Interrogatory responses
Answers to questions 38
Files5
RSR-038_Final.pdf
PDF · 146 KB · 7 pagesText searchable
Download RSR-038_Final.pdfRead the text of RSR-038_Final.pdf
RSR-038 Attachment 1 REDACTED.pdf
PDF · 4.6 MB · 19 pagesText read by machine from a scan; may contain errors, especially in numbers
Download RSR-038 Attachment 1 REDACTED.pdfScanned pages and text of RSR-038 Attachment 1 REDACTED.pdf
RSR-038 Attachment 2 REDACTED.pdf
PDF · 798 KB · 1 pageText read by machine from a scan; may contain errors, especially in numbers
Download RSR-038 Attachment 2 REDACTED.pdfScanned pages and text of RSR-038 Attachment 2 REDACTED.pdf
RSR-038 Attachment 3.pdf
PDF · 502 KB · 1 pageText searchable
Download RSR-038 Attachment 3.pdfRead the text of RSR-038 Attachment 3.pdf
RSR-038 Attachment 4 REDACTED.pdf
PDF · 51 MB · 126 pagesText read by machine from a scan; may contain errors, especially in numbers
Download RSR-038 Attachment 4 REDACTED.pdfScanned pages and text of RSR-038 Attachment 4 REDACTED.pdf
Scanned pages and machine-read text of RSR-038 Attachment 1 REDACTED.pdf

The scanned page Machine-read text
The Connecticut Light and Power Company REDACTED d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-038 Attachment 1 REDACTED Page 1 of 19 NORTHEAST UTILITIES THE CONNECTICUT LIGHT AND POWER COMPANY WESTERN MASSACHUSETTS ELECTRIC COMPANY HOLYOKE WATER POWER COMPANY NORTHEAST UTILITIES SERVICE COMPANY NORTHEAST NUCLEAR ENERGY COMPANY General Offices • Selden Street, Berlin, Connecticut P.O. BOX 270 HARTFORD, CONNECTICUT 06141-0270 [redacted] April 13, 1988 D01928 Mr. Ronald Corey, Fire Marshall City of Torrington 111 Water Street Torrington, Connecticut 06790 Reference: Letter and Notification, [redacted] o R. Corey, dated May 8, 1986. Dear Mr. Corey: Torrington Area Work Center Notification of Underground Storage Tanks Northeast Utilities Service Company (NUSCO), as agent for the Connecticut Light and Power Company (CL&P), submits an amended Copy No. 2 of Notification Form EPHM-6 for underground storage tanks at CL&P's Torrington Area Work Center. The form submitted to you on May 8, 1986 (Referenced) has been amended to reflect the removal of all of the tanks (A1, B2, C3, D4) at the site. If you have any questions, please call [redacted] NUSCO Generation Facilities Licensing, at [redacted]. Very truly yours, NORTHEAST UTILITIES SERVICE COMPANY As Agent for The Connecticut Light and Power Company [redacted] [redacted] Senior Vice President [redacted] By: C. F. Sears Vice President
The scanned page Machine-read text
The Connecticut Light and Power Company REDACTED d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-038 Attachment 1 REDACTED Page 2 of 19 Mr. Ronald Corey, Fire Marshall DO1928/Page 2 April 13, 1988 Enclosure cc: w/enclosure (Copy 1) Mr. Scott Deshefy Hazardous Material's Management Unit Department of Environmental Protection 165 Capitol Avenue Hartford, Connecticut 06106 Mr. Richard Ciasullo Department of Environmental Protection 165 Capitol Avenue Hartford, Connecticut 06106
The scanned page Machine-read text
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-038 Attachment 1 REDACTED Page 3 of 19 REDACTED UNDERGROUND STORAGE FACILITY NOTIFICATION | PG. 2 of 1 | SITE ID | FOR STATE AGENCY USE ONLY | A. SITE I.D. | B. DATE RCVD BY D E P | C. DATE ENTERED | D. GRID COORDINATES X Y | E. DOES FACILITY MEET NEW REQUIREMENTS? YES NO STATE OF CONNECTICUT Department of Environmental Protection UNDERGROUND STORAGE FACILITIES PROGRAM HAZARDOUS MATERIALS MANAGEMENT UNIT 165 Capitol Avenue, Hartford, CT 06106 TEL. 566-4630 PLEASE TYPE. ALL THREE COPIES MUST BE LEGIBLE! Refer to INSTRUCTIONS FOR FILING NOTIFICATION before completing form. EPHM-6 NEW 10/85 1a. FIRST NOTIFICATION OR b. SUBSEQUENT NOTIFICATION (If checked, enter No.) SECTION A SECTION B
SECTION C 20. HAVE YOU ATTACHED SKETCH OF TANKS AND LOCATION? [X] YES 21. COMMENTS: SECTION D 22. CERTIFICATION: I certify under penalty of law that I have personally examined and am familiar with the information submitted in this and all attached documents and that based on my inquiry of those individuals immediately responsible for obtaining the information, I believe that the submitted information is true, accurate and complete. Penalties: any owner who knowingly fails to notify shall be subject to a civil penalty not to exceed $10,000 for each tank for which notification is not given or for which false information is submitted.4. LOCATION OF FACILITY SITE NAME: Torrington Area Work Center NO. AND STREET: 174 Franklin Street NEAREST INTERSECTING STREET: Horwinton Ave. CITY OR TOWN: Torrington STATE: CT 5. LATITUDE: 41° 48' 00" LONGITUDE: 73° 06' 55" 5. BUSINESS NAME AND 6. MAILING ADDRESS NAME: The Connecticut Light + Power Co. (CL4P) NO. AND STREET: P O Box 270 CITY OR TOWN: Hartford STATE: CT ZIP CODE: 06141-0270 7. FACILITY OWNER NAME: CL&P NO. AND STREET: Same as Above CITY OR TOWN STATE ZIP CODE 8. TYPE OF OWNER PRIVATE (checked) STATE MUNICIPAL FEDERAL (G.S.A. No.) 9. OPERATOR/CONTACT PERSON [redacted] NO. AND STREET: 174 Franklin Street CITY OR TOWN: Torrington STATE: CT ZIP CODE: 06790 TELEPHONE: 1203 482-4471 10. TANK ID 11a. DATE OF INSTALLATION (Mo./Yr.) 11b. LIFE EXPECTANCY (in years) 12a. TOTAL CAPACITY (Gals.) IN USE ABANDONED IN PLACE 12b. STATUS EST. QUANTITY LEFT STORED (if any) (Gals.) REMOVED DATE