characters

Text of RSR-032 Attachment 146.pdf

Extracted from the file · 211 pages · 257,714 characters

Text of RSR-032 Attachment 145.pdf

Extracted from the file · 58 pages · 84,698 characters

Text of RSR-032 Attachment 144.pdf

Extracted from the file · 31 pages · 57,751 characters

Text of RSR-032 Attachment 143.pdf

Extracted from the file · 30 pages · 51,258 characters

Text of RSR-032 Attachment 142.pdf

Extracted from the file · 33 pages · 29,732 characters

Text of RSR-032 Attachment 141.pdf

Extracted from the file · 578 pages · 899,265 characters

Text of RSR-032 Attachment 140.pdf

Extracted from the file · 26 pages · 45,518 characters

Text of RSR-032 Attachment 139.pdf

Extracted from the file · 29 pages · 58,671 characters

Text of RSR-032 Attachment 138.pdf

Extracted from the file · 24 pages · 44,766 characters

Text of RSR-032 Attachment 137.pdf

Extracted from the file · 54 pages · 85,922 characters

Text of RSR-032 Attachment 136.pdf

Extracted from the file · 618 pages · 1,036,591 characters

Text of RSR-032 Attachment 135.pdf

Extracted from the file · 52 pages · 107,952 characters

Text of RSR-032 Attachment 134.pdf

Extracted from the file · 57 pages · 119,843 characters

Text of RSR-032 Attachment 133.pdf

Extracted from the file · 82 pages · 196,725 characters

Text of RSR-032 Attachment 132.pdf

Extracted from the file · 137 pages · 251,594 characters

Text of RSR-032 Attachment 131.pdf

Extracted from the file · 7 pages · 1,043 characters

Text of RSR-032 Attachment 130.pdf

Extracted from the file · 847 pages · 1,478,588 characters

Text of RSR-032 Attachment 129.pdf

Extracted from the file · 124 pages · 255,121 characters

Text of RSR-032 Attachment 128.pdf

Extracted from the file · 104 pages · 208,223 characters

Text of RSR-032 Attachment 127.pdf

Extracted from the file · 125 pages · 243,340 characters

Text of RSR-032 Attachment 126.pdf

Extracted from the file · 128 pages · 264,919 characters

Text of RSR-032 Attachment 125.pdf

Extracted from the file · 824 pages · 1,180,085 characters

Text of RSR-032 Attachment 124.pdf

Extracted from the file · 28 pages · 47,835 characters

Text of RSR-032 Attachment 123.pdf

Extracted from the file · 29 pages · 4,370 characters

Text of RSR-032 Attachment 122.pdf

Extracted from the file · 29 pages · 4,370 characters

Text of RSR-032 Attachment 121.pdf

Extracted from the file · 50 pages · 7,541 characters

Text of RSR-032 Attachment 120.PDF

Extracted from the file · 2 pages · 3,192 characters

Text of RSR-032 Attachment 119_Part3.pdf

Extracted from the file · 105 pages · 238,387 characters

Text of RSR-032 Attachment 119_Part2.pdf

Extracted from the file · 169 pages · 372,755 characters

Text of RSR-032 Attachment 119_Part1.pdf

Extracted from the file · 51 pages · 61,331 characters

Text of RSR-032 Attachment 118_Part6.pdf

Extracted from the file · 54 pages · 47,246 characters

Text of RSR-032 Attachment 118_Part5.pdf

Extracted from the file · 254 pages · 39,246 characters

Text of RSR-032 Attachment 118_Part4.pdf

Extracted from the file · 378 pages · 97,273 characters

Text of RSR-032 Attachment 118_Part3.pdf

Extracted from the file · 218 pages · 519,182 characters

Text of RSR-032 Attachment 118_Part2.pdf

Extracted from the file · 334 pages · 879,939 characters

Text of RSR-032 Attachment 118_Part1.pdf

Extracted from the file · 164 pages · 353,286 characters

Text of RSR-032 Attachment 117.pdf

Extracted from the file · 55 pages · 49,861 characters

Text of RSR-032 Attachment 116.pdf

Extracted from the file · 2 pages · 5,651 characters

Text of RSR-032 Attachment 115.pdf

Extracted from the file · 135 pages · 191,165 characters

Text of RSR-032 Attachment 114.pdf

Extracted from the file · 123 pages · 185,862 characters

Text of RSR-032 Attachment 113.pdf

Extracted from the file · 4 pages · 596 characters

Text of RSR-032 Attachment 112.pdf

Extracted from the file · 2 pages · 298 characters

Text of RSR-032 Attachment 111.pdf

Extracted from the file · 42 pages · 123,247 characters

Text of RSR-032 Attachment 110.pdf

Extracted from the file · 38 pages · 8,159 characters

Text of RSR-032 Attachment 109.pdf

Extracted from the file · 1 page · 149 characters

Text of RSR-032 Attachment 108.pdf

Extracted from the file · 23 pages · 27,882 characters

Text of RSR-032 Attachment 107.pdf

Extracted from the file · 1 page · 243 characters

Text of RSR-032 Attachment 106.pdf

Extracted from the file · 1 page · 321 characters

Text of RSR-032 Attachment 105.pdf

Extracted from the file · 493 pages · 1,262,208 characters

Text of RSR-032 Attachment 104.pdf

Extracted from the file · 628 pages · 1,570,354 characters

Text of RSR-032 Attachment 103.pdf

Extracted from the file · 40 pages · 129,345 characters

Text of RSR-032 Attachment 102.pdf

Extracted from the file · 2 pages · 298 characters

Text of RSR-032 Attachment 101.pdf

Extracted from the file · 186 pages · 437,630 characters

Text of RSR-032 Attachment 100.pdf

Extracted from the file · 244 pages · 509,938 characters

Text of RSR-032 Attachment 99.pdf

Extracted from the file · 193 pages · 412,257 characters

Text of RSR-032 Attachment 98.pdf

Extracted from the file · 2,201 pages · 3,529,384 characters

Text of RSR-032 Attachment 97.pdf

Extracted from the file · 2 pages · 2,870 characters

Text of RSR-032 Attachment 96.pdf

Extracted from the file · 2 pages · 296 characters

Text of RSR-032 Attachment 95.pdf

Extracted from the file · 27 pages · 8,963 characters

Text of RSR-032 Attachment 94.pdf

Extracted from the file · 3 pages · 5,367 characters

Text of RSR-032 Attachment 93.pdf

Extracted from the file · 3 pages · 5,315 characters

Text of RSR-032 Attachment 92.pdf

Extracted from the file · 3 pages · 5,225 characters

Text of RSR-032 Attachment 91.pdf

Extracted from the file · 2 pages · 2,709 characters

Text of RSR-032 Attachment 90.pdf

Extracted from the file · 2 pages · 2,630 characters

Text of RSR-032 Attachment 89.pdf

