Interrogatory responses
Answers to questions 2, 3, 5, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20
Files24
UCONN-002_Final.pdf
PDF · 110 KB · 1 pageText searchable
Download UCONN-002_Final.pdfRead the text of UCONN-002_Final.pdf
UCONN-003_Final.pdf
PDF · 87 KB · 1 pageText searchable
Download UCONN-003_Final.pdfRead the text of UCONN-003_Final.pdf
UCONN-005_Final.pdf
PDF · 88 KB · 1 pageText searchable
Download UCONN-005_Final.pdfRead the text of UCONN-005_Final.pdf
UCONN-005 Attachment 1.pdf
PDF · 135 KB · 1 pageText searchable
Download UCONN-005 Attachment 1.pdfRead the text of UCONN-005 Attachment 1.pdf
UCONN-005 Attachment 1.xlsx
Excel · 25 KBText searchable
Download UCONN-005 Attachment 1.xlsxRead the text of UCONN-005 Attachment 1.xlsx
UCONN-008_Final.pdf
PDF · 116 KB · 2 pagesText searchable
Download UCONN-008_Final.pdfRead the text of UCONN-008_Final.pdf
UCONN-008 Attachment 1.pdf
PDF · 201 KB · 4 pagesText searchable
Download UCONN-008 Attachment 1.pdfRead the text of UCONN-008 Attachment 1.pdf
UCONN-008 Attachment 1.xlsx
Excel · 50 KBText searchable
Download UCONN-008 Attachment 1.xlsxRead the text of UCONN-008 Attachment 1.xlsx
UCONN-009_Final.pdf
PDF · 113 KB · 2 pagesText searchable
Download UCONN-009_Final.pdfRead the text of UCONN-009_Final.pdf
UCONN-009 Attachment 1.pdf
PDF · 290 KB · 5 pagesText searchable
Download UCONN-009 Attachment 1.pdfRead the text of UCONN-009 Attachment 1.pdf
UCONN-009 Attachment 1.xlsx
Excel · 47 KBText searchable
Download UCONN-009 Attachment 1.xlsxRead the text of UCONN-009 Attachment 1.xlsx
UCONN-010_Final.pdf
PDF · 121 KB · 2 pagesText searchable
Download UCONN-010_Final.pdfRead the text of UCONN-010_Final.pdf
UCONN-011_Final.pdf
PDF · 92 KB · 1 pageText searchable
Download UCONN-011_Final.pdfRead the text of UCONN-011_Final.pdf
UCONN-012_Final.pdf
PDF · 138 KB · 2 pagesText searchable
Download UCONN-012_Final.pdfRead the text of UCONN-012_Final.pdf
UCONN-013_Final.pdf
PDF · 169 KB · 3 pagesText searchable
Download UCONN-013_Final.pdfRead the text of UCONN-013_Final.pdf
UCONN-014_Final.pdf
PDF · 113 KB · 2 pagesText searchable
Download UCONN-014_Final.pdfRead the text of UCONN-014_Final.pdf
UCONN-015_Final.pdf
PDF · 120 KB · 2 pagesText searchable
Download UCONN-015_Final.pdfRead the text of UCONN-015_Final.pdf
UCONN-016_Final.pdf
PDF · 161 KB · 1 pageText searchable
Download UCONN-016_Final.pdfRead the text of UCONN-016_Final.pdf
UCONN-017_Final.pdf
PDF · 133 KB · 2 pagesText searchable
Download UCONN-017_Final.pdfRead the text of UCONN-017_Final.pdf
UCONN-018_Final.pdf
PDF · 133 KB · 2 pagesText searchable
Download UCONN-018_Final.pdfRead the text of UCONN-018_Final.pdf
UCONN-019_Final.pdf
PDF · 358 KB · 15 pagesText searchable
Download UCONN-019_Final.pdfRead the text of UCONN-019_Final.pdf
UCONN-019 Attachment 1.pdf
PDF · 121 KB · 1 pageText searchable
Download UCONN-019 Attachment 1.pdfRead the text of UCONN-019 Attachment 1.pdf
UCONN-019 Attachment 1.xlsx
Excel · 27 KBText searchable
Download UCONN-019 Attachment 1.xlsxRead the text of UCONN-019 Attachment 1.xlsx
UCONN-020_Final.pdf
PDF · 109 KB · 2 pagesText searchable
Download UCONN-020_Final.pdfRead the text of UCONN-020_Final.pdf
Text of UCONN-005 Attachment 1.pdf
Extracted from the file · 1 page · 1,205 characters
Text of UCONN-005 Attachment 1.xlsx
Sheet names, column headings and text cells; numbers left out
Text of UCONN-008_Final.pdf
Extracted from the file · 2 pages · 5,771 characters
Text of UCONN-008 Attachment 1.pdf
Extracted from the file · 4 pages · 3,435 characters
Text of UCONN-008 Attachment 1.xlsx
Sheet names, column headings and text cells; numbers left out
Text of UCONN-009_Final.pdf
Extracted from the file · 2 pages · 4,198 characters
Text of UCONN-009 Attachment 1.pdf
Extracted from the file · 5 pages · 2,765 characters
Text of UCONN-009 Attachment 1.xlsx