TANK LAST USED (Mo./Yr.) 13. TYPE OF CONTENTS OIL/PETROLEUM PRODUCT CHEMICAL LIQUID 14. CONTENTS CHEMICAL NAME OF PRINCIPAL SUBSTANCE (not trade name.) (Enter C.A.S. No., if known) 15. CONSTRUCTION MATERIALS STEEL FIBERGLASS REINFORCED PLASTIC OTHER (Specify from list A) c. INTERNAL UNLINED b. EXTERNAL UNLINED CATHODIC PROTECTION COATED/WRAPPED CATHODIC PROTECTION OTHER (Specify from list B) 16. PROTECTION 17. INTEGRAL PIPING SYSTEM a. CONSTRUCTION AND PROTECTION (from list A/B) b. DATE OF INSTALLATION OR REPLACEMENT (Mo./Yr.) 18. MONITORING SYSTEM (Specify type from list B) 19. FAILURE DETERMINATION CONDUCTED? (if "YES", enter DATE and attach results; if "NO", enter "NO") Example 5/75 30 5000 X X X H 5 5/75 U NO Example 7/60 - 8000 X 8/78 X X E 7 7/60 U - A1 12/78 15 10,000 X 4/88 X Regular Gasoline X X E 7E 12/78 O 3-15-84 B2 1/64 15 4,000 X 3/88 X Diesel Fuel X X E 7E 1/64 O 3-15-84 C3 1/64 15 4,000 X 3/88 X Unleaded Gasoline X X E 7E 1/64 O 3-15-84 D4 1/60 15 500 X 3/88 X Waste Oil X X E 7E 1/60 U NO
22c. NAME (type or print) [redacted] 22d. OFFICIAL TITLE | Vice President / Senior Vice President COPY 1: SEND TO DEP: 165 CAPITOL AVE. HARTFORD, CT 0610622a. SIGNATURE X [redacted] 22b. DATE SIGNED 13 April 1988 
The scanned page Machine-read text
REDACTED The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-038 Attachment 1 REDACTED Page 4 of 19 CONN LIGHT & POWER CO. NORTHEAST UTILITIES WORK ORDER SKETCH SHEET
SKETCH INDICATE NORTH AND NAME STREETS Not To Scale B2 A1 21' 140' 159' 177' 44' 275' 255' D4 C3 GARAGE TRANSMISSION TORRINGTON SERVICE BUILDING HARWINTON SCHIBI ST. AVE. OP418? REV. 10-82 DEST. SAME AS ATT. REC. DRAWN BY | TELEPHONE EXT.DISTRICT / REGION TOWN DATE MAP NO. WORK ORDER NO. ACTV. SHEET OF TORRINGTON / WESTERN TORRINGTON 
The scanned page Machine-read text
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-038 Attachment 1 REDACTED Page 5 of 19 REDACTED TO: File FROM: John Szymanski [signature] April 14, 1988 SUBJECT: Torrington AWC Tank removals were conducted at the Torrington AWC during the months of March and April 1988. o During March 1988: One (1) 4000 gallon unleaded gasoline tank and One (1) 500 gallon oil tank were removed; no problems o On March 30, 1988: Notified that (1) 4000 gallon diesel tank was removed with heavy rusting and several apparent holes the size of dimes. o On March 30, 1988: Examined site and took three (3) samples from excavation hole and one (1) sample from diesel tank to have material analyzed and identified by LAB per request by DEP Field Inspector, Richard Ciasullo. o On March 31, 1988: Samples dropped off for analyzing and identification at Souther-Newlands Laboratory. o On April 4, 1988: Souther Newland Laboratory called EPD office to report on lab findings. - Sample from diesel tank identified as diesel fuel - The three (3) samples from the excavation hole all had the same characteristic profiles, but it didn't match that of gasoline or diesel fuel and that it would take two to three weeks to identify samples from the excavation hole. o On Aril 4, 1988: Notified R. Robinson of the DEP Clean Water Group of the test results and asked for permission to continue tank installation construction after film cleaned off top of water and remainder of gray colored gravel removed from hole. Mr. Robinson gave approval to continue construction if I inspected site and assured this was done. o On April 6, 1988: NUSCO construction removed film from water and lowered water table by sucking out 3200 gallons of contaminated water which was hauled off site as contaminated waste water. Removed the remainder of gray contaminated gravel from excavation hole. o On April 6, 1988 after water table lowered gasoline film and strong fumes entered the excavation hole. The fire marshal was notified, who requested DEP to inspect the hole. Concern was generated regarding 10,000 gallon unleaded gasoline tank in the same vicinity where gas fumes and film were found. Construction stopped. o On April 7, 1988: DEP Field Inspector Richard Ciasullo and
The scanned page Machine-read text
The Connecticut Light and Power Company REDACTED d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-038 Attachment 1 REDACTED Page 6 of 19 Torrington Fire Marshal Ron Corey arrived on site and gave us two alternatives: 1. Test tank full of product and be ready to remove it immediately if tank leaks; 2. Remove 10,000 gallon unleaded tank. o April 7, 1988: Discussions were held between Area Superintendent Walt Wadman, Ken Busick, Frank Melluzzo, Bud Meyer, John Betz, Jack Farrel and John Szymanski to discuss options and make decision as to disposition of 10,000 gallon gasoline tank. Final consensus was to remove tank based on presence of gasoline odor and fumes in area, water level in tank raised when emptied of product, bottom ash found in vicinity of tank, tank had been unprotected for 10 years, the older unprotected tank 4000 diesel came out of ground looking like swiss cheese. o April 7, 1988: Removed 10,000 gallon unleaded gasoline tank, some heavy rusting and pitting visible on tank but there was no apparent holes. Backfill around tank was improper per today's installation standards (very large boulders, large gravel and some sand) there were no hold down straps on tank, and bottom ash in close proximity to tank. Wet lines were heavily rusted in one large area.