Extracted from the file · 2 pages · 2,615 characters

Text of RSR-032 Attachment 88.pdf

Extracted from the file · 2 pages · 2,771 characters

Text of RSR-032 Attachment 87.pdf

Extracted from the file · 2 pages · 2,948 characters

Text of RSR-032 Attachment 86.pdf

Extracted from the file · 2 pages · 2,772 characters

Text of RSR-032 Attachment 85.pdf

Extracted from the file · 2 pages · 2,764 characters

Text of RSR-032 Attachment 84.pdf

Extracted from the file · 2 pages · 2,999 characters

Text of RSR-032 Attachment 83.pdf

Extracted from the file · 2 pages · 2,995 characters

Text of RSR-032 Attachment 82.pdf

Extracted from the file · 2 pages · 2,968 characters

Text of RSR-032 Attachment 81.pdf

Extracted from the file · 2 pages · 2,973 characters

Text of RSR-032 Attachment 80.pdf

Extracted from the file · 2 pages · 296 characters

Text of RSR-032 Attachment 79.pdf

Extracted from the file · 2 pages · 2,694 characters

Text of RSR-032 Attachment 78.pdf

Extracted from the file · 3 pages · 3,876 characters

Text of RSR-032 Attachment 77.pdf

Extracted from the file · 3 pages · 3,646 characters

Text of RSR-032 Attachment 76.pdf

Extracted from the file · 3 pages · 3,805 characters

Text of RSR-032 Attachment 75.pdf

Extracted from the file · 9 pages · 13,840 characters

Text of RSR-032 Attachment 74.pdf

Extracted from the file · 3 pages · 3,990 characters

Text of RSR-032 Attachment 73.pdf

Extracted from the file · 3 pages · 4,170 characters

Text of RSR-032 Attachment 72.pdf

Extracted from the file · 3 pages · 3,957 characters

Text of RSR-032 Attachment 71.pdf

Extracted from the file · 3 pages · 3,642 characters

Text of RSR-032 Attachment 70.pdf

Extracted from the file · 2 pages · 2,078 characters

Text of RSR-032 Attachment 69.pdf

Extracted from the file · 3 pages · 4,357 characters

Text of RSR-032 Attachment 68.pdf

Extracted from the file · 3 pages · 3,165 characters

Text of RSR-032 Attachment 67.pdf

Extracted from the file · 4 pages · 3,715 characters

Text of RSR-032 Attachment 66.pdf

Extracted from the file · 3 pages · 3,168 characters

Text of RSR-032 Attachment 65.pdf

Extracted from the file · 3 pages · 444 characters

Text of RSR-032 Attachment 64.pdf

Extracted from the file · 2 pages · 2,099 characters

Text of RSR-032 Attachment 63.pdf

Extracted from the file · 2 pages · 2,062 characters

Text of RSR-032 Attachment 62.pdf

Extracted from the file · 7 pages · 5,200 characters

Text of RSR-032 Attachment 61.pdf

Extracted from the file · 5 pages · 10,643 characters

Text of RSR-032 Attachment 60.pdf

Extracted from the file · 2 pages · 296 characters

Text of RSR-032 Attachment 59.pdf

Extracted from the file · 2 pages · 4,147 characters

Text of RSR-032 Attachment 58.pdf

Extracted from the file · 1 page · 2,448 characters

Text of RSR-032 Attachment 57.pdf

Extracted from the file · 2 pages · 296 characters

Text of RSR-032 Attachment 56.pdf

Extracted from the file · 10 pages · 1,491 characters

Text of RSR-032 Attachment 55_Part10.pdf

Extracted from the file · 286 pages · 344,076 characters

Text of RSR-032 Attachment 55_Part9.pdf

Extracted from the file · 500 pages · 957,292 characters

Text of RSR-032 Attachment 55_Part8.pdf

Extracted from the file · 500 pages · 874,750 characters

Text of RSR-032 Attachment 55_Part7.pdf

Extracted from the file · 500 pages · 470,022 characters

Text of RSR-032 Attachment 55_Part6.pdf

Extracted from the file · 500 pages · 494,317 characters

Text of RSR-032 Attachment 55_Part5.pdf

Extracted from the file · 500 pages · 461,760 characters

Text of RSR-032 Attachment 55_Part4.pdf

Extracted from the file · 500 pages · 492,694 characters

Text of RSR-032 Attachment 55_Part3.pdf

Extracted from the file · 500 pages · 580,603 characters

Text of RSR-032 Attachment 55_Part2.pdf

Extracted from the file · 500 pages · 483,371 characters

Text of RSR-032 Attachment 55_Part1.pdf

Extracted from the file · 500 pages · 881,595 characters

Text of RSR-032 Attachment 54.pdf

Extracted from the file · 121 pages · 447,477 characters

Text of RSR-032 Attachment 53.pdf

Extracted from the file · 204 pages · 625,248 characters

Text of RSR-032 Attachment 52.pdf

Extracted from the file · 130 pages · 298,641 characters

Text of RSR-032 Attachment 51.pdf

Extracted from the file · 57 pages · 123,610 characters

Text of RSR-032 Attachment 50.pdf

Extracted from the file · 6 pages · 8,050 characters

Text of RSR-032 Attachment 49.pdf

Extracted from the file · 83 pages · 194,182 characters

Text of RSR-032 Attachment 48.pdf

Extracted from the file · 3 pages · 8,556 characters

Text of RSR-032 Attachment 47.pdf

Extracted from the file · 10 pages · 14,266 characters

Text of RSR-032 Attachment 46.pdf

Extracted from the file · 7 pages · 10,783 characters

Text of RSR-032 Attachment 45.pdf

Extracted from the file · 373 pages · 490,688 characters

Text of RSR-032 Attachment 44.pdf

Extracted from the file · 38 pages · 6,799 characters

Text of RSR-032 Attachment 43.pdf

Extracted from the file · 49 pages · 83,514 characters

Text of RSR-032 Attachment 42.pdf

Extracted from the file · 25 pages, 14 without text · 13,836 characters

Text of RSR-032 Attachment 41.pdf

Extracted from the file · 3 pages · 5,506 characters

Text of RSR-032 Attachment 40.pdf

Extracted from the file · 1 page · 1,448 characters

Text of RSR-032 Attachment 39.pdf

Extracted from the file · 14 pages · 17,145 characters

Text of RSR-032 Attachment 38.pdf

Extracted from the file · 12 pages · 14,555 characters

Text of RSR-032 Attachment 37.pdf

Extracted from the file · 12 pages · 14,398 characters

Text of RSR-032 Attachment 36.pdf

Extracted from the file · 12 pages · 15,426 characters

Text of RSR-032 Attachment 35.pdf

Extracted from the file · 38 pages · 61,388 characters

Text of RSR-032 Attachment 34.pdf

Extracted from the file · 13 pages · 12,161 characters

Text of RSR-032 Attachment 33.pdf