Sheet names, column headings and text cells; numbers left out
Text of UCONN-010_Final.pdf
Extracted from the file · 2 pages · 5,414 characters
Page 1
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Set UCONN-01 Date Issued September 18, 2026 UCONN-011 Page 1 of 1 Date Filed: October 02, 2026 Witness: Edward A. Davis and Kimberly R. Parsons Request from: UCONN Question: (Rate Design & Tariff Structure) Refer to Exhibit CLP-RATES-1 at p. 37. Consistent with established regulatory principles, Rate 6 is “designed first and foremost to benefit ratepayers through improved system economics and affordability, while also supporting broader climate change objectives.” Does Eversource agree that DER adoption and operation by its intermediate and large commercial customers to reduce a customer’s grid demand during hours of peak demand on Eversource’s transmission and distribution system can benefit other ratepayers through improved system economics and affordability? Response: No, not necessarily. As a first matter, the reason that the Company’s proposed heat pump rate improves system economics and affordability for the residential customer, is that the rate is designed to promote the use of the system during the winter months when there is relatively lower consumption on the electric system. This proposition does not simply translate to the proposition that DER adoption reducing a customer’s grid demand on peak will equally benefit other customers with “improved system economics and affordability.” From a distribution system operator perspective, DER adoption and operation by an intermediate or large commercial customer that reduces the respective customer’s grid demand during hours of peak demand does not help the system, unless the system is relieved of any capacity requirements for that respective customer during the peak – meaning that the customer would have no back-up source of power on peak. The distribution system is constructed to meet the requirements of localized peak demands and if one or more customers is able to take their load off-line, it benefits that customer. It benefits other customers, only if the Company is actually able to avoid the need for capacity on the system, which can only occur if the customer benefiting from DER is willing to relieve the system of an obligation to provide firm service upon demand for the single customer. From an ISO-NE perspective, reduced demand is a benefit in a supply-constrained market. However, from a distribution system perspective, capacity requirements are not relieved when individual customers take advantage of DER to improve their own economic proposition so long as there is an expectation that the distribution system can support all loads with or without the DER alternatives for specific customers.
Text of UCONN-012_Final.pdf
Extracted from the file · 2 pages · 2,655 characters
Text of UCONN-013_Final.pdf
Extracted from the file · 3 pages · 7,147 characters
Text of UCONN-014_Final.pdf
Extracted from the file · 2 pages · 3,231 characters
Text of UCONN-015_Final.pdf
Extracted from the file · 2 pages · 2,786 characters
Text of UCONN-016_Final.pdf
Extracted from the file · 1 page · 1,594 characters
Text of UCONN-017_Final.pdf
Extracted from the file · 2 pages · 4,370 characters
Text of UCONN-018_Final.pdf
Extracted from the file · 2 pages · 4,887 characters
Text of UCONN-019_Final.pdf
Extracted from the file · 15 pages · 48,353 characters
Text of UCONN-019 Attachment 1.pdf
Extracted from the file · 1 page · 2,251 characters
Text of UCONN-019 Attachment 1.xlsx
Sheet names, column headings and text cells; numbers left out
Text of UCONN-020_Final.pdf
Extracted from the file · 2 pages · 4,145 characters
As listed on the current system
Question(s) Answered 2, 3, 5, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20 (The Connecticut Light and Power Company) Date Filed: 10/02/2026