The scanned page Machine-read text
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-038 Attachment 1 REDACTED Page 7 of 19 REDACTED Distribution: [redacted]Claims and Insurance [redacted]s. and Test Department [redacted]Regional Operations - WMECO [redacted]struction [redacted]HP [redacted]rans. SS and Mtce. [redacted] Trans. Bldg. Eng. Design [redacted]nsportation [redacted] EPD [redacted]ores [redacted] EPD [redacted]cilities Management [redacted] Legal [redacted] Nuclear Prod. [redacted]en. Fac. Lic. Dept. bsl cc: [redacted]
The scanned page Machine-read text
The Connecticut Light and Power Company REDACTED d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-038 Attachment 1 REDACTED Page 8 of 19 TORRINGTON AUG / CT Bemis / Laura Lionts leak lokator hunter ENVIRONMENTAL SERVICES, INC. 18 GREAT VALLEY PARKWAY, SUITE 6 MALVERN, PA 19355 [phone removed] [phone removed] TEST RESULTS DATE OF TEST | 07-6-85 CONTRACT NUMBER
TEST RESULTS SUMMARYCUSTOMER Northeast Utilities LOCATION – IDENTIFICATION NUMBER NAME ADDRESS 178 Franklin Drive CITY Torrington STATE Conn LEAK LOKATOR USE ONLY CONCL. CODE
OTHER INFORMATION FINAL REPORT PRODUCT LINES – HYDROSTATIC PRESSURE TEST RESULTSNO. SYSTEM PRODUCT TANK SIZE GALLONS DIA/MATL WATER INCHES LEAK LOKATOR RESULTS LEVEL INCHES ALR GPH CONCLUSION RECOMMENDATIONS TEST TANK SYS II No Lead Tank #I 4000 64/37 1 1/2" 106" .039 Tight II No Lead Tank #II 4000 64/37 1 1/2" 95" .038 Tight VII Regular Lead 10000 96/3T 1 1/2" 113" .038 Tight
NOTE: On suction systems, NEVER put more than 15 psi on any pump system. OTHER CONTRACTORS, OFFICIALS, CUSTOMER REPRESENTATIVES PRESENT DETAIL OF TEST RESULTSNO. SYSTEM PRODUCT TYPE OF PUMP REMOTE TYPE OF PUMP SUCTION # APPLIED MINUTES APPLIED PRODUCT LOSS CC'S PRODUCT LOSS GPH CONCLUSION/RESULT II No Lead Tank I > ✓ DL Pressure test test X II No Lead Tank II > ✓ 170 Pressure test test X III Regular Leaded > Pump ✓ Side [illegible] [illegible] X X Tight NO. SYSTEM PRODUCT TEST NO. TEST LEVEL (INCHES) CLOCK START DURATION HRS.-MIN. LEAK RATE CC/DIV LEAK RATE CC/MIN TEMP COMP Δ°F TEMP COMP CC/MIN ABSOLUTE LEAK RATE CC/MIN ABSOLUTE LEAK RATE GPH CHECK TEST Y or N I No Lead Tank I 1 106" 9:45 31 min .39 +25.95 +.161 +33.80 -1.85 -.039 N II No Lead Tank II 1 95" 7:52 31 min .47 +2.82 +.636 +6.37 -2.44 -.038 N III Regular Leaded 1 142" 11:46 20 min .35 +21.47 +.655 23.88 -2.41 -.038 N 
The scanned page Machine-read text
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-038 Attachment 1 REDACTED Page 9 of 19 REDACTED ENVIRONMENTAL SERVICES, INC. 18 GREAT VALLEY PARKWAY, SUITE 6 MALVERN, PA 19355 [phone removed] [phone removed] Bemis | TORRINGTON AWG / CT Laura [illegible] leak lokator TEST RESULTS DATE OF TEST | 03-6-8? CONTRACT NUMBER CUSTOMER Northeast Utilities LOCATION – IDENTIFICATION NUMBER
TEST RESULTS SUMMARYADDRESS 178 Franklin Drive NAME CITY Torrington STATE Con
OTHER INFORMATION FINAL REPORT PRODUCT LINES – HYDROSTATIC PRESSURE TEST RESULTSNO. SYSTEM PRODUCT TANK SIZE GALLONS DIA/MATL WATER INCHES LEAK LOKATOR RESULTS LEVEL INCHES ALR GPH CONCLUSION RECOMMENDATIONS LEAK LOKATOR USE ONLY CONCL. CODE TEST TANK SYS I NO LEAD TANK I 4500 64.37 1 1/2" 166" -.029 Tight II NO LEAD TANK II 4500 64.37 1 1/2" 95" -.038 Tight III REGULAR LEADED 10000 96 x T 1 1/2" 115" -.026 Tight
NOTE: On suction systems, NEVER put more than 15 psi on any pump system. OTHER CONTRACTORS, OFFICIALS, CUSTOMER REPRESENTATIVES PRESENT DETAIL OF TEST RESULTSNO. SYSTEM PRODUCT TYPE OF PUMP REMOTE SUCTION # APPLIED MINUTES APPLIED PRODUCT LOSS CC'S PRODUCT LOSS GPH CONCLUSION/RESULT I NO LEAD TANK I ✓ DO DO [illegible] test X II NO LEAD TANK II ✓ test X III REGULAR LEADED ✓ ✓ 110 Due X III REGULAR LEADED ✓ Pump ✓ [illegible] [illegible] [illegible] [illegible] Tight
* LEVEL – INCHES FROM TANK BOTTOM TO TEST LEVEL ALR – ABSOLUTE LEAK RATE (MEASURED LEAK RATE – TEMPERATURE COMPENSATION) IN GALLONS PER HOUR CONCLUSION – NFPA 329 CRITERION OF ± 0.05 GPH IS USED TO CERTIFY TIGHTNESS CERTIFICATION This is to certify that the above described tank systems were tested, using the HUNTER ENVIRONMENTAL SERVICES, INC. LEAK LOKATOR according to all standard operating procedures. Those indicated as tight meet the criterion established by the National Fire Protection Association Pamphlet 329 for Precision Testing.NO. SYSTEM PRODUCT TEST NO. TEST LEVEL (INCHES) TIME CLOCK START TIME DURATION HRS.-MIN. LEAK RATE CC/DIV LEAK RATE CC/MIN TEMPERATURE COMPENSATION Δ°F TEMPERATURE COMPENSATION CC/MIN ABSOLUTE LEAK RATE CC/MIN ABSOLUTE LEAK RATE GPH CHECK TEST Y or N I NO LEAD TANK I 1 166" 9:45 31 min .39 +25.95 +.141 +27.82 -1.85 -.029 N II NO LEAD TANK II 1 95" 9:52 35 min 4.17 12.08 +.036 16.37 -2.44 -.038 N III REGULAR LEADED 1 114" 9:46 30 min -.37 +21.17 +.255 23.66 -2.41 -.038 N TESTS CONDUCTED BY CERTIFIED BY TEST VAN NO. [illegible] SIGNATURE [illegible] TANK TESTING SPECIALIST [illegible] NAME [illegible] DATE [illegible] TANK TESTING SPECIALIST [illegible] TITLE [illegible] 