Extracted from the file · 11 pages · 7,928 characters

Text of RSR-032 Attachment 32.pdf

Extracted from the file · 3 pages · 444 characters

Text of RSR-032 Attachment 31.pdf

Extracted from the file · 26 pages · 3,891 characters

Text of RSR-032 Attachment 30.pdf

Extracted from the file · 18 pages · 2,691 characters

Text of RSR-032 Attachment 29.pdf

Extracted from the file · 9 pages · 10,238 characters

Text of RSR-032 Attachment 28.pdf

Extracted from the file · 127 pages · 218,825 characters

Text of RSR-032 Attachment 27.pdf

Extracted from the file · 12 pages · 12,858 characters

Text of RSR-032 Attachment 26.pdf

Extracted from the file · 12 pages · 14,742 characters

Text of RSR-032 Attachment 25.pdf

Extracted from the file · 14 pages · 16,968 characters

Text of RSR-032 Attachment 24.pdf

Extracted from the file · 13 pages · 16,061 characters

Text of RSR-032 Attachment 23.pdf

Extracted from the file · 19 pages · 8,357 characters

Text of RSR-032 Attachment 22.pdf

Extracted from the file · 1,282 pages · 3,304,505 characters

Text of RSR-032 Attachment 21.pdf

Extracted from the file · 1,005 pages · 2,609,640 characters

Text of RSR-032 Attachment 20_Part2.pdf

Extracted from the file · 109 pages · 16,568 characters

Text of RSR-032 Attachment 20_Part1.pdf

Extracted from the file · 150 pages · 190,904 characters

Text of RSR-032 Attachment 19.pdf

Extracted from the file · 23 pages · 39,103 characters

Text of RSR-032 Attachment 18.pdf

Extracted from the file · 8 pages · 12,671 characters

Text of RSR-032 Attachment 17_Part3.pdf

Extracted from the file · 282 pages · 740,441 characters

Text of RSR-032 Attachment 17_Part2.pdf

Extracted from the file · 500 pages · 1,293,274 characters

Text of RSR-032 Attachment 17_Part1.pdf

Extracted from the file · 500 pages · 1,270,790 characters

Text of RSR-032 Attachment 16.pdf

Extracted from the file · 46 pages · 130,280 characters

Text of RSR-032 Attachment 15.pdf

Extracted from the file · 17 pages · 25,967 characters

Text of RSR-032 Attachment 14.pdf

Extracted from the file · 10 pages · 15,944 characters

Text of RSR-032 Attachment 13.pdf

Extracted from the file · 17 pages · 29,849 characters

Text of RSR-032 Attachment 12.pdf

Extracted from the file · 12 pages · 20,731 characters

Text of RSR-032 Attachment 11.pdf

Extracted from the file · 15 pages · 23,899 characters

Text of RSR-032 Attachment 10.pdf

Extracted from the file · 145 pages · 332,684 characters

Text of RSR-032 Attachment 9.pdf

Extracted from the file · 897 pages · 1,943,866 characters

Words on different pages
  1. Page 41 of 203

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-032 Attachment 8 Page 41 of 203 TABLE 1 Areas Of Concern (AOCs)/ Site Conceptual (CSM) Summary Rockville Former MGP Site 13 Maple Street and Off-site Areas of Investigation Rockville, Vernon, CT AOC # 20 21 22 AOC Description Off-site Tar Impacts (Residence #14 Maple Street) Off-site Surface Soils Maple Street School [PAHs Detected above RSR Criteria] Off-site Surface Soils 175 Union Street [PAHs Detected above RSR Criteria] Table-1 AOC Summary.xlsx COCs VOCs (BTEX), SVOCs, Total Cyanide, ETPH PAHs PAHs Possible Release Mechanisms and Migration Pathways Tar-impacted soils (sheen and odor) between 30 and 37 feet. Tar migrated beneath Maple Avenue onto the western portion of the property. PAHs detected in surface soils and shallow subsurface soils at the Maple Street School property. PAHs are detected in surface soils at nearby off-site properties (175 Union Street and Tolland AWC) Potentially Affected Media Subsurface soils Groundwater Surface soils Surface soils Previous Investigation Soil Locations TB-207, TB-210, TB-211, TB-215, MW-15D R453, R454, R455, R456 R501-A, R-501-B, R-501-C, R-501-D R502-A, R-502-B, R-502-C, R-502-D R503-A, R-503-B, R-503-C, R-503-D R504-A, R-504-B, R-504-C, R-504-D R505-A, R-505-B, R-505-C, R-505-D R506-A, R-506-B, R-506-C, R-506-D R426-A,R426B,R426-C, R426-D R437-A,R437B,R437-C, R437-D R438-A,R438B,R438-C, R438-D R446-A,R446B,R446-C, R446-D R452-A,R452B,R452-C, R452-D RBG2-B and RBG2-C Phase III Soil Locations Not investigated during Phase III Previous Investigation Groundwater Locations MW-15S MW-15D Phase III Investigation Groundwater Locations Previous COCs in Soil MW-23S Subsurface soils contained detections of VOCs and PAHs at concentrations above the GB PMC. However, these impacts are likely below the water table and the GB PMC is not applicable. Not investigated during Phase III Phase III COCs in Soil Previous COCs in Groundwater MW-15S: Metals and cyanide exceeded SWPC. VOC (MTBE detected). MW-15D: Metals detected above the SWPC. Phase III COCs in Groundwater COCs in Surface Water Investigation Status Shallow: Adjacent USPS ROW: MW-23S: VOC (chloroform) and metals detected below SWPC Hockanum River located up gradient of location. Phase II (off-site) 1994 Phase III Investigation (2018) Remediation Status Access to property was not provided. Tar impacts were assessed with a soil boring within Maple Street ROW (AOC-17) Remedial evaluation pending the completion of the Phase III investigation. Not investigated during Phase III Groundwater not investigated Groundwater not investigated Surface soils and shallow subsurface soils Not investigated during Phase III Groundwater not tested. Groundwater not tested. Hockanum River located up gradient of location. Phase II- Surface Soil collection in 1995 Possible historic fill associated with the development of the school property or potential off-site source. Not investigated during Phase III Groundwater not investigated Groundwater not investigated Surface soils and shallow subsurface soils Not investigated during Phase III Groundwater not tested. Groundwater not tested. Hockanum River located up gradient of location. Phase II- Surface Soil collection in 1995 Possible historic fill associated with the development of the property or potential offsite source. Page 9 of 10
  2. Page 42 of 203