The scanned page Machine-read text
The Connecticut Light and Power Company REDACTED d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-038 Attachment 1 REDACTED Page 10 of 19 TANK AND LOCATION DATA DATE: 03-6-85
SCHEMATIC: Building PUMP NO LEAD II 4000gal 64" NO LEAD II 4000gal 64" NO LEAD PUMP VENT Regular PUMPS VENT Regular LEADED 10000gal 96" BuildingCUSTOMER: Northeast Utilities CITY: Torrington I.D. # STATE: Conn WEATHER TIME TEMPERATURE COMMENTS BEFORE TEST – AFTER TEST –
VAPOR RECOVERY TYPE VENT CONFIGURATION P-V VENT VALVE TYPEPRODUCT/TANK NO. NO LEAD I NO LEAD II Regular BEFORE DELIVERY LEVEL Fill Gauge Fill Gauge Fill Gauge Fill Gauge Fill Gauge LEVEL Full GALLONS WATER 1½" 1½" 1½" TOP OF RISER 97 96 101 132 GRADE 160 163 162 137 DROP TUBE AL AL AL CAPACITY, GALLONS 4000 4000 10000 DIAMETER, INCHES 64 64 64 MATERIAL STEEL STEEL STEEL PUMP TYPE Gasboy [illegible] Bennett TYPE OF COVER TAN TAN TAN AGE OF TANK UK UK UK SIPHON NO NO NO TANK OPENINGS 1-4" 1-2" 1-4" 1-2" 1-4" EXTRACTORS NO NO NO
ADDITIONAL CHARGES: (pumpovers, overtime, etc.) [illegible] [illegible] *Data obtained from ☐ Station ☐ LL Charts ☐ Other ______REPLACEMENT PARTS: PART # DESCRIPTION QUANTITY PRICE #701 [illegible] 1 [illegible] #124 [illegible] 1 [illegible] # 6" Quick Tite 2-gauge (wire) 1 [illegible]
Scanned pages and machine-read text of RSR-038 Attachment 2 REDACTED.pdf

The scanned page Machine-read text
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-038 Attachment 2 REDACTED Page 1 of 1 REDACTED UNDERGROUND STORAGE FACILITY NOTIFICATION
STATE OF CONNECTICUT Department of Environmental Protection UNDERGROUND STORAGE FACILITIES PROGRAM HAZARDOUS MATERIALS MANAGEMENT UNIT 165 Capitol Avenue, Hartford, CT 06106 TEL. 556-4630 PLEASE TYPE. ALL THREE COPIES MUST BE LEGIBLE! Refer to INSTRUCTIONS FOR FILING NOTIFICATION before completing form. 1a. FIRST NOTIFICATION OR b. SUBSEQUENT NOTIFICATION (If checked, enter No.) SITE I.D.2. PG. of 1 1
SECTION A/B3. FOR STATE AGENCY USE ONLY A. SITE I.D. B. DATE RCVD BY D.E.P. C. DATE ENTERED D. GRID COORDINATES X ___ Y ___ E. DOES FACILITY MEET NEW REQUIREMENTS? YES NO
[redacted] SECTION C4. LOCATION OF FACILITY SITE NAME: East Hampton Service Center NO. AND STREET: 22 East High Street NEAREST INTERSECTING STREET: Route 2 CITY OR TOWN: East Hampton STATE: CT 5. LATITUDE: 41° 34' 56" LONGITUDE: 72° 30' 14" 6. BUSINESS NAME AND MAILING ADDRESS NAME: The Connecticut Light & Power Company NO. AND STREET: P.O. Box 270 CITY OR TOWN: Hartford STATE: CT ZIP CODE: 061410270 7. FACILITY OWNER NAME: The Connecticut Light & Power Company NO. AND STREET: P.O. Box 270 CITY OR TOWN: Hartford STATE: CT ZIP CODE: 061410270 8. TYPE OF OWNER X PRIVATE STATE MUNICIPAL FEDERAL (G.S.A. No. ___) 9. OPERATOR/CONTACT PERSON [redacted] NO. AND STREET: 22 East High Street CITY OR TOWN: East Hampton STATE: CT ZIP CODE: 06424
20. HAVE YOU ATTACHED SKETCH OF TANKS AND LOCATION? X YES 21. COMMENTS: 16b coal tar epoxy. Tanks B2, D4, E5 & F6 budgeted for cathodic protection in 1986. A1 is also for [illegible] [illegible] SECTION D 22. CERTIFICATION: I certify under penalty of law that I have personally examined and am familiar with the information submitted in this and all attached documents and that based on my inquiry of those individuals immediately responsible for obtaining the information, I believe that the submitted information is true, accurate and complete. Penalties: any owner who knowingly fails to notify shall be subject to a civil penalty not to exceed $10,000 for each tank for which notification is not given or for which false information is submitted.10. TANK ID. 11a. DATE OF INSTALLATION (Mo./Yr.) 11b. TANK LIFE EXPECTANCY (# of years) 12a. TOTAL CAPACITY (Gals.) 12b. STATUS: IN USE ABANDONED IN PLACE EST. QUANTITY LEFT STORED (if any) (Gals.) REMOVED DATE TANK LAST USED (Mo./Yr.) 13. TYPE OF CONTENTS: OIL/PETRO-LEUM PRODUCT CHEMICAL LIQUID 14. CONTENTS: CHEMICAL NAME OF PRINCIPAL SUBSTANCE (not trade name.) (Enter C.A.S. No. if known) 15. CONSTRUCTION MATERIALS: STEEL FIBERGLASS REINFORCED PLASTIC OTHER (Specify from list A) 16. PROTECTION a. INTERNAL: LINED UNLINED; b. EXTERNAL: CATHODIC PROTECTION COATED/WRAPPED CATHODIC PROTECTION OTHER (Specify from list B) 17. INTEGRAL PIPING SYSTEM a. CONSTRUCTION PROTECTION (See list B) b. DATE OF INSTALLATION OR REPLACEMENT (Mo./Yr.) 18. MONITORING SYSTEM (Specify type from list B) 19. FAILURE DETERMINATION CONDUCTED? (If "YES," enter DATE and attach results. If "NO," enter "NO") Example 5/75 30 5000 X X X X H 5 5/75 U NO Example 7/60 - 8000 X 8/78 X X X E 7 7/60 U — A1 /72 15 275 X X X X X H 7 /72 H 092584 B2 /72 15 10000 X X X X 7 /72 O 092684 (10-14-86 / 092684 struck through) C3 '30 30 10000 X 0 11/84 X X 8 /80 O 092684 D4 '72 15 275 X X X X 7 /72 U 092584 E5 ,72 15 550 X X X X 7 /72 U 092884 P6 ,72 15 550 X X X X 7 /72 U 092884
COPY 422a. SIGNATURE X [redacted] 22b. DATE SIGNED 5/5/86 22c. NAME (Type or Print) [redacted] 22d. OFFICIAL TITLE (of owner or authorized representative) Senior Vice President
Text of RSR-038 Attachment 3.pdf
Extracted from the file · 1 page · 146 characters
Scanned pages and machine-read text of RSR-038 Attachment 4 REDACTED.pdf
Page 47 of 126
Full-size scan of page 47 (opens in a new tab)In the PDF: page 47 (opens in a new tab)
The scanned page Machine-read text
The Connecticut Light and Power Company REDACTED d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-038 Attachment 4 REDACTED Page 47 of 126 ENVIRONMENTAL SCIENCE CORPORATION 362 INDUSTRIAL PARK ROAD MIDDLETOWN, CT 06457 [phone removed], FAX [phone removed] LABORATORY REPORT LAB. REPORT NO. C-11783 State Certification No. PH-0476 CLIENT Mr. [redacted] Northeast Utilities 100 Corporate Place Rocky Hill, CT 06067 DATE RECEIVED 08/28/89 PURCHASE ORDER NO. 001569 CLIENT I.D. NEU CLIENT PROJECT NO. Madison Service Center - 24 HOUR PRIORITY
** TEST ** (ALL UNITS ARE PPB) ** EPA METHOD 8020SAMPLE ID: WELL #1 WELL #2 LOCATION: MADISON SERV. CT MADISON SERV. CT TYPE: WATER WATER DATE: 08/28/89 08/28/89
< - Below Minimum Detectable Level 08/31/89 - 3 - [redacted] DATE REPORTED LABORATORY DIRECTOR [redacted]Benzene 2382 3 Chlorobenzene < 100 < 1 1,2-Dichlorobenzene < 100 < 1 1,3-Dichlorobenzene < 100 < 1 1,4-Dichlorobenzene < 100 < 1 Ethylbenzene 862 < 1 Toluene 5548 2 Xylenes 3597 5 Page 48 of 126
Full-size scan of page 48 (opens in a new tab)In the PDF: page 48 (opens in a new tab)
The scanned page Machine-read text
The Connecticut Light and Power Company REDACTED d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-038 Attachment 4 REDACTED Page 48 of 126 ENVIRONMENTAL SCIENCE CORPORATION LABORATORY REPORT LAB. REPORT NO. C-11760 362 INDUSTRIAL PARK ROAD MIDDLETOWN, CT 06457 [phone removed], FAX [phone removed] State Certification No. PH-0476 CLIENT Mr. [redacted] Northeast Utilities 100 Corporate Place Rocky Hill, CT 06067
Madison - 24-48 HOUR PRIORITYDATE RECEIVED 08/25/89 PURCHASE ORDER NO. 001569 CLIENT I.D. NEU CLIENT PROJECT NO.
** TEST ** ** EPA METHOD 8010SAMPLE ID: B-1 S-2 B-1S-4 CONTAM. SOIL LOCATION: MADISON MADISON MADISON TYPE: SOIL/SOLID SOIL/SOLID SOIL/SOLID DATE: 08/22/89 08/22/89 08/22/89
< - Below Minimum Detectable LevelBenzyl Chloride < 0.2 mg/kg < 1 ug/kg < 0.2 mg/kg Bis(2-Chloroethoxy)Methane < 0.2 mg/kg < 1 ug/kg < 0.2 mg/kg Bis(2-Chloroisopropyl)Ether < 0.2 mg/kg < 1 ug/kg < 0.2 mg/kg Bromobenzene < 0.2 mg/kg < 1 ug/kg < 0.2 mg/kg Bromodichloromethane < 0.2 mg/kg < 1 ug/kg < 0.2 mg/kg Bromoform < 0.2 mg/kg < 1 ug/kg < 0.2 mg/kg Bromomethane < 0.2 mg/kg < 1 ug/kg < 0.2 mg/kg Carbon Tetrachloride < 0.2 mg/kg < 1 ug/kg < 0.2 mg/kg Chloroacetaldehyde < 0.2 mg/kg < 1 ug/kg < 0.2 mg/kg Chloral < 0.2 mg/kg < 1 ug/kg < 0.2 mg/kg Chlorobenzene < 0.2 mg/kg < 1 ug/kg < 0.2 mg/kg Chloroethane < 0.2 mg/kg < 1 ug/kg < 0.2 mg/kg Chloroform < 0.2 mg/kg < 1 ug/kg < 0.2 mg/kg 1-Chlorohexane < 0.2 mg/kg < 1 ug/kg < 0.2 mg/kg 2-Chloroethyl Vinyl Ether < 0.2 mg/kg < 1 ug/kg < 0.2 mg/kg Chloromethane < 0.2 mg/kg < 1 ug/kg < 0.2 mg/kg Chloromethyl Methyl Ether < 0.2 mg/kg < 1 ug/kg < 0.2 mg/kg Chlorotoluene < 0.2 mg/kg < 1 ug/kg < 0.2 mg/kg Dibromochloromethane < 0.2 mg/kg < 1 ug/kg < 0.2 mg/kg Dibromomethane < 0.2 mg/kg < 1 ug/kg < 0.2 mg/kg 1,2-Dichlorobenzene < 0.2 mg/kg < 1 ug/kg < 0.2 mg/kg 1,3-Dichlorobenzene < 0.2 mg/kg < 1 ug/kg < 0.2 mg/kg 1,4-Dichlorobenzene < 0.2 mg/kg < 1 ug/kg < 0.2 mg/kg Dichlorodifluoromethane < 0.2 mg/kg < 1 ug/kg < 0.2 mg/kg 1,2-Dichloroethane < 0.2 mg/kg < 1 ug/kg < 0.2 mg/kg 08/29/89 - 1 - [redacted] DATE REPORTED LABORATORY DIRECTOR Page 49 of 126
Full-size scan of page 49 (opens in a new tab)In the PDF: page 49 (opens in a new tab)
The scanned page Machine-read text
The Connecticut Light and Power Company REDACTED d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-038 Attachment 4 REDACTED Page 49 of 126 ENVIRONMENTAL SCIENCE CORPORATION LABORATORY REPORT LAB. REPORT NO. 362 INDUSTRIAL PARK ROAD C-11760 MIDDLETOWN, CT 06457 State Certification No. PH-0476 [phone removed], FAX [phone removed] CLIENT Mr. [redacted] Northeast Utilities 100 Corporate Place Rocky Hill, CT 06067
Madison - 24-48 HOUR PRIORITYDATE RECEIVED 08/25/89 PURCHASE ORDER NO. 001569 CLIENT I.D. NEU CLIENT PROJECT NO.