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-032 Attachment 8 Page 42 of 203 TABLE 1 Areas Of Concern (AOCs)/ Site Conceptual (CSM) Summary Rockville Former MGP Site 13 Maple Street and Off-site Areas of Investigation Rockville, Vernon, CT AOC # AOC Description COCs Possible Release Mechanisms and Migration Pathways Potentially Affected Media Previous Investigation Soil Locations Phase III Soil Locations Previous Investigation Groundwater Locations Phase III Investigation Groundwater Locations Previous COCs in Soil Phase III COCs in Soil Previous COCs in Groundwater Phase III COCs in Groundwater COCs in Surface Water Investigation Status Remediation Status Phase II (off-site) 1994 Phase III ESA (2018-2020) Additional Phase III ESA investigation is proposed to assess seasonal groundwater conditions at St. Joseph's Church property and to assess the nature and extent west of groundwater impacts to the west of West Street. Shallow: Tar globules / staining in MW-20S. MW-19S/MW-21S/MW-28S: metal and PAHs detected MW-13S and MW-26S (Plasticizers detected -possible lab contamination) MW-27S: ETPH, metals, and naphthalene detected MW-23S: Metals detected MW-14S: Cyanide, metals, and PAHs detected MW-31S: Barium and nickel detected MW-29S: ETPH and benzene above SWPC and RES & I/C VC. Benzene and ETPH in compliance with the RES VC via soil vapor testing. Naphthalene above SWPC. 23 Off-site Groundwater Impacts VOCs Groundwater impacts from spills or leaks occurring at the site and migrating offsite. Groundwater NA See AOC 16 MW-13S, MW-13D, MW-14S, MW-14D, MW-19S, MW-20S, MW-21S, MW-23S, MW-26S, MW-26D, MW-26BR, MWMW-13S, MW-13D, 27S, MW-28S, MWMW-14S, MW-14D, 30S, MW-31S, MWMW-15S, MW-15D, 40S, MW-41S, MWMW-19S, MW-20S, 42M, MW-42M, MW-21S, MW-23S MW-43S, MW-43M Soils not assessed See AOC 16 Soil Vapor Assessment SV-01, SV-02, SV03, SV-05 MW-41S: ETPH was detected above SWPC and RES & I/C VC. ETPH is in compliance with the RES VC via soil vapor testing. Acenaphthylene above SWPC. PAHs, metals, and VOCs detected MW-42S: VOCs and ETPH not detected. Phenanthrene, barium, and Shallow: Metals and Hockanum River chromium detected. cyanide detected above is located MW-43S: VOCs and ETPH not SWPC. VOCs and PAHs upgradient on-site detected. Phenanthrene and barium detected and detected. MW-26S: ETPH , VOCs and PAHs not approximately Deep: Metals detected 275 feet to 400 detected. Barium detected. above SWPC. VOCs and feet to the west. PAHs detected Intermediate: MW-14M: ETPH above SWPC . Elevated concentrations of benzene and tar-related VOC detected. Acenaphthylene above SWPC. MW-42M: ETPH above GWPC and SWPC, Benzene above GWPC. PAHs, tar -related VOCs, metals (barium, thallium, zinc). detected MW-43M: VOCs, PAHs and ETPH not detected. Barium, nickel, and zinc detected. Deep: MW-14D: metals and VOCs detected. ETPH, Cyanide, and PAHs detected above the SWPC. MW-26D metals and tar-related VOCs detected, PAH (acenaphthylene) detected above SWPC. ETPH not detected Bedrock: MW-26BR Naphthalene and barium detected. VOCs and ETPH not detected. NOTES: MGP=- manufactured gas plant VOC = Volatile Organic Compound BTEX- Benzene, toluene, ethyl benzene and xylenes ETPH- Extractable Total Petroleum Hydrocarbons PAH = Polycyclic Aromatic Hydrocarbon TPH = Total Petroleum Hydrocarbons PCBs= Polychlorinated Biphenyls SWPC- Surface Water Protection Criteria Res DEC- Residential Direct Exposure Criteria I/C DEC - Industrial Commercial Direct Exposure Criteria CSM = Conceptual site model, described by the Connecticut Department of Environmental Protection as "a representation of an environmental system that is used as a tool for understanding and for explaining to others the basis and rationale for site investigation and the conclusions drawn about the environmental conditions at a site. A CSM describes, explains, and provides and understanding of the nature and distribution of contaminants necessary to evaluate potential risks to human health and the environment. The CSM is an iterative approach to site characterization. The number of iterations and quantity and quality of information is a function of the complexity of site conditions and data quality objectives". This interim CSM is subject to change. AOC = Area of concern, defined by the Connecticut Department of Environmental Protection as "locations or areas at a site where hazardous waste and or hazardous substances (including petroleum products) have been used, stored, treated, handled, disposed, spilled, and/or released to the environment". Previous site investigations referred to tar impacts as tar and/or tar. For consistency, these have been changed to tar Table-1 AOC Summary.xlsx Page 10 of 10
  3. Page 43 of 203