** TEST ** EPA METHOD 8010 (continued)SAMPLE ID: B-1 S-2 B-1S-4 CONTAM. SOIL LOCATION: MADISON MADISON MADISON TYPE: SOIL/SOLID SOIL/SOLID SOIL/SOLID DATE: 08/22/89 08/22/89 08/22/89
< - Below Minimum Detectable Level1,1-Dichloroethane < 0.2 mg/kg < 1 ug/kg < 0.2 mg/kg 1,1-Dichloroethylene < 0.2 mg/kg < 1 ug/kg < 0.2 mg/kg Trans-1,2-Dichloroethylene < 0.2 mg/kg < 1 ug/kg < 0.2 mg/kg Dichloromethane < 0.2 mg/kg < 1 ug/kg < 0.2 mg/kg 1,2-Dichloropropane < 0.2 mg/kg < 1 ug/kg < 0.2 mg/kg 1,3-Dichloropropylene < 0.2 mg/kg < 1 ug/kg < 0.2 mg/kg 1,1,2,2-Tetrachloroethane < 0.2 mg/kg < 1 ug/kg < 0.2 mg/kg 1,1,1,2-Tetrachloroethane < 0.2 mg/kg < 1 ug/kg < 0.2 mg/kg Tetrachloroethylene < 0.2 mg/kg < 1 ug/kg < 0.2 mg/kg 1,1,1-Trichloroethane < 0.2 mg/kg < 1 ug/kg < 0.2 mg/kg 1,1,2-Trichloroethane < 0.2 mg/kg < 1 ug/kg < 0.2 mg/kg Trichloroethylene < 0.2 mg/kg < 1 ug/kg < 0.2 mg/kg Trichlorofluoromethane < 0.2 mg/kg < 1 ug/kg < 0.2 mg/kg Trichloropropane < 0.2 mg/kg < 1 ug/kg < 0.2 mg/kg Vinyl Chloride < 0.2 mg/kg < 1 ug/kg < 0.2 mg/kg Trans-1,3-Dichloropropylene < 0.2 mg/kg < 1 ug/kg < 0.2 mg/kg
[redacted]08/29/89 - 2 - [redacted] DATE REPORTED LABORATORY DIRECTOR Page 50 of 126
Full-size scan of page 50 (opens in a new tab)In the PDF: page 50 (opens in a new tab)
The scanned page Machine-read text
The Connecticut Light and Power Company REDACTED d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-038 Attachment 4 REDACTED Page 50 of 126 ENVIRONMENTAL SCIENCE CORPORATION 362 INDUSTRIAL PARK ROAD MIDDLETOWN, CT 06457 [phone removed], FAX [phone removed] LABORATORY REPORT LAB. REPORT NO. C-11760 State Certification No. PH-0476 CLIENT Mr. [redacted] Northeast Utilities 100 Corporate Place Rocky Hill, CT 06067
Madison - 24-48 HOUR PRIORITYDATE RECEIVED 08/25/89 PURCHASE ORDER NO. 001569 CLIENT I.D. NEU CLIENT PROJECT NO.
** TEST ** ** EPA METHOD 8020SAMPLE ID: B-1 S-2 B-1S-4 CONTAM. SOIL LOCATION: MADISON MADISON MADISON TYPE: SOIL/SOLID SOIL/SOLID SOIL/SOLID DATE: 08/22/89 08/22/89 08/22/89
< - Below Minimum Detectable LevelBenzene 0.26 mg/kg < 1 ug/kg 17.2 mg/kg Chlorobenzene < 0.2 mg/kg < 1 ug/kg < 0.2 mg/kg 1,2-Dichlorobenzene < 0.2 mg/kg < 1 ug/kg < 0.2 mg/kg 1,3-Dichlorobenzene < 0.2 mg/kg < 1 ug/kg < 0.2 mg/kg 1,4-Dichlorobenzene < 0.2 mg/kg < 1 ug/kg < 0.2 mg/kg Ethylbenzene 3.6 mg/kg < 1 ug/kg 92 mg/kg Toluene 2.4 mg/kg < 1 ug/kg 76 mg/kg Xylenes 12.5 mg/kg < 1 ug/kg 148 mg/kg 08/29/89 - 3 - [redacted] DATE REPORTED LABORATORY DIRECTOR Page 51 of 126
Full-size scan of page 51 (opens in a new tab)In the PDF: page 51 (opens in a new tab)
The scanned page Machine-read text
REDACTED The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-038 Attachment 4 REDACTED Page 51 of 126 CONN LIGHT & POWER CO. NORTHEAST UTILITIES WORK ORDER SKETCH SHEET SHEET ___ OF ___
SKETCH INDICATE NORTH AND NAME STREETS NOT TO SCALE DUCK HOLE RD. H8 362' 857' 76' GEN. 850' 13' E5 811' D4 G7 GARAGE 67' 850' 5' C3 42' 910' F6 B2 A1 11' 14' NEW RD. OP4185 REV. 10-82 DEST. SAME AS ATT. REC. DRAWN BY | TELEPHONE EXT.DISTRICT / REGION TOWN DATE MAP NO. WORK ORDER NO. ACTV. MADISON / EASTERN MADISON Page 52 of 126
Full-size scan of page 52 (opens in a new tab)In the PDF: page 52 (opens in a new tab)
The scanned page Machine-read text
The Connecticut Light and Power Company REDACTED d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-038 Attachment 4 REDACTED Page 52 of 126 [illegible]ETRONICS INC. ENVIRONMENTAL MONITORING SERVICE 2019 JOHN FITCH BLVD. • SOUTH WIN[redacted] [phone removed] Connecticut Light & Power P.O. Box 5017 Hartford, [illegible] 06102-5017 Attn: Mr. [redacted] RE: Test Number: 900815 Test Date: August 15, 1990 Location: Northeast Utilities 135 New Road Madison, CT [redacted] August 17, 1990 Dear Mr. [redacted] A tank integrity test was performed on the storage tanks at the above location using the LEAK COMPUTER(R) Tank Test System. This test was performed in accordance with the precision test requirements of NFPA-329-87. The criteria for acceptable tank integrity allowed by this test procedure is based upon a leak rate detection limit of +/- 0.05 gallons per hour. The results of the test are given on the attached chart. This chart identifies the tank tested, the size of the tank, the leak rate levels and a pass/fail indicator. The pass/fail indication is shown for the tank; the tank piping (risers, vent lines, etc.); and product lines, if applicable. Also included for your review is a copy of the computer printout of the test data indicating the average leak rate and the confidence level. This information will be stored in a permanent file at our office should future verification be needed to confirm the tank integrity at the time of the test. Sincerely, [illegible] Brian Reed Field Test Engineer Certification #A/P 011Page 53 of 126