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-032 Attachment 8 Page 43 of 203 TABLE 2 Summary of Soil Pre-Characterization Analytical Data Rockville 14W-Proposed Electrical Conduit Upgrade 13 Maple Street Rockville, CT Last Updated: 10/8/2021 Sample Name Sample Depth Sample Date Lab Sample ID Hydrocarbon (mg/Kg) CT ETPH Fuel Oil #2 / Diesel Fuel Fuel Oil #4 Fuel Oil #6 Kerosene Motor Oil Other Oil Unidentified RES DEC I/C DEC 500 NE NE NE NE NE NE NE VOCs (mg/Kg) SVOCs (mg/Kg) Acenaphthene Acenaphthylene Anthracene Benzo(a)anthracene Benzo(a)pyrene Benzo(b)fluoranthene Benzo(g,h,i)perylene Benzo(k)fluoranthene bis(2-Ethylhexyl)phthalate Chrysene Dibenz(a,h)anthracene Fluoranthene Fluorene Indeno(1,2,3-cd)pyrene Methylnaphthalene, 2Naphthalene Phenanthrene Pyrene GB PMC** I/C SEH 300 RCRA Hazardous Waste Criteria RCRA 20X Toxicity Characteristic ISS-1 0 - 2 ft 5/17/2021 CI33118 ISS-1 2 - 4 ft 5/17/2021 CI33119 ISS-2 0 - 2 ft 5/17/2021 CI33120 ISS-3 0 - 2 ft 5/17/2021 CI33121 ISS-4 0 - 2 ft 5/17/2021 CI33122 ISS-4 2 - 4 ft 5/17/2021 CI33123 ISS-4 4 - 6 ft 5/17/2021 CI33124 2,500 NE NE NE NE NE NE NE 2,500 NE NE NE NE NE NE NE 75,000 NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE 850 - 1,300 - 650 - <53 - 250 - 200 - <54 - <270 <270 <270 <270 <270 <270 <270 <53 - Varies Varies Varies Varies NE Varies - - - - BRL - - BRL BRL 1,000 1,000 1,000 1 1 1 8.4 8.4 44 84 1 1,000 1,000 1 270 1,000 1,000 1,000 2,500 2,500 2,500 7.8 1 7.8 78 78 410 780 1 2,500 2,500 7.8 1,000 2,500 2,500 2,500 84 84 400 1 1 1 1 1 11 1 1 56 56 1 5.6 56 40 40 NE 75,000 75,000 234 30 234 NE 2,340 12,300 NE NE 75,000 75,000 NE NE 75,000 75,000 75,000 NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE <1.3 7.1 2.7 1.1 8.3 5.4 13 5.8 2.8 2.9 <1.3 <1.3 10 <0.57 <1.3 <1.3 1.8 <1.3 7.8 2.2 <1 7.3 4.1 7.5 3.5 3.2 1.9 <1.3 <1.3 6 <0.56 <1.3 <1.3 <1.3 <1.3 4.4 1.7 3.3 2.8 4.5 5.7 4.6 6.2 1.2 4.3 <1.3 4.5 <0.56 <1.3 3.4 5.6 <0.25 0.48 <0.25 0.71 0.63 0.79 0.82 0.79 1 <0.25 0.92 <0.25 0.7 <0.25 <0.25 0.57 1.1 <0.25 0.97 0.28 0.42 0.67 0.59 0.82 0.58 0.62 <0.25 0.45 <0.25 0.63 <0.25 <0.25 <0.25 0.75 <0.26 0.66 <0.26 0.34 0.45 0.48 0.58 0.48 0.54 <0.26 0.32 <0.26 0.46 <0.26 <0.26 <0.26 0.52 <0.25 <0.25 <0.25 <0.25 <0.25 <0.25 <0.25 <0.25 <0.25 <0.25 <0.25 <0.25 <0.25 <0.25 <0.25 <0.25 <0.25 <0.26 1.7 0.33 <0.26 1.1 0.66 0.66 0.6 <0.26 0.58 0.18 <0.26 <0.26 0.69 <0.26 <0.26 <0.26 0.38 <0.24 <0.24 <0.24 <0.24 <0.24 <0.24 <0.24 <0.24 0.27 <0.24 0.33 <0.24 <0.24 <0.24 <0.24 0.25 0.4 Pesticides (mg/Kg) Varies Varies Varies Varies NE Varies BRL - BRL BRL BRL - - BRL - Herbicides (mg/Kg) Varies Varies Varies Varies NE Varies BRL - BRL BRL BRL - - BRL - PCBs (mg/Kg) PCBs (Total ) 1 10 NA 150 NE NE <0.39 - <0.37 <0.37 <0.36 - - <0.37 <0.34 Metals (mg/Kg) Antimony Arsenic Barium Beryllium Cadmium Chromium (Total) Copper Lead Mercury Nickel Selenium Silver Thallium Vanadium Zinc 27 10 4,700 2 34 NE 2,500 400 20 1,400 340 340 5.4 470 20,000 8,200 10 140,000 2 1,000 NE 76,000 1,000 610 7,500 10,000 10,000 160 14,000 610,000 NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA 123,000 150 2,100,000 30 15,000 NE 1,140,000 15,000 9,150 112,500 150,000 150,000 2,400 210,000 9,150,000 NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE 100 2,000 NE 20 100 NE 100 4 NE 20 100 NE NE NE <4.1 2.42 50.1 0.41 0.92 14.7 14.8 12.6 <0.03 8.94 <1.6 <0.41 <3.7 32.8 36.7 <4 2.09 35.7 0.37 0.79 14.8 8.7 7.33 <0.03 8.59 <1.6 <0.4 <3.6 28.1 28.4 <3.6 8.35 42.8 0.38 0.96 17 28.8 30.2 0.09 10.7 <1.4 <0.36 <3.2 33.9 41.8 <3.5 2.61 40.9 0.36 0.74 14.4 17.1 131 0.06 8.29 <1.4 <0.35 <3.2 25 38 <3.7 6.84 46.6 0.46 0.98 16.4 37 34.7 0.1 11.9 <1.5 <0.37 <3.3 57.3 43.4 <3.6 4.49 40.2 0.44 0.87 16.4 29 27.8 0.05 10.5 <1.4 <0.36 <3.2 30.1 35.6 <3.7 2.64 30.1 0.38 0.72 14.8 15.9 8.66 <0.03 9.44 <1.5 <0.37 <3.3 27.6 28.2 2.84 34.4 0.81 14.6 19.2 <0.03 <1.5 <0.37 - <3.7 1.08 34.7 0.37 0.69 15.8 13.2 15.5 <0.03 10.5 <1.5 <0.37 <3.3 26.5 27.8 NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA 0.06 0.5 10 0.04 0.05 0.5 13 0.15 0.02 1 0.5 0.36 0.05 0.5 50 NA NA NA NA NA NA NA NA NE NA NA NA NA NA NA NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE - <0.0005 - - 0.005 <0.004 0.021 <0.001 <0.005 <0.010 <0.010 0.01 <0.0005 <0.010 <0.020 <0.010 <0.005 <0.010 0.04 0.006 0.004 0.035 <0.001 <0.005 <0.010 <0.010 <0.010 <0.0005 <0.010 <0.020 <0.010 <0.005 <0.010 0.046 <0.0005 - <0.0005 - - - SPLP Metals* (mg/L) Antimony Arsenic Barium Beryllium Cadmium Chromium (Total) Copper Lead Mercury Nickel Selenium Silver Thallium Vanadium Zinc TCLP Lead (mg/L) Cyanide (Total) (mg/Kg) Sulfur (%) CT DEEP RSRs ISS-COMP OSS-1 1 - 3 ft 5/17/2021 5/18/2021 CI33133 CI33128 NA NA 0.15 NA 5 NE - - - 0.54 - - - - - 1,400 41,000 NA NA NE NE - - - - - - - <0.51 <0.58 NE NE NE NA NE NE - - - - - - - <0.10 - - - - - - - - 26 PASS <6 <200 <140 PASS 6.07 PASS <20 - Waste Characterization Conductivity (umhos/cm) NE NE NE NE NE NE Corrosivity NE NE NE NE NE NE Cyanide (Reactive) (mg/Kg) NE NE NE NE NE NE Flash Point (Deg F) NE NE NE NE <140 NE Ignitability (Deg F) NE NE NE NE <140 NE Paint Filter Test NE NE NE NE NE NE pH NE NE NE NE NE ≤2 or ≥12 Reactivity NE NE NE NE NE NE Sulfide (Reactive) (mg/Kg) NE NE NE NE NE NE CTDEEP RSRs- Connecticut Department of Energy and Environmental Protection Remediation Standard Regulations (Febuary 16, 2021) and Technical Support Document: Recommended Numeric Criteria for Common Additional Polluting Substances and Certain Alternative Criteria (September 20, 2018). RES DEC - Residential Direct Exposure Criteria I/C DEC - Industrial/Commercial Direct Exposure Criteria GB PMC - Pollutant Mobility Criteria for groundwater class GB I/C SEH 300 - Industrial Commercial Significant Environmental Hazard Notification Threshold Concentrations within 300 feet of a residential property RCRA - Resource Revocery and Conservation Act mg/Kg - milligrams per kilogram mg/L - milligrams per liter CT ETPH - Connecticut Extractable Total Petroleum Hydrocarbons VOCs - Volatile Organic Compounds SVOCs - Semi-Volatile Organic Compounds SPLP - Synthetic Precipitation Leaching Procedure < - Not detected above laboratory limits NE - CTDEEP RSR Criteria not established NA - Not Applicable * - RCRA Hazardous Waste concentrations for leachable metals applies to TCLP results only ** - GB PMC values are established for leachable metals and PCBs using TCLP or SPLP analysis. Only compounds detected are summarized in the table (compounds that are not listed were not detected) Boxed values indicate exceedances of RES DEC Bold values indicate exceedances of I/C DEC Gray shaded values indicate exceedance of GB PMC RED Text indicates exceedance of Significant Environmental Hazard Condition Notification Threshold Concentrations Orange shaded values indicate exceedance of RCRA 20X Toxicity Characteristic - Sample not analyzed ISS-## - Inner-substation Sample OSS-## - Outer-substation Sample VA-# - Vault Area ISS-COMP - Composite sample from ISS-1 Through ISS-4 at one foot intervals to five to six feet OSS-COMP - Composite sample from OSS-1 Through OSS-5 at one foot intervals to five to six feet and VA-1 at one foot intervals to nine J:\E\E5042 Eversource #CW2266810\155 - Rockville Utility Conduit\Report\Soil Pre-char\Table 1 - Soil Data.xlsx Page 1 of 2
  4. Page 44 of 203