Full-size scan of page 53 (opens in a new tab)In the PDF: page 53 (opens in a new tab)
The scanned page Machine-read text
The Connecticut Light and Power Company REDACTED d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-038 Attachment 4 REDACTED Page 53 of 126 PETRONICS INC. ENVIRONMENTAL MONITORING SERVICE 2019 JOHN FITCH BLVD. • SOUTH WINDSOR, CT 06074 [phone removed] TEST RESULTS Test Number: 900815 Test Date: August 15, 1990 Location: Northeast Utilities 135 New Road Madison, CTGrade Volume (gal) Low Level Leak Rate (gal/hour) High Level Leak Rate (gal/hour) Tank Tank Piping Product Lines UNLEADED TANK #2 5000 0.03 0.02 PASS PASS PASS Page 54 of 126
Full-size scan of page 54 (opens in a new tab)In the PDF: page 54 (opens in a new tab)
The scanned page Machine-read text
The Connecticut Light and Power Company REDACTED d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-038 Attachment 4 REDACTED Page 54 of 126 :P CHART FOR DATA RECORD: 90081556.A07 OF 5000 GALLON UNLEADED 2 TANK : Address: CL+P 135 NEW ROAD MADISON. CT. : Operator: BER < RATE AVG OF 30 CYCLES TANK TEMP @ START: 76.3 F 0.000662 DEN: 0.738 LFD: 6.0 Manifolding: None <----------------------- @ = 10.0F ------------------> AVG THREE <------------------------t = 0.1 F ------------------> LEAK STD GAL <----------------------- V = 0.1 gal ------------------> RATE DEV [illegible] END OF STRIP CHART DATA COLLECTED ON LEAK COMPUTER SN 88060161Page 55 of 126
Full-size scan of page 55 (opens in a new tab)In the PDF: page 55 (opens in a new tab)
The scanned page Machine-read text
REDACTED The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-038 Attachment 4 REDACTED Page 55 of 126 CATION
STATE OF CONNECTICUT Department of Environmental Protection UNDERGROUND STORAGE FACILITIES PROGRAM HAZARDOUS MATERIALS MANAGEMENT UNIT 165 Capitol Avenue, Hartford, CT 06106 TEL. 566-4630 EPHM-6 NEW 10/85 PLEASE TYPE. ALL THREE COPIES MUST BE LEGIBLE! Refer to INSTRUCTIONS FOR FILING NOTIFICATION before completing form.2. PG. OF 1 1
1a. FIRST NOTIFICATION OR b. SUBSEQUENT NOTIFICATION (If checked, enter No.) [X] SITE ID.3. FOR STATE AGENCY USE ONLY A. SITE I.D. B. DATE RCVD BY D.E.P C. DATE ENTERED D. GRID COORDINATES X ___ Y ___ E. DOES FACILITY MEET NEW REQUIREMENTS? YES NO
20. HAVE YOU ATTACHED SKETCH OF TANKS AND LOCATION? [X] YES 21. COMMENTS: All Tanks - 1&6-1&9 - Impressed Current System G7 Tank - Tank is Vaulted. 22. CERTIFICATION: I certify under penalty of law that I have personally examined and am familiar with the information submitted in this and all attached documents and that based on my inquiry of those individuals immediately responsible for obtaining the information, I believe that the submitted information is true, accurate and complete. Penalties: any owner who knowingly fails to notify shall be subject to a civil penalty not to exceed $10,000 for each tank for which notification is not given or for which false information is submitted. 22a. SIGNATURE [redacted] 22b. DATE SIGNED Oct 16, 2010 22d. OFFICIAL TITLE (of owner or authorized representative) Vice President COPY 3: RETAIN FOR YOUR RECORDS4. LOCATION OF FACILITY SITE NAME NO. AND STREET NEAREST INTERSECTING STREET CITY OR TOWN STATE LATITUDE LONGITUDE Madison Regional Service Center 105 New Rd Dick Hole Rd Madison CT 6. BUSINESS NAME AND MAILING ADDRESS NAME NO. AND STREET CITY OR TOWN STATE ZIP CODE TELEPHONE 7. FACILITY OWNER NAME: The Connecticut Light & Power Co. NO. AND STREET: P.O. Box 270 CITY OR TOWN: Hartford STATE: CT ZIP CODE: 06141-0270 [redacted] 8. TYPE OF OWNER PRIVATE STATE MUNICIPAL FEDERAL (G.S.A. No. ___) 9. OPERATOR/CONTACT PERSON NAME [redacted] NO. AND STREET: 105 New Rd CITY OR TOWN: Madison STATE: CT ZIP CODE: 06443 TELEPHONE [redacted] 10. TANK ID 11a. DATE OF INSTALLATION (Mo./Yr.) 11b. LIFE EXPECTANCY (# of years) 12a. TOTAL CAPACITY (Gals.) IN USE ABANDONED IN PLACE 12b. STATUS EST. QUANTITY LEFT STORED (if any) (Gals.) REMOVED DATE TANK LAST USED (Mo./Yr.) 13. TYPE OF CONTENTS OIL/PETRO-LEUM PRODUCT CHEMICAL LIQUID 14. CONTENTS CHEMICAL NAME OF PRINCIPAL SUBSTANCE (not trade name.) (Enter C.A.S. No., If known) 15. CONSTRUCTION MATERIALS STEEL FIBERGLASS REINFORCED PLASTIC OTHER (Specify from list A) a. INTERNAL LINED UNLINED 16. PROTECTION a. INTERNAL CATHODIC PROTECTION COATED/WRAPPED b. EXTERNAL CATHODIC PROTECTION OTHER (Specify from list B) 17. INTEGRAL PIPING SYSTEM a. CONSTRUCTION AND PROTECTION (See list A&B) b. DATE OF INSTALLATION OR REPLACEMENT (Mo./Yr.) MONITORING SYSTEM (Specify type from list B) DETERMINATION CONDUCTED? (If "YES", enter DATE and attach results. If "NO", enter "NO") Example 5/75 30 5000 X X X X H 5 5/75 U NO Example 7/60 - 8000 X 8/78 X X X E 7 7/60 U - A1 /73 20 550 X X X X E 8 /73 IO NO B2 /73 30 550 X X X X E 8 /73 IO NO C3 /73 20 5000 X X UNLEADED GASOLINE X X EA 8C 10/89 IO 9-15-90 D4 /73 20 5000 X X UNLEADED GASOLINE X X EA 8C 10/89 IO 7-?-90 E5 /73 - 10000 X 8/89 X UNLEADED GASOLINE X X I F6 /73 20 550 X X WASTE OIL X X E 8 /73 I NO G7 /73 20 170 X X HYDRAULIC OIL X X EE 8C /73 R NO H8 /73 - 1500 X /89 X DIESEL NO Page 56 of 126