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-032 Attachment 8 Page 44 of 203 TABLE 2 Summary of Soil Pre-Characterization Analytical Data Rockville 14W-Proposed Electrical Conduit Upgrade 13 Maple Street Rockville, CT Last Updated: 10/8/2021 Sample Name Sample Depth Sample Date Lab Sample ID Hydrocarbon (mg/Kg) CT ETPH Fuel Oil #2 / Diesel Fuel Fuel Oil #4 Fuel Oil #6 Kerosene Motor Oil Other Oil Unidentified RES DEC I/C DEC 500 NE NE NE NE NE NE NE VOCs (mg/Kg) SVOCs (mg/Kg) Acenaphthene Acenaphthylene Anthracene Benzo(a)anthracene Benzo(a)pyrene Benzo(b)fluoranthene Benzo(g,h,i)perylene Benzo(k)fluoranthene bis(2-Ethylhexyl)phthalate Chrysene Dibenz(a,h)anthracene Fluoranthene Fluorene Indeno(1,2,3-cd)pyrene Methylnaphthalene, 2Naphthalene Phenanthrene Pyrene GB PMC** I/C SEH 300 RCRA Hazardous Waste Criteria RCRA 20X Toxicity Characteristic OSS-2 0 - 2 ft 5/18/2021 CI33129 OSS-3 2 - 4 ft 5/18/2021 CI33130 OSS-4 1 - 3 ft 5/18/2021 CI33131 OSS-5 2 - 4 ft 5/18/2021 CI33132 VA-1 1 - 3 ft 5/17/2021 CI33125 VA-1 6 - 8 ft 5/18/2021 CI33126 OSS-COMP 5/17/2021 CI33134 P-35476 0 - 2 ft 5/18/2021 CI33127 2,500 NE NE NE NE NE NE NE 2,500 NE NE NE NE NE NE NE 75,000 NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE <53 - <55 - <270 - 770 - <280 - <56 - <260 <260 <260 <260 <260 <260 <260 660 - Varies Varies Varies Varies NE Varies BRL BRL BRL BRL BRL BRL BRL BRL 1,000 1,000 1,000 1 1 1 8.4 8.4 44 84 1 1,000 1,000 1 270 1,000 1,000 1,000 2,500 2,500 2,500 7.8 1 7.8 78 78 410 780 1 2,500 2,500 7.8 1,000 2,500 2,500 2,500 84 84 400 1 1 1 1 1 11 1 1 56 56 1 5.6 56 40 40 NE 75,000 75,000 234 30 234 NE 2,340 12,300 NE NE 75,000 75,000 NE NE 75,000 75,000 75,000 NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE <0.25 <0.25 <0.25 <0.25 <0.25 <0.25 <0.25 <0.25 <0.25 <0.25 <0.25 <0.25 <0.25 <0.25 <0.25 <0.25 <0.25 <0.25 <0.25 <0.25 <0.25 <0.25 <0.25 <0.25 <0.25 <0.25 <0.25 <0.25 <0.25 <0.25 <0.25 <0.25 <0.25 <0.25 0.51 16 11 110 40 62 34 59 110 5.3 270 1.6 32 1.1 5 19 390 <0.25 1.3 0.37 1.4 1.2 2.5 1.7 2.2 2.7 0.71 1.9 <0.25 1.6 0.33 0.39 1 2.6 <0.26 1.3 0.36 1.4 1.1 1.8 1.4 1.7 2.2 0.32 1.4 <0.26 1.2 <0.26 0.78 0.77 2.2 <0.26 <0.26 <0.26 <0.26 <0.26 <0.26 <0.26 <0.26 <0.26 <0.26 <0.26 <0.26 <0.26 <0.26 <0.26 <0.26 <0.26 <0.25 0.53 <0.25 0.79 0.86 1 1.1 0.98 0.67 1.1 0.35 0.9 <0.25 1.1 <0.25 <0.25 0.3 1.3 <0.26 3 1.1 2.5 2 3.1 2.2 2.8 4.2 0.65 3.1 0.44 2 0.89 1.2 2.5 4.4 Pesticides (mg/Kg) Varies Varies Varies Varies NE Varies - - - - - - BRL - Herbicides (mg/Kg) Varies Varies Varies Varies NE Varies - - - - - - BRL - PCBs (mg/Kg) PCBs (Total ) 1 10 NA 150 NE NE <0.36 <0.36 <0.37 <0.36 <0.37 <0.37 <0.36 <0.37 Metals (mg/Kg) Antimony Arsenic Barium Beryllium Cadmium Chromium (Total) Copper Lead Mercury Nickel Selenium Silver Thallium Vanadium Zinc 27 10 4,700 2 34 NE 2,500 400 20 1,400 340 340 5.4 470 20,000 8,200 10 140,000 2 1,000 NE 76,000 1,000 610 7,500 10,000 10,000 160 14,000 610,000 NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA 123,000 150 2,100,000 30 15,000 NE 1,140,000 15,000 9,150 112,500 150,000 150,000 2,400 210,000 9,150,000 NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE 100 2,000 NE 20 100 NE 100 4 NE 20 100 NE NE NE <3.4 1.35 45.4 0.38 0.67 13.3 12.2 22.7 <0.03 8.67 <1.4 <0.34 <3.1 27.4 27.2 <3.8 1.35 34.6 0.38 0.58 12 12.8 6.32 <0.03 7.55 <1.5 <0.38 <3.4 23.8 19.8 <3.6 11.2 51.5 0.43 0.89 15.7 48.5 38.5 0.1 10.2 <1.4 <0.36 <3.2 29.2 39.4 <3.7 4.97 54 0.33 1.04 23 32.2 73.5 0.9 11.6 <1.5 <0.37 <3.3 31.7 32.3 <3.5 6.12 47 0.36 0.76 15 57.8 27.1 0.06 9.82 <1.4 <0.35 <3.2 24.3 22.3 <3.4 1.06 16.4 <0.27 0.39 9.21 7 3.73 <0.03 5.89 <1.4 <0.34 <3.1 17.7 13 3.86 43.6 0.76 15.5 26.1 0.06 <1.4 <0.36 - <3.6 6.99 68.6 0.46 1.1 18.7 30.1 74.7 0.11 13.6 <1.5 <0.36 <3.3 31 37.7 NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA 0.06 0.5 10 0.04 0.05 0.5 13 0.15 0.02 1 0.5 0.36 0.05 0.5 50 NA NA NA NA NA NA NA NA NE NA NA NA NA NA NA NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE NE - - <0.005 0.006 0.026 <0.001 <0.005 <0.010 <0.010 <0.010 <0.0005 <0.010 <0.020 <0.010 <0.005 <0.010 <0.010 - - - 0.007 <0.004 0.037 <0.001 <0.005 <0.010 <0.010 <0.010 <0.0005 <0.010 <0.020 <0.010 <0.005 <0.010 0.031 - SPLP Metals* (mg/L) Antimony Arsenic Barium Beryllium Cadmium Chromium (Total) Copper Lead Mercury Nickel Selenium Silver Thallium Vanadium Zinc TCLP Lead (mg/L) Cyanide (Total) (mg/Kg) Sulfur (%) CT DEEP RSRs NA NA 0.15 NA 5 NE - - - - - - - - 1,400 41,000 NA NA NE NE <0.54 <0.51 <0.56 <0.51 9.89 <0.57 <0.6 25.1 NE NE NE NA NE NE - - - - - - <0.10 - - - - - - - 27 PASS <5 <200 <140 PASS 5.89 PASS <20 - Waste Characterization Conductivity (umhos/cm) NE NE NE NE NE NE Corrosivity NE NE NE NE NE NE Cyanide (Reactive) (mg/Kg) NE NE NE NE NE NE Flash Point (Deg F) NE NE NE NE <140 NE Ignitability (Deg F) NE NE NE NE <140 NE Paint Filter Test NE NE NE NE NE NE pH NE NE NE NE NE ≤2 or ≥12 Reactivity NE NE NE NE NE NE Sulfide (Reactive) (mg/Kg) NE NE NE NE NE NE CTDEEP RSRs- Connecticut Department of Energy and Environmental Protection Remediation Standard Regulations (Febuary 16, 2021) and Technical Support Document: Recommended Numeric Criteria for Common Additional Polluting Substances and Certain Alternative Criteria (September 20, 2018). RES DEC - Residential Direct Exposure Criteria I/C DEC - Industrial/Commercial Direct Exposure Criteria GB PMC - Pollutant Mobility Criteria for groundwater class GB I/C SEH 300 - Industrial Commercial Significant Environmental Hazard Notification Threshold Concentrations within 300 feet of a residential property RCRA - Resource Revocery and Conservation Act mg/Kg - milligrams per kilogram mg/L - milligrams per liter CT ETPH - Connecticut Extractable Total Petroleum Hydrocarbons VOCs - Volatile Organic Compounds SVOCs - Semi-Volatile Organic Compounds SPLP - Synthetic Precipitation Leaching Procedure < - Not detected above laboratory limits NE - CTDEEP RSR Criteria not established NA - Not Applicable * - RCRA Hazardous Waste concentrations for leachable metals applies to TCLP results only ** - GB PMC values are established for leachable metals and PCBs using TCLP or SPLP analysis. Only compounds detected are summarized in the table (compounds that are not listed were not detected) Boxed values indicate exceedances of RES DEC Bold values indicate exceedances of I/C DEC Gray shaded values indicate exceedance of GB PMC RED Text indicates exceedance of Significant Environmental Hazard Condition Notification Threshold Concentrations Orange shaded values indicate exceedance of RCRA 20X Toxicity Characteristic - Sample not analyzed ISS-## - Inner-substation Sample OSS-## - Outer-substation Sample VA-# - Vault Area ISS-COMP - Composite sample from ISS-1 Through ISS-4 at one foot intervals to five to six feet OSS-COMP - Composite sample from OSS-1 Through OSS-5 at one foot intervals to five to six feet and VA-1 at one foot intervals to nine J:\E\E5042 Eversource #CW2266810\155 - Rockville Utility Conduit\Report\Soil Pre-char\Table 1 - Soil Data.xlsx Page 2 of 2
  5. Page 45 of 203

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-032 Attachment 8 Page 45 of 203 TABLE 3 Summary of OSS-4 SEH Deliniation Analytical Data Rockville 14W-Proposed Electrical Conduit Upgrade 13 Maple Street Rockville, CT Last Updated: 11/22/2021 Sample Name CT DEEP RSRs Sample Depth I/C SEH Sample Date RES DEC I/C DEC GB PMC 300 Lab Sample ID PAHs (mg/Kg) Acenaphthene 1,000 2,500 84 NE Acenaphthylene 1,000 2,500 84 75,000 Anthracene 1,000 2,500 400 75,000 Benzo(a)anthracene 1 7.8 1 234 Benzo(a)pyrene 1 1 1 30 Benzo(b)fluoranthene 1 7.8 1 234 Benzo(g,h,i)perylene 8.4 78 1 NE Benzo(k)fluoranthene 8.4 78 1 2,340 Chrysene 84 780 1 NE Dibenz(a,h)anthracene 1 1 1 NE Fluoranthene 1,000 2,500 56 75,000 Fluorene 1,000 2,500 56 75,000 Indeno(1,2,3-cd)pyrene 1 7.8 1 NE Methylnaphthalene, 2270 1,000 5.6 NE Naphthalene 1,000 2,500 56 75,000 Phenanthrene 1,000 2,500 40 75,000 Pyrene 1,000 2,500 40 75,000 CTDEEP RSRs- Connecticut Department of Energy and Environmental Protection Remediation Standard Regulations (Febuary 16, 2021) and Technical Support Document: Recommended Numeric Criteria for Common Additional Polluting Substances and Certain Alternative Criteria (September 20, 2018). OSS-4 1 - 3 ft 5/18/2021 CI33131 OSS-4-NE 1 - 2 ft 11/18/2021 CJ80890 OSS-4-NW 1 - 2 ft 11/18/2021 CJ80892 OSS-4-SE 1 - 2 ft 11/18/2021 CJ80891 OSS-4-SW 1 - 2 ft 11/18/2021 CJ80893 0.51 16 11 110 40 62 34 59 110 5.3 270 1.6 32 1.1 5 19 390 <0.250 2.2 0.63 0.96 1.6 1.5 1.9 1.2 1.5 0.48 1.1 <0.250 2.0 <0.250 <0.250 0.48 1.8 <0.260 3.9 1.1 2.2 2.3 2.8 3 2.3 3.4 0.79 2.8 0.44 3.0 0.26 0.45 1.3 4.2 <0.250 1.1 <0.250 0.4 0.66 0.58 0.84 0.56 0.52 <0.250 0.52 <0.250 0.75 <0.250 <0.250 <0.250 0.65 <0.260 4.3 0.91 0.62 1.5 1.1 1.9 1.0 0.89 0.38 0.92 0.41 1.7 <0.260 <0.260 0.33 1.3 RES DEC - Residential Direct Exposure Criteria I/C DEC - Industrial/Commercial Direct Exposure Criteria GB PMC - Pollutant Mobility Criteria for groundwater class GB I/C SEH 300 - Industrial Commercial Significant Environmental Hazard Notification Threshold Concentrations within 300 feet of a residential property mg/Kg - milligrams per kilogram PAHs - Polycyclic Aromatic Hydrocarbons < - Not detected above laboratory limits NE - CTDEEP RSR Criteria not established Only compounds detected are summarized in the table (compounds that are not listed were not detected) Boxed values indicate exceedances of RES DEC Bold values indicate exceedances of I/C DEC Gray shaded values indicate exceedance of GB PMC RED Text indicates exceedance of Significant Environmental Hazard Condition Notification Threshold Concentrations - Sample not analyzed OSS-## - Outer-substation Sample J:\E\E5042 Eversource #CW2266810\155 - Rockville Utility Conduit\SEH Sampling\Table 1 - SEH Delineation.xlsx Page 1 of 1
  6. Page 46 of 203

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-032 Attachment 8 Page 46 of 203 TABLE 4 Summary of Concrete Chip Analytical Data Rockville 14W-Proposed Electrical Conduit Upgrade 13 Maple Street Rockville, CT Last Updated: 12/28/2021 Sample Name Sample Date Lab Sample ID Hydrocarbon (mg/Kg) CT ETPH CCS-1 11/30/2021 CJ86823 75 VOCs (mg/Kg) Naphthalene Trimethylbenzene, 1,2,4- 0.3 0.0059 PCBs (mg/Kg) PCBs (Total ) <0.35 Metals (mg/Kg) Arsenic Cadmium Chromium (Total) Lead Mercury 2.35 0.88 14.8 28.3 0.03 Waste Characterization Corrosivity PASS Cyanide (Reactive) (mg/Kg) <5.0 Flash Point (Deg F) >200 Ignitability (Deg F) PASS pH 9.2 Reactivity PASS Sulfide (Reactive) (mg/Kg) <20 mg/Kg - milligrams per kilogram CT ETPH - Connecticut Extractable Total Petroleum Hydrocarbons VOCs - Volatile Organic Compounds < - Not detected above laboratory limits Only compounds detected are summarized in the table (compounds CCS-## - Concrete Chip Sample J:\E\E5042 Eversource #CW2266810\155 - Rockville Utility Conduit\Report\Soil Pre-char\Table 4 - Concrete Page 1 of 1 Data.xlsx
  7. Page 47 of 203