Full-size scan of page 56 (opens in a new tab)In the PDF: page 56 (opens in a new tab)
The scanned page Machine-read text
REDACTED The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Date Issued September 29, 2026 RSR-038 Attachment 4 REDACTED Page 56 of 126 FACILITY NOTIFICATION 1a. FIRST NOTIFICATION OR b. SUBSEQUENT NOTIFICATION (If checked, enter No.) SITE I.D. UNDERGROUND STORAGE FACILITIES PROGRAM HAZARDOUS MATERIALS MANAGEMENT UNIT 165 Capitol Avenue, Hartford, CT 06106 TEL. 566-4630 PLEASE TYPE. ALL THREE COPIES MUST BE LEGIBLE! Refer to INSTRUCTIONS FOR FILING NOTIFICATION before completing form. FOR STATE AGENCY USE ONLY B. DATE RCVD BY D.E.P | C. DATE ENTERED D. GRID COORDINATES X ___ Y ___ E. DOES FACILITY MEET NEW REQUIREMENTS? ☐ YES ☐ NO SECTION A
SECTION B4. LOCATION OF FACILITY SITE NAME: MADISON REGIONAL SERVICE CENTER NO. AND STREET: 135 NEW RD NEAREST INTERSECTING STREET: DUCK HOLE RD CITY OR TOWN: MADISON STATE: CT 5. LATITUDE LONGITUDE 6. BUSINESS NAME AND MAILING ADDRESS NAME NO. AND STREET CITY OR TOWN STATE ZIP CODE TELEPHONE
SECTION C7. FACILITY OWNER NAME: THE CONNECTICUT LIGHT & POWER CO. NO. AND STREET: P.O. BOX 270 CITY OR TOWN: HARTFORD STATE: CT ZIP CODE: 06141-0270 [redacted] 8. TYPE OF OWNER ☐ PRIVATE ☐ STATE ☐ MUNICIPAL ☐ FEDERAL (G.S.A. No. ___) 9. OPERATOR/CONTACT PERSON NAME: [redacted] NO. AND STREET: 135 NEW RD CITY OR TOWN: MADISON STATE: CT ZIP CODE: 06443
HYDRAULIC FLUID B2 | /73 | 30 | 550 | X | | | | X | | | X | | X | E | 8 | /73 | IO | NO MOTOR OIL C3 | /73 | 30 | 5000 | X | | | | X | | | X | | X | EA | 8C | 10/89 | IO | 8-15-90 UNLEADED GASOLINE D4 | /73 | 30 | 5000 | X | | | | X | | | X | | X | EA | 8C | 10/89 | IO | 7-24-90 UNLEADED GASOLINE E5 | /73 | – | 10000 | | | | X 8/89 | X | | | | | | | | | | UNLEADED GASOLINE F6 | /73 | 30 | 550 | X | | | | X | | | X | | X | E | 8 | /73 | I | NO WASTE OIL G7 | /73 | 30 | 170 | X | | | | X | | | X | | X | EF | 8C | /73 | R | NO HYDRAULIC OIL H8 | /73 | – | 1500 | | | | X /89 | X | | | | | | | | | | DIESEL SECTION D 20. HAVE YOU ATTACHED SKETCH OF TANKS AND LOCATION? ☒ YES 21. COMMENTS: All Tanks - 16b+17a- Impressed Current System G7-16b- Tank is vaulted. 22. CERTIFICATION: I certify under penalty of law that I have personally examined and am familiar with the information submitted in this and all attached documents and that based on my inquiry of those individuals immediately responsible for obtaining the information, I believe that the submitted information is true, accurate and complete. Penalties: any owner who knowingly fails to notify shall be subject to a civil penalty not to exceed $10,000 for each tank for which notification is not given or for which false information is submitted. [redacted] 22a. DATE SIGNED: Oct. 16, 1990 22d. OFFICIAL TITLE (of owner or authorized representative): Vice President COPY 1: SEND TO DEP: 165 CAPITOL AVE. HART[redacted]10. TANK ID 11a. DATE OF INSTALLATION (Mo./Yr.) LIFE EXPECTANCY (# of years) TOTAL CAPACITY (Gals.) STATUS: IN USE ABANDONED IN PLACE EST. QUANTITY LEFT STORED (if any.) (Gals.) REMOVED DATE TANK LAST USED (Mo./Yr.) 13. TYPE OF CONTENTS: OIL/PETROLEUM PRODUCT CHEMICAL LIQUID 14. CONTENTS - CHEMICAL NAME OF PRINCIPAL SUBSTANCE (not trade name.) (Enter C.A.S. No., if known) 15. CONSTRUCTION MATERIALS: STEEL FIBERGLASS REINFORCED PLASTIC OTHER (Specify from list A) 16. PROTECTION a. INTERNAL: LINED UNLINED CATHODIC PROTECTION COATED/WRAPPED b. EXTERNAL: CATHODIC PROTECTION OTHER (Specify from list B) 17. INTEGRAL PIPING SYSTEM a. CONSTRUCTION (see list A8) b. DATE OF INSTALLATION OR REPLACEMENT (Mo./Yr.) MONITORING SYSTEM (Specify type from list B) 18. DETERMINATION CONDUCTED? (If "YES", enter DATE and attach results). (If "NO", enter "NO") Example 5/75 30 5000 X X X H 5 5/75 U NO Heating fuel #2 X (fiberglass) X (unlined) Example 7/60 – 8000 X 8/78 X X E 7 7/60 U – 1,1,1 - Trichloroethane CAS #79016 X (steel) X (unlined) A1 /73 30 550 X X X X E 8 /73 IO NO
As listed on the current system
Question(s) Answered 38 (The Connecticut Light and Power Company) Date Filed: 10/20/2026