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-032 Attachment 8 Page 47 of 203 APPENDIX C
  8. Page 48 of 203

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-032 Attachment 8 Page 48 of 203 Thursday, June 10, 2021 Attn: Ben Caswell Tighe & Bond 213 Court St, Suite 1100 Middletown, CT 06457 Project ID: ROCKVILLE CONDUIT PROJECT SDG ID: GCI33118 Sample ID#s: CI33118 - CI33134 This laboratory is in compliance with the NELAC requirements of procedures used except where indicated. This report contains results for the parameters tested, under the sampling conditions described on the Chain Of Custody, as received by the laboratory. This report is incomplete unless all pages indicated in the pagination at the bottom of the page are included. All soils, solids and sludges are reported on a dry weight basis unless otherwise noted in the sample comments. A scanned version of the COC form accompanies the analytical report and is an exact duplicate of the original. Enclosed are revised Analysis Report pages. Please replace and discard the original pages. If you are the client above and have any questions concerning this testing, please do not hesitate to contact Phoenix Client Services at ext.200. The contents of this report cannot be discussed with anyone other than the client listed above without their written consent. Sincerely yours, Phyllis Shiller Laboratory Director NELAC - #NY11301 CT Lab Registration #PH-0618 MA Lab Registration #M-CT007 ME Lab Registration #CT-007 NH Lab Registration #213693-A,B NJ Lab Registration #CT-003 NY Lab Registration #11301 PA Lab Registration #68-03530 RI Lab Registration #63 UT Lab Registration #CT00007 VT Lab Registration #VT11301 587 East Middle Turnpike, P.O. Box 370, Manchester, CT 06040 Telephone [phone removed] Fax [phone removed] Page 1 of 118
  9. Page 49 of 203

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-032 Attachment 8 Page 49 of 203 Environmental Laboratories, Inc. 587 East Middle Turnpike, P.O.Box 370, Manchester, CT 06045 Tel. [phone removed] Fax [phone removed] Sample Id Cross Reference June 10, 2021 SDG I.D.: GCI33118 Project ID: ROCKVILLE CONDUIT PROJECT Client Id ISS-1 (0-2`) ISS-1 (2-4`) ISS-2 (0-2`) ISS-3 (0-2`) ISS-4 (0-2`) ISS-4 (2-4`) ISS-4 (4-6`) VA-1 (1-3`) VA-1 (6-8`) P-35476 (0-2`) OSS-1 (1-3`) OSS-2 (0-2`) OSS-3 (2-4`) OSS-4 (1-3`) OSS-5 (2-4`) ISS-COMP OSS-COMP Lab Id CI33118 CI33119 CI33120 CI33121 CI33122 CI33123 CI33124 CI33125 CI33126 CI33127 CI33128 CI33129 CI33130 CI33131 CI33132 CI33133 CI33134 Matrix SOIL SOIL SOIL SOIL SOIL SOIL SOIL SOIL SOIL SOIL SOIL SOIL SOIL SOIL SOIL SOIL SOIL Page 2 of 118
  10. Page 50 of 203

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-032 Attachment 8 Page 50 of 203 Environmental Laboratories, Inc. 587 East Middle Turnpike, P.O.Box 370, Manchester, CT 06045 Tel. [phone removed] Fax [phone removed] Analysis Report FOR: Attn: Ben Caswell Tighe & Bond 213 Court St, Suite 1100 Middletown, CT 06457 June 10, 2021 Sample Information Custody Information Date Time Matrix: SOIL 05/17/21 9:30 Location Code: TIGHE-EVER Collected by: Received by: SW 05/18/21 12:20 Rush Request: 72 Hour Analyzed by: see "By" below P.O.#: 10948703 Project ID: Client ID: SDG ID: GCI33118 Phoenix ID: CI33118 Laboratory Data ROCKVILLE CONDUIT PROJECT ISS-1 (0-2`) Parameter Result RL/ PQL Units Dilution Silver Arsenic Barium Beryllium Cadmium Chromium Copper Mercury Nickel Lead Antimony Selenium Thallium Vanadium Zinc Percent Solid < 0.41 0.41 mg/Kg 2.42 0.82 mg/Kg 50.1 0.41 0.41 Date/Time By Reference 1 05/19/21 TH SW6010D 1 05/19/21 TH SW6010D mg/Kg 1 05/19/21 TH SW6010D 0.33 mg/Kg 1 05/19/21 TH SW6010D 0.92 0.41 mg/Kg 1 05/19/21 TH SW6010D 14.7 0.41 mg/Kg 1 05/19/21 TH SW6010D 14.8 0.8 mg/kg 1 05/19/21 TH SW6010D < 0.03 0.03 mg/Kg 2 05/19/21 MGH SW7471B 8.94 0.41 mg/Kg 1 05/19/21 TH SW6010D 12.6 0.41 mg/Kg 1 05/19/21 TH SW6010D < 4.1 4.1 mg/Kg 1 05/19/21 TH SW6010D < 1.6 1.6 mg/Kg 1 05/19/21 TH SW6010D < 3.7 3.7 mg/Kg 1 05/19/21 TH SW6010D 32.8 0.41 mg/Kg 1 05/19/21 TH SW6010D 36.7 0.8 mg/Kg 1 05/19/21 TH SW6010D 05/18/21 AR SW846-%Solid L/A SW3545A 86 % Soil Extraction for Pesticide Completed 05/19/21 Mercury Digestion Extraction of ETPH Completed 05/19/21 Completed 05/18/21 R/K SW3546 Soil Extraction for Herbicide Completed 05/18/21 J/D SW3550C Soil Extraction for SVOA PAH Extraction for PCB Total Metals Digest Completed 05/18/21 R/K SW3546 Completed 05/18/21 B/S/KL/ARSW3540C Completed 05/18/21 J/AG SW3050B CG/AB SW7471B Chlorinated Herbicides 2,4,5-T 2,4,5-TP (Silvex) ND 140 ug/Kg 10 05/19/21 JRB SW8151A ND 140 ug/Kg 10 05/19/21 JRB SW8151A Ver 3 Page 3 of 118

Text of RSR-032 Attachment 7.pdf

Extracted from the file · 12 pages · 13,977 characters

Text of RSR-032 Attachment 6.pdf

Extracted from the file · 335 pages · 685,056 characters

Text of RSR-032 Attachment 5.pdf

Extracted from the file · 65 pages · 194,221 characters

Text of RSR-032 Attachment 4.pdf

Extracted from the file · 570 pages · 1,357,502 characters

Text of RSR-032 Attachment 3.pdf

Extracted from the file · 8 pages · 15,762 characters

Text of RSR-032 Attachment 2.pdf

Extracted from the file · 26 pages · 3,865 characters

Text of RSR-032 Attachment 1.pdf

Extracted from the file · 18 pages · 2,673 characters

As listed on the current system

Question(s) Answered 32 (Connecticut Light and Power Company dba Eversource Energy) Date Filed: 10/30/2026

This filing on the current system (opens in a new tab)